-- Title: Lenovo XClarity Controller MIB
--
-- Version: 1.1.1
--
-- Release Date: 2019.09.11
--
-- Description: This MIB defines MIB objects that make system instrumentation
-- data available to SNMP management applications.
--
-- Copyright (c) 2016 Lenovo Corp.
-- All Rights Reserved.
--
--
-- OID Format Legend:
-- <a> = attribute ID
-- <i> = index ID
--
---------------------------------------------------------------------------
-- Revisions:
-- First official version, 2017/6/26
-- Remove several unuseful objects, 2017/7/19
-- Update SNMP Agent Community nodes to enable SNMPv1 TRAP, 2017/9/8
-- Using input and output instead of AC and DC to reflect the correct PSU types, 2017/9/19
-- Correct ReadCallHomeExclusionEventEntry::= syntax error, 2017/11/29
-- Add several attributes for raidDriveTable, 2018/2/5
-- remove three unuseful objects description, 2018/6/22
-- Add systemAepDIMMVpdTable to dispaly the AEP DIMM information, 2018/09/20
-- Add one attribute for systemMemoryVpdTable, 2018/12/11
-- Add some notes about the object systemComponentLevelVpdTrackingTable, 2019/08/06
-- Increase Destinguished Name to 300 Characters, 2019/09/11
-- Update the "systemState" description, 2020/2/17
-- Correct the "radiDriveSecured" to be "raidDriveSecured", 2020/06/23
---------------------------------------------------------------------------
LENOVO-XCC-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE FROM RFC-1212
enterprises FROM RFC1155-SMI
DisplayString FROM RFC1213-MIB
IpAddress FROM RFC1155-SMI
Gauge FROM RFC1155-SMI
-- TEXTUAL-CONVENTION FROM SNMPv2-TC
TRAP-TYPE FROM RFC-1215
InetAddressIPv6 FROM INET-ADDRESS-MIB
lenovoServerMibs FROM LENOVO-SMI-MIB;
EntryStatus ::= INTEGER
{ valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
-- The status of a table entry.
--
-- Setting this object to the value invalid(4) has the
-- effect of invalidating the corresponding entry.
-- That is, it effectively disassociates the mapping
-- identified with said entry.
-- It is an implementation-specific matter as to whether
-- the agent removes an invalidated entry from the table.
-- Accordingly, management stations must be prepared to
-- receive tabular information from agents that corresponds
-- to entries currently not in use. Proper
-- interpretation of such entries requires examination
-- of the relevant EntryStatus object.
--
-- An existing instance of this object cannot be set to
-- createRequest(2). This object may only be set to
-- createRequest(2) when this instance is created. When
-- this object is created, the agent may wish to create
-- supplemental object instances to complete a conceptual
-- row in this table. Immediately after completing the
-- create operation, the agent must set this object to
-- underCreation(3).
--
-- Entries shall exist in the underCreation(3) state until
-- the management station is finished configuring the
-- entry and sets this object to valid(1) or aborts,
-- setting this object to invalid(4). If the agent
-- determines that an entry has been in the
-- underCreation(3) state for an abnormally long time,
-- it may decide that the management station has
-- crashed. If the agent makes this decision,
-- it may set this object to invalid(4) to reclaim the
-- entry. A prudent agent will understand that the
-- management station may need to wait for human input
-- and will allow for that possibility in its
-- determination of this abnormally long period.
lenovoXCCMIB MODULE-IDENTITY
LAST-UPDATED "201707190000Z"
ORGANIZATION "Lenovo Group Ltd."
CONTACT-INFO
"Lenovo
Postal: 1009 Think Place
Morrisville, NC 27560
USA
Tel: +1 (919) 968-4465
E-mail: snmp@lenovo.com"
DESCRIPTION
"This MIB is to be used to provide monitoring information support for Lenovo XClarity Controller (XCC)"
REVISION "201707190000Z"
DESCRIPTION
"Initial version."
::= { lenovoServerMibs 1 }
-- ***************************************************************************
-- Start: Define groups of objects within the LenovoRemoteSupSnmpMIB
-- ***************************************************************************
--This group of objects provides the various environmental monitors for the
-- local system and the XCC
monitors OBJECT IDENTIFIER ::= { lenovoXCCMIB 1 }
--This group of objects provides the error log objects for the XCC
errorLogs OBJECT IDENTIFIER ::= { lenovoXCCMIB 2 }
--This group of objects provides configuration functions for the XCC
configureSP OBJECT IDENTIFIER ::= { lenovoXCCMIB 3 }
--This group of objects provides configuration functions for the system(server)
generalSystemSettings OBJECT IDENTIFIER ::= { lenovoXCCMIB 4 }
--This group of objects provides configuration functions for system power
systemPower OBJECT IDENTIFIER ::= { lenovoXCCMIB 5 }
--This group of objects provides functions Service Advisor
serviceAdvisor OBJECT IDENTIFIER ::= { lenovoXCCMIB 8 }
-- Netfinity SP, node for XCC alert MIB
supportProcessor OBJECT IDENTIFIER ::= { lenovoXCCMIB 158 }
-- ****************************************************************************
-- Monitors
-- ****************************************************************************
-- ************************************************************************
-- Temperature
-- ************************************************************************
temperature OBJECT IDENTIFIER ::= { monitors 1 }
tempNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The present number of rows in the temperature table."
::= { temperature 1 }
tempTable OBJECT-TYPE
SYNTAX SEQUENCE OF TempEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This table contains temperature measurement information."
::= { temperature 2 }
tempEntry OBJECT-TYPE
SYNTAX TempEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Each row contains parameters related to a temperature measurement channel."
INDEX { tempIndex }
::= { tempTable 1 }
TempEntry ::=
SEQUENCE {
tempIndex INTEGER,
tempDescr DisplayString,
tempReading DisplayString,
tempNominalReading DisplayString,
tempNonRecovLimitHigh DisplayString,
tempCritLimitHigh DisplayString,
tempNonCritLimitHigh DisplayString,
tempNonRecovLimitLow DisplayString,
tempCritLimitLow DisplayString,
tempNonCritLimitLow DisplayString,
tempHealthStatus DisplayString
}
tempIndex OBJECT-TYPE
SYNTAX INTEGER (1..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular
temperature measurement channel."
::= { tempEntry 1 }
tempDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A description of the temperature measurement
channel."
::= { tempEntry 2 }
tempReading OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Degrees Celsius"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The measured temperature."
::= { tempEntry 3 }
tempNominalReading OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Degrees Celsius"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The nominal temperature, if available."
::= { tempEntry 4 }
tempNonRecovLimitHigh OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Degrees Celsius"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The non-recoverable limit for the measured temperature. If
the measured value rises above this limit a trap is sent."
::= { tempEntry 5}
tempCritLimitHigh OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Degrees Celsius"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The critical limit for the measured temperature. If
the measured value rises above this limit a trap is sent."
::= { tempEntry 6}
tempNonCritLimitHigh OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Degrees Celsius"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The non-critical limit for the measured temperature. If
the measured value rises above this limit a trap is sent."
::= { tempEntry 7}
tempNonRecovLimitLow OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Degrees Celsius"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The non-recoverable limit for the measured temperature. If
the measured value falls below this limit a trap is sent."
::= { tempEntry 8}
tempCritLimitLow OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Degrees Celsius"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The critical limit for the measured temperature. If
the measured value falls below this limit a trap is sent."
::= { tempEntry 9}
tempNonCritLimitLow OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Degrees Celsius"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The non-critical limit for the measured temperature. If
the measured value falls below this limit a trap is sent."
::= { tempEntry 10}
tempHealthStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A description of the temperature component status."
::= { tempEntry 11 }
-- ************************************************************************
-- Voltages
-- ************************************************************************
voltage OBJECT IDENTIFIER ::= { monitors 2 }
--------------------------------------------------------------------------------
voltNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The present number of rows in the voltage table."
::= { voltage 1 }
voltTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoltEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This table contains voltage measurement information."
::= { voltage 2 }
voltEntry OBJECT-TYPE
SYNTAX VoltEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Each row contains parameters related to a
voltage measurement channel."
INDEX { voltIndex }
::= { voltTable 1 }
VoltEntry ::=
SEQUENCE {
voltIndex INTEGER,
voltDescr DisplayString,
voltReading DisplayString,
voltNominalReading DisplayString,
voltNonRecovLimitHigh DisplayString,
voltCritLimitHigh DisplayString,
voltNonCritLimitHigh DisplayString,
voltNonRecovLimitLow DisplayString,
voltCritLimitLow DisplayString,
voltNonCritLimitLow DisplayString,
voltHealthStatus DisplayString
}
voltIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular
voltage measurement channel."
::= { voltEntry 1 }
voltDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A description of the voltage measurement channel."
::= { voltEntry 2 }
voltReading OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Millivolts"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The measured voltage."
::= { voltEntry 3 }
voltNominalReading OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Millivolts"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The nominal voltage, if available."
::= { voltEntry 4 }
voltNonRecovLimitHigh OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Millivolts"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The high non-recoverable limit for the measured voltage. If the
measured value falls above this limit a trap is sent."
::= { voltEntry 5 }
voltCritLimitHigh OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Millivolts"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The high critical limit for the measured voltage. If the
measured value rises above this limit a trap is sent."
::= { voltEntry 6 }
voltNonCritLimitHigh OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Millivolts"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The high non-critical limit for the measured voltage. If the
measured value rises above this limit a trap is sent."
::= { voltEntry 7 }
voltNonRecovLimitLow OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Millivolts"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The low non-recoverable limit for the measured voltage. If the
measured value falls below this limit a trap is sent."
::= { voltEntry 8 }
voltCritLimitLow OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Millivolts"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The low critical limit for the measured voltage. If the
measured value falls below this limit a trap is sent."
::= { voltEntry 9 }
voltNonCritLimitLow OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
UNITS "Millivolts"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The low non-critical limit for the measured voltage. If the
measured value falls below this limit a trap is sent."
::= { voltEntry 10 }
voltHealthStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A description of the voltage component status."
::= { voltEntry 11 }
-- ************************************************************************
-- Fans
-- ************************************************************************
fans OBJECT IDENTIFIER ::= { monitors 3 }
fanNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The present number of rows in the fan table."
::= { fans 1 }
fanTable OBJECT-TYPE
SYNTAX SEQUENCE OF FanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This table contains fan information."
::= { fans 2 }
fanEntry OBJECT-TYPE
SYNTAX FanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Each row contains parameters related to a fan."
INDEX { fanIndex }
::= { fanTable 1 }
FanEntry ::=
SEQUENCE {
fanIndex INTEGER (1..100),
fanDescr DisplayString,
fanSpeed OCTET STRING,
fanNonRecovLimitHigh Gauge,
fanCritLimitHigh Gauge,
fanNonCritLimitHigh Gauge,
fanNonRecovLimitLow Gauge,
fanCritLimitLow Gauge,
fanNonCritLimitLow Gauge,
fanHealthStatus DisplayString
}
fanIndex OBJECT-TYPE
SYNTAX INTEGER (1..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular fan."
::= { fanEntry 1 }
fanDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A description of the fan measurement channel."
::= { fanEntry 2 }
fanSpeed OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Fan speed expressed in percent(%) of maximum RPM.
An octet string expressed as 'ddd% of maximum' where:
d is a decimal digit or blank space for a leading zero.
If the fan is determined not to be running or
the fan speed cannot be determined, the string will
indicate 'Offline'."
::= { fanEntry 3 }
fanNonRecovLimitHigh OBJECT-TYPE
SYNTAX Gauge
UNITS "RPM"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The high non-recoverable limit for the measured fan. If the
measured value falls above this limit a trap is sent."
::= { fanEntry 4 }
fanCritLimitHigh OBJECT-TYPE
SYNTAX Gauge
UNITS "RPM"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The high critical limit for the measured fan. If the
measured value rises above this limit a trap is sent."
::= { fanEntry 5 }
fanNonCritLimitHigh OBJECT-TYPE
SYNTAX Gauge
UNITS "RPM"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The high non-critical limit for the measured fan. If the
measured value rises above this limit a trap is sent."
::= { fanEntry 6 }
fanNonRecovLimitLow OBJECT-TYPE
SYNTAX Gauge
UNITS "RPM"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The low non-recoverable limit for the measured fan. If the
measured value falls below this limit a trap is sent."
::= { fanEntry 7 }
fanCritLimitLow OBJECT-TYPE
SYNTAX Gauge
UNITS "RPM"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The low critical limit for the measured fan. If the
measured value falls below this limit a trap is sent."
::= { fanEntry 8 }
fanNonCritLimitLow OBJECT-TYPE
SYNTAX Gauge
UNITS "RPM"
ACCESS read-only
STATUS mandatory
DESCRIPTION "The low non-critical limit for the measured fan. If the
measured value falls below this limit a trap is sent."
::= { fanEntry 9 }
fanHealthStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A description of the fan component status."
::= { fanEntry 10 }
-- ************************************************************************
-- System Health
-- ************************************************************************
systemHealth OBJECT IDENTIFIER ::= { monitors 4 }
-- ***********************************************************************
-- System Health Status
-- ***********************************************************************
systemHealthStat OBJECT-TYPE
SYNTAX INTEGER {
nonRecoverable(0),
critical(2),
nonCritical(4),
normal(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates status of system health for the
system in which the XCC resides.
Value of 'nonRecoverable' indicates a severe error has occurred
and the system may not be functioning. A value of
'critical' indicates that a error has occurred but
the system is currently functioning properly. A value of
'nonCritical' indicates that a condition has occurred
that may change the state of the system in the future but currently
the system is working properly. A value of
'normal' indicates that the system is operating normally."
::= { systemHealth 1 }
-- ***********************************************************************
-- System Health Summary
-- ***********************************************************************
systemHealthSummaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemHealthSummaryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of System Health summary. Contains more detailed
information about the reasons for the overall system
health status."
::= { systemHealth 2 }
systemHealthSummaryEntry OBJECT-TYPE
SYNTAX SystemHealthSummaryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System Health Summary entry"
INDEX { systemHealthSummaryIndex }
::= { systemHealthSummaryTable 1 }
SystemHealthSummaryEntry ::= SEQUENCE {
systemHealthSummaryIndex INTEGER,
systemHealthSummarySeverity OCTET STRING,
systemHealthSummaryDescription OCTET STRING
}
systemHealthSummaryIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System health summary index."
::= { systemHealthSummaryEntry 1 }
systemHealthSummarySeverity OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System health summary severity."
::= { systemHealthSummaryEntry 2 }
systemHealthSummaryDescription OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System health summary description."
::= { systemHealthSummaryEntry 3 }
-- ***********************************************************************
-- Vital Product Data(VPD) information
-- ***********************************************************************
vpdInformation OBJECT IDENTIFIER ::= { monitors 5 }
-- ***********************************************************************
-- XCC VPD
-- ***********************************************************************
xccVpdTable OBJECT-TYPE
SYNTAX SEQUENCE OF XCCVpdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of XCC VPD."
::= { vpdInformation 1 }
xccVpdEntry OBJECT-TYPE
SYNTAX XCCVpdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"iMBC VPD entry."
INDEX { xccVpdIndex }
::= { xccVpdTable 1 }
XCCVpdEntry ::= SEQUENCE {
xccVpdIndex INTEGER,
xccVpdType OCTET STRING,
xccVpdVersionString OCTET STRING,
xccVpdReleaseDate OCTET STRING
}
xccVpdIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"XCC VPD index."
::= { xccVpdEntry 1 }
xccVpdType OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"XCC VPD Type. Indicates either Bios or Diag or spFimware VPD"
::= { xccVpdEntry 2 }
xccVpdVersionString OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"XCC VPD Version Number of the software(Bios/Diag/spFirmware).
For XCC the string contains both the Build ID and the Version
Number, for example, like '1AOO3A v1.0.1'. "
::= { xccVpdEntry 3 }
xccVpdReleaseDate OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"XCC VPD Release Date of when the software(Bios/Diag/spFirmware) was released."
::= { xccVpdEntry 4 }
-- ***********************************************************************
-- Machine Level VPD
-- ***********************************************************************
machineVpd OBJECT IDENTIFIER ::= { vpdInformation 2 }
machineLevelVpd OBJECT IDENTIFIER ::= { machineVpd 1 }
machineLevelVpdMachineType OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Machine type VPD information."
::= { machineLevelVpd 1 }
machineLevelVpdMachineModel OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Machine model VPD information."
::= { machineLevelVpd 2 }
machineLevelSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Machine serial number VPD information."
::= { machineLevelVpd 3 }
machineLevelUUID OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Machine UUID(Universal Unique ID information)."
::= { machineLevelVpd 4 }
machineLevelProductName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Machine Product Name (e.g. System x3650 M2)."
::= { machineLevelVpd 5 }
-- ***********************************************************************
-- System Component Level VPD
-- ***********************************************************************
systemComponentLevelVpdTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemComponentLevelVpdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of the system component hardware VPD information. View as a
table and not as individual entries for consistent results."
::= { vpdInformation 17 }
systemComponentLevelVpdEntry OBJECT-TYPE
SYNTAX SystemComponentLevelVpdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System component hardware VPD entry. View as a table and not as
individual entries for consistent results."
INDEX { componentLevelVpdIndex }
::= { systemComponentLevelVpdTable 1 }
SystemComponentLevelVpdEntry ::= SEQUENCE {
componentLevelVpdIndex INTEGER,
componentLevelVpdFruNumber OCTET STRING,
componentLevelVpdFruName OCTET STRING,
componentLevelVpdSerialNumber OCTET STRING,
componentLevelVpdManufacturingId OCTET STRING
}
componentLevelVpdIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD index. View as a table and not as individual
entries for consistent results."
::= { systemComponentLevelVpdEntry 1 }
componentLevelVpdFruNumber OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD FRU number. View as a table and not as
individual entries for consistent results."
::= { systemComponentLevelVpdEntry 2 }
componentLevelVpdFruName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD FRU name. View as a table and not as
individual entries for consistent results."
::= { systemComponentLevelVpdEntry 3 }
componentLevelVpdSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD serial number. View as a table and not as
individual entries for consistent results."
::= { systemComponentLevelVpdEntry 4 }
componentLevelVpdManufacturingId OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD manufacturing ID. View as a table and not as
individual entries for consistent results."
::= { systemComponentLevelVpdEntry 5 }
-- ***********************************************************************
-- System Component Level VPD Tracking log
-- ***********************************************************************
systemComponentLevelVpdTrackingTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemComponentLevelVpdTrackingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of system component hardware VPD tracking activity log. The activity
log types depend on ipmifru information in the server but exclude DIMM infromation.
View as a table and not as individual entries for consistent results."
::= { vpdInformation 18 }
systemComponentLevelVpdTrackingEntry OBJECT-TYPE
SYNTAX SystemComponentLevelVpdTrackingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System component hardware VPD tracking activity log entry. View as a
table and not as individual entries for consistent results."
INDEX { componentLevelVpdTrackingIndex }
::= { systemComponentLevelVpdTrackingTable 1 }
SystemComponentLevelVpdTrackingEntry ::= SEQUENCE {
componentLevelVpdTrackingIndex INTEGER,
componentLevelVpdTrackingFruNumber OCTET STRING,
componentLevelVpdTrackingFruName OCTET STRING,
componentLevelVpdTrackingSerialNumber OCTET STRING,
componentLevelVpdTrackingManufacturingId OCTET STRING,
componentLevelVpdTrackingAction OCTET STRING,
componentLevelVpdTrackingTimestamp OCTET STRING
}
componentLevelVpdTrackingIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD tracking activity log index. View as a table
and not as individual entries for consistent results."
::= { systemComponentLevelVpdTrackingEntry 1 }
componentLevelVpdTrackingFruNumber OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD tracking activity log FRU number. View as a
table and not as individual entries for consistent results."
::= { systemComponentLevelVpdTrackingEntry 2 }
componentLevelVpdTrackingFruName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD tracking activity log FRU name. View as a
table and not as individual entries for consistent results."
::= { systemComponentLevelVpdTrackingEntry 3 }
componentLevelVpdTrackingSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD tracking activity log serial number. View as
a table and not as individual entries for consistent results."
::= { systemComponentLevelVpdTrackingEntry 4 }
componentLevelVpdTrackingManufacturingId OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD tracking activity log manufacturing ID. View
as a table and not as individual entries for consistent results."
::= { systemComponentLevelVpdTrackingEntry 5 }
componentLevelVpdTrackingAction OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD tracking activity log action(added/removed).
View as a table and not as individual entries for consistent results."
::= {systemComponentLevelVpdTrackingEntry 6 }
componentLevelVpdTrackingTimestamp OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System component level VPD tracking activity log timestanp.
View as a table and not as individual entries for consistent results."
::= { systemComponentLevelVpdTrackingEntry 7 }
-- ********************************************************************************
-- Host MAC Address VPD
-- ********************************************************************************
hostMACAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF HostMACAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of MAC addresses of the host NICs.
For consistent results, view as a table and not as individual entries."
::= { vpdInformation 19 }
hostMACAddressEntry OBJECT-TYPE
SYNTAX HostMACAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Host MAC address entry.
For consistent results, view as a table and not as individual entries."
INDEX { hostMACAddressIndex }
::= { hostMACAddressTable 1 }
HostMACAddressEntry ::= SEQUENCE {
hostMACAddressIndex INTEGER,
hostMACAddressDescription DisplayString,
--hostMACAddress OCTET STRING}
hostMACAddress DisplayString}
hostMACAddressIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host MAC address index. View as a table and not as individual
entries for consistent results."
::= { hostMACAddressEntry 1 }
hostMACAddressDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description of the MAC Address entry. View as a table and not as
individual entries for consistent results."
::= { hostMACAddressEntry 2 }
hostMACAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host MAC address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF.
This value must be in the form XX:XX:XX:XX:XX:XX View as a table and not as
individual entries for consistent results."
::= { hostMACAddressEntry 3 }
-- ***********************************************************************
-- System CPU VPD
-- ***********************************************************************
systemCPUVpdTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemCPUVpdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of the system CPU VPD information. View as a
table and not as individual entries for consistent results."
::= { vpdInformation 20 }
systemCPUVpdEntry OBJECT-TYPE
SYNTAX SystemCPUVpdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System CPU VPD entry. View as a table and not as
individual entries for consistent results."
INDEX { cpuVpdIndex }
::= { systemCPUVpdTable 1 }
SystemCPUVpdEntry ::= SEQUENCE {
cpuVpdIndex INTEGER,
cpuVpdDescription DisplayString,
cpuVpdSpeed INTEGER,
cpuVpdIdentifier DisplayString,
cpuVpdType DisplayString,
cpuVpdFamily DisplayString,
cpuVpdCores INTEGER,
cpuVpdThreads INTEGER,
cpuVpdVoltage INTEGER,
cpuVpdDataWidth INTEGER,
cpuVpdHealthStatus DisplayString, --XCC-only
cpuVpdCpuModel DisplayString --XCC-only
}
cpuVpdIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System CPU level VPD index. View as a table and not as individual
entries for consistent results."
::= { systemCPUVpdEntry 1 }
cpuVpdDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System CPU Description. View as a table and not as
individual entries for consistent results."
::= { systemCPUVpdEntry 2 }
cpuVpdSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System cpu speed in MHz. View as a table and not as
individual entries for consistent results."
::= { systemCPUVpdEntry 3 }
cpuVpdIdentifier OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System CPU Identifier. View as a table and not as
individual entries for consistent results."
::= { systemCPUVpdEntry 4 }
cpuVpdType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System cpu Type. View as a table and not as
individual entries for consistent results."
::= { systemCPUVpdEntry 5 }
cpuVpdFamily OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System cpu Family. View as a table and not as
individual entries for consistent results."
::= { systemCPUVpdEntry 6 }
cpuVpdCores OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System cpu number of cores. View as a table and not as
individual entries for consistent results."
::= { systemCPUVpdEntry 7 }
cpuVpdThreads OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System cpu number of threads. View as a table and not as
individual entries for consistent results."
::= { systemCPUVpdEntry 8 }
cpuVpdVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System cpu voltage in millivolts (1125 = 1.125 volts).
View as a table and not as individual entries for consistent
results."
::= { systemCPUVpdEntry 9 }
cpuVpdDataWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System cpu data width in bits. View as a table and not as
individual entries for consistent results."
::= { systemCPUVpdEntry 10 }
cpuVpdHealthStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System cpu health status. View as a table and not as
individual entries for consistent results."
::= { systemCPUVpdEntry 11 }
cpuVpdCpuModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System cpu model. View as a table and not as
individual entries for consistent results."
::= { systemCPUVpdEntry 12 }
-- ***********************************************************************
-- System Memory VPD
-- ***********************************************************************
systemMemoryVpdTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemMemoryVpdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of the system Memory VPD information. View as a
table and not as individual entries for consistent results."
::= { vpdInformation 21 }
systemMemoryVpdEntry OBJECT-TYPE
SYNTAX SystemMemoryVpdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System Memory VPD entry. View as a table and not as
individual entries for consistent results."
INDEX { memoryVpdIndex }
::= { systemMemoryVpdTable 1 }
SystemMemoryVpdEntry ::= SEQUENCE {
memoryVpdIndex INTEGER,
memoryVpdDescription DisplayString,
memoryVpdPartNumber DisplayString,
memoryVpdFRUSerialNumber DisplayString,
memoryVpdManufactureDate DisplayString,
memoryVpdType DisplayString,
memoryVpdSize INTEGER,
memoryHealthStatus DisplayString,
memoryConfigSpeed INTEGER,
memoryRatedSpeed INTEGER,
memoryLenovoPartNumber DisplayString,
memoryVpdAEPFlag INTEGER
}
memoryVpdIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Memory level VPD index. View as a table and not as individual
entries for consistent results."
::= { systemMemoryVpdEntry 1 }
memoryVpdDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System memory Description (e.g. DIMM 1). View as a table and not as
individual entries for consistent results."
::= { systemMemoryVpdEntry 2 }
memoryVpdPartNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Memory Part Number. View as a table and not as
individual entries for consistent results."
::= { systemMemoryVpdEntry 3 }
memoryVpdFRUSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System memory Serial Number. View as a table and not as
individual entries for consistent results."
::= { systemMemoryVpdEntry 4 }
memoryVpdManufactureDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System memory Manufacture Date in week/year format (e.g. 3609).
View as a table and not as individual entries for consistent
results."
::= { systemMemoryVpdEntry 5 }
memoryVpdType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System memory Type (e.g. DDR III SDRAM). View as a table and not as
individual entries for consistent results."
::= { systemMemoryVpdEntry 6 }
memoryVpdSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System memory size in GigaBytes. View as a table and not as
individual entries for consistent results."
::= { systemMemoryVpdEntry 7 }
memoryHealthStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A description of the memory component status."
::= { systemMemoryVpdEntry 8 }
memoryConfigSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System configured memory clock speed in MHz. View as a table and not as
individual entries for consistent results."
::= { systemMemoryVpdEntry 9 }
memoryRatedSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System rated memory clock speed in MB/s. View as a table and not as
individual entries for consistent results."
::= { systemMemoryVpdEntry 10 }
memoryLenovoPartNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Memory Lenovo related Part Number. View as a table and not as
individual entries for consistent results."
::= { systemMemoryVpdEntry 11 }
memoryVpdAEPFlag OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Judge System DIMM belong to AEP DIMM. View as a table and not as
individual entries for consistent results."
::= { systemMemoryVpdEntry 12 }
-- ***********************************************************************
-- System AEP DIMM VPD
-- ***********************************************************************
systemAepDIMMVpdTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemAepDIMMVpdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of the system AEP DIMM VPD information. View as a
table and not as individual entries for consistent results."
::= { vpdInformation 22 }
systemAepDIMMVpdEntry OBJECT-TYPE
SYNTAX SystemAepDIMMVpdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System AEP DIMM VPD entry. View as a table and not as
individual entries for consistent results."
INDEX { aepDIMMVpdIndex }
::= { systemAepDIMMVpdTable 1 }
SystemAepDIMMVpdEntry ::= SEQUENCE {
aepDIMMVpdIndex INTEGER,
aepDIMMVpdMemory DisplayString,
aepDIMMVpdBankLocator DisplayString,
aepDIMMVpdMaxSpeed DisplayString,
aepDIMMVpdClockSpeed DisplayString,
aepDIMMVpdManufacturer DisplayString,
aepDIMMVpdSerialNumber DisplayString,
aepDIMMVpdPartNumber DisplayString,
aepDIMMVpdRawCapacity DisplayString,
aepDIMMVpdMemoryCapacity DisplayString,
aepDIMMVpdAppDirectCapacity DisplayString,
aepDIMMVpdUnconfiguredCapacity DisplayString,
aepDIMMVpdInaccessibleCapacity DisplayString,
aepDIMMVpdReservedCapacity DisplayString,
aepDIMMVpdClassification DisplayString,
aepDIMMVpdFirmwareVersion DisplayString,
aepDIMMVpdSoftwareID DisplayString
}
aepDIMMVpdIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM VPD index. View as a table and not as individual
entries for consistent results."
::= { systemAepDIMMVpdEntry 1 }
aepDIMMVpdMemory OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Description (e.g. DIMM 1). View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 2 }
aepDIMMVpdBankLocator OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Locator which manage AEP DIMM (e.g CPU 1) . View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 3 }
aepDIMMVpdMaxSpeed OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM MAX Speed. View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 4 }
aepDIMMVpdClockSpeed OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Clock Speed. View as a table and not as individual entries for consistent
results."
::= { systemAepDIMMVpdEntry 5 }
aepDIMMVpdManufacturer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Manufacturer. View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 6 }
aepDIMMVpdSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Serial Number. View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 7 }
aepDIMMVpdPartNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Part Number. View as a table and not as individual
entries for consistent results."
::= { systemAepDIMMVpdEntry 8 }
aepDIMMVpdRawCapacity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Raw Capacity. View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 9 }
aepDIMMVpdMemoryCapacity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Memory Capacity. View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 10 }
aepDIMMVpdAppDirectCapacity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM APP Direct Capacity. View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 11 }
aepDIMMVpdUnconfiguredCapacity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Unconfigureed Capacity. View as a table and not as individual
entries for consistent results."
::= { systemAepDIMMVpdEntry 12 }
aepDIMMVpdInaccessibleCapacity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Inaccessible Capacity. View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 13 }
aepDIMMVpdReservedCapacity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Reserved Capacity. View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 14 }
aepDIMMVpdClassification OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Classification. View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 15 }
aepDIMMVpdFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Firmware Version. View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 16 }
aepDIMMVpdSoftwareID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System AEP DIMM Software ID. View as a table and not as
individual entries for consistent results."
::= { systemAepDIMMVpdEntry 17 }
-- ********************************************************************************
-- Users
-- ********************************************************************************
--
users OBJECT IDENTIFIER ::= { monitors 6 }
-- ********************************************************************************
-- XCC Users
-- ********************************************************************************
--
xccUsers OBJECT IDENTIFIER ::= { users 1 }
currentlyLoggedInTable OBJECT-TYPE
SYNTAX SEQUENCE OF CurrentlyLoggedInEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of XCC users currently logged in."
::= { xccUsers 1 }
currentlyLoggedInEntry OBJECT-TYPE
SYNTAX CurrentlyLoggedInEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"XCC users currently logged in entries."
INDEX { currentlyLoggedInEntryIndex }
::= { currentlyLoggedInTable 1 }
CurrentlyLoggedInEntry ::= SEQUENCE {
currentlyLoggedInEntryIndex INTEGER,
currentlyLoggedInEntryUserId OCTET STRING,
currentlyLoggedInEntryAccMethod OCTET STRING
}
currentlyLoggedInEntryIndex OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for XCC users currently logged in."
::= { currentlyLoggedInEntry 1 }
currentlyLoggedInEntryUserId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name for XCC users currently logged in."
::= { currentlyLoggedInEntry 2 }
currentlyLoggedInEntryAccMethod OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Access method for XCC users currently logged in."
::= { currentlyLoggedInEntry 3 }
-- ********************************************************************************
-- LEDs
-- ********************************************************************************
leds OBJECT IDENTIFIER ::= { monitors 8 }
identityLED OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1),
blinking(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether the front panel identity LED is on,off,
or blinking and allows user to change it."
::= { leds 1 }
allLEDsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AllLEDsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of LEDs detailed information."
::= { leds 2 }
allLEDsEntry OBJECT-TYPE
SYNTAX AllLEDsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"LEDs Details entry"
INDEX { ledIndex }
::= { allLEDsTable 1 }
AllLEDsEntry ::= SEQUENCE {
ledIndex INTEGER,
ledIdentifier INTEGER,
ledLabel DisplayString,
ledState INTEGER,
ledColor DisplayString
}
ledIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The LED index number.
For consistent results, view as a table and not as individual entries."
::= { allLEDsEntry 1 }
ledIdentifier OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique identifier for this LED
For consistent results, view as a table and not as individual entries."
::= { allLEDsEntry 2 }
ledLabel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Text label for a LED.
For consistent results, view as a table and not as individual entries."
::= { allLEDsEntry 4 }
ledState OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1),
blinking(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Text description which denotes color or on/off/blink state for a LED.
For consistent results, view as a table and not as individual entries."
::= { allLEDsEntry 5 }
ledColor OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Color of this LED.
For consistent results, view as a table and not as individual entries."
::= { allLEDsEntry 6 }
informationLED OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1),
blinking(2),
notAvailable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether the front panel Information LED is on,off,
or blinking and allows user to change it. The only value the user is
allowed to enter is 0 for off. User may not turn this LED on or cause
it to blink."
::= { leds 3 }
-- ********************************************************************************
-- Power Management
-- ********************************************************************************
fuelGauge OBJECT IDENTIFIER ::= { monitors 10 }
-- ********************************************************************************
-- Fuel Gauge
-- ********************************************************************************
fuelGaugeInformation OBJECT IDENTIFIER ::= { fuelGauge 1 }
fuelGaugePowerCappingPolicySetting OBJECT-TYPE
SYNTAX INTEGER {
noPowerLimit(0),
staticPowerLimit(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Capping Policy. Rack system only.
No Power Limit - The maximum power limit will be determined by the active Power Redundancy policy.
Static Power Limit - Sets the overall system power limit. In a situation where powering on a component
would cause the limit to be exceeded, the component would not be permitted to power on."
::= { fuelGaugeInformation 1 }
fuelGaugeStaticPowerPcapSoftMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field displays power capping soft minimum value. Rack system only."
::= { fuelGaugeInformation 2 }
fuelGaugeStaticPowerPcapMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field displays power capping minimum value. Rack system only."
::= { fuelGaugeInformation 3 }
fuelGaugeStaticPowerPcapCurrentSetting OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field is used to display or set the current power capping value. Rack system only."
::= { fuelGaugeInformation 4 }
fuelGaugeStaticPowerPcapMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field displays power capping maximum value. Rack system only."
::= { fuelGaugeInformation 5 }
fuelGaugeStaticPowerPcapMode OBJECT-TYPE
SYNTAX INTEGER {
output(0),
input(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field is used to display or set the all Power Cap settings to output or input. Rack system only."
::= { fuelGaugeInformation 6 }
fuelGaugeSystemMaxPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field displays the system maximum power available value. Rack system only."
::= { fuelGaugeInformation 7 }
fuelGaugePowerRemaining OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field displays power remaining value. Rack system only."
::= { fuelGaugeInformation 8 }
fuelGaugeTotalPowerAvailable OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field displays the calculated total remaining power available value. Rack system only."
::= { fuelGaugeInformation 9 }
fuelGaugeTotalPowerInUse OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field displays total power in use value."
::= { fuelGaugeInformation 10 }
fuelGaugePowerConsumptionCpu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field displays the power consumption of the processors."
::= { fuelGaugeInformation 11 }
fuelGaugePowerConsumptionMemory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field displays the power consumption of the memory."
::= { fuelGaugeInformation 12 }
fuelGaugePowerConsumptionOther OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field displays the power consumption of other entities than processors and memory."
::= { fuelGaugeInformation 13 }
-- ********************************************************************************
-- Power Policy Information
-- ********************************************************************************
powerPolicyInformation OBJECT IDENTIFIER ::= { fuelGauge 2 }
powerPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerPolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Power Policy information for all power domains. Reading this table information about the available power policies that can be configured and which is currently selected. Rack system only"
::= { powerPolicyInformation 1 }
powerPolicyEntry OBJECT-TYPE
SYNTAX PowerPolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Power Policy Entry"
INDEX { powerPolicyIndex }
::= { powerPolicyTable 1 }
PowerPolicyEntry ::= SEQUENCE {
powerPolicyIndex INTEGER,
powerPolicyName OCTET STRING,
powerPolicyPwrSupplyFailureLimit INTEGER,
powerPolicyMaxPowerLimit INTEGER,
powerPolicyEstimatedUtilization INTEGER,
powerPolicyActivate INTEGER
}
powerPolicyIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique idenitifier of a row in the powerPolicyTable."
::= { powerPolicyEntry 1 }
powerPolicyName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The short name of the power policy. The following are the possible names and their detailed description:
Power Module Redundant
In redundant mode, the server is guaranteed to continue to remain operational with the loss of one power supply
Power Module Non-Redundant
In non-redundant mode, the server is not guaranteed to remain operational with the loss of a power supply. The system will throttle if a power supply fails in an attempt to stay up and running."
::= { powerPolicyEntry 2 }
powerPolicyPwrSupplyFailureLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of power supplies that can fail in a chassis while still providing redundancy."
::= { powerPolicyEntry 3 }
powerPolicyMaxPowerLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum power available (in watts), based on the number of power modules and the Power Management Policy setting."
::= { powerPolicyEntry 4 }
powerPolicyEstimatedUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The estimated utilization (as a percentage) based on current power usage."
::= { powerPolicyEntry 5 }
powerPolicyActivate OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object provides the status of this power policy. If the
value is enabled(1), it means this is the active power policy for the
associated domain. When set to a value of enabled(1), the power policy will be made the active one for the associated domain. A set of disabled(0) is not allowed."
::= { powerPolicyEntry 6 }
powerRestorePolicyControl OBJECT IDENTIFIER ::= { powerPolicyInformation 2 }
powerRestorePolicy OBJECT-TYPE
SYNTAX INTEGER {
alwaysoff(0),
restore(1),
alwayson(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Restore Policy determines the mode of operation if a power loss occurs. This setting can also be configured via BIOS F1 setup. Rack system only.
alwaysoff: System will remain off once power is restored.
restore: Restores system to the same state it was before power failed.
alwayson: System will automatically power on once power is restored."
::= { powerRestorePolicyControl 1 }
powerRestoreDelay OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
random(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Restore Delay is executed when power restore policy is set to alwayson or restore(if the previous state was power-on). Rack system only.
disabled: Power on the server without after AC is restored.
random: Provide a random delay between 1 and 15 seconds from the time when AC is restored to the time when the server is automatically powered on."
::= { powerRestorePolicyControl 2 }
-- ********************************************************************************
-- Power Domain Power Trending
-- ********************************************************************************
powerPowerTrending OBJECT IDENTIFIER ::= { fuelGauge 3 }
-- ********************************************************************************
-- Power Domain Power Trending Table
-- ********************************************************************************
powerTrendingSampleTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerTrendingSampleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Power Domain 1 Power Trending Information."
::= { powerPowerTrending 1 }
powerTrendingSampleEntry OBJECT-TYPE
SYNTAX PowerTrendingSampleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Power Domain 1 Power Trending Sample entry."
INDEX { powerTrendingSampleIndex }
::= { powerTrendingSampleTable 1 }
PowerTrendingSampleEntry ::= SEQUENCE {
powerTrendingSampleIndex INTEGER,
powerTrendingSampleTimeStamp OCTET STRING,
powerTrendingSampleInputAve INTEGER,
powerTrendingSampleInputMin INTEGER,
powerTrendingSampleInputMax INTEGER,
powerTrendingSampleOutputAve INTEGER,
powerTrendingSampleOutputMin INTEGER,
powerTrendingSampleOutputMax INTEGER
}
powerTrendingSampleIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Trending Sample Table Index."
::= { powerTrendingSampleEntry 1 }
powerTrendingSampleTimeStamp OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Trending Sample Table Timestamp."
::= { powerTrendingSampleEntry 2 }
powerTrendingSampleInputAve OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Trending Table Input Average Power in the last 24 hours."
::= { powerTrendingSampleEntry 3 }
powerTrendingSampleInputMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Trending Table Input Minimum Power in the last 24 hours."
::= { powerTrendingSampleEntry 4 }
powerTrendingSampleInputMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Trending Table Input Maximum Power in the last 24 hours."
::= { powerTrendingSampleEntry 5 }
powerTrendingSampleOutputAve OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Trending Table Output Average Power in the last 24 hours."
::= { powerTrendingSampleEntry 6 }
powerTrendingSampleOutputMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Trending Table Output Minimum Power in the last 24 hours."
::= { powerTrendingSampleEntry 7 }
powerTrendingSampleOutputMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Trending Table Output Maximum Power in the last 24 hours."
::= { powerTrendingSampleEntry 8 }
-- ***********************************************************************
-- Power Module
-- ***********************************************************************
powerModule OBJECT IDENTIFIER ::= { monitors 11 }
powerNumber OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "The present number of rows in the power module table. Rack system only."
::= { powerModule 1 }
powerTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This table contains power inventory information. Rack system only."
::= { powerModule 2 }
powerEntry OBJECT-TYPE
SYNTAX PowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Each row contains parameters related to a power module inventory channel."
INDEX { powerIndex }
::= { powerTable 1 }
PowerEntry ::=
SEQUENCE {
powerIndex INTEGER (0..100),
powerFruName DisplayString,
powerPartNumber DisplayString,
powerFRUNumber DisplayString,
powerFRUSerialNumber DisplayString,
powerHealthStatus DisplayString
}
powerIndex OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular power module inventory channel."
::= { powerEntry 1 }
powerFruName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "power module FRU name."
::= { powerEntry 2 }
powerPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "power module Part Number. View as a table and not as individual entries for consistent results."
::= { powerEntry 3 }
powerFRUNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "power module FRU Number. View as a table and not as individual entries for consistent results."
::= { powerEntry 4 }
powerFRUSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "power module Serial Number. View as a table and not as individual entries for consistent results."
::= { powerEntry 5 }
powerHealthStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A description of the power module status."
::= { powerEntry 6 }
-- ***********************************************************************
-- Disk
-- ***********************************************************************
disks OBJECT IDENTIFIER ::= { monitors 12 }
diskNumber OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "The present number of rows in the disk module table."
::= { disks 1 }
diskTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This table contains disk inventory information."
::= { disks 2 }
diskEntry OBJECT-TYPE
SYNTAX DiskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Each row contains parameters related to a disk module inventory channel."
INDEX { diskIndex }
::= { diskTable 1 }
DiskEntry ::=
SEQUENCE {
diskIndex INTEGER (0..100),
diskFruName DisplayString,
diskHealthStatus DisplayString
}
diskIndex OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular
disk module inventory channel."
::= { diskEntry 1 }
diskFruName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "disk module FRU name."
::= { diskEntry 2 }
diskHealthStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A description of the disk module status."
::= { diskEntry 3 }
-- ********************************************************************************
-- Local Storage
-- ********************************************************************************
localStorage OBJECT IDENTIFIER ::= { monitors 13 }
-- ********************************************************************************
-- RAID Group. Only the platform supports the OOB RAID function and
-- RAID cards, this table can be queried.
-- ********************************************************************************
raid OBJECT IDENTIFIER ::= { localStorage 1 }
-- ********************************************************************************
-- Physical Resource: The properties of RAID Controller
-- ********************************************************************************
raidOOBCapable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "If raidOOBCapable is disabled, all the RAID information is not available."
::= { raid 1 }
raidControllerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaidControllerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Local Storage RAID Controller information."
::= { raid 2 }
raidControllerEntry OBJECT-TYPE
SYNTAX RaidControllerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RAID Controller Entry."
INDEX { raidCtrlIndex }
::= { raidControllerTable 1 }
RaidControllerEntry ::= SEQUENCE {
raidCtrlIndex INTEGER,
raidCtrlName DisplayString,
raidCtrlVPDProdName DisplayString,
raidCtrlFWPkgVersion DisplayString,
raidCtrlBatBCK INTEGER,
raidCtrlVPDManufacture DisplayString,
raidCtrlVPDUUID DisplayString,
raidCtrlVPDMachineType DisplayString,
raidCtrlVPDModel DisplayString,
raidCtrlVPDSerialNo DisplayString,
raidCtrlVPDFRUNo DisplayString,
raidCtrlVPDPartNo DisplayString,
raidCtrlCacheMdlStatus DisplayString,
raidCtrlCacheMdlMemSize DisplayString,
raidCtrlCacheMdlSerialNo DisplayString,
raidCtrlPCISlotNo INTEGER,
raidCtrlPCIBusNo INTEGER,
raidCtrlPCIDevNo INTEGER,
raidCtrlPCIFuncNo INTEGER,
raidCtrlPCIDevID DisplayString,
raidCtrlPCISubDevID DisplayString,
raidCtrlBatBCKProdName DisplayString,
raidCtrlBatBCKManufacture DisplayString,
raidCtrlBatBCKStatus DisplayString,
raidCtrlBatBCKType DisplayString,
raidCtrlBatBCKChem DisplayString,
raidCtrlBatBCKSerialNo DisplayString,
raidCtrlBatBCKChgCap DisplayString,
raidCtrlBatBCKDgnChgCap DisplayString,
raidCtrlBatBCKCrtTemp DisplayString,
raidCtrlBatBCKFirmware DisplayString,
raidCtrlBatBCKDgnVoltage DisplayString,
raidCtrlBatBCKVoltage DisplayString,
raidCtrlBatCurrent DisplayString,
raidCtrlFWNames DisplayString,
raidCtrlPortDetails DisplayString,
raidCtrlStoragepools DisplayString,
raidCtrlDrives DisplayString
}
raidCtrlIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular RAID controller."
::= { raidControllerEntry 1 }
raidCtrlName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to offer a name of one RAID controller."
::= { raidControllerEntry 2 }
raidCtrlVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name of a particular RAID controller."
::= { raidControllerEntry 3 }
raidCtrlFWPkgVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Firmware Package Version of a particular RAID controller."
::= { raidControllerEntry 4 }
raidCtrlBatBCK OBJECT-TYPE
SYNTAX INTEGER {
uninstalled(0),
installed(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Whether Battery Backup of a particular RAID controller is installed."
::= { raidControllerEntry 5 }
raidCtrlVPDManufacture OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Manufacture of a particular RAID controller."
::= { raidControllerEntry 6 }
raidCtrlVPDUUID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Device ID (UUID) of a particular RAID controller."
::= { raidControllerEntry 7 }
raidCtrlVPDMachineType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Model Type/Model of a particular RAID controller."
::= { raidControllerEntry 8 }
raidCtrlVPDModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Model Type/Model of a particular RAID controller."
::= { raidControllerEntry 9 }
raidCtrlVPDSerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Serial Number of a particular RAID controller."
::= { raidControllerEntry 10 }
raidCtrlVPDFRUNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The FRU Number of a particular RAID controller."
::= { raidControllerEntry 11 }
raidCtrlVPDPartNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Part Number of a particular RAID controller."
::= { raidControllerEntry 12 }
raidCtrlCacheMdlStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Cache Model Status of a particular RAID controller."
::= { raidControllerEntry 13 }
raidCtrlCacheMdlMemSize OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Cache Model Memory Size of a particular RAID controller."
::= { raidControllerEntry 14 }
raidCtrlCacheMdlSerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Cache Model Serial Number of a particular RAID controller."
::= { raidControllerEntry 15 }
raidCtrlPCISlotNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Slot Number of a particular RAID controller."
::= { raidControllerEntry 16 }
raidCtrlPCIBusNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Bus Number of a particular RAID controller."
::= { raidControllerEntry 17 }
raidCtrlPCIDevNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Device Number of a particular RAID controller."
::= { raidControllerEntry 18 }
raidCtrlPCIFuncNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Function Number of a particular RAID controller."
::= { raidControllerEntry 19 }
raidCtrlPCIDevID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Device ID of a particular RAID controller."
::= { raidControllerEntry 20 }
raidCtrlPCISubDevID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Subsystem Device ID of a particular RAID controller."
::= { raidControllerEntry 21 }
raidCtrlBatBCKProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 22 }
raidCtrlBatBCKManufacture OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Manufacture of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 23 }
raidCtrlBatBCKStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Status of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 24 }
raidCtrlBatBCKType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Battery Type of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 25 }
raidCtrlBatBCKChem OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Chemistry of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 26 }
raidCtrlBatBCKSerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Serial Number of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 27 }
raidCtrlBatBCKChgCap OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Charge Capacity of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 28 }
raidCtrlBatBCKFirmware OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Firmware Info of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 29 }
raidCtrlBatBCKDgnVoltage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Designed Voltage of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 30 }
raidCtrlBatBCKVoltage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Voltage of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 31 }
raidCtrlBatCurrent OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Current of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 32 }
raidCtrlBatBCKDgnChgCap OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Design Charge Capacity of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 33 }
raidCtrlBatBCKCrtTemp OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Current degree Celsius temperature of Battery Backup of a particular RAID controller."
::= { raidControllerEntry 34 }
raidCtrlFWNames OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "All the Firmware Names of a particular RAID controller."
::= { raidControllerEntry 35 }
raidCtrlPortDetails OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "All the Port Details of a particular RAID controller, including Port Address and Port Controller Type."
::= { raidControllerEntry 36 }
raidCtrlStoragepools OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The storage pools list of a particular RAID controller."
::= { raidControllerEntry 37 }
raidCtrlDrives OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Physical drives list of a particular RAID controller."
::= { raidControllerEntry 38 }
-- ********************************************************************************
-- Physical Resource: The properties of RAID Driver
-- ********************************************************************************
raidDriveTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaidDriveEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Logic Storage RAID Drive information."
::= { raid 3 }
raidDriveEntry OBJECT-TYPE
SYNTAX RaidDriveEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RAID Drive Entry."
INDEX { raidDriveIndex }
::= { raidDriveTable 1 }
RaidDriveEntry ::= SEQUENCE {
raidDriveIndex INTEGER,
raidDriveName DisplayString,
raidDriveVPDProdName DisplayString,
raidDriveState DisplayString,
raidDriveSlotNo INTEGER,
raidDriveDeviceID DisplayString,
raidDriveDiskType DisplayString,
raidDriveMediaType DisplayString,
raidDriveSpeed DisplayString,
raidDriveCurTemp DisplayString,
raidDriveHealthStataus DisplayString,
raidDriveCapacity DisplayString,
raidDriveVPDManufacture DisplayString,
raidDriveEnclosureID DisplayString,
raidDriveVPDMachineType DisplayString,
raidDriveVPDModel DisplayString,
raidDriveVPDSerialNo DisplayString,
raidDriveVPDFRUNo DisplayString,
raidDriveVPDPartNo DisplayString,
raidDriveFWNames DisplayString,
raidDriveRotationRate DisplayString,
raidDriveMediaErrCnt Gauge,
raidDriveOtherErrCnt Gauge,
raidDrivePredFailCnt Gauge,
raidDriveRemainingLife DisplayString,
raidDriveFdeCapable INTEGER,
raidDriveSecured INTEGER
}
raidDriveIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular RAID drive."
::= { raidDriveEntry 1 }
raidDriveName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A particular drive name."
::= { raidDriveEntry 2 }
raidDriveVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name of a particular RAID drive."
::= { raidDriveEntry 3 }
raidDriveState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The State of a particular RAID drive."
::= { raidDriveEntry 4 }
raidDriveSlotNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Slot No. of a particular RAID drive."
::= { raidDriveEntry 5 }
raidDriveDeviceID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Device ID of a particular RAID drive."
::= { raidDriveEntry 6 }
raidDriveDiskType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Disk Type of a particular RAID drive."
::= { raidDriveEntry 7 }
raidDriveMediaType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Media Type of a particular RAID drive."
::= { raidDriveEntry 8 }
raidDriveSpeed OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Speed of a particular RAID drive."
::= { raidDriveEntry 9 }
raidDriveCurTemp OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Current degree Celsius temperature of a particular RAID drive."
::= { raidDriveEntry 10 }
raidDriveHealthStataus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Health Status of a particular RAID drive."
::= { raidDriveEntry 11 }
raidDriveCapacity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Capacity of a particular RAID drive."
::= { raidDriveEntry 12 }
raidDriveVPDManufacture OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Manufacture of a particular RAID drive."
::= { raidDriveEntry 13 }
raidDriveEnclosureID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Enclosure ID of a particular RAID drive."
::= { raidDriveEntry 14 }
raidDriveVPDMachineType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Machine type of a particular RAID drive."
::= { raidDriveEntry 15 }
raidDriveVPDModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Model of a particular RAID drive."
::= { raidDriveEntry 16 }
raidDriveVPDSerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Serial No. of a particular RAID drive."
::= { raidDriveEntry 17 }
raidDriveVPDFRUNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The FRU No. of a particular RAID drive."
::= { raidDriveEntry 18 }
raidDriveVPDPartNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Part No. of a particular RAID drive."
::= { raidDriveEntry 19 }
raidDriveFWNames OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "All the Firmware Names of a particular RAID drive."
::= { raidDriveEntry 20 }
raidDriveRotationRate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Rotation Rate of a particular RAID drive."
::= { raidDriveEntry 21 }
raidDriveMediaErrCnt OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Media Error Count of a particular RAID drive."
::= { raidDriveEntry 22 }
raidDriveOtherErrCnt OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Other Error Count of a particular RAID drive."
::= { raidDriveEntry 23 }
raidDrivePredFailCnt OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Predication Fail Count of a particular RAID drive."
::= { raidDriveEntry 24 }
raidDriveRemainingLife OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Remaining life of a particular RAID drive. It is available only for SSD Drive."
::= { raidDriveEntry 25 }
raidDriveFdeCapable OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates Full Disk Encryption Capable of a particular RAID drive."
::= { raidDriveEntry 26 }
raidDriveSecured OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates Secured status of a particular RAID drive."
::= { raidDriveEntry 27 }
-- *************************************************************************************
-- Physical Resource: The properties of RAID Controller Firmwares information
-- *************************************************************************************
raidControllerFirmwareTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaidControllerFirmwareEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Logic Storage RAID Controller Firmware information."
::= { raid 4 }
raidControllerFirmwareEntry OBJECT-TYPE
SYNTAX RaidControllerFirmwareEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RAID Firmware Entry."
INDEX { raidControllerFirmwareIndex }
::= { raidControllerFirmwareTable 1 }
RaidControllerFirmwareEntry ::= SEQUENCE {
raidControllerFirmwareIndex INTEGER,
raidControllerFirmwareName DisplayString,
raidControllerFirmwareCtrlName DisplayString,
raidControllerFirmwareDescription DisplayString,
raidControllerFirmwareManufacture DisplayString,
raidControllerFirmwareVersion DisplayString,
raidControllerFirmwareReleaseDate DisplayString
}
raidControllerFirmwareIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular RAID Controller firmware."
::= { raidControllerFirmwareEntry 1 }
raidControllerFirmwareName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Name of a particular RAID Controller firmware."
::= { raidControllerFirmwareEntry 2 }
raidControllerFirmwareCtrlName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The controller name of the firmwares."
::= { raidControllerFirmwareEntry 3 }
raidControllerFirmwareDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Description of a particular RAID Controller firmware."
::= { raidControllerFirmwareEntry 4 }
raidControllerFirmwareManufacture OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Manufacture of a particular RAID Controller firmware."
::= { raidControllerFirmwareEntry 5 }
raidControllerFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Version of a particular RAID Controller firmware."
::= { raidControllerFirmwareEntry 6 }
raidControllerFirmwareReleaseDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Release Date of a particular RAID Controller firmware."
::= { raidControllerFirmwareEntry 7 }
-- *************************************************************************************
-- Physical Resource: The properties of RAID Drive Firmwares information
-- ********************************************************************************
raidDriveFirmwareTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaidDriveFirmwareEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Logic Storage RAID Drive Firmware information."
::= { raid 5 }
raidDriveFirmwareEntry OBJECT-TYPE
SYNTAX RaidDriveFirmwareEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RAID Drive Firmware Entry."
INDEX { raidDriveFirmwareIndex }
::= { raidDriveFirmwareTable 1 }
RaidDriveFirmwareEntry ::= SEQUENCE {
raidDriveFirmwareIndex INTEGER,
raidDriveFirmwareName DisplayString,
raidDriveFirmwareDriveName DisplayString,
raidDriveFirmwareDescription DisplayString,
raidDriveFirmwareManufacture DisplayString,
raidDriveFirmwareVersion DisplayString,
raidDriveFirmwareReleaseDate DisplayString
}
raidDriveFirmwareIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular RAID Drive firmware."
::= { raidDriveFirmwareEntry 1 }
raidDriveFirmwareName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Name of a particular RAID Drive firmware."
::= { raidDriveFirmwareEntry 2 }
raidDriveFirmwareDriveName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The drive name of the firmwares."
::= { raidDriveFirmwareEntry 3 }
raidDriveFirmwareDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Description of a particular RAID Drive firmware."
::= { raidDriveFirmwareEntry 4 }
raidDriveFirmwareManufacture OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Manufacture of a particular RAID Drive firmware."
::= { raidDriveFirmwareEntry 5 }
raidDriveFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Version of a particular RAID Drive firmware."
::= { raidDriveFirmwareEntry 6 }
raidDriveFirmwareReleaseDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Release Date of a particular RAID Drive firmware."
::= { raidDriveFirmwareEntry 7 }
-- ********************************************************************************
-- Physical Resource: The properties of RAID Storagepool information
-- ********************************************************************************
raidStoragepoolTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaidStoragepoolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Logic Storage RAID Storagepool information."
::= { raid 6 }
raidStoragepoolEntry OBJECT-TYPE
SYNTAX RaidStoragepoolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RAID Storagepool Entry."
INDEX { raidStoragepoolIndex }
::= { raidStoragepoolTable 1 }
RaidStoragepoolEntry ::= SEQUENCE {
raidStoragepoolIndex INTEGER,
raidStoragepoolName DisplayString,
raidStoragepoolControllerName DisplayString,
raidStoragepoolState DisplayString,
raidStoragepoolCapacity DisplayString,
raidStoragepoolVols DisplayString,
raidStoragepoolDrives DisplayString
}
raidStoragepoolIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular RAID storagepool."
::= { raidStoragepoolEntry 1 }
raidStoragepoolName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of a particular RAID storagepool."
::= { raidStoragepoolEntry 2 }
raidStoragepoolControllerName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The controller name of the storagepool."
::= { raidStoragepoolEntry 3 }
raidStoragepoolState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The RAID State of a particular RAID storagepool."
::= { raidStoragepoolEntry 4 }
raidStoragepoolCapacity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Capacity of a particular RAID storagepool, including total capacity and free capacity."
::= { raidStoragepoolEntry 5 }
raidStoragepoolVols OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The volumes list of a particular RAID storagepool."
::= { raidStoragepoolEntry 6 }
raidStoragepoolDrives OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The physical drives list of a particular RAID storagepool."
::= { raidStoragepoolEntry 7 }
-- ********************************************************************************
-- Physical Resource: The properties of RAID Volume information
-- ********************************************************************************
raidVolumeTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaidVolumeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Logic Storage RAID Volume information."
::= { raid 7 }
raidVolumeEntry OBJECT-TYPE
SYNTAX RaidVolumeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RAID Volume Entry."
INDEX { raidVolumeIndex }
::= { raidVolumeTable 1 }
RaidVolumeEntry ::= SEQUENCE {
raidVolumeIndex INTEGER,
raidVolumeName DisplayString,
raidVolumeControllerName DisplayString,
raidVolumeStatus DisplayString,
raidVolumeCapacity DisplayString,
raidVolumeStripSize DisplayString,
raidVolumeBootable DisplayString
}
raidVolumeIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular RAID volume."
::= { raidVolumeEntry 1 }
raidVolumeName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Name of a particular RAID volume."
::= { raidVolumeEntry 2 }
raidVolumeControllerName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The controller name of the volume."
::= { raidVolumeEntry 3 }
raidVolumeStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Status of a particular RAID volume."
::= { raidVolumeEntry 4 }
raidVolumeCapacity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Capacity of a particular RAID volume."
::= { raidVolumeEntry 5 }
raidVolumeStripSize OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The strip size of the RAID volume."
::= { raidVolumeEntry 6 }
raidVolumeBootable OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Whether the RAID volume is bootable."
::= { raidVolumeEntry 7 }
-- ********************************************************************************
-- Adapter
-- ********************************************************************************
adapters OBJECT IDENTIFIER ::= { monitors 14 }
-- *************************************************************************************
-- Physical Resource: The properties of Adapters generic information
-- ********************************************************************************
adapterOOBCapable OBJECT-TYPE
SYNTAX INTEGER{
disable(0),
enable(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "If adapterOOBCapable is disabled, all the adapter information is not available."
::= { adapters 1 }
adapterGenericTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdapterGenericEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of all adapters generic information"
::= { adapters 2 }
adapterGenericEntry OBJECT-TYPE
SYNTAX AdapterGenericEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Adapters generic information entry."
INDEX { adapterGenericIndex }
::= { adapterGenericTable 1 }
AdapterGenericEntry ::= SEQUENCE {
adapterGenericIndex INTEGER,
adapterGenericVPDProdName DisplayString,
adapterGenericSlotNo INTEGER,
adapterGenericLocation DisplayString,
adapterGenericCardInterface DisplayString
}
adapterGenericIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular PCI adapter."
::= { adapterGenericEntry 1 }
adapterGenericVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name of a particular PCI adapter. And if the Product Name contains PFA, PFA is in HEX."
::= { adapterGenericEntry 2 }
adapterGenericSlotNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This Slot No. of a particular PCI adapter"
::= { adapterGenericEntry 3 }
adapterGenericLocation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Location of a particular PCI adapter."
::= { adapterGenericEntry 4 }
adapterGenericCardInterface OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Card Interface of a particular PCI adapter."
::= { adapterGenericEntry 5 }
-- *************************************************************************************
-- Firmware Information: The properties of Network Function information
-- ********************************************************************************
adapterNetworkFunctionTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdapterNetworkFunctionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Network Function information."
::= { adapters 3 }
adapterNetworkFunctionEntry OBJECT-TYPE
SYNTAX AdapterNetworkFunctionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Network function information entry."
INDEX { adapterNetworkFunctionIndex }
::= { adapterNetworkFunctionTable 1 }
AdapterNetworkFunctionEntry ::= SEQUENCE {
adapterNetworkFunctionIndex INTEGER,
adapterNetworkFunctionNetworkVPDProdName DisplayString,
adapterNetworkFunctionAdapterVPDProdName DisplayString,
adapterNetworkFunctionNetworkVPDManufacturer DisplayString,
adapterNetworkFunctionNetworkVPDUUID DisplayString,
adapterNetworkFunctionNetworkVPDModel DisplayString,
adapterNetworkFunctionNetworkVPDSerialNo DisplayString,
adapterNetworkFunctionNetworkVPDFRUNo DisplayString,
adapterNetworkFunctionNetworkVPDPartNo DisplayString,
adapterNetworkFunctionFoDUID DisplayString,
adapterNetworkFunctionSupportHotPlug INTEGER,
adapterNetworkFunctionPhysicalPortNumber INTEGER,
adapterNetworkFunctionMaxPortNumber INTEGER,
adapterNetworkFunctionPortNumber INTEGER,
adapterNetworkFunctionMaxDataWidth INTEGER,
adapterNetworkFunctionPackageType DisplayString,
adapterNetworkFunctionPCIBusNo INTEGER,
adapterNetworkFunctionPCIDevNo INTEGER,
adapterNetworkFunctionPCIFuncNo INTEGER,
adapterNetworkFunctionPCIVendorId DisplayString,
adapterNetworkFunctionPCIDevId DisplayString,
adapterNetworkFunctionPCIDevType DisplayString,
adapterNetworkFunctionPCIRevId DisplayString,
adapterNetworkFunctionPCISubVendorId DisplayString,
adapterNetworkFunctionPCISubDevId DisplayString,
adapterNetworkFunctionPCISlotDesignation DisplayString
}
adapterNetworkFunctionIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular network function."
::= { adapterNetworkFunctionEntry 1 }
adapterNetworkFunctionNetworkVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name and PFA of a particular network function and PFA is in HEX."
::= { adapterNetworkFunctionEntry 2 }
adapterNetworkFunctionAdapterVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX."
::= { adapterNetworkFunctionEntry 3 }
adapterNetworkFunctionNetworkVPDManufacturer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Manufacturer of a particular network function."
::= { adapterNetworkFunctionEntry 4 }
adapterNetworkFunctionNetworkVPDUUID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The UUID of a particular network function."
::= { adapterNetworkFunctionEntry 5 }
adapterNetworkFunctionNetworkVPDModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Model of a particular network function."
::= { adapterNetworkFunctionEntry 6 }
adapterNetworkFunctionNetworkVPDSerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Serial No. of a particular network function."
::= { adapterNetworkFunctionEntry 7 }
adapterNetworkFunctionNetworkVPDFRUNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The FRU No. of a particular network function."
::= { adapterNetworkFunctionEntry 8 }
adapterNetworkFunctionNetworkVPDPartNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Part No. of a particular network function."
::= { adapterNetworkFunctionEntry 9 }
adapterNetworkFunctionFoDUID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The FoD UID of a particular network function."
::= { adapterNetworkFunctionEntry 10 }
adapterNetworkFunctionSupportHotPlug OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates whether the network function supports hot plug."
::= { adapterNetworkFunctionEntry 11 }
adapterNetworkFunctionPhysicalPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Physical Port Number of a particular network function."
::= { adapterNetworkFunctionEntry 12 }
adapterNetworkFunctionMaxPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Max Port Number of a particular network function."
::= { adapterNetworkFunctionEntry 13 }
adapterNetworkFunctionPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Port Number of a particular network function."
::= { adapterNetworkFunctionEntry 14 }
adapterNetworkFunctionMaxDataWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Maximum Data Width in Gbps of a particular network funtion."
::= { adapterNetworkFunctionEntry 15 }
adapterNetworkFunctionPackageType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Package Type of a particular network function."
::= { adapterNetworkFunctionEntry 16 }
adapterNetworkFunctionPCIBusNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Bus No. of a particular network function."
::= { adapterNetworkFunctionEntry 17 }
adapterNetworkFunctionPCIDevNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Device No. of a particular network function."
::= { adapterNetworkFunctionEntry 18 }
adapterNetworkFunctionPCIFuncNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Function No. of a particular network function."
::= { adapterNetworkFunctionEntry 19 }
adapterNetworkFunctionPCIVendorId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Vendor ID of a particular network function."
::= { adapterNetworkFunctionEntry 20 }
adapterNetworkFunctionPCIDevId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Device ID of a particular network function."
::= { adapterNetworkFunctionEntry 21 }
adapterNetworkFunctionPCIDevType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Device Type of a particular network function."
::= { adapterNetworkFunctionEntry 22 }
adapterNetworkFunctionPCIRevId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Revision ID of a particular network function."
::= { adapterNetworkFunctionEntry 23 }
adapterNetworkFunctionPCISubVendorId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Subsystem Vendor ID of a particular network function."
::= { adapterNetworkFunctionEntry 24 }
adapterNetworkFunctionPCISubDevId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Subsystem Device ID of a particular network function."
::= { adapterNetworkFunctionEntry 25 }
adapterNetworkFunctionPCISlotDesignation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Slot Designation of a particular network function."
::= { adapterNetworkFunctionEntry 26 }
-- *************************************************************************************
-- Physical Resource: The Port information of Network Function
-- ********************************************************************************
adapterNetworkPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdapterNetworkPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Ports of Network Function information."
::= { adapters 4 }
adapterNetworkPortEntry OBJECT-TYPE
SYNTAX AdapterNetworkPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ports of Network Function information entry."
INDEX { adapterNetworkPortIndex }
::= { adapterNetworkPortTable 1 }
AdapterNetworkPortEntry ::= SEQUENCE {
adapterNetworkPortIndex INTEGER,
adapterNetworkPortNetworkVPDProdName DisplayString,
adapterNetworkPortPhyPortNo INTEGER,
adapterNetworkPortPhyPortConnector DisplayString,
adapterNetworkPortPhyPortBurnedinAddress DisplayString,
adapterNetworkPortNo INTEGER,
adapterNetworkPortMaxDataSize Gauge,
adapterNetworkPortPermanentAddress DisplayString,
adapterNetworkPortNetworkAddress DisplayString,
adapterNetworkPortLinkTechnology DisplayString,
adapterNetworkPortvNICMode DisplayString,
adapterNetworkPortMaxSpeed DisplayString,
adapterNetworkPortProtocolType DisplayString,
adapterNetworkPortCurrentProtocol DisplayString,
adapterNetworkPortFCoEPermanentAddress DisplayString,
adapterNetworkPortFCoENetworkAddress DisplayString,
adapterNetworkPortConnectionType DisplayString,
adapterNetworkPortRole DisplayString,
adapterNetworkPortTargetRelativePortNo Gauge,
adapterNetworkPortPhyPortLinkStatus DisplayString,
adapterNetworkPortPhyPortLinkSpeed DisplayString
}
adapterNetworkPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular network port."
::= { adapterNetworkPortEntry 1 }
adapterNetworkPortNetworkVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name and PFA of the network function for this port and PFA is in HEX."
::= { adapterNetworkPortEntry 2 }
adapterNetworkPortPhyPortNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Physical Port No. in the network function for this port."
::= { adapterNetworkPortEntry 3 }
adapterNetworkPortPhyPortConnector OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Physical Port Connector Layout in the network function for this port."
::= { adapterNetworkPortEntry 4 }
adapterNetworkPortPhyPortBurnedinAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Physical Permanent (burned-In) Address of a particular network port."
::= { adapterNetworkPortEntry 5 }
adapterNetworkPortNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Port No. of this network port in the network function."
::= { adapterNetworkPortEntry 6 }
adapterNetworkPortMaxDataSize OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Port Max Data Size of this network port in the network function."
::= { adapterNetworkPortEntry 7 }
adapterNetworkPortPermanentAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Permanent Address of a particular network port."
::= { adapterNetworkPortEntry 8 }
adapterNetworkPortNetworkAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Network Address of a particular network port."
::= { adapterNetworkPortEntry 9 }
adapterNetworkPortLinkTechnology OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Link Technology of a particular network port."
::= { adapterNetworkPortEntry 10 }
adapterNetworkPortvNICMode OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "If the logical port vNIC mode is Virtual Fabric mode, Switch Independent mode,
or Unified Fabric Protocol mode, this column returns 1(enabled), otherwise, the columen
returns 0(disabled)"
::= { adapterNetworkPortEntry 11 }
adapterNetworkPortMaxSpeed OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Maximum Bandwidth in Gbps of a particular network port."
::= { adapterNetworkPortEntry 12 }
adapterNetworkPortProtocolType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Protocol Type of a particular network port."
::= { adapterNetworkPortEntry 13 }
adapterNetworkPortCurrentProtocol OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Current Work Protocol of a particular network port."
::= { adapterNetworkPortEntry 14 }
adapterNetworkPortFCoEPermanentAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The FCoE Permanent Address of a particular network port."
::= { adapterNetworkPortEntry 15 }
adapterNetworkPortFCoENetworkAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The FCoE Network Address of a particular network port."
::= { adapterNetworkPortEntry 16 }
adapterNetworkPortConnectionType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Connection Type of a particular network port if its current work protocol is FC or FCoE."
::= { adapterNetworkPortEntry 17 }
adapterNetworkPortRole OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Port Role of a particular network port if its current work protocol is FC or FCoE."
::= { adapterNetworkPortEntry 18 }
adapterNetworkPortTargetRelativePortNo OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Target Relative Port No. of a particular network port if its current work protocol is FC or FCoE."
::= { adapterNetworkPortEntry 19 }
adapterNetworkPortPhyPortLinkStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION " The Physical Port Link Status in the network function for this port."
::= { adapterNetworkPortEntry 20 }
adapterNetworkPortPhyPortLinkSpeed OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION " The Physical Port Link Speed in the network function for this port. "
::= { adapterNetworkPortEntry 21 }
-- *************************************************************************************
-- Physical Resource: The properties of GPU Function information
-- ********************************************************************************
adapterGPUFunctionTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdapterGPUFunctionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of GPU Function information."
::= { adapters 5 }
adapterGPUFunctionEntry OBJECT-TYPE
SYNTAX AdapterGPUFunctionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"GPU function information entry."
INDEX { adapterGPUFunctionIndex }
::= { adapterGPUFunctionTable 1 }
AdapterGPUFunctionEntry ::= SEQUENCE {
adapterGPUFunctionIndex INTEGER,
adapterGPUFunctionGpuVPDProdName DisplayString,
adapterGPUFunctionAdapterVPDProdName DisplayString,
adapterGPUFunctionGpuVPDManufacturer DisplayString,
adapterGPUFunctionGpuVPDUUID DisplayString,
adapterGPUFunctionGpuVPDModel DisplayString,
adapterGPUFunctionGpuVPDSerialNo DisplayString,
adapterGPUFunctionGpuVPDFRUNo DisplayString,
adapterGPUFunctionGpuVPDPartNo DisplayString,
adapterGPUFunctionFoDUID DisplayString,
adapterGPUFunctionSupportHotPlug INTEGER,
adapterGPUFunctionVideoMemorySize DisplayString,
adapterGPUFunctionVideoMemoryType DisplayString,
adapterGPUFunctionChipNumber INTEGER,
adapterGPUFunctionMaxDataWidth INTEGER,
adapterGPUFunctionPackageType DisplayString,
adapterGPUFunctionPCIBusNo INTEGER,
adapterGPUFunctionPCIDevNo INTEGER,
adapterGPUFunctionPCIFuncNo INTEGER,
adapterGPUFunctionPCIVendorId DisplayString,
adapterGPUFunctionPCIDevId DisplayString,
adapterGPUFunctionPCIDevType DisplayString,
adapterGPUFunctionPCIRevId DisplayString,
adapterGPUFunctionPCISubVendorId DisplayString,
adapterGPUFunctionPCISubDevId DisplayString,
adapterGPUFunctionPCISlotDesignation DisplayString
}
adapterGPUFunctionIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular GPU function."
::= { adapterGPUFunctionEntry 1 }
adapterGPUFunctionGpuVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name and PFA of a particular GPU function and PFA is in HEX."
::= { adapterGPUFunctionEntry 2 }
adapterGPUFunctionAdapterVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX."
::= { adapterGPUFunctionEntry 3 }
adapterGPUFunctionGpuVPDManufacturer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Manufacturer of a particular GPU function."
::= { adapterGPUFunctionEntry 4 }
adapterGPUFunctionGpuVPDUUID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The UUID of a particular GPU function."
::= { adapterGPUFunctionEntry 5 }
adapterGPUFunctionGpuVPDModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Model of a particular GPU function."
::= { adapterGPUFunctionEntry 6 }
adapterGPUFunctionGpuVPDSerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Serial No. of a particular GPU function."
::= { adapterGPUFunctionEntry 7 }
adapterGPUFunctionGpuVPDFRUNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The FRU No. of a particular GPU function."
::= { adapterGPUFunctionEntry 8 }
adapterGPUFunctionGpuVPDPartNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Part No. of a particular GPU function."
::= { adapterGPUFunctionEntry 9 }
adapterGPUFunctionFoDUID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The FoD UID of a particular GPU function."
::= { adapterGPUFunctionEntry 10 }
adapterGPUFunctionSupportHotPlug OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates whether the GPU function supports hot plug."
::= { adapterGPUFunctionEntry 11 }
adapterGPUFunctionVideoMemorySize OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Video Memory Size of a particular GPU function."
::= { adapterGPUFunctionEntry 12 }
adapterGPUFunctionVideoMemoryType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Video Memory Type of a particular GPU function."
::= { adapterGPUFunctionEntry 13 }
adapterGPUFunctionChipNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Chip Number of a particular GPU function."
::= { adapterGPUFunctionEntry 14 }
adapterGPUFunctionMaxDataWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Maximum Data Width in Gbps of a particular GPU funtion."
::= { adapterGPUFunctionEntry 15 }
adapterGPUFunctionPackageType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Package Type of a particular GPU function."
::= { adapterGPUFunctionEntry 16 }
adapterGPUFunctionPCIBusNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Bus No. of a particular GPU function."
::= { adapterGPUFunctionEntry 17 }
adapterGPUFunctionPCIDevNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Device No. of a particular GPU function."
::= { adapterGPUFunctionEntry 18 }
adapterGPUFunctionPCIFuncNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Function No. of a particular GPU function."
::= { adapterGPUFunctionEntry 19 }
adapterGPUFunctionPCIVendorId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Vendor ID of a particular GPU function."
::= { adapterGPUFunctionEntry 20 }
adapterGPUFunctionPCIDevId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Device ID of a particular GPU function."
::= { adapterGPUFunctionEntry 21 }
adapterGPUFunctionPCIDevType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Device Type of a particular GPU function."
::= { adapterGPUFunctionEntry 22 }
adapterGPUFunctionPCIRevId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Revision ID of a particular GPU function."
::= { adapterGPUFunctionEntry 23 }
adapterGPUFunctionPCISubVendorId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Subsystem Vendor ID of a particular GPU function."
::= { adapterGPUFunctionEntry 24 }
adapterGPUFunctionPCISubDevId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Subsystem Device ID of a particular GPU function."
::= { adapterGPUFunctionEntry 25 }
adapterGPUFunctionPCISlotDesignation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Slot Designation of a particular GPU function."
::= { adapterGPUFunctionEntry 26 }
-- *************************************************************************************
-- Physical Resource: The Chip information of GPU function
-- ********************************************************************************
adapterGPUChipTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdapterGPUChipEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Chips of GPU Function information."
::= { adapters 6 }
adapterGPUChipEntry OBJECT-TYPE
SYNTAX AdapterGPUChipEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"GPU function chip information entry."
INDEX { adapterGPUChipIndex }
::= { adapterGPUChipTable 1 }
AdapterGPUChipEntry ::= SEQUENCE {
adapterGPUChipIndex INTEGER,
adapterGPUChipGpuVPDProdName DisplayString,
adapterGPUChipNo INTEGER,
adapterGPUChipName DisplayString,
adapterGPUChipFamily DisplayString,
adapterGPUChipManufacturer DisplayString,
adapterGPUChipCoresEnabled INTEGER,
adapterGPUChipMaxClockSpeed Gauge,
adapterGPUChipExtBusClockSpeed Gauge,
adapterGPUChipAddressWidth INTEGER,
adapterGPUChipDataWidth INTEGER,
adapterGPUChipFormFactor DisplayString,
adapterGPUChipModel DisplayString,
adapterGPUChipSerialNo DisplayString,
adapterGPUChipFRUNo DisplayString,
adapterGPUChipPartNo DisplayString,
adapterGPUChipUniqueID DisplayString
}
adapterGPUChipIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular GPU chip"
::= { adapterGPUChipEntry 1 }
adapterGPUChipGpuVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name and PFA of the GPU function for this chip and PFA is in HEX."
::= { adapterGPUChipEntry 2 }
adapterGPUChipNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Index of the GPU chip in the GPU adapter."
::= { adapterGPUChipEntry 3 }
adapterGPUChipName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Name of a particular GPU chip."
::= { adapterGPUChipEntry 4 }
adapterGPUChipFamily OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Family Name of a particular GPU chip."
::= { adapterGPUChipEntry 5 }
adapterGPUChipManufacturer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Manufacturer of a particular GPU chip."
::= { adapterGPUChipEntry 6 }
adapterGPUChipCoresEnabled OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates whether enable cores of a particular GPU chip."
::= { adapterGPUChipEntry 7 }
adapterGPUChipMaxClockSpeed OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Maximum Clock Speed in MHz of a particular GPU chip."
::= { adapterGPUChipEntry 8 }
adapterGPUChipExtBusClockSpeed OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "The External Bus Clock Speed in MHz of a particular GPU chip."
::= { adapterGPUChipEntry 9 }
adapterGPUChipAddressWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Address Width of a particular GPU chip."
::= { adapterGPUChipEntry 10 }
adapterGPUChipDataWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Data Width of a particular GPU chip."
::= { adapterGPUChipEntry 11 }
adapterGPUChipFormFactor OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Form Factor of a particular GPU chip."
::= { adapterGPUChipEntry 12 }
adapterGPUChipModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Model of a particular GPU chip."
::= { adapterGPUChipEntry 13 }
adapterGPUChipSerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Serial No. of a particular GPU chip."
::= { adapterGPUChipEntry 14 }
adapterGPUChipFRUNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The FRU No. of a particular GPU chip."
::= { adapterGPUChipEntry 15 }
adapterGPUChipPartNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Part No. of a particular GPU chip."
::= { adapterGPUChipEntry 16 }
adapterGPUChipUniqueID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Unique ID of a particular GPU chip."
::= { adapterGPUChipEntry 17 }
-- *************************************************************************************
-- Physical Resource: The properties of RAID Function information
-- ********************************************************************************
adapterRAIDFunctionTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdapterRAIDFunctionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of RAID Function information."
::= { adapters 7 }
adapterRAIDFunctionEntry OBJECT-TYPE
SYNTAX AdapterRAIDFunctionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RAID function information entry."
INDEX { adapterRAIDFunctionIndex }
::= { adapterRAIDFunctionTable 1 }
AdapterRAIDFunctionEntry ::= SEQUENCE {
adapterRAIDFunctionIndex INTEGER,
adapterRAIDFunctionRaidVPDProdName DisplayString,
adapterRAIDFunctionAdapterVPDProdName DisplayString,
adapterRAIDFunctionRaidVPDManufacturer DisplayString,
adapterRAIDFunctionRaidVPDUUID DisplayString,
adapterRAIDFunctionRaidVPDModel DisplayString,
adapterRAIDFunctionRaidVPDSerialNo DisplayString,
adapterRAIDFunctionRaidVPDFRUNo DisplayString,
adapterRAIDFunctionRaidVPDPartNo DisplayString,
adapterRAIDFunctionFoDUID DisplayString,
adapterRAIDFunctionSupportHotPlug INTEGER,
adapterRAIDFunctionMaxDataWidth INTEGER,
adapterRAIDFunctionPackageType DisplayString,
adapterRAIDFunctionPCIBusNo INTEGER,
adapterRAIDFunctionPCIDevNo INTEGER,
adapterRAIDFunctionPCIFuncNo INTEGER,
adapterRAIDFunctionPCIVendorId DisplayString,
adapterRAIDFunctionPCIDevId DisplayString,
adapterRAIDFunctionPCIDevType DisplayString,
adapterRAIDFunctionPCIRevId DisplayString,
adapterRAIDFunctionPCISubVendorId DisplayString,
adapterRAIDFunctionPCISubDevId DisplayString,
adapterRAIDFunctionPCISlotDesignation DisplayString
}
adapterRAIDFunctionIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular RAID function."
::= { adapterRAIDFunctionEntry 1 }
adapterRAIDFunctionRaidVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name and PFA of a particular RAID function and PFA is in HEX."
::= { adapterRAIDFunctionEntry 2 }
adapterRAIDFunctionAdapterVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX."
::= { adapterRAIDFunctionEntry 3 }
adapterRAIDFunctionRaidVPDManufacturer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Manufacturer of a particular RAID function."
::= { adapterRAIDFunctionEntry 4 }
adapterRAIDFunctionRaidVPDUUID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The UUID of a particular RAID function."
::= { adapterRAIDFunctionEntry 5 }
adapterRAIDFunctionRaidVPDModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Model of a particular RAID function."
::= { adapterRAIDFunctionEntry 6 }
adapterRAIDFunctionRaidVPDSerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Serial No. of a particular RAID function."
::= { adapterRAIDFunctionEntry 7 }
adapterRAIDFunctionRaidVPDFRUNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The FRU No. of a particular RAID function."
::= { adapterRAIDFunctionEntry 8 }
adapterRAIDFunctionRaidVPDPartNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Part No. of a particular RAID function."
::= { adapterRAIDFunctionEntry 9 }
adapterRAIDFunctionFoDUID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The FoD UID of a particular RAID function."
::= { adapterRAIDFunctionEntry 10 }
adapterRAIDFunctionSupportHotPlug OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates whether the RAID function supports hot plug."
::= { adapterRAIDFunctionEntry 11 }
adapterRAIDFunctionMaxDataWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Maximum Data Width in Gbps of a particular RAID funtion."
::= { adapterRAIDFunctionEntry 12 }
adapterRAIDFunctionPackageType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Package Type of a particular RAID function."
::= { adapterRAIDFunctionEntry 13 }
adapterRAIDFunctionPCIBusNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Bus No. of a particular RAID function."
::= { adapterRAIDFunctionEntry 14 }
adapterRAIDFunctionPCIDevNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Device No. of a particular RAID function."
::= { adapterRAIDFunctionEntry 15 }
adapterRAIDFunctionPCIFuncNo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Function No. of a particular RAID function."
::= { adapterRAIDFunctionEntry 16 }
adapterRAIDFunctionPCIVendorId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Vendor ID of a particular RAID function."
::= { adapterRAIDFunctionEntry 17 }
adapterRAIDFunctionPCIDevId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Device ID of a particular RAID function."
::= { adapterRAIDFunctionEntry 18 }
adapterRAIDFunctionPCIDevType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Device Type of a particular RAID function."
::= { adapterRAIDFunctionEntry 19 }
adapterRAIDFunctionPCIRevId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Revision ID of a particular RAID function."
::= { adapterRAIDFunctionEntry 20 }
adapterRAIDFunctionPCISubVendorId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Subsystem Vendor ID of a particular RAID function."
::= { adapterRAIDFunctionEntry 21 }
adapterRAIDFunctionPCISubDevId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Subsystem Device ID of a particular RAID function."
::= { adapterRAIDFunctionEntry 22 }
adapterRAIDFunctionPCISlotDesignation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PCI Slot Designation of a particular RAID function."
::= { adapterRAIDFunctionEntry 23 }
-- *************************************************************************************
-- Firmware Information: The properties of PCI function firmware information
-- ********************************************************************************
adapterFirmwareTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdapterFirmwareEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of PCI Function Firmware information."
::= { adapters 8 }
adapterFirmwareEntry OBJECT-TYPE
SYNTAX AdapterFirmwareEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Adapter Firmware Entry."
INDEX { adapterFwIndex }
::= { adapterFirmwareTable 1 }
AdapterFirmwareEntry ::= SEQUENCE {
adapterFwIndex INTEGER,
adapterFwFunctionVPDProdName DisplayString,
adapterFwName DisplayString,
adapterFwClassification DisplayString,
adapterFwDescription DisplayString,
adapterFwManufacture DisplayString,
adapterFwVersion DisplayString,
adapterFwReleaseDate DisplayString,
adapterFwSoftwareID DisplayString
}
adapterFwIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This column is used to identify a particular function firmware."
::= { adapterFirmwareEntry 1 }
adapterFwFunctionVPDProdName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Product Name and PFA of a particular function for this firmware and PFA is in HEX."
::= { adapterFirmwareEntry 2 }
adapterFwName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The name of a particular PCI function firmware."
::= { adapterFirmwareEntry 3 }
adapterFwClassification OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The classification of a particular PCI function firmware."
::= { adapterFirmwareEntry 4 }
adapterFwDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The description of a particular PCI function firmware."
::= { adapterFirmwareEntry 5 }
adapterFwManufacture OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The manufacturer of a particular PCI function firmware."
::= { adapterFirmwareEntry 6 }
adapterFwVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The version of a particular PCI function firmware."
::= { adapterFirmwareEntry 7 }
adapterFwReleaseDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The release date of a particular PCI function firmware."
::= { adapterFirmwareEntry 8 }
adapterFwSoftwareID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Software ID of a particular PCI function firmware."
::= { adapterFirmwareEntry 9 }
-- ***********************************************************************
-- Event Log Information
-- ***********************************************************************
eventLog OBJECT IDENTIFIER ::= { errorLogs 1 }
eventLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of event logs. View as a table and not as individual entries
for consistent results."
::= { eventLog 1 }
eventLogEntry OBJECT-TYPE
SYNTAX EventLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Event log entries. View as a table and not as individual entries for
consistent results."
INDEX { eventLogIndex }
::= { eventLogTable 1 }
EventLogEntry ::= SEQUENCE {
eventLogIndex INTEGER,
eventLogString OCTET STRING,
eventLogSeverity INTEGER,
eventLogDate OCTET STRING,
eventLogTime OCTET STRING
}
eventLogIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Event log index number. View as a table and not as individual entries for
consistent results."
::= { eventLogEntry 1 }
eventLogString OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains a string of information to detail the event. View as a table and
not as individual entries for consistent results."
::= { eventLogEntry 2}
eventLogSeverity OBJECT-TYPE
SYNTAX INTEGER{
error(0),
warning(1),
information(2),
other(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains a information to detail the severity of the event. View as a table and
not as individual entries for consistent results."
::= { eventLogEntry 3}
eventLogDate OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Date of the Event occured. View as a table and
not as individual entries for consistent results."
::= { eventLogEntry 4}
eventLogTime OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Time of the Event occured. View as a table and
not as individual entries for consistent results."
::= { eventLogEntry 5}
-- ***********************************************************************
-- Configure the XCC
-- ***********************************************************************
-- ***********************************************************************
-- Remote Access Configuration
-- ***********************************************************************
remoteAccessConfig OBJECT IDENTIFIER ::= { configureSP 1 }
-- ***********************************************************************
-- General Remote Access and Remote Alerts Configuration
-- ***********************************************************************
generalRemoteCfg OBJECT IDENTIFIER ::= { remoteAccessConfig 1 }
remoteAlertRetryDelay OBJECT-TYPE
SYNTAX INTEGER {
noDelay(0),
oneHalfMinute(30),
oneMinute(60),
oneAndHalfMinutes(90),
twoMinutes(120),
twoAndHalfMinutes(150),
threeMinutes(180),
threeAndHalfMinutes(210),
fourMinutes(240)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number in seconds to delay between retries if sending a
remote alert is unsuccessful."
::= { generalRemoteCfg 1 }
remoteAlertRetryCount OBJECT-TYPE
SYNTAX INTEGER {
noretry(0),
retry1(1),
retry2(2),
retry3(3),
retry4(4),
retry5(5),
retry6(6),
retry7(7),
retry8(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of additional times a remote alert will be
retried if not succesfully sent. A value of zero indicates
no retries will be attempted."
::= { generalRemoteCfg 2 }
remoteAlertEntryDelay OBJECT-TYPE
SYNTAX INTEGER {
noDelay(0),
oneHalfMinute(30),
oneMinute(60),
oneAndHalfMinutes(90),
twoMinutes(120),
twoAndHalfMinutes(150),
threeMinutes(180),
threeAndHalfMinutes(210),
fourMinutes(240)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number in seconds to delay between entries if sending a
remote alert is unsuccessful."
::= { generalRemoteCfg 3 }
snmpCriticalAlerts OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If Enabled,criticalAlerts will be sent to
SNMP, else critical alerts will not be sent."
::= { generalRemoteCfg 4 }
snmpWarningAlerts OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If Enabled,warningAlerts will be sent to
SNMP , else warning alerts will not be sent."
::= { generalRemoteCfg 5 }
snmpSystemAlerts OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If Enabled,systemAlerts will be sent to
SNMP , else system alerts will not be sent."
::= { generalRemoteCfg 6 }
remoteAccessTamperDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number in minutes to prohibit a remote login attempt after more than maximum login attempts have failed. The minimum value is 0 and the maximum value is 2880 minute. The default value is 60 minutes."
::= { generalRemoteCfg 7 }
userAuthenticationMethod OBJECT-TYPE
SYNTAX INTEGER {
localOnly(0),
ldapOnly(1),
localFirstThenLdap(2),
ldapFirstThenLocal(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Use this field to specify how users attempting to login should be authenticated.
There are two methods:
Local authentication. Userid and password are verified by searching the list
of users locally configured under Local Login Profiles.
LDAP based authentication. Users are authenticated via a remote LDAP server.
One or both authentication methods can be selected. If both methods should be
used, the order must be specified."
::= { generalRemoteCfg 8 }
webInactivityTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of time, in minutes, that a user session established with the management server can be inactive before the user is logged out. The minimum value is 0 and the maximum value is 1440 minutes. The default value is 20 minutes. If the value is 0, web session never expire."
::= { generalRemoteCfg 9 }
-- ***********************************************************************
-- SNMP alert filters
-- ***********************************************************************
snmpAlertFilters OBJECT IDENTIFIER ::= { generalRemoteCfg 10 }
safSpTrapTempC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Temperature threshold exceeded."
::= { snmpAlertFilters 2 }
safSpTrapVoltC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Voltage threshold exceeded."
::= { snmpAlertFilters 3 }
safSpTrapPowerC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Power failure."
::= { snmpAlertFilters 4 }
safSpTrapHdC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Hard disk drive failure."
::= { snmpAlertFilters 5 }
safSpTrapFanC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Single Fan failure."
::= { snmpAlertFilters 6 }
safSpTrapIhcC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Incompatible hardware configuration."
::= { snmpAlertFilters 7 }
safSpTrapCPUC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: CPU Error."
::= { snmpAlertFilters 8 }
safSpTrapMemoryC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Memory Error."
::= { snmpAlertFilters 9 }
safSpTrapRdpsC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Redundant Power Supply failure."
::= { snmpAlertFilters 10 }
safSpTrapHardwareC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Other Failure - refer to Message ID for specific condition."
::= { snmpAlertFilters 11 }
safSpTrapRdpsN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Redundant Power Supply failure."
::= { snmpAlertFilters 12 }
safSpTrapTempN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Temperature threshold exceeded."
::= { snmpAlertFilters 13 }
safSpTrapVoltN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Voltage threshold exceeded."
::= { snmpAlertFilters 14 }
safSpTrapPowerN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Power."
::= { snmpAlertFilters 15 }
safSpTrapFanN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Fan Error."
::= { snmpAlertFilters 16 }
safSpTrapCPUN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Memory Error."
::= { snmpAlertFilters 17 }
safSpTrapMemoryN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Memory Error."
::= { snmpAlertFilters 18 }
safSpTrapHardwareN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Warning - refer to Message ID for specific condition."
::= { snmpAlertFilters 19 }
safSpTrapRLogin OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sev-Off Alert: Event Remote Login."
::= { snmpAlertFilters 20 }
safSpTrapOsToS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: OS Timeout value exceeded."
::= { snmpAlertFilters 21 }
safSpTrapAppS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: Application Alert. Refer to Message ID for specific condition."
::= { snmpAlertFilters 22 }
safSpTrapPowerS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: Power on or off." -- Off only for XCC
::= { snmpAlertFilters 23 }
safSpTrapBootS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: System Boot Failure."
::= { snmpAlertFilters 24 }
safSpTrapLdrToS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: OS Loader Timeout."
::= { snmpAlertFilters 25 }
safSpTrapPFAS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: Predictive Failure Analysis(PFA) information."
::= { snmpAlertFilters 26 }
safSpTrapSysLogS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: System Log 75% full."
::= { snmpAlertFilters 27 }
safSpTrapNwChangeS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: Network change notification."
::= { snmpAlertFilters 28 }
-- ***********************************************************************
-- begin account security management
-- ***********************************************************************
customSecuritySettings OBJECT IDENTIFIER ::= { generalRemoteCfg 20 }
passwordExpirationWarningPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of time, in days, before password expiration that users will begin to receive warnings about the impending expiration of the user password. The minimum value is 0 and the maximum value is the maximum password expiration period. The default value is 5 days. A value of 0 means that the users are never warned."
::= { customSecuritySettings 1 }
passwordExpirationPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of time, in days, that a user may use a password before it must be changed. Smaller values reduce the amount of time for attackers to guess passwords. The minimum value is 0 and the maximum value is 365 days. The default value is 90 days. A value of 0 means that the password never expire."
::= { customSecuritySettings 2 }
minimumPasswordReuseCycle OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum number of the times that a user must enter a unique password before the user can start to reuse passwords. A higher number enhances security. The minimum value is 0 and the maximum value is 10 times. The default value is 5 times. A value of 0 means that passwords may be reused immediately."
::= { customSecuritySettings 3 }
minimumPasswordLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum number of characters that can be used to specify a valid password. The minimum value is 8 characters and the maximum value is 20 characters. The default value is 8 characters."
::= { customSecuritySettings 5 }
defaultAdminPasswordExpired OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value of 1 means that the factory default 'USERID' account password must be changed on next login. A value of 0 means that there is no such requirement. The default value is 0."
::= { customSecuritySettings 6 }
changePasswordFirstAccess OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value of 1 means that a user is required to change the password when the user logs in to the management server for the first time. A value of 0 means no such requirment. The default value is 1."
::= { customSecuritySettings 8 }
accountLockoutPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum about of time, in minutes, that must pass before a user that was locked out can attempt to log back in again. The minimum value is 0 and the maximum value is 2880 minutes. The default value is 60 minutes. A value of 0 can make your system more exposed to serious denial of service attacks, where deliberate failed login attempts can leave accounts permanently locked."
::= { customSecuritySettings 9 }
maxLoginFailures OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of times that a user can attempt to log in with an incorrect password before the user account is locked out. The number specified for the lockout period after maximum login failures determines how long the user account is locked out. Accounts that are locked cannot be used to gain access to the system even if a valid password is provided. The maximum value is 10 times. The default value is 5 times. A value of 0 means that accounts are never locked."
::= { customSecuritySettings 10 }
passwordChangeInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum about of time, in hours, that must elapse before a user may change a password again after it has been changed once. The value specified for this setting would not exceed the value specified for the password expiration period. A small value allows users to more quickly use old passwords. The range of acceptable values will be from 0 to 240 hours. The default value is 24 hours. If the value is 0, passwords may be changed immediately. "
::= { customSecuritySettings 11 }
-- ***********************************************************************
-- XCC Serial Port Configuration
-- ***********************************************************************
serialPortCfg OBJECT IDENTIFIER ::= { remoteAccessConfig 2 }
portBaud OBJECT-TYPE -- XCC-only
SYNTAX INTEGER {
baud9600(3),
baud19200(4),
baud38400(5),
baud57600(6),
baud115200(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Baud rate for the serial port."
::= { serialPortCfg 1 }
portParity OBJECT-TYPE -- XCC-only
SYNTAX INTEGER {
none(0),
odd(1),
even(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Parity setting for the serial port."
::= { serialPortCfg 2 }
-- ***********************************************************************
-- Serial Redirect
-- ***********************************************************************
serialRedirect OBJECT IDENTIFIER ::= { serialPortCfg 3 }
enterCLIkeySeq OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the keystroke sequence used to enter the CLI.
This sequence must have at least one character. The caret symbol (^)
has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that
map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage
return). All ocurrences of ^ will be interpreted as part of a Ctrl sequence.
Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences.
The default value for this field is '^[(' i.e. ESC followed by (."
::= { serialRedirect 1 }
portStopBits OBJECT-TYPE
SYNTAX INTEGER {
oneStopbit(0),
twoOrOnePtFive(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of stop bits for the serial port."
::= { serialPortCfg 4 }
portCLImode OBJECT-TYPE
SYNTAX INTEGER {
cliDisable(0),
cliWithEMScompatibleKeystrokeSeq(1),
cliWithUserDefinedKeystrokeSeq(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Use this field to select the CLI (command line interface) mode for this port.
The CLI mode disablies serial redirect, or pecifies the type of keystroke
sequences to use for entering (returning to) the CLI from the system console."
::= { serialPortCfg 18 }
-- ***********************************************************************
-- Remote Alert Profiles
-- ***********************************************************************
remoteAlertIds OBJECT IDENTIFIER ::= { remoteAccessConfig 3 }
remoteAlertIdsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RemoteAlertIdsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of remote alert entries.
This table lets you configure remote alert recipients.
You can define up to 12 unique recipients. "
::= { remoteAlertIds 1 }
remoteAlertIdsEntry OBJECT-TYPE
SYNTAX RemoteAlertIdsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote alert entries."
INDEX { remoteAlertIdEntryIndex }
::= { remoteAlertIdsTable 1 }
RemoteAlertIdsEntry ::= SEQUENCE {
remoteAlertIdEntryIndex INTEGER,
remoteAlertIdEntryStatus INTEGER,
remoteAlertIdEntryName OCTET STRING,
remoteAlertIdEmailAddr OCTET STRING,
remoteAlertIdEntryCriticalAlert INTEGER,
remoteAlertIdEntryWarningAlert INTEGER,
remoteAlertIdEntrySystemAlert INTEGER,
remoteAlertIdEntryAuditAlert INTEGER,
remoteAlertIdEntryAttachmentsToEmailAlerts INTEGER,
remoteAlertIdEntrySyslogPortAssignment INTEGER,
remoteAlertIdEntrySyslogHostname OCTET STRING,
remoteAlertIdEntryType INTEGER -- XCC-only
}
remoteAlertIdEntryIndex OBJECT-TYPE
SYNTAX INTEGER (1..10000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for remote alert entry."
::= { remoteAlertIdsEntry 1 }
remoteAlertIdEntryStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If enabled alerts will be sent to this alert
recipient else alerts will not be sent."
::= { remoteAlertIdsEntry 2 }
remoteAlertIdEntryName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..50))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A null terminated string that contains
a text description of this entry."
::= { remoteAlertIdsEntry 3 }
remoteAlertIdEmailAddr OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..320)) -- XCC limited to 64
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A null terminated string that
contains a E-Mail Address. For example 'jeb@us.lenovo.com'.
Used only for a E-mail over Lan."
::= { remoteAlertIdsEntry 4}
remoteAlertIdEntryCriticalAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If Enabled,criticalAlerts will be sent to this
remote alert receipient,else critical alerts will not be sent."
::= { remoteAlertIdsEntry 5 }
remoteAlertIdEntryWarningAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If Enabled,warningAlerts will be sent to this
remote alert receipient,else warningAlerts will not be sent."
::= { remoteAlertIdsEntry 6 }
remoteAlertIdEntrySystemAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If Enabled,systemAlerts will be sent to this
remote alert receipient,else systemAlerts will not be sent."
::= { remoteAlertIdsEntry 7 }
remoteAlertIdEntryAuditAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If Enabled,systemAlerts will be sent to this
remote alert receipient,else systemAlerts will not be sent."
::= { remoteAlertIdsEntry 8 }
remoteAlertIdEntryAttachmentsToEmailAlerts OBJECT-TYPE
SYNTAX INTEGER {
noAttachments(0),
attachEventLog(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates if the event log should be attached to
a email alert."
::= { remoteAlertIdsEntry 9 }
remoteAlertIdEntrySyslogPortAssignment OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Syslog port number."
::= { remoteAlertIdsEntry 10 }
remoteAlertIdEntrySyslogHostname OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Syslog hostname or IP address."
::= { remoteAlertIdsEntry 11 }
remoteAlertIdEntryType OBJECT-TYPE
SYNTAX INTEGER {
email(1),
syslog(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alert recipient type."
::= { remoteAlertIdsEntry 12 }
remoteAlertFiltersTable OBJECT-TYPE
SYNTAX SEQUENCE OF RemoteAlertFiltersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Alert Filters. The entries (rows) in this table correspond 1-1 with the entries in the
remoteAlertIdsTable. They are correlated by index. "
::= { remoteAlertIds 2 }
remoteAlertFiltersEntry OBJECT-TYPE
SYNTAX RemoteAlertFiltersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Filters entries."
INDEX { rafIndex }
::= { remoteAlertFiltersTable 1 }
RemoteAlertFiltersEntry ::= SEQUENCE {
rafIndex INTEGER(0..255),
rafSpTrapTempC INTEGER,
rafSpTrapVoltC INTEGER,
rafSpTrapPowerC INTEGER,
rafSpTrapHdC INTEGER,
rafSpTrapFanC INTEGER,
rafSpTrapIhcC INTEGER,
rafSpTrapCPUC INTEGER,
rafSpTrapMemoryC INTEGER,
rafSpTrapRdpsC INTEGER,
rafSpTrapHardwareC INTEGER,
rafSpTrapRdpsN INTEGER,
rafSpTrapTempN INTEGER,
rafSpTrapVoltN INTEGER,
rafSpTrapPowerN INTEGER,
rafSpTrapFanN INTEGER,
rafSpTrapCPUN INTEGER,
rafSpTrapMemoryN INTEGER,
rafSpTrapHardwareN INTEGER,
rafSpTrapRLogin INTEGER,
rafSpTrapOsToS INTEGER,
rafSpTrapAppS INTEGER,
rafSpTrapPowerS INTEGER,
rafSpTrapBootS INTEGER,
rafSpTrapLdrToS INTEGER,
rafSpTrapPFAS INTEGER,
rafSpTrapSysLogS INTEGER,
rafSpTrapNwChangeS INTEGER,
rafSpTrapAllAuditS INTEGER
}
rafIndex OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for User Authority Level entry."
::= { remoteAlertFiltersEntry 1 }
rafSpTrapTempC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Temperature threshold exceeded."
::= { remoteAlertFiltersEntry 2 }
rafSpTrapVoltC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Voltage threshold exceeded."
::= { remoteAlertFiltersEntry 3 }
rafSpTrapPowerC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Power failure."
::= { remoteAlertFiltersEntry 4 }
rafSpTrapHdC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Hard disk drive failure."
::= { remoteAlertFiltersEntry 5 }
rafSpTrapFanC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Single Fan failure."
::= { remoteAlertFiltersEntry 6 }
rafSpTrapIhcC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Incompatible hardware configuration."
::= { remoteAlertFiltersEntry 7 }
rafSpTrapCPUC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: CPU Error."
::= { remoteAlertFiltersEntry 8 }
rafSpTrapMemoryC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Memory Error."
::= { remoteAlertFiltersEntry 9 }
rafSpTrapRdpsC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Redundant Power Supply failure."
::= { remoteAlertFiltersEntry 10 }
rafSpTrapHardwareC OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Critical Alert: Other Failure - refer to Message ID for specific condition."
::= { remoteAlertFiltersEntry 11 }
rafSpTrapRdpsN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Redundant Power Supply failure."
::= { remoteAlertFiltersEntry 12 }
rafSpTrapTempN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Temperature threshold exceeded."
::= { remoteAlertFiltersEntry 13 }
rafSpTrapVoltN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Voltage threshold exceeded."
::= { remoteAlertFiltersEntry 14 }
rafSpTrapPowerN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Power."
::= { remoteAlertFiltersEntry 15 }
rafSpTrapFanN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Fan Error."
::= { remoteAlertFiltersEntry 16 }
rafSpTrapCPUN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Memory Error."
::= { remoteAlertFiltersEntry 17 }
rafSpTrapMemoryN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Memory Error."
::= { remoteAlertFiltersEntry 18 }
rafSpTrapHardwareN OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Non-Critical Alert: Warning - refer to Message ID for specific condition."
::= { remoteAlertFiltersEntry 19 }
rafSpTrapRLogin OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sev-Off Alert: Event Remote Login."
::= { remoteAlertFiltersEntry 20 }
rafSpTrapOsToS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: OS Timeout value exceeded."
::= { remoteAlertFiltersEntry 21 }
rafSpTrapAppS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: Application Alert. Refer to Message ID for specific condition."
::= { remoteAlertFiltersEntry 22 }
rafSpTrapPowerS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: Power On or Off."
::= { remoteAlertFiltersEntry 23 }
rafSpTrapBootS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: System Boot Failure."
::= { remoteAlertFiltersEntry 24 }
rafSpTrapLdrToS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: OS Loader Timeout."
::= { remoteAlertFiltersEntry 25 }
rafSpTrapPFAS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: Predictive Failure Analysis(PFA) information."
::= { remoteAlertFiltersEntry 26 }
rafSpTrapSysLogS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: System Log 75% full."
::= { remoteAlertFiltersEntry 27 }
rafSpTrapNwChangeS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: Network change notification."
::= { remoteAlertFiltersEntry 28 }
rafSpTrapAllAuditS OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Alert: All Audit Events notification."
::= { remoteAlertFiltersEntry 29 }
-- ***********************************************************************
-- Remote Access Profiles
-- ***********************************************************************
remoteAccessIds OBJECT IDENTIFIER ::= { remoteAccessConfig 4 }
remoteAccessIdsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RemoteAccessIdsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of remote access profiles.
This table lets you to configure all login profiles.
You can define up to 12 unique profiles.
Note: By default, the remote supervisor adapter
comes configured with one login profile that allows remote
access using a login ID of 'USERID' and a password of 'PASSW0RD'
(the 0 is a zero). To avoid a potential security exposure,
we strongly recommend that you change this default Login
Profile to values of your choice."
::= { remoteAccessIds 1 }
remoteAccessIdsEntry OBJECT-TYPE
SYNTAX RemoteAccessIdsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote access entries."
INDEX { remoteAccessIdEntryIndex }
::= { remoteAccessIdsTable 1 }
RemoteAccessIdsEntry ::= SEQUENCE {
remoteAccessIdEntryIndex INTEGER,
remoteAccessIdEntryUserId OCTET STRING,
remoteAccessIdEntryUserPwdLeftDays INTEGER
}
remoteAccessIdEntryIndex OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for Remote access entry."
::= { remoteAccessIdsEntry 1 }
remoteAccessIdEntryUserId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote access entry null terminated string that contains the user-id. This can only be modified from blank to non-blank, then back to blank."
::= { remoteAccessIdsEntry 2 }
-- made part of user structure instead of separate structure
remoteAccessIdEntryUserPwdLeftDays OBJECT-TYPE
SYNTAX INTEGER(0..365)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"left days before password expired for selected user"
::= {remoteAccessIdsEntry 3 }
-- 51.1.4.1.4.2
remoteAccessUserAuthorityLevelTable OBJECT-TYPE
SYNTAX SEQUENCE OF RemoteAccessUserAuthorityLevelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of user authority level profiles."
::= { remoteAccessIds 2 }
remoteAccessUserAuthorityLevelEntry OBJECT-TYPE
SYNTAX RemoteAccessUserAuthorityLevelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User authority level entries."
INDEX { ualIndex }
::= { remoteAccessUserAuthorityLevelTable 1 }
RemoteAccessUserAuthorityLevelEntry ::= SEQUENCE {
ualIndex INTEGER(0..255),
ualId OCTET STRING (SIZE(0..16)),
ualSupervisor INTEGER,
ualReadOnly INTEGER,
ualAccountManagement INTEGER,
ualConsoleAccess INTEGER,
ualConsoleAndVirtualMediaAccess INTEGER,
ualServerPowerAccess INTEGER,
ualAllowClearLog INTEGER,
ualAdapterBasicConfig INTEGER,
ualAdapterNetworkAndSecurityConfig INTEGER,
ualAdapterAdvancedConfig INTEGER
}
ualIndex OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for User Authority Level entry."
::= { remoteAccessUserAuthorityLevelEntry 1 }
ualId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"User ID"
::= { remoteAccessUserAuthorityLevelEntry 2 }
ualSupervisor OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"User has no restrictions."
::= { remoteAccessUserAuthorityLevelEntry 3 }
ualReadOnly OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"User has only read-only access, and cannot perform any save, modify,
clear, or state affecting operations (eg. restart XCC, restore defaults,
upgrade the firmware, etc.)."
::= { remoteAccessUserAuthorityLevelEntry 4 }
ualAccountManagement OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"It is custom user authority level. User can add/modify/delete users and change the global login settings in the Login Profiles panel.
NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled."
::= { remoteAccessUserAuthorityLevelEntry 5 }
ualConsoleAccess OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"It is custom user authority level. User can access the remote console.
NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled."
::= { remoteAccessUserAuthorityLevelEntry 6 }
ualConsoleAndVirtualMediaAccess OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"It is custom user authority level. User can access both the remote console and the virtual media feature.
NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled."
::= { remoteAccessUserAuthorityLevelEntry 7 }
ualServerPowerAccess OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"It is custom user authority level. User can access the power on and restart functions for the remote server. These functions are available via the Power/Restart panel.
NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled."
::= { remoteAccessUserAuthorityLevelEntry 8 }
ualAllowClearLog OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"It is custom user authority level. User can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs.
NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled."
::= { remoteAccessUserAuthorityLevelEntry 9 }
ualAdapterBasicConfig OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"It is custom user authority level. User can modify configuration parameters in the System Settings and Alerts panels.
NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled."
::= { remoteAccessUserAuthorityLevelEntry 10 }
ualAdapterNetworkAndSecurityConfig OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"It is custom user authority level. User can modify configuration parameters in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels.
NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled."
::= { remoteAccessUserAuthorityLevelEntry 11 }
ualAdapterAdvancedConfig OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"It is custom user authority level. User has no restrictions when configuring the adapter. In addition, the user is said to have administrative access to the XCC, meaning that the user can also perform the following advanced functions: firmware upgrades, PXE network boot, restore adapter factory defaults, modify and restore
adapter configuration from a configuration file, and restart/reset the adapter.
NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled."
::= { remoteAccessUserAuthorityLevelEntry 12 }
-- ************************************************************************************
-- Group Profiles for LDAP Users
-- *************************************************************************************
groupProfiles OBJECT IDENTIFIER ::= { remoteAccessConfig 5 }
groupIdsTable OBJECT-TYPE
SYNTAX SEQUENCE OF GroupIdsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Group profiles.
This table lets you to configure all group profiles.
You can define up to 16 unique profiles."
::= { groupProfiles 1 }
groupIdsEntry OBJECT-TYPE
SYNTAX GroupIdsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Group ID entries."
INDEX { groupIndex }
::= { groupIdsTable 1 }
GroupIdsEntry ::= SEQUENCE {
groupIndex INTEGER,
groupId OCTET STRING,
groupRole OCTET STRING
}
groupIndex OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for Group IDs entry."
::= { groupIdsEntry 1 }
groupId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group ID. It is a null terminated string that contains the group-id.
It must not be a duplicate of any previously configured ones."
::= { groupIdsEntry 2 }
groupRole OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group Role. It indicates if the group has supervisor, operator,
or custom access."
::= { groupIdsEntry 3 }
groupRBSroleTable OBJECT-TYPE
SYNTAX SEQUENCE OF GroupRBSroleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Group Role profiles."
::= { groupProfiles 2 }
groupRBSroleEntry OBJECT-TYPE
SYNTAX GroupRBSroleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Group Role entries."
INDEX { groupRBSroleIndex }
::= { groupRBSroleTable 1 }
GroupRBSroleEntry ::= SEQUENCE {
groupRBSroleIndex INTEGER,
groupRBSroleId OCTET STRING,
groupRBSSupervisor INTEGER,
groupRBSOperator INTEGER,
groupRBSNetworkSecurity INTEGER,
groupRBSUserAccountManagement INTEGER,
groupRBSRemoteConsoleAccess INTEGER,
groupRBSRemoteConsoleRemoteDiskAccess INTEGER,
groupRBSServerPowerRestartAccess INTEGER,
groupRBSBasicAdapterConfiguration INTEGER,
groupRBSClearEventLog INTEGER,
groupRBSAdvancedAdapterConfiguration INTEGER
}
groupRBSroleIndex OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for Group Role entry."
::= { groupRBSroleEntry 1 }
groupRBSroleId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group ID"
::= { groupRBSroleEntry 2 }
groupRBSSupervisor OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group has no restrictions."
::= { groupRBSroleEntry 3 }
groupRBSOperator OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group has read-only access, and cannot perform
any save, modify, clear, or state affecting operations
(e.g. restart XCC, restore defaults, upgrade the firmware, etc.)."
::= { groupRBSroleEntry 4 }
groupRBSNetworkSecurity OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group can modify the configuration in the Security, Network Protocols,
Network Interface, Port Assignments, and Serial Port panels."
::= { groupRBSroleEntry 5 }
groupRBSUserAccountManagement OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group can add/modify/delete users and change the Global Login Settings
in the Login Profiles panel."
::= { groupRBSroleEntry 6 }
groupRBSRemoteConsoleAccess OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group can access the remote server console."
::= { groupRBSroleEntry 7 }
groupRBSRemoteConsoleRemoteDiskAccess OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group can access the remote server console and the remote disk functions
for the remote server."
::= { groupRBSroleEntry 8 }
groupRBSServerPowerRestartAccess OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group can access the power on, restart and server timeout functions for
the remote server."
::= { groupRBSroleEntry 9 }
groupRBSBasicAdapterConfiguration OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group can modify configuration parameters in the System Settings (excluding
Contact, Location and Server Timeouts) and Alerts panels."
::= { groupRBSroleEntry 10 }
groupRBSClearEventLog OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group can clear the event logs. Everyone can look at the event logs, but
this particular permission is required to clear the logs."
::= { groupRBSroleEntry 11 }
groupRBSAdvancedAdapterConfiguration OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Group has no restrictions when configuring the adapter. In addition the
user is said to have administrative access to the XCC, meaning that the user
can also perform the following advanced functions: firmware upgrades, PXE
network boot, restore adapter factory defaults, modify and restore adapter
configuration from a configuration file, and restart/reset the adapter. This
excludes Server Power/Restart Control and timeout functions."
::= { groupRBSroleEntry 12 }
-- ---------------------------------------------------------- --
-- The Remote Access ID SSH Client Authentication Public Key Group
-- ---------------------------------------------------------- --
sshClientAuth OBJECT IDENTIFIER ::= { remoteAccessConfig 6 }
sshClientAuthPubKeyTable OBJECT-TYPE
SYNTAX SEQUENCE OF SSHClientAuthPubKeyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains client authentication
public key information."
::= { sshClientAuth 1 }
sshClientAuthPubKeyEntry OBJECT-TYPE
SYNTAX SSHClientAuthPubKeyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A information list about a particular SSH
public key used for client authentication.
The primary table index is the same value as
the associated remoteAccessIdEntryIndex.
The secondary table index allows selection
of the Nth public key for that
remoteAccessIdEntryIndex."
INDEX { sshClientAuthRemoteAccessIdIndex ,
sshClientAuthPubKeyIndex }
::= { sshClientAuthPubKeyTable 1 }
SSHClientAuthPubKeyEntry ::=
SEQUENCE {
sshClientAuthRemoteAccessIdIndex INTEGER,
sshClientAuthPubKeyIndex INTEGER,
sshClientAuthPubKeyType INTEGER,
sshClientAuthPubKeySize INTEGER,
sshClientAuthPubKeyFingerprint OCTET STRING,
sshClientAuthPubKeyAcceptFrom OCTET STRING
}
sshClientAuthRemoteAccessIdIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The primary table index is the same value as
the associated remoteAccessIdEntryIndex used
as an index into the remoteAccessIdsTable."
::= { sshClientAuthPubKeyEntry 1 }
sshClientAuthPubKeyIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The secondary table index used to select
one of the client authentication public
keys for a particular remote access Id.
The index is an integer value from 1 to N
where N is the number of keys associated
with a particular remote access Id.
An addition always causes the value of N to increase
by one, effectively adding an entry after the
existing keys for that remote access Id.
The underlying SSH server implementation searches
the keys in order from 1 to N when attempting public
key authentication.
NOTE:A maximum of 4 public keys can be installed
for one remote access Id."
::= { sshClientAuthPubKeyEntry 2 }
sshClientAuthPubKeyType OBJECT-TYPE
SYNTAX INTEGER {
sshDss (1),
sshRsa (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the SSH public key represented by
this entry."
::= { sshClientAuthPubKeyEntry 3 }
sshClientAuthPubKeySize OBJECT-TYPE
SYNTAX INTEGER {
bits512 (1),
bits768 (2),
bits1024 (3),
bits2048 (4),
bits4096 (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the SSH public key represented by
this entry."
::= { sshClientAuthPubKeyEntry 4 }
sshClientAuthPubKeyFingerprint OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The RSA fingerprint of the SSH public key represented
by this entry.
This value can be used with the SSH client to
verify, on the initial connection, that the Secure Shell
server responding to the request is the server running
on the managed entity. This is the fingerprint of the
operational host key pair. If the key pair represented
by this entry is not operational then sixteen null octets
must be returned."
::= { sshClientAuthPubKeyEntry 5 }
sshClientAuthPubKeyAcceptFrom OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a filter that describes the set of SSH client
IP addresses and host names that can establish
SSH connections to the AMM authenticated by the public key
represented by this entry of the table. The filter is a
comma-separated list of IP addresses and/or hostnames.
A question mark may be used to match any single character.
An asterisk may be used to match multiple characters.
An exclamation point may preceed an IP address or hostname
to deny acccess from that IP address or hostname.
The format of the Accept From specification is:
from=PATTERN-LIST
PATTERN-LIST is the filter, which must be enclosed in
double quotation marks."
::= { sshClientAuthPubKeyEntry 6 }
sshClientAuthPubKeyUnused OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of available storage locations that may be
used to install additional Client Authentication
Public Keys. This number decreases by one when a new
key is added to the configuration."
::= { sshClientAuth 2 }
-- ***********************************************************************
-- SP Clock
-- ***********************************************************************
spClock OBJECT IDENTIFIER ::= { configureSP 2 }
spClockDateAndTimeSetting OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display XCC clock date and time setting, The format of the value is month/day/year, hour:minutes:seconds."
::= { spClock 1 }
spClockTimezoneSetting OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display XCC clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST)
settings.
The following table lists GMT offsets and associated DST
information. DST is not observed in time zones where
the 'Observe DST' value does not contain 'yes' in the table.
Also, note that in some cases additional information
is required to determine the clock adjustment when DST is
observed.
Examples
-If the GMT offset is +3:30, the value is:'+3:30,no'
-For Eastern Standard Time and observing DST, the value is:'-5:00,yes'
-For Turkey and observing DST, the value is:'+2:00,yes,3'
GMT Observe Additional
Offset DST? DST value
______ _______ __________
GMT+0 yes | no
GMT+1 yes | no
GMT+2 yes | no When 'Observe DST?' value is 'yes':
'1' Europe/Eastern Europe (ee)
'3' Turkey (tky)
'4' Asia/Beirut (bei)
'5' Asia/Amman (amm)
'6' Asia/Jerusalem (jem)
GMT+3 yes | no
GMT+3:30 yes | no
GMT+4 no
GMT+4:30 no
GMT+5 no
GMT+5:30 no
GMT+5:45 no
GMT+6 no
GMT+6:30 no
GMT+7 no
GMT+8 no
GMT+9 no
GMT+9:30 yes | no
GMT+10 yes | no
GMT+11 no
GMT+12 yes | no
GMT+13 no
GMT-12 no
GMT-11 yes | no
GMT-10 no
GMT-9 yes | no
GMT-8 yes | no
GMT-7 yes | no When 'Observe DST?' value is 'yes':
'7' US/Mountain (mtn)
'8' America/Mazatlan (maz)
GMT-6 yes | no When 'Observe DST?' value is 'yes':
'9' America/Mexico City (mex)
'10' Canada/Central (cna)
GMT-5 yes | no When 'Observe DST?' value is 'yes':
'11' Cuba (cub)
GMT-4:30 no
GMT-4 yes | no When 'Observe DST?' value is 'yes':
'13' America/Asuncion (asu)
'14' America/Cuiaba (cui)
'15' America/Santiago (san)
'16' Canada/Atlantic (cat)
GMT-3:30 yes | no
GMT-3 yes | no When 'Observe DST?' value is 'yes':
'17' America/Gothab (gtb)
'19' Brazil/East (bre)
GMT-2 no
GMT-1 yes | no "
::= { spClock 2 }
-- ***********************************************************************
-- SP identification
-- ***********************************************************************
spIdentification OBJECT IDENTIFIER ::= { configureSP 3 }
spTxtId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"XCC text ID."
::= { spIdentification 1 }
spRoomID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Room where the system is located."
::= { spIdentification 2 }
spRackID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ID for Rack that contains this system."
::= { spIdentification 3 }
spRackUnitPosition OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Position within the rack for this system."
::= { spIdentification 4 }
spRackUnitHeight OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rack units occupied by this system."
::= { spIdentification 5 }
spRackBladeBay OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bay number for system contained in a blade chassis."
::= { spIdentification 6 }
spFullPostalAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A NULL terminated 300 byte string that contains the
full postal address for this system."
::= { spIdentification 7 }
-- ***********************************************************************
-- Network Configuration
-- ***********************************************************************
networkConfiguration OBJECT IDENTIFIER ::= { configureSP 4 }
-- ***********************************************************************
-- Network Interfaces
-- ***********************************************************************
networkInterfaces OBJECT IDENTIFIER ::= { networkConfiguration 1 }
-- ***********************************************************************
-- Ethernet Interface 1
-- ***********************************************************************
ethernetInterface OBJECT IDENTIFIER ::= { networkInterfaces 1 }
ethernetInterfaceType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of interface. Indicates 'Ethernet-1'."
::= { ethernetInterface 1 }
ethernetInterfaceEnabled OBJECT-TYPE
SYNTAX INTEGER {
interfaceDisabled(0),
interfaceEnabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Disable or enable the interface."
::= { ethernetInterface 2 }
ethernetInterfaceHostName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the 64 byte null terminated DNS host name for this
interface."
::= { ethernetInterface 3 }
ethernetInterfaceIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IP address for the ethernet interface."
::= { ethernetInterface 4 }
ethernetInterfaceAutoNegotiate OBJECT-TYPE
SYNTAX INTEGER {
enabled(0),
disabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is enabled, then we should ignore Speed/Duplex."
::= { ethernetInterface 5 }
ethernetInterfaceDataRate OBJECT-TYPE
SYNTAX INTEGER {
enet10Megabit(3),
enet100Megabit(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the data transfer rate to be used over the ethernet
interface 10Mb/100Mb/Auto. Note that the value of this variable
is ignored if ethernetInterfaceAutoNegotiate is set to enabled(0)."
::= { ethernetInterface 6 }
ethernetInterfaceDuplexSetting OBJECT-TYPE
SYNTAX INTEGER {
fullDuplex(1),
halfDuplex(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the duplex settings for the data transfer rate to be used over
the ethernet interface Half/Full/Auto."
::= { ethernetInterface 7 }
ethernetInterfaceLAA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(17))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the locally administered MAC address. The locally administered
address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This
value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and
A - F. This XCC subsystem does not allow use of a multicast address. A multicast
address has the least significant bit of the first byte set to a 1. The first
byte must, therefore, be an even number."
::= { ethernetInterface 8 }
ethernetInterfaceDhcpEnabled OBJECT-TYPE
SYNTAX INTEGER {
dhcpDisabled(0),
dhcpEnabled(1),
dhcpTry(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Disable or enable DHCP on this interface."
::= { ethernetInterface 9 }
ethernetInterfaceGatewayIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IP address of the gateway/router for the ethernet
interface."
::= { ethernetInterface 10 }
ethernetInterfaceBIA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies the burned-in MAC (BIA) address."
::= { ethernetInterface 11 }
ethernetInterfaceMTU OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Maximum Transmission Unit(MTU) for the ethernet
interface"
::= { ethernetInterface 12 }
ethernetInterfaceSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Subnet Mask for the ethernet
interface"
::= { ethernetInterface 13 }
-- ***********************************************************************
-- DHCP Server Assigned Settings for ethernet interface 1
-- ***********************************************************************
dhcpEthernetInterface OBJECT IDENTIFIER ::= { ethernetInterface 14 }
dhcpHostName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the 64 byte null terminated DNS host name for this
interface, assigned by the DHCP server."
::= { dhcpEthernetInterface 1 }
dhcpIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IP address for the ehternet interface,
assigned by the DHCP server."
::= { dhcpEthernetInterface 2 }
dhcpGatewayIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IP address of the gateway/router for the ethernet
interface, assigned by the DHCP server."
::= { dhcpEthernetInterface 3 }
dhcpSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Subnet Mask for the ethernet
interface, assigned by the DHCP server."
::= { dhcpEthernetInterface 4 }
dhcpDomainName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the 64 byte null terminated Domain Name for this
interface, assigned by the DHCP server."
::= { dhcpEthernetInterface 5 }
dhcpPrimaryDNSServer OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Primary DNS server, assigned by the DHCP server."
::= { dhcpEthernetInterface 6 }
dhcpSecondaryDNSServer OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Secondary DNS server, assigned by the DHCP server."
::= { dhcpEthernetInterface 7 }
dhcpTertiaryDNSServer OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the tertiary DNS server, assigned by the DHCP server."
::= { dhcpEthernetInterface 8 }
-- ********************************************************************************
-- VLAN configuration
-- ********************************************************************************
ethernetInterfaceVlan OBJECT-TYPE
SYNTAX INTEGER {
enabled(0),
disabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If this is enabled, assign VLAN ID needs to be assigned.
NOTE: This is not supported on blades."
::= { ethernetInterface 15 }
ethernetInterfaceVlanID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the VLAN ID for the ethernet interface.
NOTE: This is not supported in blades."
::= { ethernetInterface 16 }
-- ********************************************************************************
-- Ethernet Interface IPv6
-- ********************************************************************************
ethernetInterfaceIPv6 OBJECT IDENTIFIER ::= { networkInterfaces 4 }
ethernetInterfaceIPv6Enabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current IPv6 enabled or disabled state of this XCC.
NOTE: If IPv6 address(es) have been configured for one or more
interfaces/protocols/services on this XCC, when you update
the firmware to a level which does not support IPv6, all IPv6
connectivity will be lost, and services/interfaces for which an IPv6
address was configured may not function properly. You will be required
to reconfigure these services/interfaces."
::= { ethernetInterfaceIPv6 2 }
ethernetInterfaceIPv6Config OBJECT IDENTIFIER ::= { ethernetInterfaceIPv6 5 }
ethernetInterfaceIPv6LocalAddress OBJECT IDENTIFIER ::= { ethernetInterfaceIPv6Config 1 }
ethernetInterfaceIPv6LinkLocalAddress OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPv6 link local IP address for the ethernet interface.
NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this
object has the value '0:0:0:0:0:0:0:0'."
::= { ethernetInterfaceIPv6LocalAddress 1 }
ethernetInterfaceIPv6StaticIPConfig OBJECT IDENTIFIER ::= { ethernetInterfaceIPv6Config 2 }
ethernetInterfaceIPv6StaticIPConfigEnabled OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPv6 static IP address enabled or disabled state for the ethernet interface."
::= { ethernetInterfaceIPv6StaticIPConfig 1 }
ethernetInterfaceIPv6StaticIPAddress OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPv6 static IP address for the ethernet interface.
NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this
object has the value '0:0:0:0:0:0:0:0'."
::= { ethernetInterfaceIPv6StaticIPConfig 2 }
ethernetInterfaceIPv6StaticIPAddressPrefixLen OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPv6 static IP address prefix length for the ethernet interface.
NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this
object has the value 0."
::= { ethernetInterfaceIPv6StaticIPConfig 3 }
ethernetInterfaceIPv6StaticIPDefaultRoute OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPv6 static IP address default route for the ethernet interface.
NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this
object has the value '0:0:0:0:0:0:0:0'."
::= { ethernetInterfaceIPv6StaticIPConfig 4 }
ethernetInterfaceIPv6AutoIPConfig OBJECT IDENTIFIER ::= { ethernetInterfaceIPv6Config 3 }
ethernetInterfaceDHCPv6Config OBJECT IDENTIFIER ::= { ethernetInterfaceIPv6AutoIPConfig 2 }
ethernetInterfaceDHCPv6Enabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The DHCPv6 enabled or disabled state for the ethernet interface."
::= { ethernetInterfaceDHCPv6Config 1 }
ethernetInterfaceDHCPv6IPAddress OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPv6 address for the ethernet interface, assigned by DHCPv6 server.
NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled
is disabled or if DHCPv6 server is not available, this object has the value
'0:0:0:0:0:0:0:0'."
::= { ethernetInterfaceDHCPv6Config 2 }
ethernetInterfaceDHCPv6DomainName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The 64 byte Domain Name for the ethernet interface,
assigned by the DHCPv6 server.
NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled
is disabled or if DHCPv6 server is not available, this object has the
value '(Not available)'."
::= { ethernetInterfaceDHCPv6Config 4 }
ethernetInterfaceDHCPv6PrimaryDNSServer OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The primary DNS server, assigned by the DHCPv6 server.
NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled
is disabled or if DHCPv6 server is not available, this object has the
value '0:0:0:0:0:0:0:0'."
::= { ethernetInterfaceDHCPv6Config 5 }
ethernetInterfaceDHCPv6SecondaryDNSServer OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The secondary DNS server, assigned by the DHCPv6 server.
NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled
is disabled or if DHCPv6 server is not available, this object has the
value '0:0:0:0:0:0:0:0'."
::= { ethernetInterfaceDHCPv6Config 6 }
ethernetInterfaceDHCPv6TertiaryDNSServer OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The tertiary DNS server, assigned by the DHCPv6 server.
NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled
is disabled or if DHCPv6 server is not available, this object has the
value '0:0:0:0:0:0:0:0'."
::= { ethernetInterfaceDHCPv6Config 7 }
ethernetInterfaceDHCPv6Server OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The DHCPv6 server IPv6 address used to acquire the DHCP settings.
NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled
is disabled or if DHCPv6 server is not available, this object has the
value '0:0:0:0:0:0:0:0'."
::= { ethernetInterfaceDHCPv6Config 8 }
ethernetInterfaceIPv6StatelessAutoConfig OBJECT IDENTIFIER ::= { ethernetInterfaceIPv6AutoIPConfig 3 }
ethernetInterfaceIPv6StatelessAutoConfigEnabled OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface."
::= { ethernetInterfaceIPv6StatelessAutoConfig 1 }
ethernetInterfaceStatelessAutoConfigAddressesTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthernetInterfaceStatelessAutoConfigAddressesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of stateless Auto-Config addresses entries"
::= { ethernetInterfaceIPv6StatelessAutoConfig 2 }
ethernetInterfaceStatelessAutoConfigAddressesEntry OBJECT-TYPE
SYNTAX EthernetInterfaceStatelessAutoConfigAddressesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Stateless Auto-Config address entries"
INDEX { ethernetInterfaceStatelessAutoConfigAddressesIndex }
::= { ethernetInterfaceStatelessAutoConfigAddressesTable 1 }
EthernetInterfaceStatelessAutoConfigAddressesEntry ::= SEQUENCE {
ethernetInterfaceStatelessAutoConfigAddressesIndex INTEGER,
ethernetInterfaceStatelessAutoConfigAddresses InetAddressIPv6,
ethernetInterfaceStatelessAutoConfigAddressesPrefixLen INTEGER
}
ethernetInterfaceStatelessAutoConfigAddressesIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for stateless Auto-Config addresses.
NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or
ethernetInterfaceIPv6Enabled is currently disabled, this
object will show nothing."
::= { ethernetInterfaceStatelessAutoConfigAddressesEntry 1 }
ethernetInterfaceStatelessAutoConfigAddresses OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The stateless Auto-Configuration IPv6 address.
NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or
ethernetInterfaceIPv6Enabled is currently disabled, this
object will show nothing."
::= { ethernetInterfaceStatelessAutoConfigAddressesEntry 2 }
ethernetInterfaceStatelessAutoConfigAddressesPrefixLen OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The stateless Auto-Configration address prefix length.
NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or
ethernetInterfaceIPv6Enabled is currently disabled, this
object will show nothing."
::= { ethernetInterfaceStatelessAutoConfigAddressesEntry 3 }
-- ********************************************************************************
-- VLANs for System Management
-- ********************************************************************************
vlansSM OBJECT IDENTIFIER ::= { networkInterfaces 5 }
vlansSMvlan1config OBJECT IDENTIFIER ::= { vlansSM 1 }
vlansSMvlan1Name OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of VLAN1, 1-64 characters."
::= {vlansSMvlan1config 1}
vlansSMvlan1vlanId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN ID for VLAN1."
::= {vlansSMvlan1config 2}
vlansSMvlan1State OBJECT-TYPE
SYNTAX INTEGER { disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of VLAN1"
::= {vlansSMvlan1config 3}
vlansSMvlan1RemoteControl OBJECT-TYPE
SYNTAX INTEGER { disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the Remote Control feature for VLAN1.
Note that Remote Control can only be enabled on one VLAN."
::= {vlansSMvlan1config 4}
vlansSMvlan1SSerialOverLan OBJECT-TYPE
SYNTAX INTEGER { disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the Serail Over LAN feature for VLAN1.
Note that Serial Over LAN can only be enabled on one VLAN."
::= {vlansSMvlan1config 5}
vlansSMvlan2config OBJECT IDENTIFIER ::= { vlansSM 2 }
vlansSMvlan2Name OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of VLAN1, 1-64 characters."
::= {vlansSMvlan2config 1}
vlansSMvlan2vlanId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN ID for VLAN2."
::= {vlansSMvlan2config 2}
vlansSMvlan2State OBJECT-TYPE
SYNTAX INTEGER { disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of VLAN2"
::= {vlansSMvlan2config 3}
vlansSMvlan2RemoteControl OBJECT-TYPE
SYNTAX INTEGER { disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the Remote Control feature for VLAN2.
Note that Remote Control can only be enabled on one VLAN."
::= {vlansSMvlan2config 4}
vlansSMvlan2SerialOverLan OBJECT-TYPE
SYNTAX INTEGER { disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the Serail Over LAN feature for VLAN2.
Note that Serial Over LAN can only be enabled on one VLAN."
::= {vlansSMvlan2config 5}
vlansSMvlan2ipv4Config OBJECT IDENTIFIER ::= { vlansSMvlan2config 6 }
vlansSMvlan2IPv4Address OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IPv4 address for the VLAN2 interface."
::= { vlansSMvlan2ipv4Config 1 }
vlansSMvlan2IPv4Gateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Gateway IPv4 address for the VLAN2 interface."
::= { vlansSMvlan2ipv4Config 2 }
vlansSMvlan2IPv4SubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Subnet Mask for the IPv4 address for the VLAN2 interface."
::= { vlansSMvlan2ipv4Config 3 }
vlansSMvlan2ipv6Config OBJECT IDENTIFIER ::= { vlansSMvlan2config 7 }
vlansSMvlan2IPv6Address OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IPv6 address for the VLAN2 interface."
::= { vlansSMvlan2ipv6Config 1 }
vlansSMvlan2IPv6Gateway OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Gateway IPv6 address for the VLAN2 interface."
::= { vlansSMvlan2ipv6Config 2 }
vlansSMvlan2IPv6PrefixLength OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Prefix Length for the IPv6 address for the VLAN2 interface."
::= { vlansSMvlan2ipv6Config 3 }
vlansSMvlan2ipv4StatusRoutes OBJECT IDENTIFIER ::= { vlansSMvlan2config 8 }
vlansSMvlan2IPv4StaticRouteIP1 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IPv4 address for the first IPv4 static route."
::= { vlansSMvlan2ipv4StatusRoutes 1 }
vlansSMvlan2IPv4StaticRouteSM1 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Subnet Mask for the first IPv4 static route."
::= { vlansSMvlan2ipv4StatusRoutes 2 }
vlansSMvlan2IPv4StaticRouteIP2 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IPv4 address for the second IPv4 static route."
::= { vlansSMvlan2ipv4StatusRoutes 3 }
vlansSMvlan2IPv4StaticRouteSM2 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Subnet Mask for the second IPv4 static route."
::= { vlansSMvlan2ipv4StatusRoutes 4 }
vlansSMvlan2IPv4StaticRouteIP3 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IPv4 address for the third IPv4 static route."
::= { vlansSMvlan2ipv4StatusRoutes 5 }
vlansSMvlan2IPv4StaticRouteSM3 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Subnet Mask for the third IPv4 static route."
::= { vlansSMvlan2ipv4StatusRoutes 6 }
vlansSMvlan2ipv6StatusRoutes OBJECT IDENTIFIER ::= { vlansSMvlan2config 9 }
vlansSMvlan2IPv6StaticRouteIP1 OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IPv6 address for the first IPv6 static route."
::= { vlansSMvlan2ipv6StatusRoutes 1 }
vlansSMvlan2IPv6StaticRoutePL1 OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Prefix Length for the first IPv6 static route."
::= { vlansSMvlan2ipv6StatusRoutes 2 }
vlansSMvlan2IPv6StaticRouteIP2 OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IPv6 address for the second IPv6 static route."
::= { vlansSMvlan2ipv6StatusRoutes 3 }
vlansSMvlan2IPv6StaticRoutePL2 OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Prefix Length for the second IPv6 static route."
::= { vlansSMvlan2ipv6StatusRoutes 4 }
vlansSMvlan2IPv6StaticRouteIP3 OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IPv6 address for the third IPv6 static route."
::= { vlansSMvlan2ipv6StatusRoutes 5 }
vlansSMvlan2IPv6StaticRoutePL3 OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Prefix Length for the third IPv6 static route."
::= { vlansSMvlan2ipv6StatusRoutes 6 }
vlansSMvlanControl OBJECT IDENTIFIER ::= { vlansSM 3 }
vlansSMvlanConfigRevertTimout OBJECT-TYPE
SYNTAX INTEGER (1..60)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the VLAN Config Revert Timeout value."
::= { vlansSMvlanControl 1 }
ddnsStatus OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Dynamic DNS provides the capability for a networked device
to notify a domain name server to change, in real time, the
active DNS configuration of its configured hostnames, addresses
or other information stored in DNS. With Dynamic DNS, host
computers gain the capability to notify their respective DNS
server of the IP address they have received from a DHCP server
or through self-configuration."
::= { networkInterfaces 10 }
hostName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the DNS host name for this system. This object
provides the exact same function as ethernetInterfaceHostName"
::= { networkInterfaces 11 }
ddnsDomainToUse OBJECT-TYPE
SYNTAX INTEGER {
dhcp(1),
manual(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The domain name to be used with Dynamic DNS. "
::= { networkInterfaces 12 }
domainName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The user assigned DNS domain name."
::= { networkInterfaces 13 }
-- ***********************************************************************
-- LAN over USB Settings for ethernet interface
-- ***********************************************************************
lanOverUSBInterface OBJECT IDENTIFIER ::= { networkInterfaces 14 }
xccUSBIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IP address for the LAN over USB of XCC."
::= { lanOverUSBInterface 1 }
xccUSBSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Subnet Mask for the LAN over USB of XCC."
::= { lanOverUSBInterface 2 }
osUSBIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the IP address for the LAN over USB of OS."
::= { lanOverUSBInterface 3 }
-- ***********************************************************************
-- TCP/IP Protocol Configuration
-- ***********************************************************************
tcpProtocols OBJECT IDENTIFIER ::= { networkConfiguration 2 }
-- ***********************************************************************
-- SNMP Agent Configuration
-- ***********************************************************************
snmpAgentConfig OBJECT IDENTIFIER ::= { tcpProtocols 1 }
snmpSystemName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..48))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A NULL terminated 48 byte string that contains the
SNMP agent name."
::= { snmpAgentConfig 1 }
snmpSystemContact OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..48))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A NULL terminated 48 byte string that contains the
SNMP agent contact name."
::= { snmpAgentConfig 2 }
snmpSystemLocation OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..48))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A NULL terminated 48 byte string that contains the
SNMP agent location name."
::= { snmpAgentConfig 3 }
snmpSystemAgentTrapsDisable OBJECT-TYPE
SYNTAX INTEGER {
trapsDisabled(0),
trapsV1Enabled(1),
trapsV3Enabled(2),
trapsV1V3Enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Disable or enable SNMP V1 and V3 traps."
::= { snmpAgentConfig 4 }
-- ***********************************************************************
-- SNMP Agent Community Configuration
-- ***********************************************************************
snmpAgentCommunityConfig OBJECT IDENTIFIER ::= { snmpAgentConfig 5 }
snmpCommunityEntryCommunityName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SNMP Community entry name."
::= { snmpAgentCommunityConfig 1 }
snmpCommunityEntryCommunityIpAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SNMP Community IP address or host name."
::= { snmpAgentCommunityConfig 2 }
-- ***********************************************************************
-- SNMP v3 Agent Configuration
-- ***********************************************************************
snmpv3SystemAgentEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Disable or enable the SNMPv3 agent."
::= { snmpAgentConfig 7 }
-- ********************************************************************************
-- SNMP Agent User Profile Configuration
-- ********************************************************************************
snmpAgentUserProfileConfig OBJECT IDENTIFIER ::= { snmpAgentConfig 8 }
-- ********************************************************************************
-- SNMP User Profile Configuration table
-- ********************************************************************************
snmpUserProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnmpUserProfileEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of SNMPv3 User Profile entries"
::= { snmpAgentUserProfileConfig 1 }
snmpUserProfileEntry OBJECT-TYPE
SYNTAX SnmpUserProfileEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SNMP User Profile entries"
INDEX { snmpUserProfileEntryIndex }
::= { snmpUserProfileTable 1 }
SnmpUserProfileEntry ::= SEQUENCE {
snmpUserProfileEntryIndex INTEGER,
snmpUserProfileEntryAuthProt INTEGER,
snmpUserProfileEntryPrivProt INTEGER,
snmpUserProfileEntryViewType INTEGER,
snmpUserProfileEntryIpAddress OCTET STRING
}
snmpUserProfileEntryIndex OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for SNMPv3 Agent User Profile entry."
::= { snmpUserProfileEntry 1 }
snmpUserProfileEntryAuthProt OBJECT-TYPE
SYNTAX INTEGER {
none (1),
sha (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SNMPv3 User Profile entry - Authentication Protocol supported by the user."
::= { snmpUserProfileEntry 2 }
snmpUserProfileEntryPrivProt OBJECT-TYPE
SYNTAX INTEGER {
none (1),
des (2),
aes (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SNMPv3 User Profile entry - Privacy Protocol supported by the user."
::= { snmpUserProfileEntry 3 }
snmpUserProfileEntryViewType OBJECT-TYPE
SYNTAX INTEGER {
get(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SNMPv3 User Profile entry - Access level (Get) of the user. "
::= { snmpUserProfileEntry 5 }
snmpUserProfileEntryIpAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SNMPv3 User Profile entry - IP address or host name."
::= { snmpUserProfileEntry 6 }
-- ***********************************************************************
-- DNS Configuration
-- ***********************************************************************
dnsConfig OBJECT IDENTIFIER ::= { tcpProtocols 2 }
dnsEnabled OBJECT-TYPE
SYNTAX INTEGER {
dnsDisabled(0),
dnsEnabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Disable or enable the DNS agent."
::= { dnsConfig 1 }
dnsServerIPAddress1 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the primary DNS server IP address."
::= { dnsConfig 2 }
dnsServerIPAddress2 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the secondary DNS server IP address."
::= { dnsConfig 3 }
dnsServerIPAddress3 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the tertiary DNS server IP address."
::= { dnsConfig 4 }
dnsServerIPv6Address1 OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the primary IPv6 DNS server address."
::= { dnsConfig 12 }
dnsServerIPv6Address2 OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the secondary IPv6 DNS server address."
::= { dnsConfig 13 }
dnsServerIPv6Address3 OBJECT-TYPE
SYNTAX InetAddressIPv6
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the tertiary IPv6 DNS server address."
::= { dnsConfig 14 }
dnsPriority OBJECT-TYPE
SYNTAX INTEGER {
ipv6(1),
ipv4(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Tells the order host names are resolved. The options are
to either first resolve with an IPv6 DNS server or to first
resolve with an IPv6 DNS server."
::= { dnsConfig 20 }
dnsLXCADiscovery OBJECT-TYPE
SYNTAX INTEGER {
dnsLXCADiscoveryDisabled(0),
dnsLXCADiscoveryEnabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Disable or enable LXCA discovery using DNS SRV records."
::= { dnsConfig 21 }
-- ***********************************************************************
-- SMTP Configuration
-- ***********************************************************************
smtpConfig OBJECT IDENTIFIER ::= { tcpProtocols 3 }
smtpServerNameOrIPAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A NULL terminated 64 byte string that contains the
SMTP server Host name or IP address(a.b.c.d)."
::= { smtpConfig 1 }
smtpServerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SMTP server port number."
::= { smtpConfig 2 }
smtpServerAuthentication OBJECT-TYPE
SYNTAX INTEGER {
enabled(0),
disabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Enable/disable SMTP-AUTH function."
::= { smtpConfig 3 }
smtpServerAuthenticationUser OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SMTP authentication user name"
::= { smtpConfig 4 }
smtpServerAuthenticationMethod OBJECT-TYPE
SYNTAX INTEGER {
plain(0),
cram-md5(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SMTP authentication method , support CRAM-MD5 and PLAIN only"
::= { smtpConfig 6 }
smtpServerReversePath OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A NULL terminated 256 byte string that contains the SMTP Reverse Path.
The user can substitute their own sender information in place of the
XCC default sender information. For example xcc@mycompany.com in place
of the default alertmgr@a.b.c.d."
::= { smtpConfig 7 }
-- ***********************************************************************
-- Tcp Application Configuration
-- ***********************************************************************
tcpApplicationConfig OBJECT IDENTIFIER ::= { tcpProtocols 4 }
slpAddrType OBJECT-TYPE
SYNTAX INTEGER {
multicast(0),
broadcast(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get SLP address type. Note that when slpAddrType is broadast then the multicast address in slpMulticastAddt will be ignored."
::= { tcpApplicationConfig 2 }
slpMulticastAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Service Locator Protocol Multicast address"
::= { tcpApplicationConfig 3 }
-- ***********************************************************************
-- The SSH Server Configuration Group
-- ***********************************************************************
sshServerConfig OBJECT IDENTIFIER ::= { tcpApplicationConfig 5 }
sshServerHostKeySize OBJECT-TYPE
SYNTAX INTEGER {
bits512 (1),
bits768 (2),
bits1024 (3),
bits2048 (4),
bits4096 (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the public/private host key pair.
NOTE: The XCC supports only the bits1048 value."
::= { sshServerConfig 1 }
sshServerHostKeyFingerprint OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The RSA fingerprint of the public part of the host key
pair. This value can be used with the SSH client to
verify, on the initial connection, that the Secure Shell
server responding to the request is the server running
on the XCC. Null Empty string if no RSA key exists."
::= { sshServerConfig 2 }
sshEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Disable/Enable SSH."
::= { sshServerConfig 5 }
-- ***********************************************************************
-- The SSL Configuration Group
-- ***********************************************************************
sslConfig OBJECT IDENTIFIER ::= { tcpApplicationConfig 6 }
sslEnableHTTPSforWeb OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status for web HTTPS service.
To use SSL, a client web browser must be configured to use SSL3 and/or TLS. Older export-grade browsers with only SSL2 support cannot be used."
::= { sslConfig 1 }
sslEnableHTTPSforCIMXML OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status for CIM over HTTPS service."
::= { sslConfig 2 }
sslEnableSecureClientLDAP OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status of the Secure LDAP Client."
::= { sslConfig 3 }
sslServerCertificate OBJECT IDENTIFIER ::= { sslConfig 4 }
sslServerCertificateStatus OBJECT-TYPE
SYNTAX INTEGER {
no-cert-installed(1),
self-signed-installed(2),
ca-signed-installed(3),
csr-generated(4),
self-signed-and-csr-generated(5),
ca-signed-and-csr-generated(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status of the installed HTTPS certificate.
1 = Private Key and Cert/CSR not available.
2 = Private Key and Self-signed cert installed.
3 = Private Key and CA-signed cert installed.
4 = Private Key stored, CSR available for download.
5 = Private Key and Self-signed cert installed, Private Key stored, CSR available for download.
6 = Private Key and CA-signed cert installed, Private Key stored, CSR available for download. "
::= { sslServerCertificate 1 }
sslServerCertificateExpirationDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Expiration date of the installed HTTPS certificate."
::= { sslServerCertificate 2 }
sslLDAPTrustedCertificate OBJECT IDENTIFIER ::= { sslConfig 5 }
sslLDAPTrustedCertificate1Status OBJECT-TYPE
SYNTAX INTEGER {
not-installed(0),
installed(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status of the LDAP trusted certificate #1.
0 = certificate not installed
1 = certificate installed. "
::= { sslLDAPTrustedCertificate 1 }
sslLDAPTrustedCertificate1ExpirationDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Expiration date of the LDAP trusted certificate #1 if it is installed."
::= { sslLDAPTrustedCertificate 2 }
sslLDAPTrustedCertificate2Status OBJECT-TYPE
SYNTAX INTEGER {
not-installed(0),
installed(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status of the LDAP trusted certificate #2.
0 = certificate not installed
1 = certificate installed. "
::= { sslLDAPTrustedCertificate 3 }
sslLDAPTrustedCertificate2ExpirationDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Expiration date of the LDAP trusted certificate #2 if it is installed.."
::= { sslLDAPTrustedCertificate 4 }
sslLDAPTrustedCertificate3Status OBJECT-TYPE
SYNTAX INTEGER {
not-installed(0),
installed(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status of the LDAP trusted certificate #3.
0 = certificate not installed
1 = certificate installed. "
::= { sslLDAPTrustedCertificate 5 }
sslLDAPTrustedCertificate3ExpirationDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Expiration date of the LDAP trusted certificate #3 if it is installed."
::= { sslLDAPTrustedCertificate 6 }
sslLDAPTrustedCertificate4Status OBJECT-TYPE
SYNTAX INTEGER {
not-installed(0),
installed(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status of the LDAP trusted certificate #4.
0 = certificate not installed
1 = certificate installed. "
::= { sslLDAPTrustedCertificate 7 }
sslLDAPTrustedCertificate4ExpirationDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Expiration date of the LDAP trusted certificate #4 if it is installed."
::= { sslLDAPTrustedCertificate 8 }
-- ***********************************************************************
-- Certificate Domain Names
-- ***********************************************************************
certDomainNames OBJECT IDENTIFIER ::= { tcpApplicationConfig 8 }
certDomainNameTable OBJECT-TYPE
SYNTAX SEQUENCE OF CertDomainNameEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This table contains certificate domain names and status."
::= { certDomainNames 1 }
certDomainNameEntry OBJECT-TYPE
SYNTAX CertDomainNameEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Each row contains a certificate domain name and status."
INDEX { certDomainNameIndex }
::= { certDomainNameTable 1 }
CertDomainNameEntry ::=
SEQUENCE {
certDomainNameIndex INTEGER,
certDomainName OCTET STRING,
certDomainNameStatus OCTET STRING
}
certDomainNameIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The index number of one certificate domain name entry."
::= { certDomainNameEntry 1 }
certDomainName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Certificate Domain Name of one certificate domain name entry."
::= { certDomainNameEntry 2 }
certDomainNameStatus OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the Certificate Domain Name entry."
::= { certDomainNameEntry 3 }
-- ***********************************************************************
-- Storage Key Repository Servers
-- ***********************************************************************
skrServers OBJECT IDENTIFIER ::= { tcpApplicationConfig 9 }
skrServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SkrServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This table contains Storage Key Repository Server hostnames and ports."
::= { skrServers 1 }
skrServerEntry OBJECT-TYPE
SYNTAX SkrServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Each row contains a Storage Key Repository Server hostname and port."
INDEX { skrServerIndex }
::= { skrServerTable 1 }
SkrServerEntry ::=
SEQUENCE {
skrServerIndex INTEGER,
skrServerHostname OCTET STRING,
skrServerPort INTEGER
}
skrServerIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The index number of one Storage Key Repository Server entry."
::= { skrServerEntry 1 }
skrServerHostname OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Storage Key Repository Server hostname or IP address."
::= { skrServerEntry 2 }
skrServerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Storage Key Repository Server port number."
::= { skrServerEntry 3 }
skrDeviceGroup OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..17))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An optional NULL terminated 16 character string that contains the Device Group that the server drives belong to."
::= { skrServers 3 }
skrClientConfigCertficate OBJECT IDENTIFIER ::= { skrServers 4 }
skrClientCertificateStatus OBJECT-TYPE
SYNTAX INTEGER {
no-cert-installed(1),
self-signed-installed(2),
ca-signed-installed(3),
csr-generated(4),
self-signed-and-csr-generated(5),
ca-signed-and-csr-generated(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status of the installed Web certificates.
1 = Private Key and Cert/CSR not available.
2 = Private Key and Self-signed cert installed.
3 = Private Key and CA-signed cert installed.
4 = Private Key stored, CSR available for download.
5 = Private Key and Self-signed cert installed, Private Key stored, CSR available for download.
6 = Private Key and CA-signed cert installed, Private Key stored, CSR available for download. "
::= { skrClientConfigCertficate 3 }
skrClientCertificateExpirationDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Expiration date of the SKR client certificate."
::= { skrClientConfigCertficate 4 }
skrServerCertificateExpirationDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Expiration date of the SKR Server certificate."
::= { skrServers 12 }
-- ***********************************************************************
-- TCP Port Assignment
-- ***********************************************************************
tcpPortAssignmentCfg OBJECT IDENTIFIER ::= { tcpProtocols 5 }
httpPortAssignment OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HTTP port number. Default value is 80. Once changed, the url's have to
include :port at the end. "
::= { tcpPortAssignmentCfg 2 }
httpsPortAssignment OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SSL port number. Default value is 443. Once changed, the url's have to
include :port at the end."
::= { tcpPortAssignmentCfg 3 }
sshLegacyCLIPortAssignment OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SSH port number. Default value is 22."
::= { tcpPortAssignmentCfg 6 }
snmpAgentPortAssignment OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SNMP Agent port number. Default value is 161."
::= { tcpPortAssignmentCfg 8 }
snmpTrapsPortAssignment OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SNMP Traps port number. Default value is 162."
::= { tcpPortAssignmentCfg 9 }
remvidPortAssignment OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Console port number. Default value is 3900."
::= { tcpPortAssignmentCfg 10 }
cimOverHttpsPortAssignment OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CIM over Https port number."
::= { tcpPortAssignmentCfg 12 }
-- ***********************************************************************
-- LDAP Client Configuration
-- ***********************************************************************
ldapClientCfg OBJECT IDENTIFIER ::= { tcpProtocols 6 }
ldapServer1NameOrIPAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A NULL terminated 64 byte string that contains the
LDAP server host name or IP address (a.b.c.d)."
::= { ldapClientCfg 1 }
ldapServer1PortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LDAP server port number."
::= { ldapClientCfg 2 }
ldapServer2NameOrIPAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A NULL terminated 64 byte string that contains the
LDAP server host name or IP address (a.b.c.d)."
::= { ldapClientCfg 3 }
ldapServer2PortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LDAP server port number."
::= { ldapClientCfg 4 }
ldapServer3NameOrIPAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A NULL terminated 64 byte string that contains the
LDAP server host name or IP address (a.b.c.d)."
::= { ldapClientCfg 5 }
ldapServer3PortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LDAP server port number."
::= { ldapClientCfg 6 }
ldapServer4NameOrIPAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A NULL terminated 64 byte string that contains the
LDAP server host name or IP address (a.b.c.d)."
::= { ldapClientCfg 7 }
ldapServer4PortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LDAP server port number."
::= { ldapClientCfg 8 }
ldapRootDN OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..300))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Distinguished Name for root entry of directory tree.
An example might look like dn=foobar,dn=com."
::= { ldapClientCfg 9 }
ldapGroupFilter OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..511))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This filter is used for group authentication. It specifies what group or
groups that this MM belongs to. If left blank, group authentication is
disabled. Otherwise, group authentication will be performed against the
filter. The filter can be a specific group name (eg. IMMWest), a wildcard (*)
which matches everything, or a wildcard with a prefix (eg. XCC*). The default
filter is XCC*.
After user authentication, group authentication will take place, whereby an
attempt will be made to match the group or groups (that the user belongs to)
to the group filter defined here. If there is no match, the user will not pass
authentication and will be blocked. If there is a match, the login permissions
for the user will be retrieved from the matched group(s), unless the user
already has login permissions assigned directly from the user record retrieved
from the LDAP server."
::= { ldapClientCfg 11 }
ldapBindingMethod OBJECT-TYPE
SYNTAX INTEGER {
anonymousAuthentication(0),
clientAuthentication(1),
userPrincipalName(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"On initial binds to the LDAP server during user authentication, there are
three options:
Anonymous authentication: Bind attempt is made without a client DN or password.
If the bind is successful, a search will be requested in order to find an entry
on the LDAP server for the user attempting to login. If an entry is found, a
second attempt to bind will be attempted, this time with the user's DN and
password. If this succeeds, the user is deemed to have passed the user
authentication phase. Group authentication is then attempted if it is enabled.
Client authentication: Bind attempt is made with client DN and password
specified by this configuration parameter. If the bind is successful, we
proceed as above.
User Principal Name (UPN): Bind attempt is made directly with the credentials
used during the login process. If this succeeds, the user is deemed to have
passed the user authentication phase. Note that for Active Directory servers,
the userid can have the form someuser@somedomain or simply someuser."
::= { ldapClientCfg 12 }
ldapClientAuthenticationDN OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..300))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The initial bind to the LDAP server during user authentication can be
performed with anonymous authentication, client based authentication, or UPN.
The client based option requires a client DN and password as parameters to
the bind request. These parameters are configured here. Note that the password
can be left blank."
::= { ldapClientCfg 13 }
ldapRoleBasedSecurityEnabled OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value of true for RoleBasedSecurityEnabled indicates enhanced
will be used by the service processor. A value of false for
RoleBasedSecurityEnabled indicates the legacy bit mask based
security is being used."
::= { ldapClientCfg 15 }
ldapServerTargetName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When administrator chooses Enhanced Role Based Security authentication model,
he can associate one XCC with one managed target object in Snap-in (one tool
to configure LDAP users permission) via one target name. The XCC target name can
be looked as alias of XCC, administrator can change it according to his
configuration requirements. This is a string of up to 63 characters (plus the
null character)"
::= { ldapClientCfg 16 }
ldapUIDsearchAttribute OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When the binding method selected is Anonymous authentication or Client
authentication, the initial bind to the LDAP server is followed by a search
request aimed at retrieving specific information about the user, including the
user's DN, login permissions, and group ownerships. In order to retrieve this
information, the search request must specify the attribute name used to
represent userids on that server. Specifically, this name is used as a search
filter against the login id entered by the user. This attribute name is
configured here. If this field is left blank, a default of uid is used during
user authentication.
For example, on Active Directory servers, the attribute name used for userids
is often sAMAccoutName.
When the binding method selected is UPN or Strict UPN, this field defaults
automatically to userPrincipalName during user authentication if the userid
entered has the form userid@somedomain."
::= { ldapClientCfg 17 }
ldapGroupSearchAttribute OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When the MM Group Filter name is configured, it is necessary to retrieve
from the LDAP server the list of groups that a particular user belongs to.
This is required to do group authentication. In order to retrieve this list,
the search filter sent to the server must specify the attribute name associated
with groups. This field specifies this attribute name.
If this field is left blank, the attribute name in the filter will default
to memberOf."
::= { ldapClientCfg 18 }
ldapLoginPermissionAttribute OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When a user successfully authenticates via a LDAP server, it is necessary
to retrieve the login permissions for this user. In order to retrieve these
permissions, the search filter sent to the server must specify the attribute
name associated with login permissions. This field specifies this attribute
name."
::= { ldapClientCfg 19 }
ldapUseDNSOrPreConfiguredServers OBJECT-TYPE
SYNTAX INTEGER {
usePreConfiguredLDAPServers (0),
useDNSToFindLDAPServers (1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MM contains a Version 2.0 LDAP Client that may be configured to provide
user authentication through one or more LDAP servers. The LDAP server(s) to be
used for authentication can be discovered dynamically or manually pre-configured.
If the usePreConfiguredLDAPServers option is selected, up to 3 LDAP servers can
be configured. Simply enter the server's IP address or hostname (assuming DNS
is enabled). The port number for each server is optional. If left blank,
the default value of 389 is used for non-secured LDAP connections. For secured
connections, the default is 636. At least one server must be configured.
If the useDNSToFindLDAPServers is selected, the mechanisms described by RFC2782
(A DNS RR for specifying the location of services) are applied to find the
server(s). This is known as DNS SRV."
::= { ldapClientCfg 20 }
ldapDomainSource OBJECT-TYPE --XCC-only
SYNTAX INTEGER {
extractSearchDomainFromLoginID (0),
useOnlyConfiguredSearchDomainBelow (1),
tryLoginFirstThenConfiguredValue (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The DNS SRV request sent to the DNS server must specify a domain name.
The LDAP client will determine where to get this domain name based on one
of the following three options:
- extractSearchDomainFromLoginID: With this option, the LDAP client will
use the domain name in the login id. For example, if the login id is
joesmith@mycompany.com, the domain name equals mycompany.com. If the domain
name cannot be extracted, the DNS SRV will fail, causing the user
authentication to fail automatically.
- useOnlyConfiguredSearchDomainBelow: With this option, the LDAP client
will use the domain name configured in the Search Domain parameter.
- tryLoginFirstThenConfiguredValue: With this option, the LDAP client will
first attempt to extract the domain name from the login id. If this succeeds,
this domain name will be used in the DNS SRV request. If there is no domain
name present in the login id, the LDAP client will instead use the configured
Search Domain parameter as the domain name in the DNS SRV request.
If nothing is configured, user authentication will fail immediately."
::= { ldapClientCfg 21 }
ldapForestName OBJECT-TYPE -- XCC-only, return Not Found
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"In order to discover Global Catalogs (GC), the forest name must be configured
in the ForestName property. The Global Catalogs are required for users who belong
to universal groups in cross-domains. In environments where cross-domain group
membership does not apply, this field can be left blank."
::= { ldapClientCfg 22 }
ldapAuthCfg OBJECT-TYPE -- return Not Found
SYNTAX INTEGER {
authenticationAndAuthorization(0),
authenticationOnly(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize
users. If it is set to 1, LDAP server is only used to authenticate users.
Note:LDAP Authentication Only mode is currently supported only in an Active
Directory environment."
::= { ldapClientCfg 23 }
ldapSearchDomain OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter may be used as the domain name in the DNS SRV request,
depending on how the Domain Source parameter is configured."
::= { ldapClientCfg 24 }
ldapServiceName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The DNS SRV request sent to the DNS server must also specify a service name.
The configured value will be used for this purpose. If left blank, the default
value used is 'ldap'. Note that the DNS SRV request must also specify a protocol
name. This defaults to 'tcp' and is not configurable."
::= { ldapClientCfg 25 }
-- ********************************************************************************
-- NTP Configuration
-- ********************************************************************************
ntpConfig OBJECT IDENTIFIER ::= { tcpProtocols 8 }
ntpEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Disable/Enable the NTP client. The client will update
the XCC system clock at the frequency specified."
::= { ntpConfig 1 }
ntpIpAddressHostname1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"First NTP server's IP address or hostname if DNS is enabled
and configured."
::= { ntpConfig 2 }
ntpIpAddressHostname2 OBJECT-TYPE --XCC-only
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Second NTP server's IP address or hostname if DNS is enabled
and configured."
::= { ntpConfig 4 }
ntpIpAddressHostname3 OBJECT-TYPE --XCC-only
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Third NTP server's IP address or hostname if DNS is enabled
and configured."
::= { ntpConfig 6 }
ntpIpAddressHostname4 OBJECT-TYPE --XCC-only
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Fourth NTP server's IP address or hostname if DNS is enabled
and configured."
::= { ntpConfig 7 }
ntpUpdateFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The frequency in minutes that the NTP service runs.
The value range is 3 to 1440."
::= { ntpConfig 3 }
-- ********************************************************************************
-- IPMI Configuration
-- ********************************************************************************
ipmiConfig OBJECT IDENTIFIER ::= { tcpProtocols 10 }
ipmiStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status of IPMI service"
::= { ipmiConfig 1 }
-- ********************************************************************************
-- CIM Configuration
-- ********************************************************************************
cimxmlConfig OBJECT IDENTIFIER ::= { tcpProtocols 11 }
cimxmlStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status of CIM service."
::= { cimxmlConfig 1 }
-- ********************************************************************************
-- REST API Configuration
-- ********************************************************************************
restConfig OBJECT IDENTIFIER ::= { tcpProtocols 12 }
restStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the status of the REST over HTTPS."
::= { restConfig 1 }
-- ********************************************************************************
-- Check XCC Version
-- ********************************************************************************
xccVersionCheck OBJECT-TYPE
SYNTAX INTEGER {
xccVersion(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Get the XCC version type."
::= { configureSP 7 }
-- ***********************************************************************
-- System Services
-- ***********************************************************************
-- ***********************************************************************
-- System Watch Dog Timers
-- ***********************************************************************
serverTimers OBJECT IDENTIFIER ::= { generalSystemSettings 1 }
oSHang OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
twoAndHalfMinutes(150),
threeMinutes(180),
threeAndHalfMinutes(210),
fourMinutes(240),
tenMinutes(600)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number, in 1 second intervals, the XCC will
check to insure the OS is operating properly.
If the operating system fails to respond within 6 seconds to one
of these checks, the remote supervisor adapter will generate
an O/S Timeout alert(if enabled) and automatically restart the
system one time. Once the system is restarted, the O/S Watchdog
is automatically disabled until the operating
system is shutdown and the server is power cycled."
::= { serverTimers 1 }
oSLoader OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
oneHalfMinutes(1),
oneMinutes(2),
oneAndHalfMinutes(3),
twoMinutes(4),
twoAndHalfMinutes(5),
threeMinutes(6),
threeAndHalfMinutes(7),
fourMinutes(8),
fourAndHalfMinutes(9),
fiveMinutes(10),
sevenAndHalfMinutes(15),
tenMinutes(20),
fifteenMinutes(30),
twentyMinutes(40),
thirtyMinutes(60),
oneHour(120),
twoHours(240)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number in 30 second intervals the remote XCC will wait
between completion of POST and the end of loading the OS.
If this interval is exceeded, the XCC will
generate a Loader Timeout alert(if enabled) and automatically restart
the system one time. Once the system is restarted, the
Loader Timeout is automatically disabled until the operating
system is shutdown and the server is power cycled."
::= { serverTimers 2 }
-- ***********************************************************************
-- PXE Boot
-- ***********************************************************************
networkPXEboot OBJECT-TYPE
SYNTAX INTEGER {
networkPXEBootDisabled(0),
networkPXEBootEnabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Modify the system's boot sequence for the next system restart
in order to attempt a PXE/DHCP network boot. The system's boot
sequence(set via the BIOS settings) will be altered only if the
system is not under PAP (Privileged Access Protection)."
::= { generalSystemSettings 2 }
-- ***********************************************************************
-- System Power Control
-- ***********************************************************************
-- ***********************************************************************
-- Power Statistics for the system
-- ***********************************************************************
powerStatistics OBJECT IDENTIFIER ::= { systemPower 1 }
currentSysPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
poweredOff(0),
sleepS3(1),
poweredOn(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates if the system is currently powered on, off, or in sleep state."
::= { powerStatistics 1 }
powerOnHours OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of hours the system has been powered on."
::= { powerStatistics 2 }
restartCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times the system has been restarted."
::= { powerStatistics 3 }
systemState OBJECT-TYPE
SYNTAX INTEGER {
systemPowerOfforStateUnknown(0),
systemPowerOnorStartingUEFI(1),
systemInUEFI(2),
uEFIErrorDetected(3),
bootingOSorInUnsupportedOS(4),
oSBooted(5),
suspendToRAM(6),
systemInSetup(7),
systemInLXPMMaintenanceMode(8),
systemInMemoryTest(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Shows the current operational state of the system."
::= { powerStatistics 4 }
-- ***********************************************************************
-- System Power off configuration
-- ***********************************************************************
powerSysConfig OBJECT IDENTIFIER ::= { systemPower 2 }
powerSysOffDelay OBJECT-TYPE
SYNTAX INTEGER {
noDelay(0),
oneHalfMinute(30),
oneMinute(60),
twoMinutes(120),
threeMinutes(180),
fourMinutes(240),
fiveMinute(300),
sevenAndHalfMinutes(450),
tenMinutes(600),
fifteenMinutes(900),
twentyMinutes(1200),
thirtyMinutes(1800),
oneHour(3600),
twoHours(7200)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of 1 second interval the XCC will
wait before powering off the system."
::= { powerSysConfig 1 }
powerSysOnClockSetting OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The clock setting used to determine when the XCC
will power on the system.
For example the value '03/04/2001,06:00' means that the system will power on
March 4, 2001 at 06:00AM. "
::= { powerSysConfig 2 }
-- ***********************************************************************
-- Schedule Power Actions
-- ***********************************************************************
powerCyclingSchedule OBJECT IDENTIFIER ::= { systemPower 5 }
schedulePowerOffWithOsShutdown OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Off the system after performing a OS shutdown at specified time and day of the week.
Example: Monday,09:00, To reset, the value as Never,00:00."
::= { powerCyclingSchedule 1 }
schedulePowerOnSystem OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power On the system at specified time and day of the week.
Example: Monday,09:00. To reset, the value as Never,00:00."
::= { powerCyclingSchedule 2 }
-- ***********************************************************************
-- Service Advisor
--
-- Note: Support is not available on all XCC based Servers
--
-- ***********************************************************************
autoCallHomeSetup OBJECT IDENTIFIER ::= { serviceAdvisor 1 }
acceptLicenseAgreement OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Accept Terms and Conditions of Service Advisor. The user will have to accept the terms and conditions
before Service Advisor can send diagnostic data to support personnel. If XCC configuration
is reset to defaults, the user will have to accept the terms and conditions again before they can
enable Service Advisor. For more information, please refer to the BladeCenter User's Guide.
It will return disabled(0) or enabled(1), depending upon the current state. "
::= {autoCallHomeSetup 1}
serviceAdvisorEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Disable/Enable Call Home Support. The User Agreement must be accepted and the contact information
must be set before the Call Home Support function of Service Advisor can be enabled."
::= {autoCallHomeSetup 2}
serviceSupportCenter OBJECT IDENTIFIER ::= {serviceAdvisor 2}
lenovoSupportCenter OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The country code for the Support Center. 2 character ISO country code."
::= {serviceSupportCenter 1}
contactInformation OBJECT IDENTIFIER ::= {serviceAdvisor 3}
companyName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The organization/company name of the contact person. 1-30 characters."
::= {contactInformation 1}
contactName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the contact person.1-30 characters."
::= {contactInformation 2}
phoneNumber OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phone of the contact person. 5-30 characters."
::= {contactInformation 3}
emailAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The email of the contact person. It must contain '@' and dot '.' in form userid@hostname (30 characters maximum).
The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters.
The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items.
Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters."
::= {contactInformation 4}
address OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The address of the machine location. The information in this field should be of sufficient detail to allow someone to
quickly find the chassis when necessary. 1-30 characters."
::= {contactInformation 5}
city OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The city of the machine location. 1-30 characters."
::= {contactInformation 6}
state OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the machine location. 2-3 characters."
::= {contactInformation 7}
postalCode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid."
::= {contactInformation 8}
phoneExtension OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phone extension of the contact person. 30 characters maximum."
::= {contactInformation 9}
altContactName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the alternate contact person. 1-30 characters."
::= {contactInformation 10}
altPhoneNumber OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phone of the alternate contact person. 5-30 characters."
::= {contactInformation 11}
altPhoneExtension OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phone extension of the alternate contact person. 30 characters maximum."
::= {contactInformation 12}
altEmailAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (30 characters maximum).
The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters.
The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items.
Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters."
::= {contactInformation 13}
machineLocationPhoneNumber OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phone of the physical location where the compuer system resides. 5-30 characters."
::= {contactInformation 14}
httpProxyConfig OBJECT IDENTIFIER ::= {serviceAdvisor 4}
httpProxyEnable OBJECT-TYPE
SYNTAX INTEGER{
disabled(0),
enabled(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Disable/Enable of the HTTP Proxy. HTTP Proxy is used by the XCC when it is not connected to the internet directly."
::= {httpProxyConfig 1}
httpProxyLocation OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Fully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters."
::= {httpProxyConfig 2}
httpProxyPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the HTTP Proxy. An integer value from 1 to 65535."
::= {httpProxyConfig 3}
httpProxyUserName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"User Name of the HTTP Proxy. A maximum of 30 characters string without spaces."
::= {httpProxyConfig 4}
httpProxyPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Password of the HTTP Proxy. A maximum of 15 characters string without spaces."
::= {httpProxyConfig 5}
activityLogs OBJECT IDENTIFIER ::= { serviceAdvisor 5}
activityLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActivityLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"
Table of Service Advisor Activity Log entries information. This table displays events that were generated
by the system or user that are called home. The entries are displayed in reverse chronological order
(most recent call home entry first). For any events that happen with same Date/Time, only one event will be
called home. If a call home event that is already in the activity log is triggered again on the same event
source, it will not be called home again unless the prior entry has been acknowledged as corrected or, in the
case of XCC, 120 hours (5 days) have passed since it initially occurred and was called home."
::= { activityLogs 1 }
activityLogEntry OBJECT-TYPE
SYNTAX ActivityLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"
Activity Log table entry. Each entry has the result of the call-home attempt,
the service number assigned for the issue by the Support Center, the event ID, event source, date and
time that event occured, and a text message.
"
INDEX { activityLogIndex }
::= { activityLogTable 1 }
ActivityLogEntry ::= SEQUENCE {
activityLogIndex INTEGER,
activityLogString OCTET STRING,
activityLogAcknowledge INTEGER,
activityLogAttribute OCTET STRING
}
activityLogIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Activity Log index number.
For consistent results, view as a table and not as individual entries."
::= { activityLogEntry 1 }
activityLogString OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A string of data detailing one Activity Log entry. The text message is from the original entry in the event log.
For consistent results, view as a table and not as individual entries."
::= { activityLogEntry 2 }
activityLogAcknowledge OBJECT-TYPE
SYNTAX INTEGER{
no(0),
yes(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to
certain events to indicate their awareness of the issue. Checking the acknowledge flag will not cause the event to be removed
from the log or close the ticket at the Support Center. This log is not cleared, so the acknowledge flag can be used to indicate a problem
can be ignored. This field can be also used to override the 120 hour (5 day) filtering of reports via the Support Center or FTP/TFTP Server
of Service Data.
For consistent results, view as a table and not as individual entries."
::= { activityLogEntry 3 }
activityLogAttribute OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"
A string of data detailing one Activity Log entry's attribute. It contains states of both calling the Support Center and FTP/TFTP Server.
A PENDING indicates that the system is preparing for the event to be called home by collecting data about the systems state. A SUCCESS state
indicates that the problem was successfully transmitted to the Support Center or FTP/TFTP Server. A DISABLED state indicates that Service Advisor
has disabled calling the Support Center or FTP/TFTP Server while the hardware event is detected. A NOT SENT state indicates that the serviceable
event was not sent to prevent the same event from being sent repeatedly. The FAILED state indicates that the attempt
to transmit the event information was not successful. Additional information may be found in the Event Log.
The service number is similar to a ticket number that can be used as a reference to the issue reported by the machine
when contacting the Support Center. The event ID, event source, date and time are all information from the original entry in the event log.
The acknowledged as corrected field is a reminder to certain events to indicate their awareness of the issue.
For consistent results, view as a table and not as individual entries."
::= { activityLogEntry 4 }
-- ********************************************************************************
-- autoftp
-- ********************************************************************************
--
autoFTPSetup OBJECT IDENTIFIER ::= { serviceAdvisor 6 }
autoFTPCallMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
ftp(1),
tftp(2),
sftp(3)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field specifies the automated problem reporting mode. Automated problem reporting mode allows the XCC to automatically put
service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time,
only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event
can be sent for the same failed component."
::= { autoFTPSetup 1 }
autoFTPCallAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address."
::= { autoFTPSetup 2 }
autoFTPCallPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field specifies the port on remote FTP/TFTP server for data transmission."
::= { autoFTPSetup 3 }
autoFTPCallUserID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field specifies the user account to login remote FTP server."
::= { autoFTPSetup 4 }
-- ********************************************************************************
-- Call Home Exclusion List
-- ********************************************************************************
callHomeExclusionEvents OBJECT IDENTIFIER ::= { serviceAdvisor 7 }
readCallHomeExclusionEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF ReadCallHomeExclusionEventEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Call Home Exclusion Event entries information."
::= { callHomeExclusionEvents 1 }
readCallHomeExclusionEventEntry OBJECT-TYPE
SYNTAX ReadCallHomeExclusionEventEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Call Home Exclusion Event table entry"
INDEX { readCallHomeExclusionEventIndex }
::= { readCallHomeExclusionEventTable 1 }
ReadCallHomeExclusionEventEntry ::= SEQUENCE {
readCallHomeExclusionEventIndex INTEGER,
readCallHomeExclusionEventID OCTET STRING
}
readCallHomeExclusionEventIndex OBJECT-TYPE
SYNTAX INTEGER (1..1000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index number of one Call Home Exclusion Event.
For consistent results, view as a table and not as individual entries."
::= { readCallHomeExclusionEventEntry 1 }
readCallHomeExclusionEventID OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Event ID of one Call Home Exclusion Event entry.
For consistent results, view as a table and not as individual entries."
::= { readCallHomeExclusionEventEntry 2 }
END