LUM-OA-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32
FROM SNMPv2-SMI
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
DisplayString, DateAndTime, TruthValue
FROM SNMPv2-TC
lumModules, lumOaMIB
FROM LUM-REG
FaultStatus, MgmtNameString, SubrackNumber, SlotNumber, PortNumber,
LambdaFrequency, BoardOrInterfaceOperStatus, BoardOrInterfaceAdminStatus,
CommandString, ObjectProperty
FROM LUM-TC;
lumOaMIBModule MODULE-IDENTITY
LAST-UPDATED
"201906280000Z" -- June 28th 2019
ORGANIZATION
"Infinera Corporation"
CONTACT-INFO
"techsupport@infinera.com"
DESCRIPTION
"The optical amplifier interface MIB.
- General
- Amplifier interfaces
"
REVISION
"201906280000Z" -- June 28th 2019
DESCRIPTION
"Changes for release r33.0:
- laserForcedOn set to be persistent"
REVISION
"201706150000Z" -- June 15th 2017
DESCRIPTION
"Changes made for release r29.0:
- Changed ORGANIZATION and CONTACT-INFO"
REVISION
"201611300000Z" -- November 30th 2016
DESCRIPTION
"Changes made for release r28:
- Changes for Finisar ROADM: new alarms moduleWarmingUp and
moduleFailure added (moduleFailure previously in roadmAddDropIf).
- VCOM threshold is exceeded alarm removed."
REVISION
"201605300000Z" -- May 30th 2016
DESCRIPTION
"Changes made for release r27:
- Output power failed alarm added.
- Default value of operStatus set to notPresent."
REVISION
"201405160000Z" -- May 16th 2014
DESCRIPTION
"Changes made for release r23:
- VCOM threshold is exceeded alarm added.
- Firmware upgrade available alarm added.
- Interface supports fetching monitor insertion loss added.
"
REVISION
"201211010000Z" -- November 20th 2012
DESCRIPTION
"Changes made for release r20:
"
REVISION
"201203300000Z" -- March 30th 2012
DESCRIPTION
"Changes made for release r19:
- Voa SFP attributes added."
REVISION
"201112200000Z" -- December 20th 2011
DESCRIPTION
"Changes made for release r18:
- MDU16 features included."
REVISION
"201104270000Z" -- April 27th 2011
DESCRIPTION
"Added new amplifiers."
REVISION
"200501270000Z" -- January 27th 2006
DESCRIPTION
"Added TS-1100 specific alarms."
REVISION
"200209020000Z" -- September 2nd 2002
DESCRIPTION
"The initial revision of this module."
::= { lumModules 20 }
-- ----------------------------------------------------
-- Conformance area, containing groups and complicance
-- specifications.
-- ----------------------------------------------------
lumOaConfs OBJECT IDENTIFIER ::= { lumOaMIB 1 }
lumOaGroups OBJECT IDENTIFIER ::= { lumOaConfs 1 }
lumOaCompl OBJECT IDENTIFIER ::= { lumOaConfs 2 }
lumOaMinimalGroups OBJECT IDENTIFIER ::= { lumOaConfs 3 }
lumOaMinimalCompl OBJECT IDENTIFIER ::= { lumOaConfs 4 }
-- ----------------------------------------------------
-- Root for objects in the oa MIB
-- ----------------------------------------------------
lumOaMIBObjects OBJECT IDENTIFIER ::= { lumOaMIB 2 }
-- ----------------------------------------------------
-- This MIB contains the following groups:
-- ----------------------------------------------------
oaGeneral OBJECT IDENTIFIER ::= { lumOaMIBObjects 1 }
oaIfList OBJECT IDENTIFIER ::= { lumOaMIBObjects 2 }
lumentisOaNotifications OBJECT IDENTIFIER ::= { lumOaMIBObjects 3 }
oaVoaIfList OBJECT IDENTIFIER ::= { lumOaMIBObjects 4 }
oaVoaClientIfList OBJECT IDENTIFIER ::= { lumOaMIBObjects 5 }
oaVoaLineIfList OBJECT IDENTIFIER ::= { lumOaMIBObjects 6 }
oaModuleList OBJECT IDENTIFIER ::= { lumOaMIBObjects 7 }
-- ----------------------------------------------------
-- Textual Conventions
-- ----------------------------------------------------
-- ----------------------------------------------------
-- General group
-- ----------------------------------------------------
oaGeneralLastChangeTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time when the configuration of the MIB
was last changed.
"
::= { oaGeneral 1 }
oaGeneralStateLastChangeTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time when the state of the MIB was last
changed.
"
::= { oaGeneral 2 }
oaGeneralOaIfTableSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Size of table
"
::= { oaGeneral 3 }
oaGeneralVoaIfTableSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Size of table
"
::= { oaGeneral 4 }
oaGeneralVoaClientIfTableSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Size of table
"
::= { oaGeneral 5 }
oaGeneralVoaLineIfTableSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Size of table
"
::= { oaGeneral 6 }
oaGeneralOaModuleTableSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Size of table
"
::= { oaGeneral 7 }
-- ----------------------------------------------------
-- Optical amplifier interfaces
-- ----------------------------------------------------
oaIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface list."
::= { oaIfList 1 }
oaIfEntry OBJECT-TYPE
SYNTAX OaIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the interface list.
"
INDEX { oaIfIndex }
::= { oaIfTable 1 }
OaIfEntry ::=
SEQUENCE {
oaIfIndex Unsigned32,
oaIfName MgmtNameString,
oaIfDescr DisplayString,
oaIfSubrack SubrackNumber,
oaIfSlot SlotNumber,
oaIfTxPort PortNumber,
oaIfRxPort PortNumber,
oaIfInvPhysIndexOrZero Unsigned32,
oaIfAdminStatus BoardOrInterfaceAdminStatus,
oaIfOperStatus BoardOrInterfaceOperStatus,
oaIfLaserStatus INTEGER,
oaIfAmplifierType INTEGER,
oaIfWantedAbsolutePowerLevel Integer32,
oaIfWantedRelativePowerLevel Integer32,
oaIfWantedGain Integer32,
oaIfFrequencyMin LambdaFrequency,
oaIfFrequencyMax LambdaFrequency,
oaIfNominalTxPower Integer32,
oaIfTxPowerLevel Integer32,
oaIfRxPowerLevel Integer32,
oaIfRxPowerLevelLowThreshold Integer32,
oaIfLaserBias Unsigned32,
oaIfNominalLaserTemp Unsigned32,
oaIfRelativeLaserTemp Integer32,
oaIfLossOfSignalThreshold Integer32,
oaIfLossOfSignal FaultStatus,
oaIfPumpLaserTempHigh FaultStatus,
oaIfRegulationProblemRxPowerHigh FaultStatus,
oaIfRegulationProblemTxPowerHigh FaultStatus,
oaIfRegulationProblemTxPowerLow FaultStatus,
oaIfReceivedPowerLow FaultStatus,
oaIfLaserBiasHigh FaultStatus,
oaIfLaserTempControlFault FaultStatus,
oaIfHwMissing FaultStatus,
oaIfConfigurationCommand CommandString,
oaIfPumpLaserTempLow FaultStatus,
oaIfLaserTempLowRelativeThreshold Integer32,
oaIfLaserTempHighRelativeThreshold Integer32,
oaIfAmpTypeNotSupportedByHw FaultStatus,
oaIfWantedSignalPowerLevel Integer32,
oaIfObjectProperty ObjectProperty,
oaIfLaserForcedOn INTEGER,
oaIfActualLaserTemp Integer32,
oaIfAutomaticPowerShutdown INTEGER,
oaIfDisabled FaultStatus,
oaIfWantedPowerLimit Integer32,
oaIfModuleInfo DisplayString,
oaIfMonitorInsertionLoss DisplayString,
oaIfNumMonitorInsertionLoss Unsigned32,
oaIfFunctionalType INTEGER,
oaIfActualGain Integer32,
oaIfSaturationFault FaultStatus,
oaIfWantedGainTilt Integer32,
oaIfTxPowerLevelLowThreshold Integer32,
oaIfLaserPumpBias Unsigned32,
oaIfCaseTempOutOfrange FaultStatus,
oaIfLaserTempOutOfRange FaultStatus,
oaIfSupportsReadMonitorInsertionLoss TruthValue,
oaIfTxSignalStatus INTEGER,
oaIfRxSignalStatus INTEGER,
oaIfOutputPowerFail FaultStatus
}
oaIfIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An arbitrary index assigned to each entry.
"
::= { oaIfEntry 1 }
oaIfName OBJECT-TYPE
SYNTAX MgmtNameString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management name of the interface, for
example 'oa:1:2:1-2', where the first number
indicates sub-rack, the second slot number and
the third is the port number.
Examples:
oa:s:s:p - Optical amplifier interface
"
::= { oaIfEntry 2 }
oaIfDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User configurable label.
"
DEFVAL { "" }
::= { oaIfEntry 3 }
oaIfSubrack OBJECT-TYPE
SYNTAX SubrackNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the subrack where the interface
is located.
"
::= { oaIfEntry 4 }
oaIfSlot OBJECT-TYPE
SYNTAX SlotNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the slot where the interface is
located.
"
::= { oaIfEntry 5 }
oaIfTxPort OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the port where the TX-side of the
interface is located.
"
::= { oaIfEntry 6 }
oaIfRxPort OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the port where the RX-side of
the interface is located.
"
::= { oaIfEntry 7 }
oaIfInvPhysIndexOrZero OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The row in the invPhysTable for this interface.
Set to 0 if not known.
"
::= { oaIfEntry 8 }
oaIfAdminStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceAdminStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative state for the interface.
down - The interface should be inactive.
service - The interface is activated but alarms
are suppressed. Intended for use during service
or re-configuration. When service is concluded
adminStatus should be set to 'up' again.
up - The interface should be activated when
it becomes available. Alarms are not suppressed.
This attribute can be written via SNMP.
"
DEFVAL { up }
::= { oaIfEntry 9 }
oaIfOperStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceOperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state for the interface.
notPresent - The physical resources are not
available.
down - The interface is de-activated or the are
faults preventing it from going to the 'up'-state.
up - The interface is operational.
"
DEFVAL { notPresent }
::= { oaIfEntry 10 }
oaIfLaserStatus OBJECT-TYPE
SYNTAX INTEGER {
off (1),
on (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state of the laser.
off - The laser is turned off.
on - The laser is turned on.
"
::= { oaIfEntry 11 }
oaIfAmplifierType OBJECT-TYPE
SYNTAX INTEGER {
pre25ad (1),
pre25tm (2),
pow10 (3),
pre10ad (4),
pre10tm (5),
constantGain (6),
constantSignalPower (7),
constantPower (8),
constantGainLI (9),
constantGainHI (10) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of amplifier for this interface.
preAmp25GAd - pre-amplifier for 2.5 G,
add-drop
preAmp25GTm - pre-amplifier for 2.5 G,
terminal multiplexor
powAmp10G - power amplifier for 10 G
preAmp10GAd - pre-amplifier for 10 G,
add-drop
preAmp10GTm - pre-amplifier for 10 G,
terminal multiplexor
constantGain - used for pre-amps and other
point-to-point links. Uses ASE compensation.
=> specify wantedGain
constantGainLI - Default value. Works as constantGain
but uses low input power mode. Please,
refer to OA commissioning manual to decideoaIfRxSignalStatus
which gain mode that should be used.
constantGainHI - Works as constantGain but uses high
input power mode. Please, refer to OA
commissioning manual to decide which gain
mode that should be used.
constantSignalPower - used in combination
with 2 channel add-drop filters.
Uses ASE compensation.
=> specify wantedSignalPower
constantPower - For test purposes
No ASE compensation.
=> specify wantedAbsolutePower
"
::= { oaIfEntry 12 }
oaIfWantedAbsolutePowerLevel OBJECT-TYPE
SYNTAX Integer32 (0..195)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For powAmp10G and constantPower, the
user can give the wanted absolute power level
in units of 0.1 dBm.
For OA10 and OA17 in constantGain and
constantSignalPower, this parameter shows the
derived absolute power level. The value is
calculated from the other given parameters.
"
DEFVAL { 90 }
::= { oaIfEntry 13 }
oaIfWantedRelativePowerLevel OBJECT-TYPE
SYNTAX Integer32 (-60..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wanted offset from production setting in units
of 0.1 dBm.
Applicable for preAmp25GAd and preAmp10GAd.
Note that the output power level is dependent on
the power of the input signal, so you might not
always get the power that you want.
"
DEFVAL { 0 }
::= { oaIfEntry 14 }
oaIfWantedGain OBJECT-TYPE
SYNTAX Integer32 (130..330)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signal gain setting in units of 0.1 dB.
Applicable for preAmp25GTm, preAmp10GTm
and constantGain/LI/HI.
This attribute can be written via SNMP.
"
DEFVAL { 200 }
::= { oaIfEntry 15 }
oaIfFrequencyMin OBJECT-TYPE
SYNTAX LambdaFrequency
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Lowest amplified freqency in hundreds of
GHz (0.01 GHz).
Supported range 19210 ... 19590 (c921 .. c959)
"
DEFVAL { ch921 }
::= { oaIfEntry 16 }
oaIfFrequencyMax OBJECT-TYPE
SYNTAX LambdaFrequency
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Highest amplified freqency in hundreds of
GHz (0.01 GHz).
Supported range 19210 ... 19590 (c921 .. c959)
"
DEFVAL { ch959 }
::= { oaIfEntry 17 }
oaIfNominalTxPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The production setting for output power in
units of 0.1 dBm.
"
::= { oaIfEntry 18 }
oaIfTxPowerLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmitted power level in units of 0.1 dBm.
"
::= { oaIfEntry 19 }
oaIfRxPowerLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The received power level in units of 0.1 dBm.
"
::= { oaIfEntry 20 }
oaIfRxPowerLevelLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-50..80)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower threshold for received power level
relative to the loss of signal threshold,
in units of 0.1 dB.
"
DEFVAL { 30 }
::= { oaIfEntry 21 }
oaIfLaserBias OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measures laser bias current value in tenths of
mA (0.1 mA).
"
::= { oaIfEntry 22 }
oaIfNominalLaserTemp OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The pre-set laser temperature (0.1 deg C)
"
::= { oaIfEntry 23 }
oaIfRelativeLaserTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current offset from the pre-set temperature
in units of 0.1 degrees centigrade.
"
::= { oaIfEntry 24 }
oaIfLossOfSignalThreshold OBJECT-TYPE
SYNTAX Integer32 (-560..80)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold for loss of signal.
Note: Depending on the type of optical amplifier
the value range may vary.
"
DEFVAL { -560 }
::= { oaIfEntry 25 }
oaIfLossOfSignal OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of signal.
Applicable for all signal formats.
A(ctivation): Active loss of signal HW
indication.
D(e-activation): Inactive loss of signal HW
indication.
"
::= { oaIfEntry 26 }
oaIfPumpLaserTempHigh OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pump laser temperature too high.
A(ctivation): Temperature exceedes threshold.
D(e-activation): Temperature below threshold
again.
"
::= { oaIfEntry 27 }
oaIfRegulationProblemRxPowerHigh OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The input power is above meassuring range.
A: The received power level exceeds the
associated threshold.
D: The received power level is 0.5 dBm below
the threshold.
"
::= { oaIfEntry 28 }
oaIfRegulationProblemTxPowerHigh OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The output power is above meassuring range.
A: The received power level exceeds the
associated threshold.
D: The received power level is 0.5 dBm below
the threshold.
"
::= { oaIfEntry 29 }
oaIfRegulationProblemTxPowerLow OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The output power is below meassuring range.
A: The transmitted power level below the associated
threshold.
D: The transmitted power level is 0.5 dBm above the
threshold.
"
::= { oaIfEntry 30 }
oaIfReceivedPowerLow OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received power level low threshold exceeded.
A: The received power level is below the
associated threshold.
D: The received power level is 0.5 dBm above the
threshold.
"
::= { oaIfEntry 31 }
oaIfLaserBiasHigh OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser bias high threshold exceeded.
A: The laser bias current exceeds the associated
threshold.
D: The laser bias current is 0.5 mA below the
associated threshold.
"
::= { oaIfEntry 32 }
oaIfLaserTempControlFault OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The pump laser temperature exceeds the
associated threshold.
A: The temperature exceeds the value.
D: The temperature is below the value.
"
::= { oaIfEntry 33 }
oaIfHwMissing OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The HW for this i/f is not present
A: Wrong HW is inserted in subrack.
D: Correct HW is inserted in subrack.
"
::= { oaIfEntry 34 }
oaIfConfigurationCommand OBJECT-TYPE
SYNTAX CommandString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Select which amplifier type to use. All modes are not applicable
for all type of amplifier boards.
constantGain: Amplifier will set output power according to
the input power and the given gain
constantSignalPower: Amplifier will set a constant output power
with noise-compensation
constantPower: Amplifier will set a constant output power
independent of input power
constantGainLI: Amplifier will work with constant gain in the low
input power region (-35 to -5 dBm)
constantGainHI: Amplifier will work with constant gain in the
high input power region (-25 to +8 dBm)
pow10: Power amplifier for 10G
pre10ad: Pre-amplifier for 10G in add/drop config.
pre25ad: Pre-amplifier for 2.5G in add/drop config.
pre10tm: Pre-amplifier for 10G in TM configuration
pre25tm: Pre-amplifier for 2.5G in TM configuration
"
::= { oaIfEntry 35 }
oaIfPumpLaserTempLow OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pump laser temperature too low.
A(ctivation): Temperature exceedes threshold.
D(e-activation): Temperature above threshold
again.
"
::= { oaIfEntry 36 }
oaIfLaserTempLowRelativeThreshold OBJECT-TYPE
SYNTAX Integer32 (-100..150)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold for the Laser Temp Low alarm, expressed
as an offset from a pre-set nominal temperature,
in units of 0.1 degrees centigrade.
"
DEFVAL { -30 }
::= { oaIfEntry 37 }
oaIfLaserTempHighRelativeThreshold OBJECT-TYPE
SYNTAX Integer32 (-250..450)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold for the Laser Temp High alarm, expressed
as an offset from a pre-set nominal temperature,
in units of 0.1 degrees centigrade.
"
DEFVAL { 30 }
::= { oaIfEntry 38 }
oaIfAmpTypeNotSupportedByHw OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HW revision does not support
the selected amplifier type.
"
::= { oaIfEntry 39 }
oaIfWantedSignalPowerLevel OBJECT-TYPE
SYNTAX Integer32 (-150..-50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wanted offset from production setting in units
of 0.1 dBm.
Applicable for preAmp25GAd and preAmp10GAd.
Note that the output power level is dependent on
the power of the input signal, so you might not
always get the power that you want.
"
DEFVAL { -100 }
::= { oaIfEntry 40 }
oaIfObjectProperty OBJECT-TYPE
SYNTAX ObjectProperty
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Property mask.
"
::= { oaIfEntry 41 }
oaIfLaserForcedOn OBJECT-TYPE
SYNTAX INTEGER {
disabled (1),
enabled (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled, the laser control is on regardless of
whether there is an input signal present or not.
disabled - the laser control is activated first
after input signal is detected
enabled - the laser control is always on
"
DEFVAL { disabled }
::= { oaIfEntry 42 }
oaIfActualLaserTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current laser temperature
in units of 0.1 degrees centigrade.
"
::= { oaIfEntry 43 }
oaIfAutomaticPowerShutdown OBJECT-TYPE
SYNTAX INTEGER {
disabled (1),
enabled (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled, the laser is turned off if
the input signal to the other gain block
is lost.
disabled - the laser is NOT affected by
the other gain block.
enabled - the laser is turned off if
the input to the other gain block
is lost.
"
DEFVAL { disabled }
::= { oaIfEntry 44 }
oaIfDisabled OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface is disabled.
A: Interface disabled.
D: Interface enabled.
"
::= { oaIfEntry 45 }
oaIfWantedPowerLimit OBJECT-TYPE
SYNTAX Integer32 (-70..195)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable for constantGainLI/HI.
Sets the maximum allowed output power.
This attribute can be written via SNMP.
"
DEFVAL { 167 }
::= { oaIfEntry 46 }
oaIfModuleInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information (for example firmware and serial number) about
the module.
"
::= { oaIfEntry 47 }
oaIfMonitorInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The insertion loss for the monitor port.
When the real insertion loss is not possible
to read from unit (older HW revsions), 20
(default) dB will be shown which is the
normal value.
"
::= { oaIfEntry 48 }
oaIfNumMonitorInsertionLoss OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the same parameter as Monitor Port
Insertion Loss. The difference is that you
will not see if the value can be read from
the port or not (if not 20 dB will be shown).
"
::= { oaIfEntry 49 }
oaIfFunctionalType OBJECT-TYPE
SYNTAX INTEGER {
undefined (1),
preAmp (2),
offLinePreAmp (3),
lineAmp (4),
booster (5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The functional type of amplifier. This attribute is ONLY used
by TNM and the traffic is not affected if changed.
undefined - default
preAmp - pre-amplifier. Receiving amplifier on a
terminal node.
offLinePreAmp - offline pre-amplifier. Receiving amplifier
in a non-terminal node. Offline pre-amplifier
amplifies dropped traffic, NOT line traffic.
lineAmp - line amplifier. Amplifier situated between
the terminal nodes, which amplifies passing
line traffic and (if applicable) added
traffic.
booster - booster. The transmitting amplifier from a
terminal node.
"
DEFVAL { undefined }
::= { oaIfEntry 50 }
oaIfActualGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual measured gain in units of 0.1 dB.
"
::= { oaIfEntry 51 }
oaIfSaturationFault OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Saturation alarm threshold is passed. Actual Gain < (Wanted
Gain -1 dB). The alarm can be cleared be cleared by reducing
the wanted gain attribute.
"
::= { oaIfEntry 52 }
oaIfWantedGainTilt OBJECT-TYPE
SYNTAX Integer32 (-20..20)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Settable gain tilt for variable gain OA in units of 0.1 dB.
Positive gain tilt is defined as gain increasing wavelength.
Negative gain tilt is defined as gain decreasing wavelength.
"
DEFVAL { 0 }
::= { oaIfEntry 53 }
oaIfTxPowerLevelLowThreshold OBJECT-TYPE
SYNTAX Integer32 (0..207)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower threshold for transmitted power level
transmits to the loss of signal threshold,
in units of 0.1 dB.
"
DEFVAL { 5 }
::= { oaIfEntry 54 }
oaIfLaserPumpBias OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measures laser pump bias current in
per cent (%) of max value.
"
::= { oaIfEntry 55 }
oaIfCaseTempOutOfrange OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module has shutdown automatically because of
too high case temp (>85 degC) or too low case
temp (-40 degC).
A(ctivation): Case temperature exceedes pre-set
temp range.
D(e-activation): Case temperature within pre-set
temp range again.
"
::= { oaIfEntry 56 }
oaIfLaserTempOutOfRange OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the module has shutdown automatically because of
pump laser temp out of range (15-35 degC).
A(ctivation): Laser temperature exceedes pre-set value.
D(e-activation): Laser temperature below pre-set value
again.
"
::= { oaIfEntry 57 }
oaIfSupportsReadMonitorInsertionLoss OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value tells whether a OA interface has the ability
to read the insertion loss value for the monitor port on
an interface.
true: Insertion loss can be read for this interface
false: Insertion loss cannot be read for this interface
"
::= { oaIfEntry 58 }
oaIfTxSignalStatus OBJECT-TYPE
SYNTAX INTEGER {
down (1),
degraded (2),
up (3),
notApplicable (2147483647) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state for outgoing (TX) signal
of the interface.
down - A fault that would lead to a protection
switch has occurred.
degraded - The signal quality is impaired.
up - The signal is OK.
notApplicable (2147483647) - Attribute is not used on board.
"
::= { oaIfEntry 59 }
oaIfRxSignalStatus OBJECT-TYPE
SYNTAX INTEGER {
down (1),
degraded (2),
up (3),
notApplicable (2147483647) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state for incoming (RX) signal
of the interface.
down - A major fault has occurred
degraded - The signal quality is impaired.
up - The signal is OK.
notApplicable (2147483647) - Attribute is not used on board
"
::= { oaIfEntry 60 }
oaIfOutputPowerFail OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output power failed alarm threshold is passed. Actual Gain < (Wanted
Gain -1 dB) and Output Power < (Power Limit -1 dB).
"
::= { oaIfEntry 61 }
-- ----------------------------------------------------
-- Variable Optical Attenuator interfaces
-- ----------------------------------------------------
oaVoaIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaVoaIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface list."
::= { oaVoaIfList 1 }
oaVoaIfEntry OBJECT-TYPE
SYNTAX OaVoaIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the interface list.
"
INDEX { oaVoaIfIndex }
::= { oaVoaIfTable 1 }
OaVoaIfEntry ::=
SEQUENCE {
oaVoaIfIndex Unsigned32,
oaVoaIfName MgmtNameString,
oaVoaIfDescr DisplayString,
oaVoaIfSubrack SubrackNumber,
oaVoaIfSlot SlotNumber,
oaVoaIfTxPort PortNumber,
oaVoaIfRxPort PortNumber,
oaVoaIfInvPhysIndexOrZero Unsigned32,
oaVoaIfAdminStatus BoardOrInterfaceAdminStatus,
oaVoaIfOperStatus BoardOrInterfaceOperStatus,
oaVoaIfObjectProperty ObjectProperty,
oaVoaIfControlMode INTEGER,
oaVoaIfWantedOutputPower Integer32,
oaVoaIfCurrentOutputPower Integer32,
oaVoaIfRegulationRange Unsigned32,
oaVoaIfWantedAttenuation Unsigned32,
oaVoaIfCurrentAttenuation Unsigned32,
oaVoaIfSamplePeriod Unsigned32,
oaVoaIfOuputPowerControlFailure FaultStatus,
oaVoaIfCurrentPowerOutOfRange FaultStatus,
oaVoaIfConfigurationCommand CommandString,
oaVoaIfInInstallationMode FaultStatus }
oaVoaIfIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An arbitrary index assigned to each entry.
"
::= { oaVoaIfEntry 1 }
oaVoaIfName OBJECT-TYPE
SYNTAX MgmtNameString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management name of the interface,
for example 'voa:1:2:1'.
"
::= { oaVoaIfEntry 2 }
oaVoaIfDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User configurable label.
"
DEFVAL { "" }
::= { oaVoaIfEntry 3 }
oaVoaIfSubrack OBJECT-TYPE
SYNTAX SubrackNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the subrack where the interface
is located.
"
::= { oaVoaIfEntry 4 }
oaVoaIfSlot OBJECT-TYPE
SYNTAX SlotNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the slot where the interface is
located.
"
::= { oaVoaIfEntry 5 }
oaVoaIfTxPort OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the port where the TX part of
the interface is located.
"
::= { oaVoaIfEntry 6 }
oaVoaIfRxPort OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the port where the RX part of
the interface is located.
"
::= { oaVoaIfEntry 7 }
oaVoaIfInvPhysIndexOrZero OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The row in the invPhysTable for this interface.
Set to 0 if not known.
"
::= { oaVoaIfEntry 8 }
oaVoaIfAdminStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceAdminStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative state for the interface.
down - The interface should be inactive.
service - The interface is activated but alarms
are suppressed. Intended for use during service
or re-configuration. When service is concluded
adminStatus should be set to 'up' again.
Note that there is no difference between 'up'
and 'service', if no alarms can be rasied from
this object.
up - The interface should be activated when
it becomes available. Alarms are not suppressed.
This attribute can be written via SNMP.
"
::= { oaVoaIfEntry 9 }
oaVoaIfOperStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceOperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state for the interface.
notPresent - The interface is not available.
down - The interface is not used.
up - The interface is active.
"
DEFVAL { notPresent }
::= { oaVoaIfEntry 10 }
oaVoaIfObjectProperty OBJECT-TYPE
SYNTAX ObjectProperty
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Property mask.
"
::= { oaVoaIfEntry 11 }
oaVoaIfControlMode OBJECT-TYPE
SYNTAX INTEGER {
constPower (1),
constAttenuation (2),
constPowerAtInstallation (3) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The control mode of the VOA channel.
constPower - regulate slowly towards a given
output power.
constAttenuation - set a fix attenuation
constPowerAtInstallation -
like constPower but allow faster changes
(this mode is not released)
"
DEFVAL { constPower }
::= { oaVoaIfEntry 12 }
oaVoaIfWantedOutputPower OBJECT-TYPE
SYNTAX Integer32 (-300..170)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The wanted output power.
Applicable for constPower.
"
DEFVAL { 0 }
::= { oaVoaIfEntry 13 }
oaVoaIfCurrentOutputPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual output power.
"
::= { oaVoaIfEntry 14 }
oaVoaIfRegulationRange OBJECT-TYPE
SYNTAX Unsigned32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An offset below the wanted output power
at which the 'Current Power Out Of Range'
alarm shall be raised.
When the current output power is so
far below the wanted output power,
the regulation stops and the alarm
is raised.
Applicable for constPower.
"
DEFVAL { 40 }
::= { oaVoaIfEntry 15 }
oaVoaIfWantedAttenuation OBJECT-TYPE
SYNTAX Unsigned32 (0..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The wanted attenuation.
voa8ch: applicable for constAttenuation
voa2ch: always applicable
This attribute can be written via SNMP.
"
DEFVAL { 200 }
::= { oaVoaIfEntry 16 }
oaVoaIfCurrentAttenuation OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current attenuation.
Applicable for constPower.
"
::= { oaVoaIfEntry 17 }
oaVoaIfSamplePeriod OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The approximate period between 2
consecutive measurements of the output
power
"
::= { oaVoaIfEntry 18 }
oaVoaIfOuputPowerControlFailure OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm raised when the wanted output power
can not be obtained. That is, even if the
attenuation is reduced to zero, the wanted
power can not be obtained.
"
::= { oaVoaIfEntry 19 }
oaVoaIfCurrentPowerOutOfRange OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm raised when the current output power
is outside the 'regulation range'.
The regulation range is defined by
Wanted Output Power +/- Regulation Range
At this point, no regulation will be performed.
The operator must change the wantedOutputPower.
"
::= { oaVoaIfEntry 20 }
oaVoaIfConfigurationCommand OBJECT-TYPE
SYNTAX CommandString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Select which control mode to use:
constPower
constAttenuation
"
::= { oaVoaIfEntry 21 }
oaVoaIfInInstallationMode OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm raised when the VOA is put in the
mode constPowerAtInstallation.
"
::= { oaVoaIfEntry 22 }
-- ----------------------------------------------------
-- Variable Optical Attenuator Client interfaces
-- ----------------------------------------------------
oaVoaClientIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaVoaClientIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface list."
::= { oaVoaClientIfList 1 }
oaVoaClientIfEntry OBJECT-TYPE
SYNTAX OaVoaClientIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the interface list.
"
INDEX { oaVoaClientIfIndex }
::= { oaVoaClientIfTable 1 }
OaVoaClientIfEntry ::=
SEQUENCE {
oaVoaClientIfIndex Unsigned32,
oaVoaClientIfName MgmtNameString,
oaVoaClientIfDescr DisplayString,
oaVoaClientIfSubrack SubrackNumber,
oaVoaClientIfSlot SlotNumber,
oaVoaClientIfTxPort PortNumber,
oaVoaClientIfRxPort PortNumber,
oaVoaClientIfInvPhysIndexOrZero Unsigned32,
oaVoaClientIfAdminStatus BoardOrInterfaceAdminStatus,
oaVoaClientIfOperStatus BoardOrInterfaceOperStatus,
oaVoaClientIfObjectProperty ObjectProperty,
oaVoaClientIfControlMode INTEGER,
oaVoaClientIfWantedAttenuation Unsigned32,
oaVoaClientIfCurrentAttenuation Unsigned32,
oaVoaClientIfLambda LambdaFrequency,
oaVoaClientIfAbsoluteAttenuation Unsigned32,
oaVoaClientIfVoa2CurrentAttenuation Unsigned32,
oaVoaClientIfDecreaseAttenuation Unsigned32,
oaVoaClientIfIncreaseAttenuation Unsigned32,
oaVoaClientIfInsertionLoss Unsigned32,
oaVoaClientIfExpectedFrequency LambdaFrequency,
oaVoaClientIfSfpMissing FaultStatus,
oaVoaClientIfSfpClass DisplayString,
oaVoaClientIfSfpTransmitterFailed FaultStatus,
oaVoaClientIfSfpMediaMismatch FaultStatus,
oaVoaClientIfLossOfSignal FaultStatus,
oaVoaClientIfSfpCodeMismatch FaultStatus,
oaVoaClientIfAttenuationConfigMismatch FaultStatus }
oaVoaClientIfIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An arbitrary index assigned to each entry.
"
::= { oaVoaClientIfEntry 1 }
oaVoaClientIfName OBJECT-TYPE
SYNTAX MgmtNameString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management name of the interface,
for example 'voaClient:1:2:1' which
indicates subrack 1, board 2 and port 1.
"
::= { oaVoaClientIfEntry 2 }
oaVoaClientIfDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User configurable label.
"
DEFVAL { "" }
::= { oaVoaClientIfEntry 3 }
oaVoaClientIfSubrack OBJECT-TYPE
SYNTAX SubrackNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the subrack where the interface
is located.
"
::= { oaVoaClientIfEntry 4 }
oaVoaClientIfSlot OBJECT-TYPE
SYNTAX SlotNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the slot where the interface is
located.
"
::= { oaVoaClientIfEntry 5 }
oaVoaClientIfTxPort OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the port where the Tx part of
the interface is located.
"
::= { oaVoaClientIfEntry 6 }
oaVoaClientIfRxPort OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the port where the Rx part of
the interface is located.
"
::= { oaVoaClientIfEntry 7 }
oaVoaClientIfInvPhysIndexOrZero OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The row in the invPhysTable for this interface.
Set to 0 if not known.
"
::= { oaVoaClientIfEntry 8 }
oaVoaClientIfAdminStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceAdminStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative state for the interface.
down - The interface should be inactive.
service - The interface is activated but alarms
are suppressed. Intended for use during service
or re-configuration. When service is concluded
adminStatus should be set to 'up' again.
up - The interface should be activated when
it becomes available. Alarms are not suppressed.
"
DEFVAL { up }
::= { oaVoaClientIfEntry 9 }
oaVoaClientIfOperStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceOperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state for the interface.
notPresent - The interface is not available.
down - The interface is not used.
up - The interface is active.
"
DEFVAL { notPresent }
::= { oaVoaClientIfEntry 10 }
oaVoaClientIfObjectProperty OBJECT-TYPE
SYNTAX ObjectProperty
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Property mask.
"
::= { oaVoaClientIfEntry 11 }
oaVoaClientIfControlMode OBJECT-TYPE
SYNTAX INTEGER {
constAttenuation (1) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The control mode of the VOA channel.
constAttenuation - set a fix attenuation
"
DEFVAL { constAttenuation }
::= { oaVoaClientIfEntry 12 }
oaVoaClientIfWantedAttenuation OBJECT-TYPE
SYNTAX Unsigned32 (0..200|2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The wanted attenuation.
Applicable for constAttenuation
This attribute can be written via SNMP if not set to 2147483647.
"
DEFVAL { 200 }
::= { oaVoaClientIfEntry 13 }
oaVoaClientIfCurrentAttenuation OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current attenuation.
Applicable in case of MDU40 boards.
"
::= { oaVoaClientIfEntry 14 }
oaVoaClientIfLambda OBJECT-TYPE
SYNTAX LambdaFrequency
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The frequency given in hundreds of GHz
(0.01 GHz). Set to 0 for transparent ports.
"
::= { oaVoaClientIfEntry 15 }
oaVoaClientIfAbsoluteAttenuation OBJECT-TYPE
SYNTAX Unsigned32 (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The wanted absolute attenuation including
the insertion loss. This value can never be
set below the upper limit of the insertion loss.
VOA8CHSFP: The range is dependent on the
inserted VOA SFP.
This attribute can be written via SNMP.
"
DEFVAL { 200 }
::= { oaVoaClientIfEntry 16 }
oaVoaClientIfVoa2CurrentAttenuation OBJECT-TYPE
SYNTAX Unsigned32 (0..300)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value shows the current set absolute attenua-
tion on VOA8ch-II and voa8chsfp. This value is
usually the same value as the absolute attenuation
except when a decrase or increase of attenuation is
ongoing or when administrative status is set to down.
"
DEFVAL { 200 }
::= { oaVoaClientIfEntry 17 }
oaVoaClientIfDecreaseAttenuation OBJECT-TYPE
SYNTAX Unsigned32 (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The wanted decrease of the current attenuation.
This attribute can be written via SNMP.
"
DEFVAL { 0 }
::= { oaVoaClientIfEntry 18 }
oaVoaClientIfIncreaseAttenuation OBJECT-TYPE
SYNTAX Unsigned32 (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The wanted increase of the current attenuation.
This attribute can be written via SNMP.
"
DEFVAL { 0 }
::= { oaVoaClientIfEntry 19 }
oaVoaClientIfInsertionLoss OBJECT-TYPE
SYNTAX Unsigned32 (0..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The insertion loss for the port. The attenuation
can never be set to a value below this value.
"
DEFVAL { 25 }
::= { oaVoaClientIfEntry 20 }
oaVoaClientIfExpectedFrequency OBJECT-TYPE
SYNTAX LambdaFrequency
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The frequency given in hundreds of GHz
(0.01 GHz). This value is only used for
presentation purposes in name of port.
"
DEFVAL { 0 }
::= { oaVoaClientIfEntry 21 }
oaVoaClientIfSfpMissing OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An expected VOA SFP is missing.
A(ctivation): An expected SFP is missing.
D(e-activation): The missing SFP is inserted.
"
::= { oaVoaClientIfEntry 22 }
oaVoaClientIfSfpClass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"String that contains general information about
the SFP.
"
DEFVAL { "" }
::= { oaVoaClientIfEntry 23 }
oaVoaClientIfSfpTransmitterFailed OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SFP has detected a failure
in the transmitter part.
A(ctivation): The transmitter has failed
D(e-activation): The transmitter is OK again
"
::= { oaVoaClientIfEntry 24 }
oaVoaClientIfSfpMediaMismatch OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the inserted SFP is not the expected one.
A(ctivation): Invalid or mismatching SFP media is
detected.
D(e-activation): The correct SFP is used.
"
::= { oaVoaClientIfEntry 25 }
oaVoaClientIfLossOfSignal OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of signal.
A(ctivation): Active loss of signal HW
indication.
D(e-activation): Inactive loss of signal HW
indication.
"
::= { oaVoaClientIfEntry 26 }
oaVoaClientIfSfpCodeMismatch OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The inserted SFP does not have a legal
manufacturer code.
A(ctivation): A SFP with illegal code is inserted.
D(e-activation): The SFP with illegal code is removed.
"
::= { oaVoaClientIfEntry 27 }
oaVoaClientIfAttenuationConfigMismatch OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wanted attenuation is not supported by the
inserted SFP.
"
::= { oaVoaClientIfEntry 28 }
-- ----------------------------------------------------
-- Variable Optical Attenuator Line interfaces
-- ----------------------------------------------------
oaVoaLineIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaVoaLineIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface list."
::= { oaVoaLineIfList 1 }
oaVoaLineIfEntry OBJECT-TYPE
SYNTAX OaVoaLineIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the interface list.
"
INDEX { oaVoaLineIfIndex }
::= { oaVoaLineIfTable 1 }
OaVoaLineIfEntry ::=
SEQUENCE {
oaVoaLineIfIndex Unsigned32,
oaVoaLineIfName MgmtNameString,
oaVoaLineIfDescr DisplayString,
oaVoaLineIfSubrack SubrackNumber,
oaVoaLineIfSlot SlotNumber,
oaVoaLineIfTxPort PortNumber,
oaVoaLineIfRxPort PortNumber,
oaVoaLineIfInvPhysIndexOrZero Unsigned32,
oaVoaLineIfAdminStatus BoardOrInterfaceAdminStatus,
oaVoaLineIfOperStatus BoardOrInterfaceOperStatus,
oaVoaLineIfModuleFailure FaultStatus,
oaVoaLineIfObjectProperty ObjectProperty }
oaVoaLineIfIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An arbitrary index assigned to each entry.
"
::= { oaVoaLineIfEntry 1 }
oaVoaLineIfName OBJECT-TYPE
SYNTAX MgmtNameString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management name of the interface, for
example 'VoaLine:1:2:1-2', where the first number
indicates sub-rack, the second slot number and
the third is the port number.
Examples:
oaVoaLine:s:s:p - line interface
"
::= { oaVoaLineIfEntry 2 }
oaVoaLineIfDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User configurable label.
This attribute can be written via SNMP.
"
DEFVAL { "" }
::= { oaVoaLineIfEntry 3 }
oaVoaLineIfSubrack OBJECT-TYPE
SYNTAX SubrackNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the subrack where the interface
is located.
"
::= { oaVoaLineIfEntry 4 }
oaVoaLineIfSlot OBJECT-TYPE
SYNTAX SlotNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the slot where the interface is
located.
"
::= { oaVoaLineIfEntry 5 }
oaVoaLineIfTxPort OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the port where the TX-side of the
interface is located.
"
::= { oaVoaLineIfEntry 6 }
oaVoaLineIfRxPort OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of the port where the RX-side of
the interface is located.
"
::= { oaVoaLineIfEntry 7 }
oaVoaLineIfInvPhysIndexOrZero OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The row in the invPhysTable for this interface.
Set to 0 if not known.
"
::= { oaVoaLineIfEntry 8 }
oaVoaLineIfAdminStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceAdminStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative state for the interface.
down - The interface should be inactive.
service - The interface is activated but alarms
are suppressed. Intended for use during service
or re-configuration. When service is concluded
adminStatus should be set to 'up' again.
up - The interface should be activated when
it becomes available. Alarms are not suppressed.
"
DEFVAL { up }
::= { oaVoaLineIfEntry 9 }
oaVoaLineIfOperStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceOperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state for the interface.
notPresent - The interface is not available.
down - The interface is not used.
up - The interface is active.
"
DEFVAL { notPresent }
::= { oaVoaLineIfEntry 10 }
oaVoaLineIfModuleFailure OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module HW has detected a failure.
A: The module has failed
D: The module is OK again
"
::= { oaVoaLineIfEntry 11 }
oaVoaLineIfObjectProperty OBJECT-TYPE
SYNTAX ObjectProperty
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Property mask.
"
::= { oaVoaLineIfEntry 12 }
-- ----------------------------------------------------
-- Optical Module information
-- ----------------------------------------------------
oaModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The module list."
::= { oaModuleList 1 }
oaModuleEntry OBJECT-TYPE
SYNTAX OaModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the module list.
"
INDEX { oaModuleIndex }
::= { oaModuleTable 1 }
OaModuleEntry ::=
SEQUENCE {
oaModuleIndex Unsigned32,
oaModuleName MgmtNameString,
oaModuleDescr DisplayString,
oaModuleSubrack SubrackNumber,
oaModuleSlot SlotNumber,
oaModuleNumber PortNumber,
oaModuleInvPhysIndexOrZero Unsigned32,
oaModuleAdminStatus BoardOrInterfaceAdminStatus,
oaModuleOperStatus BoardOrInterfaceOperStatus,
oaModuleObjectProperty ObjectProperty,
oaModuleNominalTemp Integer32,
oaModuleRelativeTemp Integer32,
oaModuleTempFailure FaultStatus,
oaModuleTemperature Integer32,
oaModuleCommunicationFailure FaultStatus,
oaModuleModuleInfo DisplayString,
oaModuleVcomThresholdExceeded FaultStatus,
oaModuleFirmwareUpgradeAvailable FaultStatus,
oaModuleWarmingUp FaultStatus,
oaModuleFailure FaultStatus}
oaModuleIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An arbitrary index assigned to each entry.
"
::= { oaModuleEntry 1 }
oaModuleName OBJECT-TYPE
SYNTAX MgmtNameString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management name of the interface,
for example 'module:1:2:1'.
"
::= { oaModuleEntry 2 }
oaModuleDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User configurable label.
"
DEFVAL { "" }
::= { oaModuleEntry 3 }
oaModuleSubrack OBJECT-TYPE
SYNTAX SubrackNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the subrack where the module
is located.
"
::= { oaModuleEntry 4 }
oaModuleSlot OBJECT-TYPE
SYNTAX SlotNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the slot where the module is
located.
"
::= { oaModuleEntry 5 }
oaModuleNumber OBJECT-TYPE
SYNTAX PortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the module on the board.
"
::= { oaModuleEntry 6 }
oaModuleInvPhysIndexOrZero OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The row in the invPhysTable for this interface.
Set to 0 if not known.
"
::= { oaModuleEntry 7 }
oaModuleAdminStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceAdminStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative state for the module.
up - Alarms are not suppressed.
service - Alarms from the module are suppressed.
The module is still activated.
down - Currently not used.
"
DEFVAL { up }
::= { oaModuleEntry 8 }
oaModuleOperStatus OBJECT-TYPE
SYNTAX BoardOrInterfaceOperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state for the module.
notPresent - The module is not available.
down - The module is not used.
up - The module is active.
"
DEFVAL { notPresent }
::= { oaModuleEntry 9 }
oaModuleObjectProperty OBJECT-TYPE
SYNTAX ObjectProperty
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Property mask.
"
::= { oaModuleEntry 10 }
oaModuleNominalTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The set temperature in units of 0.1 degrees centigrade.
"
::= { oaModuleEntry 11 }
oaModuleRelativeTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The relative temperature in units of 0.1 degrees centigrade.
"
::= { oaModuleEntry 12 }
oaModuleTempFailure OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module temperature is above/below expected one.
A: The temperature is not correct.
D: The temperature becomes correct.
"
::= { oaModuleEntry 13 }
oaModuleTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature of the module in 0.1 degrees
centigrade
"
::= { oaModuleEntry 14 }
oaModuleCommunicationFailure OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The communication with the module failed.
A(ctivation): Failed to talk to the module
D(e-activation): Could talk to the module again
"
::= { oaModuleEntry 15 }
oaModuleModuleInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information (for example firmware and serial number) about the module.
"
::= { oaModuleEntry 16 }
oaModuleVcomThresholdExceeded OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The common voltage supply in the ROADM module has exceeded
recommended threshold. Firmware upgrade is recommended to resolve this alarm.
A(ctivation): The VCOM threshold is exceeded
D(e-activation): The VCOM threshold is OK again
"
::= { oaModuleEntry 17 }
oaModuleFirmwareUpgradeAvailable OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An upgrade is available for the ROADM module. See release
notes for details on how to obtain and install the upgrade
"
::= { oaModuleEntry 18 }
oaModuleWarmingUp OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ROADM module is warming up, the optics has not reached a stable
temperature, all channels are blocked.
A(ctivation): cold start of ROADM board
D(e-activation): the warning is cleared as soon as the module
has reached a stable temperature, this takes 3-8 minutes
"
::= { oaModuleEntry 19 }
oaModuleFailure OBJECT-TYPE
SYNTAX FaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module HW has detected a failure.
A(ctivation): The module has failed
D(e-activation): The module is OK again
"
::= { oaModuleEntry 20 }
-- ----------------------------------------------------
-- Notifications
-- ----------------------------------------------------
-- n/a
-- ----------------------------------------------------
-- Object and event groups
-- ----------------------------------------------------
oaGeneralGroup OBJECT-GROUP
OBJECTS {
oaGeneralLastChangeTime,
oaGeneralStateLastChangeTime}
STATUS deprecated
DESCRIPTION
"The general objects."
::= { lumOaGroups 1 }
oaIfGroup OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfHwMissing }
STATUS deprecated
DESCRIPTION
"The oa interface objects."
::= { lumOaGroups 2 }
oaIfGroupV2 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault }
STATUS deprecated
DESCRIPTION
"The oa interface objects."
::= { lumOaGroups 3 }
oaIfGroupV3 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold }
STATUS deprecated
DESCRIPTION
"The oa interface objects."
::= { lumOaGroups 4 }
oaGeneralGroupV2 OBJECT-GROUP
OBJECTS {
oaGeneralLastChangeTime,
oaGeneralStateLastChangeTime,
oaGeneralOaIfTableSize }
STATUS current
DESCRIPTION
"The general objects. (3.1)"
::= { lumOaGroups 5 }
oaIfGroupV4 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel }
STATUS deprecated
DESCRIPTION
"The oa interface objects. (3.2)"
::= { lumOaGroups 6 }
oaIfGroupV5 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel,
oaIfObjectProperty,
oaIfLaserForcedOn,
oaIfActualLaserTemp,
oaIfAutomaticPowerShutdown }
STATUS current
DESCRIPTION
"The oa interface objects. (4.0)"
::= { lumOaGroups 7 }
oaIfGroupV6 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel,
oaIfObjectProperty,
oaIfLaserForcedOn,
oaIfActualLaserTemp,
oaIfAutomaticPowerShutdown,
oaIfDisabled }
STATUS deprecated
DESCRIPTION
"The oa interface objects. (5.0)"
::= { lumOaGroups 8 }
oaVoaIfGroupV1 OBJECT-GROUP
OBJECTS {
oaVoaIfIndex,
oaVoaIfName,
oaVoaIfDescr,
oaVoaIfSubrack,
oaVoaIfSlot,
oaVoaIfTxPort,
oaVoaIfRxPort,
oaVoaIfInvPhysIndexOrZero,
oaVoaIfAdminStatus,
oaVoaIfOperStatus,
oaVoaIfObjectProperty,
oaVoaIfControlMode,
oaVoaIfWantedOutputPower,
oaVoaIfCurrentOutputPower,
oaVoaIfRegulationRange,
oaVoaIfWantedAttenuation,
oaVoaIfCurrentAttenuation,
oaVoaIfSamplePeriod,
oaVoaIfOuputPowerControlFailure,
oaVoaIfCurrentPowerOutOfRange,
oaVoaIfConfigurationCommand,
oaVoaIfInInstallationMode
}
STATUS current
DESCRIPTION
"The voa interface objects. (5.0)"
::= { lumOaGroups 9 }
oaIfGroupV7 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel,
oaIfObjectProperty,
oaIfLaserForcedOn,
oaIfActualLaserTemp,
oaIfAutomaticPowerShutdown,
oaIfDisabled,
oaIfWantedPowerLimit }
STATUS deprecated
DESCRIPTION
"The oa interface objects. (6.0)"
::= { lumOaGroups 10 }
oaIfGroupV8 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel,
oaIfObjectProperty,
oaIfLaserForcedOn,
oaIfActualLaserTemp,
oaIfAutomaticPowerShutdown,
oaIfDisabled,
oaIfWantedPowerLimit,
oaIfModuleInfo }
STATUS deprecated
DESCRIPTION
"The oa interface objects. (10.0)"
::= { lumOaGroups 11 }
oaVoaClientIfGroupV1 OBJECT-GROUP
OBJECTS {
oaVoaClientIfIndex,
oaVoaClientIfName,
oaVoaClientIfDescr,
oaVoaClientIfSubrack,
oaVoaClientIfSlot,
oaVoaClientIfTxPort,
oaVoaClientIfRxPort,
oaVoaClientIfInvPhysIndexOrZero,
oaVoaClientIfAdminStatus,
oaVoaClientIfOperStatus,
oaVoaClientIfObjectProperty,
oaVoaClientIfControlMode,
oaVoaClientIfWantedAttenuation,
oaVoaClientIfCurrentAttenuation,
oaVoaClientIfLambda
}
STATUS deprecated
DESCRIPTION
"The voa client interface objects. (10.0)"
::= { lumOaGroups 12 }
oaVoaLineIfGroupV1 OBJECT-GROUP
OBJECTS {
oaVoaLineIfIndex,
oaVoaLineIfName,
oaVoaLineIfDescr,
oaVoaLineIfSubrack,
oaVoaLineIfSlot,
oaVoaLineIfTxPort,
oaVoaLineIfRxPort,
oaVoaLineIfInvPhysIndexOrZero,
oaVoaLineIfAdminStatus,
oaVoaLineIfOperStatus,
oaVoaLineIfModuleFailure,
oaVoaLineIfObjectProperty
}
STATUS current
DESCRIPTION
"The voa line interface objects. (10.0)"
::= { lumOaGroups 13 }
oaGeneralGroupV3 OBJECT-GROUP
OBJECTS {
oaGeneralLastChangeTime,
oaGeneralStateLastChangeTime,
oaGeneralOaIfTableSize,
oaGeneralVoaIfTableSize,
oaGeneralVoaClientIfTableSize,
oaGeneralVoaLineIfTableSize }
STATUS deprecated
DESCRIPTION
"The general objects. (10.0)"
::= { lumOaGroups 14 }
oaVoaClientIfGroupV2 OBJECT-GROUP
OBJECTS {
oaVoaClientIfIndex,
oaVoaClientIfName,
oaVoaClientIfDescr,
oaVoaClientIfSubrack,
oaVoaClientIfSlot,
oaVoaClientIfTxPort,
oaVoaClientIfRxPort,
oaVoaClientIfInvPhysIndexOrZero,
oaVoaClientIfAdminStatus,
oaVoaClientIfOperStatus,
oaVoaClientIfObjectProperty,
oaVoaClientIfControlMode,
oaVoaClientIfWantedAttenuation,
oaVoaClientIfCurrentAttenuation,
oaVoaClientIfLambda,
oaVoaClientIfAbsoluteAttenuation,
oaVoaClientIfVoa2CurrentAttenuation,
oaVoaClientIfDecreaseAttenuation,
oaVoaClientIfIncreaseAttenuation,
oaVoaClientIfInsertionLoss,
oaVoaClientIfExpectedFrequency
}
STATUS deprecated
DESCRIPTION
"The voa client interface objects. (11.0)"
::= { lumOaGroups 15 }
oaModuleGroupV1 OBJECT-GROUP
OBJECTS {
oaModuleIndex,
oaModuleName,
oaModuleDescr,
oaModuleSubrack,
oaModuleSlot,
oaModuleNumber,
oaModuleInvPhysIndexOrZero,
oaModuleAdminStatus,
oaModuleOperStatus,
oaModuleObjectProperty,
oaModuleNominalTemp,
oaModuleRelativeTemp,
oaModuleTempFailure
}
STATUS deprecated
DESCRIPTION
"The module objects. (11.0)"
::= { lumOaGroups 16 }
oaGeneralGroupV4 OBJECT-GROUP
OBJECTS {
oaGeneralLastChangeTime,
oaGeneralStateLastChangeTime,
oaGeneralOaIfTableSize,
oaGeneralVoaIfTableSize,
oaGeneralVoaClientIfTableSize,
oaGeneralVoaLineIfTableSize,
oaGeneralOaModuleTableSize
}
STATUS current
DESCRIPTION
"The general objects. (11.0)"
::= { lumOaGroups 17 }
oaIfGroupV9 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel,
oaIfObjectProperty,
oaIfLaserForcedOn,
oaIfActualLaserTemp,
oaIfAutomaticPowerShutdown,
oaIfDisabled,
oaIfWantedPowerLimit,
oaIfModuleInfo,
oaIfMonitorInsertionLoss,
oaIfNumMonitorInsertionLoss,
oaIfFunctionalType }
STATUS deprecated
DESCRIPTION
"The oa interface objects. (11.0)"
::= { lumOaGroups 18 }
oaModuleGroupV2 OBJECT-GROUP
OBJECTS {
oaModuleIndex,
oaModuleName,
oaModuleDescr,
oaModuleSubrack,
oaModuleSlot,
oaModuleNumber,
oaModuleInvPhysIndexOrZero,
oaModuleAdminStatus,
oaModuleOperStatus,
oaModuleObjectProperty,
oaModuleNominalTemp,
oaModuleRelativeTemp,
oaModuleTempFailure,
oaModuleTemperature,
oaModuleCommunicationFailure,
oaModuleModuleInfo
}
STATUS deprecated
DESCRIPTION
"The module objects. (12.0)"
::= { lumOaGroups 19 }
oaModuleGroupV3 OBJECT-GROUP
OBJECTS {
oaModuleIndex,
oaModuleName,
oaModuleDescr,
oaModuleSubrack,
oaModuleSlot,
oaModuleNumber,
oaModuleInvPhysIndexOrZero,
oaModuleAdminStatus,
oaModuleOperStatus,
oaModuleObjectProperty,
oaModuleNominalTemp,
oaModuleRelativeTemp,
oaModuleTempFailure,
oaModuleTemperature,
oaModuleCommunicationFailure,
oaModuleModuleInfo,
oaModuleVcomThresholdExceeded,
oaModuleFirmwareUpgradeAvailable
}
STATUS deprecated
DESCRIPTION
"The module objects. (23.0)"
::= { lumOaGroups 24 }
oaIfGroupV10 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel,
oaIfObjectProperty,
oaIfLaserForcedOn,
oaIfActualLaserTemp,
oaIfAutomaticPowerShutdown,
oaIfDisabled,
oaIfWantedPowerLimit,
oaIfModuleInfo,
oaIfMonitorInsertionLoss,
oaIfNumMonitorInsertionLoss,
oaIfFunctionalType,
oaIfActualGain,
oaIfSaturationFault }
STATUS deprecated
DESCRIPTION
"The oa interface objects. (15.0)"
::= { lumOaGroups 20 }
oaIfGroupV11 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel,
oaIfObjectProperty,
oaIfLaserForcedOn,
oaIfActualLaserTemp,
oaIfAutomaticPowerShutdown,
oaIfDisabled,
oaIfWantedPowerLimit,
oaIfModuleInfo,
oaIfMonitorInsertionLoss,
oaIfNumMonitorInsertionLoss,
oaIfFunctionalType,
oaIfActualGain,
oaIfSaturationFault,
oaIfWantedGainTilt
}
STATUS deprecated
DESCRIPTION
"The oa interface objects. (17.0)"
::= { lumOaGroups 21 }
oaVoaClientIfGroupV3 OBJECT-GROUP
OBJECTS {
oaVoaClientIfIndex,
oaVoaClientIfName,
oaVoaClientIfDescr,
oaVoaClientIfSubrack,
oaVoaClientIfSlot,
oaVoaClientIfTxPort,
oaVoaClientIfRxPort,
oaVoaClientIfInvPhysIndexOrZero,
oaVoaClientIfAdminStatus,
oaVoaClientIfOperStatus,
oaVoaClientIfObjectProperty,
oaVoaClientIfControlMode,
oaVoaClientIfWantedAttenuation,
oaVoaClientIfCurrentAttenuation,
oaVoaClientIfLambda,
oaVoaClientIfAbsoluteAttenuation,
oaVoaClientIfVoa2CurrentAttenuation,
oaVoaClientIfDecreaseAttenuation,
oaVoaClientIfIncreaseAttenuation,
oaVoaClientIfInsertionLoss,
oaVoaClientIfExpectedFrequency,
oaVoaClientIfSfpMissing,
oaVoaClientIfSfpClass,
oaVoaClientIfSfpTransmitterFailed,
oaVoaClientIfSfpMediaMismatch,
oaVoaClientIfLossOfSignal,
oaVoaClientIfSfpCodeMismatch,
oaVoaClientIfAttenuationConfigMismatch
}
STATUS current
DESCRIPTION
"The voa client interface objects. (19.0)"
::= { lumOaGroups 22 }
oaIfGroupV12 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel,
oaIfObjectProperty,
oaIfLaserForcedOn,
oaIfActualLaserTemp,
oaIfAutomaticPowerShutdown,
oaIfDisabled,
oaIfWantedPowerLimit,
oaIfModuleInfo,
oaIfMonitorInsertionLoss,
oaIfNumMonitorInsertionLoss,
oaIfFunctionalType,
oaIfActualGain,
oaIfSaturationFault,
oaIfWantedGainTilt,
oaIfTxPowerLevelLowThreshold,
oaIfLaserPumpBias,
oaIfCaseTempOutOfrange,
oaIfLaserTempOutOfRange
}
STATUS deprecated
DESCRIPTION
"The oa interface objects. (20.0)"
::= { lumOaGroups 23 }
oaIfGroupV13 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel,
oaIfObjectProperty,
oaIfLaserForcedOn,
oaIfActualLaserTemp,
oaIfAutomaticPowerShutdown,
oaIfDisabled,
oaIfWantedPowerLimit,
oaIfModuleInfo,
oaIfMonitorInsertionLoss,
oaIfNumMonitorInsertionLoss,
oaIfFunctionalType,
oaIfActualGain,
oaIfSaturationFault,
oaIfWantedGainTilt,
oaIfTxPowerLevelLowThreshold,
oaIfLaserPumpBias,
oaIfCaseTempOutOfrange,
oaIfLaserTempOutOfRange,
oaIfSupportsReadMonitorInsertionLoss
}
STATUS deprecated
DESCRIPTION
"The oa interface objects. (23.0)"
::= { lumOaGroups 25 }
oaIfGroupV14 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel,
oaIfObjectProperty,
oaIfLaserForcedOn,
oaIfActualLaserTemp,
oaIfAutomaticPowerShutdown,
oaIfDisabled,
oaIfWantedPowerLimit,
oaIfModuleInfo,
oaIfMonitorInsertionLoss,
oaIfNumMonitorInsertionLoss,
oaIfFunctionalType,
oaIfActualGain,
oaIfSaturationFault,
oaIfWantedGainTilt,
oaIfTxPowerLevelLowThreshold,
oaIfLaserPumpBias,
oaIfCaseTempOutOfrange,
oaIfLaserTempOutOfRange,
oaIfSupportsReadMonitorInsertionLoss,
oaIfTxSignalStatus,
oaIfRxSignalStatus
}
STATUS current
DESCRIPTION
"The oa interface objects. (24.0)"
::= { lumOaGroups 26 }
oaIfGroupV15 OBJECT-GROUP
OBJECTS {
oaIfIndex,
oaIfName,
oaIfDescr,
oaIfSubrack,
oaIfSlot,
oaIfTxPort,
oaIfRxPort,
oaIfInvPhysIndexOrZero,
oaIfAdminStatus,
oaIfOperStatus,
oaIfLaserStatus,
oaIfAmplifierType,
oaIfWantedAbsolutePowerLevel,
oaIfWantedRelativePowerLevel,
oaIfWantedGain,
oaIfFrequencyMin,
oaIfFrequencyMax,
oaIfNominalTxPower,
oaIfTxPowerLevel,
oaIfRxPowerLevel,
oaIfRxPowerLevelLowThreshold,
oaIfLaserBias,
oaIfNominalLaserTemp,
oaIfRelativeLaserTemp,
oaIfLossOfSignalThreshold,
oaIfLossOfSignal,
oaIfPumpLaserTempHigh,
oaIfRegulationProblemRxPowerHigh,
oaIfRegulationProblemTxPowerHigh,
oaIfRegulationProblemTxPowerLow,
oaIfReceivedPowerLow,
oaIfLaserBiasHigh,
oaIfLaserTempControlFault,
oaIfConfigurationCommand,
oaIfPumpLaserTempLow,
oaIfLaserTempLowRelativeThreshold,
oaIfLaserTempHighRelativeThreshold,
oaIfAmpTypeNotSupportedByHw,
oaIfWantedSignalPowerLevel,
oaIfObjectProperty,
oaIfLaserForcedOn,
oaIfActualLaserTemp,
oaIfAutomaticPowerShutdown,
oaIfDisabled,
oaIfWantedPowerLimit,
oaIfModuleInfo,
oaIfMonitorInsertionLoss,
oaIfNumMonitorInsertionLoss,
oaIfFunctionalType,
oaIfActualGain,
oaIfSaturationFault,
oaIfWantedGainTilt,
oaIfTxPowerLevelLowThreshold,
oaIfLaserPumpBias,
oaIfCaseTempOutOfrange,
oaIfLaserTempOutOfRange,
oaIfSupportsReadMonitorInsertionLoss,
oaIfTxSignalStatus,
oaIfRxSignalStatus,
oaIfOutputPowerFail
}
STATUS current
DESCRIPTION
"The oa interface objects. (27.0)"
::= { lumOaGroups 27 }
oaModuleGroupV4 OBJECT-GROUP
OBJECTS {
oaModuleIndex,
oaModuleName,
oaModuleDescr,
oaModuleSubrack,
oaModuleSlot,
oaModuleNumber,
oaModuleInvPhysIndexOrZero,
oaModuleAdminStatus,
oaModuleOperStatus,
oaModuleObjectProperty,
oaModuleNominalTemp,
oaModuleRelativeTemp,
oaModuleTempFailure,
oaModuleTemperature,
oaModuleCommunicationFailure,
oaModuleModuleInfo,
oaModuleFirmwareUpgradeAvailable,
oaModuleWarmingUp,
oaModuleFailure
}
STATUS current
DESCRIPTION
"The module objects. (28.0)"
::= { lumOaGroups 28 }
-- ----------------------------------------------------
-- Compliance
-- ----------------------------------------------------
lumOaBasicComplV1 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V1."
MODULE
MANDATORY-GROUPS {
oaGeneralGroup,
oaIfGroup}
::= { lumOaCompl 1 }
lumOaBasicComplV2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V2."
MODULE
MANDATORY-GROUPS {
oaGeneralGroup,
oaIfGroupV2 }
::= { lumOaCompl 2 }
lumOaBasicComplV3 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V3."
MODULE
MANDATORY-GROUPS {
oaGeneralGroup,
oaIfGroupV3 }
::= { lumOaCompl 3 }
lumOaBasicComplV4 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V4 (3.1)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV2,
oaIfGroupV3 }
::= { lumOaCompl 4 }
lumOaBasicComplV5 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V5 (3.2)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV2,
oaIfGroupV4 }
::= { lumOaCompl 5 }
lumOaBasicComplV6 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V6 (4.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV2,
oaIfGroupV5 }
::= { lumOaCompl 6 }
lumOaBasicComplV7 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V7 (5.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV2,
oaIfGroupV6,
oaVoaIfGroupV1 }
::= { lumOaCompl 7 }
lumOaBasicComplV8 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V8 (6.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV2,
oaIfGroupV7,
oaVoaIfGroupV1 }
::= { lumOaCompl 8 }
lumOaBasicComplV9 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V9 (10.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV3,
oaIfGroupV8,
oaVoaIfGroupV1,
oaVoaClientIfGroupV1,
oaVoaLineIfGroupV1 }
::= { lumOaCompl 9 }
lumOaBasicComplV10 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V10 (11.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV4,
oaIfGroupV9,
oaVoaIfGroupV1,
oaVoaClientIfGroupV2,
oaVoaLineIfGroupV1,
oaModuleGroupV1 }
::= { lumOaCompl 10 }
lumOaBasicComplV11 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V11 (12.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV4,
oaIfGroupV9,
oaVoaIfGroupV1,
oaVoaClientIfGroupV2,
oaVoaLineIfGroupV1,
oaModuleGroupV2 }
::= { lumOaCompl 11 }
lumOaBasicComplV12 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V12 (15.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV4,
oaIfGroupV10,
oaVoaIfGroupV1,
oaVoaClientIfGroupV2,
oaVoaLineIfGroupV1,
oaModuleGroupV2 }
::= { lumOaCompl 12 }
lumOaBasicComplV13 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V13 (17.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV4,
oaIfGroupV11,
oaVoaIfGroupV1,
oaVoaClientIfGroupV2,
oaVoaLineIfGroupV1,
oaModuleGroupV2 }
::= { lumOaCompl 13 }
lumOaBasicComplV14 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V14 (19.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV4,
oaIfGroupV11,
oaVoaIfGroupV1,
oaVoaClientIfGroupV3,
oaVoaLineIfGroupV1,
oaModuleGroupV2 }
::= { lumOaCompl 14 }
lumOaBasicComplV15 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V14 (20.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV4,
oaIfGroupV12,
oaVoaIfGroupV1,
oaVoaClientIfGroupV3,
oaVoaLineIfGroupV1,
oaModuleGroupV2 }
::= { lumOaCompl 15 }
lumOaBasicComplV16 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V16 (23.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV4,
oaIfGroupV13,
oaVoaIfGroupV1,
oaVoaClientIfGroupV3,
oaVoaLineIfGroupV1,
oaModuleGroupV3 }
::= { lumOaCompl 16 }
lumOaBasicComplV17 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V16 (24.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV4,
oaIfGroupV14,
oaVoaIfGroupV1,
oaVoaClientIfGroupV3,
oaVoaLineIfGroupV1,
oaModuleGroupV3 }
::= { lumOaCompl 17 }
lumOaBasicComplV18 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Basic implementation requirements for the OA MIB V16 (27.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV4,
oaIfGroupV15,
oaVoaIfGroupV1,
oaVoaClientIfGroupV3,
oaVoaLineIfGroupV1,
oaModuleGroupV3 }
::= { lumOaCompl 18 }
lumOaBasicComplV19 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Basic implementation requirements for the OA MIB V17 (28.0)."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV4,
oaIfGroupV15,
oaVoaIfGroupV1,
oaVoaClientIfGroupV3,
oaVoaLineIfGroupV1,
oaModuleGroupV4 }
::= { lumOaCompl 19 }
-- ----------------------------------------------------
-- Minimal Compliance
-- ----------------------------------------------------
lumOaMinimalComplV1 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Minimal implementation requirements for the OA MIB V1."
MODULE
MANDATORY-GROUPS {
oaGeneralGroupV2,
oaIfGroupV5 }
::= { lumOaMinimalCompl 1 }
END