mibs/MIBS/junos/JUNIPER-ALARM-MIB

186 lines
4.1 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--
-- Juniper Enterprise Specific MIB: Alarm MIB
--
-- Copyright (c) 2001-2003, Juniper Networks, Inc.
-- All rights reserved.
--
-- The contents of this document are subject to change without notice.
--
JUNIPER-ALARM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Gauge32
FROM SNMPv2-SMI
TimeStamp
FROM SNMPv2-TC
jnxMibs
FROM JUNIPER-SMI;
jnxAlarms MODULE-IDENTITY
LAST-UPDATED "200307182153Z" -- Fri Jul 18 21:53:46 2003 UTC
ORGANIZATION "Juniper Networks, Inc."
CONTACT-INFO
" Juniper Technical Assistance Center
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, CA 94089
E-mail: support@juniper.net"
DESCRIPTION
"This is Juniper Networks' implementation of enterprise
specific MIB for alarms from the router chassis box."
::= { jnxMibs 4 }
-- ::= { jnxAlarms 1 } This OID is obsolete.
--
-- Craft Alarms
--
jnxCraftAlarms OBJECT IDENTIFIER ::= { jnxAlarms 2 }
jnxAlarmRelayMode OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- other or unknown
passOn(2), -- alarms being passed on
cutOff(3) -- alarms being cut off
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm relay mode of the craft interface
panel for both yellow and red alarms.
Both yellow and red alarms could be cut off
by a front panel Alarm Cutoff / Lamp Test
(ACO/LT) button.
In the pass-on mode, the alarm relay will be
activated to pass on the yellow or red alarms.
In the cut-off mode, both yellow and red alarms
will be cut off from the alarm relays which are
normally connected to audible sirens or visual
flashing devices."
::= { jnxCraftAlarms 1 }
jnxYellowAlarms OBJECT IDENTIFIER ::= { jnxCraftAlarms 2 }
jnxYellowAlarmState OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- alarm state is unknown
off(2), -- alarm is off
on(3) -- alarm is on
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The yellow alarm state on the craft interface
panel.
The yellow alarm is on when there is some
system warning such as maintenance alert or
significant temperature increase.
This yellow alarm state could be turned off
by the ACO/LT (Alarm Cut Off / Lamp Test) button
on the front panel module."
::= { jnxYellowAlarms 1 }
jnxYellowAlarmCount OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of currently active and non-silent
yellow alarms.
This object is independent of the ACO/LT (Alarm
Cut Off / Lamp Test) button."
::= { jnxYellowAlarms 2 }
jnxYellowAlarmLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the yellow alarm
last changed - either from off to on or vice
versa. Zero if unknown or never changed since
the agent was up."
::= { jnxYellowAlarms 3 }
jnxRedAlarms OBJECT IDENTIFIER ::= { jnxCraftAlarms 3 }
jnxRedAlarmState OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- alarm state is unknown
off(2), -- alarm is off
on(3) -- alarm is on
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The red alarm indication on the craft interface
panel.
The red alarm is on when there is some system
failure or power supply failure or the system
is experiencing a hardware malfunction or some
threshold is being exceeded.
This red alarm state could be turned off by the
ACO/LT (Alarm Cut Off / Lamp Test) button on the
front panel module."
::= { jnxRedAlarms 1 }
jnxRedAlarmCount OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of currently active and non-silent
red alarms.
This object is independent of the ACO/LT (Alarm
Cut Off / Lamp Test) button."
::= { jnxRedAlarms 2 }
jnxRedAlarmLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the red alarm
last changed - either from off to on or vice
versa. Zero if unknown or never changed since
the agent was up."
::= { jnxRedAlarms 3 }
END