mibs/MIBS/junose/ATM2-MIB

3247 lines
116 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
ATM2-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Gauge32, Counter32, Integer32
FROM SNMPv2-SMI
TruthValue, RowStatus, TimeStamp
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
InterfaceIndex, InterfaceIndexOrZero, ifIndex
FROM IF-MIB
atmMIBObjects, atmInterfaceConfEntry,
atmVplEntry, atmVplVpi,
atmVclEntry, atmVclVpi, atmVclVci,
atmVpCrossConnectEntry, atmVcCrossConnectEntry
FROM ATM-MIB
AtmAddr, AtmSigDescrParamIndex,
AtmInterfaceType, AtmIlmiNetworkPrefix,
AtmVcIdentifier, AtmVpIdentifier,
AtmTrafficDescrParamIndex
FROM ATM-TC-MIB;
atm2MIB MODULE-IDENTITY
LAST-UPDATED "200309230000Z"
ORGANIZATION "IETF AToMMIB Working Group"
CONTACT-INFO
"AToMMIB WG
http://www.ietf.org/html.charters/atommib-charter.html
Editors:
Faye Ly
Postal: Pedestal Networks
6503 Dumbarton Circle
Fremont, CA 94555
USA
Tel: +1 510 896 2908
E-Mail: faye@pedestalnetworks.com
Michael Noto
Postal: Cisco Systems
170 W. Tasman Drive
San Jose, CA 95134-1706
USA
E-mail: mnoto@cisco.com
Andrew Smith
Postal: Consultant
E-Mail: ah_smith@acm.org
Ethan Mickey Spiegel
Postal: Cisco Systems
170 W. Tasman Drive
San Jose, CA 95134-1706
USA
Tel: +1 408 526 6408
Fax: +1 408 526 6488
E-Mail: mspiegel@cisco.com
Kaj Tesink
Postal: Telcordia Technologies
331 Newman Springs Road
Red Bank, NJ 07701
USA
Tel: +1 732 758 5254
E-mail: kaj@research.telcordia.com"
DESCRIPTION
"Copyright (C) The Internet Society (2003). This version of
this MIB module is part of RFC 3606; see the RFC itself for
full legal notices.
This MIB Module is a supplement to the ATM-MIB
defined in RFC 2515."
REVISION "200309230000Z"
DESCRIPTION
"Initial version of this MIB, published as RFC 3606."
::= { atmMIBObjects 14 }
atm2MIBObjects OBJECT IDENTIFIER ::= {atm2MIB 1}
atm2MIBTraps OBJECT IDENTIFIER ::= {atm2MIB 2}
-- This ATM2-MIB Module consists of the following tables,
-- plus ATM trap support:
-- 1. atmSvcVpCrossConnectTable
-- 2. atmSvcVcCrossConnectTable
-- 3. atmSigStatTable
-- 4. atmSigSupportTable
-- 5. atmSigDescrParamTable
-- 6. atmIfRegisteredAddrTable
-- 7. atmVclAddrTable
-- 8. atmAddrVclTable
-- 9. atmVplStatTable
-- 10. atmVplLogicalPortTable
-- 11. atmVclStatTable
-- 12. atmAal5VclStatTable
-- 13. atmVclGenTable
-- 14. atmInterfaceExtTable
-- 15. atmIlmiSrvcRegTable
-- 16. atmIlmiNetworkPrefixTable
-- 17. atmSwitchAddressTable
-- 18. atmVpCrossConnectXTable
-- 19. atmVcCrossConnectXTable
-- 20. atmCurrentlyFailingPVplTable
-- 21. atmCurrentlyFailingPVclTable
-- 1. ATM VPL SVC Cross-Connect Table
atmSvcVpCrossConnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF
AtmSvcVpCrossConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM SVPC Cross-Connect table. A
bi-directional VP cross-connect between two
switched VPLs is modeled as one entry in this
table. A Soft PVPC cross-connect, between a
soft permanent VPL and a switched VPL, is
also modeled as one entry in this table."
::= { atm2MIBObjects 1 }
atmSvcVpCrossConnectEntry OBJECT-TYPE
SYNTAX AtmSvcVpCrossConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM SVPC Cross-Connect table.
This entry is used to model a bi-directional
ATM VP cross-connect between two VPLs."
INDEX { atmSvcVpCrossConnectIndex,
atmSvcVpCrossConnectLowIfIndex,
atmSvcVpCrossConnectLowVpi,
atmSvcVpCrossConnectHighIfIndex,
atmSvcVpCrossConnectHighVpi }
::= { atmSvcVpCrossConnectTable 1 }
AtmSvcVpCrossConnectEntry ::= SEQUENCE {
atmSvcVpCrossConnectIndex INTEGER,
atmSvcVpCrossConnectLowIfIndex InterfaceIndex,
atmSvcVpCrossConnectLowVpi AtmVpIdentifier,
atmSvcVpCrossConnectHighIfIndex InterfaceIndex,
atmSvcVpCrossConnectHighVpi AtmVpIdentifier,
atmSvcVpCrossConnectCreationTime TimeStamp,
atmSvcVpCrossConnectRowStatus RowStatus
}
atmSvcVpCrossConnectIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value to identify this SVPC
cross-connect. For each VP associated
with this cross-connect, the agent reports
this cross-connect index value in the
atmVplCrossConnectIdentifer attribute of the
corresponding atmVplTable entries."
::= { atmSvcVpCrossConnectEntry 1 }
atmSvcVpCrossConnectLowIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the
ifIndex value of the ATM interface port for this
SVPC cross-connect. The term low implies
that this ATM interface has the numerically lower
ifIndex value than the other ATM interface
identified in the same atmSvcVpCrossConnectEntry."
::= { atmSvcVpCrossConnectEntry 2 }
atmSvcVpCrossConnectLowVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the VPI
value associated with the SVPC cross-connect
at the ATM interface that is identified by
atmSvcVpCrossConnectLowIfIndex. The VPI value
cannot exceed the number supported by the
atmInterfaceCurrentMaxSvpcVpi at the low ATM interface
port."
::= { atmSvcVpCrossConnectEntry 3 }
atmSvcVpCrossConnectHighIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the
ifIndex value of the ATM interface port for
this SVC VP cross-connect. The term high
implies that this ATM interface has the
numerically higher ifIndex value than the
other ATM interface identified in the same
atmSvcVpCrossConnectEntry."
::= { atmSvcVpCrossConnectEntry 4 }
atmSvcVpCrossConnectHighVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the VPI
value associated with the SVPC cross-connect
at the ATM interface that is identified by
atmSvcVpCrossConnectHighIfIndex. The VPI value
cannot exceed the number supported by the
atmInterfaceCurrentMaxSvpcVpi at the high ATM interface
port."
::= { atmSvcVpCrossConnectEntry 5 }
atmSvcVpCrossConnectCreationTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the sysUpTime object
at the time this bi-directional SVPC
cross-connect was created. If the current
state was entered prior to the last
re-initialization of the agent, then this
object contains a zero value."
::= { atmSvcVpCrossConnectEntry 6 }
atmSvcVpCrossConnectRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to delete rows in the
atmSvcVpCrossConnectTable."
::= { atmSvcVpCrossConnectEntry 7 }
-- 2. ATM VCL SVC Cross-Connect Table
atmSvcVcCrossConnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSvcVcCrossConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM SVCC Cross-Connect table. A
bi-directional VC cross-connect between two
switched VCLs is modeled as one entry in
this table. A Soft PVCC cross-connect,
between a soft permanent VCL and a switched
VCL, is also modeled as one entry in this
table."
::= { atm2MIBObjects 2 }
atmSvcVcCrossConnectEntry OBJECT-TYPE
SYNTAX AtmSvcVcCrossConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM SVCC Cross-Connect table.
This entry is used to model a bi-directional ATM
VC cross-connect between two VCLs."
INDEX { atmSvcVcCrossConnectIndex,
atmSvcVcCrossConnectLowIfIndex,
atmSvcVcCrossConnectLowVpi,
atmSvcVcCrossConnectLowVci,
atmSvcVcCrossConnectHighIfIndex,
atmSvcVcCrossConnectHighVpi,
atmSvcVcCrossConnectHighVci }
::= { atmSvcVcCrossConnectTable 1 }
AtmSvcVcCrossConnectEntry ::= SEQUENCE {
atmSvcVcCrossConnectIndex INTEGER,
atmSvcVcCrossConnectLowIfIndex InterfaceIndex,
atmSvcVcCrossConnectLowVpi AtmVpIdentifier,
atmSvcVcCrossConnectLowVci AtmVcIdentifier,
atmSvcVcCrossConnectHighIfIndex InterfaceIndex,
atmSvcVcCrossConnectHighVpi AtmVpIdentifier,
atmSvcVcCrossConnectHighVci AtmVcIdentifier,
atmSvcVcCrossConnectCreationTime TimeStamp,
atmSvcVcCrossConnectRowStatus RowStatus
}
atmSvcVcCrossConnectIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value to identify this SVCC cross-connect.
For each VP associated with this cross-connect, the
agent reports this cross-connect index value in the
atmVclCrossConnectIdentifier attribute of the
corresponding atmVplTable entries."
::= { atmSvcVcCrossConnectEntry 1 }
atmSvcVcCrossConnectLowIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the
ifIndex value of the ATM interface port for this
SVCC cross-connect. The term low implies that
this ATM interface has the numerically lower
ifIndex value than the other ATM interface
identified in the same atmSvcVcCrossConnectEntry."
::= { atmSvcVcCrossConnectEntry 2 }
atmSvcVcCrossConnectLowVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the VPI
value associated with the SVCC cross-connect
at the ATM interface that is identified by
atmSvcVcCrossConnectLowIfIndex. The VPI value
cannot exceed the number supported by the
atmInterfaceCurrentMaxSvccVpi at the low ATM interface
port."
::= { atmSvcVcCrossConnectEntry 3 }
atmSvcVcCrossConnectLowVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the VCI
value associated with the SVCC cross-connect
at the ATM interface that is identified by
atmSvcVcCrossConnectLowIfIndex. The VCI value
cannot exceed the number supported by the
atmInterfaceCurrentMaxSvccVci at the low ATM interface
port."
::= { atmSvcVcCrossConnectEntry 4 }
atmSvcVcCrossConnectHighIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the
ifIndex value for the ATM interface port for
this SVCC cross-connect. The term high implies
that this ATM interface has the numerically
higher ifIndex value than the other ATM interface
identified in the same atmSvcVcCrossConnectEntry."
::= { atmSvcVcCrossConnectEntry 5 }
atmSvcVcCrossConnectHighVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the VPI
value associated with the SVCC cross-connect
at the ATM interface that is identified by
atmSvcVcCrossConnectHighIfIndex. The VPI value
cannot exceed the number supported by the
atmInterfaceCurrentMaxSvccVpi at the high ATM interface
port."
::= { atmSvcVcCrossConnectEntry 6 }
atmSvcVcCrossConnectHighVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the VCI
value associated with the SVCC cross-connect
at the ATM interface that is identified by
atmSvcVcCrossConnectHighIfIndex. The VCI value
cannot exceed the number supported by the
atmInterfaceMaxVciBits at the high ATM interface
port."
::= { atmSvcVcCrossConnectEntry 7 }
atmSvcVcCrossConnectCreationTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the sysUpTime object
at the time this bi-directional SVCC
cross-connect was created. If the current
state was entered prior to the last
re-initialization of the agent, then this
object contains a zero value."
::= { atmSvcVcCrossConnectEntry 8 }
atmSvcVcCrossConnectRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to delete rows in the
atmSvcVcCrossConnectTable."
::= { atmSvcVcCrossConnectEntry 9 }
-- 3. ATM Interface Signalling Statistics Table --
atmSigStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSigStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ATM interface signalling
statistics, one entry per ATM signalling
interface."
::= { atm2MIBObjects 3 }
atmSigStatEntry OBJECT-TYPE
SYNTAX AtmSigStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This list contains signalling statistics variables."
INDEX { ifIndex }
::= { atmSigStatTable 1}
AtmSigStatEntry ::= SEQUENCE {
atmSigSSCOPConEvents Counter32,
atmSigSSCOPErrdPdus Counter32,
atmSigDetectSetupAttempts Counter32,
atmSigEmitSetupAttempts Counter32,
atmSigDetectUnavailRoutes Counter32,
atmSigEmitUnavailRoutes Counter32,
atmSigDetectUnavailResrcs Counter32,
atmSigEmitUnavailResrcs Counter32,
atmSigDetectCldPtyEvents Counter32,
atmSigEmitCldPtyEvents Counter32,
atmSigDetectMsgErrors Counter32,
atmSigEmitMsgErrors Counter32,
atmSigDetectClgPtyEvents Counter32,
atmSigEmitClgPtyEvents Counter32,
atmSigDetectTimerExpireds Counter32,
atmSigEmitTimerExpireds Counter32,
atmSigDetectRestarts Counter32,
atmSigEmitRestarts Counter32,
atmSigInEstabls Counter32,
atmSigOutEstabls Counter32
}
atmSigSSCOPConEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SSCOP Connection Events Counter. This counter counts
the sum of the following errors:
1) SSCOP Connection Disconnect Counter
The abnormal occurrence of this event is
characterized by the expiry of Timer_NO_RESPONSE.
(This event is communicated to the layer management
with MAA-ERROR code P. See ITU-T Q.2110.)
2) SSCOP Connection Initiation Failure
This condition indicates the inability to establish
an SSCOP connection. This event occurs whenever the
number of expiries of the connection control timer
(Timer_CC) equals or exceeds the MaxCC, or upon
receipt of a connection reject message BGREJ PDU.
(This event is communicated to layer management with
MAA-ERROR code O. See ITU-T Q.2110.)
3) SSCOP Connection Re-Establ/Resynch
This event occurs upon receipt of a BGN PDU or
RS PDU."
REFERENCE
"ITU-T Recommendation Q.2110, Broadband
Integrated Services Digital Network
(B-ISDN) - ATM Adaptation Layer - Service
Specific Connection Oriented Protocol (SSCOP)
Specification, July 1994."
::= { atmSigStatEntry 1}
atmSigSSCOPErrdPdus OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SSCOP Errored PDUs Counter. This counter counts the
sum of the following errors:
1) Invalid PDUs.
These are defined in SSCOP and consist of PDUs
with an incorrect length (MAA-ERROR code U), an
undefined PDU type code, or that are not 32-bit
aligned.
2) PDUs that result in MAA-ERROR codes and are
discarded.
See MAA-ERROR codes A-D, F-M, and Q-T defined in
ITU-T Q.2110."
REFERENCE
"ITU-T Recommendation Q.2110, Broadband
Integrated Services Digital Network
(B-ISDN) - ATM Adaptation Layer - Service
Specific Connection Oriented Protocol (SSCOP)
Specification, July 1994."
::= { atmSigStatEntry 2 }
atmSigDetectSetupAttempts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Call Setup Attempts Counter. This counter counts
the number of call setup attempts (both successful
and unsuccessful) detected on this interface."
::= { atmSigStatEntry 3 }
atmSigEmitSetupAttempts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Call Setup Attempts Counter. This counter counts
the number of call setup attempts (both successful
and unsuccessful) transmitted on this interface."
::= { atmSigStatEntry 4 }
atmSigDetectUnavailRoutes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Route Unavailability detected on this interface.
This counter is incremented when a RELEASE, RELEASE COMPLETE
(only when not preceded by a RELEASE message for the same
call), ADD PARTY REJECT, or STATUS message that
contains one of the following cause code values is
received (Note: These cause values
apply to both UNI3.0 and UNI3.1):
Cause Value Meaning
1 unallocated (unassigned) number
2 no route to specified transit network
3 no route to destination
NOTE: For this counter, RELEASE COMPLETE
messages that are a reply to a previous RELEASE
message and contain the same cause value, are
redundant (for counting purposes) and should not
be counted."
::= { atmSigStatEntry 5 }
atmSigEmitUnavailRoutes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Route Unavailability transmitted from this
interface. This counter is incremented when a RELEASE,
RELEASE COMPLETE (only when not preceded by a RELEASE
message for the same call), ADD PARTY REJECT, or
STATUS message that contains one of the following cause
code values is transmitted (Note: These cause values apply
to both UNI3.0 and UNI3.1):
Cause Value Meaning
1 unallocated (unassigned) number
2 no route to specified transit network
3 no route to destination
NOTE: For this counter, RELEASE COMPLETE
messages that are a reply to a previous RELEASE
message and contain the same cause value, are
redundant (for counting purposes) and should not
be counted."
::= { atmSigStatEntry 6 }
atmSigDetectUnavailResrcs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Resource Unavailability detected on this
interface. This counter is incremented when a RELEASE,
RELEASE COMPLETE (only when not preceded by a RELEASE
message for the same call), ADD PARTY REJECT, or
STATUS message that contains one of the following
cause code values is received (Note: These cause
values apply to both UNI3.0 and UNI3.1 unless
otherwise stated):
Cause Value Meaning
35 requested VPCI/VCI not available
37 user cell rate not available (UNI3.1
only)
38 network out of order
41 temporary failure
45 no VPCI/VCI available
47 resource unavailable, unspecified
49 Quality of Service unavailable
51 user cell rate not available (UNI3.0
only)
58 bearer capability not presently
available
63 Service or option not available,
unspecified
92 too many pending add party requests
NOTE: For this counter, RELEASE COMPLETE
messages that are a reply to a previous RELEASE
message and contain the same cause value, are
redundant (for counting purposes) and should not
be counted."
::= { atmSigStatEntry 7 }
atmSigEmitUnavailResrcs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Resource Unavailability transmitted from this
interface. This counter is incremented when a RELEASE,
RELEASE COMPLETE (only when not preceded by a RELEASE message
for the same call), ADD PARTY REJECT, or STATUS message that
contains one of the following cause code values is transmitted
(Note: These cause values apply to both UNI3.0 and UNI3.1
unless otherwise stated):
Cause Value Meaning
35 requested VPCI/VCI not available
37 user cell rate not available (UNI3.1
only)
38 network out of order
41 temporary failure
45 no VPCI/VCI available
47 resource unavailable, unspecified
49 Quality of Service unavailable
51 user cell rate not available (UNI3.0
only)
58 bearer capability not presently
available
63 Service or option not available,
unspecified
92 too many pending add party requests
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant (for counting purposes) and should not be
counted."
::= { atmSigStatEntry 8 }
atmSigDetectCldPtyEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Called Party Responsible For Unsuccessful Call
detected on this interface. This counter is incremented when a
RELEASE, RELEASE COMPLETE (only when not preceded by a RELEASE
message for the same call), ADD PARTY REJECT, or STATUS message
that contains one of the following cause code values is
received (Note: These cause values apply to both UNI3.0 and
UNI3.1):
Cause Value Meaning
17 user busy
18 no user responding
21 call rejected
22 number changed
23 user rejects all calls with calling
line identification restriction (CLIR)
27 destination out of order
31 normal, unspecified
88 incompatible destination
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant (for counting purposes) and should not be
counted.
Note: Cause Value #30 'response to STATUS ENQUIRY' was not
included in this memo since it did not apply to a hard
failure."
::= { atmSigStatEntry 9 }
atmSigEmitCldPtyEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Called Party Responsible For Unsuccessful Call
transmitted from this interface. This counter is incremented
when a RELEASE, RELEASE COMPLETE (only when not preceded by a
RELEASE message for the same call), ADD PARTY REJECT, or STATUS
message that contains one of the following cause code values is
transmitted (Note: These cause values apply to both UNI3.0 and
UNI3.1):
Cause Value Meaning
17 user busy
18 no user responding
21 call rejected
22 number changed
23 user rejects all calls with calling
line identification restriction (CLIR)
27 destination out of order
31 normal, unspecified
88 incompatible destination
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant (for counting purposes) and should not be
counted.
Note: Cause Value #30 'response to STATUS ENQUIRY' was not
included in this memo since it did not apply to a hard failure."
::= { atmSigStatEntry 10 }
atmSigDetectMsgErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Incorrect Messages detected on this interface. The
Incorrect Messages Counter reflects any sort of incorrect
information in a message. This includes:
- RELEASE, RELEASE COMPLETE, ADD PARTY REJECT,
and STATUS messages transmitted, that contain any of
the Cause values listed below.
- Ignored messages. These messages are dropped
because the message was so damaged that it could
not be further processed. A list of dropped
messages is compiled below:
1. Message with invalid protocol discriminator
2. Message with errors in the call reference I.E.
- Bits 5-8 of the first octet not equal to
'0000'
- Bits 1-4 of the first octet indicating a
length other than 3 octets
- RELEASE COMPLETE message received with a
call reference that does not relate to a
call active or in progress
- SETUP message received with call reference
flag incorrectly set to 1
- SETUP message received with a call
reference for a call that is already
active or in progress.
3. Message too short
The following cause values are monitored by this counter (Note:
These cause values apply to both UNI3.0 and UNI3.1 unless
otherwise stated):
Cause Value Meaning
10 VPCI/VCI unacceptable (UNI3.0 only)
36 VPCI/VCI assignment failure (UNI3.1 only)
81 invalid call reference value
82 identified channel does not exist
89 invalid endpoint reference
96 mandatory information element is missing
97 message type non-existent or not
implemented
99 information element non-existent or not
implemented
100 invalid information element contents
101 message not compatible with call state
104 incorrect message length
111 protocol error, unspecified
NOTE: For this counter, RELEASE COMPLETE messages that are
a reply to a previous RELEASE message and contain the same
cause value, are redundant (for counting purposes) and
should not be counted."
::= { atmSigStatEntry 11 }
atmSigEmitMsgErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Incorrect Messages transmitted on this interface.
The Incorrect Messages Counter reflects any sort of incorrect
information in a message. This includes:
- RELEASE, RELEASE COMPLETE, ADD PARTY REJECT,
and STATUS messages transmitted or
received, that contain any of the Cause values
listed below.
- Ignored messages. These messages are dropped
because the message was so damaged that it could
not be further processed. A list of dropped
messages is compiled below:
1. Message with invalid protocol discriminator
2. Message with errors in the call reference I.E.
- Bits 5-8 of the first octet not equal to
'0000'
- Bits 1-4 of the first octet indicating a
length other than 3 octets
- RELEASE COMPLETE message received with a
call reference that does not relate to a
call active or in progress
- SETUP message received with call reference
flag incorrectly set to 1
- SETUP message received with a call
reference for a call that is already
active or in progress.
3. Message too short
The following cause values are monitored by this counter
(Note: These cause values apply to both UNI3.0 and UNI3.1
unless otherwise stated):
Cause Value Meaning
10 VPCI/VCI unacceptable (UNI3.0 only)
36 VPCI/VCI assignment failure (UNI3.1 only)
81 invalid call reference value
82 identified channel does not exist
89 invalid endpoint reference
96 mandatory information element is missing
97 message type non-existent or not
implemented
99 information element non-existent or not
implemented
100 invalid information element contents
101 message not compatible with call state
104 incorrect message length
111 protocol error, unspecified
NOTE: For this counter, RELEASE COMPLETE messages that are
a reply to a previous RELEASE message and contain the same
cause value, are redundant (for counting purposes) and
should not be counted."
::= { atmSigStatEntry 12 }
atmSigDetectClgPtyEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Calling Party Events detected on this interface.
This counter monitors error events that occur due to the
originating user doing something wrong. This counter is
incremented when a RELEASE, RELEASE COMPLETE (only when not
preceded by a RELEASE message for the same call), ADD PARTY
REJECT, or STATUS message that contains one of the following
cause code values is received (Note: These cause values
apply to both UNI3.0 and UNI3.1):
Cause Value Meaning
28 invalid number format (address incomplete)
43 access information discarded
57 bearer capability not authorized
65 bearer capability not implemented
73 unsupported combination of traffic
parameters
78 AAL parameters cannot be supported (UNI3.1
only)
91 invalid transit network selection
93 AAL parameters cannot be supported (UNI3.0
only)
NOTE: For this counter, RELEASE COMPLETE messages that
are a reply to a previous RELEASE message and contain
the same cause value, are redundant (for counting purposes)
and should not be counted."
::= { atmSigStatEntry 13 }
atmSigEmitClgPtyEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Calling Party Events transmitted from this interface.
This counter monitors error events that occur due to the
originating user doing something wrong. This counter is
incremented when a RELEASE, RELEASE COMPLETE (only when not
preceded by a RELEASE message for the same call), ADD PARTY
REJECT, or STATUS message that contains one of the following
cause code values is transmitted (Note: These cause values
apply to both UNI3.0 and UNI3.1):
Cause Value Meaning
28 invalid number format (address incomplete)
43 access information discarded
57 bearer capability not authorized
65 bearer capability not implemented
73 unsupported combination of traffic
parameters
78 AAL parameters cannot be supported (UNI3.1
only)
91 invalid transit network selection
93 AAL parameters cannot be supported (UNI3.0
only)
NOTE: For this counter, RELEASE COMPLETE messages that are
a reply to a previous RELEASE message and contain the same
cause value, are redundant (for counting purposes) and
should not be counted."
::= { atmSigStatEntry 14 }
atmSigDetectTimerExpireds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Timer Expiries detected on this interface. The Timer
Expiries Counter provides a count of network timer expiries, and
to some extent, host or switch timer expiries. The conditions
for incrementing this counter are:
- Expiry of any network timer
- Receipt of a RELEASE or RELEASE COMPLETE
message with Cause #102, 'recovery on
timer expiry'.
NOTE: For this counter, RELEASE COMPLETE messages that are
a reply to a previous RELEASE message and contain the same
cause value, are redundant (for counting purposes) and
should not be counted."
::= { atmSigStatEntry 15 }
atmSigEmitTimerExpireds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Timer Expiries transmitted from this interface.
The Timer Expiries Counter provides a count of network timer
expiries, and to some extent, host or switch timer expiries.
The conditions for incrementing this counter are:
- Expiry of any network timer
- Receipt of a RELEASE or RELEASE COMPLETE
message with Cause #102, 'recovery on
timer expiry'.
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant (for counting purposes) and should not be
counted."
::= { atmSigStatEntry 16 }
atmSigDetectRestarts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Restart Activity errors detected on this interface.
The Restart Activity Counter provides a count of host, switch,
or network restart activity. This counter is incremented when
receiving a RESTART message."
::= { atmSigStatEntry 17 }
atmSigEmitRestarts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Restart Activity errors transmitted from this
interface. The Restart Activity Counter provides a count of
host, switch, or network restart activity. This counter is
incremented when transmitting a RESTART message."
::= { atmSigStatEntry 18 }
atmSigInEstabls OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of SVCs established at this signalling entity for
incoming connections."
::= { atmSigStatEntry 19 }
atmSigOutEstabls OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of SVCs established at this signalling entity for
outgoing connections."
::= { atmSigStatEntry 20 }
-- 4. ATM Interface Signalling Support Table
--
-- This table provides information to support
-- the signalling process which is used to establish
-- ATM Switched Virtual Connections (SVCs).
atmSigSupportTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSigSupportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ATM local interface configuration
parameters, one entry per ATM signalling interface."
::= { atm2MIBObjects 4 }
atmSigSupportEntry OBJECT-TYPE
SYNTAX AtmSigSupportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This list contains signalling configuration parameters
and state variables."
INDEX { ifIndex }
::= { atmSigSupportTable 1}
AtmSigSupportEntry ::= SEQUENCE {
atmSigSupportClgPtyNumDel INTEGER,
atmSigSupportClgPtySubAddr INTEGER,
atmSigSupportCldPtySubAddr INTEGER,
atmSigSupportHiLyrInfo INTEGER,
atmSigSupportLoLyrInfo INTEGER,
atmSigSupportBlliRepeatInd INTEGER,
atmSigSupportAALInfo INTEGER,
atmSigSupportPrefCarrier OCTET STRING
}
atmSigSupportClgPtyNumDel OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the Calling Party Number
Information Element is transferred to the called party
address. The value of this object can be:
- enabled(1) This Information Element is transferred
to the called party
- disabled(2) This Information Element is NOT
transferred to the called party."
::= { atmSigSupportEntry 1 }
atmSigSupportClgPtySubAddr OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether to accept and transfer the Calling
Party Subaddress Information Element from the calling party to
the called party. Calling party subaddress information shall
only be transferred to the called party if calling party number
delivery is enabled (i.e., atmSigSupportClgPtyNumDel =
'enabled(1)'. The value of this object can be:
- enabled(1) This Information Element is transferred
to the called party
- disabled(2) This Information Element is NOT
transferred to the called party."
::= { atmSigSupportEntry 2 }
atmSigSupportCldPtySubAddr OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether to accept, transfer, and deliver
the Called Party Subaddress Information Element from the calling
party to the called party. The value of this object can be:
- enabled(1) This Information Element is transferred
to the called party
- disabled(2) This Information Element is NOT
transferred to the called party."
::= { atmSigSupportEntry 3 }
atmSigSupportHiLyrInfo OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether to accept, transfer, and deliver
the Broadband High Layer Information Element from the calling
party to the called party. The value of this object can be:
- enabled(1) This Information Element is transferred
to the called party
- disabled(2) This Information Element is NOT
transferred to the called party."
::= { atmSigSupportEntry 4 }
atmSigSupportLoLyrInfo OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether to accept, transfer, and deliver
the Broadband Low Layer Information Element from the calling
party to the called party. The value of this object can be:
- enabled(1) This Information Element is transferred
to the called party
- disabled(2) This Information Element is NOT
transferred to the called party."
::= { atmSigSupportEntry 5 }
atmSigSupportBlliRepeatInd OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether to accept, transfer, and deliver
the Broadband Repeat Indicator with two or three instances of
the Broadband Low Layer Information Element for low layer
information selection from the calling party to the called
party. This object's value should always be disabled(2) if
the value of atmSigSupportLolyrInfo is disabled(2).
The value of this object can be:
- enabled(1) This Information Element is transferred
to the called party
- disabled(2) This Information Element is NOT
transferred to the called party."
::= { atmSigSupportEntry 6 }
atmSigSupportAALInfo OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether to accept, transfer, and deliver
the ATM Adaptation Layer Parameters Information Element from the
calling party to the called party. The value of this object can
be:
- enabled(1) This Information Element is transferred
to the called party
- disabled(2) This Information Element is NOT
transferred to the called party."
::= { atmSigSupportEntry 7 }
atmSigSupportPrefCarrier OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0|4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter identifies the carrier to which intercarrier
calls originated from this interface are routed when transit
network selection information is not provided by the calling
party. If a Carrier Identification Code (CIC) is used the
parameter shall contain the CIC. For three-digit CICs, the first
octet shall be '0' and the CIC is contained in the three
following octets. If the preferred carrier feature is not
supported the value is a zero-length string."
::= { atmSigSupportEntry 8 }
-- 5. ATM Signalling Descriptor Parameter Table
atmSigDescrParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSigDescrParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table contains signalling capabilities of VCLs except the
Traffic Descriptor. Traffic descriptors are described in
the atmTrafficDescrParamTable."
REFERENCE
"ATM User-Network Interface Specification, Version 3.1 (UNI
3.1), September 1994, Section 5.4.5 Variable Length
Information Elements."
::= { atm2MIBObjects 5 }
atmSigDescrParamEntry OBJECT-TYPE
SYNTAX AtmSigDescrParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table represents a
set of signalling capabilities that can
be applied to a VCL. There is no requirement
for unique entries, except that the index must
be unique."
INDEX { atmSigDescrParamIndex }
::= { atmSigDescrParamTable 1 }
AtmSigDescrParamEntry ::=
SEQUENCE {
atmSigDescrParamIndex
AtmSigDescrParamIndex,
atmSigDescrParamAalType INTEGER,
atmSigDescrParamAalSscsType INTEGER,
atmSigDescrParamBhliType INTEGER,
atmSigDescrParamBhliInfo OCTET STRING,
atmSigDescrParamBbcConnConf INTEGER,
atmSigDescrParamBlliLayer2 INTEGER,
atmSigDescrParamBlliLayer3 INTEGER,
atmSigDescrParamBlliPktSize INTEGER,
atmSigDescrParamBlliSnapId INTEGER,
atmSigDescrParamBlliOuiPid OCTET STRING,
atmSigDescrParamRowStatus RowStatus
}
atmSigDescrParamIndex OBJECT-TYPE
SYNTAX AtmSigDescrParamIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is used by the
atmVclGenSigDescrIndex object in the atmVclGenTable to
identify a row in this table."
::= { atmSigDescrParamEntry 1 }
atmSigDescrParamAalType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- not defined
aal1(2), -- AAL type 1
aal34(3), -- AAL type 3/4
aal5(4), -- AAL type 5
userDefined(5), -- User-Defined AAL
aal2(6) -- AAL type 2
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The AAL type. The value of this object is set to other(1)
when not defined."
DEFVAL { other }
::= { atmSigDescrParamEntry 2 }
atmSigDescrParamAalSscsType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- other, or not used
assured(2), -- Data SSCS based on SSCOP
-- assured operation
nonassured(3), -- Data SSCS based on SSCOP
-- non-assured operation
frameRelay(4), -- frame relay SSCS
null(5) -- null
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The SSCS type used by this entry."
DEFVAL { other }
::= { atmSigDescrParamEntry 3 }
atmSigDescrParamBhliType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- not defined
iso(2), -- ISO
user(3), -- User specific
hiProfile(4), -- Higher layer profile
-- this enum applicable to
-- UNI 3.0 only
vendorSpecific(5) -- Vender specific
-- application identifier
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Broadband high layer type."
DEFVAL { other }
::= { atmSigDescrParamEntry 4 }
atmSigDescrParamBhliInfo OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..8))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Broadband high layer information. When
atmSigDescrParamBhliType is set to iso(2), the value of this
object is a zero length string. When
atmSigDescrParamBhliType is set to user(3), the value of
this object is an octet string with length ranging from 0 to
8. When atmSigDescrParamBhliType is set to hiProfile(4),
the value of this object is a length of 4 octet string
containing user to user profile identifier. When
atmSigDescrParamBhliType is set to vendorSpecific(5), the
value of this object is a length of 7 octet string, where
the most significant 3 octets consist of a globally-
administered OUI, and the least significant 4 octets are the
vender administered application OUI."
DEFVAL { ''H }
::= { atmSigDescrParamEntry 5 }
atmSigDescrParamBbcConnConf OBJECT-TYPE
SYNTAX INTEGER {
ptp(1), -- point-to-point
ptmp(2) -- point-to-multipoint
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Broadband bearer capability user plane connection
configuration parameter."
DEFVAL { ptp }
::= { atmSigDescrParamEntry 6 }
atmSigDescrParamBlliLayer2 OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- not specified
iso1745(2), -- Basic mode ISO 1745
q921(3), -- CCITT Recommendation Q.921
x25linklayer(4), -- CCITT Recommendation X.25
-- Link Layer
x25multilink(5), -- CCITT Recommendation X.25
-- Multilink
lapb(6), -- Extended LAPB; for half
-- duplex operation
hdlcArm(7), -- HDLC ARM (ISO 4335)
hdlcNrm(8), -- HDLC NRM (ISO 4335)
hdlcAbm(9), -- HDLC ABM (ISO 4335)
iso88022(10), -- LAN logical link control
-- (ISO 8802/2)
x75slp(11), -- CCITT Recommendation X.75,
-- single link
-- procedure (SLP)
q922(12), -- CCITT Recommendation Q.922
userDef(13), -- User specified
iso7776(14) -- ISO 7776 DTE-DTE operation
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Broadband low layer information, protocol type of layer
2. The value of this object is other(1) if layer 2 protocol
is not used."
DEFVAL { other }
::= { atmSigDescrParamEntry 7 }
atmSigDescrParamBlliLayer3 OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- not specified
x25pkt(2), -- CCITT Recommendation X.25
-- packet layer
isoiec8208(3), -- ISO/IEC 8208 (X.25 packet
-- level protocol for data
-- terminal equipment)
x223iso8878(4), -- X.223/ISO 8878
isoiec8473(5), -- ISO/IEC 8473 OSI
-- connectionless
-- mode protocol
t70(6), -- CCITT Recommendation T.70
-- minimum
-- network layer
tr9577(7), -- ISO/IEC TR 9577 Protocol
-- Identification in the
-- network layer
userDef(8) -- user specified
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Broadband low layer information, protocol type of layer
3. The value of this object is other(1) if layer 3 protocol
is not used."
DEFVAL { other }
::= { atmSigDescrParamEntry 8 }
atmSigDescrParamBlliPktSize OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- not used
s16(2), -- 16 octets
s32(3), -- 32 octets
s64(4), -- 64 octets
s128(5), -- 128 octets
s256(6), -- 256 octets
s512(7), -- 512 octets
s1024(8), -- 1028 octets
s2048(9), -- 2048 octets
s4096(10) -- 4096 octets
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The default packet size defined in B-LLI."
DEFVAL { other }
::= { atmSigDescrParamEntry 9 }
atmSigDescrParamBlliSnapId OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- not used
true(2), -- SNAP ID is 1
false(3) -- SNAP ID is 0
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The SNAP ID used for Broadband low layer protocol layer 3.
The value of this object is other(1) if
atmSigDescrParamBlliLayer3 is set to other(1)."
DEFVAL { other }
::= { atmSigDescrParamEntry 10 }
atmSigDescrParamBlliOuiPid OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0|5))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The OUI/PID encoding for Broadband low layer protocol layer
3. The value of this object is a zero length string if
atmSigDescrParamBlliLayer3 is set to other(1). When used,
it is always 5 octets with the most significant octet as the
OUI Octet 1 and the least significant octet as the PID Octet
2."
DEFVAL { ''H }
::= { atmSigDescrParamEntry 11 }
atmSigDescrParamRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create and delete rows in the
atmSigDescrParamTable."
::= { atmSigDescrParamEntry 12 }
-- 6. ATM Interface Registered Address Table --
atmIfRegisteredAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfRegisteredAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains a list of ATM addresses that can be used for
calls to and from a given interface by a switch or service. The
ATM addresses are either registered by the endsystem via ILMI or
statically configured. This table does not expose PNNI
reachability information. ILMI registered addresses cannot be
deleted using this table. This table only applies to switches
and network services."
::= { atm2MIBObjects 6 }
atmIfRegisteredAddrEntry OBJECT-TYPE
SYNTAX AtmIfRegisteredAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Interface Registered Address table."
INDEX { ifIndex, atmIfRegAddrAddress }
::= { atmIfRegisteredAddrTable 1}
AtmIfRegisteredAddrEntry ::= SEQUENCE {
atmIfRegAddrAddress AtmAddr,
atmIfRegAddrAddressSource INTEGER,
atmIfRegAddrOrgScope INTEGER,
atmIfRegAddrRowStatus RowStatus
}
atmIfRegAddrAddress OBJECT-TYPE
SYNTAX AtmAddr
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An address registered for a given switch or service interface."
::= { atmIfRegisteredAddrEntry 1}
atmIfRegAddrAddressSource OBJECT-TYPE
SYNTAX INTEGER {
other(1),
static(2),
dynamic(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of address source for a given ATM Address. The value
dynamic(3) is indicated when ILMI is used."
::= { atmIfRegisteredAddrEntry 2}
atmIfRegAddrOrgScope OBJECT-TYPE
SYNTAX INTEGER {
localNetwork(1),
localNetworkPlusOne(2),
localNetworkPlusTwo(3),
siteMinusOne(4),
intraSite(5),
sitePlusOne(6),
organizationMinusOne(7),
intraOrganization(8),
organizationPlusOne(9),
communityMinusOne(10),
intraCommunity(11),
communityPlusOne(12),
regional(13),
interRegional(14),
global(15)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the organizational scope for
the referenced address. The information of the
referenced address shall not be distributed outside
the indicated scope. Refer to Annex 5.3 of ATM
Forum UNI Signalling 4.0 for guidelines regarding
the use of organizational scopes.
This value cannot be configured for ILMI-registered
addresses.
The default values for organizational scope are
localNetwork(1) for ATM group addresses, and
global(15) for individual addresses."
::= { atmIfRegisteredAddrEntry 3}
atmIfRegAddrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create and delete rows in the
atmIfRegisteredAddrTable. Rows created dynamically (e.g., ILMI-
registered addresses) cannot be deleted using this object."
::= { atmIfRegisteredAddrEntry 4}
-- 7. ATM VPI/VCI to Address Mapping Table
atmVclAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVclAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides a mapping between the atmVclTable and
the ATM called party/calling party address. This table can
be used to retrieve the calling party and called party ATM
address pair for a given VCL. Note that there can be more
than one pair of calling party and called party ATM
addresses for a VCL in a point to multi-point call."
::= { atm2MIBObjects 7 }
atmVclAddrEntry OBJECT-TYPE
SYNTAX AtmVclAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table represents a binding between a VCL
and an ATM address associated with this call. This ATM
address can be either the called party address or the
calling party address. There can be more than one pair of
calling/called party ATM addresses associated with the VCL
entry for point to multi-point calls. Objects
atmVclAddrType, and atmVclAddrRowStatus are
required during row creation."
INDEX { ifIndex, atmVclVpi, atmVclVci,
atmVclAddrAddr }
::= { atmVclAddrTable 1 }
AtmVclAddrEntry ::=
SEQUENCE {
atmVclAddrAddr AtmAddr,
atmVclAddrType INTEGER,
atmVclAddrRowStatus RowStatus
}
atmVclAddrAddr OBJECT-TYPE
SYNTAX AtmAddr
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An ATM address on one end of the VCL. For SVCs, the agent
supplies the value of this object at creation time. For PVC
VCL, the manager can supply the value of this object during
or after the PVC VCL creation."
::= { atmVclAddrEntry 1 }
atmVclAddrType OBJECT-TYPE
SYNTAX INTEGER {
callingParty(1),
calledParty(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of ATM Address represented by the object
atmVclAddrAddr. Choices are either the calling party ATM
address or the called party ATM address."
::= { atmVclAddrEntry 2 }
atmVclAddrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create or destroy an
entry from this table. Note that the manager entity
can only destroy the PVC VCLs."
::= { atmVclAddrEntry 3 }
-- 8. ATM Address to VPI/VCI Mapping Table
--
-- This table provides an alternative way to access
-- a row in the atmVclAddrTable by using
-- an ATM address as an index, instead of
-- the ifIndex
atmAddrVclTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmAddrVclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides an alternative way to retrieve the
atmVclTable. This table can be used to retrieve the
indexing to the atmVclTable by an ATM address."
::= { atm2MIBObjects 8 }
atmAddrVclEntry OBJECT-TYPE
SYNTAX AtmAddrVclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table represents an entry in the
atmVclTable of the ATM-MIB by its ATM address. The ATM
address is either the calling or called party ATM address
of the call. Entries in this table are read only.
They show up when entries are created in the
atmVclAddrTable."
REFERENCE
"Tesink, K., Editor, Definitions of Managed Objects
for ATM Management, RFC 2515, Bell Communications
Research, February, 1999."
INDEX { atmVclAddrAddr, atmAddrVclAtmIfIndex,
atmAddrVclVpi, atmAddrVclVci }
::= { atmAddrVclTable 1 }
AtmAddrVclEntry ::=
SEQUENCE {
atmAddrVclAtmIfIndex InterfaceIndex,
atmAddrVclVpi AtmVpIdentifier,
atmAddrVclVci AtmVcIdentifier,
atmAddrVclAddrType INTEGER
}
atmAddrVclAtmIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface index of the ATM interface to which this
VCL pertains. This object combined with the
atmAddrVclVpi and atmAddrVclVci objects serves as an
index to the atmVclTable."
::= { atmAddrVclEntry 1 }
atmAddrVclVpi OBJECT-TYPE
SYNTAX AtmVpIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VPI value of the VCL. This object combined with the
atmAddrVclAtmIfIndex and atmAddrVclVci objects serves as
an index to the atmVclTable."
::= { atmAddrVclEntry 2 }
atmAddrVclVci OBJECT-TYPE
SYNTAX AtmVcIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VCI value of the VCL. This object combined with the
atmAddrVclAtmIfIndex and atmAddrVclVpi objects serves as
an index to the atmVclTable."
::= { atmAddrVclEntry 3 }
atmAddrVclAddrType OBJECT-TYPE
SYNTAX INTEGER {
callingParty(1),
calledParty(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of ATM Address represented by the object
atmVclAddrAddr. Choices are either calling party address
or called party address."
::= { atmAddrVclEntry 4 }
-- 9. ATM VPL Statistics Table
atmVplStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVplStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains all statistics counters per VPL. It is
used to monitor the usage of the VPL in terms of incoming
cells and outgoing cells."
::= { atm2MIBObjects 9 }
atmVplStatEntry OBJECT-TYPE
SYNTAX AtmVplStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table represents a VPL."
INDEX { ifIndex, atmVplVpi }
::= { atmVplStatTable 1 }
AtmVplStatEntry ::=
SEQUENCE {
atmVplStatTotalCellIns Counter32,
atmVplStatClp0CellIns Counter32,
atmVplStatTotalDiscards Counter32,
atmVplStatClp0Discards Counter32,
atmVplStatTotalCellOuts Counter32,
atmVplStatClp0CellOuts Counter32,
atmVplStatClp0Tagged Counter32
}
atmVplStatTotalCellIns OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received by this VPL
including both CLP=0 and CLP=1 cells. The cells are
counted prior to the application of the traffic policing."
::= { atmVplStatEntry 1 }
atmVplStatClp0CellIns OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of valid ATM cells received by this VPL with
CLP=0. The cells are counted prior to the application of
the traffic policing."
::= { atmVplStatEntry 2 }
atmVplStatTotalDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells discarded by the
traffic policing entity. This includes cells originally
received with CLP=0 and CLP=1."
::= { atmVplStatEntry 3 }
atmVplStatClp0Discards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received with CLP=0 and
discarded by the traffic policing entity."
::= { atmVplStatEntry 4 }
atmVplStatTotalCellOuts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted by this
VPL. This includes both CLP=0 and CLP=1 cells."
::= { atmVplStatEntry 5 }
atmVplStatClp0CellOuts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted with CLP=0
by this VPL."
::= { atmVplStatEntry 6 }
atmVplStatClp0Tagged OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells tagged by the traffic
policing entity from CLP=0 to CLP=1."
::= { atmVplStatEntry 7 }
-- 10. ATM Logical Port Configuration Table
atmVplLogicalPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVplLogicalPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates whether the VPL is an ATM Logical Port interface
(ifType=80)."
::= { atm2MIBObjects 10 }
atmVplLogicalPortEntry OBJECT-TYPE
SYNTAX AtmVplLogicalPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry with information about the ATM Logical Port
interface."
AUGMENTS { atmVplEntry }
::= { atmVplLogicalPortTable 1 }
AtmVplLogicalPortEntry ::=
SEQUENCE {
atmVplLogicalPortDef INTEGER,
atmVplLogicalPortIndex InterfaceIndexOrZero
}
atmVplLogicalPortDef OBJECT-TYPE
SYNTAX INTEGER {
notLogicalIf(1),
isLogicalIf(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the VPC at this VPL interface is an ATM
Logical Port interface."
DEFVAL { notLogicalIf }
::= { atmVplLogicalPortEntry 1 }
atmVplLogicalPortIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifTable index of the ATM logical port interface
associated with this VPL. The distinguished value of zero
indicates that the agent has not (yet) assigned such an
ifTable Index. The zero value must be assigned by the agent
if the value of atmVplLogicalPortDef is set to notLogicalIf,
or if the VPL row is not active."
::= { atmVplLogicalPortEntry 2 }
-- 11. ATM VCL Statistics Table
atmVclStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVclStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains all statistics counters per VCL. It is
used to monitor the usage of the VCL in terms of incoming
cells and outgoing cells."
::= { atm2MIBObjects 11 }
atmVclStatEntry OBJECT-TYPE
SYNTAX AtmVclStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table represents a VCL."
INDEX { ifIndex, atmVclVpi, atmVclVci }
::= { atmVclStatTable 1 }
AtmVclStatEntry ::=
SEQUENCE {
atmVclStatTotalCellIns Counter32,
atmVclStatClp0CellIns Counter32,
atmVclStatTotalDiscards Counter32,
atmVclStatClp0Discards Counter32,
atmVclStatTotalCellOuts Counter32,
atmVclStatClp0CellOuts Counter32,
atmVclStatClp0Tagged Counter32
}
atmVclStatTotalCellIns OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received by this VCL
including both CLP=0 and CLP=1 cells. The cells are counted
prior to the application of the traffic policing."
::= { atmVclStatEntry 1 }
atmVclStatClp0CellIns OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of valid ATM cells received by this VCL with
CLP=0. The cells are counted prior to the application of
the traffic policing."
::= { atmVclStatEntry 2 }
atmVclStatTotalDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells discarded by the
traffic policing entity. This includes cells originally
received with CLP=0 and CLP=1."
::= { atmVclStatEntry 3 }
atmVclStatClp0Discards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received with CLP=0
and discarded by the traffic policing entity."
::= { atmVclStatEntry 4 }
atmVclStatTotalCellOuts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted by this
VCL. This includes both CLP=0 and CLP=1 cells."
::= { atmVclStatEntry 5 }
atmVclStatClp0CellOuts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted with CLP=0
by this VCL."
::= { atmVclStatEntry 6 }
atmVclStatClp0Tagged OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells tagged by the traffic
policing entity from CLP=0 to CLP=1."
::= { atmVclStatEntry 7 }
-- 12. ATM AAL5 per-VCC Statistics Table
atmAal5VclStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmAal5VclStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides a collection of objects providing AAL5
configuration and performance statistics of a VCL."
::= { atm2MIBObjects 12 }
atmAal5VclStatEntry OBJECT-TYPE
SYNTAX AtmAal5VclStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table represents an AAL5 VCL, and
is indexed by ifIndex values of AAL5 interfaces and
the associated VPI/VCI values."
INDEX { ifIndex, atmVclVpi, atmVclVci }
::= { atmAal5VclStatTable 1 }
AtmAal5VclStatEntry ::=
SEQUENCE {
atmAal5VclInPkts Counter32,
atmAal5VclOutPkts Counter32,
atmAal5VclInOctets Counter32,
atmAal5VclOutOctets Counter32
}
atmAal5VclInPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of AAL5 CPCS PDUs received on the AAL5 VCC at
the interface identified by the ifIndex."
::= { atmAal5VclStatEntry 1 }
atmAal5VclOutPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of AAL5 CPCS PDUs transmitted on the AAL5 VCC
at the interface identified by the ifIndex."
::= { atmAal5VclStatEntry 2 }
atmAal5VclInOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in AAL5 CPCS PDUs received
on the AAL5 VCC at the interface identified by the ifIndex."
::= { atmAal5VclStatEntry 3 }
atmAal5VclOutOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in AAL5 CPCS PDUs
transmitted on the AAL5 VCC at the interface identified by
the ifIndex."
::= { atmAal5VclStatEntry 4 }
-- 13. ATM VC General Information Table
atmVclGenTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVclGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"General Information for each VC."
::= { atm2MIBObjects 13 }
atmVclGenEntry OBJECT-TYPE
SYNTAX AtmVclGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry with general information about the ATM VC."
AUGMENTS { atmVclEntry }
::= { atmVclGenTable 1 }
AtmVclGenEntry ::=
SEQUENCE {
atmVclGenSigDescrIndex AtmSigDescrParamIndex
}
atmVclGenSigDescrIndex OBJECT-TYPE
SYNTAX AtmSigDescrParamIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the row in the ATM
Signalling Descriptor Parameter Table which applies to this
VCL."
::= { atmVclGenEntry 1 }
-- 14. ATM Interface Configuration Extension Table
atmInterfaceExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmInterfaceExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ATM interface configuration and monitoring
information not defined in the atmInterfaceConfTable from the
ATM-MIB. This includes the type of connection setup procedures,
ILMI information, and information on the VPI/VCI range."
REFERENCE
"Tesink, K., Editor, Definitions of Managed Objects
for ATM Management, RFC 2515, Bell Communications
Research, February, 1999."
::= { atm2MIBObjects 14 }
atmInterfaceExtEntry OBJECT-TYPE
SYNTAX AtmInterfaceExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry extends the atmInterfaceConfEntry defined in the ATM-
MIB. Each entry corresponds to an ATM interface."
REFERENCE
"Tesink, K., Editor, Definitions of Managed Objects
for ATM Management, RFC 2515, Bell Communications
Research, February, 1999."
AUGMENTS { atmInterfaceConfEntry }
::= { atmInterfaceExtTable 1 }
AtmInterfaceExtEntry ::= SEQUENCE {
atmIntfConfigType AtmInterfaceType,
atmIntfActualType AtmInterfaceType,
atmIntfConfigSide INTEGER,
atmIntfActualSide INTEGER,
atmIntfIlmiAdminStatus BITS,
atmIntfIlmiOperStatus BITS,
atmIntfIlmiFsmState INTEGER,
atmIntfIlmiEstablishConPollIntvl Integer32,
atmIntfIlmiCheckConPollIntvl Integer32,
atmIntfIlmiConPollInactFactor Integer32,
atmIntfIlmiPublicPrivateIndctr INTEGER,
atmInterfaceConfMaxSvpcVpi INTEGER,
atmInterfaceCurrentMaxSvpcVpi INTEGER,
atmInterfaceConfMaxSvccVpi INTEGER,
atmInterfaceCurrentMaxSvccVpi INTEGER,
atmInterfaceConfMinSvccVci INTEGER,
atmInterfaceCurrentMinSvccVci INTEGER,
atmIntfSigVccRxTrafficDescrIndex
AtmTrafficDescrParamIndex,
atmIntfSigVccTxTrafficDescrIndex
AtmTrafficDescrParamIndex,
atmIntfPvcFailures Counter32,
atmIntfCurrentlyFailingPVpls Gauge32,
atmIntfCurrentlyFailingPVcls Gauge32,
atmIntfPvcFailuresTrapEnable TruthValue,
atmIntfPvcNotificationInterval INTEGER,
atmIntfLeafSetupFailures Counter32,
atmIntfLeafSetupRequests Counter32 }
atmIntfConfigType OBJECT-TYPE
SYNTAX AtmInterfaceType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of connection setup procedures configured for the ATM
interface. Setting this variable to a value of 'other' is not
allowed."
DEFVAL { autoConfig }
::= { atmInterfaceExtEntry 1 }
atmIntfActualType OBJECT-TYPE
SYNTAX AtmInterfaceType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of connection setup procedures currently being used on
the interface. This may reflect a manually configured value for
the interface type, or may be determined by other means such as
auto-configuration. A value of `autoConfig' indicates that
auto-configuration was requested but has not yet been completed."
::= { atmInterfaceExtEntry 2 }
atmIntfConfigSide OBJECT-TYPE
SYNTAX INTEGER {
other(1),
user(2),
network(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured role of the managed entity as one side of the ATM
interface. This value does not apply when the object
atmIntfConfigType is set to `autoConfig', `atmfPnni1Dot0', or
`atmfBici2Dot0'."
::= { atmInterfaceExtEntry 3 }
atmIntfActualSide OBJECT-TYPE
SYNTAX INTEGER {
other(1),
user(2),
network(3),
symmetric(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current role used by the managed entity to represent one
side of the ATM interface."
::= { atmInterfaceExtEntry 4 }
atmIntfIlmiAdminStatus OBJECT-TYPE
SYNTAX BITS { ilmi(0),
ilmiAddressRegistration(1),
ilmiConnectivity(2),
ilmiPvcPvpMgmt(3),
ilmiSigVccParamNegotiation(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates which components of ILMI are administratively enabled
on this interface. If the 'ilmi' bit is not set, then no ILMI
components are operational. ILMI components other than auto-
configuration that are not represented in the value have their
administrative status determined according to the 'ilmi' bit.
The ILMI auto-configuration component is enabled/disabled by the
atmIntfConfigType object."
::= { atmInterfaceExtEntry 5 }
atmIntfIlmiOperStatus OBJECT-TYPE
SYNTAX BITS { ilmi(0),
ilmiAddressRegistration(1),
ilmiConnectivity(2),
ilmiPvcPvpMgmt(3),
ilmiSigVccParamNegotiation(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates which components of ILMI are operational on this
interface."
::= { atmInterfaceExtEntry 6 }
atmIntfIlmiFsmState OBJECT-TYPE
SYNTAX INTEGER { stopped(1),
linkFailing(2),
establishing(3),
configuring(4),
retrievingNetworkPrefixes(5),
registeringNetworkPrefixes(6),
retrievingAddresses(7),
registeringAddresses(8),
verifying(9) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the state of the ILMI Finite State Machine associated
with this interface."
REFERENCE
"ATM Forum, Integrated Local Management Interface
(ILMI) Specification, Version 4.0, af-ilmi-0065.000,
September 1996, Appendix 1"
::= { atmInterfaceExtEntry 7 }
atmIntfIlmiEstablishConPollIntvl OBJECT-TYPE
SYNTAX Integer32 (1..65535)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time S between successive transmissions of ILMI
messages on this interface for the purpose of detecting
establishment of ILMI connectivity."
REFERENCE
"ATM Forum, Integrated Local Management Interface
(ILMI) Specification, Version 4.0, af-ilmi-0065.000,
September 1996, Section 8.3.1"
DEFVAL { 1 }
::= { atmInterfaceExtEntry 8 }
atmIntfIlmiCheckConPollIntvl OBJECT-TYPE
SYNTAX Integer32 (0..65535)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time T between successive transmissions of ILMI
messages on this interface for the purpose of detecting loss of
ILMI connectivity. The distinguished value zero disables ILMI
connectivity procedures on this interface."
REFERENCE
"ATM Forum, Integrated Local Management Interface
(ILMI) Specification, Version 4.0, af-ilmi-0065.000,
September 1996, Section 8.3.1"
DEFVAL { 5 }
::= { atmInterfaceExtEntry 9 }
atmIntfIlmiConPollInactFactor OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number K of consecutive polls on this interface for which no
ILMI response message is received before ILMI connectivity is
declared lost."
REFERENCE
"ATM Forum, Integrated Local Management Interface
(ILMI) Specification, Version 4.0, af-ilmi-0065.000,
September 1996, Section 8.3.1"
DEFVAL { 4 }
::= { atmInterfaceExtEntry 10 }
atmIntfIlmiPublicPrivateIndctr OBJECT-TYPE
SYNTAX INTEGER {
other(1),
public(2),
private(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies whether this end of the interface is advertised in
ILMI as a device of the `public' or `private' type."
DEFVAL { private }
::= { atmInterfaceExtEntry 11 }
atmInterfaceConfMaxSvpcVpi OBJECT-TYPE
SYNTAX INTEGER (0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum VPI that the signalling stack on the ATM interface
is configured to support for allocation to switched virtual path
connections."
::= { atmInterfaceExtEntry 12 }
atmInterfaceCurrentMaxSvpcVpi OBJECT-TYPE
SYNTAX INTEGER (0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum VPI that the signalling stack on the ATM interface
may currently allocate to switched virtual path connections.
This value is the minimum of atmInterfaceConfMaxSvpcVpi, and the
atmInterfaceMaxSvpcVpi of the interface's UNI/NNI peer.
If the interface does not negotiate with its peer to determine
the maximum VPI that can be allocated to SVPCs on the interface,
then the value of this object must equal
atmInterfaceConfMaxSvpcVpi. "
::= { atmInterfaceExtEntry 13 }
atmInterfaceConfMaxSvccVpi OBJECT-TYPE
SYNTAX INTEGER (0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum VPI that the signalling stack on the ATM interface
is configured to support for allocation to switched virtual
channel connections."
::= { atmInterfaceExtEntry 14 }
atmInterfaceCurrentMaxSvccVpi OBJECT-TYPE
SYNTAX INTEGER (0..4095)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum VPI that the signalling stack on the ATM interface
may currently allocate to switched virtual channel connections.
This value is the minimum of atmInterfaceConfMaxSvccVpi, and the
atmInterfaceConfMaxSvccVpi of the interface's UNI/NNI peer.
If the interface does not negotiate with its peer to determine
the maximum VPI that can be allocated to SVCCs on the interface,
then the value of this object must equal
atmInterfaceConfMaxSvccVpi."
::= { atmInterfaceExtEntry 15 }
atmInterfaceConfMinSvccVci OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum VCI that the signalling stack on the ATM interface
is configured to support for allocation to switched virtual
channel connections."
::= { atmInterfaceExtEntry 16 }
atmInterfaceCurrentMinSvccVci OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum VCI that the signalling stack on the ATM interface
may currently allocate to switched virtual channel connections.
This value is the maximum of atmInterfaceConfMinSvccVci, and the
atmInterfaceConfMinSvccVci of the interface's UNI/NNI peer.
If the interface does not negotiate with its peer to determine
the minimum VCI that can be allocated to SVCCs on the interface,
then the value of this object must equal
atmInterfaceConfMinSvccVci."
::= { atmInterfaceExtEntry 17 }
atmIntfSigVccRxTrafficDescrIndex OBJECT-TYPE
SYNTAX AtmTrafficDescrParamIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the row in the atmTrafficDescrParamTable
used during ILMI auto-configuration to specify the advertised
signalling VCC traffic parameters for the receive direction.
The traffic descriptor resulting from ILMI auto-configuration of
the signalling VCC is indicated in the atmVclTable."
::= { atmInterfaceExtEntry 18 }
atmIntfSigVccTxTrafficDescrIndex OBJECT-TYPE
SYNTAX AtmTrafficDescrParamIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the row in the atmTrafficDescrParamTable
used during ILMI auto-configuration to specify the advertised
signalling VCC traffic parameters for the transmit direction.
The traffic descriptor resulting from ILMI auto-configuration of
the signalling VCC is indicated in the atmVclTable."
::= { atmInterfaceExtEntry 19 }
atmIntfPvcFailures OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the operational status of a PVPL or PVCL on
this interface has gone down."
::= { atmInterfaceExtEntry 20 }
atmIntfCurrentlyFailingPVpls OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of VPLs on this interface for which there is
an active row in the atmVplTable having an atmVplConnKind value
of `pvc' and an atmVplOperStatus with a value other than `up'."
::= { atmInterfaceExtEntry 21 }
atmIntfCurrentlyFailingPVcls OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of VCLs on this interface for which there is
an active row in the atmVclTable having an atmVclConnKind value
of `pvc' and an atmVclOperStatus with a value other than `up'."
::= { atmInterfaceExtEntry 22 }
atmIntfPvcFailuresTrapEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows the generation of traps in response to PVCL or PVPL
failures on this interface."
DEFVAL { false }
::= { atmInterfaceExtEntry 23 }
atmIntfPvcNotificationInterval OBJECT-TYPE
SYNTAX INTEGER (1..3600)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum interval between the sending of
atmIntfPvcFailuresTrap notifications for this interface."
DEFVAL { 30 }
::= { atmInterfaceExtEntry 24 }
atmIntfLeafSetupFailures OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of setup failures. For root, this is the number of
rejected setup requests and for leaf, this is the number of setup
failure received."
::= { atmInterfaceExtEntry 25 }
atmIntfLeafSetupRequests OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of setup requests. For root, this includes both incoming
setup request and root intiated setup requests."
::= { atmInterfaceExtEntry 26 }
-- 15. ATM ILMI Service Registry Table
atmIlmiSrvcRegTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIlmiSrvcRegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains a list of all the ATM network services known
by this device.
The characteristics of these services are made available through
the ILMI, using the ILMI general-purpose service registry MIB.
These services may be made available to all ATM interfaces
(atmIlmiSrvcRegIndex = 0) or to some specific ATM interfaces only
(atmIlmiSrvcRegIndex = ATM interface index)."
::= { atm2MIBObjects 15 }
atmIlmiSrvcRegEntry OBJECT-TYPE
SYNTAX AtmIlmiSrvcRegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a single service provider that is available to
the user-side of an adjacent device through the ILMI.
Implementors need to be aware that if the size of the
atmIlmiSrvcRegServiceID exceeds 112 sub-identifiers then OIDs of
column instances in this table will have more than 128 sub-
identifiers and cannot be accessed using SNMPv1, SNMPv2, or
SNMPv3."
INDEX { atmIlmiSrvcRegIndex,
atmIlmiSrvcRegServiceID,
atmIlmiSrvcRegAddressIndex }
::= { atmIlmiSrvcRegTable 1 }
AtmIlmiSrvcRegEntry ::= SEQUENCE {
atmIlmiSrvcRegIndex InterfaceIndexOrZero,
atmIlmiSrvcRegServiceID OBJECT IDENTIFIER,
atmIlmiSrvcRegAddressIndex INTEGER,
atmIlmiSrvcRegATMAddress AtmAddr,
atmIlmiSrvcRegParm1 OCTET STRING,
atmIlmiSrvcRegRowStatus RowStatus
}
atmIlmiSrvcRegIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM interface where the service defined in this entry can be
made available to an ATM device attached to this interface.
The value of 0 has a special meaning: when an ATM service is
defined in an entry whose atmIlmiSrvcRegIndex is zero, the ATM
service is available to ATM devices connected to any ATM
interface. (default value(s)).
When the user-side of an adjacent device queries the content of
the ILMI service registry MIB (using the ILMI protocol), the
local network-side responds with the ATM services defined in
atmIlmiSrvcRegTable entries, provided that these entries are
indexed by:
- the corresponding ifIndex value (atmIlmiSrvcRegIndex
equal to the ifIndex of the interface to which the
adjacent device is connected) - zero (atmIlmiSrvcRegIndex=0)."
::= { atmIlmiSrvcRegEntry 1 }
atmIlmiSrvcRegServiceID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the service identifier which uniquely identifies the
type of service at the address provided in the table. The object
identifiers for the LAN Emulation Configuration Server (LECS) and
the ATM Name Server (ANS) are defined in the ATM Forum ILMI
Service Registry MIB. The object identifiers for the ATMARP
Server, the Multicast Address Resolution Server (MARS), and the
NHRP Server (NHS) are defined in RFC 2601, RFC 2602, and RFC
2603, respectively."
::= { atmIlmiSrvcRegEntry 2 }
atmIlmiSrvcRegAddressIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer to differentiate multiple rows containing
different ATM addresses for the same service on the same
interface. This number need NOT be the same as the corresponding
ILMI atmfSrvcRegAddressIndex MIB object."
::= { atmIlmiSrvcRegEntry 3 }
atmIlmiSrvcRegATMAddress OBJECT-TYPE
SYNTAX AtmAddr
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the full address of the service. The user-side of the
adjacent device may use this address to establish a connection
with the service."
::= { atmIlmiSrvcRegEntry 4 }
atmIlmiSrvcRegParm1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An octet string used according to the value of
atmIlmiSrvcRegServiceID."
::= { atmIlmiSrvcRegEntry 5 }
atmIlmiSrvcRegRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create or destroy an entry from this
table."
::= { atmIlmiSrvcRegEntry 6 }
-- 16. ILMI Network Prefix Table
atmIlmiNetworkPrefixTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIlmiNetworkPrefixEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table specifying per-interface network prefix(es) supplied by
the network side of the UNI during ILMI address registration.
When no network prefixes are specified for a particular
interface, one or more network prefixes based on the switch
address(es) may be used for ILMI address registration."
::= { atm2MIBObjects 16 }
atmIlmiNetworkPrefixEntry OBJECT-TYPE
SYNTAX AtmIlmiNetworkPrefixEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a single network prefix supplied by the
network side of the UNI during ILMI address registration. Note
that the index variable atmIlmiNetPrefixPrefix is a variable-
length string, and as such the rule for variable-length strings
in section 7.7 of RFC 2578 applies."
INDEX { ifIndex,
atmIlmiNetPrefixPrefix }
::= { atmIlmiNetworkPrefixTable 1 }
AtmIlmiNetworkPrefixEntry ::=
SEQUENCE {
atmIlmiNetPrefixPrefix AtmIlmiNetworkPrefix,
atmIlmiNetPrefixRowStatus RowStatus
}
atmIlmiNetPrefixPrefix OBJECT-TYPE
SYNTAX AtmIlmiNetworkPrefix
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The network prefix specified for use in ILMI address
registration."
::= { atmIlmiNetworkPrefixEntry 1 }
atmIlmiNetPrefixRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used to create, delete, activate and de-activate network
prefixes used in ILMI address registration."
::= { atmIlmiNetworkPrefixEntry 2 }
-- 17. ATM Switch Address Table
atmSwitchAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSwitchAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one or more ATM endsystem addresses on a
per-switch basis. These addresses are used to identify the
switch. When no ILMI network prefixes are configured for certain
interfaces, network prefixes based on the switch address(es) may
be used for ILMI address registration."
::= { atm2MIBObjects 17 }
atmSwitchAddressEntry OBJECT-TYPE
SYNTAX AtmSwitchAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Switch Address table."
INDEX { atmSwitchAddressIndex }
::= { atmSwitchAddressTable 1 }
AtmSwitchAddressEntry ::=
SEQUENCE {
atmSwitchAddressIndex Integer32,
atmSwitchAddressAddress OCTET STRING,
atmSwitchAddressRowStatus RowStatus
}
atmSwitchAddressIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary index used to enumerate the ATM endsystem addresses
for this switch."
::= { atmSwitchAddressEntry 1 }
atmSwitchAddressAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(13|20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An ATM endsystem address or address prefix used to identify this
switch. When no ESI or SEL field is specified, the switch may
generate the ESI and SEL fields automatically to obtain a
complete 20-byte ATM endsystem address."
::= { atmSwitchAddressEntry 2 }
atmSwitchAddressRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used to create, delete, activate, and de-activate addresses used
to identify this switch."
::= { atmSwitchAddressEntry 3 }
-- 18. ATM VP Cross-Connect Extension Table
atmVpCrossConnectXTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpCrossConnectXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per VP Cross-Connect represented in
the atmVpCrossConnectTable."
::= { atm2MIBObjects 18 }
atmVpCrossConnectXEntry OBJECT-TYPE
SYNTAX AtmVpCrossConnectXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular ATM VP Cross-Connect.
Each entry provides an two objects that name the Cross-Connect.
One is assigned by the Service User and the other by the Service
Provider."
AUGMENTS { atmVpCrossConnectEntry }
::= { atmVpCrossConnectXTable 1 }
AtmVpCrossConnectXEntry ::= SEQUENCE {
atmVpCrossConnectUserName SnmpAdminString,
atmVpCrossConnectProviderName SnmpAdminString
}
atmVpCrossConnectUserName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is a service user assigned textual representation of a VPC
PVC."
::= { atmVpCrossConnectXEntry 1 }
atmVpCrossConnectProviderName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a system supplied textual representation of VPC PVC. It
is assigned by the service provider."
::= { atmVpCrossConnectXEntry 2 }
-- 19. ATM VC Cross-Connect Extension Table
atmVcCrossConnectXTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcCrossConnectXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per VC Cross-Connect represented in
the atmVcCrossConnectTable."
::= { atm2MIBObjects 19 }
atmVcCrossConnectXEntry OBJECT-TYPE
SYNTAX AtmVcCrossConnectXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular ATM VC Cross-Connect.
Each entry provides an two objects that name the Cross-Connect.
One is assigned by the Service User and the other by the Service
Provider."
AUGMENTS { atmVcCrossConnectEntry }
::= { atmVcCrossConnectXTable 1 }
AtmVcCrossConnectXEntry ::= SEQUENCE {
atmVcCrossConnectUserName SnmpAdminString,
atmVcCrossConnectProviderName SnmpAdminString
}
atmVcCrossConnectUserName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is a service user assigned textual representation of a VCC
PVC."
::= { atmVcCrossConnectXEntry 1 }
atmVcCrossConnectProviderName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a system supplied textual representation of VCC PVC. It
is assigned by the service provider."
::= { atmVcCrossConnectXEntry 2 }
-- 20. Currently Failing PVPL Table
atmCurrentlyFailingPVplTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCurrentlyFailingPVplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table indicating all VPLs for which there is an active row in
the atmVplTable having an atmVplConnKind value of `pvc' and an
atmVplOperStatus with a value other than `up'."
::= { atm2MIBObjects 20 }
atmCurrentlyFailingPVplEntry OBJECT-TYPE
SYNTAX AtmCurrentlyFailingPVplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table represents a VPL for which the
atmVplRowStatus is `active', the atmVplConnKind is `pvc', and the
atmVplOperStatus is other than `up'."
INDEX { ifIndex, atmVplVpi }
::= { atmCurrentlyFailingPVplTable 1 }
AtmCurrentlyFailingPVplEntry ::=
SEQUENCE {
atmCurrentlyFailingPVplTimeStamp TimeStamp
}
atmCurrentlyFailingPVplTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time at which this PVPL began to fail."
::= { atmCurrentlyFailingPVplEntry 1 }
-- 21. Currently Failing PVCL Table
atmCurrentlyFailingPVclTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCurrentlyFailingPVclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table indicating all VCLs for which there is an active row in
the atmVclTable having an atmVclConnKind value of `pvc' and an
atmVclOperStatus with a value other than `up'."
::= { atm2MIBObjects 21 }
atmCurrentlyFailingPVclEntry OBJECT-TYPE
SYNTAX AtmCurrentlyFailingPVclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table represents a VCL for which the
atmVclRowStatus is `active', the atmVclConnKind is `pvc', and the
atmVclOperStatus is other than `up'."
INDEX { ifIndex, atmVclVpi, atmVclVci }
::= { atmCurrentlyFailingPVclTable 1 }
AtmCurrentlyFailingPVclEntry ::=
SEQUENCE {
atmCurrentlyFailingPVclTimeStamp TimeStamp
}
atmCurrentlyFailingPVclTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time at which this PVCL began to fail."
::= { atmCurrentlyFailingPVclEntry 1 }
-- ATM PVC Traps
atmPvcTraps OBJECT IDENTIFIER ::= { atm2MIBTraps 1 }
atmPvcTrapsPrefix OBJECT IDENTIFIER ::= { atmPvcTraps 0 }
atmIntfPvcFailuresTrap NOTIFICATION-TYPE
OBJECTS { ifIndex, atmIntfPvcFailures,
atmIntfCurrentlyFailingPVpls,
atmIntfCurrentlyFailingPVcls }
STATUS current
DESCRIPTION
"A notification indicating that one or more PVPLs or PVCLs on
this interface has failed since the last atmPvcFailuresTrap was
sent. If this trap has not been sent for the last
atmIntfPvcNotificationInterval, then it will be sent on the next
increment of atmIntfPvcFailures."
::= { atmPvcTrapsPrefix 1 }
-- Conformance Information
atm2MIBConformance OBJECT IDENTIFIER ::= {atm2MIB 3}
atm2MIBGroups OBJECT IDENTIFIER ::= {atm2MIBConformance 1}
atm2MIBCompliances OBJECT IDENTIFIER ::= {atm2MIBConformance 2}
-- Compliance Statements
atm2MIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which represent ATM
interfaces. The compliance statements are used to determine
if a particular group or object applies to hosts,
networks/switches, or both. The Common group is defined as
applicable to all three."
MODULE -- this module
MANDATORY-GROUPS { atmCommonGroup }
-- Objects in the ATM Switch/Service/Host Group
GROUP atmCommonStatsGroup
DESCRIPTION
"This group is mandatory for systems that are supporting
per-VPC or per-VCC counters."
OBJECT atmVplLogicalPortDef
MIN-ACCESS read-only
DESCRIPTION
"This object is mandatory for systems support ATM Logical
Port interfaces."
OBJECT atmIntfSigVccRxTrafficDescrIndex
DESCRIPTION
"This object is mandatory for systems that support negotiation
of signalling VCC traffic parameters through ILMI."
OBJECT atmIntfSigVccTxTrafficDescrIndex
DESCRIPTION
"This object is mandatory for systems that support negotiation
of signalling VCC traffic parameters through ILMI."
OBJECT atmCurrentlyFailingPVplTimeStamp
DESCRIPTION
"This object is optional."
OBJECT atmCurrentlyFailingPVclTimeStamp
DESCRIPTION
"This object is optional."
OBJECT atmIntfLeafSetupFailures
DESCRIPTION
"This object is optional."
OBJECT atmIntfLeafSetupRequests
DESCRIPTION
"This object is optional."
-- Objects in the ATM Switch/Service Group
GROUP atmSwitchServcGroup
DESCRIPTION
"This group is mandatory for a Switch/Service that implements
ATM interfaces."
OBJECT atmIfRegAddrRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the six
enumerated values for the RowStatus textual convention need
be supported, specifically: active(1)."
OBJECT atmSvcVpCrossConnectRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the six
enumerated values for the RowStatus textual convention need
be supported, specifically: active(1)"
OBJECT atmSvcVcCrossConnectRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the six
enumerated values for the RowStatus textual convention need
be supported, specifically: active(1)"
-- Objects in the ATM Switch/Service Signalling Group
GROUP atmSwitchServcSigGroup
DESCRIPTION
"This group's write access is not required."
-- Objects in the ATM Switch/Service Notifications Group
GROUP atmSwitchServcNotifGroup
DESCRIPTION
"This group is optional for systems implementing support for
an ATM Switch or an ATM Network Service."
-- Objects in the ATM Switch Group
GROUP atmSwitchGroup
DESCRIPTION
"This group is optional for a switch that implements ATM
interfaces."
-- Objects in the ATM Service Group
GROUP atmServcGroup
DESCRIPTION
"This group is mandatory for systems implementing support for
an ATM Network Service."
-- Objects in the ATM Host Group
GROUP atmHostGroup
DESCRIPTION
"This group is mandatory for a Host that implements ATM
interfaces."
OBJECT atmVclAddrType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT atmVclAddrRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the six
enumerated values for the RowStatus textual convention need
be supported, specifically: active(1)."
-- ATM Host Sig Descriptor Parameter Group
GROUP atmHostSigDescrGroup
DESCRIPTION
"This group is mandatory for a Host that implements ATM
interfaces. Write access is not required for this group."
::= { atm2MIBCompliances 1 }
-- **********************************************
-- Units of Conformance
-- Mandatory for ATM hosts and switch/service providers
atmCommonGroup OBJECT-GROUP
OBJECTS {
atmSigSSCOPConEvents,
atmSigSSCOPErrdPdus,
atmSigDetectSetupAttempts,
atmSigEmitSetupAttempts,
atmSigDetectUnavailRoutes,
atmSigEmitUnavailRoutes,
atmSigDetectUnavailResrcs,
atmSigEmitUnavailResrcs,
atmSigDetectCldPtyEvents,
atmSigEmitCldPtyEvents,
atmSigDetectMsgErrors,
atmSigEmitMsgErrors,
atmSigDetectClgPtyEvents,
atmSigEmitClgPtyEvents,
atmSigDetectTimerExpireds,
atmSigEmitTimerExpireds,
atmSigDetectRestarts,
atmSigEmitRestarts,
atmSigInEstabls,
atmSigOutEstabls,
atmVplLogicalPortDef,
atmVplLogicalPortIndex,
atmInterfaceConfMaxSvpcVpi,
atmInterfaceCurrentMaxSvpcVpi,
atmInterfaceConfMaxSvccVpi,
atmInterfaceCurrentMaxSvccVpi,
atmInterfaceConfMinSvccVci,
atmInterfaceCurrentMinSvccVci,
atmIntfSigVccRxTrafficDescrIndex,
atmIntfSigVccTxTrafficDescrIndex,
atmIntfPvcFailures,
atmIntfCurrentlyFailingPVpls,
atmIntfCurrentlyFailingPVcls,
atmIntfPvcNotificationInterval,
atmIntfPvcFailuresTrapEnable,
atmIntfLeafSetupFailures,
atmIntfLeafSetupRequests,
atmIntfConfigType,
atmIntfActualType,
atmIntfConfigSide,
atmIntfActualSide,
atmIntfIlmiAdminStatus,
atmIntfIlmiOperStatus,
atmIntfIlmiFsmState,
atmIntfIlmiEstablishConPollIntvl,
atmIntfIlmiCheckConPollIntvl,
atmIntfIlmiConPollInactFactor,
atmIntfIlmiPublicPrivateIndctr,
atmCurrentlyFailingPVplTimeStamp,
atmCurrentlyFailingPVclTimeStamp
}
STATUS current
DESCRIPTION
"A collection of objects providing information
for a Switch/Service/Host that implements
ATM interfaces."
::= { atm2MIBGroups 1 }
atmCommonStatsGroup OBJECT-GROUP
OBJECTS {
atmVclStatTotalCellIns,
atmVclStatClp0CellIns,
atmVclStatTotalDiscards,
atmVclStatClp0Discards,
atmVclStatTotalCellOuts,
atmVclStatClp0CellOuts,
atmVclStatClp0Tagged,
atmVplStatTotalCellIns,
atmVplStatClp0CellIns,
atmVplStatTotalDiscards,
atmVplStatClp0Discards,
atmVplStatTotalCellOuts,
atmVplStatClp0CellOuts,
atmVplStatClp0Tagged
}
STATUS current
DESCRIPTION
"A collection of objects providing information
for a Switch/Service/Host that implements
ATM VCL and VPL Statistics"
::= { atm2MIBGroups 2 }
atmSwitchServcGroup OBJECT-GROUP
OBJECTS {
atmIlmiSrvcRegATMAddress,
atmIlmiSrvcRegParm1,
atmIlmiSrvcRegRowStatus,
atmIlmiNetPrefixRowStatus,
atmSvcVpCrossConnectCreationTime,
atmSvcVpCrossConnectRowStatus,
atmSvcVcCrossConnectCreationTime,
atmSvcVcCrossConnectRowStatus,
atmIfRegAddrAddressSource,
atmIfRegAddrOrgScope,
atmIfRegAddrRowStatus}
STATUS current
DESCRIPTION
"A collection of objects providing information
for a Switch/Service that implements ATM interfaces."
::= { atm2MIBGroups 3 }
atmSwitchServcSigGroup OBJECT-GROUP
OBJECTS {
atmSigSupportClgPtyNumDel,
atmSigSupportClgPtySubAddr,
atmSigSupportCldPtySubAddr,
atmSigSupportHiLyrInfo,
atmSigSupportLoLyrInfo,
atmSigSupportBlliRepeatInd,
atmSigSupportAALInfo,
atmSigSupportPrefCarrier}
STATUS current
DESCRIPTION
"A collection of objects providing information
for a Switch/Service that implements ATM signalling."
::= { atm2MIBGroups 4 }
atmSwitchServcNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS { atmIntfPvcFailuresTrap }
STATUS current
DESCRIPTION
"A collection of notifications providing information
for a Switch/Service that implements ATM interfaces."
::= { atm2MIBGroups 5 }
atmSwitchGroup OBJECT-GROUP
OBJECTS {
atmSwitchAddressAddress,
atmSwitchAddressRowStatus }
STATUS current
DESCRIPTION
"A collection of objects providing information
for an ATM switch."
::= { atm2MIBGroups 6 }
atmServcGroup OBJECT-GROUP
OBJECTS {
atmVpCrossConnectUserName,
atmVpCrossConnectProviderName,
atmVcCrossConnectUserName,
atmVcCrossConnectProviderName }
STATUS current
DESCRIPTION
"A collection of objects providing information
for an ATM Network Service."
::= { atm2MIBGroups 7 }
atmHostGroup OBJECT-GROUP
OBJECTS {
atmAal5VclInPkts,
atmAal5VclOutPkts,
atmAal5VclInOctets,
atmAal5VclOutOctets,
atmVclAddrType,
atmVclAddrRowStatus,
atmAddrVclAddrType,
atmVclGenSigDescrIndex}
STATUS current
DESCRIPTION
"A collection of objects providing information
for a Host that implements ATM interfaces."
::= { atm2MIBGroups 8 }
atmHostSigDescrGroup OBJECT-GROUP
OBJECTS {
atmSigDescrParamAalType,
atmSigDescrParamAalSscsType,
atmSigDescrParamBhliType,
atmSigDescrParamBhliInfo,
atmSigDescrParamBbcConnConf,
atmSigDescrParamBlliLayer2,
atmSigDescrParamBlliLayer3,
atmSigDescrParamBlliPktSize,
atmSigDescrParamBlliSnapId,
atmSigDescrParamBlliOuiPid,
atmSigDescrParamRowStatus}
STATUS current
DESCRIPTION
"A collection of objects providing information
for a Host that implements ATM interfaces."
::= { atm2MIBGroups 9 }
END