-- SML MIB Rev 1.21
|
||
|
-- Added subChassisGroup to support multiple Chassis.
|
||
|
-- SML MIB Rev 1.20
|
||
|
-- Added trapGroup and *Alert traps.
|
||
|
-- Deprecated mediaAccessDevice-Status in favor of
|
||
|
-- mediaAccessDevice-operationalStatus to be consistent
|
||
|
-- with other Groups.
|
||
|
-- Fixed some typos in scsiProtocolControllerGroup,
|
||
|
-- limitedAccessPortGroup, storageMediaLocationGroup,
|
||
|
-- and fcPortGroup Description fields.
|
||
|
-- Add EOLs throughout to hard-wrap to 80 char display.
|
||
|
-- SML MIB Rev 1.19
|
||
|
-- Added fCPortGroup
|
||
|
-- Fixed OperationalStatus enumeration to match CIM 2.9.1 and
|
||
|
-- include a value for stopped and VendorReserved
|
||
|
-- Fixed SecurityBreach to match the MOF
|
||
|
-- SML MIB Rev 1.18
|
||
|
-- Changed physicalMedia to be flat under storageMediaLocation to allow
|
||
|
-- operation with MIB compilers
|
||
|
-- Broke compatibility with 1.16
|
||
|
-- SML MIB Rev 1.16
|
||
|
-- Updated to comply with CIM 2.8 and SMI-S 1.1
|
||
|
-- Added storageMediaLocation, changerDevice, limitedAccessPort,
|
||
|
-- scsiProtocolController, computerSystem
|
||
|
--
|
||
|
-- Art Colvig
|
||
|
-- IBM
|
||
|
-- SML MIB Rev 1.12
|
||
|
-- ASN.1 code created using dot2asn
|
||
|
-- by Jeff Bain
|
||
|
-- Hewlett Packard, Storage Systems Division
|
||
|
-- Greeley, CO
|
||
|
-- jeff_bain@hp.com
|
||
|
-- Michael Kearney
|
||
|
-- Qualstar
|
||
|
-- mkearney@qualstar-boulder.com
|
||
|
|
||
|
SNIA-SML-MIB
|
||
|
DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
OBJECT-TYPE
|
||
|
FROM RFC-1212
|
||
|
enterprises
|
||
|
FROM RFC1155-SMI
|
||
|
DisplayString
|
||
|
FROM RFC1213-MIB
|
||
|
;
|
||
|
|
||
|
-- Textual Conventions
|
||
|
|
||
|
UShortReal ::= INTEGER (0..'ffff'h)
|
||
|
-- This textual convention can be used to represent short
|
||
|
-- unsigned 'real' numbers. Using this variable type,
|
||
|
-- a 3 digit number with 2 decimal places (xxx.xx)
|
||
|
-- can be represented. For example, 321.45 would be
|
||
|
-- represented as "32145"
|
||
|
|
||
|
CimDateTime ::= OCTET STRING (SIZE (24))
|
||
|
-- This textual convention can be used to represent a date
|
||
|
-- and time using the CIM DateTime convention. The bytes are
|
||
|
-- as follows:
|
||
|
|
||
|
-- octets contents range
|
||
|
-- ====== ======== =====
|
||
|
-- 1-4 year 0000-9999
|
||
|
-- 5-6 month 01-12
|
||
|
-- 7-8 day 01-31
|
||
|
-- 9-10 hour 00-23
|
||
|
-- 11-12 minute 00-59
|
||
|
-- 13-14 second 00-59
|
||
|
-- 15-20 microseconds 000000-999999
|
||
|
-- 21 sign '+' or '-'
|
||
|
-- 22-24 UTC offset in minutes 000-839
|
||
|
|
||
|
-- For example, Monday, May 25, 1998, at 1:30:15 PM EST would be
|
||
|
-- represented as 19980525133015000000-300
|
||
|
|
||
|
-- Note that values must be zero-padded so that the entire
|
||
|
-- string is always the same 25-character length. Fields that
|
||
|
-- are not significant can be replaced with asterisk characters
|
||
|
|
||
|
UINT64 ::= OCTET STRING (SIZE (8))
|
||
|
-- This textual convention can be used to represent 64-bit
|
||
|
-- numbers using the OCTET STRING type. SNMPv2 supports a
|
||
|
-- Counter64 type, but there is no C-language mapping for a
|
||
|
-- 64-bit variable that's much better than an array of 8 bytes
|
||
|
|
||
|
UINT32 ::= INTEGER (0..'7fffffff'h)
|
||
|
UINT16 ::= INTEGER (0..'ffff'h)
|
||
|
-- MIB Fields
|
||
|
snia OBJECT IDENTIFIER ::= { enterprises 14851 }
|
||
|
|
||
|
experimental OBJECT IDENTIFIER ::= { snia 1 }
|
||
|
|
||
|
common OBJECT IDENTIFIER ::= { snia 2 }
|
||
|
|
||
|
libraries OBJECT IDENTIFIER ::= { snia 3 }
|
||
|
|
||
|
|
||
|
smlRoot OBJECT IDENTIFIER ::= { libraries 1 }
|
||
|
|
||
|
|
||
|
smlMibVersion OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 4 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This string contains version information for the MIB file"
|
||
|
::= { smlRoot 1 }
|
||
|
|
||
|
smlCimVersion OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 4 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This string contains information about the
|
||
|
CIM version that corresponds to the MIB.
|
||
|
The decriptions in this MIB file are based on CIM version 2.8"
|
||
|
::= { smlRoot 2 }
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
productGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 3 }
|
||
|
|
||
|
product-Name OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Commonly used Product name."
|
||
|
::= { productGroup 1 }
|
||
|
|
||
|
product-IdentifyingNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Product identification such as a serial number on
|
||
|
software, a die number on a hardware chip, or (for
|
||
|
non-commercial Products) a project number."
|
||
|
::= { productGroup 2 }
|
||
|
|
||
|
product-Vendor OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The name of the Product's supplier, or entity
|
||
|
selling the Product (the manufacturer, reseller, OEM, etc.).
|
||
|
Corresponds to the Vendor property in the Product object
|
||
|
in the DMTF Solution Exchange Standard."
|
||
|
::= { productGroup 3 }
|
||
|
|
||
|
product-Version OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Product version information. Corresponds to the
|
||
|
Version property in the Product object in the DMTF Solution
|
||
|
Exchange Standard."
|
||
|
::= { productGroup 4 }
|
||
|
|
||
|
product-ElementName OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A user-friendly name for the object. This property
|
||
|
allows each instance to define a user-friendly name IN
|
||
|
ADDITION TO its key properties/identity data, and
|
||
|
description information.
|
||
|
Note that ManagedSystemElement's Name property is also
|
||
|
defined as a user-friendly name. But, it is often
|
||
|
subclassed to be a Key. It is not reasonable that the same
|
||
|
property can convey both identity and a user friendly name,
|
||
|
without inconsistencies. Where Name exists and is not a Key
|
||
|
(such as for instances of LogicalDevice), the same
|
||
|
information MAY be present in both the Name and ElementName
|
||
|
properties."
|
||
|
::= { productGroup 5 }
|
||
|
|
||
|
|
||
|
|
||
|
chassisGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 4 }
|
||
|
|
||
|
chassis-Manufacturer OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The name of the organization responsible for
|
||
|
producing the PhysicalElement. This may be the entity from
|
||
|
whom the Element is purchased, but this is not
|
||
|
necessarily true. The latter information is contained in
|
||
|
the Vendor property
|
||
|
of CIM_Product."
|
||
|
::= { chassisGroup 1 }
|
||
|
|
||
|
chassis-Model OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The name by which the PhysicalElement is generally known."
|
||
|
::= { chassisGroup 2 }
|
||
|
|
||
|
chassis-SerialNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A manufacturer-allocated number used to identify the Physical Element."
|
||
|
::= { chassisGroup 3 }
|
||
|
|
||
|
chassis-LockPresent OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Boolean indicating whether the Frame is protected with a lock."
|
||
|
::= { chassisGroup 4 }
|
||
|
|
||
|
chassis-SecurityBreach OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (1),
|
||
|
other (2),
|
||
|
noBreach (3),
|
||
|
breachAttempted (4),
|
||
|
breachSuccessful (5) }
|
||
|
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"SecurityBreach is an enumerated, integer-valued
|
||
|
property indicating whether a physical breach of the Frame
|
||
|
was attempted but unsuccessful (value=4) or attempted and
|
||
|
successful (5). Also, the values, 'Unknown', 'Other' or 'No
|
||
|
Breach', can be specified."
|
||
|
::= { chassisGroup 5 }
|
||
|
|
||
|
chassis-IsLocked OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Boolean indicating that the Frame is currently locked."
|
||
|
::= { chassisGroup 6 }
|
||
|
|
||
|
chassis-Tag OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An arbitrary string that uniquely identifies the
|
||
|
Physical Element and serves as the Element's key. The Tag
|
||
|
property can contain information such as asset tag or serial
|
||
|
number data. The key for PhysicalElement is placed very high in
|
||
|
the object hierarchy in order to independently identify the
|
||
|
hardware/entity, regardless of physical placement in or on
|
||
|
Cabinets, Adapters, etc. For example, a hotswappable or
|
||
|
removeable component may be taken from its containing
|
||
|
(scoping) Package and be temporarily unused. The object
|
||
|
still continues to exist - and may even be inserted into a
|
||
|
different scoping container. Therefore, the key for
|
||
|
Physical Element is an arbitrary string and is defined
|
||
|
independently of any placement or location-oriented
|
||
|
hierarchy."
|
||
|
::= { chassisGroup 7 }
|
||
|
|
||
|
chassis-ElementName OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A user-friendly name for the object. This property
|
||
|
allows each instance to define a user-friendly name IN
|
||
|
ADDITION TO its key properties/identity data, and description
|
||
|
information.
|
||
|
Note that ManagedSystemElement's Name property is also
|
||
|
defined as a user-friendly name. But, it is often
|
||
|
subclassed to be a Key. It is not reasonable that the same
|
||
|
property can convey both identity and a user friendly name,
|
||
|
without inconsistencies. Where Name exists and is not a Key
|
||
|
(such as for instances of LogicalDevice), the same
|
||
|
information MAY be present in both the Name and ElementName
|
||
|
properties."
|
||
|
::= { chassisGroup 8 }
|
||
|
|
||
|
|
||
|
numberOfsubChassis OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the number of sub Chassis that are
|
||
|
present."
|
||
|
::= { chassisGroup 9 }
|
||
|
|
||
|
subChassisTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SubChassis-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The SubChassis class represents the physical frames in the library"
|
||
|
::= { chassisGroup 10 }
|
||
|
|
||
|
subChassisEntry OBJECT-TYPE
|
||
|
SYNTAX SubChassis-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Each entry in the table contains information about a
|
||
|
frame that is present in the library."
|
||
|
INDEX { subChassisIndex }
|
||
|
::= { subChassisTable 1 }
|
||
|
|
||
|
SubChassis-Table-Info ::= SEQUENCE {
|
||
|
subChassisIndex UINT32,
|
||
|
subChassis-Manufacturer DisplayString,
|
||
|
subChassis-Model DisplayString,
|
||
|
subChassis-SerialNumber DisplayString,
|
||
|
subChassis-LockPresent INTEGER,
|
||
|
subChassis-SecurityBreach INTEGER,
|
||
|
subChassis-IsLocked INTEGER,
|
||
|
subChassis-Tag DisplayString,
|
||
|
subChassis-ElementName DisplayString,
|
||
|
subChassis-OperationalStatus INTEGER,
|
||
|
subChassis-PackageType INTEGER
|
||
|
}
|
||
|
|
||
|
subChassisIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the subChassis."
|
||
|
::= { subChassisEntry 1 }
|
||
|
|
||
|
subChassis-Manufacturer OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The name of the organization responsible for
|
||
|
producing the PhysicalElement. This may be the entity from
|
||
|
whom the Element is purchased, but this is not
|
||
|
necessarily true. The latter information is contained in
|
||
|
the Vendor property
|
||
|
of CIM_Product."
|
||
|
::= { subChassisEntry 2 }
|
||
|
|
||
|
subChassis-Model OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The name by which the PhysicalElement is generally known."
|
||
|
::= { subChassisEntry 3 }
|
||
|
|
||
|
subChassis-SerialNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A manufacturer-allocated number used to identify the Physical Element."
|
||
|
::= { subChassisEntry 4 }
|
||
|
|
||
|
subChassis-LockPresent OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Boolean indicating whether the Frame is protected with a lock."
|
||
|
::= { subChassisEntry 5 }
|
||
|
|
||
|
subChassis-SecurityBreach OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (1),
|
||
|
other (2),
|
||
|
noBreach (3),
|
||
|
breachAttempted (4),
|
||
|
breachSuccessful (5) }
|
||
|
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"SecurityBreach is an enumerated, integer-valued
|
||
|
property indicating whether a physical breach of the Frame
|
||
|
was attempted but unsuccessful (value=4) or attempted and
|
||
|
successful (5). Also, the values, 'Unknown', 'Other' or 'No
|
||
|
Breach', can be specified."
|
||
|
::= { subChassisEntry 6 }
|
||
|
|
||
|
subChassis-IsLocked OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Boolean indicating that the Frame is currently locked."
|
||
|
::= { subChassisEntry 7 }
|
||
|
|
||
|
subChassis-Tag OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An arbitrary string that uniquely identifies the
|
||
|
Physical Element and serves as the Element's key. The Tag
|
||
|
property can contain information such as asset tag or serial
|
||
|
number data. The key for PhysicalElement is placed very high in
|
||
|
the object hierarchy in order to independently identify the
|
||
|
hardware/entity, regardless of physical placement in or on
|
||
|
Cabinets, Adapters, etc. For example, a hotswappable or
|
||
|
removeable component may be taken from its containing
|
||
|
(scoping) Package and be temporarily unused. The object
|
||
|
still continues to exist - and may even be inserted into a
|
||
|
different scoping container. Therefore, the key for
|
||
|
Physical Element is an arbitrary string and is defined
|
||
|
independently of any placement or location-oriented
|
||
|
hierarchy."
|
||
|
::= { subChassisEntry 8 }
|
||
|
|
||
|
subChassis-ElementName OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A user-friendly name for the object. This property
|
||
|
allows each instance to define a user-friendly name IN
|
||
|
ADDITION TO its key properties/identity data, and description
|
||
|
information.
|
||
|
Note that ManagedSystemElement's Name property is also
|
||
|
defined as a user-friendly name. But, it is often
|
||
|
subclassed to be a Key. It is not reasonable that the same
|
||
|
property can convey both identity and a user friendly name,
|
||
|
without inconsistencies. Where Name exists and is not a Key
|
||
|
(such as for instances of LogicalDevice), the same
|
||
|
information MAY be present in both the Name and ElementName
|
||
|
properties."
|
||
|
::= { subChassisEntry 9 }
|
||
|
|
||
|
subChassis-OperationalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { unknown (0),
|
||
|
other (1),
|
||
|
ok (2),
|
||
|
degraded (3),
|
||
|
stressed (4),
|
||
|
predictiveFailure (5),
|
||
|
error (6),
|
||
|
non-RecoverableError (7),
|
||
|
starting (8),
|
||
|
stopping (9),
|
||
|
stopped (10),
|
||
|
inService (11),
|
||
|
noContact (12),
|
||
|
lostCommunication (13),
|
||
|
aborted (14),
|
||
|
dormant (15),
|
||
|
supportingEntityInError (16),
|
||
|
completed (17),
|
||
|
powerMode (18),
|
||
|
dMTFReserved (19),
|
||
|
vendorReserved (32768) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Indicates the current status(es) of the element.
|
||
|
Various health and operational statuses are defined. Many of
|
||
|
the enumeration's values are self- explanatory. However, a few
|
||
|
are not and are described in more detail. \n
|
||
|
'Stressed' indicates that the element is functioning, but
|
||
|
needs attention. Examples of 'Stressed' states are
|
||
|
overload, overheated, etc. \n
|
||
|
'Predictive Failure' indicates that an element is
|
||
|
functioning nominally but predicting a failure in the near
|
||
|
future. \n
|
||
|
'In Service' describes an element being configured,
|
||
|
maintained, cleaned, or otherwise administered. \n
|
||
|
'No Contact' indicates that the monitoring system has
|
||
|
knowledge of this element, but has never been able to
|
||
|
establish communications with it. \n
|
||
|
'Lost Communication' indicates that the ManagedSystem
|
||
|
Element is known to exist and has been contacted
|
||
|
successfully in the past, but is currently unreachable. \n
|
||
|
'Stopped' and 'Aborted' are similar, although the
|
||
|
former implies a clean and orderly stop, while the latter
|
||
|
implies an abrupt stop where the element's state and
|
||
|
configuration may need to be updated. \n
|
||
|
'Dormant' indicates that the element is inactive or
|
||
|
quiesced. \n
|
||
|
'Supporting Entity in Error' describes that this element
|
||
|
may be 'OK' but that another element, on which it is
|
||
|
dependent, is in error. An example is a network service or
|
||
|
endpoint that cannot function due to lower layer networking
|
||
|
problems. \n
|
||
|
'Completed' indicates the element has completed its
|
||
|
operation. This value should be combined with either OK,
|
||
|
Error, or Degraded so that a client can till if the
|
||
|
complete operation passed (Completed with OK), and failure
|
||
|
(Completed with Error). Completed with Degraded would imply
|
||
|
the operation finished, but did not complete OK or report
|
||
|
an error. \n
|
||
|
'Power Mode' indicates the element has additional power
|
||
|
model information contained in the Associated
|
||
|
PowerManagementService association. \n
|
||
|
OperationalStatus replaces the Status property on
|
||
|
ManagedSystemElement to provide a consistent approach to
|
||
|
enumerations, to address implementation needs for an array
|
||
|
property, and to provide a migration path from today's
|
||
|
environment to the future. This change was not made earlier
|
||
|
since it required the DEPRECATED qualifier. Due to the
|
||
|
widespread use of the existing Status property in
|
||
|
management applications, it is strongly RECOMMENDED that
|
||
|
providers/instrumentation provide BOTH the Status and
|
||
|
OperationalStatus properties. Further, the first value of
|
||
|
OperationalStatus SHOULD contain the primary status for the
|
||
|
element. When instrumented, Status (since it is
|
||
|
single-valued) SHOULD also provide the primary status of
|
||
|
the element."
|
||
|
::= { subChassisEntry 10 }
|
||
|
|
||
|
|
||
|
subChassis-PackageType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
mainSystemChassis(17),
|
||
|
expansionChassis(18),
|
||
|
subChassis(19),
|
||
|
serviceBay(32769) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Package type of the subChassis. The enumeration values for this variable
|
||
|
should be the same as the DMTF CIM_Chassis.ChassisPackageType
|
||
|
property. Use the Vendor reserved values for vendor-specific types."
|
||
|
::= { subChassisEntry 11 }
|
||
|
|
||
|
|
||
|
storageLibraryGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 5 }
|
||
|
|
||
|
storageLibrary-Name OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The inherited Name serves as key of a System
|
||
|
instance in an enterprise environment."
|
||
|
::= { storageLibraryGroup 1 }
|
||
|
|
||
|
storageLibrary-Description OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The Description property provides a textual
|
||
|
description of the object."
|
||
|
::= { storageLibraryGroup 2 }
|
||
|
|
||
|
storageLibrary-Caption OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The Caption property is a short textual description
|
||
|
(one- line string) of the object."
|
||
|
::= { storageLibraryGroup 3 }
|
||
|
|
||
|
storageLibrary-Status OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 10 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"A string indicating the current status of the object.
|
||
|
Various operational and non-operational statuses are defined.
|
||
|
This property is deprecated in lieu of OperationalStatus, which
|
||
|
includes the same semantics in its enumeration. This change is
|
||
|
made for three reasons:
|
||
|
1) Status is more correctly defined as an array property. This
|
||
|
overcomes the limitation of describing status via a single
|
||
|
value, when it is really a multi-valued property (for example,
|
||
|
an element may be OK AND Stopped.
|
||
|
2) A MaxLen of 10 is too restrictive and leads to unclear
|
||
|
enumerated values. And,
|
||
|
3) The change to a uint16 data type was discussed when CIM V2.0
|
||
|
was defined.
|
||
|
However, existing V1.0 implementations used the string property
|
||
|
and did not want to modify their code. Therefore, Status was
|
||
|
grandfathered into the Schema. Use of the Deprecated qualifier
|
||
|
allows the maintenance of the existing property, but
|
||
|
also permits an improved definition using OperationalStatus."
|
||
|
::= { storageLibraryGroup 4 }
|
||
|
|
||
|
storageLibrary-InstallDate OBJECT-TYPE
|
||
|
SYNTAX CimDateTime
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"A datetime value indicating when the object was
|
||
|
installed. A lack of a value does not indicate that the object
|
||
|
is not installed."
|
||
|
::= { storageLibraryGroup 5 }
|
||
|
|
||
|
|
||
|
|
||
|
-- "A MediaAccessDevice represents the ability to access one or "
|
||
|
-- "more media and use this media to store and retrieve data."
|
||
|
-- class CIM_MediaAccessDevice : CIM_LogicalDevice {
|
||
|
mediaAccessDeviceGroup
|
||
|
OBJECT IDENTIFIER
|
||
|
::= { smlRoot 6 }
|
||
|
|
||
|
numberOfMediaAccessDevices OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the number of MediaAccessDevices
|
||
|
that are present."
|
||
|
::= { mediaAccessDeviceGroup 1 }
|
||
|
|
||
|
mediaAccessDeviceTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF Media-Access-Device-Table
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A MediaAccessDevice represents the ability to access one
|
||
|
or more media and use this media to store and retrieve data."
|
||
|
::= { mediaAccessDeviceGroup 2 }
|
||
|
|
||
|
mediaAccessDeviceEntry OBJECT-TYPE
|
||
|
SYNTAX Media-Access-Device-Table
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Each entry in the table contains information about a
|
||
|
MediaAccessDevice that is present in the library."
|
||
|
INDEX { mediaAccessDeviceIndex }
|
||
|
::= { mediaAccessDeviceTable 1 }
|
||
|
|
||
|
Media-Access-Device-Table ::= SEQUENCE {
|
||
|
mediaAccessDeviceIndex UINT32,
|
||
|
mediaAccessDeviceObjectType INTEGER,
|
||
|
mediaAccessDevice-Name DisplayString,
|
||
|
mediaAccessDevice-Status DisplayString,
|
||
|
mediaAccessDevice-Availability INTEGER,
|
||
|
mediaAccessDevice-NeedsCleaning INTEGER,
|
||
|
mediaAccessDevice-MountCount UINT64,
|
||
|
mediaAccessDevice-DeviceID DisplayString,
|
||
|
mediaAccessDevice-PowerOnHours UINT64,
|
||
|
mediaAccessDevice-TotalPowerOnHours UINT64,
|
||
|
mediaAccessDevice-OperationalStatus INTEGER,
|
||
|
mediaAccessDevice-Realizes-StorageLocationIndex UINT32,
|
||
|
mediaAccessDevice-Realizes-softwareElementIndex UINT32
|
||
|
}
|
||
|
|
||
|
|
||
|
mediaAccessDeviceIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the MediaAccessDevice."
|
||
|
::= { mediaAccessDeviceEntry 1 }
|
||
|
|
||
|
|
||
|
mediaAccessDeviceObjectType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
wormDrive (1),
|
||
|
magnetoOpticalDrive (2),
|
||
|
tapeDrive (3),
|
||
|
dvdDrive (4),
|
||
|
cdromDrive (5) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"In the 2.7 CIM Schema a Type property is no longer
|
||
|
associated with MediaAccessDevice. However, it can be used
|
||
|
here to specify the type of drive that is present."
|
||
|
::= { mediaAccessDeviceEntry 2 }
|
||
|
|
||
|
|
||
|
mediaAccessDevice-Name OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"Deprecated"
|
||
|
::= { mediaAccessDeviceEntry 3 }
|
||
|
|
||
|
|
||
|
mediaAccessDevice-Status OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 10 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"A string indicating the current status of the object.
|
||
|
Various operational and non-operational statuses are defined.
|
||
|
This property is deprecated in lieu of OperationalStatus, which
|
||
|
includes the same semantics in its enumeration. This change
|
||
|
is made for three reasons:
|
||
|
1) Status is more correctly defined
|
||
|
as an array property. This overcomes the limitation of
|
||
|
describing status via a single value, when it is really a
|
||
|
multi-valued property (for example, an element may be OK AND
|
||
|
Stopped.
|
||
|
2) A MaxLen of 10 is too restrictive and leads to unclear
|
||
|
enumerated values. And,
|
||
|
3) The change to a uint16 data type was discussed when CIM V2.0
|
||
|
was defined. However, existing V1.0 implementations used the
|
||
|
string property and did not want to modify their code.
|
||
|
Therefore, Status was grandfathered into the Schema.
|
||
|
Use of the Deprecated qualifier allows the maintenance
|
||
|
of the existing property, but also permits an improved
|
||
|
definition using OperationalStatus."
|
||
|
|
||
|
::= { mediaAccessDeviceEntry 4 }
|
||
|
|
||
|
|
||
|
mediaAccessDevice-Availability OBJECT-TYPE
|
||
|
SYNTAX INTEGER { other (1),
|
||
|
unknown (2),
|
||
|
runningFullPower (3),
|
||
|
warning (4),
|
||
|
inTest (5),
|
||
|
notApplicable (6),
|
||
|
powerOff (7),
|
||
|
offLine (8),
|
||
|
offDuty (9),
|
||
|
degraded (10),
|
||
|
notInstalled (11),
|
||
|
installError (12),
|
||
|
powerSaveUnknown (13),
|
||
|
powerSaveLowPowerMode (14),
|
||
|
powerSaveStandby (15),
|
||
|
powerCycle (16),
|
||
|
powerSaveWarning (17),
|
||
|
paused (18),
|
||
|
notReady (19),
|
||
|
notConfigured (20),
|
||
|
quiesced (21) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Inherited from CIM_LogicalDevice
|
||
|
|
||
|
The primary availability and status of the Device.
|
||
|
(Additional status information can be specified using the
|
||
|
Additional Availability array property.) For example, the
|
||
|
Availability property indicates that the Device is running
|
||
|
and has full power (value=3), or is in a warning (4), test
|
||
|
(5), degraded (10) or power save state (values 13-15 and
|
||
|
17). Regarding the Power Save states, these are defined as
|
||
|
follows: Value 13 (Power Save - Unknown) indicates that
|
||
|
the Device is known to be in a power save mode, but its
|
||
|
exact status in this mode is unknown; 14 (Power Save -
|
||
|
Low Power Mode) indicates that the Device is in a power
|
||
|
save state but still functioning, and may exhibit degraded
|
||
|
performance; 15 (Power Save - Standby) describes that
|
||
|
the Device is not functioning but could be brought to full
|
||
|
power 'quickly'; and value 17 (Power Save - Warning)
|
||
|
indicates that the Device is in a warning state, though
|
||
|
also in a power save mode."
|
||
|
::= { mediaAccessDeviceEntry 5 }
|
||
|
|
||
|
|
||
|
mediaAccessDevice-NeedsCleaning OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Boolean indicating that the MediaAccessDevice needs
|
||
|
cleaning. Whether manual or automatic cleaning is possible
|
||
|
is indicated in the Capabilities array property. "
|
||
|
::= { mediaAccessDeviceEntry 6 }
|
||
|
|
||
|
|
||
|
mediaAccessDevice-MountCount OBJECT-TYPE
|
||
|
SYNTAX UINT64
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"For a MediaAccessDevice that supports removable
|
||
|
Media, the number of times that Media have been mounted for
|
||
|
data transfer or to clean the Device. For Devices accessing
|
||
|
nonremovable Media, such as hard disks, this property is
|
||
|
not applicable and should be set to 0."
|
||
|
::= { mediaAccessDeviceEntry 7 }
|
||
|
|
||
|
|
||
|
mediaAccessDevice-DeviceID OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An address or other identifying information to
|
||
|
uniquely name the LogicalDevice."
|
||
|
::= { mediaAccessDeviceEntry 8 }
|
||
|
|
||
|
|
||
|
mediaAccessDevice-PowerOnHours OBJECT-TYPE
|
||
|
SYNTAX UINT64
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of consecutive hours that this Device has
|
||
|
been powered, since its last power cycle."
|
||
|
::= { mediaAccessDeviceEntry 9 }
|
||
|
|
||
|
|
||
|
mediaAccessDevice-TotalPowerOnHours OBJECT-TYPE
|
||
|
SYNTAX UINT64
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The total number of hours that this Device has been powered."
|
||
|
::= { mediaAccessDeviceEntry 10 }
|
||
|
|
||
|
|
||
|
mediaAccessDevice-OperationalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { unknown (0),
|
||
|
other (1),
|
||
|
ok (2),
|
||
|
degraded (3),
|
||
|
stressed (4),
|
||
|
predictiveFailure (5),
|
||
|
error (6),
|
||
|
non-RecoverableError (7),
|
||
|
starting (8),
|
||
|
stopping (9),
|
||
|
stopped (10),
|
||
|
inService (11),
|
||
|
noContact (12),
|
||
|
lostCommunication (13),
|
||
|
aborted (14),
|
||
|
dormant (15),
|
||
|
supportingEntityInError (16),
|
||
|
completed (17),
|
||
|
powerMode (18),
|
||
|
dMTFReserved (19),
|
||
|
vendorReserved (32768) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Indicates the current status(es) of the element.
|
||
|
Various health and operational statuses are defined. Many of
|
||
|
the enumeration's values are self- explanatory. However, a few
|
||
|
are not and are described in more detail. \n
|
||
|
'Stressed' indicates that the element is functioning, but
|
||
|
needs attention. Examples of 'Stressed' states are
|
||
|
overload, overheated, etc. \n
|
||
|
'Predictive Failure' indicates that an element is
|
||
|
functioning nominally but predicting a failure in the near
|
||
|
future. \n
|
||
|
'In Service' describes an element being configured,
|
||
|
maintained, cleaned, or otherwise administered. \n
|
||
|
'No Contact' indicates that the monitoring system has
|
||
|
knowledge of this element, but has never been able to
|
||
|
establish communications with it. \n
|
||
|
'Lost Communication' indicates that the ManagedSystem
|
||
|
Element is known to exist and has been contacted
|
||
|
successfully in the past, but is currently unreachable. \n
|
||
|
'Stopped' and 'Aborted' are similar, although the
|
||
|
former implies a clean and orderly stop, while the latter
|
||
|
implies an abrupt stop where the element's state and
|
||
|
configuration may need to be updated. \n
|
||
|
'Dormant' indicates that the element is inactive or
|
||
|
quiesced. \n
|
||
|
'Supporting Entity in Error' describes that this element
|
||
|
may be 'OK' but that another element, on which it is
|
||
|
dependent, is in error. An example is a network service or
|
||
|
endpoint that cannot function due to lower layer networking
|
||
|
problems. \n
|
||
|
'Completed' indicates the element has completed its
|
||
|
operation. This value should be combined with either OK,
|
||
|
Error, or Degraded so that a client can till if the
|
||
|
complete operation passed (Completed with OK), and failure
|
||
|
(Completed with Error). Completed with Degraded would imply
|
||
|
the operation finished, but did not complete OK or report
|
||
|
an error. \n
|
||
|
'Power Mode' indicates the element has additional power
|
||
|
model information contained in the Associated
|
||
|
PowerManagementService association. \n
|
||
|
OperationalStatus replaces the Status property on
|
||
|
ManagedSystemElement to provide a consistent approach to
|
||
|
enumerations, to address implementation needs for an array
|
||
|
property, and to provide a migration path from today's
|
||
|
environment to the future. This change was not made earlier
|
||
|
since it required the DEPRECATED qualifier. Due to the
|
||
|
widespread use of the existing Status property in
|
||
|
management applications, it is strongly RECOMMENDED that
|
||
|
providers/instrumentation provide BOTH the Status and
|
||
|
OperationalStatus properties. Further, the first value of
|
||
|
OperationalStatus SHOULD contain the primary status for the
|
||
|
element. When instrumented, Status (since it is
|
||
|
single-valued) SHOULD also provide the primary status of
|
||
|
the element."
|
||
|
::= { mediaAccessDeviceEntry 11 }
|
||
|
|
||
|
|
||
|
mediaAccessDevice-Realizes-StorageLocationIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the
|
||
|
storageMediaLocationIndex that this MediaAccessDevice is
|
||
|
associated with.
|
||
|
If no association exists an index of 0 may be returned."
|
||
|
::= { mediaAccessDeviceEntry 12 }
|
||
|
|
||
|
|
||
|
mediaAccessDevice-Realizes-softwareElementIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the softwareElementIndex
|
||
|
that this MediaAccessDevice is associated with.
|
||
|
If no association exists an index of 0 may be returned."
|
||
|
::= { mediaAccessDeviceEntry 13 }
|
||
|
|
||
|
|
||
|
|
||
|
physicalPackageGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 8 }
|
||
|
|
||
|
numberOfPhysicalPackages OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the number of PhysicalPackages
|
||
|
that are present."
|
||
|
::= { physicalPackageGroup 1 }
|
||
|
|
||
|
physicalPackageTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PhysicalPackage-Table
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The PhysicalPackage class represents PhysicalElements
|
||
|
that contain or host other components. Examples are a Rack
|
||
|
enclosure or an adapter Card. (also a tape magazine inside
|
||
|
an auto-loader)"
|
||
|
::= { physicalPackageGroup 2 }
|
||
|
|
||
|
physicalPackageEntry OBJECT-TYPE
|
||
|
SYNTAX PhysicalPackage-Table
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Each entry in the table contains information about a
|
||
|
PhysicalPackage that is present in the library."
|
||
|
INDEX { physicalPackageIndex }
|
||
|
::= { physicalPackageTable 1 }
|
||
|
|
||
|
PhysicalPackage-Table ::= SEQUENCE {
|
||
|
physicalPackageIndex UINT32,
|
||
|
physicalPackage-Manufacturer DisplayString,
|
||
|
physicalPackage-Model DisplayString,
|
||
|
physicalPackage-SerialNumber DisplayString,
|
||
|
physicalPackage-Realizes-MediaAccessDeviceIndex Integer32,
|
||
|
physicalPackage-Tag DisplayString
|
||
|
}
|
||
|
|
||
|
|
||
|
physicalPackageIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the PhysicalPackage."
|
||
|
::= { physicalPackageEntry 1 }
|
||
|
|
||
|
|
||
|
physicalPackage-Manufacturer OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The name of the organization responsible for
|
||
|
producing the PhysicalElement.
|
||
|
This may be the entity from whom the Element is purchased,
|
||
|
but this is not necessarily true. The latter information is
|
||
|
contained in the Vendor property of CIM_Product."
|
||
|
::= { physicalPackageEntry 2 }
|
||
|
|
||
|
|
||
|
physicalPackage-Model OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The name by which the PhysicalElement is generally known."
|
||
|
::= { physicalPackageEntry 3 }
|
||
|
|
||
|
|
||
|
physicalPackage-SerialNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A manufacturer-allocated number used to identify the
|
||
|
Physical Element."
|
||
|
::= { physicalPackageEntry 4 }
|
||
|
|
||
|
|
||
|
physicalPackage-Realizes-MediaAccessDeviceIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The index value of the the MediaAccess device that
|
||
|
is associated with this physical package.'"
|
||
|
::= { physicalPackageEntry 5 }
|
||
|
|
||
|
|
||
|
physicalPackage-Tag OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An arbitrary string that uniquely identifies the
|
||
|
Physical Element and serves as the Element's key. The Tag
|
||
|
property can contain information such as asset tag or serial
|
||
|
number data. The key for PhysicalElement is placed very high in
|
||
|
the object hierarchy in order to independently identify the
|
||
|
hardware/entity, regardless of physical placement in or on
|
||
|
Cabinets, Adapters, etc. For example, a hotswappable or
|
||
|
removeable component may be taken from its containing
|
||
|
(scoping) Package and be temporarily unused. The object
|
||
|
still continues to exist - and may even be inserted into a
|
||
|
different scoping container. Therefore, the key for
|
||
|
Physical Element is an arbitrary string and is defined
|
||
|
independently of any placement or location-oriented
|
||
|
hierarchy."
|
||
|
::= { physicalPackageEntry 6 }
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
softwareElementGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 9 }
|
||
|
|
||
|
numberOfSoftwareElements OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the number of SoftwareElements
|
||
|
that are present."
|
||
|
::= { softwareElementGroup 1 }
|
||
|
|
||
|
softwareElementTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SoftwareElement-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The CIM_SoftwareElement class is used to decompose a
|
||
|
CIM_SoftwareFeature object into a set of individually manageable
|
||
|
or deployable parts for a particular platform. A software
|
||
|
element's platform is uniquely identified
|
||
|
by its underlying hardware architecture and operating system
|
||
|
(for example Sun Solaris on Sun Sparc or Windows NT on Intel).
|
||
|
As such, to understand the details of how the functionality of
|
||
|
a particular software feature is provided on a particular
|
||
|
platform, the CIM_SoftwareElement objects referenced
|
||
|
by CIM_SoftwareFeatureSoftwareElement associations are
|
||
|
organized in disjoint sets based on the TargetOperatingSystem
|
||
|
property. A CIM_SoftwareElement object captures the management
|
||
|
details of a part or component in one of four
|
||
|
states characterized by the SoftwareElementState property. "
|
||
|
::= { softwareElementGroup 2 }
|
||
|
|
||
|
softwareElementEntry OBJECT-TYPE
|
||
|
SYNTAX SoftwareElement-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Each entry in the table contains information about a
|
||
|
SoftwareElement that is present in the library."
|
||
|
INDEX { softwareElementIndex }
|
||
|
::= { softwareElementTable 1 }
|
||
|
|
||
|
SoftwareElement-Table-Info ::= SEQUENCE {
|
||
|
softwareElementIndex UINT32,
|
||
|
softwareElement-Name DisplayString,
|
||
|
softwareElement-Version DisplayString,
|
||
|
softwareElement-SoftwareElementID DisplayString,
|
||
|
softwareElement-Manufacturer DisplayString,
|
||
|
softwareElement-BuildNumber DisplayString,
|
||
|
softwareElement-SerialNumber DisplayString,
|
||
|
softwareElement-CodeSet DisplayString,
|
||
|
softwareElement-IdentificationCode DisplayString,
|
||
|
softwareElement-LanguageEdition DisplayString,
|
||
|
softwareElement-InstanceID DisplayString
|
||
|
}
|
||
|
|
||
|
|
||
|
softwareElementIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the SoftwareElement."
|
||
|
::= { softwareElementEntry 1 }
|
||
|
|
||
|
|
||
|
softwareElement-Name OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"deprecated"
|
||
|
::= { softwareElementEntry 2 }
|
||
|
|
||
|
|
||
|
softwareElement-Version OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Version should be in the form .. or . "
|
||
|
::= { softwareElementEntry 3 }
|
||
|
|
||
|
|
||
|
softwareElement-SoftwareElementID OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"SoftwareIdentity represents software, viewed as an
|
||
|
asset and/or individually identifiable entity (similar to
|
||
|
Physical Element). It does NOT indicate whether the software
|
||
|
is installed, executing, etc. (The latter is the role of the
|
||
|
SoftwareFeature/ SoftwareElement classes and the Application
|
||
|
Model.) Since software may be acquired, SoftwareIdentity can
|
||
|
be associated with a Product using the
|
||
|
ProductSoftwareComponent relationship.
|
||
|
Note that the Application Model manages the deployment and
|
||
|
installation of software via the classes, SoftwareFeatures and
|
||
|
SoftwareElements. The deployment/installation concepts are
|
||
|
related to the asset/identity one. In fact, a SoftwareIdentity
|
||
|
may correspond to a Product, or to one or more
|
||
|
SoftwareFeatures or SoftwareElements - depending on the
|
||
|
granularity of these classes and the deployment model. The
|
||
|
correspondence of Software Identity to Product,
|
||
|
SoftwareFeature or SoftwareElement is indicated using the
|
||
|
ConcreteIdentity association. Note that there may not be
|
||
|
sufficient detail or instrumentation to instantiate
|
||
|
ConcreteIdentity. And, if the association is instantiated,
|
||
|
some duplication of information may result. For example, the
|
||
|
Vendor described in the instances of Product and
|
||
|
SoftwareIdentity MAY be the same. However, this is not
|
||
|
necessarily true, and it is why vendor and similar information
|
||
|
are duplicated in this class.
|
||
|
Note that ConcreteIdentity can also be used to describe the
|
||
|
relationship of the software to any LogicalFiles that result
|
||
|
from installing it. As above, there may not be sufficient
|
||
|
detail or instrumentation to instantiate this association."
|
||
|
::= { softwareElementEntry 4 }
|
||
|
|
||
|
|
||
|
softwareElement-Manufacturer OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Manufacturer of this software element"
|
||
|
::= { softwareElementEntry 5 }
|
||
|
|
||
|
|
||
|
softwareElement-BuildNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The internal identifier for this compilation of this
|
||
|
software element."
|
||
|
::= { softwareElementEntry 6 }
|
||
|
|
||
|
|
||
|
softwareElement-SerialNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The assigned serial number of this software element."
|
||
|
::= { softwareElementEntry 7 }
|
||
|
|
||
|
|
||
|
softwareElement-CodeSet OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The code set used by this software element. "
|
||
|
::= { softwareElementEntry 8 }
|
||
|
|
||
|
|
||
|
softwareElement-IdentificationCode OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The value of this property is the manufacturer's
|
||
|
identifier for this software element. Often this will be a
|
||
|
stock keeping unit (SKU) or a part number."
|
||
|
::= { softwareElementEntry 9 }
|
||
|
|
||
|
|
||
|
softwareElement-LanguageEdition OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The value of this property identifies the language
|
||
|
edition of this software element. The language codes defined in
|
||
|
ISO 639 should be used. Where the software element represents
|
||
|
multi-lingual or international version of a
|
||
|
product, the string multilingual should be used."
|
||
|
::= { softwareElementEntry 10 }
|
||
|
|
||
|
|
||
|
softwareElement-InstanceID OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Within the scope of the instantiating Namespace,
|
||
|
InstanceID opaquely and uniquely identifies an instance of this
|
||
|
class. In order to ensure uniqueness within the NameSpace, the
|
||
|
value of InstanceID SHOULD be constructed using the
|
||
|
following 'preferred' algorithm:
|
||
|
<OrgID>:<LocalID>
|
||
|
Where <OrgID> and <LocalID> are separated by a colon ':',
|
||
|
and where <OrgID> MUST include a copyrighted, trademarked
|
||
|
or otherwise unique name that is owned by the business
|
||
|
entity creating/defining the InstanceID, or is a registered
|
||
|
ID that is assigned to the business entity by a recognized
|
||
|
global authority (This is similar to the <Schema
|
||
|
Name>_<Class Name> structure of Schema class names.) In
|
||
|
addition, to ensure uniqueness <OrgID> MUST NOT contain a
|
||
|
colon (':'). When using this algorithm, the first colon to
|
||
|
appear in InstanceID MUST appear between <OrgID> and
|
||
|
<LocalID>.
|
||
|
<LocalID> is chosen by the business entity and SHOULD not
|
||
|
be re-used to identify different underlying (real-world)
|
||
|
elements. If the above 'preferred' algorithm is not used,
|
||
|
the defining entity MUST assure that the resultant
|
||
|
InstanceID is not re-used across any InstanceIDs produced
|
||
|
by this or other providers for this instance's NameSpace.
|
||
|
For DMTF defined instances, the 'preferred' algorithm MUST
|
||
|
be used with the <OrgID> set to 'CIM'."
|
||
|
::= { softwareElementEntry 11 }
|
||
|
|
||
|
|
||
|
|
||
|
computerSystemGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 10 }
|
||
|
|
||
|
computerSystem-ElementName OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A user-friendly name for the object. This property
|
||
|
allows each instance to define a user-friendly name IN ADDITION
|
||
|
TO its key properties/identity data, and description
|
||
|
information. \n
|
||
|
Note that ManagedSystemElement's Name property is also
|
||
|
defined as a user-friendly name. But, it is often
|
||
|
subclassed to be a Key. It is not reasonable that the same
|
||
|
property can convey both identity and a user friendly name,
|
||
|
without inconsistencies. Where Name exists and is not a Key
|
||
|
(such as for instances of LogicalDevice), the same
|
||
|
information MAY be present in both the Name and ElementName
|
||
|
properties."
|
||
|
::= { computerSystemGroup 1 }
|
||
|
|
||
|
computerSystem-OperationalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { unknown (0),
|
||
|
other (1),
|
||
|
ok (2),
|
||
|
degraded (3),
|
||
|
stressed (4),
|
||
|
predictiveFailure (5),
|
||
|
error (6),
|
||
|
non-RecoverableError (7),
|
||
|
starting (8),
|
||
|
stopping (9),
|
||
|
stopped (10),
|
||
|
inService (11),
|
||
|
noContact (12),
|
||
|
lostCommunication (13),
|
||
|
aborted (14),
|
||
|
dormant (15),
|
||
|
supportingEntityInError (16),
|
||
|
completed (17),
|
||
|
powerMode (18),
|
||
|
dMTFReserved (19),
|
||
|
vendorReserved (32768) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Indicates the current status(es) of the element.
|
||
|
Various health and operational statuses are defined. Many of
|
||
|
the enumeration's values are self- explanatory. However, a few
|
||
|
are not and are described in more detail. \n
|
||
|
'Stressed' indicates that the element is functioning, but
|
||
|
needs attention. Examples of 'Stressed' states are
|
||
|
overload, overheated, etc. \n
|
||
|
'Predictive Failure' indicates that an element is
|
||
|
functioning nominally but predicting a failure in the near
|
||
|
future. \n
|
||
|
'In Service' describes an element being configured,
|
||
|
maintained, cleaned, or otherwise administered. \n
|
||
|
'No Contact' indicates that the monitoring system has
|
||
|
knowledge of this element, but has never been able to
|
||
|
establish communications with it. \n
|
||
|
'Lost Communication' indicates that the ManagedSystem
|
||
|
Element is known to exist and has been contacted
|
||
|
successfully in the past, but is currently unreachable. \n
|
||
|
'Stopped' and 'Aborted' are similar, although the
|
||
|
former implies a clean and orderly stop, while the latter
|
||
|
implies an abrupt stop where the element's state and
|
||
|
configuration may need to be updated. \n
|
||
|
'Dormant' indicates that the element is inactive or
|
||
|
quiesced. \n
|
||
|
'Supporting Entity in Error' describes that this element
|
||
|
may be 'OK' but that another element, on which it is
|
||
|
dependent, is in error. An example is a network service or
|
||
|
endpoint that cannot function due to lower layer networking
|
||
|
problems. \n
|
||
|
'Completed' indicates the element has completed its
|
||
|
operation. This value should be combined with either OK,
|
||
|
Error, or Degraded so that a client can till if the
|
||
|
complete operation passed (Completed with OK), and failure
|
||
|
(Completed with Error). Completed with Degraded would imply
|
||
|
the operation finished, but did not complete OK or report
|
||
|
an error. \n
|
||
|
'Power Mode' indicates the element has additional power
|
||
|
model information contained in the Associated
|
||
|
PowerManagementService association. \n
|
||
|
OperationalStatus replaces the Status property on
|
||
|
ManagedSystemElement to provide a consistent approach to
|
||
|
enumerations, to address implementation needs for an array
|
||
|
property, and to provide a migration path from today's
|
||
|
environment to the future. This change was not made earlier
|
||
|
since it required the DEPRECATED qualifier. Due to the
|
||
|
widespread use of the existing Status property in
|
||
|
management applications, it is strongly RECOMMENDED that
|
||
|
providers/instrumentation provide BOTH the Status and
|
||
|
OperationalStatus properties. Further, the first value of
|
||
|
OperationalStatus SHOULD contain the primary status for the
|
||
|
element. When instrumented, Status (since it is
|
||
|
single-valued) SHOULD also provide the primary status of
|
||
|
the element."
|
||
|
::= { computerSystemGroup 2 }
|
||
|
|
||
|
computerSystem-Name OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION "The Name property defines the label by which the
|
||
|
object is known. When subclassed, the Name property can be
|
||
|
overridden to be a Key property."
|
||
|
::= { computerSystemGroup 3 }
|
||
|
|
||
|
computerSystem-NameFormat OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The ComputerSystem object and its derivatives are
|
||
|
Top Level Objects of CIM. They provide the scope for numerous
|
||
|
components. Having unique System keys is required. The
|
||
|
NameFormat property identifies how the ComputerSystem Name
|
||
|
is generated. The NameFormat ValueMap qualifier defines the
|
||
|
various mechanisms for assigning the name. Note that
|
||
|
another name can be assigned and used for the
|
||
|
ComputerSystem that better suit a business, using the
|
||
|
inherited ElementName property. Possible values include
|
||
|
'Other', 'IP', 'Dial', 'HID', 'NWA', 'HWA', 'X25',
|
||
|
'ISDN', 'IPX', 'DCC', 'ICD', 'E.164', 'SNA', 'OID/OSI',
|
||
|
'WWN', 'NAA'"
|
||
|
::= { computerSystemGroup 4 }
|
||
|
|
||
|
computerSystem-Dedicated OBJECT-TYPE
|
||
|
SYNTAX INTEGER { notDedicated (0),
|
||
|
unknown (1),
|
||
|
other (2),
|
||
|
storage (3),
|
||
|
router (4),
|
||
|
switch (5),
|
||
|
layer3switch (6),
|
||
|
centralOfficeSwitch (7),
|
||
|
hub (8),
|
||
|
accessServer (9),
|
||
|
firewall (10),
|
||
|
print (11),
|
||
|
io (12),
|
||
|
webCaching (13),
|
||
|
management (14),
|
||
|
blockServer (15),
|
||
|
fileServer (16),
|
||
|
mobileUserDevice (17),
|
||
|
repeater (18),
|
||
|
bridgeExtender (19),
|
||
|
gateway (20) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Enumeration indicating whether the ComputerSystem is
|
||
|
a special-purpose System (ie, dedicated to a particular use),
|
||
|
versus being 'general purpose'. For example, one could
|
||
|
specify that the System is dedicated to 'Print'
|
||
|
(value=11) or acts as a 'Hub' (value=8). \n
|
||
|
A clarification is needed with respect to the value 17
|
||
|
('Mobile User Device'). An example of a dedicated user
|
||
|
device is a mobile phone or a barcode scanner in a store
|
||
|
that communicates via radio frequency. These systems are
|
||
|
quite limited in functionality and programmability, and are
|
||
|
not considered 'general purpose' computing platforms.
|
||
|
Alternately, an example of a mobile system that is 'general
|
||
|
purpose' (i.e., is NOT dedicated) is a hand-held computer.
|
||
|
Although limited in its programmability, new software can
|
||
|
be downloaded and its functionality expanded by the user."
|
||
|
::= { computerSystemGroup 5 }
|
||
|
|
||
|
computerSystem-PrimaryOwnerContact OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A string that provides information on how the primary
|
||
|
system owner can be reached (e.g. phone number, email
|
||
|
address, ...)"
|
||
|
::= { computerSystemGroup 6 }
|
||
|
|
||
|
computerSystem-PrimaryOwnerName OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The name of the primary system owner. The system
|
||
|
owner is the primary user of the system."
|
||
|
::= { computerSystemGroup 7 }
|
||
|
|
||
|
computerSystem-Description OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Description property provides a textual
|
||
|
description of the object."
|
||
|
::= { computerSystemGroup 8 }
|
||
|
|
||
|
computerSystem-Caption OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Caption property is a short textual description
|
||
|
(one- line string) of the object."
|
||
|
::= { computerSystemGroup 9 }
|
||
|
|
||
|
computerSystem-Realizes-softwareElementIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the softwareElementIndex
|
||
|
that this computerSystem is associated with.
|
||
|
If no association exists an index of 0 may be returned."
|
||
|
::= { computerSystemGroup 10 }
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
changerDeviceGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 11 }
|
||
|
|
||
|
numberOfChangerDevices OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the number of ChangerDevices
|
||
|
that are present."
|
||
|
::= { changerDeviceGroup 1 }
|
||
|
|
||
|
changerDeviceTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF ChangerDevice-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The changerDevice class represents changerDevices in the library"
|
||
|
::= { changerDeviceGroup 2 }
|
||
|
|
||
|
changerDeviceEntry OBJECT-TYPE
|
||
|
SYNTAX ChangerDevice-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Each entry in the table contains information about a
|
||
|
changerDevice that is present in the library."
|
||
|
INDEX { changerDeviceIndex }
|
||
|
::= { changerDeviceTable 1 }
|
||
|
|
||
|
ChangerDevice-Table-Info ::= SEQUENCE {
|
||
|
changerDeviceIndex UINT32,
|
||
|
changerDevice-DeviceID DisplayString,
|
||
|
changerDevice-MediaFlipSupported INTEGER,
|
||
|
changerDevice-ElementName DisplayString,
|
||
|
changerDevice-Caption DisplayString,
|
||
|
changerDevice-Description DisplayString,
|
||
|
changerDevice-Availability INTEGER,
|
||
|
changerDevice-OperationalStatus INTEGER,
|
||
|
changerDevice-Realizes-StorageLocationIndex UINT32
|
||
|
}
|
||
|
|
||
|
|
||
|
changerDeviceIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the changerDevice."
|
||
|
::= { changerDeviceEntry 1 }
|
||
|
|
||
|
|
||
|
changerDevice-DeviceID OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An address or other identifying information to
|
||
|
uniquely name the LogicalDevice."
|
||
|
::= { changerDeviceEntry 2 }
|
||
|
|
||
|
|
||
|
changerDevice-MediaFlipSupported OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Boolean set to TRUE if the Changer supports media
|
||
|
flipping. Media needs to be flipped when multi-sided
|
||
|
PhysicalMedia are placed into a MediaAccessDevice that does
|
||
|
NOT support dual sided access."
|
||
|
::= { changerDeviceEntry 3 }
|
||
|
|
||
|
|
||
|
changerDevice-ElementName OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A user-friendly name for the object. This property
|
||
|
allows each instance to define a user-friendly name IN ADDITION
|
||
|
TO its key properties/identity data, and description
|
||
|
information.
|
||
|
Note that ManagedSystemElement's Name property is also
|
||
|
defined as a user-friendly name. But, it is often
|
||
|
subclassed to be a Key. It is not reasonable that the same
|
||
|
property can convey both identity and a user friendly name,
|
||
|
without inconsistencies. Where Name exists and is not a Key
|
||
|
(such as for instances of LogicalDevice), the same
|
||
|
information MAY be present in both the Name and ElementName
|
||
|
properties."
|
||
|
::= { changerDeviceEntry 4 }
|
||
|
|
||
|
|
||
|
changerDevice-Caption OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Caption property is a short textual description
|
||
|
(one- line string) of the object."
|
||
|
::= { changerDeviceEntry 5 }
|
||
|
|
||
|
|
||
|
changerDevice-Description OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Description property provides a textual
|
||
|
description of the object."
|
||
|
::= { changerDeviceEntry 6 }
|
||
|
|
||
|
|
||
|
changerDevice-Availability OBJECT-TYPE
|
||
|
SYNTAX INTEGER { other (1),
|
||
|
unknown (2),
|
||
|
runningFullPower (3),
|
||
|
warning (4),
|
||
|
inTest (5),
|
||
|
notApplicable (6),
|
||
|
powerOff (7),
|
||
|
offLine (8),
|
||
|
offDuty (9),
|
||
|
degraded (10),
|
||
|
notInstalled (11),
|
||
|
installError (12),
|
||
|
powerSaveUnknown (13),
|
||
|
powerSaveLowPowerMode (14),
|
||
|
powerSaveStandby (15),
|
||
|
powerCycle (16),
|
||
|
powerSaveWarning (17),
|
||
|
paused (18),
|
||
|
notReady (19),
|
||
|
notConfigured (20),
|
||
|
quiesced (21) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The primary availability and status of the Device.
|
||
|
(Additional status information can be specified using the
|
||
|
Additional Availability array property.) For example, the
|
||
|
Availability property indicates that the Device is running
|
||
|
and has full power (value=3), or is in a warning (4), test
|
||
|
(5), degraded (10) or power save state (values 13-15 and
|
||
|
17). Regarding the Power Save states, these are defined as
|
||
|
follows Value 13 (\'Power Save - Unknown\') indicates that
|
||
|
the Device is known to be in a power save mode, but its
|
||
|
exact status in this mode is unknown; 14 (\'Power Save -
|
||
|
Low Power Mode\') indicates that the Device is in a power
|
||
|
save state but still functioning, and may exhibit degraded
|
||
|
performance 15 (\'Power Save - Standby\') describes that
|
||
|
the Device is not functioning but could be brought to full
|
||
|
power 'quickly'; and value 17 (\'Power Save - Warning\')
|
||
|
indicates that the Device is in a warning state, though
|
||
|
also in a power save mode."
|
||
|
::= { changerDeviceEntry 8 }
|
||
|
|
||
|
|
||
|
changerDevice-OperationalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { unknown (0),
|
||
|
other (1),
|
||
|
ok (2),
|
||
|
degraded (3),
|
||
|
stressed (4),
|
||
|
predictiveFailure (5),
|
||
|
error (6),
|
||
|
non-RecoverableError (7),
|
||
|
starting (8),
|
||
|
stopping (9),
|
||
|
stopped (10),
|
||
|
inService (11),
|
||
|
noContact (12),
|
||
|
lostCommunication (13),
|
||
|
aborted (14),
|
||
|
dormant (15),
|
||
|
supportingEntityInError (16),
|
||
|
completed (17),
|
||
|
powerMode (18),
|
||
|
dMTFReserved (19),
|
||
|
vendorReserved (32768) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Indicates the current status(es) of the element.
|
||
|
Various health and operational statuses are defined. Many of
|
||
|
the enumeration's values are self- explanatory. However, a few
|
||
|
are not and are described in more detail. \n
|
||
|
'Stressed' indicates that the element is functioning, but
|
||
|
needs attention. Examples of 'Stressed' states are
|
||
|
overload, overheated, etc. \n
|
||
|
'Predictive Failure' indicates that an element is
|
||
|
functioning nominally but predicting a failure in the near
|
||
|
future. \n
|
||
|
'In Service' describes an element being configured,
|
||
|
maintained, cleaned, or otherwise administered. \n
|
||
|
'No Contact' indicates that the monitoring system has
|
||
|
knowledge of this element, but has never been able to
|
||
|
establish communications with it. \n
|
||
|
'Lost Communication' indicates that the ManagedSystem
|
||
|
Element is known to exist and has been contacted
|
||
|
successfully in the past, but is currently unreachable. \n
|
||
|
'Stopped' and 'Aborted' are similar, although the
|
||
|
former implies a clean and orderly stop, while the latter
|
||
|
implies an abrupt stop where the element's state and
|
||
|
configuration may need to be updated. \n
|
||
|
'Dormant' indicates that the element is inactive or
|
||
|
quiesced. \n
|
||
|
'Supporting Entity in Error' describes that this element
|
||
|
may be 'OK' but that another element, on which it is
|
||
|
dependent, is in error. An example is a network service or
|
||
|
endpoint that cannot function due to lower layer networking
|
||
|
problems. \n
|
||
|
'Completed' indicates the element has completed its
|
||
|
operation. This value should be combined with either OK,
|
||
|
Error, or Degraded so that a client can till if the
|
||
|
complete operation passed (Completed with OK), and failure
|
||
|
(Completed with Error). Completed with Degraded would imply
|
||
|
the operation finished, but did not complete OK or report
|
||
|
an error. \n
|
||
|
'Power Mode' indicates the element has additional power
|
||
|
model information contained in the Associated
|
||
|
PowerManagementService association. \n
|
||
|
OperationalStatus replaces the Status property on
|
||
|
ManagedSystemElement to provide a consistent approach to
|
||
|
enumerations, to address implementation needs for an array
|
||
|
property, and to provide a migration path from today's
|
||
|
environment to the future. This change was not made earlier
|
||
|
since it required the DEPRECATED qualifier. Due to the
|
||
|
widespread use of the existing Status property in
|
||
|
management applications, it is strongly RECOMMENDED that
|
||
|
providers/instrumentation provide BOTH the Status and
|
||
|
OperationalStatus properties. Further, the first value of
|
||
|
OperationalStatus SHOULD contain the primary status for the
|
||
|
element. When instrumented, Status (since it is
|
||
|
single-valued) SHOULD also provide the primary status of
|
||
|
the element."
|
||
|
::= { changerDeviceEntry 9 }
|
||
|
|
||
|
|
||
|
changerDevice-Realizes-StorageLocationIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the storageMediaLocationIndex
|
||
|
that this changerDevice is associated with.
|
||
|
If no association exists an index of 0 may be returned."
|
||
|
::= { changerDeviceEntry 10 }
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
scsiProtocolControllerGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 12 }
|
||
|
|
||
|
numberOfSCSIProtocolControllers OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the number of
|
||
|
SCSIProtocolControllers that are present."
|
||
|
::= { scsiProtocolControllerGroup 1 }
|
||
|
|
||
|
scsiProtocolControllerTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF ScsiProtocolController-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The scsiProtocolController class represents
|
||
|
SCSIProtocolControllers in the library"
|
||
|
::= { scsiProtocolControllerGroup 2 }
|
||
|
|
||
|
scsiProtocolControllerEntry OBJECT-TYPE
|
||
|
SYNTAX ScsiProtocolController-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Each entry in the table contains information about a
|
||
|
SCSIProtocolController that is present in the library."
|
||
|
INDEX { scsiProtocolControllerIndex }
|
||
|
::= { scsiProtocolControllerTable 1 }
|
||
|
|
||
|
ScsiProtocolController-Table-Info ::= SEQUENCE {
|
||
|
scsiProtocolControllerIndex UINT32,
|
||
|
scsiProtocolController-DeviceID DisplayString,
|
||
|
scsiProtocolController-ElementName DisplayString,
|
||
|
scsiProtocolController-OperationalStatus INTEGER,
|
||
|
scsiProtocolController-Description DisplayString,
|
||
|
scsiProtocolController-Availability INTEGER,
|
||
|
scsiProtocolController-Realizes-ChangerDeviceIndex UINT32,
|
||
|
scsiProtocolController-Realizes-MediaAccessDeviceIndex UINT32
|
||
|
}
|
||
|
|
||
|
|
||
|
scsiProtocolControllerIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the scsiProtocolController."
|
||
|
::= { scsiProtocolControllerEntry 1 }
|
||
|
|
||
|
|
||
|
scsiProtocolController-DeviceID OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An address or other identifying information to
|
||
|
uniquely name the LogicalDevice."
|
||
|
::= { scsiProtocolControllerEntry 2 }
|
||
|
|
||
|
|
||
|
scsiProtocolController-ElementName OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A user-friendly name for the object. This property
|
||
|
allows each instance to define a user-friendly name IN ADDITION
|
||
|
TO its key properties/identity data, and description
|
||
|
information.
|
||
|
Note that ManagedSystemElement's Name property is also
|
||
|
defined as a user-friendly name. But, it is often
|
||
|
subclassed to be a Key. It is not reasonable that the same
|
||
|
property can convey both identity and a user friendly name,
|
||
|
without inconsistencies. Where Name exists and is not a Key
|
||
|
(such as for instances of LogicalDevice), the same
|
||
|
information MAY be present in both the Name and ElementName
|
||
|
properties."
|
||
|
::= { scsiProtocolControllerEntry 3 }
|
||
|
|
||
|
|
||
|
scsiProtocolController-OperationalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { unknown (0),
|
||
|
other (1),
|
||
|
ok (2),
|
||
|
degraded (3),
|
||
|
stressed (4),
|
||
|
predictiveFailure (5),
|
||
|
error (6),
|
||
|
non-RecoverableError (7),
|
||
|
starting (8),
|
||
|
stopping (9),
|
||
|
stopped (10),
|
||
|
inService (11),
|
||
|
noContact (12),
|
||
|
lostCommunication (13),
|
||
|
aborted (14),
|
||
|
dormant (15),
|
||
|
supportingEntityInError (16),
|
||
|
completed (17),
|
||
|
powerMode (18),
|
||
|
dMTFReserved (19),
|
||
|
vendorReserved (32768) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Indicates the current status(es) of the element.
|
||
|
Various health and operational statuses are defined. Many of
|
||
|
the enumeration's values are self- explanatory. However, a few
|
||
|
are not and are described in more detail. \n
|
||
|
'Stressed' indicates that the element is functioning, but
|
||
|
needs attention. Examples of 'Stressed' states are
|
||
|
overload, overheated, etc. \n
|
||
|
'Predictive Failure' indicates that an element is
|
||
|
functioning nominally but predicting a failure in the near
|
||
|
future. \n
|
||
|
'In Service' describes an element being configured,
|
||
|
maintained, cleaned, or otherwise administered. \n
|
||
|
'No Contact' indicates that the monitoring system has
|
||
|
knowledge of this element, but has never been able to
|
||
|
establish communications with it. \n
|
||
|
'Lost Communication' indicates that the ManagedSystem
|
||
|
Element is known to exist and has been contacted
|
||
|
successfully in the past, but is currently unreachable. \n
|
||
|
'Stopped' and 'Aborted' are similar, although the
|
||
|
former implies a clean and orderly stop, while the latter
|
||
|
implies an abrupt stop where the element's state and
|
||
|
configuration may need to be updated. \n
|
||
|
'Dormant' indicates that the element is inactive or
|
||
|
quiesced. \n
|
||
|
'Supporting Entity in Error' describes that this element
|
||
|
may be 'OK' but that another element, on which it is
|
||
|
dependent, is in error. An example is a network service or
|
||
|
endpoint that cannot function due to lower layer networking
|
||
|
problems. \n
|
||
|
'Completed' indicates the element has completed its
|
||
|
operation. This value should be combined with either OK,
|
||
|
Error, or Degraded so that a client can till if the
|
||
|
complete operation passed (Completed with OK), and failure
|
||
|
(Completed with Error). Completed with Degraded would imply
|
||
|
the operation finished, but did not complete OK or report
|
||
|
an error. \n
|
||
|
'Power Mode' indicates the element has additional power
|
||
|
model information contained in the Associated
|
||
|
PowerManagementService association. \n
|
||
|
OperationalStatus replaces the Status property on
|
||
|
ManagedSystemElement to provide a consistent approach to
|
||
|
enumerations, to address implementation needs for an array
|
||
|
property, and to provide a migration path from today's
|
||
|
environment to the future. This change was not made earlier
|
||
|
since it required the DEPRECATED qualifier. Due to the
|
||
|
widespread use of the existing Status property in
|
||
|
management applications, it is strongly RECOMMENDED that
|
||
|
providers/instrumentation provide BOTH the Status and
|
||
|
OperationalStatus properties. Further, the first value of
|
||
|
OperationalStatus SHOULD contain the primary status for the
|
||
|
element. When instrumented, Status (since it is
|
||
|
single-valued) SHOULD also provide the primary status of
|
||
|
the element."
|
||
|
::= { scsiProtocolControllerEntry 4 }
|
||
|
|
||
|
|
||
|
scsiProtocolController-Description OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Description property provides a textual
|
||
|
description of the object."
|
||
|
::= { scsiProtocolControllerEntry 5 }
|
||
|
|
||
|
|
||
|
scsiProtocolController-Availability OBJECT-TYPE
|
||
|
SYNTAX INTEGER { other (1),
|
||
|
unknown (2),
|
||
|
runningFullPower (3),
|
||
|
warning (4),
|
||
|
inTest (5),
|
||
|
notApplicable (6),
|
||
|
powerOff (7),
|
||
|
offLine (8),
|
||
|
offDuty (9),
|
||
|
degraded (10),
|
||
|
notInstalled (11),
|
||
|
installError (12),
|
||
|
powerSaveUnknown (13),
|
||
|
powerSaveLowPowerMode (14),
|
||
|
powerSaveStandby (15),
|
||
|
powerCycle (16),
|
||
|
powerSaveWarning (17),
|
||
|
paused (18),
|
||
|
notReady (19),
|
||
|
notConfigured (20),
|
||
|
quiesced (21) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The primary availability and status of the Device.
|
||
|
(Additional status information can be specified using the
|
||
|
Additional Availability array property.) For example, the
|
||
|
Availability property indicates that the Device is running
|
||
|
and has full power (value=3), or is in a warning (4), test
|
||
|
(5), degraded (10) or power save state (values 13-15 and
|
||
|
17). Regarding the Power Save states, these are defined as
|
||
|
follows: Value 13 (\'Power Save - Unknown\') indicates that
|
||
|
the Device is known to be in a power save mode, but its
|
||
|
exact status in this mode is unknown; 14 (\'Power Save -
|
||
|
Low Power Mode\') indicates that the Device is in a power
|
||
|
save state but still functioning, and may exhibit degraded
|
||
|
performance; 15 (\'Power Save - Standby\') describes that
|
||
|
the Device is not functioning but could be brought to full
|
||
|
power 'quickly'; and value 17 (\'Power Save - Warning\')
|
||
|
indicates that the Device is in a warning state, though
|
||
|
also in a power save mode."
|
||
|
::= { scsiProtocolControllerEntry 6 }
|
||
|
|
||
|
|
||
|
scsiProtocolController-Realizes-ChangerDeviceIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the ChangerDeviceIndex
|
||
|
that this scsiProtocolController is associated with.
|
||
|
If no association exists an index of 0 may be returned."
|
||
|
::= { scsiProtocolControllerEntry 7 }
|
||
|
|
||
|
|
||
|
scsiProtocolController-Realizes-MediaAccessDeviceIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the
|
||
|
MediaAccessDeviceIndex that this scsiProtocolController is
|
||
|
associated with.
|
||
|
If no association exists an index of 0 may be returned."
|
||
|
::= { scsiProtocolControllerEntry 8 }
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
storageMediaLocationGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 13 }
|
||
|
|
||
|
numberOfStorageMediaLocations OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the number of StorageMediaLocations
|
||
|
that are present."
|
||
|
::= { storageMediaLocationGroup 1 }
|
||
|
|
||
|
numberOfPhysicalMedias OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the number of PhysicalMedia
|
||
|
that are present."
|
||
|
::= { storageMediaLocationGroup 2 }
|
||
|
|
||
|
storageMediaLocationTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF StorageMediaLocation-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"StorageMediaLocation represents a possible location for an
|
||
|
instance of PhysicalMedia. PhysicalMedia represents any type of
|
||
|
documentation or storage medium, such as tapes, CDROMs, etc.
|
||
|
This class is typically used to locate and manage Removable
|
||
|
Media (versus Media sealed with the MediaAccessDevice,
|
||
|
as a single Package, as is the case with hard disks). However,
|
||
|
'sealed' Media can also be modeled using this class, where the
|
||
|
Media would then be associated with the PhysicalPackage
|
||
|
using the PackagedComponent relationship. "
|
||
|
::= { storageMediaLocationGroup 3 }
|
||
|
|
||
|
storageMediaLocationEntry OBJECT-TYPE
|
||
|
SYNTAX StorageMediaLocation-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Each entry in the table contains information about a
|
||
|
StorageMediaLocation that is present in the library."
|
||
|
INDEX { storageMediaLocationIndex }
|
||
|
::= { storageMediaLocationTable 1 }
|
||
|
|
||
|
StorageMediaLocation-Table-Info ::= SEQUENCE {
|
||
|
storageMediaLocationIndex UINT32,
|
||
|
storageMediaLocation-Tag DisplayString,
|
||
|
storageMediaLocation-LocationType INTEGER,
|
||
|
storageMediaLocation-LocationCoordinates DisplayString,
|
||
|
storageMediaLocation-MediaTypesSupported INTEGER,
|
||
|
storageMediaLocation-MediaCapacity UINT32,
|
||
|
storageMediaLocation-Association-ChangerDeviceIndex UINT32,
|
||
|
storageMediaLocation-PhysicalMediaPresent INTEGER,
|
||
|
storageMediaLocation-PhysicalMedia-Removable INTEGER,
|
||
|
storageMediaLocation-PhysicalMedia-Replaceable INTEGER,
|
||
|
storageMediaLocation-PhysicalMedia-HotSwappable INTEGER,
|
||
|
storageMediaLocation-PhysicalMedia-Capacity UINT64,
|
||
|
storageMediaLocation-PhysicalMedia-MediaType INTEGER,
|
||
|
storageMediaLocation-PhysicalMedia-MediaDescription DisplayString,
|
||
|
storageMediaLocation-PhysicalMedia-CleanerMedia INTEGER,
|
||
|
storageMediaLocation-PhysicalMedia-DualSided INTEGER,
|
||
|
storageMediaLocation-PhysicalMedia-PhysicalLabel DisplayString,
|
||
|
storageMediaLocation-PhysicalMedia-Tag DisplayString
|
||
|
}
|
||
|
|
||
|
|
||
|
storageMediaLocationIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the StorageMediaLocation."
|
||
|
::= { storageMediaLocationEntry 1 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-Tag OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An arbitrary string that uniquely identifies the
|
||
|
Physical Element and serves as the Element's key. The Tag
|
||
|
property can contain information such as asset tag or serial
|
||
|
number data. The key for PhysicalElement is placed very high in
|
||
|
the object hierarchy in order to independently identify the
|
||
|
hardware/entity, regardless of physical placement in or on
|
||
|
Cabinets, Adapters, etc. For example, a hotswappable or
|
||
|
removeable component may be taken from its containing
|
||
|
(scoping) Package and be temporarily unused. The object
|
||
|
still continues to exist - and may even be inserted into a
|
||
|
different scoping container. Therefore, the key for
|
||
|
Physical Element is an arbitrary string and is defined
|
||
|
independently of any placement or location-oriented
|
||
|
hierarchy."
|
||
|
::= { storageMediaLocationEntry 2 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-LocationType OBJECT-TYPE
|
||
|
SYNTAX INTEGER { unknown (0),
|
||
|
other (1),
|
||
|
slot (2),
|
||
|
magazine (3),
|
||
|
mediaAccessDevice (4),
|
||
|
interLibraryPort (5),
|
||
|
limitedAccessPort (6),
|
||
|
door (7),
|
||
|
shelf (8),
|
||
|
vault (9) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The type of Location. For example, whether this is an
|
||
|
individual Media \'Slot\' (value=2), a MediaAccessDevice
|
||
|
(value=4) or a \'Magazine\' (value=3) is indicated in this
|
||
|
property."
|
||
|
::= { storageMediaLocationEntry 3 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-LocationCoordinates OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"LocationCoordinates represent the physical location
|
||
|
of the the FrameSlot instance. The property is defined as a
|
||
|
free-form string to allow the location information to be
|
||
|
described in vendor-unique terminology."
|
||
|
::= { storageMediaLocationEntry 4 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-MediaTypesSupported OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
other (1),
|
||
|
tape (2),
|
||
|
qic (3),
|
||
|
ait (4),
|
||
|
dtf (5),
|
||
|
dat (6),
|
||
|
eightmmTape (7),
|
||
|
nineteenmmTape (8),
|
||
|
dlt (9),
|
||
|
halfInchMO (10),
|
||
|
catridgeDisk (11),
|
||
|
jazDisk (12),
|
||
|
zipDisk (13),
|
||
|
syQuestDisk (14),
|
||
|
winchesterDisk (15),
|
||
|
cdRom (16),
|
||
|
cdRomXA (17),
|
||
|
cdI (18),
|
||
|
cdRecordable (19),
|
||
|
wORM (20),
|
||
|
magneto-Optical (21),
|
||
|
dvd (22),
|
||
|
dvdRWPlus (23),
|
||
|
dvdRAM (24),
|
||
|
dvdROM (25),
|
||
|
dvdVideo (26),
|
||
|
divx (27),
|
||
|
floppyDiskette (28),
|
||
|
hardDisk (29),
|
||
|
memoryCard (30),
|
||
|
hardCopy (31),
|
||
|
clikDisk (32),
|
||
|
cdRW (33),
|
||
|
cdDA (34),
|
||
|
cdPlus (35),
|
||
|
dvdRecordable (36),
|
||
|
dvdRW (37),
|
||
|
dvdAudio (38),
|
||
|
dvd5 (39),
|
||
|
dvd9 (40),
|
||
|
dvd10 (41),
|
||
|
dvd18 (42),
|
||
|
moRewriteable (43),
|
||
|
moWriteOnce (44),
|
||
|
moLIMDOW (45),
|
||
|
phaseChangeWO (46),
|
||
|
phaseChangeRewriteable (47),
|
||
|
phaseChangeDualRewriteable (48),
|
||
|
ablativeWriteOnce (49),
|
||
|
nearField (50),
|
||
|
miniQic (51),
|
||
|
travan (52),
|
||
|
eightmmMetal (53),
|
||
|
eightmmAdvanced (54),
|
||
|
nctp (55),
|
||
|
ltoUltrium (56),
|
||
|
ltoAccelis (57),
|
||
|
tape9Track (58),
|
||
|
tape18Track (59),
|
||
|
tape36Track (60),
|
||
|
magstar3590 (61),
|
||
|
magstarMP (62),
|
||
|
d2Tape (63),
|
||
|
dstSmall (64),
|
||
|
dstMedium (65),
|
||
|
dstLarge (66) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Certain StorageMediaLocations may only be able to
|
||
|
accept a limited set of PhysicalMedia MediaTypes. This property
|
||
|
defines an array containing the types of Media that are
|
||
|
acceptable for placement in the Location. Additional
|
||
|
information and description of the contained MediaTypes can
|
||
|
be provided using the TypesDescription array. Also, size
|
||
|
data (for example, DVD disc diameter) can be specified
|
||
|
using the MediaSizesSupported array. \n
|
||
|
\n
|
||
|
Values defined here correspond to those in the CIM_Physical
|
||
|
Media.MediaType property. This allows quick comparisons
|
||
|
using value equivalence calculations. It is understood that
|
||
|
there is no external physical difference between (for
|
||
|
example) DVD- Video and DVD-RAM. But, equivalent values in
|
||
|
both the Physical Media and StorageMediaLocation
|
||
|
enumerations allows for one for one comparisons with no
|
||
|
additional processing logic (i.e., the following is not
|
||
|
required ... if \'DVD-Video\' then value=\'DVD\')."
|
||
|
::= { storageMediaLocationEntry 5 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-MediaCapacity OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A StorageMediaLocation may hold more than one
|
||
|
PhysicalMedia - for example, a Magazine. This property
|
||
|
indicates the Physical Media capacity of the Location."
|
||
|
::= { storageMediaLocationEntry 6 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-Association-ChangerDeviceIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Experimental: The current index value for the
|
||
|
ChangerDeviceIndex that this storageMediaLocation is
|
||
|
associated with.
|
||
|
If no association exists an index of 0 may be returned.
|
||
|
This association allows a representation of the experimental
|
||
|
"
|
||
|
::= { storageMediaLocationEntry 7 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-PhysicalMediaPresent OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"'true' when Physical Media is present in this
|
||
|
storage location.
|
||
|
When this is 'false' -physicalMedia- entries are undefined"
|
||
|
::= { storageMediaLocationEntry 10 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-PhysicalMedia-Removable OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A PhysicalComponent is Removable if it is designed
|
||
|
to be taken in and out of the physical container in which it is
|
||
|
normally found, without impairing the function of the overall
|
||
|
packaging. A Component can still be Removable if power must be
|
||
|
'off' in order to perform the removal. If power can be
|
||
|
'on' and the Component removed, then the Element is both Removable
|
||
|
and HotSwappable. For example, an upgradeable Processor chip is
|
||
|
Removable."
|
||
|
::= { storageMediaLocationEntry 11 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-PhysicalMedia-Replaceable OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A PhysicalComponent is Replaceable if it is possible
|
||
|
to replace (FRU or upgrade) the Element with a physically
|
||
|
different one. For example, some ComputerSystems allow the main
|
||
|
Processor chip to be upgraded to one of a higher clock rating.
|
||
|
In this case, the Processor is said to be Replaceable.
|
||
|
All Removable Components are inherently Replaceable."
|
||
|
::= { storageMediaLocationEntry 12 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-PhysicalMedia-HotSwappable OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A PhysicalComponent is HotSwappable if it is
|
||
|
possible to replace the Element with a physically different but
|
||
|
equivalent one while the containing Package
|
||
|
has power applied to it (ie, is 'on'). For example, a fan
|
||
|
Component may be designed to be HotSwappable. All HotSwappable
|
||
|
Components are inherently Removable and Replaceable."
|
||
|
::= { storageMediaLocationEntry 13 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-PhysicalMedia-Capacity OBJECT-TYPE
|
||
|
SYNTAX UINT64
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of bytes that can be read from or written
|
||
|
to a Media. This property is not applicable to 'Hard Copy'
|
||
|
(documentation) or cleaner Media.
|
||
|
Data compression should not be assumed, as it would increase
|
||
|
the value in this property. For tapes, it should be assumed
|
||
|
that no filemarks or blank space areas are recorded on the
|
||
|
Media."
|
||
|
::= { storageMediaLocationEntry 14 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-PhysicalMedia-MediaType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
other (1),
|
||
|
tape (2),
|
||
|
qic (3),
|
||
|
ait (4),
|
||
|
dtf (5),
|
||
|
dat (6),
|
||
|
eightmmTape (7),
|
||
|
nineteenmmTape (8),
|
||
|
dlt (9),
|
||
|
halfInchMO (10),
|
||
|
catridgeDisk (11),
|
||
|
jazDisk (12),
|
||
|
zipDisk (13),
|
||
|
syQuestDisk (14),
|
||
|
winchesterDisk (15),
|
||
|
cdRom (16),
|
||
|
cdRomXA (17),
|
||
|
cdI (18),
|
||
|
cdRecordable (19),
|
||
|
wORM (20),
|
||
|
magneto-Optical (21),
|
||
|
dvd (22),
|
||
|
dvdRWPlus (23),
|
||
|
dvdRAM (24),
|
||
|
dvdROM (25),
|
||
|
dvdVideo (26),
|
||
|
divx (27),
|
||
|
floppyDiskette (28),
|
||
|
hardDisk (29),
|
||
|
memoryCard (30),
|
||
|
hardCopy (31),
|
||
|
clikDisk (32),
|
||
|
cdRW (33),
|
||
|
cdDA (34),
|
||
|
cdPlus (35),
|
||
|
dvdRecordable (36),
|
||
|
dvdRW (37),
|
||
|
dvdAudio (38),
|
||
|
dvd5 (39),
|
||
|
dvd9 (40),
|
||
|
dvd10 (41),
|
||
|
dvd18 (42),
|
||
|
moRewriteable (43),
|
||
|
moWriteOnce (44),
|
||
|
moLIMDOW (45),
|
||
|
phaseChangeWO (46),
|
||
|
phaseChangeRewriteable (47),
|
||
|
phaseChangeDualRewriteable (48),
|
||
|
ablativeWriteOnce (49),
|
||
|
nearField (50),
|
||
|
miniQic (51),
|
||
|
travan (52),
|
||
|
eightmmMetal (53),
|
||
|
eightmmAdvanced (54),
|
||
|
nctp (55),
|
||
|
ltoUltrium (56),
|
||
|
ltoAccelis (57),
|
||
|
tape9Track (58),
|
||
|
tape18Track (59),
|
||
|
tape36Track (60),
|
||
|
magstar3590 (61),
|
||
|
magstarMP (62),
|
||
|
d2Tape (63),
|
||
|
dstSmall (64),
|
||
|
dstMedium (65),
|
||
|
dstLarge (66) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Specifies the type of the PhysicalMedia, as an
|
||
|
enumerated integer. The MediaDescription property is used to
|
||
|
provide more explicit definition of the Media type, whether it
|
||
|
is pre-formatted, compatability features, etc."
|
||
|
::= { storageMediaLocationEntry 15 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-PhysicalMedia-MediaDescription OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Additional detail related to the MediaType
|
||
|
enumeration. For example, if value 3 ('QIC Cartridge') is
|
||
|
specified, this property could indicate whether
|
||
|
the tape is wide or 1/4 inch, whether it is pre-formatted,
|
||
|
whether it is Travan compatible, etc."
|
||
|
::= { storageMediaLocationEntry 16 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-PhysicalMedia-CleanerMedia OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Boolean indicating that the PhysicalMedia is used
|
||
|
for cleaning purposes and not data storage."
|
||
|
::= { storageMediaLocationEntry 17 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-PhysicalMedia-DualSided OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown (0),
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Boolean indicating that the Media has two recording
|
||
|
sides (TRUE) or only a single side (FALSE). Examples of dual
|
||
|
sided Media include DVD-ROM and some optical disks. Examples of
|
||
|
single sided Media are tapes and CD-ROM."
|
||
|
::= { storageMediaLocationEntry 18 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-PhysicalMedia-PhysicalLabel OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"One or more strings on 'labels' on the PhysicalMedia.
|
||
|
The format of the labels and their state (readable, unreadable,
|
||
|
upside-down) are indicated in the LabelFormats and LabelStates
|
||
|
array properties."
|
||
|
::= { storageMediaLocationEntry 19 }
|
||
|
|
||
|
|
||
|
storageMediaLocation-PhysicalMedia-Tag OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An arbitrary string that uniquely identifies the
|
||
|
Physical Element and serves as the Element's key. The Tag
|
||
|
property can contain information such as asset tag or serial
|
||
|
data. The key for PhysicalElement is placed very high in
|
||
|
number the object hierarchy in order to independently identify
|
||
|
the hardware/entity, regardless of physical placement in or on
|
||
|
Cabinets, Adapters, etc. For example, a hotswappable or
|
||
|
removeable component may be taken from its containing
|
||
|
(scoping) Package and be temporarily unused. The object
|
||
|
still continues to exist - and may even be inserted into a
|
||
|
different scoping container. Therefore, the key for
|
||
|
Physical Element is an arbitrary string and is defined
|
||
|
independently of any placement or location-oriented
|
||
|
hierarchy."
|
||
|
::= { storageMediaLocationEntry 20 }
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
limitedAccessPortGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 14 }
|
||
|
|
||
|
numberOflimitedAccessPorts OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the number of limitedAccessPorts that are
|
||
|
present."
|
||
|
::= { limitedAccessPortGroup 1 }
|
||
|
|
||
|
limitedAccessPortTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF LimitedAccessPort-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The limitedAccessPort class represents limitedAccessPorts in the
|
||
|
library"
|
||
|
::= { limitedAccessPortGroup 2 }
|
||
|
|
||
|
limitedAccessPortEntry OBJECT-TYPE
|
||
|
SYNTAX LimitedAccessPort-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Each entry in the table contains information about a
|
||
|
limitedAccessPort that is present in the library."
|
||
|
INDEX { limitedAccessPortIndex }
|
||
|
::= { limitedAccessPortTable 1 }
|
||
|
|
||
|
LimitedAccessPort-Table-Info ::= SEQUENCE {
|
||
|
limitedAccessPortIndex UINT32,
|
||
|
limitedAccessPort-DeviceID DisplayString,
|
||
|
limitedAccessPort-Extended INTEGER,
|
||
|
limitedAccessPort-ElementName DisplayString,
|
||
|
limitedAccessPort-Caption DisplayString,
|
||
|
limitedAccessPort-Description DisplayString,
|
||
|
limitedAccessPort-Realizes-StorageLocationIndex UINT32
|
||
|
}
|
||
|
|
||
|
|
||
|
limitedAccessPortIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the limitedAccessPort."
|
||
|
::= { limitedAccessPortEntry 1 }
|
||
|
|
||
|
|
||
|
limitedAccessPort-DeviceID OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An address or other identifying information to
|
||
|
uniquely name the LogicalDevice."
|
||
|
::= { limitedAccessPortEntry 2 }
|
||
|
|
||
|
|
||
|
limitedAccessPort-Extended OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
true (1),
|
||
|
false (2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"When a Port is 'Extended' or 'open' (value=TRUE), its
|
||
|
Storage MediaLocations are accessible to a human operator.
|
||
|
If not extended (value=FALSE), the Locations are accessible
|
||
|
to a PickerElement."
|
||
|
::= { limitedAccessPortEntry 3 }
|
||
|
|
||
|
|
||
|
limitedAccessPort-ElementName OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A user-friendly name for the object. This property
|
||
|
allows each instance to define a user-friendly name IN ADDITION
|
||
|
TO its key properties/identity data, and description
|
||
|
information.
|
||
|
Note that ManagedSystemElement's Name property is also
|
||
|
defined as a user-friendly name. But, it is often
|
||
|
subclassed to be a Key. It is not reasonable that the same
|
||
|
property can convey both identity and a user friendly name,
|
||
|
without inconsistencies. Where Name exists and is not a Key
|
||
|
(such as for instances of LogicalDevice), the same
|
||
|
information MAY be present in both the Name and ElementName
|
||
|
properties."
|
||
|
::= { limitedAccessPortEntry 4 }
|
||
|
|
||
|
|
||
|
limitedAccessPort-Caption OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Caption property is a short textual description
|
||
|
(one- line string) of the object."
|
||
|
::= { limitedAccessPortEntry 5 }
|
||
|
|
||
|
|
||
|
limitedAccessPort-Description OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Description property provides a textual
|
||
|
description of the object."
|
||
|
::= { limitedAccessPortEntry 6 }
|
||
|
|
||
|
|
||
|
limitedAccessPort-Realizes-StorageLocationIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the
|
||
|
storageMediaLocationIndex that this limitedAccessPort is
|
||
|
associated with.
|
||
|
If no association exists an index of 0 may be returned."
|
||
|
::= { limitedAccessPortEntry 7 }
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
fCPortGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 15 }
|
||
|
|
||
|
numberOffCPorts OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the number of fcPorts that are
|
||
|
present."
|
||
|
::= { fCPortGroup 1 }
|
||
|
|
||
|
fCPortTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF FCPortPort-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The fcPort class represents Fibre Channel Ports in the library"
|
||
|
::= { fCPortGroup 2 }
|
||
|
|
||
|
fCPortEntry OBJECT-TYPE
|
||
|
SYNTAX FCPortPort-Table-Info
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Each entry in the table contains information about an
|
||
|
fcPort that is present in the library."
|
||
|
INDEX { fCPortIndex }
|
||
|
::= { fCPortTable 1 }
|
||
|
|
||
|
FCPortPort-Table-Info ::= SEQUENCE {
|
||
|
fCPortIndex UINT32,
|
||
|
fCPort-DeviceID DisplayString,
|
||
|
fCPort-ElementName DisplayString,
|
||
|
fCPort-Caption DisplayString,
|
||
|
fCPort-Description DisplayString,
|
||
|
fCPortController-OperationalStatus INTEGER,
|
||
|
fCPort-PermanentAddress DisplayString,
|
||
|
fCPort-Realizes-scsiProtocolControllerIndex UINT32
|
||
|
}
|
||
|
|
||
|
|
||
|
fCPortIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the fCPort."
|
||
|
::= { fCPortEntry 1 }
|
||
|
|
||
|
|
||
|
fCPort-DeviceID OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An address or other identifying information to
|
||
|
uniquely name the LogicalDevice."
|
||
|
::= { fCPortEntry 2 }
|
||
|
|
||
|
|
||
|
fCPort-ElementName OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A user-friendly name for the object. This property
|
||
|
allows each instance to define a user-friendly name IN ADDITION
|
||
|
TO its key properties/identity data, and description
|
||
|
information.
|
||
|
Note that ManagedSystemElement's Name property is also
|
||
|
defined as a user-friendly name. But, it is often
|
||
|
subclassed to be a Key. It is not reasonable that the same
|
||
|
property can convey both identity and a user friendly name,
|
||
|
without inconsistencies. Where Name exists and is not a Key
|
||
|
(such as for instances of LogicalDevice), the same
|
||
|
information MAY be present in both the Name and ElementName
|
||
|
properties."
|
||
|
::= { fCPortEntry 3 }
|
||
|
|
||
|
|
||
|
fCPort-Caption OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Caption property is a short textual description
|
||
|
(one- line string) of the object."
|
||
|
::= { fCPortEntry 4 }
|
||
|
|
||
|
|
||
|
fCPort-Description OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Description property provides a textual
|
||
|
description of the object."
|
||
|
::= { fCPortEntry 5 }
|
||
|
|
||
|
|
||
|
fCPortController-OperationalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { unknown (0),
|
||
|
other (1),
|
||
|
ok (2),
|
||
|
degraded (3),
|
||
|
stressed (4),
|
||
|
predictiveFailure (5),
|
||
|
error (6),
|
||
|
non-RecoverableError (7),
|
||
|
starting (8),
|
||
|
stopping (9),
|
||
|
stopped (10),
|
||
|
inService (11),
|
||
|
noContact (12),
|
||
|
lostCommunication (13),
|
||
|
aborted (14),
|
||
|
dormant (15),
|
||
|
supportingEntityInError (16),
|
||
|
completed (17),
|
||
|
powerMode (18),
|
||
|
dMTFReserved (19),
|
||
|
vendorReserved (32768) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Indicates the current status(es) of the element.
|
||
|
Various health and operational statuses are defined. Many of
|
||
|
the enumeration's values are self- explanatory. However, a few
|
||
|
are not and are described in more detail. \n
|
||
|
'Stressed' indicates that the element is functioning, but
|
||
|
needs attention. Examples of 'Stressed' states are
|
||
|
overload, overheated, etc. \n
|
||
|
'Predictive Failure' indicates that an element is
|
||
|
functioning nominally but predicting a failure in the near
|
||
|
future. \n
|
||
|
'In Service' describes an element being configured,
|
||
|
maintained, cleaned, or otherwise administered. \n
|
||
|
'No Contact' indicates that the monitoring system has
|
||
|
knowledge of this element, but has never been able to
|
||
|
establish communications with it. \n
|
||
|
'Lost Communication' indicates that the ManagedSystem
|
||
|
Element is known to exist and has been contacted
|
||
|
successfully in the past, but is currently unreachable. \n
|
||
|
'Stopped' and 'Aborted' are similar, although the
|
||
|
former implies a clean and orderly stop, while the latter
|
||
|
implies an abrupt stop where the element's state and
|
||
|
configuration may need to be updated. \n
|
||
|
'Dormant' indicates that the element is inactive or
|
||
|
quiesced. \n
|
||
|
'Supporting Entity in Error' describes that this element
|
||
|
may be 'OK' but that another element, on which it is
|
||
|
dependent, is in error. An example is a network service or
|
||
|
endpoint that cannot function due to lower layer networking
|
||
|
problems. \n
|
||
|
'Completed' indicates the element has completed its
|
||
|
operation. This value should be combined with either OK,
|
||
|
Error, or Degraded so that a client can till if the
|
||
|
complete operation passed (Completed with OK), and failure
|
||
|
(Completed with Error). Completed with Degraded would imply
|
||
|
the operation finished, but did not complete OK or report
|
||
|
an error. \n
|
||
|
'Power Mode' indicates the element has additional power
|
||
|
model information contained in the Associated
|
||
|
PowerManagementService association. \n
|
||
|
OperationalStatus replaces the Status property on
|
||
|
ManagedSystemElement to provide a consistent approach to
|
||
|
enumerations, to address implementation needs for an array
|
||
|
property, and to provide a migration path from today's
|
||
|
environment to the future. This change was not made earlier
|
||
|
since it required the DEPRECATED qualifier. Due to the
|
||
|
widespread use of the existing Status property in
|
||
|
management applications, it is strongly RECOMMENDED that
|
||
|
providers/instrumentation provide BOTH the Status and
|
||
|
OperationalStatus properties. Further, the first value of
|
||
|
OperationalStatus SHOULD contain the primary status for the
|
||
|
element. When instrumented, Status (since it is
|
||
|
single-valued) SHOULD also provide the primary status of
|
||
|
the element.
|
||
|
|
||
|
SMI-S 1.1 Section 8.1.2.2.3 additional description for FC Ports
|
||
|
OK - Port is online
|
||
|
Error - Port has a failure
|
||
|
Stopped - Port is disabled
|
||
|
InService - Port is in Self Test
|
||
|
Unknown"
|
||
|
::= { fCPortEntry 6 }
|
||
|
|
||
|
|
||
|
fCPort-PermanentAddress OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"PermanentAddress defines the network address
|
||
|
hardcoded into a port. This 'hardcoded' address may be changed
|
||
|
via firmware upgrade or software configuration. If so, this
|
||
|
field should be updated when the change is made.
|
||
|
PermanentAddress should be left blank if no 'hardcoded'
|
||
|
address exists for the NetworkAdapter.
|
||
|
|
||
|
In SMI-S 1.1 table 1304 FCPorts are defined to use the port WWN
|
||
|
as described in table 7.2.4.5.2
|
||
|
|
||
|
World Wide Name (i.e. FC Name_Identifier) FCPort
|
||
|
Permanent Address property; no corresponding
|
||
|
format property 16 un-separated upper case hex
|
||
|
digits (e.g. '21000020372D3C73')"
|
||
|
::= { fCPortEntry 7 }
|
||
|
|
||
|
|
||
|
fCPort-Realizes-scsiProtocolControllerIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the
|
||
|
scsiProtocolControllerIndex that this fCPort is associated with.
|
||
|
If no association exists an index of 0 may be returned."
|
||
|
::= { fCPortEntry 8 }
|
||
|
|
||
|
|
||
|
|
||
|
-- Traps are based on the T10 Tape Alert Specification v3 (w/SSC-3 Enhancements)
|
||
|
-- and SMI-S 1.1 section 8.1.8.25 LibraryAlert Events/Indications
|
||
|
|
||
|
trapGroup OBJECT IDENTIFIER
|
||
|
::= { smlRoot 16 }
|
||
|
|
||
|
trapsEnabled OBJECT-TYPE
|
||
|
SYNTAX INTEGER { enabled ( 1 ) , disabled ( 2 ) }
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Set to enable sending traps"
|
||
|
::= { trapGroup 1 }
|
||
|
|
||
|
trapDriveAlertSummary OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
readWarning ( 1 ) ,
|
||
|
writeWarning ( 2 ) ,
|
||
|
hardError ( 3 ) , media ( 4 ) , readFailure ( 5 ) ,
|
||
|
writeFailure ( 6 ) ,
|
||
|
mediaLife ( 7 ) ,
|
||
|
notDataGrade ( 8 ) ,
|
||
|
writeProtect ( 9 ) ,
|
||
|
noRemoval ( 10 ) ,
|
||
|
cleaningMedia ( 11 ) ,
|
||
|
unsupportedFormat ( 12 ) ,
|
||
|
recoverableSnappedTape ( 13 ) ,
|
||
|
unrecoverableSnappedTape ( 14 ) ,
|
||
|
memoryChipInCartridgeFailure ( 15 ) ,
|
||
|
forcedEject ( 16 ) ,
|
||
|
readOnlyFormat ( 17 ) ,
|
||
|
directoryCorruptedOnLoad ( 18 ) ,
|
||
|
nearingMediaLife ( 19 ) ,
|
||
|
cleanNow ( 20 ) ,
|
||
|
cleanPeriodic ( 21 ) ,
|
||
|
expiredCleaningMedia ( 22 ) ,
|
||
|
invalidCleaningMedia ( 23 ) ,
|
||
|
retentionRequested ( 24 ) ,
|
||
|
dualPortInterfaceError ( 25 ) ,
|
||
|
coolingFanError ( 26 ) ,
|
||
|
powerSupplyFailure ( 27 ) ,
|
||
|
powerConsumption ( 28 ) ,
|
||
|
driveMaintenance ( 29 ) ,
|
||
|
hardwareA ( 30 ) ,
|
||
|
hardwareB ( 31 ) ,
|
||
|
interface ( 32 ) ,
|
||
|
ejectMedia ( 33 ) ,
|
||
|
downloadFailure ( 34 ) ,
|
||
|
driveHumidity ( 35 ) ,
|
||
|
driveTemperature ( 36 ) ,
|
||
|
driveVoltage ( 37 ) ,
|
||
|
predictiveFailure ( 38 ) ,
|
||
|
diagnosticsRequired ( 39 ) ,
|
||
|
lostStatistics ( 50 ) ,
|
||
|
mediaDirectoryInvalidAtUnload ( 51 ) ,
|
||
|
mediaSystemAreaWriteFailure ( 52 ) ,
|
||
|
mediaSystemAreaReadFailure ( 53 ) ,
|
||
|
noStartOfData ( 54 ) ,
|
||
|
loadingFailure ( 55 ) ,
|
||
|
unrecoverableUnloadFailure ( 56 ) ,
|
||
|
automationInterfaceFailure ( 57 ) ,
|
||
|
firmwareFailure ( 58 ) ,
|
||
|
wormMediumIntegrityCheckFailed ( 59 ) ,
|
||
|
wormMediumOverwriteAttempted ( 60 ) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Short summary of a media (tape, optical, etc.) driveAlert trap.
|
||
|
Corresponds to the Number/Flag property of
|
||
|
drive/autoloader alerts in the T10 TapeAlert Specification v3
|
||
|
(w/SSC-3 Enhancements) as modified by the EventSummary property in
|
||
|
the SMI-S 1.1 section 8.1.8.25 LibraryAlert Events/Indications for
|
||
|
Library Devices. In particular, all occurances of 'tape' have been
|
||
|
replaced with 'media'. (This summary property has a 1 to 1
|
||
|
relationship to the CIM_AlertIndication.OtherAlertType property,
|
||
|
and might be stored in the CIM_AlertIndication.Message property.)"
|
||
|
::= { trapGroup 2 }
|
||
|
|
||
|
trap-Association-MediaAccessDeviceIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the MediaAccessDeviceIndex
|
||
|
that this changerAlert trap is associated with.
|
||
|
If no association exists an index of 0 may be returned. "
|
||
|
::= { trapGroup 3 }
|
||
|
|
||
|
|
||
|
trapChangerAlertSummary OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
libraryHardwareA ( 1 ) ,
|
||
|
libraryHardwareB ( 2 ) ,
|
||
|
libraryHardwareC ( 3 ) ,
|
||
|
libraryHardwareD ( 4 ) ,
|
||
|
libraryDiagnosticsRequired ( 5 ) ,
|
||
|
libraryInterface ( 6 ) ,
|
||
|
failurePrediction ( 7 ) ,
|
||
|
libraryMaintenance ( 8 ) ,
|
||
|
libraryHumidityLimits ( 9 ) ,
|
||
|
libraryTemperatureLimits ( 10 ) ,
|
||
|
libraryVoltageLimits ( 11 ) ,
|
||
|
libraryStrayMedia ( 12 ) ,
|
||
|
libraryPickRetry ( 13 ) ,
|
||
|
libraryPlaceRetry ( 14 ) ,
|
||
|
libraryLoadRetry ( 15 ) ,
|
||
|
libraryDoor ( 16 ) ,
|
||
|
libraryMailslot ( 17 ) ,
|
||
|
libraryMagazine ( 18 ) ,
|
||
|
librarySecurity ( 19 ) ,
|
||
|
librarySecurityMode ( 20 ) ,
|
||
|
libraryOffline ( 21 ) ,
|
||
|
libraryDriveOffline ( 22 ) ,
|
||
|
libraryScanRetry ( 23 ) ,
|
||
|
libraryInventory ( 24 ) ,
|
||
|
libraryIllegalOperation ( 25 ) ,
|
||
|
dualPortInterfaceError ( 26 ) ,
|
||
|
coolingFanFailure ( 27 ) ,
|
||
|
powerSupply ( 28 ) ,
|
||
|
powerConsumption ( 29 ) ,
|
||
|
passThroughMechanismFailure ( 30 ) ,
|
||
|
cartridgeInPassThroughMechanism ( 31 ) ,
|
||
|
unreadableBarCodeLabels ( 32 ) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Short summary of a changer (eg. robot) changerAlert trap.
|
||
|
Corresponds to the Number/Flag property of stand-alone
|
||
|
changer alerts in the T10 TapeAlert Specification v3 (w/SSC-3
|
||
|
Enhancements) as modified by the EventSummary property in the
|
||
|
SMI-S 1.1 section 8.1.8.25 LibraryAlert Events/Indications for
|
||
|
Library Devices. In particular, all occurances of 'tape' have been
|
||
|
replaced with 'media'. (This summary property has a 1 to 1
|
||
|
relationship to the CIM_AlertIndication.OtherAlertType property,
|
||
|
and might be stored in the CIM_AlertIndication.Message property.)"
|
||
|
::= { trapGroup 4 }
|
||
|
|
||
|
trap-Association-ChangerDeviceIndex OBJECT-TYPE
|
||
|
SYNTAX UINT32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current index value for the ChangerDeviceIndex
|
||
|
that this changerAlert trap is associated with.
|
||
|
If no association exists an index of 0 may be returned. "
|
||
|
::= { trapGroup 5 }
|
||
|
|
||
|
|
||
|
trapPerceivedSeverity OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown ( 0 ) ,
|
||
|
other ( 1 ) ,
|
||
|
information ( 2 ) ,
|
||
|
degradedWarning ( 3 ) ,
|
||
|
minor ( 4 ) ,
|
||
|
major ( 5 ) ,
|
||
|
critical ( 6 ) ,
|
||
|
fatalNonRecoverable ( 7 ) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An enumerated value that describes the severity of
|
||
|
the Alert Indication from the notifier's point of view: 1 - Other,
|
||
|
by CIM convention, is used to indicate that the Severity's value
|
||
|
can be found in the OtherSeverity property. 3 - Degraded/Warning
|
||
|
should be used when its appropriate to let the user decide if
|
||
|
action is needed. 4 - Minor should be used to indicate action is
|
||
|
needed, but the situation is not serious at this time. 5 - Major
|
||
|
should be used to indicate action is needed NOW. 6 - Critical
|
||
|
should be used to indicate action is needed NOW and the scope is
|
||
|
broad (perhaps an imminent outage to a critical resource will
|
||
|
result). 7 - Fatal/NonRecoverable should be used to indicate an
|
||
|
error occurred, but it's too late to take remedial action.
|
||
|
2 and 0 - Information and Unknown (respectively) follow common
|
||
|
usage. Literally, the AlertIndication is purely informational
|
||
|
or its severity is simply unknown. This would have values
|
||
|
described in SMI-S 1.1 section 8.1.8.25 LibraryAlert
|
||
|
Events/Indications for Library Devices, the PerceivedSeverity
|
||
|
column. These values are a superset of the Info/Warning/Critical
|
||
|
values in the T10 TapeAlert Specification v3 (w/SSC-3 Enhancements)
|
||
|
, and an SNMP agent may choose to only specify those if that's all
|
||
|
that's available. (This corresponds to the
|
||
|
CIM_AlertIndication.PerceivedSeverity property.)"
|
||
|
::= { trapGroup 6 }
|
||
|
|
||
|
trapDestinationTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF TrapDestinationEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Table of client/manager desitinations which will receive
|
||
|
traps"
|
||
|
::= { trapGroup 7 }
|
||
|
|
||
|
trapDestinationEntry OBJECT-TYPE
|
||
|
SYNTAX TrapDestinationEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Entry containing information needed to send traps to an
|
||
|
SNMP client/manager"
|
||
|
INDEX { numberOfTrapDestinations }
|
||
|
::= { trapDestinationTable 1 }
|
||
|
|
||
|
TrapDestinationEntry ::= SEQUENCE {
|
||
|
numberOfTrapDestinations Integer32,
|
||
|
trapDestinationHostType INTEGER,
|
||
|
trapDestinationHostAddr DisplayString,
|
||
|
trapDestinationPort Integer32
|
||
|
}
|
||
|
|
||
|
|
||
|
numberOfTrapDestinations OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the number of trap destination
|
||
|
SNMP clients/managers."
|
||
|
::= { trapDestinationEntry 1 }
|
||
|
|
||
|
|
||
|
trapDestinationHostType OBJECT-TYPE
|
||
|
SYNTAX INTEGER { iPv4 ( 1 ) , iPv6 ( 2 ) }
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The type of addressing model to represent the
|
||
|
network address (IPv4/IPv6)"
|
||
|
::= { trapDestinationEntry 2 }
|
||
|
|
||
|
|
||
|
trapDestinationHostAddr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The network address of this client/manager, to
|
||
|
which the trap should be sent"
|
||
|
::= { trapDestinationEntry 3 }
|
||
|
|
||
|
|
||
|
trapDestinationPort OBJECT-TYPE
|
||
|
SYNTAX Integer32 ( 0 .. 65535 )
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The port number where this client/manager is
|
||
|
listening for traps."
|
||
|
::= { trapDestinationEntry 4 }
|
||
|
|
||
|
|
||
|
driveAlert TRAP-TYPE
|
||
|
ENTERPRISE smlRoot
|
||
|
VARIABLES {
|
||
|
trapDriveAlertSummary,
|
||
|
trap-Association-MediaAccessDeviceIndex,
|
||
|
trapPerceivedSeverity }
|
||
|
DESCRIPTION
|
||
|
"A Drive/Autoloader Alert trap, based on the T10 TapeAlert
|
||
|
Specification v3 (w/SSC-3 Enhancements) and SMI-S 1.1 section
|
||
|
8.1.8.25 LibraryAlert Events/Indications."
|
||
|
::= 0
|
||
|
|
||
|
changerAlert TRAP-TYPE
|
||
|
ENTERPRISE smlRoot
|
||
|
VARIABLES {
|
||
|
trapChangerAlertSummary,
|
||
|
trap-Association-ChangerDeviceIndex,
|
||
|
trapPerceivedSeverity }
|
||
|
DESCRIPTION
|
||
|
"A Changer Device (eg. robot) Alert trap, based on the T10 TapeAlert
|
||
|
Specification v3 (w/SSC-3 Enhancements) and SMI-S 1.1 section
|
||
|
8.1.8.25 LibraryAlert Events/Indications."
|
||
|
::= 1
|
||
|
|
||
|
trapObjects OBJECT IDENTIFIER ::= { trapGroup 8 }
|
||
|
|
||
|
currentOperationalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { unknown (0),
|
||
|
other (1),
|
||
|
ok (2),
|
||
|
degraded (3),
|
||
|
stressed (4),
|
||
|
predictiveFailure (5),
|
||
|
error (6),
|
||
|
non-RecoverableError (7),
|
||
|
starting (8),
|
||
|
stopping (9),
|
||
|
stopped (10),
|
||
|
inService (11),
|
||
|
noContact (12),
|
||
|
lostCommunication (13),
|
||
|
aborted (14),
|
||
|
dormant (15),
|
||
|
supportingEntityInError (16),
|
||
|
completed (17),
|
||
|
powerMode (18),
|
||
|
dMTFReserved (19),
|
||
|
vendorReserved (32768) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Indicates the previous status(es) of the element.
|
||
|
Various health and operational statuses are defined. Many of
|
||
|
the enumeration's values are self- explanatory. However, a few
|
||
|
are not and are described in more detail. \n
|
||
|
'Stressed' indicates that the element is functioning, but
|
||
|
needs attention. Examples of 'Stressed' states are
|
||
|
overload, overheated, etc. \n
|
||
|
'Predictive Failure' indicates that an element is
|
||
|
functioning nominally but predicting a failure in the near
|
||
|
future. \n
|
||
|
'In Service' describes an element being configured,
|
||
|
maintained, cleaned, or otherwise administered. \n
|
||
|
'No Contact' indicates that the monitoring system has
|
||
|
knowledge of this element, but has never been able to
|
||
|
establish communications with it. \n
|
||
|
'Lost Communication' indicates that the ManagedSystem
|
||
|
Element is known to exist and has been contacted
|
||
|
successfully in the past, but is currently unreachable. \n
|
||
|
'Stopped' and 'Aborted' are similar, although the
|
||
|
former implies a clean and orderly stop, while the latter
|
||
|
implies an abrupt stop where the element's state and
|
||
|
configuration may need to be updated. \n
|
||
|
'Dormant' indicates that the element is inactive or
|
||
|
quiesced. \n
|
||
|
'Supporting Entity in Error' describes that this element
|
||
|
may be 'OK' but that another element, on which it is
|
||
|
dependent, is in error. An example is a network service or
|
||
|
endpoint that cannot function due to lower layer networking
|
||
|
problems. \n
|
||
|
'Completed' indicates the element has completed its
|
||
|
operation. This value should be combined with either OK,
|
||
|
Error, or Degraded so that a client can till if the
|
||
|
complete operation passed (Completed with OK), and failure
|
||
|
(Completed with Error). Completed with Degraded would imply
|
||
|
the operation finished, but did not complete OK or report
|
||
|
an error. \n
|
||
|
'Power Mode' indicates the element has additional power
|
||
|
model information contained in the Associated
|
||
|
PowerManagementService association. \n
|
||
|
OperationalStatus replaces the Status property on
|
||
|
ManagedSystemElement to provide a consistent approach to
|
||
|
enumerations, to address implementation needs for an array
|
||
|
property, and to provide a migration path from today's
|
||
|
environment to the future. This change was not made earlier
|
||
|
since it required the DEPRECATED qualifier. Due to the
|
||
|
widespread use of the existing Status property in
|
||
|
management applications, it is strongly RECOMMENDED that
|
||
|
providers/instrumentation provide BOTH the Status and
|
||
|
OperationalStatus properties. Further, the first value of
|
||
|
OperationalStatus SHOULD contain the primary status for the
|
||
|
element. When instrumented, Status (since it is
|
||
|
single-valued) SHOULD also provide the primary status of
|
||
|
the element."
|
||
|
::= { trapObjects 1 }
|
||
|
|
||
|
oldOperationalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER { unknown (0),
|
||
|
other (1),
|
||
|
ok (2),
|
||
|
degraded (3),
|
||
|
stressed (4),
|
||
|
predictiveFailure (5),
|
||
|
error (6),
|
||
|
non-RecoverableError (7),
|
||
|
starting (8),
|
||
|
stopping (9),
|
||
|
stopped (10),
|
||
|
inService (11),
|
||
|
noContact (12),
|
||
|
lostCommunication (13),
|
||
|
aborted (14),
|
||
|
dormant (15),
|
||
|
supportingEntityInError (16),
|
||
|
completed (17),
|
||
|
powerMode (18),
|
||
|
dMTFReserved (19),
|
||
|
vendorReserved (32768) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Indicates the previous status(es) of the element.
|
||
|
Various health and operational statuses are defined. Many of
|
||
|
the enumeration's values are self- explanatory. However, a few
|
||
|
are not and are described in more detail. \n
|
||
|
'Stressed' indicates that the element is functioning, but
|
||
|
needs attention. Examples of 'Stressed' states are
|
||
|
overload, overheated, etc. \n
|
||
|
'Predictive Failure' indicates that an element is
|
||
|
functioning nominally but predicting a failure in the near
|
||
|
future. \n
|
||
|
'In Service' describes an element being configured,
|
||
|
maintained, cleaned, or otherwise administered. \n
|
||
|
'No Contact' indicates that the monitoring system has
|
||
|
knowledge of this element, but has never been able to
|
||
|
establish communications with it. \n
|
||
|
'Lost Communication' indicates that the ManagedSystem
|
||
|
Element is known to exist and has been contacted
|
||
|
successfully in the past, but is currently unreachable. \n
|
||
|
'Stopped' and 'Aborted' are similar, although the
|
||
|
former implies a clean and orderly stop, while the latter
|
||
|
implies an abrupt stop where the element's state and
|
||
|
configuration may need to be updated. \n
|
||
|
'Dormant' indicates that the element is inactive or
|
||
|
quiesced. \n
|
||
|
'Supporting Entity in Error' describes that this element
|
||
|
may be 'OK' but that another element, on which it is
|
||
|
dependent, is in error. An example is a network service or
|
||
|
endpoint that cannot function due to lower layer networking
|
||
|
problems. \n
|
||
|
'Completed' indicates the element has completed its
|
||
|
operation. This value should be combined with either OK,
|
||
|
Error, or Degraded so that a client can till if the
|
||
|
complete operation passed (Completed with OK), and failure
|
||
|
(Completed with Error). Completed with Degraded would imply
|
||
|
the operation finished, but did not complete OK or report
|
||
|
an error. \n
|
||
|
'Power Mode' indicates the element has additional power
|
||
|
model information contained in the Associated
|
||
|
PowerManagementService association. \n
|
||
|
OperationalStatus replaces the Status property on
|
||
|
ManagedSystemElement to provide a consistent approach to
|
||
|
enumerations, to address implementation needs for an array
|
||
|
property, and to provide a migration path from today's
|
||
|
environment to the future. This change was not made earlier
|
||
|
since it required the DEPRECATED qualifier. Due to the
|
||
|
widespread use of the existing Status property in
|
||
|
management applications, it is strongly RECOMMENDED that
|
||
|
providers/instrumentation provide BOTH the Status and
|
||
|
OperationalStatus properties. Further, the first value of
|
||
|
OperationalStatus SHOULD contain the primary status for the
|
||
|
element. When instrumented, Status (since it is
|
||
|
single-valued) SHOULD also provide the primary status of
|
||
|
the element."
|
||
|
::= { trapObjects 2 }
|
||
|
|
||
|
libraryAddedTrap TRAP-TYPE
|
||
|
ENTERPRISE trapGroup
|
||
|
VARIABLES {
|
||
|
storageLibrary-Name
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"A library is added to the SMI-S agent.
|
||
|
This trap is to support the SMI-S 1.1 section 8.1.8.23 InstCreation
|
||
|
indication."
|
||
|
::= 3
|
||
|
|
||
|
libraryDeletedTrap TRAP-TYPE
|
||
|
ENTERPRISE trapGroup
|
||
|
VARIABLES {
|
||
|
storageLibrary-Name
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"A library is deleted in the SMI-S agent.
|
||
|
This trap is to support the SMI-S 1.1 section 8.1.8.23 InstDeletion
|
||
|
indication."
|
||
|
::= 4
|
||
|
|
||
|
libraryOpStatusChangedTrap TRAP-TYPE
|
||
|
ENTERPRISE trapGroup
|
||
|
VARIABLES {
|
||
|
storageLibrary-Name,
|
||
|
currentOperationalStatus,
|
||
|
oldOperationalStatus
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"A library OperationalStatus has changed in the SMI-S agent.
|
||
|
This trap is to support the SMI-S 1.1 section 8.1.8.23 InstModification
|
||
|
indication."
|
||
|
::= 5
|
||
|
|
||
|
driveAddedTrap TRAP-TYPE
|
||
|
ENTERPRISE trapGroup
|
||
|
VARIABLES {
|
||
|
storageLibrary-Name,
|
||
|
mediaAccessDevice-DeviceID
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"A media access device (trap drive) is added to the library.
|
||
|
This trap is to support the SMI-S 1.1 section 8.1.8.25 InstCreation
|
||
|
indication."
|
||
|
::= 6
|
||
|
|
||
|
driveDeletedTrap TRAP-TYPE
|
||
|
ENTERPRISE trapGroup
|
||
|
VARIABLES {
|
||
|
storageLibrary-Name,
|
||
|
mediaAccessDevice-DeviceID
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"A media access device (trap drive) is deleted from the library.
|
||
|
This trap is to support the SMI-S 1.1 section 8.1.8.25 InstDeletion
|
||
|
indication."
|
||
|
::= 7
|
||
|
|
||
|
driveOpStatusChangedTrap TRAP-TYPE
|
||
|
ENTERPRISE trapGroup
|
||
|
VARIABLES {
|
||
|
storageLibrary-Name,
|
||
|
mediaAccessDevice-DeviceID,
|
||
|
currentOperationalStatus,
|
||
|
oldOperationalStatus
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"A drive OperationalStatus has changed in the SMI-S agent.
|
||
|
This trap is to support the SMI-S 1.1 section 8.1.8.23 InstModification
|
||
|
indication."
|
||
|
::= 8
|
||
|
|
||
|
changerAddedTrap TRAP-TYPE
|
||
|
ENTERPRISE trapGroup
|
||
|
VARIABLES {
|
||
|
storageLibrary-Name,
|
||
|
changerDevice-DeviceID
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"A changer device is added to the library.
|
||
|
This trap is to support the SMI-S 1.1 section 8.1.8.25 InstCreation
|
||
|
indication."
|
||
|
::= 9
|
||
|
|
||
|
changerDeletedTrap TRAP-TYPE
|
||
|
ENTERPRISE trapGroup
|
||
|
VARIABLES {
|
||
|
storageLibrary-Name,
|
||
|
changerDevice-DeviceID
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"A changer device is deleted from the library.
|
||
|
This trap is to support the SMI-S 1.1 section 8.1.8.25 InstDeletion
|
||
|
indication."
|
||
|
::= 10
|
||
|
|
||
|
changerOpStatusChangedTrap TRAP-TYPE
|
||
|
ENTERPRISE trapGroup
|
||
|
VARIABLES {
|
||
|
storageLibrary-Name,
|
||
|
changerDevice-DeviceID,
|
||
|
currentOperationalStatus,
|
||
|
oldOperationalStatus
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"A changer OperationalStatus has changed in the SMI-S agent.
|
||
|
This trap is to support the SMI-S 1.1 section 8.1.8.23 InstModification
|
||
|
indication."
|
||
|
::= 11
|
||
|
|
||
|
physicalMediaAddedTrap TRAP-TYPE
|
||
|
ENTERPRISE trapGroup
|
||
|
VARIABLES {
|
||
|
storageMediaLocation-PhysicalMedia-Tag
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"A physical media is added to the library.
|
||
|
This trap is to support the SMI-S 1.1 section 8.1.8.25 InstCreation
|
||
|
indication."
|
||
|
::= 12
|
||
|
|
||
|
physicalMediaDeletedTrap TRAP-TYPE
|
||
|
ENTERPRISE trapGroup
|
||
|
VARIABLES {
|
||
|
storageMediaLocation-PhysicalMedia-Tag
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"A physical media is deleted from the library.
|
||
|
This trap is to support the SMI-S 1.1 section 8.1.8.25 InstDeletion
|
||
|
indication."
|
||
|
::= 13
|
||
|
|
||
|
endOfSmlMib OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Description here"
|
||
|
::= { smlRoot 17 }
|
||
|
|
||
|