mibs/MIBS/junos/ETHER-WIS

629 lines
21 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
ETHER-WIS DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Gauge32, transmission
FROM SNMPv2-SMI
ifIndex
FROM IF-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
sonetMediumStuff2, sonetSectionStuff2,
sonetLineStuff2, sonetFarEndLineStuff2,
sonetPathStuff2, sonetFarEndPathStuff2,
sonetMediumType, sonetMediumLineCoding,
sonetMediumLineType, sonetMediumCircuitIdentifier,
sonetMediumLoopbackConfig, sonetSESthresholdSet,
sonetPathCurrentWidth
FROM SONET-MIB;
etherWisMIB MODULE-IDENTITY
LAST-UPDATED "200309190000Z" -- September 19, 2003
ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
Working Group"
CONTACT-INFO
"WG charter:
http://www.ietf.org/html.charters/hubmib-charter.html
Mailing Lists:
General Discussion: hubmib@ietf.org <mailto:hubmib@ietf.org>
To Subscribe: hubmib-request@ietf.org <mailto:hubmib-request@ietf.org>
In Body: subscribe your_email_address
Chair: Dan Romascanu
Postal: Avaya Inc.
Atidim Technology Park, Bldg. 3
Tel Aviv 61131
Israel
Tel: +972 3 645 8414
E-mail: dromasca@avaya.com <mailto:dromasca@avaya.com>
Editor: C. M. Heard
Postal: 600 Rainbow Dr. #141
Mountain View, CA 94041-2542
USA
Tel: +1 650-964-8391
E-mail: heard@pobox.com <mailto:heard@pobox.com>"
DESCRIPTION
"The objects in this MIB module are used in conjunction
with objects in the SONET-MIB and the MAU-MIB to manage
the Ethernet WAN Interface Sublayer (WIS).
The following reference is used throughout this MIB module:
[IEEE 802.3 Std] refers to:
IEEE Std 802.3, 2000 Edition: 'IEEE Standard for
Information technology - Telecommunications and
information exchange between systems - Local and
metropolitan area networks - Specific requirements -
Part 3: Carrier sense multiple access with collision
detection (CSMA/CD) access method and physical layer
specifications', as amended by IEEE Std 802.3ae-2002,
'IEEE Standard for Carrier Sense Multiple Access with
Collision Detection (CSMA/CD) Access Method and
Physical Layer Specifications - Media Access Control
(MAC) Parameters, Physical Layer and Management
Parameters for 10 Gb/s Operation', 30 August 2002.
Of particular interest are Clause 50, 'WAN Interface
Sublayer (WIS), type 10GBASE-W', Clause 30, '10Mb/s,
100Mb/s, 1000Mb/s, and 10Gb/s MAC Control, and Link
Aggregation Management', and Clause 45, 'Management
Data Input/Output (MDIO) Interface'.
Copyright (C) The Internet Society (2003). This version
of this MIB module is part of RFC 3637 </rfcs/rfc3637.html>; see the RFC
itself for full legal notices."
REVISION "200309190000Z" -- September 19, 2003
DESCRIPTION "Initial version, published as RFC 3637 </rfcs/rfc3637.html>."
::= { transmission 134 }
-- The main sections of the module
etherWisObjects OBJECT IDENTIFIER ::= { etherWisMIB 1 }
etherWisObjectsPath OBJECT IDENTIFIER ::= { etherWisMIB 2 }
etherWisConformance OBJECT IDENTIFIER ::= { etherWisMIB 3 }
-- groups in the Ethernet WIS MIB module
etherWisDevice OBJECT IDENTIFIER ::= { etherWisObjects 1 }
etherWisSection OBJECT IDENTIFIER ::= { etherWisObjects 2 }
etherWisPath OBJECT IDENTIFIER ::= { etherWisObjectsPath 1 }
etherWisFarEndPath OBJECT IDENTIFIER ::= { etherWisObjectsPath 2 }
-- The Device group
-- These objects provide WIS extensions to
-- the SONET-MIB Medium Group.
etherWisDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherWisDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table for Ethernet WIS devices"
::= { etherWisDevice 1 }
etherWisDeviceEntry OBJECT-TYPE
SYNTAX EtherWisDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Ethernet WIS device table. For each
instance of this object there MUST be a corresponding
instance of sonetMediumEntry."
INDEX { ifIndex }
::= { etherWisDeviceTable 1 }
EtherWisDeviceEntry ::=
SEQUENCE {
etherWisDeviceTxTestPatternMode INTEGER,
etherWisDeviceRxTestPatternMode INTEGER,
etherWisDeviceRxTestPatternErrors Gauge32
}
etherWisDeviceTxTestPatternMode OBJECT-TYPE
SYNTAX INTEGER {
none(1),
squareWave(2),
prbs31(3),
mixedFrequency(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable controls the transmit test pattern mode.
The value none(1) puts the the WIS transmit path into
the normal operating mode. The value squareWave(2) puts
the WIS transmit path into the square wave test pattern
mode described in [IEEE 802.3 Std.] subclause 50.3.8.1.
The value prbs31(3) puts the WIS transmit path into the
PRBS31 test pattern mode described in [IEEE 802.3 Std.]
subclause 50.3.8.2. The value mixedFrequency(4) puts the
WIS transmit path into the mixed frequency test pattern
mode described in [IEEE 802.3 Std.] subclause 50.3.8.3.
Any attempt to set this object to a value other than
none(1) when the corresponding instance of ifAdminStatus
has the value up(1) MUST be rejected with the error
inconsistentValue, and any attempt to set the corresponding
instance of ifAdminStatus to the value up(1) when an
instance of this object has a value other than none(1)
MUST be rejected with the error inconsistentValue."
REFERENCE
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
checker, 45.2.2.6, 10G WIS control 2 register (2.7), and
45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
::= { etherWisDeviceEntry 1 }
etherWisDeviceRxTestPatternMode OBJECT-TYPE
SYNTAX INTEGER {
none(1),
prbs31(3),
mixedFrequency(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable controls the receive test pattern mode.
The value none(1) puts the the WIS receive path into the
normal operating mode. The value prbs31(3) puts the WIS
receive path into the PRBS31 test pattern mode described
in [IEEE 802.3 Std.] subclause 50.3.8.2. The value
mixedFrequency(4) puts the WIS receive path into the mixed
frequency test pattern mode described in [IEEE 802.3 Std.]
subclause 50.3.8.3. Any attempt to set this object to a
value other than none(1) when the corresponding instance
of ifAdminStatus has the value up(1) MUST be rejected with
the error inconsistentValue, and any attempt to set the
corresponding instance of ifAdminStatus to the value up(1)
when an instance of this object has a value other than
none(1) MUST be rejected with the error inconsistentValue."
REFERENCE
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
checker, 45.2.2.6, 10G WIS control 2 register (2.7), and
45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
::= { etherWisDeviceEntry 2 }
etherWisDeviceRxTestPatternErrors OBJECT-TYPE
SYNTAX Gauge32 ( 0..65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object counts the number of errors detected when the
WIS receive path is operating in the PRBS31 test pattern
mode. It is reset to zero when the WIS receive path
initially enters that mode, and it increments each time
the PRBS pattern checker detects an error as described in
[IEEE 802.3 Std.] subclause 50.3.8.2 unless its value is
65535, in which case it remains unchanged. This object is
writeable so that it may be reset upon explicit request
of a command generator application while the WIS receive
path continues to operate in PRBS31 test pattern mode."
REFERENCE
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
checker, 45.2.2.7.2, PRBS31 pattern testing ability
(2.8.1), and 45.2.2.8, 10G WIS test pattern error counter
register (2.9)."
::= { etherWisDeviceEntry 3 }
-- The Section group
-- These objects provide WIS extensions to
-- the SONET-MIB Section Group.
etherWisSectionCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherWisSectionCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table for the current state of Ethernet WIS sections."
::= { etherWisSection 1 }
etherWisSectionCurrentEntry OBJECT-TYPE
SYNTAX EtherWisSectionCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the etherWisSectionCurrentTable. For each
instance of this object there MUST be a corresponding
instance of sonetSectionCurrentEntry."
INDEX { ifIndex }
::= { etherWisSectionCurrentTable 1 }
EtherWisSectionCurrentEntry ::=
SEQUENCE {
etherWisSectionCurrentJ0Transmitted OCTET STRING,
etherWisSectionCurrentJ0Received OCTET STRING
}
etherWisSectionCurrentJ0Transmitted OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the 16-octet section trace message that
is transmitted in the J0 byte. The value SHOULD
be '89'h followed by fifteen octets of '00'h
(or some cyclic shift thereof) when the section
trace function is not used, and the implementation
SHOULD use that value (or a cyclic shift thereof)
as a default if no other value has been set."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.8, aJ0ValueTX."
::= { etherWisSectionCurrentEntry 1 }
etherWisSectionCurrentJ0Received OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the 16-octet section trace message that
was most recently received in the J0 byte."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.9, aJ0ValueRX."
::= { etherWisSectionCurrentEntry 2 }
-- The Path group
-- These objects provide WIS extensions to
-- the SONET-MIB Path Group.
etherWisPathCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherWisPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table for the current state of Ethernet WIS paths."
::= { etherWisPath 1 }
etherWisPathCurrentEntry OBJECT-TYPE
SYNTAX EtherWisPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the etherWisPathCurrentTable. For each
instance of this object there MUST be a corresponding
instance of sonetPathCurrentEntry."
INDEX { ifIndex }
::= { etherWisPathCurrentTable 1 }
EtherWisPathCurrentEntry ::=
SEQUENCE {
etherWisPathCurrentStatus BITS,
etherWisPathCurrentJ1Transmitted OCTET STRING,
etherWisPathCurrentJ1Received OCTET STRING
}
etherWisPathCurrentStatus OBJECT-TYPE
SYNTAX BITS {
etherWisPathLOP(0),
etherWisPathAIS(1),
etherWisPathPLM(2),
etherWisPathLCD(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the current status of the
path payload with a bit map that can indicate multiple
defects at once. The bit positions are assigned as
follows:
etherWisPathLOP(0)
This bit is set to indicate that an
LOP-P (Loss of Pointer - Path) defect
is being experienced. Note: when this
bit is set, sonetPathSTSLOP MUST be set
in the corresponding instance of
sonetPathCurrentStatus.
etherWisPathAIS(1)
This bit is set to indicate that an
AIS-P (Alarm Indication Signal - Path)
defect is being experienced. Note: when
this bit is set, sonetPathSTSAIS MUST be
set in the corresponding instance of
sonetPathCurrentStatus.
etherWisPathPLM(1)
This bit is set to indicate that a
PLM-P (Payload Label Mismatch - Path)
defect is being experienced. Note: when
this bit is set, sonetPathSignalLabelMismatch
MUST be set in the corresponding instance of
sonetPathCurrentStatus.
etherWisPathLCD(3)
This bit is set to indicate that an
LCD-P (Loss of Codegroup Delination - Path)
defect is being experienced. Since this
defect is detected by the PCS and not by
the path layer itself, there is no
corresponding bit in sonetPathCurrentStatus."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.18, aPathStatus."
::= { etherWisPathCurrentEntry 1 }
etherWisPathCurrentJ1Transmitted OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the 16-octet path trace message that
is transmitted in the J1 byte. The value SHOULD
be '89'h followed by fifteen octets of '00'h
(or some cyclic shift thereof) when the path
trace function is not used, and the implementation
SHOULD use that value (or a cyclic shift thereof)
as a default if no other value has been set."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.23, aJ1ValueTX."
::= { etherWisPathCurrentEntry 2 }
etherWisPathCurrentJ1Received OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the 16-octet path trace message that
was most recently received in the J1 byte."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.24, aJ1ValueRX."
::= { etherWisPathCurrentEntry 3 }
-- The Far End Path group
-- These objects provide WIS extensions to
-- the SONET-MIB Far End Path Group.
etherWisFarEndPathCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherWisFarEndPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table for the current far-end state of Ethernet WIS
paths."
::= { etherWisFarEndPath 1 }
etherWisFarEndPathCurrentEntry OBJECT-TYPE
SYNTAX EtherWisFarEndPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the etherWisFarEndPathCurrentTable. For each
instance of this object there MUST be a corresponding
instance of sonetFarEndPathCurrentEntry."
INDEX { ifIndex }
::= { etherWisFarEndPathCurrentTable 1 }
EtherWisFarEndPathCurrentEntry ::=
SEQUENCE {
etherWisFarEndPathCurrentStatus BITS
}
etherWisFarEndPathCurrentStatus OBJECT-TYPE
SYNTAX BITS {
etherWisFarEndPayloadDefect(0),
etherWisFarEndServerDefect(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the current status at the
far end of the path using a bit map that can indicate
multiple defects at once. The bit positions are
assigned as follows:
etherWisFarEndPayloadDefect(0)
A far end payload defect (i.e., far end
PLM-P or LCD-P) is currently being signaled
in G1 bits 5-7.
etherWisFarEndServerDefect(1)
A far end server defect (i.e., far end
LOP-P or AIS-P) is currently being signaled
in G1 bits 5-7. Note: when this bit is set,
sonetPathSTSRDI MUST be set in the corresponding
instance of sonetPathCurrentStatus."
REFERENCE
"[IEEE 802.3 Std.], 30.8.1.1.25, aFarEndPathStatus."
::= { etherWisFarEndPathCurrentEntry 1 }
--
-- Conformance Statements
--
etherWisGroups OBJECT IDENTIFIER ::= { etherWisConformance 1 }
etherWisCompliances OBJECT IDENTIFIER ::= { etherWisConformance 2 }
-- Object Groups
etherWisDeviceGroupBasic OBJECT-GROUP
OBJECTS {
etherWisDeviceTxTestPatternMode,
etherWisDeviceRxTestPatternMode
}
STATUS current
DESCRIPTION
"A collection of objects that support test
features required of all WIS devices."
::= { etherWisGroups 1 }
etherWisDeviceGroupExtra OBJECT-GROUP
OBJECTS {
etherWisDeviceRxTestPatternErrors
}
STATUS current
DESCRIPTION
"A collection of objects that support
optional WIS device test features."
::= { etherWisGroups 2 }
etherWisSectionGroup OBJECT-GROUP
OBJECTS {
etherWisSectionCurrentJ0Transmitted,
etherWisSectionCurrentJ0Received
}
STATUS current
DESCRIPTION
"A collection of objects that provide
required information about a WIS section."
::= { etherWisGroups 3 }
etherWisPathGroup OBJECT-GROUP
OBJECTS {
etherWisPathCurrentStatus,
etherWisPathCurrentJ1Transmitted,
etherWisPathCurrentJ1Received
}
STATUS current
DESCRIPTION
"A collection of objects that provide
required information about a WIS path."
::= { etherWisGroups 4 }
etherWisFarEndPathGroup OBJECT-GROUP
OBJECTS {
etherWisFarEndPathCurrentStatus
}
STATUS current
DESCRIPTION
"A collection of objects that provide required
information about the far end of a WIS path."
::= { etherWisGroups 5 }
-- Compliance Statements
etherWisCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for interfaces that include
the Ethernet WIS. Compliance with the following
external compliance statements is prerequisite:
MIB Module Compliance Statement
---------- --------------------
IF-MIB ifCompliance3
IF-INVERTED-STACK-MIB ifInvCompliance
EtherLike-MIB dot3Compliance2
MAU-MIB mauModIfCompl3"
MODULE -- this module
MANDATORY-GROUPS {
etherWisDeviceGroupBasic,
etherWisSectionGroup,
etherWisPathGroup,
etherWisFarEndPathGroup
}
OBJECT etherWisDeviceTxTestPatternMode
SYNTAX INTEGER {
none(1),
squareWave(2),
mixedFrequency(4)
}
DESCRIPTION
"Support for values other than none(1),
squareWave(2), and mixedFrequency(4)
is not required."
OBJECT etherWisDeviceRxTestPatternMode
SYNTAX INTEGER {
none(1),
mixedFrequency(4)
}
DESCRIPTION
"Support for values other than none(1)
and mixedFrequency(4) is not required."
GROUP etherWisDeviceGroupExtra
DESCRIPTION
"Implementation of this group, along with support for
the value prbs31(3) for etherWisDeviceTxTestPatternMode
and etherWisDeviceRxTestPatternMode, is necessary if the
optional PRBS31 test pattern mode is to be supported."
OBJECT etherWisDeviceRxTestPatternErrors
WRITE-SYNTAX Gauge32 ( 0 )
DESCRIPTION
"An implementation is not required to
allow values other than zero to be
written to this object."
MODULE SONET-MIB
MANDATORY-GROUPS {
sonetMediumStuff2,
sonetSectionStuff2,
sonetLineStuff2,
sonetFarEndLineStuff2,
sonetPathStuff2,
sonetFarEndPathStuff2
}
OBJECT sonetMediumType
SYNTAX INTEGER {
sonet(1)
}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, nor is support
for any value other than sonet(1)."
OBJECT sonetMediumLineCoding
SYNTAX INTEGER {
sonetMediumNRZ(4)
}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, nor is support
for any value other than sonetMediumNRZ(4)."
OBJECT sonetMediumLineType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sonetMediumCircuitIdentifier
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT sonetMediumLoopbackConfig
SYNTAX BITS {
sonetNoLoop(0),
sonetFacilityLoop(1)
}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, nor is support for values
other than sonetNoLoop(0) and sonetFacilityLoop(1)."
OBJECT sonetSESthresholdSet
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one
of the enumerated values need be supported."
OBJECT sonetPathCurrentWidth
SYNTAX INTEGER {
sts192cSTM64(6)
}
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, nor is support
for any value other than sts192cSTM64(6)."
::= { etherWisCompliances 1 }
END