mibs/MIBS/innovaphone/INNO-MIB

576 lines
16 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
INNO-MIB DEFINITIONS ::= BEGIN
-- Innovaphone AG
-- Boeblinger Straße 76
-- D-71065 Sindelfingen
-- info@innovaphone.com
IMPORTS
Counter,TimeTicks,enterprises,IpAddress,Gauge
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
ifIndex
FROM RFC1213-MIB
TRAP-TYPE
FROM RFC-1215;
DisplayString ::= OCTET STRING
innovaphone OBJECT IDENTIFIER ::= { enterprises 6666 }
isdn OBJECT IDENTIFIER ::= { innovaphone 1 }
-- **********************************
-- LAPD table
-- **********************************
l2Table OBJECT-TYPE
SYNTAX SEQUENCE OF L2
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ISDN layer2 table"
::= { isdn 1 }
l2Entry OBJECT-TYPE
SYNTAX L2
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Layer 2 Entry"
INDEX { l2Label }
::= { l2Table 1 }
L2 ::= SEQUENCE {
l2Label DisplayString,
l2State INTEGER,
l2Mode INTEGER,
l1Label DisplayString
}
l2Label OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of this Layer 2 instance"
::= { l2Entry 1 }
l2State OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indication whether the LAPD layer is active"
::= { l2Entry 2 }
l2Mode OBJECT-TYPE
SYNTAX INTEGER {
te(1),
nt(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface mode, either NT or TE"
::= { l2Entry 3 }
l1Label OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of Layer 1 (physical) instance this Layer 2
instance is working on"
::= { l2Entry 4 }
-- **********************************
-- L1 PRI table
-- **********************************
l1PriTable OBJECT-TYPE
SYNTAX SEQUENCE OF L1Pri
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Layer1 table (primary rate interface)"
::= { isdn 2 }
l1PriEntry OBJECT-TYPE
SYNTAX L1Pri
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Layer 1 Entry (primary rate interface)"
INDEX { l1PriLabel }
::= { l1PriTable 1 }
L1Pri ::= SEQUENCE {
l1PriLabel DisplayString,
l1PriState INTEGER,
l1PriErrCrc4 Counter,
l1PriErrRemAlarmInd Counter,
l1PriErrSigLoss Counter,
l1PriErrAlarmInd Counter,
l1PriErrFrameAlignmentTOut Counter,
l1PriErrFrameAlignmentLoss Counter,
l1PriErrSlip Counter,
l1PriTest INTEGER
}
l1PriLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of this Layer 1 instance"
::= { l1PriEntry 1 }
l1PriState OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indication whether the physical layer is active"
::= { l1PriEntry 2 }
l1PriErrCrc4 OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CRC4 check of a received submultiframe failed."
::= { l1PriEntry 3 }
l1PriErrRemAlarmInd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Alarm"
::= { l1PriEntry 4 }
l1PriErrSigLoss OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Loss of signal"
::= { l1PriEntry 5 }
l1PriErrAlarmInd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Indication Signal"
::= { l1PriEntry 6 }
l1PriErrFrameAlignmentTOut OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive Time Out 400 msec"
::= { l1PriEntry 7 }
l1PriErrFrameAlignmentLoss OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Loss of Frame Alignment"
::= { l1PriEntry 8 }
l1PriErrSlip OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive SLIP detected"
::= { l1PriEntry 9 }
l1PriTest OBJECT-TYPE
SYNTAX INTEGER {
noTest(0),
simAlarm(1),
resetAlarms(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Triggers,resets some hardware alarm counters "
::= { l1PriEntry 10 }
-- **********************************
-- L1 BRI table
-- **********************************
l1BriTable OBJECT-TYPE
SYNTAX SEQUENCE OF L1Bri
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Layer1 table (basic rate interface)"
::= { isdn 3 }
l1BriEntry OBJECT-TYPE
SYNTAX L1Bri
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Layer 1 Entry (basic rate rate interface)"
INDEX { l1BriLabel }
::= { l1BriTable 1 }
L1Bri ::= SEQUENCE {
l1BriLabel DisplayString,
l1BriState INTEGER
}
l1BriLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of this Layer 1 instance"
::= { l1BriEntry 1 }
l1BriState OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indication whether the physical layer is active"
::= { l1BriEntry 2 }
-- **********************************
-- L3 table
-- **********************************
l3Table OBJECT-TYPE
SYNTAX SEQUENCE OF L3
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Layer3 table"
::= { isdn 4 }
l3Entry OBJECT-TYPE
SYNTAX L3
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Layer 3 Entry"
INDEX { l3Label }
::= { l3Table 1 }
L3 ::= SEQUENCE {
l3Label DisplayString,
l3Protocol INTEGER,
l3NumBchan INTEGER,
l3NumBchanActive Gauge,
l3CallsBoot Counter
}
l3Label OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of this Layer 3 instance"
::= { l3Entry 1 }
l3Protocol OBJECT-TYPE
SYNTAX INTEGER {
none(0),
other(1),
etsi(3),
qsig(23)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Isdn signalling protocol on this interface"
::= { l3Entry 2 }
l3NumBchan OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of B-channels available"
::= { l3Entry 3 }
l3NumBchanActive OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of B-channels currently active.
May also be understood as number of calls
currently active on this interface."
::= { l3Entry 4 }
l3CallsBoot OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Accumulated Number of Calls on this interface
since last Boot"
::= { l3Entry 5 }
-- **********************************
-- Gateway group
-- **********************************
gateway OBJECT IDENTIFIER ::= { innovaphone 2 }
-- **********************************
-- gatekeeper
-- **********************************
gatekeeper OBJECT IDENTIFIER ::= { gateway 1 }
-- **********************************
-- Voice Interfaces
-- **********************************
voiceIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoiceIf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Voice Interfaces Table. Features either
physical interfaces or aliases."
::= { gatekeeper 1 }
voiceIfEntry OBJECT-TYPE
SYNTAX VoiceIf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Voice Interfaces Entry.Features either
physical interfaces or aliases."
INDEX { voiceIfIndex,
voiceIfAliasIndex }
::= { voiceIfTable 1 }
VoiceIf ::= SEQUENCE {
voiceIfGwName DisplayString,
voiceIfType INTEGER,
voiceIfAddr IpAddress,
voiceIfState INTEGER,
voiceIfNumber DisplayString,
voiceIfName DisplayString,
voiceIfProduct DisplayString,
voiceIfIndex INTEGER,
voiceIfAliasIndex INTEGER
}
voiceIfGwName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Only of interest for aliases to show at which GWxx
an alias has been/will be registered"
::= { voiceIfEntry 1 }
voiceIfType OBJECT-TYPE
SYNTAX INTEGER {
unkown(0), --e.g. if interface>1 is down
if(1), --interface (physical)
ep(2), --endpoint
gk(3), --gatekeeper
gw(4) --gateway
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the interface"
::= { voiceIfEntry 2 }
voiceIfAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ip address, only of interest if interface state
is up"
::= { voiceIfEntry 3 }
voiceIfState OBJECT-TYPE
SYNTAX INTEGER {
down(0),
up(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface state"
::= { voiceIfEntry 4 }
voiceIfNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The E.164 number registered by this interface"
::= { voiceIfEntry 5 }
voiceIfName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The H.323 Name registered by this interface"
::= { voiceIfEntry 6 }
voiceIfProduct OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If available the description of the registering
product"
::= { voiceIfEntry 7 }
voiceIfIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Increasing index of an interface,
utilized as first suboid of entry index."
::= { voiceIfEntry 8 }
voiceIfAliasIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"If interface is an alias, this is the
increasing index of alias at an interface.
Otherwise -1 will be returned.
Utilized as second suboid of entry index."
::= { voiceIfEntry 9 }
-- **********************************
-- Traps
-- **********************************
-- trapDummyGroup doesn't really exist
trapDummyGroup OBJECT IDENTIFIER ::= { innovaphone 3 }
trapDisplayStringParm OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable doesn't exist. Its purpose is to
be syntactically referenced as a variable within
a trap."
::= { trapDummyGroup 1 }
trapIntegerParm OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable doesn't exist. Its purpose is to
be syntactically referenced as a variable within
a trap."
::= { trapDummyGroup 2 }
trapGaugeParm OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable doesn't exist. Its purpose is to
be syntactically referenced as a variable within
a trap."
::= { trapDummyGroup 3 }
innoColdStart TRAP-TYPE
ENTERPRISE innovaphone
DESCRIPTION
"An unexpected restart happened."
::= 0
innoWarmStart TRAP-TYPE
ENTERPRISE innovaphone
DESCRIPTION
"The device has been reset administratively."
::= 1
innoLinkDown TRAP-TYPE
ENTERPRISE innovaphone
VARIABLES { ifIndex }
DESCRIPTION
"An interface link went down (PPP)."
::= 2
innoLinkUp TRAP-TYPE
ENTERPRISE innovaphone
VARIABLES { ifIndex }
DESCRIPTION
"An interface link went up."
::= 3
innoAuthenticationFailure TRAP-TYPE
ENTERPRISE innovaphone
DESCRIPTION
"An Snmp PDU with a wrong community string has
been received."
::= 4
innoIsdnFailure TRAP-TYPE
ENTERPRISE innovaphone
VARIABLES {
trapDisplayStringParm, -- Name of originating interface
trapIntegerParm -- interface is down(0) or up(1)
}
DESCRIPTION
"Obsoleted: This SNMP trap is no longer necessary. Meanwhile it is covered more consistently by innoDiagAlarm and innoDiagAlarmClear.
Removed from on v9hf16."
::= 5
innoDiagAlarm TRAP-TYPE
ENTERPRISE innovaphone
VARIABLES {
trapGaugeParm, -- Alarm Code
trapDisplayStringParm, -- Alarm Source
trapGaugeParm, -- Severity: indeterminate(0),major(1),critical(2)
trapDisplayStringParm -- Alarm Text
}
DESCRIPTION
"This trap corresponds to an alarm under Administration/Diagnostics/Alarms"
::= 6
innoDiagAlarmClear TRAP-TYPE
ENTERPRISE innovaphone
VARIABLES {
trapGaugeParm, -- Alarm Code
trapDisplayStringParm -- Alarm Source
}
DESCRIPTION
"This trap corresponds to an alarm clearing under Administration/Diagnostics/Alarms"
::= 7
END -- Module