ALCATEL-IND1-STACK-MANAGER-MIB DEFINITIONS ::= BEGIN
IMPORTS
NOTIFICATION-TYPE,
MODULE-IDENTITY,
OBJECT-TYPE,
Counter32 FROM SNMPv2-SMI
TEXTUAL-CONVENTION FROM SNMPv2-TC
RowStatus FROM SNMPv2-TC
InterfaceIndex FROM IF-MIB
softentIND1StackMgr FROM ALCATEL-IND1-BASE
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF ;
alcatelIND1StackMgrMIB MODULE-IDENTITY
LAST-UPDATED "200902060000Z"
ORGANIZATION "Alcatel-Lucent"
CONTACT-INFO
"Please consult with Customer Service to ensure the most appropriate
version of this document is used with the products in question:
Alcatel-Lucent, Enterprise Solutions Division
(Formerly Alcatel Internetworking, Incorporated)
26801 West Agoura Road
Agoura Hills, CA 91301-5122
United States Of America
Telephone: North America +1 800 995 2696
Latin America +1 877 919 9526
Europe +31 23 556 0100
Asia +65 394 7933
All Other +1 818 878 4507
Electronic Mail: support@ind.alcatel.com
World Wide Web: http://alcatel-lucent.com/wps/portal/enterprise
File Transfer Protocol: ftp://ftp.ind.alcatel.com/pub/products/mibs"
DESCRIPTION
"This module describes an authoritative enterprise-specific Simple
Network Management Protocol (SNMP) Management Information Base (MIB):
For the Birds Of Prey Product Line
Stack Manager
The right to make changes in specification and other information
contained in this document without prior notice is reserved.
No liability shall be assumed for any incidental, indirect, special, or
consequential damages whatsoever arising from or related to this
document or the information contained herein.
Vendors, end-users, and other interested parties are granted
non-exclusive license to use this specification in connection with
management of the products for which it is intended to be used.
Copyright (C) 1995-2007 Alcatel-Lucent
ALL RIGHTS RESERVED WORLDWIDE"
REVISION "200902060000Z" -- Feb 06, 2009
DESCRIPTION "Added alaStackMgrOperStackingMode and alaStackMgrAdminStackingMode
objects.
Added AlaStackMgrStackingMode TEXTUAL-CONVENTION."
REVISION "200704030000Z" -- Apr 02, 2007
DESCRIPTION "Updated copyright information."
REVISION "200507150000Z" -- Jul 15, 2005
DESCRIPTION "New trap alaStackMgrBadMixTrap has been added.
AlaStackMgrSlotState & AlaStackMgrLinkNumber textual convention
have been modified."
REVISION "200407010000Z" -- Jul 01, 2004
DESCRIPTION "Updates on definitions for link states.
Updates on pass through slot range."
REVISION "200404230000Z" -- Apr 23, 2004
DESCRIPTION "New trap alaStackMgrOutOfPassThruSlotsTrap has been added."
REVISION "200404080000Z" -- Apr 08, 2004
DESCRIPTION "alaStackMgrPassThruTrap has been split in three traps to assure
backwards compatibility with previous releases of the Birds Of
Prey products."
REVISION "200404040000Z" -- Apr 04, 2004
DESCRIPTION "-Command action and command status objects added to the chassis table.
-Link state textual conventions have been updated."
REVISION "200403220000Z" -- Mar 23, 2004
DESCRIPTION "Objects to handle information about token usage."
REVISION "200403080000Z" -- Mar 08, 2004
DESCRIPTION "Objects to support the pass through mode added."
REVISION "200108270000Z" -- Aug 27, 2001
DESCRIPTION "Addressing discrepancies with Alcatel Standard."
::= { softentIND1StackMgr 1 }
alcatelIND1StackMgrMIBObjects OBJECT IDENTIFIER ::= { alcatelIND1StackMgrMIB 1 }
alcatelIND1StackMgrMIBConformance OBJECT IDENTIFIER ::= { alcatelIND1StackMgrMIB 2 }
alcatelIND1StackMgrTrapObjects OBJECT IDENTIFIER ::= { alcatelIND1StackMgrMIB 3 }
alaStackMgrTraps OBJECT IDENTIFIER ::= { alcatelIND1StackMgrMIB 4 }
AlaStackMgrLinkNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Lists the port numbers that the stackable ports can hold.
Also the values are the same as the one marked on the Stack chassis pannel.
These values are hardware dependent as follows:
- First generation stackable switches - 24 ports: linkA27=27, linkB28=28,
- First generation stackable switches - 48 ports: linkA51=51, linkB52=52,
- 1st version of 2nd generation stackable switches : linkA31=31, linkB32=32.
- 2nd version of 2nd generation stackable switches 24-port : linkA25=25, linkB26=26,
- 2nd version of 2nd generation stackable switches 48-port : linkA29=29, linkB30=30."
SYNTAX INTEGER { linkA27(27),
linkB28(28),
linkA51(51),
linkB52(52),
linkA31(31),
linkB32(32),
linkA25(25),
linkB26(26),
linkA29(29),
linkB30(30),
linkA(1),
linkB(2) }
AlaStackMgrNINumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The numbers allocated for the stack NIs are as follows:
- 0 = invalid slot number;
- 1..8 = valid and assigned slot numbers corresponding values from the entPhysicalTable;
- 1001..1008 = switches operating in pass through mode;
- 255 = unassigned slot number."
SYNTAX INTEGER (0..1008)
AlaStackMgrLinkStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Provides the logical stack link status. The logical link is
considered operational if the physical link is operational and communication
with the adjacent switch is active. The possible values are:
- up(1),
- down(2)."
SYNTAX INTEGER { up(1), down(2) }
AlaStackMgrSlotRole ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Indicates the role of each switch within the stack as follows:
- unassigned(0),
- primary(1),
- secondary(2),
- idle(3),
- standalone(4),
- passthrough(5)"
SYNTAX INTEGER { unassigned (0),
primary (1),
secondary (2),
idle (3),
standalone (4),
passthrough (5) }
AlaStackMgrStackStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Indicates whether the stack ring is or not in loop as follows:
- loop(1),
- noloop(2)"
SYNTAX INTEGER { loop(1), noloop(2) }
AlaStackMgrSlotState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Current operational state of a stack element as follows:
- running(1) : switch is fully operational,
- duplicateSlot(2): switch operates in pass through mode due to slot duplication,
- clearedSlot(3) : switch operates in pass through mode upon management command,
- outOfSlots(4) : switch operates in pass through because the maximum number of
allowed stackable swicthes has been reached,
- outOfTokens(5) : switch operates in pass through mode because no tokens are
available to be assigned.
- badMix (6) : switch operates in pass through mode because it's not compatible
with the existing stack."
SYNTAX INTEGER { running (1),
duplicateSlot (2),
clearedSlot (3),
outOfSlots (4),
outOfTokens (5),
badMix (6) }
AlaStackMgrCommandAction ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Identifies which of the following actions is to be performed:
- notSiginificant(0) : no action,
- clearSlot(1) : saved slot number will be removed from persistent database,
- clearSlotImmediately : saved slot number will be cleared and change will be in effect
right away causing the switch to enter in pass through mode,
- reloadAny(3) : reboot an element regardless of its operational mode,
- reloadPassThru(4) : reboot an element that is operating in pass thru mode."
SYNTAX INTEGER { notSignificant(0),
clearSlot(1),
clearSlotImmediately(2),
reloadAny(3),
reloadPassThru(4) }
AlaStackMgrCommandStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Identifies the current status of the last action command
received as follows:
- notSignificant(0),
- clearSlotInProgress(1),
- clearSlotFailed(2),
- clearSlotSuccess(3),
- setSlotInProgress(4),
- setSlotFailed(5),
- setSlotSuccess(6)."
SYNTAX INTEGER { notSignificant(0),
clearSlotInProgress(1),
clearSlotFailed(2),
clearSlotSuccess(3),
setSlotInProgress(4),
setSlotFailed(5),
setSlotSuccess(6) }
AlaStackMgrStackingMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Stacking mode, which specifies the ability of a switch
to be part of a set of switches or virtual chassis:
- stackable(1) :the switch may be stacked with other
switches in the same virtual chassis.
- standalone(2) :the switch is not allowed to be stacked together
with other switches."
SYNTAX INTEGER {
stackable(1),
standalone(2)
}
-----------------------------------------------
-- Stack Chassis Table
-----------------------------------------------
alaStackMgrChassisTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlaStackMgrChassisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Maintains a list with information about all the switches
that participate on the stack herein refered to as chassis."
::= { alcatelIND1StackMgrMIBObjects 1 }
alaStackMgrChassisEntry OBJECT-TYPE
SYNTAX AlaStackMgrChassisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Each entry corresponds to a chassis and lists its role and
neighbors in the stack."
INDEX { alaStackMgrSlotNINumber }
::= { alaStackMgrChassisTable 1 }
AlaStackMgrChassisEntry ::= SEQUENCE {
alaStackMgrSlotNINumber AlaStackMgrNINumber,
alaStackMgrSlotCMMNumber INTEGER,
alaStackMgrChasRole AlaStackMgrSlotRole,
alaStackMgrLocalLinkStateA AlaStackMgrLinkStatus,
alaStackMgrRemoteNISlotA AlaStackMgrNINumber,
alaStackMgrRemoteLinkA AlaStackMgrLinkNumber,
alaStackMgrLocalLinkStateB AlaStackMgrLinkStatus,
alaStackMgrRemoteNISlotB AlaStackMgrNINumber,
alaStackMgrRemoteLinkB AlaStackMgrLinkNumber,
alaStackMgrChasState AlaStackMgrSlotState,
alaStackMgrSavedSlotNINumber AlaStackMgrNINumber,
alaStackMgrCommandAction AlaStackMgrCommandAction,
alaStackMgrCommandStatus AlaStackMgrCommandStatus,
alaStackMgrOperStackingMode AlaStackMgrStackingMode,
alaStackMgrAdminStackingMode AlaStackMgrStackingMode
}
alaStackMgrSlotNINumber OBJECT-TYPE
SYNTAX AlaStackMgrNINumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Numbers allocated for the stack NIs as follows:
- 0: invalid slot number
- 1..8: valid and assigned slot numbers corresponding to values from the entPhysicalTable
- 1001..1008: swicthes operating in pass through mode
- 255: unassigned slot number."
::= { alaStackMgrChassisEntry 1 }
alaStackMgrSlotCMMNumber OBJECT-TYPE
SYNTAX INTEGER (0..72)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The numbers allocated for the stack CMMs are from 65..72 or 0 if not present"
::= { alaStackMgrChassisEntry 2 }
alaStackMgrChasRole OBJECT-TYPE
SYNTAX AlaStackMgrSlotRole
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current role of the chassis as follows:
- unassigned(0),
- primary(1),
- secondary(2),
- idle(3),
- standalone(4),
- passthrough(5)."
::= { alaStackMgrChassisEntry 3 }
alaStackMgrLocalLinkStateA OBJECT-TYPE
SYNTAX AlaStackMgrLinkStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "1 indicates that the stacking link A is up, which means it knows its adjacent node.
2 indicates that the stacking link A is inactive and RemoteNISlotA and RemoteLinkA are not significants."
::= { alaStackMgrChassisEntry 4 }
alaStackMgrRemoteNISlotA OBJECT-TYPE
SYNTAX AlaStackMgrNINumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION " This is the remote NI slot seen by the current NI through its stacking link A.
The numbers allocated for the Stack NIs are 1..8, 1001..1008 or 0 if not present"
::= { alaStackMgrChassisEntry 5 }
alaStackMgrRemoteLinkA OBJECT-TYPE
SYNTAX AlaStackMgrLinkNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the remote link of the remote NI slot seen through the stacking link A.
The values for these ports are platform dependent. The possible values are:
- 0: not present
- linkA: 25, 27, 29, 31 or 51
- linkB: 26, 28, 30, 32 or 52."
::= { alaStackMgrChassisEntry 6 }
alaStackMgrLocalLinkStateB OBJECT-TYPE
SYNTAX AlaStackMgrLinkStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "1 indicates that the stacking link B is up, which means it knows its adjacent node.
2 indicates that the stacking link B is inactive and RemoteNISlotB and RemoteLinkB are not significants."
::= { alaStackMgrChassisEntry 7 }
alaStackMgrRemoteNISlotB OBJECT-TYPE
SYNTAX AlaStackMgrNINumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION " This is the remote NI slot seen by the current NI through its stacking link B.
The numbers allocated for the Stack NIs are 1..8, 1001..1008 or 0 if not present"
::= { alaStackMgrChassisEntry 8 }
alaStackMgrRemoteLinkB OBJECT-TYPE
SYNTAX AlaStackMgrLinkNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the remote link of the remote NI slot seen through the stacking link B.
The values for these ports are platform dependent. The possible values are:
- 0: not present
- linkA: 25, 27, 29, 31 or 51
- linkB: 26, 28, 30, 32 or 52."
::= { alaStackMgrChassisEntry 9 }
alaStackMgrChasState OBJECT-TYPE
SYNTAX AlaStackMgrSlotState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This current state of the chassis: running (1), duplicateSlot (2), clearedSlot (3),
outOfSlots (4), outOfTokens (5), or badMix (6)."
::= { alaStackMgrChassisEntry 10 }
alaStackMgrSavedSlotNINumber OBJECT-TYPE
SYNTAX AlaStackMgrNINumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Slot number stored in persistent memory that will be in effect if the stack
element reboots. Only slot numbers in the range 1..8 are allowed."
::= { alaStackMgrChassisEntry 11 }
alaStackMgrCommandAction OBJECT-TYPE
SYNTAX AlaStackMgrCommandAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object identifies which of the following Actions is to be performed:
clearSlot(1), clearSlotImmediately (2) or reload (3). Whenever a new command is received,
the value of the object alaStackMgrCommandStatus will be updated accordingly."
::= { alaStackMgrChassisEntry 12 }
alaStackMgrCommandStatus OBJECT-TYPE
SYNTAX AlaStackMgrCommandStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object provides the current status of last command received from the management
as follows: notSignificant(0), clearSlotInProgress(1), clearSlotFailed(2), clearSlotSuccess(3),
setSlotInProgress(4), setSlotFailed(5) or setSlotSuccess(6).
New commands are only accepted if the value of this object is different than setSlotInProgress
and clearSlotInProgress."
::= { alaStackMgrChassisEntry 13 }
alaStackMgrOperStackingMode OBJECT-TYPE
SYNTAX AlaStackMgrStackingMode
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object specifies the current running mode of the switch."
::= { alaStackMgrChassisEntry 14 }
alaStackMgrAdminStackingMode OBJECT-TYPE
SYNTAX AlaStackMgrStackingMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object specifies the stack mode atained on reload."
::= { alaStackMgrChassisEntry 15 }
----------------------------------------------------------
-- Stack Mgr Statistics Table
----------------------------------------------------------
alaStackMgrStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlaStackMgrStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Stack port statistics table."
::= { alcatelIND1StackMgrMIBObjects 2 }
alaStackMgrStatsEntry OBJECT-TYPE
SYNTAX AlaStackMgrStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " Stats table for stackable ports."
INDEX { alaStackMgrSlotNINumber, alaStackMgrStatLinkNumber}
::= { alaStackMgrStatsTable 1 }
AlaStackMgrStatsEntry ::= SEQUENCE {
alaStackMgrStatLinkNumber AlaStackMgrLinkNumber,
alaStackMgrStatPktsRx Counter32,
alaStackMgrStatPktsTx Counter32,
alaStackMgrStatErrorsRx Counter32,
alaStackMgrStatErrorsTx Counter32,
alaStackMgrStatDelayFromLastMsg INTEGER
}
alaStackMgrStatLinkNumber OBJECT-TYPE
SYNTAX AlaStackMgrLinkNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION " Local link refers to the stacking port on each slot.
The values of these ports are:
- linkA: 25, 27, 29, 31 or 51
- linkB: 26, 28, 30, 32 or 52."
::= { alaStackMgrStatsEntry 1 }
alaStackMgrStatPktsRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets recieved on this port."
::= { alaStackMgrStatsEntry 2 }
alaStackMgrStatPktsTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets transmitted on this port."
::= { alaStackMgrStatsEntry 3 }
alaStackMgrStatErrorsRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets in error - received on the port."
::= { alaStackMgrStatsEntry 4 }
alaStackMgrStatErrorsTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets in error - transmitted on the port."
::= { alaStackMgrStatsEntry 5 }
alaStackMgrStatDelayFromLastMsg OBJECT-TYPE
SYNTAX INTEGER ( 0 .. 2147483647 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The delay since the last message."
::= { alaStackMgrStatsEntry 6 }
----------------------------------------------------------
-- Stack Mgr Global Properties
----------------------------------------------------------
alaStackMgrStackStatus OBJECT-TYPE
SYNTAX AlaStackMgrStackStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the Stack is or not in Loop."
::= { alcatelIND1StackMgrMIBObjects 3 }
alaStackMgrTokensUsed OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the total number of tokens that have been allocated to all the
elements in the stack."
::= { alcatelIND1StackMgrMIBObjects 4 }
alaStackMgrTokensAvailable OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the total number of tokens that are still available and that
potentially may be allocated to elements of the stack."
::= { alcatelIND1StackMgrMIBObjects 5 }
-----------------------------------------------
-- Stack Static Route Table
-----------------------------------------------
alaStackMgrStaticRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlaStackMgrStaticRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Maintains a list with information about all the static
routes in the stack."
::= { alcatelIND1StackMgrMIBObjects 6 }
alaStackMgrStaticRouteEntry OBJECT-TYPE
SYNTAX AlaStackMgrStaticRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Each entry corresponds to a static route and lists its source and
destination in the stack."
INDEX { alaStackMgrStaticRouteSrcStartIf,alaStackMgrStaticRouteSrcEndIf,alaStackMgrStaticRouteDstStartIf,alaStackMgrStaticRouteDstEndIf}
::= { alaStackMgrStaticRouteTable 1 }
AlaStackMgrStaticRouteEntry ::= SEQUENCE {
alaStackMgrStaticRouteSrcStartIf InterfaceIndex,
alaStackMgrStaticRouteSrcEndIf InterfaceIndex,
alaStackMgrStaticRouteDstStartIf InterfaceIndex ,
alaStackMgrStaticRouteDstEndIf InterfaceIndex ,
alaStackMgrStaticRoutePort AlaStackMgrLinkNumber,
alaStackMgrStaticRoutePortState AlaStackMgrLinkStatus,
alaStackMgrStaticRouteStatus INTEGER,
alaStackMgrStaticRouteRowStatus RowStatus
}
alaStackMgrStaticRouteSrcStartIf OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The physical identification number for start source range of the static route"
::= { alaStackMgrStaticRouteEntry 1 }
alaStackMgrStaticRouteSrcEndIf OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The physical identification number for end source range of the static route"
::= { alaStackMgrStaticRouteEntry 2 }
alaStackMgrStaticRouteDstStartIf OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The physical identification number for start destination range of the static route"
::= { alaStackMgrStaticRouteEntry 3 }
alaStackMgrStaticRouteDstEndIf OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The physical identification number for end destination range of the static route"
::= { alaStackMgrStaticRouteEntry 4 }
alaStackMgrStaticRoutePort OBJECT-TYPE
SYNTAX AlaStackMgrLinkNumber
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This is the stack link to the destination NI slot .
The values for these ports are platform dependent. The possible values are:
- 0: not present
- linkA: 25, 27, 29, 31 or 51
- linkB: 26, 28, 30, 32 or 52.
Incase of static routesthe value is either 1(STACKA) or 2(STACKB)"
DEFVAL { 1 }
::= { alaStackMgrStaticRouteEntry 5 }
alaStackMgrStaticRoutePortState OBJECT-TYPE
SYNTAX AlaStackMgrLinkStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "1 indicates that the static route stacking link is up .
2 indicates that the stacking link is inactive."
::= { alaStackMgrStaticRouteEntry 6 }
alaStackMgrStaticRouteStatus OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether this static route is enabled or disabled ."
DEFVAL { on }
::= { alaStackMgrStaticRouteEntry 7 }
alaStackMgrStaticRouteRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this table entry.
"
::= { alaStackMgrStaticRouteEntry 8 }
-------------------------------------------------------
-- Stack Manager Trap Objects
-------------------------------------------------------
alaStackMgrTrapLinkNumber OBJECT-TYPE
SYNTAX AlaStackMgrLinkNumber
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Holds the link number, when the stack is not in loop."
::= { alcatelIND1StackMgrTrapObjects 1 }
alaStackMgrPrimary OBJECT-TYPE
SYNTAX AlaStackMgrNINumber
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Holds the slot number of the stack element that plays the role of Primary."
::= { alcatelIND1StackMgrTrapObjects 2 }
alaStackMgrSecondary OBJECT-TYPE
SYNTAX AlaStackMgrNINumber
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Holds the slot number of the stack element that plays the role of Secondary."
::= { alcatelIND1StackMgrTrapObjects 3 }
-------------------------------------------------------
-- Stack Manager Traps
-------------------------------------------------------
alaStackMgrDuplicateSlotTrap NOTIFICATION-TYPE
OBJECTS {
alaStackMgrSlotNINumber
}
STATUS current
DESCRIPTION
"The element specified by alaStackMgrSlotNINumber has the same slot number of
another element of the stack and it must relinquish its operational status
because it has a higher election key (up time, slot, mac).
The elements will be put in pass through mode."
::= { alaStackMgrTraps 0 1 }
alaStackMgrNeighborChangeTrap NOTIFICATION-TYPE
OBJECTS {
alaStackMgrStackStatus,
alaStackMgrSlotNINumber,
alaStackMgrTrapLinkNumber
}
STATUS current
DESCRIPTION
"Indicates whether the stack is in loop or not.
In case of no loop, alaStackMgrSlotNINumber and alaStackMgrTrapLinkNumber
indicate where the Stack is broken"
::= { alaStackMgrTraps 0 2 }
alaStackMgrRoleChangeTrap NOTIFICATION-TYPE
OBJECTS {
alaStackMgrPrimary,
alaStackMgrSecondary
}
STATUS current
DESCRIPTION
" Role Change Trap. Indicates that a new primary or secondary is elected."
::= { alaStackMgrTraps 0 3 }
alaStackMgrDuplicateRoleTrap NOTIFICATION-TYPE
OBJECTS {
alaStackMgrSlotNINumber,
alaStackMgrChasRole
}
STATUS current
DESCRIPTION
"The element identified by alaStackMgrSlotNINumber detected the presence of
two elements with the same primary or secondary role as specified by
alaStackMgrChasRole on the stack."
::= { alaStackMgrTraps 0 4 }
alaStackMgrClearedSlotTrap NOTIFICATION-TYPE
OBJECTS {
alaStackMgrSlotNINumber
}
STATUS current
DESCRIPTION
"The element identified by alaStackMgrSlotNINumber will enter the pass through
mode because its operational slot was cleared with immediate effect."
::= { alaStackMgrTraps 0 5 }
alaStackMgrOutOfSlotsTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"One element of the stack will enter the pass through mode because there
are no slot numbers available to be assigned to this element."
::= { alaStackMgrTraps 0 6 }
alaStackMgrOutOfTokensTrap NOTIFICATION-TYPE
OBJECTS {
alaStackMgrSlotNINumber
}
STATUS current
DESCRIPTION
"The element identified by alaStackMgrSlotNINumber will enter the pass through
mode because there are no tokens available to be assigned to this element."
::= { alaStackMgrTraps 0 7 }
alaStackMgrOutOfPassThruSlotsTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"There are no pass through slots available to be assigned to an element
that is supposed to enter the pass through mode."
::= { alaStackMgrTraps 0 8 }
alaStackMgrBadMixTrap NOTIFICATION-TYPE
OBJECTS {
alaStackMgrSlotNINumber
}
STATUS current
DESCRIPTION
"The element identified by alaStackMgrSlotNINumber will enter the pass through
mode because it is not compatible with the existing stack."
::= { alaStackMgrTraps 0 9 }
-- StackMgr Conformance
alcatelIND1StackMgrMIBGroups OBJECT IDENTIFIER ::=
{ alcatelIND1StackMgrMIBConformance 1 }
alcatelIND1StackMgrMIBCompliances OBJECT IDENTIFIER ::=
{ alcatelIND1StackMgrMIBConformance 2 }
alaStackMgrCfgMgrGroup OBJECT-GROUP
OBJECTS {
alaStackMgrSlotNINumber,
alaStackMgrSlotCMMNumber,
alaStackMgrChasRole,
alaStackMgrLocalLinkStateA,
alaStackMgrRemoteNISlotA,
alaStackMgrRemoteLinkA,
alaStackMgrLocalLinkStateB,
alaStackMgrRemoteNISlotB,
alaStackMgrRemoteLinkB,
alaStackMgrChasState,
alaStackMgrSavedSlotNINumber,
alaStackMgrCommandAction,
alaStackMgrCommandStatus,
alaStackMgrOperStackingMode,
alaStackMgrAdminStackingMode
}
STATUS current
DESCRIPTION
"A collection of objects providing information about
the topology of the stack ."
::= { alcatelIND1StackMgrMIBGroups 1 }
alaStackMgrNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { alaStackMgrDuplicateSlotTrap,
alaStackMgrNeighborChangeTrap,
alaStackMgrRoleChangeTrap,
alaStackMgrDuplicateRoleTrap,
alaStackMgrClearedSlotTrap,
alaStackMgrOutOfSlotsTrap,
alaStackMgrOutOfTokensTrap,
alaStackMgrOutOfPassThruSlotsTrap,
alaStackMgrBadMixTrap
}
STATUS current
DESCRIPTION
"A collection of notifications for signaling Stack manager events."
::= { alcatelIND1StackMgrMIBGroups 2 }
alcatelIND1StackMgrMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for device support of Stack Manager."
MODULE
MANDATORY-GROUPS {
alaStackMgrCfgMgrGroup,
alaStackMgrNotificationGroup
}
::= { alcatelIND1StackMgrMIBCompliances 1 }
END