ALCATEL-IND1-INLINE-POWER-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, NOTIFICATION-TYPE
FROM SNMPv2-SMI
pethPsePortEntry, pethMainPseEntry
FROM POWER-ETHERNET-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
softentIND1InLinePower, pethTraps
FROM ALCATEL-IND1-BASE;
alcatelIND1INLINEPOWERMIB MODULE-IDENTITY
LAST-UPDATED "200704030000Z"
ORGANIZATION "Alcatel-Lucent"
CONTACT-INFO
"Please consult with Customer Service to ensure the most appropriate
version of this document is used with the products in question:
Alcatel-Lucent, Enterprise Solutions Division
(Formerly Alcatel Internetworking, Incorporated)
26801 West Agoura Road
Agoura Hills, CA 91301-5122
United States Of America
Telephone: North America +1 800 995 2696
Latin America +1 877 919 9526
Europe +31 23 556 0100
Asia +65 394 7933
All Other +1 818 878 4507
Electronic Mail: support@ind.alcatel.com
World Wide Web: http://alcatel-lucent.com/wps/portal/enterprise
File Transfer Protocol: ftp://ftp.ind.alcatel.com/pub/products/mibs"
DESCRIPTION
"This module describes an authoritative enterprise-specific Simple
Network Management Protocol (SNMP) Management Information Base (MIB):
Propietary InLinePower Extensions MIB definitions
The right to make changes in specification and other information
contained in this document without prior notice is reserved.
No liability shall be assumed for any incidental, indirect, special,
or consequential damages whatsoever arising from or related to this
document or the information contained herein.
Vendors, end-users, and other interested parties are granted
non-exclusive license to use this specification in connection with
management of the products for which it is intended to be used.
Copyright (C) 1995-2007 Alcatel-Lucent
ALL RIGHTS RESERVED WORLDWIDE"
REVISION "200704030000Z"
DESCRIPTION
"The latest version of this MIB Module."
::= { softentIND1InLinePower 1 }
alaPethObjects OBJECT IDENTIFIER ::= { alcatelIND1INLINEPOWERMIB 1 }
alaPethConformance OBJECT IDENTIFIER ::= { alcatelIND1INLINEPOWERMIB 2 }
alaPethMain OBJECT IDENTIFIER ::= { alcatelIND1INLINEPOWERMIB 3 }
-- PSE Objects
alaPethPsePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlaPethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of objects that augments the standard pethPsePortTable
entry by adding the alaPethPsePortPowerMaximum object."
::= { alaPethObjects 1 }
alaPethPsePortEntry OBJECT-TYPE
SYNTAX AlaPethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that display and control the power
characteristics of a power Ethernet PSE port."
AUGMENTS { pethPsePortEntry }
::= { alaPethPsePortTable 1 }
AlaPethPsePortEntry ::= SEQUENCE {
alaPethPsePortPowerMaximum
INTEGER,
alaPethPsePortPowerActual
INTEGER,
alaPethPsePortPowerStatus
INTEGER,
alaPethPsePortPowerClass
INTEGER
}
alaPethPsePortPowerMaximum OBJECT-TYPE
SYNTAX INTEGER ( 3000 .. 20000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls maximum amount of power per port."
::= { alaPethPsePortEntry 1 }
alaPethPsePortPowerActual OBJECT-TYPE
SYNTAX INTEGER ( 0 .. 30000 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the actual amount of power used by a port"
::= { alaPethPsePortEntry 2 }
alaPethPsePortPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
powerOn(1),
powerOff(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the power status of a port"
::= { alaPethPsePortEntry 3 }
alaPethPsePortPowerClass OBJECT-TYPE
SYNTAX INTEGER {
class0 (0),
class1 (1),
class2 (2),
class3 (3),
class4 (4),
class5 (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object controls class of poe device attached on a port.
class0 - The device can draw PD power from 0.44W to 12.95W and
current less than 5.0 mA.
class1 - The device can draw PD power from 0.44W to 3.84W and
current 10.5 mA.
class2 - The device can draw PD power from 3.84W to 6.49W and
current 12.95 mA.
class3 - The device can draw PD power from 6.49W to 12.95W and
current 28 mA.
class4 - This class is reserved for future use.
class5 - No Powered Device is connected to this POE port, or the
port is powered down."
::= { alaPethPsePortEntry 4 }
-- Main PSE Objects
alaPethMainPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlaPethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table augments the standard table PethMainPseTable by allowing the
admin status for a group to be set to on/off as well as
showing the values for the max power for that group."
::= { alaPethObjects 2 }
alaPethMainPseEntry OBJECT-TYPE
SYNTAX AlaPethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that display and control the Main power
of a PSE. "
AUGMENTS { pethMainPseEntry }
::= { alaPethMainPseTable 1 }
AlaPethMainPseEntry ::= SEQUENCE {
alaPethMainPseAdminStatus
INTEGER,
alaPethMainPseMaxPower
Integer32,
alaPethMainPsePriorityDisconnect
INTEGER,
alaPethMainPseCapacitorDetect
INTEGER,
alaPethMainPsePriority
INTEGER,
alaPethMainPseComboPort
INTEGER
}
alaPethMainPseAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object is used to set the status of the main PSE to ON or OFF."
::= { alaPethMainPseEntry 1 }
alaPethMainPseMaxPower OBJECT-TYPE
SYNTAX Integer32 (36..800)
UNITS "Watts"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum amount of power allowed for main PSE."
::= { alaPethMainPseEntry 2 }
alaPethMainPsePriorityDisconnect OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object is used to set the priority disconnect of the
main PSE to Enabled or Disable."
::= { alaPethMainPseEntry 3 }
alaPethMainPseCapacitorDetect OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object is used to enable or disable the PowerDsine
Capacitor detection method."
::= { alaPethMainPseEntry 4 }
alaPethMainPsePriority OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
high(2),
low(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object is set the power down priority for the slot"
::= { alaPethMainPseEntry 5 }
alaPethMainPseComboPort OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object is used to set the combo port option of the
main PSE to Enable or Disable."
::= { alaPethMainPseEntry 6 }
--
-- Conformance Section
--
alaPethCompliances OBJECT IDENTIFIER ::= { alaPethConformance 1 }
alaPethGroups OBJECT IDENTIFIER ::= { alaPethConformance 2 }
alaPethCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the
Alcatel Power Ethernet MIB."
MODULE -- this module
GROUP alaPethPsePortGroup
DESCRIPTION
"The alaPethPsePortGroup is mandatory for systems which
implement PSE ports."
GROUP alaPethMainPseGroup
DESCRIPTION
"The pethMainPseGroup is mandatory for systems which
implement main power supply within a PSE Device."
::= { alaPethCompliances 1 }
alaPethPseCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the PSE"
MODULE -- this module
MANDATORY-GROUPS {alaPethPsePortGroup, alaPethMainPseGroup}
::= { alaPethCompliances 2 }
alaPethPsePortGroup OBJECT-GROUP
OBJECTS {
alaPethPsePortPowerMaximum,
alaPethPsePortPowerActual,
alaPethPsePortPowerStatus,
alaPethPsePortPowerClass
}
STATUS current
DESCRIPTION
"The pethPsePortGroup is mandatory for systems which
implement PSE ports."
::= { alaPethGroups 1 }
alaPethMainPseGroup OBJECT-GROUP
OBJECTS {
alaPethMainPseAdminStatus,
alaPethMainPseMaxPower,
alaPethMainPsePriorityDisconnect,
alaPethMainPseCapacitorDetect,
alaPethMainPsePriority,
alaPethMainPseComboPort
}
STATUS current
DESCRIPTION
"Main PSE Objects. "
::= { alaPethGroups 2 }
-- Peth Main
alaPethMainTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlaPethMainEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of objects that augments the standard pethPsePortTable
entry by adding the alaPethPsePortPowerMaximum object."
::= { alaPethMain 1 }
alaPethMainEntry OBJECT-TYPE
SYNTAX AlaPethMainEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that display and control the power
characteristics of a power Ethernet PSE port."
INDEX { alaPethMainIndex }
::= { alaPethMainTable 1 }
AlaPethMainEntry ::= SEQUENCE {
alaPethMainIndex
Integer32,
alaPethMainPowerRedundancy
INTEGER
}
alaPethMainIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable uniquely identifies the group to which
power Ethernet PSE is connected.Group means (box in the stack,
module in a rack) and the value 1 MUST be used for non-modular
devices "
::= { alaPethMainEntry 1 }
alaPethMainPowerRedundancy OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls power supply redundancy."
::= { alaPethMainEntry 2 }
-- Notification Objects
alaPethNotificationObjects OBJECT IDENTIFIER ::= { alaPethObjects 3 }
pethSourceSlot OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number of generating entity."
::= { alaPethNotificationObjects 1 }
pethSourcePort OBJECT-TYPE
SYNTAX INTEGER (1..48)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port number of generating entity."
::= { alaPethNotificationObjects 2 }
-- NOTIFICATIONS
pethPwrSupplyConflict NOTIFICATION-TYPE
OBJECTS {
pethSourceSlot
}
STATUS current
DESCRIPTION
"Power supply type conflict trap."
::= { pethTraps 0 1 }
pethPwrSupplyNotSupported NOTIFICATION-TYPE
OBJECTS {
pethSourceSlot
}
STATUS current
DESCRIPTION
"Power supply not supported trap."
::= { pethTraps 0 2 }