mibs/MIBS/linksys/LINKSYS-POE-MIB

377 lines
12 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
LINKSYS-POE-MIB DEFINITIONS ::= BEGIN
-- Title: Linksys LOCALIZATION ROS
-- This Private MIB is enhancement for rfc3621.txt - Power Ethernet Mib
-- Version: 7.50
-- Date: 28 Nov 2005
IMPORTS
rnd FROM LINKSYS-MIB
DisplayString, TruthValue FROM SNMPv2-TC
OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI;
rlPoe MODULE-IDENTITY
LAST-UPDATED "200911260000Z"
ORGANIZATION "Linksys."
CONTACT-INFO
"Linksys.com"
DESCRIPTION
"Add a new field in the PoE MIB to indicate Max power allocation allowed"
REVISION "201006020000Z"
DESCRIPTION
"The private MIB module definition for Power Over Ethernet."
REVISION "200911260000Z"
DESCRIPTION
"Initial revision."
::= { rnd 108 }
rlPethPsePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The table listing additional information for Power Over Ethernet ports."
::= {rlPoe 1 }
rlPethPsePortEntry OBJECT-TYPE
SYNTAX RlPethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the rlPethPsePortTable."
INDEX { rlPethPsePortGroupIndex , rlPethPsePortIndex }
::= {rlPethPsePortTable 1 }
RlPethPsePortEntry ::= SEQUENCE {
rlPethPsePortGroupIndex INTEGER,
rlPethPsePortIndex INTEGER,
rlPethPsePortOutputVoltage INTEGER,
rlPethPsePortOutputCurrent INTEGER,
rlPethPsePortOutputPower INTEGER,
rlPethPsePortPowerLimit INTEGER,
rlPethPsePortStatus INTEGER,
rlPethPsePortStatusDescription DisplayString,
rlPethPsePortOperPowerLimit INTEGER,
rlPethPsePortSupportPoePlus TruthValue,
rlPethPsePortTimeRangeName DisplayString,
rlPethPsePortOperStatus TruthValue,
rlPethPsePortMaxPowerAllocAllowed INTEGER,
rlPethPsePortSupportPoe TruthValue
}
rlPethPsePortGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices.
Furthermore, the same value MUST be used in this variable,
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
to refer to a given box in a stack or module in the rack."
::= { rlPethPsePortEntry 1 }
rlPethPsePortIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable uniquely identifies the power Ethernet PSE
port within group pethPsePortGroupIndex to which the
power Ethernet PSE entry is connected."
::= { rlPethPsePortEntry 2 }
rlPethPsePortOutputVoltage OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates on the output voltage level in milli volts from rlPethPsePortIndex."
::= { rlPethPsePortEntry 3 }
rlPethPsePortOutputCurrent OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates on the output current level in milli amper from rlPethPsePortIndex."
::= { rlPethPsePortEntry 4 }
rlPethPsePortOutputPower OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates on the output power level in milli watts from rlPethPsePortIndex."
::= { rlPethPsePortEntry 5 }
rlPethPsePortPowerLimit OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates on the user configured power level in milli watts which is available from rlPethPsePortIndex."
::= { rlPethPsePortEntry 6 }
rlPethPsePortStatus OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates on the hardware status of rlPethPsePortIndex."
::= { rlPethPsePortEntry 7 }
rlPethPsePortStatusDescription OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the description of the hardware status of rlPethPsePortIndex."
::= { rlPethPsePortEntry 8 }
rlPethPsePortOperPowerLimit OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the maximum power level in milli watts which is available from rlPethPsePortIndex."
::= { rlPethPsePortEntry 9 }
rlPethPsePortSupportPoePlus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if the port supports poe plus."
::= { rlPethPsePortEntry 10 }
rlPethPsePortTimeRangeName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable is used to bind PoE port to time range."
::= { rlPethPsePortEntry 11 }
rlPethPsePortOperStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This Read-Only variable indicates PoE port current status affected by time range active/inactive and admin status."
::= { rlPethPsePortEntry 12 }
rlPethPsePortMaxPowerAllocAllowed OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the maximum power allocation allowed per port (including wire power loses) in milli-watts which is available from rlPethPsePortIndex."
::= { rlPethPsePortEntry 13 }
rlPethPsePortSupportPoe OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if the port is a poe port"
::= { rlPethPsePortEntry 14 }
rlPethMainPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The table listing additional read - only information for Power Over Ethernet."
::= {rlPoe 2 }
rlPethMainPseEntry OBJECT-TYPE
SYNTAX RlPethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the rlPethMainPseTable."
INDEX { rlPethMainPseGroupIndex }
::= {rlPethMainPseTable 1 }
RlPethMainPseEntry ::= SEQUENCE {
rlPethMainPseGroupIndex INTEGER,
rlPethMainPseSwVersion DisplayString,
rlPethMainPseHwVersion DisplayString,
rlPethMainPseHwType INTEGER,
rlPethMainPsePowerGuardBand INTEGER
}
rlPethMainPseGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices.
Furthermore, the same value MUST be used in this variable,
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
to refer to a given box in a stack or module in the rack."
::= { rlPethMainPseEntry 1 }
rlPethMainPseSwVersion OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable identifies the MCU SW version."
::= { rlPethMainPseEntry 2 }
rlPethMainPseHwVersion OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable identifies the MCU HW version."
::= { rlPethMainPseEntry 3 }
rlPethMainPseHwType OBJECT-TYPE
SYNTAX INTEGER {
enhanced(1),
plus(2),
auto(3),
nonPoe(4),
enhancedPlus(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable identifies the MCU HW type (enhanced, plus, none)."
::= { rlPethMainPseEntry 4 }
rlPethMainPsePowerGuardBand OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable identifies the guard band in [W] for not connecting
additional ports."
::= { rlPethMainPseEntry 5 }
rlPethPowerPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlPethPowerPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The table listing additional read-write information for Power Over Ethernet."
::= {rlPoe 3 }
rlPethPowerPseEntry OBJECT-TYPE
SYNTAX RlPethPowerPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the rlPethPowerPseTable."
INDEX { rlPethPowerPseGroupIndex }
::= {rlPethPowerPseTable 1 }
RlPethPowerPseEntry ::= SEQUENCE {
rlPethPowerPseGroupIndex INTEGER,
rlPethPowerPsePower INTEGER,
rlPethPowerPseRpsPower INTEGER,
rlPethPowerPsePowerManagementMode INTEGER,
rlPethPowerPsedisconnectMethod INTEGER,
rlPethPowerPseTemperatureSensor INTEGER,
rlPethPowerPseInrushTestEnabled INTEGER
}
rlPethPowerPseGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices.
Furthermore, the same value MUST be used in this variable,
PethPowerPseGroupIndex, and pethNotificationControlGroupIndex
to refer to a given box in a stack or module in the rack."
::= { rlPethPowerPseEntry 1 }
-- depricated
rlPethPowerPsePower OBJECT-TYPE
SYNTAX INTEGER {
none(0),
ps1(1),
ps2(2),
ps3(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable identifies the maximum power in [W] supplied by PSE."
::= { rlPethPowerPseEntry 2 }
-- depricated
rlPethPowerPseRpsPower OBJECT-TYPE
SYNTAX INTEGER {
none(0),
rps1(1),
rps2(2),
rps3(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable identifies the maximum power in [W] supplied by PSE + RPS."
::= { rlPethPowerPseEntry 3 }
rlPethPowerPsePowerManagementMode OBJECT-TYPE
SYNTAX INTEGER {
portlimit(0),
classlimit(5),
maxlimit(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable identifies power management mode."
::= { rlPethPowerPseEntry 4 }
rlPethPowerPsedisconnectMethod OBJECT-TYPE
SYNTAX INTEGER {
lowestpriority(0),
nextport(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable identifies disconnect method. "
::= { rlPethPowerPseEntry 5 }
rlPethPowerPseTemperatureSensor OBJECT-TYPE
SYNTAX INTEGER (-200..200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable identifies the pd temperature sensor. "
::= { rlPethPowerPseEntry 6 }
rlPethPowerPseInrushTestEnabled OBJECT-TYPE
SYNTAX INTEGER {
enabled(0),
disabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable identifies if HW inrush test will be disabled.
by default HW inrush test is enabled."
::= { rlPethPowerPseEntry 7 }
END