mibs/MIBS/nokia/TIMETRA-LOG-MIB

6449 lines
232 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
TIMETRA-LOG-MIB DEFINITIONS ::= BEGIN
IMPORTS
InetAddress, InetAddressType
FROM INET-ADDRESS-MIB
SnmpAdminString,
SnmpMessageProcessingModel,
SnmpSecurityLevel
FROM SNMP-FRAMEWORK-MIB
snmpNotifyEntry
FROM SNMP-NOTIFICATION-MIB
MODULE-COMPLIANCE, NOTIFICATION-GROUP,
OBJECT-GROUP
FROM SNMPv2-CONF
sysDescr, sysObjectID
FROM SNMPv2-MIB
Counter32, Counter64, Integer32,
IpAddress, MODULE-IDENTITY,
NOTIFICATION-TYPE, OBJECT-TYPE,
Unsigned32
FROM SNMPv2-SMI
DateAndTime, DisplayString, RowStatus,
StorageType, TEXTUAL-CONVENTION,
TimeStamp, TruthValue
FROM SNMPv2-TC
TFilterAction, TFilterActionOrDefault
FROM TIMETRA-FILTER-MIB
timetraSRMIBModules, tmnxSRConfs,
tmnxSRNotifyPrefix, tmnxSRObjs
FROM TIMETRA-GLOBAL-MIB
THsmdaCounterIdOrZero,
THsmdaCounterIdOrZeroOrAll,
TItemDescription, TLNamedItemOrEmpty,
TNamedItem, TNamedItemOrEmpty, TQueueId,
TQueueIdOrAll, TmnxAccPlcyAACounters,
TmnxAccPlcyAASubAttributes,
TmnxAccPlcyOECounters,
TmnxAccPlcyOICounters,
TmnxAccPlcyPolicerECounters,
TmnxAccPlcyPolicerICounters,
TmnxAccPlcyQECounters,
TmnxAccPlcyQICounters, TmnxActionType,
TmnxAdminState, TmnxOperState,
TmnxSyslogFacility, TmnxSyslogSeverity,
TmnxUdpPort
FROM TIMETRA-TC-MIB
;
timetraLogMIBModule MODULE-IDENTITY
LAST-UPDATED "202007140000Z"
ORGANIZATION "Nokia"
CONTACT-INFO
"Nokia SROS Support
Web: http://www.nokia.com"
DESCRIPTION
"This document is the SNMP MIB module to manage and provision the Nokia
SROS Logging utility.
Copyright 2003-2020 Nokia. All rights reserved.
Reproduction of this document is authorized on the condition that
the foregoing copyright notice is included.
This SNMP MIB module (Specification) embodies Nokia's
proprietary intellectual property. Nokia retains
all title and ownership in the Specification, including any
revisions.
Nokia grants all interested parties a non-exclusive license to use and
distribute an unmodified copy of this Specification in connection with
management of Nokia products, and without fee, provided this copyright
notice and license appear on all copies.
This Specification is supplied 'as is', and Nokia makes no warranty,
either express or implied, as to the use, operation, condition, or
performance of the Specification."
REVISION "202007140000Z"
DESCRIPTION
"Rev 20 14 Jul 2020 00:00
Release 20 of the TIMETRA-LOG-MIB."
REVISION "201904010000Z"
DESCRIPTION
"Rev 19 1 April 2019 00:00
Release 19 of the TIMETRA-LOG-MIB."
REVISION "201706300000Z"
DESCRIPTION
"Rev 15.1 30 Jun 2017 00:00
15.1 release of the TIMETRA-LOG-MIB."
REVISION "201703010000Z"
DESCRIPTION
"Rev 15.0 01 Mar 2017 00:00
15.0 release of the TIMETRA-LOG-MIB."
REVISION "201601010000Z"
DESCRIPTION
"Rev 14.0 01 Jan 2016 00:00
14.0 release of the TIMETRA-LOG-MIB."
REVISION "201501010000Z"
DESCRIPTION
"Rev 13.0 01 Jan 2015 00:00
13.0 release of the TIMETRA-LOG-MIB."
REVISION "201401010000Z"
DESCRIPTION
"Rev 12.0 01 Jan 2014 00:00
12.0 release of the TIMETRA-LOG-MIB."
REVISION "201102010000Z"
DESCRIPTION
"Rev 9.0 01 Feb 2011 00:00
9.0 release of the TIMETRA-LOG-MIB."
REVISION "200902280000Z"
DESCRIPTION
"Rev 7.0 28 Feb 2009 00:00
7.0 release of the TIMETRA-LOG-MIB."
REVISION "200801010000Z"
DESCRIPTION
"Rev 6.0 01 Jan 2008 00:00
6.0 release of the TIMETRA-LOG-MIB."
REVISION "200701010000Z"
DESCRIPTION
"Rev 5.0 01 Jan 2007 00:00
5.0 release of the TIMETRA-LOG-MIB."
REVISION "200603150000Z"
DESCRIPTION
"Rev 4.0 15 Mar 2006 00:00
4.0 release of the TIMETRA-LOG-MIB."
REVISION "200501240000Z"
DESCRIPTION
"Rev 2.1 24 Jan 2005 00:00
2.1 release of the TIMETRA-LOG-MIB."
REVISION "200405270000Z"
DESCRIPTION
"Rev 2.1 27 May 2004 00:00
2.1 release of the TIMETRA-LOG-MIB."
REVISION "200401150000Z"
DESCRIPTION
"Rev 2.0 15 Jan 2004 00:00
2.0 release of the TIMETRA-LOG-MIB."
REVISION "200308150000Z"
DESCRIPTION
"Rev 1.2 15 Aug 2003 00:00
1.2 release of the TIMETRA-LOG-MIB."
REVISION "200301200000Z"
DESCRIPTION
"Rev 1.0 20 Jan 2003 00:00
1.0 Release of the TIMETRA-LOG-MIB."
REVISION "200111100000Z"
DESCRIPTION
"Rev 0.1 10 Nov 2001 00:00
Initial version of the TIMETRA-LOG-MIB."
::= { timetraSRMIBModules 12 }
TmnxPerceivedSeverity ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"ITU perceived severity values as per M.3100 and X.733"
SYNTAX INTEGER {
none (0),
cleared (1),
indeterminate (2),
critical (3),
major (4),
minor (5),
warning (6)
}
TmnxSyslogId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of TmnxSyslogId uniquely identifies an entry in the
tmnxSyslogTargetTable to be used for the syslog collector target
information when creating a log file where tmnxLogIdDestination has a
value of 'syslog (2)'."
SYNTAX Integer32 (1..40)
TmnxSyslogIdOrEmpty ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of TmnxSyslogIdOrEmpty uniquely identifies an entry in the
tmnxSyslogTargetTable to be used for the syslog collector target
information when creating a log file where tmnxLogIdDestination
has a value of 'syslog (2)'. The value of 0 is used when no
entry exists in the tmnxSyslogTargetTable."
SYNTAX Integer32 (0 | 1..40)
TmnxLogFileId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of TmnxLogFileId uniquely identifies a file-id to be
used when creating a log or accounting file. A value of zero (0)
indicates none specified and is invalid when used as an index
for the tmnxLogFileIdTable."
SYNTAX Integer32 (0..99)
TmnxLogFileType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of TmnxLogFileType indicates the type of information that
will be written to this file."
SYNTAX INTEGER {
none (0),
eventLog (1),
accountingPolicy (2)
}
TmnxLogIdIndex ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of tmnxLogIdIndex uniquely identifies an event stream log.
Note that 3 default TmnxLogIdEntry rows are created by the agent using
TmnxLogIdIndex values 99, 100 and 101."
SYNTAX Integer32 (1..101)
TmnxStgIndex ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of TmnxStgIndex uniquely identifies an event stream log. It
is the same as an TmnxLogIdIndex but with a limited range."
SYNTAX Integer32 (1..100)
TmnxCFlash ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of TmnxCFlash uniquely identifies a compact flash
module on the active CPM card. A value of zero (0) indicates
none specified."
SYNTAX Unsigned32
TmnxLogFilterId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of TmnxLogFilterId is the identification number of an
event log filter. The value of zero indicates none specified.
The value of zero (0) is invalid when used as an index for the
tmnxLogFilterTable. Filter entry 1001 is created by the agent."
SYNTAX Unsigned32 (0..1500)
TmnxLogFilterEntryId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of TmnxLogFilterEntryId is the identification number of an
event log filter entry."
SYNTAX Unsigned32 (1..999)
TmnxLogFilterOperator ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"When TmnxLogFilterOperator has a value of 'off', the item is not
matched. Otherwise the value of TmnxLogFilterOperator determines
the comparison operator to be used as the parameter match criterion."
SYNTAX INTEGER {
off (1),
equal (2),
notEqual (3),
lessThan (4),
lessThanOrEqual (5),
greaterThan (6),
greaterThanOrEqual (7)
}
TmnxEventNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Each log event type has a unique identifying number. This number is
unique within a particular software application, such as IP, MPLS,
OSPF, etc.; but it is not necessarily unique across different software
applications. That is MPLS event #1001 may be different from OSPF
event #1001."
SYNTAX Unsigned32
TmnxLogExRbkOperationType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of TmnxLogExRbkOperationType specifies the type of operation
being performed."
SYNTAX INTEGER {
unknown (0),
exec (1),
rollback (2),
vsd (3),
load (4)
}
LogStorageType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
""
SYNTAX StorageType
tmnxLogObjs OBJECT IDENTIFIER ::= { tmnxSRObjs 12 }
tmnxLogNotificationObjects OBJECT IDENTIFIER ::= { tmnxLogObjs 1 }
tmnxLogFileDeletedLogId OBJECT-TYPE
SYNTAX TmnxLogIdIndex
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogFileDeletedLogId indicates with which event log-id
or accounting-policy-id the deleted file was associated. Note the
corresponding entry in the tmnxLogIdTable or tmnxLogApTable may no
longer exist."
::= { tmnxLogNotificationObjects 1 }
tmnxLogFileDeletedFileId OBJECT-TYPE
SYNTAX TmnxLogFileId
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogFileDeletedFileId indicates with which event
log-id or accounting-policy-id the deleted file was associated. Note
that the corresponding entry in the tmnxLogFileIdTable may no longer
exist."
::= { tmnxLogNotificationObjects 2 }
tmnxLogFileDeletedLogType OBJECT-TYPE
SYNTAX TmnxLogFileType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogFileDeletedLogType indicates whether the deleted
file was an 'eventLog' or 'accountingPolicy'."
::= { tmnxLogNotificationObjects 3 }
tmnxLogFileDeletedLocation OBJECT-TYPE
SYNTAX TmnxCFlash
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogFileDeletedLocation indicates on which compact
flash device the event log or accounting policy file that has been
deleted was located. "
::= { tmnxLogNotificationObjects 4 }
tmnxLogFileDeletedName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogFileDeletedName indicates the pathname of an event
log or accounting policy file that has been deleted because of space
contention on a compact flash device."
::= { tmnxLogNotificationObjects 5 }
tmnxLogFileDeletedCreateTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogFileDeletedCreateTime indicates the date and time
when the deleted file had been created."
::= { tmnxLogNotificationObjects 6 }
tmnxLogTraceErrorTitle OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogTraceErrorTitle indicates the title string of the
trace error event that generated the tmnxLogTraceError notification."
::= { tmnxLogNotificationObjects 7 }
tmnxLogTraceErrorSubject OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogTraceErrorSubject indicates the subject string of
the trace error event that generated the tmnxLogTraceError
notification.
The subject is the entity that originated the event, such as the Slot
ID."
::= { tmnxLogNotificationObjects 8 }
tmnxLogTraceErrorMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogTraceErrorMessage indicates the message text
string of the trace error event that generated the tmnxLogTraceError
notification."
::= { tmnxLogNotificationObjects 9 }
tmnxLogThrottledEventID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"tmnxLogThrottledEventID is used by the tmnxLogEventThrottled
notification to indicate the NOTIFICATION-TYPE object identifier of
the throttled event."
::= { tmnxLogNotificationObjects 10 }
tmnxLogThrottledEvents OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"tmnxLogThrottledEvents is used by the tmnxLogEventThrottled
notification to indicate the number of events dropped because of event
throttling during the last throttle interval."
::= { tmnxLogNotificationObjects 11 }
tmnxSysLogTargetId OBJECT-TYPE
SYNTAX TmnxSyslogId
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"tmnxSysLogTargetId is used by the tmnxSysLogTargetProblem notification
to indicate the involved TmnxSyslogId."
::= { tmnxLogNotificationObjects 12 }
tmnxSysLogTargetProblemDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxSysLogTargetProblemDescr indicates the type of error
encountered when trying to deliver events to the destination specified
in the TmnxSyslogId."
::= { tmnxLogNotificationObjects 13 }
tmnxLogNotifyApInterval OBJECT-TYPE
SYNTAX Integer32 (5..120)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogNotifyApInterval indicates how frequently the
statistics are collected and written to their destination."
::= { tmnxLogNotificationObjects 14 }
tmnxStdReplayStartEvent OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxStdReplayStartEvent indicates the SNMP notification
request ID of the first missed event that was replayed when an SNMP
notification target address was readded to the RTM following a period
when the target address had been removed. It is used by the
tmnxStdEventsReplayed notification."
::= { tmnxLogNotificationObjects 15 }
tmnxStdReplayEndEvent OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxStdReplayEndEvent indicates the SNMP notification
request ID of the last missed event that was replayed when an SNMP
notification target address was readded to the RTM following a period
when the target address had been removed. It is used by the
tmnxStdEventsReplayed notification."
::= { tmnxLogNotificationObjects 16 }
tmnxEhsHEntryMinDelayInterval OBJECT-TYPE
SYNTAX Unsigned32 (1..604800)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryMinDelayInterval indicates the difference
between the current time and the time as mentioned in
tmnxEhsHEntryLastExecuted."
::= { tmnxLogNotificationObjects 17 }
tmnxLogMaxLogs OBJECT-TYPE
SYNTAX Unsigned32
UNITS "logs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of concurrent active Logs that are allowed. A value
of zero (0) for this object implies that there is no limit for the
number of concurrent active logs in effect.
The maximum number of logs in the Base context is restricted to 30 and
in the VPRN context to 30."
DEFVAL { 60 }
::= { tmnxLogObjs 2 }
tmnxLogFileIdTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogFileIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the Nokia SROS series Log File ID Table for providing, via
SNMP, the capability of defining the characteristics for log and
accounting files and associating them with a file-id. The actual file
is not created until the file-id is used in a log or accounting file
configuration."
::= { tmnxLogObjs 3 }
tmnxLogFileIdEntry OBJECT-TYPE
SYNTAX TmnxLogFileIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the tmnxLogFileIdTable. Entries are created
and deleted in this table by SNMP sets to tmnxLogFileIdRowStatus."
INDEX { tmnxLogFileId }
::= { tmnxLogFileIdTable 1 }
TmnxLogFileIdEntry ::= SEQUENCE
{
tmnxLogFileId TmnxLogFileId,
tmnxLogFileIdRowStatus RowStatus,
tmnxLogFileIdStorageType StorageType,
tmnxLogFileIdRolloverTime Integer32,
tmnxLogFileIdRetainTime Integer32,
tmnxLogFileIdAdminLocation TmnxCFlash,
tmnxLogFileIdOperLocation TmnxCFlash,
tmnxLogFileIdDescription TItemDescription,
tmnxLogFileIdLogType TmnxLogFileType,
tmnxLogFileIdLogId Integer32,
tmnxLogFileIdPathName DisplayString,
tmnxLogFileIdCreateTime DateAndTime,
tmnxLogFileIdBackupLoc TmnxCFlash,
tmnxLogFileIdName TLNamedItemOrEmpty
}
tmnxLogFileId OBJECT-TYPE
SYNTAX TmnxLogFileId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index value tmnxLogFileId uniquely identifies a file-id to be used
when creating a log or accounting file."
::= { tmnxLogFileIdEntry 1 }
tmnxLogFileIdRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows entries to be created and deleted
in the tmnxLogFileIdTable. Deletion of an entry in this
table will not succeed if it is currently used by any log
or accounting file."
REFERENCE
"See definition of RowStatus in RFC 2579, 'Textual
Conventions for SMIv2.'"
::= { tmnxLogFileIdEntry 2 }
tmnxLogFileIdStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The storage type for this conceptual row. Conceptual rows having the
value 'permanent' need not allow write access to any columnar objects
in the row."
DEFVAL { nonVolatile }
::= { tmnxLogFileIdEntry 3 }
tmnxLogFileIdRolloverTime OBJECT-TYPE
SYNTAX Integer32 (5..10080)
UNITS "minutes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFileIdRolloverTime specifies how often, in
minutes, a new log or accounting file will be created. If the value
of tmnxLogFileIdLogType is not 'rollover', then the value of this
object is irrelevant."
DEFVAL { 1440 }
::= { tmnxLogFileIdEntry 4 }
tmnxLogFileIdRetainTime OBJECT-TYPE
SYNTAX Integer32 (1..500)
UNITS "hours"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFileIdRetainTime specifies the minimum time,
in hours, that a file is retained on the media. Once this time
period has expired the file is deleted."
DEFVAL { 12 }
::= { tmnxLogFileIdEntry 5 }
tmnxLogFileIdAdminLocation OBJECT-TYPE
SYNTAX TmnxCFlash
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFileIdAdminLocation specifies where the log
or accounting file should be created. The file location should be a
compact flash on the primary CPM. When the secondary CPM becomes
the primary CPM after a failure, the same log file policies will
be activated. Thus it is recommended that the same media is
available to both secondary and primary CPMs.
If no location is specified, 0, the compact flash cf1: is used to
store the log files or cf2: is used to store accounting files."
DEFVAL { 0 }
::= { tmnxLogFileIdEntry 6 }
tmnxLogFileIdOperLocation OBJECT-TYPE
SYNTAX TmnxCFlash
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogFileIdOperLocation indicates where the log
or accounting file has been created. The file location should be a
compact flash on the primary CPM. When the secondary CPM becomes
the primary CPM after a failure, the same log file policies will
be activated. Thus it is recommended that the same media is
available to both secondary and primary CPMs."
::= { tmnxLogFileIdEntry 7 }
tmnxLogFileIdDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFileIdDescription is a user provided description
string for this log file-id entry. It can consist of any printable,
seven-bit ASCII characters up to 80 characters in length."
DEFVAL { ''h }
::= { tmnxLogFileIdEntry 8 }
tmnxLogFileIdLogType OBJECT-TYPE
SYNTAX TmnxLogFileType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogFileIdLogType indicates the type of information
that will be written to this file."
::= { tmnxLogFileIdEntry 9 }
tmnxLogFileIdLogId OBJECT-TYPE
SYNTAX Integer32 (0..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogFileIdLogId indicates the ID index of the log or
accounting policy this file is attached to. A value of zero (0)
indicates that this file definition is not currently used by any
log or accounting policy."
::= { tmnxLogFileIdEntry 10 }
tmnxLogFileIdPathName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogFileIdPathName is the pathname of the currently
opened file used by this file-id entry. The value of
tmnxLogFileIdPathName is affected by the value of stiPreferLocalTime."
::= { tmnxLogFileIdEntry 11 }
tmnxLogFileIdCreateTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogFileIdCreateTime is the time the currently opened
file version used by this file-id entry was created. The value of
tmnxLogFileIdCreateTime is affected by the value of
stiPreferLocalTime."
::= { tmnxLogFileIdEntry 12 }
tmnxLogFileIdBackupLoc OBJECT-TYPE
SYNTAX TmnxCFlash
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFileIdBackupLoc specifies where the log
or accounting file should be created if it cannot be created in
the location specified by tmnxLogFileIdAdminLocation. The file
location should be a compact flash on the primary CPM. When the
secondary CPM becomes the primary CPM after a failure, the same
log file policies will be activated. Thus it is recommended that
the same media is available to both secondary and primary CPMs.
If no backup location is specified, 0, and the log or accounting file
could not be created in the location specified by
tmnxLogFileIdAdminLocation or the file creation at the specified
backup location fails, a file create failure trap is issued and the
associated log or accounting policy is marked as operationally
'outOfService'."
DEFVAL { 0 }
::= { tmnxLogFileIdEntry 13 }
tmnxLogFileIdName OBJECT-TYPE
SYNTAX TLNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFileIdName specifies particular entry in the
tmnxLogFileIdTable."
DEFVAL { "" }
::= { tmnxLogFileIdEntry 14 }
tmnxLogApTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogApEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Nokia SROS series Log Accounting Policy Table contains an entry
for each accounting policy that specifies the characteristics of the
accounting records associated with an accounting policy."
::= { tmnxLogObjs 4 }
tmnxLogApEntry OBJECT-TYPE
SYNTAX TmnxLogApEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the tmnxLogApTable. Entries in the
tmnxLogApTable are created and destroyed via SNMP Set
requests to tmnxLogApRowStatus."
INDEX { tmnxLogApPolicyId }
::= { tmnxLogApTable 1 }
TmnxLogApEntry ::= SEQUENCE
{
tmnxLogApPolicyId Integer32,
tmnxLogApRowStatus RowStatus,
tmnxLogApStorageType LogStorageType,
tmnxLogApAdminStatus TmnxAdminState,
tmnxLogApOperStatus TmnxOperState,
tmnxLogApInterval Integer32,
tmnxLogApDescription TItemDescription,
tmnxLogApDefault TruthValue,
tmnxLogApRecord INTEGER,
tmnxLogApToFileId TmnxLogFileId,
tmnxLogApPortType INTEGER,
tmnxLogApDefaultInterval TruthValue,
tmnxLogApDataLossCount Counter32,
tmnxLogApLastDataLossTimeStamp TimeStamp,
tmnxLogApToFileType INTEGER,
tmnxLogApIncludeSystemInfo TruthValue,
tmnxLogApAlign TruthValue
}
tmnxLogApPolicyId OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxLogApPolicyId uniquely identifies an accounting
policy to be used for creating accounting records. A specific
accounting policy can be applied to one or more service access
points (SAPs). Any changes made to an existing policy is applied
immediately to all SAPs where this policy is applied."
::= { tmnxLogApEntry 1 }
tmnxLogApRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows entries to be created and deleted
in the tmnxLogApTable. Deletion of an entry in this
table will not succeed if it is currently applied to any
service access point (SAP)."
REFERENCE
"See definition of RowStatus in RFC 2579, 'Textual
Conventions for SMIv2.'"
::= { tmnxLogApEntry 2 }
tmnxLogApStorageType OBJECT-TYPE
SYNTAX LogStorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The storage type for this conceptual row. Conceptual rows having the
value 'permanent' need not allow write access to any columnar objects
in the row."
DEFVAL { nonVolatile }
::= { tmnxLogApEntry 3 }
tmnxLogApAdminStatus OBJECT-TYPE
SYNTAX TmnxAdminState
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogApAdminStatus specifies the desired administrative
state for this accounting policy."
DEFVAL { outOfService }
::= { tmnxLogApEntry 4 }
tmnxLogApOperStatus OBJECT-TYPE
SYNTAX TmnxOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogApOperStatus indicates the current operational
status of this accounting policy."
::= { tmnxLogApEntry 5 }
tmnxLogApInterval OBJECT-TYPE
SYNTAX Integer32 (1..120)
UNITS "minutes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogApInterval determines how frequently the
statistics are collected and written to their destination.
If no record is specified, default value for tmnxLogApInterval is 5
minutes. For service and network types of record, default values are 5
minutes and 15 minutes respectively.
For an accounting policy with one of the following record type
(i.e. tmnxLogApRecord) values, the minimum interval is one minute:
completeOamPm(56),
completeSvcActivTestHead(76),
saa(32).
Otherwise the minimum interval is five minutes."
DEFVAL { 5 }
::= { tmnxLogApEntry 6 }
tmnxLogApDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogApDescription is a user provided description
string for this accounting policy. It can consist of any printable,
seven-bit ASCII characters up to 80 characters in length."
DEFVAL { ''h }
::= { tmnxLogApEntry 7 }
tmnxLogApDefault OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When tmnxLogApDefault has a value of 'true', it specifies that
this accounting policy is applied to all service access points (SAPs)
that do not have an explicit accounting policy applied. If no
accounting policy is associated with a SAP accounting records are
produced in accordance with the default policy.
Only one accounting policy entry in the tmnxLogApTable can have
tmnxLogApDefault set to 'true'. If there is no entry in the
tmnxLogApTable with tmnxLogApDefault set to 'true', then the
only accounting records collected are those explicitly configured
accounting policies."
DEFVAL { false }
::= { tmnxLogApEntry 8 }
tmnxLogApRecord OBJECT-TYPE
SYNTAX INTEGER {
none (0),
svcIngressOctet (1),
svcEgressOctet (2),
svcIngressPkt (3),
svcEgressPkt (4),
netIngressOctet (5),
netEgressOctet (6),
netIngressPkt (7),
netEgressPkt (8),
compactSvcInOctet (9),
combinedSvcIngress (10),
combinedNetInEgOctet (11),
combinedSvcInEgOctet (12),
completeSvcInEg (13),
combinedSvcSdpInEg (14),
completeSvcSdpInEg (15),
completeSubscrIngrEgr (16),
bsxProtocol (17),
bsxApplication (18),
bsxAppGroup (19),
bsxSubscriberProtocol (20),
bsxSubscriberApplication (21),
bsxSubscriberAppGroup (22),
customRecordSubscriber (23),
customRecordService (24),
customRecordAa (25),
queueGroupOctets (26),
queueGroupPackets (27),
combinedQueueGroup (28),
combinedMplsLspIngress (29),
combinedMplsLspEgress (30),
combinedLdpLspEgress (31),
saa (32),
video (33),
kpiSystem (34),
kpiBearerMgmt (35),
kpiBearerTraffic (36),
kpiRefPoint (37),
kpiPathMgmt (38),
kciIom3 (39),
kciSystem (40),
kciBearerMgmt (41),
kciPathMgmt (42),
completeKpi (43),
completeKci (44),
kpiBearerGroup (45),
kpiRefPathGroup (46),
kpiKciBearerMgmt (47),
kpiKciPathMgmt (48),
kpiKciSystem (49),
completeKpiKci (50),
aaPerformance (51),
completeEthernetPort (52),
extendedSvcIngrEgr (53),
completeNetIngrEgr (54),
aaPartition (55),
completeOamPm (56),
kpiRefPtSecErrorCauseCode (57),
kpiBearerTrafficGtpEndpoint (58),
kpiIpReas (59),
kpiRadiusGroup (60),
kpiRefPtFailureCauseCode (61),
kpiDhcpGroup (62),
aaAdmitDeny (63),
netIntfIngressOctet (65),
netIntfEgressOctet (66),
netIntfIngressPkt (67),
netIntfEgressPkt (68),
combinedNetIntfIngress (69),
combinedNetIntfEgress (70),
completeNetIntfIngrEgr (71),
accessEgressOctets (72),
accessEgressPackets (73),
combinedAccessEgress (74),
combinedNetworkEgress (75),
completeSvcActivTestHead (76),
combinedMplsSrteEgress (77)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogApRecord specifies the type of predefined
accounting record type to be written to the accounting file.
The value 'bsxSubscriberAppGroup (22)' was made obsolete in release
7.0 and replaced by 'customRecordAa (25).'"
DEFVAL { none }
::= { tmnxLogApEntry 9 }
tmnxLogApToFileId OBJECT-TYPE
SYNTAX TmnxLogFileId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogApToFileId is the index to the entry in the
tmnxLogFileIdTable that specifies the file characteristics to be
used for the destination of the accounting policy records collected
by this accounting policy. The file itself is created the first
time this accounting policy is applied to a service access point
(SAP).
tmnxLogApToFileId must be set along with tmnxLogApToFileType to
indicate whether the records will be stored in a file or not.
When a destination file is specified, the value of the file is
specified by tmnxLogApToFileId and the value of tmnxLogApToFileType
should be 'fileId'.
When the destination file is not specified, the value of
tmnxLogApToFileId should be zero and the value of tmnxLogApToFileType
should be 'noFile'."
::= { tmnxLogApEntry 10 }
tmnxLogApPortType OBJECT-TYPE
SYNTAX INTEGER {
none (0),
access (1),
network (2),
sdp (3),
subscriber (4),
appAssure (5),
qgrp (6),
saa (7),
mplsLspIngr (8),
mplsLspEgr (9),
ldpLspEgr (10),
video (11),
mobileGateway (12),
ethernet (13),
oamPm (14),
networkIntf (16),
accessPort (17),
svcActvTest (18),
mplsSrteEgr (19)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogApPortType indicates the type of facility
associated with the specified accounting policy's record type (i.e.
tmnxLogApRecord)."
::= { tmnxLogApEntry 11 }
tmnxLogApDefaultInterval OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"When tmnxLogApDefaultInterval has a value of 'true', it specifies that
tmnxLogApInterval will have a default value.
When tmnxLogApDefaultInterval has a value of 'false', user can set the
value of tmnxLogApInterval manually."
DEFVAL { true }
::= { tmnxLogApEntry 12 }
tmnxLogApDataLossCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogApDataLossCount indicates the number of times a
tmnxLogAccountingDataLoss trap was raised against this application
policy."
::= { tmnxLogApEntry 13 }
tmnxLogApLastDataLossTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogApLastDataLossTimeStamp indicates the last time,
since system startup that a tmnxLogAccountingDataLoss trap was raised
against this application policy."
::= { tmnxLogApEntry 14 }
tmnxLogApToFileType OBJECT-TYPE
SYNTAX INTEGER {
fileId (0),
noFile (1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogApToFileType specifies where records of an
accounting policy are stored. It should be set along with
tmnxLogApToFileId which specifies the destination file index where the
accounting records are stored.
When the value of tmnxLogApToFileType is 'noFile', it indicates that
the accounting records will not to be stored in a file and the value
of tmnxLogApToFileId should be set to zero.
When the value of tmnxLogApToFileType is 'fileId', it indicates that
the accounting records will be stored in a file specified by
tmnxLogApToFileId.
tmnxLogApOperStatus will transition to 'inService' when the
tmnxLogApToFileType is set to 'noFile' or 'fileId'."
DEFVAL { fileId }
::= { tmnxLogApEntry 15 }
tmnxLogApIncludeSystemInfo OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogApIncludeSystemInfo specifies whether or not to
include system information at the top of each accounting file
generated for a given accounting policy."
DEFVAL { false }
::= { tmnxLogApEntry 16 }
tmnxLogApAlign OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If true generation of accounting statistics is aligned with absolute
time. First statistics are generated when absolute time is dividable
by collection-interval value. After that it continues with
collection-interval. This is important for synchronization of
statistics interval between various nodes in network. If false,
generation of accounting statistis is triggered right after command
execution and continues after configured collection-interval. type
that do not have an accounting policy."
DEFVAL { false }
::= { tmnxLogApEntry 17 }
tmnxLogIdTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Nokia SROS series Log Identification Table contains an entry for
each log that specifies the characteristics of that log associated
with a log-id number."
::= { tmnxLogObjs 5 }
tmnxLogIdEntry OBJECT-TYPE
SYNTAX TmnxLogIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the tmnxLogIdTable. Entries in the
tmnxLogIdTable are created and destroyed via SNMP Set
requests to tmnxLogIdRowStatus. Default log entries 99,
and 100 are created by the agent."
INDEX { tmnxLogIdIndex }
::= { tmnxLogIdTable 1 }
TmnxLogIdEntry ::= SEQUENCE
{
tmnxLogIdIndex TmnxLogIdIndex,
tmnxLogIdRowStatus RowStatus,
tmnxLogIdStorageType LogStorageType,
tmnxLogIdAdminStatus TmnxAdminState,
tmnxLogIdOperStatus TmnxOperState,
tmnxLogIdDescription TItemDescription,
tmnxLogIdFilterId TmnxLogFilterId,
tmnxLogIdSource BITS,
tmnxLogIdDestination INTEGER,
tmnxLogIdFileId TmnxLogFileId,
tmnxLogIdSyslogId TmnxSyslogIdOrEmpty,
tmnxLogIdMaxMemorySize Unsigned32,
tmnxLogIdConsoleSession TruthValue,
tmnxLogIdForwarded Counter64,
tmnxLogIdDropped Counter64,
tmnxLogIdTimeFormat INTEGER,
tmnxLogIdPythonPolicy TNamedItemOrEmpty,
tmnxLogIdOperDestination INTEGER,
tmnxLogIdNetconfStream TNamedItemOrEmpty,
tmnxLogIdName TLNamedItemOrEmpty
}
tmnxLogIdIndex OBJECT-TYPE
SYNTAX TmnxLogIdIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxLogIdIndex uniquely identifies an event stream log."
::= { tmnxLogIdEntry 1 }
tmnxLogIdRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows entries to be created and deleted
in the tmnxLogIdTable. Deletion of an entry in this
table will not succeed if tmnxLogIdOperStatus is not
'outOfService'. tmnxLogIdOperStatus will not transition
to 'inService' if tmnxLogIdSource and tmnxLogIdDestination
and their associated objects have not been set to valid values."
REFERENCE
"See definition of RowStatus in RFC 2579, 'Textual
Conventions for SMIv2.'"
::= { tmnxLogIdEntry 2 }
tmnxLogIdStorageType OBJECT-TYPE
SYNTAX LogStorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The storage type for this conceptual row. Conceptual rows having the
value 'permanent' need not allow write access to any columnar objects
in the row."
DEFVAL { nonVolatile }
::= { tmnxLogIdEntry 3 }
tmnxLogIdAdminStatus OBJECT-TYPE
SYNTAX TmnxAdminState
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdAdminStatus specifies the desired administrative
state for this log."
DEFVAL { inService }
::= { tmnxLogIdEntry 4 }
tmnxLogIdOperStatus OBJECT-TYPE
SYNTAX TmnxOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogIdOperStatus indicates the current operational
status of this log."
::= { tmnxLogIdEntry 5 }
tmnxLogIdDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdDescription is a user provided description
string for this log. It can consist of any printable,
seven-bit ASCII characters up to 80 characters in length."
DEFVAL { ''h }
::= { tmnxLogIdEntry 6 }
tmnxLogIdFilterId OBJECT-TYPE
SYNTAX TmnxLogFilterId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdFilterId is the index into the
tmnxLogFilterTable to the entry the defines a filter to be
applied to this log's source event stream to limit the events
output to this log's destination. If tmnxLogIdFilterId has a
value of 0, then all events in the source log are forwarded
to the destination."
DEFVAL { 0 }
::= { tmnxLogIdEntry 7 }
tmnxLogIdSource OBJECT-TYPE
SYNTAX BITS {
main (0),
security (1),
change (2),
debugTrace (3),
li (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdSource is a bit mask that specifies the
log event source stream(s) to be forwarded to the destination
specified in tmnxLogIdDestination. Events from more than one
source may be forwarded to the log destination.
The 'main' event stream consists of all events that are not explicitly
directed to any other event stream.
The 'security' event stream contains all events that affect attempts
to breach system security such as failed login attempts, attempts to
access SNMP MIB tables to which the user has not been granted access,
or attempts to enter a branch of the CLI for which the user is not
authorized.
The 'user' activity event stream contains all events that directly
affect the configuration or operation of the system.
The 'debugTrace' event stream contains all events configured for
application or protocol tracing.
The 'li' event stream contains all events configured for Lawful
Intercept activities. An attempt to set the 'li' event stream
will fail with an inconsistentValue error if the requestor does
not have access to the 'li' context. An attempt to set the 'li'
event stream will fail with an inconsistentValue error if
tmnxLogIdDestination has the value 'syslog' or 'file'."
DEFVAL { {} }
::= { tmnxLogIdEntry 8 }
tmnxLogIdDestination OBJECT-TYPE
SYNTAX INTEGER {
none (0),
console (1),
syslog (2),
snmpTraps (3),
file (4),
memory (5),
netconf (7),
subscribedCli (8)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdDestination specifies the event log stream
destination. Once this object has been set to a value other than
the default 'none' it cannot be modified and attempts to reset
it to another value will fail with an INCONSISTENT VALUE error.
The 'console' destination causes all selected log events to be
directed to the system console. If the console is not connected
then all entries are dropped.
The 'syslog' destination sends all selected log events to the
syslog address configured in tmnxSyslogTargetAddress and
tmnxSyslogTargetUdpPort in the tmnxSyslogTargetTable row entry
pointed to by the value of tmnxLogIdSyslogId. An attempt to
set this object to 'syslog' will fail with an inconsistentValue
error if tmnxLogIdSource has the value 'li' set.
The 'snmpTraps' destination causes events defined as SNMP traps
to be sent to the configured SNMP trap destinations and also to
be logged in the NOTIFICATION-LOG-MIB tables. The allocated memory
size for the log of transmitted traps is specified in
tmnxLogIdMaxMemorySize. The events are logged to memory in a circular
fashion. Once the space is full, the oldest entry is replaced with
a new entry.
The 'file' destination causes all selected log events to be
directed to a file on one of the CPM's compact flash discs.
Details of the file's configuration are in the tmnxLogFileIdTable
entry pointed to by the value of tmnxLogIdFileId. An attempt to
set this object to 'file' will fail with an inconsistentValue
error if tmnxLogIdSource has the value 'li' set.
The 'memory' destination causes all selected log events to be
directed to an in memory storage area. The allocated memory size
for the log is specified in tmnxLogIdMaxMemorySize. The events are
logged to memory in a circular fashion. Once the space is full,
the oldest entry is replaced with a new entry."
DEFVAL { none }
::= { tmnxLogIdEntry 9 }
tmnxLogIdFileId OBJECT-TYPE
SYNTAX TmnxLogFileId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdFileId is the index to the entry in the
tmnxLogFileIdTable that specifies the file characteristics to be used
for the destination of the log events written to this log.
tmnxLogIdOperStatus will not transition to 'inService' until a
valid value has been set for tmnxLogIdFileId. This object is
valid only if tmnxLogIdDestination is set to 'file'.
This object can be set only once together with tmnxLogIdDestination
value of 'file'. "
::= { tmnxLogIdEntry 10 }
tmnxLogIdSyslogId OBJECT-TYPE
SYNTAX TmnxSyslogIdOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdSyslogId is the index into the
tmnxSyslogTargetTable for the row entry with the information to format
event messages to be sent to a specific syslog collector target.
This object is valid only when tmnxLogIdDestination has a value of
'syslog'. If this object has a value of zero (0), then no collector
is specified and no messages are sent.
This object can be set only once together with tmnxLogIdDestination
value of 'syslog'."
DEFVAL { 0 }
::= { tmnxLogIdEntry 11 }
tmnxLogIdMaxMemorySize OBJECT-TYPE
SYNTAX Unsigned32 (0 | 50..3000)
UNITS "events"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdMaxMemorySize specifies the amount of memory to
allocate for this log. This object can be set only once together with
tmnxLogIdDestination has a value of 'memory', 'netconf', 'snmpTraps' or 'subscribedCli'.
For any other value of tmnxLogIdDestination, a read of this object will return zero (0).
Once a memory size has been specified and the log created, any attempt
to modify this object will fail with an INCONSISTENT VALUE error."
DEFVAL { 100 }
::= { tmnxLogIdEntry 12 }
tmnxLogIdConsoleSession OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"This object exists for the convenience of the Nokia SROS CLI.
When set to 'true' it indicates that the 'CONSOLE' log output
should be printed to the Telnet session instead of the CONSOLE
device. When a tmnxLogIdEntry is created directly via SNMP,
setting this object has no meaning and the 'CONSOLE' log output
will always be sent to the CONSOLE device. This object is obsoleted
in 15.0 Release."
DEFVAL { false }
::= { tmnxLogIdEntry 13 }
tmnxLogIdForwarded OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogIdForwarded is the count of the number of events
that have been forwarded to this log's destination. This counter is
incremented after an event has been selected by the log filter defined
in tmnxLogIdFilterId."
::= { tmnxLogIdEntry 14 }
tmnxLogIdDropped OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogIdDropped is the count of the number of events
that have been sent to this logs source(s) and that have not been
forwarded to the log destination because they were filtered out by the
log filter defined in tmnxLogIdFilterId."
::= { tmnxLogIdEntry 15 }
tmnxLogIdTimeFormat OBJECT-TYPE
SYNTAX INTEGER {
utc (1),
local (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdTimeFormat specifies the type of timestamp
format for events sent to logs where tmnxLogIdDestination has a value
of either 'syslog (2)' or 'file (4)'.
When tmnxLogIdTimeFormat has a value of 'utc (1)' timestamps are
written using the Coordinated Universal Time value. When
tmnxLogIdTimeFormat has a value of 'local (2)' timestamps are
written in the system's local time."
DEFVAL { utc }
::= { tmnxLogIdEntry 16 }
tmnxLogIdPythonPolicy OBJECT-TYPE
SYNTAX TNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdPythonPolicy specifies the name of a Python
policy.
The name refers to a conceptual row in the
TIMETRA-PYTHON-MIB::tmnxPythonPolicyTable. The Python policy should
have Python scripts to modify the log message text.
While the value of tmnxLogIdAdminStatus is equal to 'inService', a
non-empty value for this object is only allowed if the value of
tmnxLogIdDestination is equal to 'syslog'."
DEFVAL { ''h }
::= { tmnxLogIdEntry 17 }
tmnxLogIdOperDestination OBJECT-TYPE
SYNTAX INTEGER {
none (0),
console (1),
syslog (2),
snmpTraps (3),
file (4),
memory (5),
cliSession (6),
netconf (7),
subscribedCli (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogIdOperDestination indicates the operational value
of event log stream destination.
The 'console' destination indicates all selected log events will be
directed to the system console.
The 'syslog' destination indicates all selected log events will be
directed to the syslog address configured in tmnxSyslogTargetAddress
and tmnxSyslogTargetUdpPort in the tmnxSyslogTargetTable row entry
pointed to by the value of tmnxLogIdSyslogId.
The 'snmpTraps' destination indicates events defined as SNMP traps
will be sent to the configured SNMP trap destinations and also to be
logged in the NOTIFICATION-LOG-MIB tables.
The 'file' destination indicates all selected log events will be
directed to a file on one of the CPM's compact flash discs.
The 'memory' destination indicates all selected log events will be
directed to an in memory storage area.
The 'cliSession' destination indicates all selected log events will be
directed to a cli session. tmnxLogIdDestination will have a value
'none' in this case."
DEFVAL { none }
::= { tmnxLogIdEntry 18 }
tmnxLogIdNetconfStream OBJECT-TYPE
SYNTAX TNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdNetconfStream specifies the name of the NETCONF
stream associated with this log.
A non-empty value for this object is only allowed if the value of
tmnxLogIdDestination is equal to 'netconf'."
DEFVAL { "" }
::= { tmnxLogIdEntry 19 }
tmnxLogIdName OBJECT-TYPE
SYNTAX TLNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogIdName specifies an event stream log."
DEFVAL { "" }
::= { tmnxLogIdEntry 20 }
tmnxLogFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" "
::= { tmnxLogObjs 6 }
tmnxLogFilterEntry OBJECT-TYPE
SYNTAX TmnxLogFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular Log Filter entry.
Entries are created by user. Entries are deleted by user. Entry 1001
is created by the agent for default TmnxLogIdIndex 100.
There is no StorageType object. Entries have a presumed
StorageType of nonVolatile."
INDEX { tmnxLogFilterId }
::= { tmnxLogFilterTable 1 }
TmnxLogFilterEntry ::= SEQUENCE
{
tmnxLogFilterId TmnxLogFilterId,
tmnxLogFilterRowStatus RowStatus,
tmnxLogFilterDescription TItemDescription,
tmnxLogFilterDefaultAction TFilterAction,
tmnxLogFilterInUse TruthValue,
tmnxLogFilterName TLNamedItemOrEmpty
}
tmnxLogFilterId OBJECT-TYPE
SYNTAX TmnxLogFilterId (1..1500)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxLogFilterId is a unique index that identifies a
particular entry in the tmnxLogFilterTable."
::= { tmnxLogFilterEntry 1 }
tmnxLogFilterRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row entries in this table are created and destroyed via SNMP set
requests."
::= { tmnxLogFilterEntry 2 }
tmnxLogFilterDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterDescription is a user provided description
string for this log filter. It can consist of any printable,
seven-bit ASCII characters up to 80 characters in length."
DEFVAL { ''H }
::= { tmnxLogFilterEntry 3 }
tmnxLogFilterDefaultAction OBJECT-TYPE
SYNTAX TFilterAction
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The action to take for packets that do not match any filter entries.
the values default(3), and nat(5) are not allowed."
DEFVAL { forward }
::= { tmnxLogFilterEntry 4 }
tmnxLogFilterInUse OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When tmnxLogFilterInUse has a value of 'true', this filter is
attached to a log file configuration. The same tmnxLogFilterEntry
can be attached to more than one log file."
::= { tmnxLogFilterEntry 5 }
tmnxLogFilterName OBJECT-TYPE
SYNTAX TLNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterName specifies particular entry in the
tmnxLogFilterTable."
DEFVAL { "" }
::= { tmnxLogFilterEntry 6 }
tmnxLogFilterParamsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogFilterParamsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of all log filter match entries for all log filters."
::= { tmnxLogObjs 7 }
tmnxLogFilterParamsEntry OBJECT-TYPE
SYNTAX TmnxLogFilterParamsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular Log Filter Parameter entry. Every Log
Filter can have zero or more Log Filter Parameter match entries.
The Log Filter parameter entries are checked in ascending order by
their index value, tmnxLogFilterParamsIndex. Upon the first successful
match, the specified actions are applied as indicated by the value of
tmnxLogFilterParamsAction. No further checking against
remaining tmnxLogFilterParamsEntry rows is done. Therefore, entries
in this table should be sequenced from most to least explicit match
criterion. It is recommended that multiple parameter entries for a log
filter should be created with gaps between their index values. This
allows a new entry to be inserted into an existing filter policy
without needing to renumber the already existing filter parameters
entries.
A log filter entry in the tmnxLogFilterTable with no entry in the
tmnxLogFilterParamsTable to define its match criteria set will match
every log event, and the default action specified by
tmnxLogFilterDefaultAction will be taken.
Entries are created by user. Entries are deleted by user.
There is no StorageType object, entries have a presumed StorageType of
nonVolatile."
INDEX {
tmnxLogFilterId,
tmnxLogFilterParamsIndex
}
::= { tmnxLogFilterParamsTable 1 }
TmnxLogFilterParamsEntry ::= SEQUENCE
{
tmnxLogFilterParamsIndex TmnxLogFilterEntryId,
tmnxLogFilterParamsRowStatus RowStatus,
tmnxLogFilterParamsDescription TItemDescription,
tmnxLogFilterParamsAction TFilterActionOrDefault,
tmnxLogFilterParamsApplication TNamedItemOrEmpty,
tmnxLogFilterParamsApplOperator TmnxLogFilterOperator,
tmnxLogFilterParamsNumber TmnxEventNumber,
tmnxLogFilterParamsNumberOperator TmnxLogFilterOperator,
tmnxLogFilterParamsSeverity TmnxPerceivedSeverity,
tmnxLogFilterParamsSeverityOperator TmnxLogFilterOperator,
tmnxLogFilterParamsSubject TNamedItemOrEmpty,
tmnxLogFilterParamsSubjectOperator TmnxLogFilterOperator,
tmnxLogFilterParamsSubjectRegexp TruthValue,
tmnxLogFilterParamsRouter TNamedItemOrEmpty,
tmnxLogFilterParamsRouterOperator TmnxLogFilterOperator,
tmnxLogFilterParamsRouterRegexp TruthValue,
tmnxLogFilterParamsMsg OCTET STRING,
tmnxLogFilterParamsMsgOperator TmnxLogFilterOperator,
tmnxLogFilterParamsMsgRegexp TruthValue,
tmnxLogFilterParamsName TLNamedItemOrEmpty
}
tmnxLogFilterParamsIndex OBJECT-TYPE
SYNTAX TmnxLogFilterEntryId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { tmnxLogFilterParamsEntry 1 }
tmnxLogFilterParamsRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row Status for this Log filter's parameter entry."
::= { tmnxLogFilterParamsEntry 2 }
tmnxLogFilterParamsDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsDescription is a user provided
description string for this log filter match entry. It can consist
of any printable, seven-bit ASCII characters up to 80 characters in
length."
DEFVAL { ''H }
::= { tmnxLogFilterParamsEntry 3 }
tmnxLogFilterParamsAction OBJECT-TYPE
SYNTAX TFilterActionOrDefault
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"the action to take for log events that match this filter entry.
the value default(3) is allowed. If tmnxLogFilterParamsAction
has the value 'default', the action specified by the value
of tmnxLogFilterDefaultAction is applied to events that match
this filter entry. The value nat(5) is not allowed."
DEFVAL { default }
::= { tmnxLogFilterParamsEntry 4 }
tmnxLogFilterParamsApplication OBJECT-TYPE
SYNTAX TNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Matches log events with the specified application name. An
application is the software entity the reports the log event and
includes IP, MPLS, OSPF, CLI, SERVICES, etc."
DEFVAL { ''H }
::= { tmnxLogFilterParamsEntry 5 }
tmnxLogFilterParamsApplOperator OBJECT-TYPE
SYNTAX TmnxLogFilterOperator
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsApplOperator is the comparison
operator to use to determine if the log event matches the value
of tmnxLogFilterParamsApplication. The only valid values from
TmnxLogFilterOperator are 'off', 'equal', and 'notEqual'."
DEFVAL { off }
::= { tmnxLogFilterParamsEntry 6 }
tmnxLogFilterParamsNumber OBJECT-TYPE
SYNTAX TmnxEventNumber
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsNumber is the log event number to
be matched. Event numbers uniquely identify a certain event within
an application but not across applications."
DEFVAL { 0 }
::= { tmnxLogFilterParamsEntry 7 }
tmnxLogFilterParamsNumberOperator OBJECT-TYPE
SYNTAX TmnxLogFilterOperator
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsNumberOperator is the comparison
operator to use to determine if the log event matches the value of
tmnxLogFilterParamsNumber."
DEFVAL { off }
::= { tmnxLogFilterParamsEntry 8 }
tmnxLogFilterParamsSeverity OBJECT-TYPE
SYNTAX TmnxPerceivedSeverity
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsSeverity is the log event severity
level to be matched."
DEFVAL { none }
::= { tmnxLogFilterParamsEntry 9 }
tmnxLogFilterParamsSeverityOperator OBJECT-TYPE
SYNTAX TmnxLogFilterOperator
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsSeverityOperator is the comparison
operator to use to determine if the log event matches the value of
tmnxLogFilterParamsSeverity."
DEFVAL { off }
::= { tmnxLogFilterParamsEntry 10 }
tmnxLogFilterParamsSubject OBJECT-TYPE
SYNTAX TNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsSubject is the log event subject
string to be matched. The subject is the entity that the event is
reported for, such as a port ID."
DEFVAL { ''H }
::= { tmnxLogFilterParamsEntry 11 }
tmnxLogFilterParamsSubjectOperator OBJECT-TYPE
SYNTAX TmnxLogFilterOperator
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsSubjectOperator is the comparison
operator to use to determine if the log event matches the value
of tmnxLogFilterParamsSubject. The only valid values of
TmnxLogFilterOperator to use for the subject string comparison are
'off', 'equal', and 'notEqual'."
DEFVAL { off }
::= { tmnxLogFilterParamsEntry 12 }
tmnxLogFilterParamsSubjectRegexp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsSubjectRegexp specifies the type
of string comparison to use to determine if the log event matches
the value of tmnxLogFilterParamsSubject. When the value of
tmnxLogFilterParamsSubjectRegexp is 'true', the string in
tmnxLogFilterParamsSubject is a regular expression string to be
matched against the subject string in the log event being filtered.
When it has a value of 'false', the string in
tmnxLogFilterParamsSubject is matched exactly by the event
filter."
DEFVAL { false }
::= { tmnxLogFilterParamsEntry 13 }
tmnxLogFilterParamsRouter OBJECT-TYPE
SYNTAX TNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsRouter is the log event router context
name string to be matched."
DEFVAL { ''H }
::= { tmnxLogFilterParamsEntry 14 }
tmnxLogFilterParamsRouterOperator OBJECT-TYPE
SYNTAX TmnxLogFilterOperator
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsRouterOperator is the comparison
operator to use to determine if the log event matches the value
of tmnxLogFilterParamsRouter. The only valid values of
TmnxLogFilterOperator to use for the router name string comparison
are 'off', 'equal', and 'notEqual'."
DEFVAL { off }
::= { tmnxLogFilterParamsEntry 15 }
tmnxLogFilterParamsRouterRegexp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsRouterRegexp specifies the type
of string comparison to use to determine if the log event matches
the value of tmnxLogFilterParamsRouter. When the value of
tmnxLogFilterParamsRouterRegexp is 'true', the string in
tmnxLogFilterParamsRouter is a regular expression string to be
matched against the router name string in the log event being
filtered. When it has a value of 'false', the string in
tmnxLogFilterParamsRouter is matched exactly by the event
filter."
DEFVAL { false }
::= { tmnxLogFilterParamsEntry 16 }
tmnxLogFilterParamsMsg OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0|1..400))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsMsg specifies the log event message
string to be matched. Matching result is determined based on value of
tmnxLogFilterParamsMsgOperator. Matching type is determined based on
value of tmnxLogFilterParamsMsgRegexp"
DEFVAL { ''H }
::= { tmnxLogFilterParamsEntry 17 }
tmnxLogFilterParamsMsgOperator OBJECT-TYPE
SYNTAX TmnxLogFilterOperator
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsMsgOperator specifies the comparison
operator used to determine if the log event matches the value
of tmnxLogFilterParamsMsg. The only valid values of tmnxLogFilterParamsMsgOperator
to use for the string comparison are 'off', 'equal', and 'notEqual'."
DEFVAL { off }
::= { tmnxLogFilterParamsEntry 18 }
tmnxLogFilterParamsMsgRegexp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsMsgRegexp specifies the type
of string comparison to use to determine if the log event matches
the value of tmnxLogFilterParamsMsg. When the value of
tmnxLogFilterParamsMsgRegexp is 'true', the string in
tmnxLogFilterParamsMsg is a regular expression string to be
matched against the message string in the log event being filtered.
When it has a value of 'false', the string in
tmnxLogFilterParamsMsg is matched as substring by the event
filter."
DEFVAL { false }
::= { tmnxLogFilterParamsEntry 19 }
tmnxLogFilterParamsName OBJECT-TYPE
SYNTAX TLNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogFilterParamsName specifies particular entry in the
tmnxLogFilterParamsTable."
DEFVAL { "" }
::= { tmnxLogFilterParamsEntry 20 }
tmnxSyslogTargetTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxSyslogTargetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of all remote syslog collectors that this agent is configured
to send syslog messages to."
::= { tmnxLogObjs 8 }
tmnxSyslogTargetEntry OBJECT-TYPE
SYNTAX TmnxSyslogTargetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular Syslog Target entry.
Entries are created by user. Entries are deleted by user.
There is no StorageType object, entries have a presumed StorageType of
nonVolatile. "
INDEX { tmnxSyslogTargetIndex }
::= { tmnxSyslogTargetTable 1 }
TmnxSyslogTargetEntry ::= SEQUENCE
{
tmnxSyslogTargetIndex TmnxSyslogId,
tmnxSyslogTargetRowStatus RowStatus,
tmnxSyslogTargetDescription TItemDescription,
tmnxSyslogTargetAddress IpAddress,
tmnxSyslogTargetUdpPort TmnxUdpPort,
tmnxSyslogTargetFacility TmnxSyslogFacility,
tmnxSyslogTargetSeverity TmnxSyslogSeverity,
tmnxSyslogTargetMessagePrefix TNamedItemOrEmpty,
tmnxSyslogTargetMessagesDropped Counter32,
tmnxSyslogTargetAddrType InetAddressType,
tmnxSyslogTargetAddr InetAddress,
tmnxSyslogTargetName TLNamedItemOrEmpty,
tmnxSyslogTlsClntProfileName TNamedItemOrEmpty
}
tmnxSyslogTargetIndex OBJECT-TYPE
SYNTAX TmnxSyslogId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxSyslogTargetIndex is a unique arbitrary identifier
for this syslog collector target.
The maximum value of tmnxSyslogTargetIndex is limited to 10 for the
Base router context and to 30 for the VPRN context."
::= { tmnxSyslogTargetEntry 1 }
tmnxSyslogTargetRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The tmnxSyslogTargetRowStatus object allows for dynamic creation and
deletion of row entries in the tmnxSyslogTargetTable as well as the
activation and deactivation of these entries.
When this object's value is set to 'notInService (2)', no messages
will be sent to this target collector and none of its counters will be
incremented.
Refer to the RowStatus convention for further details on the behavior
of this object."
REFERENCE
"RFC2579 (Textual Conventions for SMIv2)"
::= { tmnxSyslogTargetEntry 2 }
tmnxSyslogTargetDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxSyslogTargetDescription is an administratively
assigned textual description of this syslog collector target."
DEFVAL { ''H }
::= { tmnxSyslogTargetEntry 3 }
tmnxSyslogTargetAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"The value of tmnxSyslogTargetAddress is the IPv4 address for
this syslog message collector target. If the value of this
object is '0.0.0.0', then no messages will be sent, nor will
any counters be incremented.
This object was made obsolete in release 5.0. It is replaced
by the InetAddress pair tmnxSyslogTargetAddrType and
tmnxSyslogTargetAddr."
DEFVAL { '00000000'h }
::= { tmnxSyslogTargetEntry 4 }
tmnxSyslogTargetUdpPort OBJECT-TYPE
SYNTAX TmnxUdpPort
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxSyslogTargetUdpPort is the UDP port number that is
used to send messages to this syslog collector target."
DEFVAL { 514 }
::= { tmnxSyslogTargetEntry 5 }
tmnxSyslogTargetFacility OBJECT-TYPE
SYNTAX TmnxSyslogFacility
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxSyslogTargetFacility is the syslog facility number
that will be encoded in messages sent to this syslog collector target."
DEFVAL { local7 }
::= { tmnxSyslogTargetEntry 6 }
tmnxSyslogTargetSeverity OBJECT-TYPE
SYNTAX TmnxSyslogSeverity
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxSyslogTargetSeverity is the maximum severity level
of the messages that SHOULD be forwarded to this syslog collector
target. The higher the level, the lower the severity."
DEFVAL { info }
::= { tmnxSyslogTargetEntry 7 }
tmnxSyslogTargetMessagePrefix OBJECT-TYPE
SYNTAX TNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxSyslogTargetMessagePrefix is a string of ABNF
alphanumeric characters to be prepended as the MSG TAG to the syslog
MSG CONTENT string and separated from it with a colon and space, ': '."
DEFVAL { "TMNX" }
::= { tmnxSyslogTargetEntry 8 }
tmnxSyslogTargetMessagesDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxSyslogTargetMessagesDropped is a count of messages
not sent to this syslog collector target because the severity level of
the message was above tmnxSyslogTargetSeverity; the higher the level,
the lower the severity."
::= { tmnxSyslogTargetEntry 9 }
tmnxSyslogTargetAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxSyslogTargetAddrType specifies the type of host
address to be used for the syslog message collector target. This
object indicates the type of address stored in the corresponding
tmnxSyslogTargetAddr object.
Only 'ipv4', 'ipv6', and 'ipv6z' address types are supported."
DEFVAL { unknown }
::= { tmnxSyslogTargetEntry 10 }
tmnxSyslogTargetAddr OBJECT-TYPE
SYNTAX InetAddress (SIZE (0|4|16|20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxSyslogTargetAddr specifies the IP host address
to be used for the syslog message collector target. If no address
is specified, ''H, then no messages will be sent nor will
any counters be incremented.
The syslog target address type is determined by the value of the
corresponding tmnxSyslogTargetAddrType object."
DEFVAL { ''H }
::= { tmnxSyslogTargetEntry 11 }
tmnxSyslogTargetName OBJECT-TYPE
SYNTAX TLNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxSyslogTargetName specifies particular entry in the
tmnxSyslogTargetTable."
DEFVAL { "" }
::= { tmnxSyslogTargetEntry 12 }
tmnxSyslogTlsClntProfileName OBJECT-TYPE
SYNTAX TNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of the object tmnxSyslogTlsClntProfileName specifies the
name for a TLS client profile. If configured, syslog uses TLS."
DEFVAL { "" }
::= { tmnxSyslogTargetEntry 13 }
tmnxEventAppTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxEventAppEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of all applications that generate TiMOS logger events."
::= { tmnxLogObjs 9 }
tmnxEventAppEntry OBJECT-TYPE
SYNTAX TmnxEventAppEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular application entry.
Entries are created by the agent when the system initializes.
There is no StorageType object, entries have a presumed StorageType of
permanent. "
INDEX { tmnxEventAppIndex }
::= { tmnxEventAppTable 1 }
TmnxEventAppEntry ::= SEQUENCE
{
tmnxEventAppIndex Unsigned32,
tmnxEventAppName TNamedItem
}
tmnxEventAppIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxEventAppIndex is a unique arbitrary identifier for
this application event generator."
::= { tmnxEventAppEntry 1 }
tmnxEventAppName OBJECT-TYPE
SYNTAX TNamedItem
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEventAppName is the name string that is used in TiMOS
log messages as the application that generated the logged event."
::= { tmnxEventAppEntry 2 }
tmnxEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of all TiMOS events that can be generated."
::= { tmnxLogObjs 10 }
tmnxEventEntry OBJECT-TYPE
SYNTAX TmnxEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular TiMOS event type entry. Entries are
created by the agent when the system initializes. There is no
StorageType object, entries have a presumed StorageType of permanent. "
INDEX {
tmnxEventAppIndex,
tmnxEventID
}
::= { tmnxEventTable 1 }
TmnxEventEntry ::= SEQUENCE
{
tmnxEventID Unsigned32,
tmnxEventName TNamedItem,
tmnxEventSeverity TmnxPerceivedSeverity,
tmnxEventControl TruthValue,
tmnxEventCounter Counter32,
tmnxEventDropCount Counter32,
tmnxEventReset TmnxActionType,
tmnxEventThrottle TruthValue,
tmnxEventSpecThrottle TruthValue,
tmnxEventSpecThrottleLimit Unsigned32,
tmnxEventSpecThrottleIntval Unsigned32,
tmnxEventSpecThrottleDef TruthValue,
tmnxEventSpecThrottleLimitDef Unsigned32,
tmnxEventSpecThrottleIntvalDef Unsigned32,
tmnxEventRepeat TruthValue
}
tmnxEventID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxEventID is a unique arbitrary identifier for indexing
event type entries within an event generator application as identified
by the value of tmnxEventAppIndex."
::= { tmnxEventEntry 1 }
tmnxEventName OBJECT-TYPE
SYNTAX TNamedItem
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEventName is a short name string used to describe
this event type."
::= { tmnxEventEntry 2 }
tmnxEventSeverity OBJECT-TYPE
SYNTAX TmnxPerceivedSeverity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxEventSeverity specifies the severity level that will
be associated with this type of event when it is generated."
::= { tmnxEventEntry 3 }
tmnxEventControl OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxEventControl determines whether or not events
of this type will be generated or suppressed. When it has a value
of 'true', the event is generated and tmnxEventCounter is incremented.
When it has a value of 'false', the event is suppressed and
tmnxEventDropCount is incremented."
::= { tmnxEventEntry 4 }
tmnxEventCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEventCounter is the number of times an event of this
type has been generated."
::= { tmnxEventEntry 5 }
tmnxEventDropCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEventDropCount is the number of times and event
of this type has been suppressed because tmnxEventControl is set to
'false'. When tmnxEventControl is set to 'true', tmnxEventDropCount
indicates the number of events dropped because of logger input
queue size overrun or dropped because of throttling when
tmnxEventThrottle is set to 'true'."
::= { tmnxEventEntry 6 }
tmnxEventReset OBJECT-TYPE
SYNTAX TmnxActionType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting tmnxEventReset to 'doAction (1)' causes the agent to reset the
values of tmnxEventSeverity and tmnxEventControl to the default values
for this event type."
DEFVAL { notApplicable }
::= { tmnxEventEntry 7 }
tmnxEventThrottle OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxEventThrottle determines whether or not events
of this type will be throttled. When it has a value
of 'true', the event is throttled at the rate indicated by the
value of tmnxEventThrottleLimit and tmnxEventThrottleInterval.
When it has a value of 'false', no event throttling is applied."
DEFVAL { false }
::= { tmnxEventEntry 8 }
tmnxEventSpecThrottle OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxEventSpecThrottle specifies if events of this type
will be throttled using the parameters specific for this event.
When the value of tmnxEventSpecThrottle is equal to 'true', the event
is throttled at the rate indicated by the value of
tmnxEventSpecThrottleLimit and tmnxEventSpecThrottleIntval.
When it has a value of 'false', no event-specific throttling is
applied.
The default value depends on the event."
::= { tmnxEventEntry 9 }
tmnxEventSpecThrottleLimit OBJECT-TYPE
SYNTAX Unsigned32 (0 | 1..20000)
UNITS "events"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxEventSpecThrottleLimit specifies the number of times
that this event can be logged within the tmnxEventSpecThrottleIntval.
Once this limit has been reached, any additional events of this type
will be dropped, i.e. tmnxEventDropCount will be incremented.
At the end of the specific throttle interval if any events have been
dropped a tmnxLogEventThrottled notification will be sent if the rate
is applied to the whole stream of log events of this type; otherwise,
if the rate is applied to each source of this type of event, the
TIMETRA-SYSTEM-MIB::tmnxTrapDropped will be sent.
The value must be zero while the value of tmnxEventSpecThrottle is
'false'.
The default value depends on the event type."
::= { tmnxEventEntry 10 }
tmnxEventSpecThrottleIntval OBJECT-TYPE
SYNTAX Unsigned32 (0 | 1..1200)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxEventSpecThrottleIntval specifies the number of
seconds that the event-specific throttling interval lasts.
The value must be zero while the value of tmnxEventSpecThrottle is
'false'.
The default value depends on the event type."
::= { tmnxEventEntry 11 }
tmnxEventSpecThrottleDef OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEventSpecThrottleDef indicates the default value of
tmnxEventSpecThrottle."
::= { tmnxEventEntry 12 }
tmnxEventSpecThrottleLimitDef OBJECT-TYPE
SYNTAX Unsigned32 (0 | 1..20000)
UNITS "events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEventSpecThrottleLimitDef indicates the default value
of the object tmnxEventSpecThrottleLimit.
The value zero indicates that there is by default no event-specific
throttling for this event."
::= { tmnxEventEntry 13 }
tmnxEventSpecThrottleIntvalDef OBJECT-TYPE
SYNTAX Unsigned32 (0 | 1..1200)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEventSpecThrottleIntvalDef indicates the default
value of tmnxEventSpecThrottleIntval.
The value zero indicates that there is by default no event-specific
throttling for this type of event."
::= { tmnxEventEntry 14 }
tmnxEventRepeat OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"repeat"
DEFVAL { false }
::= { tmnxEventEntry 15 }
tmnxSnmpTrapGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxSnmpTrapGroupEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"A table of all remote SNMP trap collectors to which this agent is
configured to send SNMP notifications messages.
This table was made obsolete in the 5.0 release and is replaced with
tmnxSnmpTrapDestTable."
::= { tmnxLogObjs 11 }
tmnxSnmpTrapGroupEntry OBJECT-TYPE
SYNTAX TmnxSnmpTrapGroupEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Information about a particular SNMP trap destination entry. The first
index instance creates and snmp trap group to be associated with the
event log with the same value for tmnxLogIdIndex. The second and third
indexes specify a remote SNMP trap destination that will be sent SNMP
notification messages from the associated event log.
Entries are created by user. Entries are deleted by user.
There is no StorageType object, entries have a presumed StorageType of
nonVolatile.
This table was made obsolete in the 5.0 release and is replaced with
the tmnxSnmpTrapDestTable."
INDEX {
tmnxStgIndex,
tmnxStgDestAddress,
tmnxStgDestPort
}
::= { tmnxSnmpTrapGroupTable 1 }
TmnxSnmpTrapGroupEntry ::= SEQUENCE
{
tmnxStgIndex TmnxStgIndex,
tmnxStgDestAddress IpAddress,
tmnxStgDestPort TmnxUdpPort,
tmnxStgRowStatus RowStatus,
tmnxStgDescription TItemDescription,
tmnxStgVersion SnmpMessageProcessingModel,
tmnxStgNotifyCommunity OCTET STRING,
tmnxStgSecurityLevel SnmpSecurityLevel
}
tmnxStgIndex OBJECT-TYPE
SYNTAX TmnxStgIndex
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"The value of tmnxStgIndex specifies an snmp trap group to be
associated with the event log with the same value for tmnxLogIdIndex.
This object was made obsolete in the 5.0 release. It is
replaced by tmnxStdIndex."
::= { tmnxSnmpTrapGroupEntry 1 }
tmnxStgDestAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"The value of tmnxStgDestAddress is the IPv4 address for
this remote snmp notification destination. If the value of this
object is '0.0.0.0', then no messages will be sent, nor will
any counters be incremented.
This object was made obsolete in the 5.0 release. It is
replaced by the InetAddressType/InetAddress objects
tmnxStdDestAddrType and tmnxStdDestAddr."
DEFVAL { '00000000'h }
::= { tmnxSnmpTrapGroupEntry 2 }
tmnxStgDestPort OBJECT-TYPE
SYNTAX TmnxUdpPort
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"The value of tmnxStgDestPort is the UDP port number that is used to
send messages to this remote SNMP notification destination.
This object was made obsolete in the 5.0 release. It is
replaced by tmnxStdDestPort."
DEFVAL { 162 }
::= { tmnxSnmpTrapGroupEntry 3 }
tmnxStgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"The tmnxStgRowStatus object allows for dynamic creation and deletion
of row entries in the tmnxSnmpTrapGroupTable as well as the activation
and deactivation of these entries.
When this object's value is set to 'notInService (2)', no messages
will be sent to this snmp trap group and none of its counters will be
incremented.
Refer to the RowStatus convention for further details on the behavior
of this object.
This object was made obsolete in the 5.0 release. It is
replaced by tmnxStdRowStatus."
REFERENCE
"RFC2579 (Textual Conventions for SMIv2)"
::= { tmnxSnmpTrapGroupEntry 4 }
tmnxStgDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"The value of tmnxStgDescription is an administratively assigned
textual description of this snmp trap destination.
This object was made obsolete in the 5.0 release. It is
replaced by tmnxStdDescription."
DEFVAL { ''H }
::= { tmnxSnmpTrapGroupEntry 5 }
tmnxStgVersion OBJECT-TYPE
SYNTAX SnmpMessageProcessingModel
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"The value of tmnxStgVersion specifies the SNMP version that will be
used to format notification messages sent to this snmp trap
destination.
The values supported by the Nokia SROS series SNMP agent are:
0 for SNMPv1
1 for SNMPv2c
3 for SNMPv3
This object was made obsolete in the 5.0 release. It is
replaced by tmnxStdVersion."
DEFVAL { 3 }
::= { tmnxSnmpTrapGroupEntry 6 }
tmnxStgNotifyCommunity OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"The value of tmnxStgNotifyCommunity specifies the SNMPv1 or
SNMPv2c community name string or the SNMPv3 security name
used when an SNMP notification message is sent to this
trap destination. If the value of this object is the empty
string, then no messages will be sent nor will any counters be
incremented.
This object was made obsolete in the 5.0 release. It is
replaced by tmnxStdVersion."
DEFVAL { ''H }
::= { tmnxSnmpTrapGroupEntry 7 }
tmnxStgSecurityLevel OBJECT-TYPE
SYNTAX SnmpSecurityLevel
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"The value of tmnxStgSecurityLevel specifies the level of security at
which SNMP notification messages will be sent to the SNMP trap
destination when tmnxStgVersion has a value of '3' for SNMPv3.
This object was made obsolete in the 5.0 release. It is
replaced by tmnxStdSecurityLevel."
DEFVAL { noAuthNoPriv }
::= { tmnxSnmpTrapGroupEntry 8 }
tmnxEventTest OBJECT-TYPE
SYNTAX TmnxActionType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting tmnxEventTest to 'doAction' causes the tmnxTestEvent
notification to be generated."
DEFVAL { notApplicable }
::= { tmnxLogObjs 12 }
tmnxEventThrottleLimit OBJECT-TYPE
SYNTAX Unsigned32 (1..20000)
UNITS "events"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxEventThrottleLimit specifies the number of
log events that can be logged within the tmnxEventThrottleInterval
for a specific entry in the tmnxEventTable. Once the limit has
been reached, any additional events of that type will be dropped,
i.e. tmnxEventDropCount will be incremented. At the end of the
throttle interval if any events have been dropped a
tmnxLogEventThrottled notification will be sent."
DEFVAL { 2000 }
::= { tmnxLogObjs 13 }
tmnxEventThrottleInterval OBJECT-TYPE
SYNTAX Unsigned32 (1..1200)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxEventThrottleInterval specifies the number of seconds
that an event throttling interval lasts."
DEFVAL { 1 }
::= { tmnxLogObjs 14 }
tmnxSnmpSetErrsMax OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxSnmpSetErrsMax indicates the maximum number of
entries the agent will create in the tmnxSnmpSetErrsTable. Once the
table is full the agent will delete the oldest entry in the table in
order to add new entries."
::= { tmnxLogObjs 15 }
tmnxSnmpSetErrsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxSnmpSetErrsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of recent SNMP SET failures. Only the SET errs from
remote SNMP manager requests are saved in this table. Only
SET errs detected by the SNMP engine in the test phase
consistency check method functions are saved. SET errors that
are caught by the preliminary access and ASN.1 decoding phase
are not saved. These are errs such as noAccess, notWritable,
wrongType, wrongLength and wrongEncoding. Note that notWritable,
wrongType, and wrongLength errs may sometimes be generated by
the consistency check; in this case they will be saved in this
table.
SET errs caused by local CLI sessions are not saved.
The tmnxSnmpSetErrsTable is intended to provide an aide to
Network Management Systems (NMS) developers. When an SNMP SET
fails during the consistency checking test phase, this table may
provide more detailed failure reason information than the simple
SNMP error code value in the SNMP response PDU."
::= { tmnxLogObjs 16 }
tmnxSnmpSetErrsEntry OBJECT-TYPE
SYNTAX TmnxSnmpSetErrsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular SNMP SET error. The first two
index instances identify the SNMP manager who sent the SNMP SET
request that failed. The third index specifies the SNMP request ID
(sequence number) of the SNMP SET request that failed.
Entries are created by the agent. Entries are deleted by the agent.
There is no StorageType object, entries have a presumed StorageType of
volatile."
INDEX {
tmnxSseAddressType,
tmnxSseAddress,
tmnxSseSnmpPort,
tmnxSseRequestId
}
::= { tmnxSnmpSetErrsTable 1 }
TmnxSnmpSetErrsEntry ::= SEQUENCE
{
tmnxSseAddressType InetAddressType,
tmnxSseAddress InetAddress,
tmnxSseSnmpPort TmnxUdpPort,
tmnxSseRequestId Unsigned32,
tmnxSseVersion SnmpMessageProcessingModel,
tmnxSseSeverityLevel TmnxPerceivedSeverity,
tmnxSseModuleId Unsigned32,
tmnxSseModuleName TNamedItem,
tmnxSseErrorCode Unsigned32,
tmnxSseErrorName DisplayString,
tmnxSseErrorMsg DisplayString,
tmnxSseExtraText OCTET STRING,
tmnxSseTimestamp TimeStamp
}
tmnxSseAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxSseAddressType indicates the IP address
type of address specified in tmnxSseAddress. 'ipv4' and
'ipv6' are the only address type values supported."
::= { tmnxSnmpSetErrsEntry 1 }
tmnxSseAddress OBJECT-TYPE
SYNTAX InetAddress (SIZE (4|16))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxSseAddress is the IP address of the SNMP manager that
sent the SNMP SET request that failed for this error reason."
::= { tmnxSnmpSetErrsEntry 2 }
tmnxSseSnmpPort OBJECT-TYPE
SYNTAX TmnxUdpPort
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxSseSnmpPort is the UDP port number of the SNMP
manager that sent the SNMP SET request that failed for this error
reason."
::= { tmnxSnmpSetErrsEntry 3 }
tmnxSseRequestId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxSseRequestId indicates the request ID of the SNMP
SNMP SET request that failed for this error reason."
::= { tmnxSnmpSetErrsEntry 4 }
tmnxSseVersion OBJECT-TYPE
SYNTAX SnmpMessageProcessingModel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxSseVersion indicates the SNMP version of the SNMP SET
request that failed.
The values supported by the Nokia SROS series SNMP agent are:
0 for SNMPv1
1 for SNMPv2c
3 for SNMPv3"
::= { tmnxSnmpSetErrsEntry 5 }
tmnxSseSeverityLevel OBJECT-TYPE
SYNTAX TmnxPerceivedSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxSseSeverityLevel indicates severity level that is
associated with this type SNMP SET error."
::= { tmnxSnmpSetErrsEntry 6 }
tmnxSseModuleId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxSseModuleId indicates a unique arbitrary
identified for the TiMOS application module that generated
this SNMP SET error. NOTE: This is NOT the same value used
for tmnxEventAppIndex."
::= { tmnxSnmpSetErrsEntry 7 }
tmnxSseModuleName OBJECT-TYPE
SYNTAX TNamedItem
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxSseModuleName indicates the name string of the TiMOS
application module that generated this SNMP SET error. NOTE: This is
NOT the same value used for tmnxEventAppName."
::= { tmnxSnmpSetErrsEntry 8 }
tmnxSseErrorCode OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxSseErrorCode indicates the error number associated
with this SNMP SET error. The error numbers are unique within
a tmnxSseModuleId. They are not unique across all modules so
both the module name and error number are required to identify
a particular error message."
::= { tmnxSnmpSetErrsEntry 9 }
tmnxSseErrorName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxSseErrorName indicates the error name associated
with this SNMP SET error. The error names are unique within
a tmnxSseModuleId. They are not unique across all modules so
both the module name and error name are required to identify
a particular error message."
::= { tmnxSnmpSetErrsEntry 10 }
tmnxSseErrorMsg OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxSseErrorMsg indicates the fixed error message text
associated with this SNMP SET error identified by the values of
tmnxSseModuleId and tmnxSseErrorCode."
::= { tmnxSnmpSetErrsEntry 11 }
tmnxSseExtraText OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..320))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxSseExtraText indicates the fixed run-time variable
message text associated with this SNMP SET error identified by the
values of tmnxSseModuleId and tmnxSseErrorCode. If the extra text
was truncated to fit into buffer size allowed, the last character
will be an asterisk (*)."
::= { tmnxSnmpSetErrsEntry 12 }
tmnxSseTimestamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxSseTimestamp indicates the sysUpTime value when this
tmnxSnmpSetErrsEntry was created by the agent."
::= { tmnxSnmpSetErrsEntry 13 }
tmnxSnmpTrapLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxSnmpTrapLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of all remote SNMP trap logs to which this agent is configured
to send SNMP notifications messages."
::= { tmnxLogObjs 17 }
tmnxSnmpTrapLogEntry OBJECT-TYPE
SYNTAX TmnxSnmpTrapLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row entry in the tmnxSnmpTrapLogTable represents additional
columns for attributes specific to the Nokia SROS series
implementation of SNMP-NOTIFICATION-MIB::snmpNotifyTable."
AUGMENTS { snmpNotifyEntry }
::= { tmnxSnmpTrapLogTable 1 }
TmnxSnmpTrapLogEntry ::= SEQUENCE
{
tmnxSnmpTrapLogDescription TItemDescription,
snmpNotifyId TmnxLogIdIndex
}
tmnxSnmpTrapLogDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxSnmpTrapLogDescription is an administratively
assigned textual description of this snmp trap log."
DEFVAL { ''H }
::= { tmnxSnmpTrapLogEntry 1 }
snmpNotifyId OBJECT-TYPE
SYNTAX TmnxLogIdIndex (1..100)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of snmpNotifyId creates association with log with the same
value of tmnxLogIdIndex. It is number representation of
snmpNotifyName. Usage of default Netconf log 101 not allowed."
::= { tmnxSnmpTrapLogEntry 2 }
tmnxSnmpTrapDestTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxSnmpTrapDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of all remote SNMP IPv4/v6 trap collectors to which this agent
is configured to send SNMP notification messages."
::= { tmnxLogObjs 18 }
tmnxSnmpTrapDestEntry OBJECT-TYPE
SYNTAX TmnxSnmpTrapDestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular SNMP notification destination entry.
The first index instance creates an snmp notification group to be
associated with the event log with the same value for tmnxLogIdIndex.
The second index specifies an administrative name to identify a
specific SNMP notification target.
Entries are created by user. Entries are deleted by user.
There is no StorageType object, entries have a presumed StorageType of
nonVolatile."
INDEX {
tmnxStdIndex,
IMPLIED tmnxStdName
}
::= { tmnxSnmpTrapDestTable 1 }
TmnxSnmpTrapDestEntry ::= SEQUENCE
{
tmnxStdIndex TmnxStgIndex,
tmnxStdName SnmpAdminString,
tmnxStdRowStatus RowStatus,
tmnxStdRowLastChanged TimeStamp,
tmnxStdDestAddrType InetAddressType,
tmnxStdDestAddr InetAddress,
tmnxStdDestPort TmnxUdpPort,
tmnxStdDescription TItemDescription,
tmnxStdVersion SnmpMessageProcessingModel,
tmnxStdNotifyCommunity OCTET STRING,
tmnxStdSecurityLevel SnmpSecurityLevel,
tmnxStdReplay TruthValue,
tmnxStdReplayStart Unsigned32,
tmnxStdReplayLastTime TimeStamp,
tmnxStdDyingGasp TruthValue
}
tmnxStdIndex OBJECT-TYPE
SYNTAX TmnxStgIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxStdIndex specifies an snmp notification group to be
associated with the event log with the same value for tmnxLogIdIndex."
::= { tmnxSnmpTrapDestEntry 1 }
tmnxStdName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..28))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxStdName specifies the name of an snmp notification
destination within the snmp notification group specified by
tmnxLogIdIndex."
::= { tmnxSnmpTrapDestEntry 2 }
tmnxStdRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The tmnxStdRowStatus object allows for dynamic creation and deletion
of row entries in the tmnxSnmpTrapDestTable as well as the activation
and deactivation of these entries.
In order for 'createAndGo' row creation to succeed or status to
transition to 'active' a value must be set for tmnxStdNotifyCommunity.
In order for 'createAndGo' row creation to succeed or status to
transition to 'active' an entry must exist in the
SNMP-NOTIFICATION-MIB::snmpNotifyTable with an snmpNotifyName index
that is the ASCII string representation of the value of tmnxStdIndex.
When this object's value is set to 'notInService (2)', no messages
will be sent to this snmp notification collector and none of its
counters will be incremented.
Refer to the RowStatus convention for further details on the behavior
of this object."
REFERENCE
"RFC2579 (Textual Conventions for SMIv2)"
::= { tmnxSnmpTrapDestEntry 3 }
tmnxStdRowLastChanged OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxStdRowLastChanged indicates the sysUpTime when the
value of a writable object in this row entry was modified."
::= { tmnxSnmpTrapDestEntry 4 }
tmnxStdDestAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxStdDestAddrType specifies the type of
host address to be used for the remote SNMP notification
collector. This object indicates the type of address stored
in the corresponding tmnxStdDestAddr object.
If the value of this object is 'unknown', then no messages will be
sent nor will any counters be incremented.
If tmnxStdDestAddrType is not set in the same PDU with
tmnxStdDestAddr, the set request will fail with an inconsistentValue
error."
DEFVAL { unknown }
::= { tmnxSnmpTrapDestEntry 5 }
tmnxStdDestAddr OBJECT-TYPE
SYNTAX InetAddress (SIZE (0|4|16|20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxStdDestAddr specifies the IP host address to be used
for the remote SNMP notification collector.
The SNMP notification collector IP address type is determined by the
value of the corresponding tmnxStdDestAddrType object.
If the value of this object is empty or all NULLs, then no messages
will be sent nor will any counters be incremented.
If tmnxStdDestAddrType is not set in the same PDU with
tmnxStdDestAddr, the set request will fail with an inconsistentValue
error."
DEFVAL { ''H }
::= { tmnxSnmpTrapDestEntry 6 }
tmnxStdDestPort OBJECT-TYPE
SYNTAX TmnxUdpPort
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxStdDestPort is the UDP port number that is used to
send messages to this remote SNMP notification collector."
DEFVAL { 162 }
::= { tmnxSnmpTrapDestEntry 7 }
tmnxStdDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxStdDescription is an administratively assigned
textual description of this SNMP notification collector."
DEFVAL { ''H }
::= { tmnxSnmpTrapDestEntry 8 }
tmnxStdVersion OBJECT-TYPE
SYNTAX SnmpMessageProcessingModel
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxStdVersion specifies the SNMP version that will be
used to format notification messages sent to this SNMP notification
collector.
The values supported by the Nokia SROS series SNMP agent are:
0 for SNMPv1
1 for SNMPv2c
3 for SNMPv3"
DEFVAL { 3 }
::= { tmnxSnmpTrapDestEntry 9 }
tmnxStdNotifyCommunity OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxStdNotifyCommunity specifies the SNMPv1 or
SNMPv2c community name string or the SNMPv3 security name
used when an SNMP notification message is sent to this
SNMP notification collector. If the value of this object is
the empty string, then no messages will be sent nor will any
counters be incremented."
DEFVAL { ''H }
::= { tmnxSnmpTrapDestEntry 10 }
tmnxStdSecurityLevel OBJECT-TYPE
SYNTAX SnmpSecurityLevel
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxStdSecurityLevel specifies the level of security at
which SNMP notification messages will be sent to the SNMP notification
collector when tmnxStdVersion has a value of '3' for SNMPv3."
DEFVAL { noAuthNoPriv }
::= { tmnxSnmpTrapDestEntry 11 }
tmnxStdReplay OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxStdReplay specifies whether or not to resend
notifications that were generated while this notification destination
did not have a route installed for it in the route tables."
DEFVAL { false }
::= { tmnxSnmpTrapDestEntry 12 }
tmnxStdReplayStart OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxStdReplayStart indicates the SNMP notification
request ID of the first event that could not be generated because
there is no route to this notification target address.
Events will be resent when this notification target address is
readded to the route tables, on either an in-band or out-of-band
interface. The agent searches backwards in the event log and
begins resending events from the oldest event that has a timestamp
<= 5 centiseconds less than the timestamp of the
event with this request ID. Note that if the outage is long
and a large number of events are generated in the meantime,
it is possible that the log memory storage has wrapped and the
event data for this request ID is no longer available. In that case,
the oldest event saved in the log will be the first event resent.
A value of 0 indicates that there are no missed events waiting to be
resent."
::= { tmnxSnmpTrapDestEntry 13 }
tmnxStdReplayLastTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxStdReplayLastTime indicates the sysUpTime when
missed events were last replayed to this SNMP notification target
address. A value of 0 indicates that no missed events have been
replayed to this SNMP notification target address."
::= { tmnxSnmpTrapDestEntry 14 }
tmnxStdDyingGasp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxStdDyingGasp specifies whether the tmnxSysDyingGasp
trap message is to be sent using this SNMP notification target when
the system goes down due to power loss.
tmnxStdDyingGasp can only be set to 'true' on at most 3 SNMP
notification targets."
DEFVAL { false }
::= { tmnxSnmpTrapDestEntry 15 }
tmnxStdMaxTargets OBJECT-TYPE
SYNTAX Unsigned32 (10..100)
UNITS "trap-targets"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of tmnxSnmpTrapDestTable row entries that can be
created for a specific tmnxStdIndex that represents an snmp
notification group."
DEFVAL { 25 }
::= { tmnxLogObjs 19 }
tmnxLogApCustRecordTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogApCustRecordEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Nokia SROS series tmnxLogApCustRecordTable augments
tmnxLogApTable. The table allows to configure the layout and setting
for a custom accounting record associated with this accounting policy."
::= { tmnxLogObjs 20 }
tmnxLogApCustRecordEntry OBJECT-TYPE
SYNTAX TmnxLogApCustRecordEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the tmnxLogApCustRecordTable. Entries in this
table are created and destroyed via SNMP Set requests to the
tmnxLogApRowStatus object of the tmnxLogApTable."
AUGMENTS { tmnxLogApEntry }
::= { tmnxLogApCustRecordTable 1 }
TmnxLogApCustRecordEntry ::= SEQUENCE
{
tmnxLogApCrLastChanged TimeStamp,
tmnxLogApCrSignChangeDelta Unsigned32,
tmnxLogApCrSignChangeQueue TQueueIdOrAll,
tmnxLogApCrSignChangeOCntr THsmdaCounterIdOrZeroOrAll,
tmnxLogApCrSignChangeQICounters TmnxAccPlcyQICounters,
tmnxLogApCrSignChangeQECounters TmnxAccPlcyQECounters,
tmnxLogApCrSignChangeOICounters TmnxAccPlcyOICounters,
tmnxLogApCrSignChangeOECounters TmnxAccPlcyOECounters,
tmnxLogApCrSignChangeAACounters TmnxAccPlcyAACounters,
tmnxLogApCrAACounters TmnxAccPlcyAACounters,
tmnxLogApCrAASubAttributes TmnxAccPlcyAASubAttributes,
tmnxLogApCrSignChangePolicer Integer32,
tmnxLogApCrSignChangePICounters TmnxAccPlcyPolicerICounters,
tmnxLogApCrSignChangePECounters TmnxAccPlcyPolicerECounters
}
tmnxLogApCrLastChanged OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogApCrLastChanged indicates the sysUpTime when an
object in this table was last modified. A Value 0 means that no change
was made to this row since the box was last initialized."
::= { tmnxLogApCustRecordEntry 1 }
tmnxLogApCrSignChangeDelta OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogApCrSignChangeDelta specifies the delta
change (significant change) that is required for the custom record
to be written to the xml file."
DEFVAL { 0 }
::= { tmnxLogApCustRecordEntry 2 }
tmnxLogApCrSignChangeQueue OBJECT-TYPE
SYNTAX TQueueIdOrAll
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogApCrSignChangeQueue specifies the reference queue
to which the significant change defined in tmnxLogApCrSignChangeDelta
applies."
DEFVAL { 0 }
::= { tmnxLogApCustRecordEntry 3 }
tmnxLogApCrSignChangeOCntr OBJECT-TYPE
SYNTAX THsmdaCounterIdOrZeroOrAll
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The value of tmnxLogApCrSignChangeOCntr specifies the counter-id that
will be taken as reference to which the significant change defined in
tmnxLogApCrSignChangeDelta applies."
DEFVAL { 0 }
::= { tmnxLogApCustRecordEntry 4 }
tmnxLogApCrSignChangeQICounters OBJECT-TYPE
SYNTAX TmnxAccPlcyQICounters
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogApCrSignChangeQICounters specifies the ingress
counter Ids in the queue defined by tmnxLogApCrSignChangeQueue to be
taken as reference to which the significant change defined in
tmnxLogApCrSignChangeDelta applies.
A non-zero value of this object is only allowed if the object
tmnxLogApCrSignChangeQueue has a non-zero value."
DEFVAL { {} }
::= { tmnxLogApCustRecordEntry 5 }
tmnxLogApCrSignChangeQECounters OBJECT-TYPE
SYNTAX TmnxAccPlcyQECounters
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogApCrSignChangeQECounters specifies the egress
counter Ids in the queue defined by tmnxLogApCrSignChangeQueue to be
taken as reference to which the significant change defined in
tmnxLogApCrSignChangeDelta applies.
A non-zero value of this object is only allowed if the object
tmnxLogApCrSignChangeQueue has a non-zero value."
DEFVAL { {} }
::= { tmnxLogApCustRecordEntry 6 }
tmnxLogApCrSignChangeOICounters OBJECT-TYPE
SYNTAX TmnxAccPlcyOICounters
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The value of tmnxLogApCrSignChangeOICounters specifies the ingress
counter Ids in the counter-group defined by tmnxLogApCrSignChangeOCntr
to be taken as reference to which the significant change defined in
tmnxLogApCrSignChangeDelta applies.
A non-zero value of this object is only allowed if the object
tmnxLogApCrSignChangeOCntr has a non-zero value."
DEFVAL { {} }
::= { tmnxLogApCustRecordEntry 7 }
tmnxLogApCrSignChangeOECounters OBJECT-TYPE
SYNTAX TmnxAccPlcyOECounters
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The value of tmnxLogApCrSignChangeOECounters specifies the egress
counter Ids in the counter-group defined by tmnxLogApCrSignChangeOCntr
to be taken as reference to which the significant change defined in
tmnxLogApCrSignChangeDelta applies.
A non-zero value of this object is only allowed if the object
tmnxLogApCrSignChangeOCntr has a non-zero value."
DEFVAL { {} }
::= { tmnxLogApCustRecordEntry 8 }
tmnxLogApCrSignChangeAACounters OBJECT-TYPE
SYNTAX TmnxAccPlcyAACounters
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogApCrSignChangeAACounters specifies the
AA (Application assurance) counter Ids to be taken as reference to
which the significant change defined in tmnxLogApCrSignChangeDelta
applies.
A non-zero value of this object is only allowed if both the objects
tmnxLogApCrSignChangeOCntr and tmnxLogApCrSignChangeQueue are zero.
Also, a non-zero value for this object is only allowed if the object
tmnxLogApCrSignChangeDelta is either 0 or 1."
DEFVAL { {} }
::= { tmnxLogApCustRecordEntry 9 }
tmnxLogApCrAACounters OBJECT-TYPE
SYNTAX TmnxAccPlcyAACounters
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogApCrAACounters specifies the list of AA
(Application Assurance) counters that need to be collected in this
custom record."
DEFVAL { {} }
::= { tmnxLogApCustRecordEntry 10 }
tmnxLogApCrAASubAttributes OBJECT-TYPE
SYNTAX TmnxAccPlcyAASubAttributes
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogApCrAASubAttributes specifies the list of AA
(Application Assurance) subscriber attributes that must be included in
this custom record."
DEFVAL { {} }
::= { tmnxLogApCustRecordEntry 11 }
tmnxLogApCrSignChangePolicer OBJECT-TYPE
SYNTAX Integer32 (-1 | 0..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogApCrSignChangePolicer specifies the reference
policer to which the significant change defined in
tmnxLogApCrSignChangeDelta applies.
A value of zero means that the significant change does not apply to
any policer.
A value of minus one means that the significant change applies to any
policer."
DEFVAL { 0 }
::= { tmnxLogApCustRecordEntry 12 }
tmnxLogApCrSignChangePICounters OBJECT-TYPE
SYNTAX TmnxAccPlcyPolicerICounters
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogApCrSignChangePICounters specifies the ingress
counters in the policer defined by tmnxLogApCrSignChangePolicer to
which the significant change defined in tmnxLogApCrSignChangeDelta
applies.
A non-empty value of this object is only allowed if the object
tmnxLogApCrSignChangePolicer has a non-zero value."
DEFVAL { {} }
::= { tmnxLogApCustRecordEntry 13 }
tmnxLogApCrSignChangePECounters OBJECT-TYPE
SYNTAX TmnxAccPlcyPolicerECounters
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogApCrSignChangePECounters specifies the egress
counters in the policer defined by tmnxLogApCrSignChangePolicer to
which the significant change defined in tmnxLogApCrSignChangeDelta
applies.
A non-empty value of this object is only allowed if the object
tmnxLogApCrSignChangeQueue has a non-zero value."
DEFVAL { {} }
::= { tmnxLogApCustRecordEntry 14 }
tmnxLogApCustRecordQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogApCustRecordQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Nokia SROS series tmnxLogApCustRecordQueueTable allows to create
custom record queue information for a given accounting policy. Rows
can only be created for existing accounting policies (as defined in
tmnxLogApTable)."
::= { tmnxLogObjs 21 }
tmnxLogApCustRecordQueueEntry OBJECT-TYPE
SYNTAX TmnxLogApCustRecordQueueEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the tmnxLogApCustRecordQueueTable. Entries in this
table are created and destroyed via SNMP Set requests."
INDEX {
tmnxLogApPolicyId,
tmnxLogApCrQueueId
}
::= { tmnxLogApCustRecordQueueTable 1 }
TmnxLogApCustRecordQueueEntry ::= SEQUENCE
{
tmnxLogApCrQueueId TQueueId,
tmnxLogApCrQueueRowStatus RowStatus,
tmnxLogApCrQueueLastChanged TimeStamp,
tmnxLogApCrQueueICounters TmnxAccPlcyQICounters,
tmnxLogApCrQueueECounters TmnxAccPlcyQECounters
}
tmnxLogApCrQueueId OBJECT-TYPE
SYNTAX TQueueId (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxLogApCrQueueId specifies the queue ID for which
counters will be collected in this custom record. The counters that
will be collected are defined in tmnxLogApCrQueueICounters and
tmnxLogApCrQueueECounters."
::= { tmnxLogApCustRecordQueueEntry 1 }
tmnxLogApCrQueueRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row Status of the entry. This allows creation/deletion of rows in this
table."
::= { tmnxLogApCustRecordQueueEntry 2 }
tmnxLogApCrQueueLastChanged OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogApCrQueueLastChanged indicates the sysUpTime when
an object in this table was last modified. A Value 0 means that no
change was made to this row since it was created."
::= { tmnxLogApCustRecordQueueEntry 3 }
tmnxLogApCrQueueICounters OBJECT-TYPE
SYNTAX TmnxAccPlcyQICounters
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogApCrQueueICounters specifies the list of ingress
counters that need to be collected in this custom record.
At least one of the objects tmnxLogApCrQueueICounters or
tmnxLogApCrQueueECounters must have a non-zero value."
DEFVAL { {} }
::= { tmnxLogApCustRecordQueueEntry 4 }
tmnxLogApCrQueueECounters OBJECT-TYPE
SYNTAX TmnxAccPlcyQECounters
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogApCrQueueECounters specifies the list of egress
counters that need to be collected in this custom record.
At least one of the objects tmnxLogApCrQueueICounters or
tmnxLogApCrQueueECounters must have a non-zero value."
DEFVAL { {} }
::= { tmnxLogApCustRecordQueueEntry 5 }
tmnxLogApCrOverrideCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogApCrOverrideCntrEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"The Nokia SROS series tmnxLogApCrOverrideCntrTable allows to create
custom record counter override information for a given accounting
policy.
Rows can only be created for existing accounting policies (as defined
in tmnxLogApTable)."
::= { tmnxLogObjs 22 }
tmnxLogApCrOverrideCntrEntry OBJECT-TYPE
SYNTAX TmnxLogApCrOverrideCntrEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Defines an entry in the tmnxLogApCrOverrideCntrTable. Entries in this
table are created and destroyed via SNMP Set requests."
INDEX {
tmnxLogApPolicyId,
tmnxLogApCrOverrideCntrId
}
::= { tmnxLogApCrOverrideCntrTable 1 }
TmnxLogApCrOverrideCntrEntry ::= SEQUENCE
{
tmnxLogApCrOverrideCntrId THsmdaCounterIdOrZero,
tmnxLogApCrOverrideCntrRowStatus RowStatus,
tmnxLogApCrOverrideCntrLastChngd TimeStamp,
tmnxLogApCrOverrideCntrICounters TmnxAccPlcyOICounters,
tmnxLogApCrOverrideCntrECounters TmnxAccPlcyOECounters
}
tmnxLogApCrOverrideCntrId OBJECT-TYPE
SYNTAX THsmdaCounterIdOrZero (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxLogApCrOverrideCntrId specifies the counter group for
which counters will be collected in this custom record. The counters
that will be collected are defined in tmnxLogApCrOverrideCntrICounters
and tmnxLogApCrOverrideCntrECounters."
::= { tmnxLogApCrOverrideCntrEntry 1 }
tmnxLogApCrOverrideCntrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"Row Status of the entry. This allows creation/deletion of rows in this
table."
::= { tmnxLogApCrOverrideCntrEntry 2 }
tmnxLogApCrOverrideCntrLastChngd OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The value of tmnxLogApCrOverrideCntrLastChngd indicates the sysUpTime
when an object in this table was last modified. A Value 0 means that
no change was made to this row since it was created."
::= { tmnxLogApCrOverrideCntrEntry 3 }
tmnxLogApCrOverrideCntrICounters OBJECT-TYPE
SYNTAX TmnxAccPlcyOICounters
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"The value of tmnxLogApCrOverrideCntrICounters specifies the list of
ingress counters that need to be collected in this custom record.
At least one of the objects tmnxLogApCrOverrideCntrICounters or
tmnxLogApCrOverrideCntrECounters must have a non-zero value."
DEFVAL { {} }
::= { tmnxLogApCrOverrideCntrEntry 4 }
tmnxLogApCrOverrideCntrECounters OBJECT-TYPE
SYNTAX TmnxAccPlcyOECounters
MAX-ACCESS read-create
STATUS obsolete
DESCRIPTION
"The value of tmnxLogApCrOverrideCntrECounters specifies the list of
egress counters that need to be collected in this custom record.
At least one of the objects tmnxLogApCrOverrideCntrICounters or
tmnxLogApCrOverrideCntrECounters must have a non-zero value."
DEFVAL { {} }
::= { tmnxLogApCrOverrideCntrEntry 5 }
tmnxEventPrimaryRoutePref OBJECT-TYPE
SYNTAX INTEGER {
inband (1),
outband (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxEventPrimaryRoutePref specifies the primary routing
preference for traffic generated for SNMP notifications and syslog
messages.
A value of 'inband' specifies that the Logging utility will attempt to
use the Base routing context to send SNMP notifications and syslog
messages to remote destinations.
A value of 'outband' specifies that the Logging utility will attempt
to use the management routing context to send SNMP notifications and
syslog messages to remote destinations.
If the remote destination, as specified by tmnxStdDestAddr or
tmnxSyslogTargetAddr, is not reachable via the routing context
specified by tmnxEventPrimaryRoutePref, the secondary routing
preference as specified by tmnxEventSecondaryRoutePref will be
attempted."
DEFVAL { outband }
::= { tmnxLogObjs 23 }
tmnxEventSecondaryRoutePref OBJECT-TYPE
SYNTAX INTEGER {
inband (1),
outband (2),
none (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxEventSecondaryRoutePref specifies the secondary
routing preference for traffic generated for SNMP notifications and
syslog messages. The routing context specified by the
tmnxEventSecondaryRoutePref will be attempted if the remote
destination was not reachable by the primary routing preference,
specified by tmnxEventPrimaryRoutePref. The value specified for
tmnxEventSecondaryRoutePref must be distinct from the value for
tmnxEventPrimaryRoutePref.
A value of 'inband' specifies that the Logging utility will attempt to
use the Base routing context to send SNMP notifications and syslog
messages to remote destinations.
A value of 'outband' specifies that the Logging utility will attempt
to use the management routing context to send SNMP notifications and
syslog messages to remote destinations.
A value of 'none' specifies that no attempt will be made to send SNMP
notifications and syslog messages to remote destinations.
If the remote destination, as specified by tmnxStdDestAddr or
tmnxSyslogTargetAddr, is not reachable via the routing contexts
specified by tmnxEventPrimaryRoutePref and
tmnxEventSecondaryRoutePref, the Log utility will fail to send SNMP
notifications and syslog messages to the remote destination."
DEFVAL { inband }
::= { tmnxLogObjs 24 }
tmnxLogConfigEventsDamped OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogConfigEventsDamped specifies whether or not the
module generating tmnxConfigCreate, tmnxConfigDelete, and
tmnxConfigModify events applies a damping algorithm.
WARNING: While this event damping is original behavior
for some modules such as service manager, QoS, and filters it
can result in the NMS system database being out of sync because
of missed change events. On the other hand, if the damping
is disabled, 'false', it may take much longer for a large
CLI configuration file to be processed when manually 'exec'ed
after system bootup."
DEFVAL { true }
::= { tmnxLogObjs 25 }
tmnxLogEventHistoryObjs OBJECT IDENTIFIER ::= { tmnxLogObjs 26 }
tmnxLogEventHistGeneralObjs OBJECT IDENTIFIER ::= { tmnxLogEventHistoryObjs 1 }
tmnxLogExRbkOpTblLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the object tmnxLogExRbkOpTblLastChange indicates the
value of sysUpTime at the time of the last modification of a row entry
in the tmnxLogExecRollbackOpTable."
::= { tmnxLogEventHistGeneralObjs 1 }
tmnxLogExRbkOpMaxEntries OBJECT-TYPE
SYNTAX Unsigned32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the object tmnxLogExRbkOpMaxEntries specifies the maximum
number of row entries supported in the tmnxLogExecRollbackOpTable."
DEFVAL { 5 }
::= { tmnxLogEventHistGeneralObjs 2 }
tmnxLogExecRollbackOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogExecRollbackOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Nokia SROS series tmnxLogExecRollbackOpTable provides a history of
up to the last number of 'exec', 'load', rollback revert, and 'vsd'
operations specified by the value of tmnxLogExRbkOpMaxEntries.
The tmnxLogExecRollbackOpTable is intended to provide an aide to
Network Management Systems (NMS). The 'exec' or 'load' of a large
configuration file via the system's CLI, a large rollback revert
operation, or execution of 'vsd' configuration messages will generate
so many configuration change and other events in a short time that
neither the SROS's event logging utility nor the NMS can keep up with
them. This results in the SROS and/or NMS dropping events and requires
the NMS to perform a costly resynchronization of its management
database."
::= { tmnxLogEventHistoryObjs 3 }
tmnxLogExecRollbackOpEntry OBJECT-TYPE
SYNTAX TmnxLogExecRollbackOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines a row entry in the tmnxLogExecRollbackOpTable. Entries in this
table are created and deleted by the agent."
INDEX { tmnxLogExRbkOpIndex }
::= { tmnxLogExecRollbackOpTable 1 }
TmnxLogExecRollbackOpEntry ::= SEQUENCE
{
tmnxLogExRbkOpIndex Unsigned32,
tmnxLogExRbkOpLastChanged TimeStamp,
tmnxLogExRbkOpType TmnxLogExRbkOperationType,
tmnxLogExRbkOpStatus INTEGER,
tmnxLogExRbkOpBegin TimeStamp,
tmnxLogExRbkOpEnd TimeStamp,
tmnxLogExRbkOpFile DisplayString,
tmnxLogExRbkOpUser TNamedItemOrEmpty,
tmnxLogExRbkOpNumEvents Unsigned32
}
tmnxLogExRbkOpIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxLogExRbkOpIndex is a unique value that indicates an
instance of an exec, load, rollback revert, or vsd operation. Only the
most recent instances are kept in this table. The maximum number of
row entries supported in this table is specified by the value of
tmnxLogExRbkOpMaxEntries."
::= { tmnxLogExecRollbackOpEntry 1 }
tmnxLogExRbkOpLastChanged OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogExRbkOpLastChanged indicates the sysUpTime when an
object in this table was last modified. A Value 0 means that no change
was made to this row since it was created."
::= { tmnxLogExecRollbackOpEntry 2 }
tmnxLogExRbkOpType OBJECT-TYPE
SYNTAX TmnxLogExRbkOperationType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogExRbkOpType indicates the type of operation this
row entry represents."
::= { tmnxLogExecRollbackOpEntry 3 }
tmnxLogExRbkOpStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown (0),
inProgress (1),
success (2),
failed (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogExRbkOpStatus indicates the status of this exec,
load, rollback revert, or vsd operation."
::= { tmnxLogExecRollbackOpEntry 4 }
tmnxLogExRbkOpBegin OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogExRbkOpBegin indicates the sysUpTime when the
exec, load, rollback revert, or vsd operation began."
::= { tmnxLogExecRollbackOpEntry 5 }
tmnxLogExRbkOpEnd OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogExRbkOpEnd indicates the sysUpTime when the exec,
load, rollback revert, or vsd operation ended. A value of zero (0)
means that the operation has not completed."
::= { tmnxLogExecRollbackOpEntry 6 }
tmnxLogExRbkOpFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogExRbkOpFile indicates the location and name of the
file used for the exec, load or rollback revert operation, otherwise
the value of this object is an empty string."
::= { tmnxLogExecRollbackOpEntry 7 }
tmnxLogExRbkOpUser OBJECT-TYPE
SYNTAX TNamedItemOrEmpty
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogExRbkOpUser indicates the user who initiated the
exec or rollback revert operation."
::= { tmnxLogExecRollbackOpEntry 8 }
tmnxLogExRbkOpNumEvents OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogExRbkOpNumEvents indicates the number of
row entries in the associated tmnxLogExecRollbackEventTable
for this exec, load, rollback revert, or vsd operation.
It is updated only when the exec, load, rollback revert, or vsd
operation ends. A value of zero (0) means that the operatio
has not completed."
::= { tmnxLogExecRollbackOpEntry 9 }
tmnxLogExecRollbackEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogExecRollbackEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Nokia SROS series tmnxLogExecRollbackEventTable provides a history
of mib tables modified or specific events generated during an exec,
load, rollback revert, or vsd operation."
::= { tmnxLogEventHistoryObjs 4 }
tmnxLogExecRollbackEventEntry OBJECT-TYPE
SYNTAX TmnxLogExecRollbackEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines a row entry in the tmnxLogExecRollbackEventTable. Each row
entry represents either an SNMP table that has been modified or a
specific event generated during an exec, load, rollback revert, or vsd
operation. Entries in this table are created and deleted by the agent."
INDEX {
tmnxLogExRbkOpIndex,
tmnxLogExRbkEventIndex
}
::= { tmnxLogExecRollbackEventTable 1 }
TmnxLogExecRollbackEventEntry ::= SEQUENCE
{
tmnxLogExRbkEventIndex Unsigned32,
tmnxLogExRbkEventOID OBJECT IDENTIFIER
}
tmnxLogExRbkEventIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxLogExRbkEventIndex is a unique value that indicates
an instance of an event generated during an exec, load, rollback
revert, or vsd operation."
::= { tmnxLogExecRollbackEventEntry 1 }
tmnxLogExRbkEventOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogExRbkEventOID indicates the object identifier of
either a mib table for which a generic change event was generated or
the notification object identifier of a specific event notification
generated during the the exec, load, rollback revert, or vsd
operation.
The generic change events are tmnxConfigCreate, tmnxConfigDelete,
tmnxConfigModify, and tmnxStateChange notifications. For these
event types, the value of tmnxLogExRbkEventOID is the object
identifier specified by the tmnxNotifyEntryOID varbind.
For specific events generated during an exec, load or rollback revert
or vsd, the value of this object is the notification object identifier
itself.
An object identifier will appear only once in this table."
::= { tmnxLogExecRollbackEventEntry 2 }
tmnxLogExRbkNotifyObjects OBJECT IDENTIFIER ::= { tmnxLogEventHistoryObjs 5 }
tmnxLogExecRollbackOpIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogExecRollbackOpIndex is a unique value that
indicates a row entry instance of an exec, load, rollback revert,
or vsd operation in the tmnxLogExecRollbackOpTable. It is included
in the 'exec', 'load' and rollback revert start and end notifications."
::= { tmnxLogExRbkNotifyObjects 1 }
tmnxLogExecRollbackOpType OBJECT-TYPE
SYNTAX TmnxLogExRbkOperationType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of tmnxLogExecRollbackOpType indicates the type of
operation being performed. It is included in the 'exec', 'load'
and rollback revert start and end notifications."
::= { tmnxLogExRbkNotifyObjects 2 }
tmnxLogColdStartWaitTime OBJECT-TYPE
SYNTAX Unsigned32 (0..300)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogColdStartWaitTime specifies the time delay that
must pass before notifying specific CPM applications that a route is
available after a cold reboot."
DEFVAL { 0 }
::= { tmnxLogObjs 27 }
tmnxLogRouteRecoveryWaitTime OBJECT-TYPE
SYNTAX Unsigned32 (0..100)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of tmnxLogRouteRecoveryWaitTime specifies the time delay
that must pass before notifying specific CPM applications after the
recovery or change of a route during normal operation."
DEFVAL { 0 }
::= { tmnxLogObjs 28 }
tmnxEhsObjs OBJECT IDENTIFIER ::= { tmnxLogObjs 29 }
tmnxEhsGeneralObjs OBJECT IDENTIFIER ::= { tmnxEhsObjs 1 }
tmnxEhsHandlerTblLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the object tmnxEhsHandlerTblLastChange indicates the
value of sysUpTime at the time of the last modification of a row in
the tmnxEhsHandlerTable."
::= { tmnxEhsGeneralObjs 1 }
tmnxEhsHandlerMaxEntries OBJECT-TYPE
SYNTAX Unsigned32 (0..5000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the object tmnxEhsHandlerMaxEntries specifies the maximum
number of row entries supported in the tmnxEhsHandlerTable."
DEFVAL { 1500 }
::= { tmnxEhsGeneralObjs 2 }
tmnxEhsHEntryTblLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the object tmnxEhsHEntryTblLastChange indicates the value
of sysUpTime at the time of the last modification of a row in the
tmnxEhsHEntryTable."
::= { tmnxEhsGeneralObjs 3 }
tmnxEhsHEntryMaxEntries OBJECT-TYPE
SYNTAX Unsigned32 (0..5000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the object tmnxEhsHEntryMaxEntries specifies the maximum
number of row entries supported in the tmnxEhsHEntryTable."
DEFVAL { 1500 }
::= { tmnxEhsGeneralObjs 4 }
tmnxEhsTriggerTblLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the object tmnxEhsTriggerTblLastChange indicates the
value of sysUpTime at the time of the last modification of a row in
the tmnxEhsTriggerTable."
::= { tmnxEhsGeneralObjs 5 }
tmnxEhsTriggerMaxEntries OBJECT-TYPE
SYNTAX Unsigned32 (0..5000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the object tmnxEhsTriggerMaxEntries specifies the maximum
number of rows supported in the tmnxEhsTriggerTable."
DEFVAL { 1500 }
::= { tmnxEhsGeneralObjs 6 }
tmnxEhsTEntryTblLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the object tmnxEhsTEntryTblLastChange indicates the value
of sysUpTime at the time of the last modification of a row entry in
the tmnxEhsTEntryTable."
::= { tmnxEhsGeneralObjs 7 }
tmnxEhsTEntryMaxEntries OBJECT-TYPE
SYNTAX Unsigned32 (0..5000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the object tmnxEhsTEntryMaxEntries specifies the maximum
number of row entries supported in the tmnxEhsTEntryTable."
DEFVAL { 1500 }
::= { tmnxEhsGeneralObjs 8 }
tmnxEhsHandlerTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxEhsHandlerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxEhsHandlerTable contains a list of Event Handlers used by the
Event Handling System (EHS) Event Triggers."
::= { tmnxEhsObjs 2 }
tmnxEhsHandlerEntry OBJECT-TYPE
SYNTAX TmnxEhsHandlerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines a row entry in the tmnxEhsHandlerTable. Each entry
contains information about a specific Event Handling System (EHS)
Event Handler.
Rows are created and deleted via SNMP SET operations using
tmnxEhsHandlerRowStatus."
INDEX { tmnxEhsHandlerName }
::= { tmnxEhsHandlerTable 1 }
TmnxEhsHandlerEntry ::= SEQUENCE
{
tmnxEhsHandlerName TNamedItem,
tmnxEhsHandlerRowStatus RowStatus,
tmnxEhsHandlerDescription TItemDescription,
tmnxEhsHandlerLastChange TimeStamp,
tmnxEhsHandlerAdminStatus TmnxAdminState,
tmnxEhsHandlerOperStatus TmnxOperState
}
tmnxEhsHandlerName OBJECT-TYPE
SYNTAX TNamedItem
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxEhsHandlerName specifies the name of an Event
Handling System (EHS) Event Handler represented by this row in the
tmnxEhsHandlerTable."
::= { tmnxEhsHandlerEntry 1 }
tmnxEhsHandlerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsHandlerRowStatus specifies
the row status. It allows rows to be created
and deleted in the tmnxEhsHandlerTable.
If any associated rows exist in the tmnxEhsHEntryTable,
'destroy' will fail. All associated rows must be
destroyed first."
REFERENCE
"See definition of RowStatus in RFC 2579, 'Textual
Conventions for SMIv2.'"
::= { tmnxEhsHandlerEntry 2 }
tmnxEhsHandlerDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsHandlerDescription specifies a user provided
description string for an EHS Handler. It can consist of any
printable, seven-bit ASCII characters up to 80 characters in length."
DEFVAL { ''H }
::= { tmnxEhsHandlerEntry 3 }
tmnxEhsHandlerLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHandlerLastChange indicates the time this row
entry was last changed."
::= { tmnxEhsHandlerEntry 4 }
tmnxEhsHandlerAdminStatus OBJECT-TYPE
SYNTAX TmnxAdminState
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsHandlerAdminStatus specifies the administrative
state of the EHS Event Handler."
DEFVAL { outOfService }
::= { tmnxEhsHandlerEntry 5 }
tmnxEhsHandlerOperStatus OBJECT-TYPE
SYNTAX TmnxOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHandlerOperStatus indicates the operational state
of the EHS Event Handler."
::= { tmnxEhsHandlerEntry 6 }
tmnxEhsHandlerStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxEhsHandlerStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxEhsHandlerStatsTable contains operational data for Event
handlers used by the EHS Event Triggers."
::= { tmnxEhsObjs 3 }
tmnxEhsHandlerStatsEntry OBJECT-TYPE
SYNTAX TmnxEhsHandlerStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines a row in the tmnxEhsHandlerStatsTable. Each row contains
operational information about a specific EHS Event Handler.
Rows are created and deleted by the system as rows are created and
deleted in the tmnxEhsHandlerTable."
AUGMENTS { tmnxEhsHandlerEntry }
::= { tmnxEhsHandlerStatsTable 1 }
TmnxEhsHandlerStatsEntry ::= SEQUENCE
{
tmnxEhsHandlerStatsSuccess Unsigned32,
tmnxEhsHandlerStatsErrNoEntry Unsigned32,
tmnxEhsHandlerStatsErrAdmStatus Unsigned32
}
tmnxEhsHandlerStatsSuccess OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHandlerStatsSuccess indicates the number of times
the EHS system triggers a handler, which can take corresponding action
specified in handler's entries"
::= { tmnxEhsHandlerStatsEntry 1 }
tmnxEhsHandlerStatsErrNoEntry OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHandlerStatsErrNoEntry indicates the number of
times the EHS system triggers a handler, which can not take
corresponding action as there is no handler's entry specifying an
operation to perform."
::= { tmnxEhsHandlerStatsEntry 2 }
tmnxEhsHandlerStatsErrAdmStatus OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHandlerStatsErrAdmStatus indicates the number of
times the EHS system triggers a handler, which can not take
corresponding action due to admin state of the handler.
The handler may be out-of-service due to tmnxEhsHandlerAdminStatus
being set to 'outOfService (3)'."
::= { tmnxEhsHandlerStatsEntry 3 }
tmnxEhsHEntryTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxEhsHEntryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxEhsHEntryTable contains a list of Event Handler Entries in an
EHS Event Handler."
::= { tmnxEhsObjs 4 }
tmnxEhsHEntryEntry OBJECT-TYPE
SYNTAX TmnxEhsHEntryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines a row in the tmnxEhsHEntryTable. Each row
contains information about a specific Handler Entry.
Rows are created and deleted via SNMP SET operations using
tmnxEhsHEntryRowStatus."
INDEX {
tmnxEhsHandlerName,
tmnxEhsHEntryId
}
::= { tmnxEhsHEntryTable 1 }
TmnxEhsHEntryEntry ::= SEQUENCE
{
tmnxEhsHEntryId Unsigned32,
tmnxEhsHEntryRowStatus RowStatus,
tmnxEhsHEntryDescription TItemDescription,
tmnxEhsHEntryLastChange TimeStamp,
tmnxEhsHEntryAdminStatus TmnxAdminState,
tmnxEhsHEntryOperStatus TmnxOperState,
tmnxEhsHEntryScriptPlcyName TNamedItemOrEmpty,
tmnxEhsHEntryScriptPlcyOwner TNamedItemOrEmpty,
tmnxEhsHEntryMinDelay Unsigned32,
tmnxEhsHEntryLastExecuted TimeStamp
}
tmnxEhsHEntryId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryId specifies the index of an Event Entry in
the EHS Event Handler indicated by the value of tmnxEhsHandlerName."
::= { tmnxEhsHEntryEntry 1 }
tmnxEhsHEntryRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryRowStatus specifies
the row status. It allows rows to be created
and deleted in the tmnxEhsHEntryTable.
If an associated row does not exist in the tmnxEhsHandlerTable, a
attempt to create a row will fail."
REFERENCE
"See definition of RowStatus in RFC 2579, 'Textual
Conventions for SMIv2.'"
::= { tmnxEhsHEntryEntry 2 }
tmnxEhsHEntryDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryDescription specifies a user provided
description string for EHS Event Handler Entry. It can consist of any
printable, seven-bit ASCII characters up to 80 characters in length."
DEFVAL { ''H }
::= { tmnxEhsHEntryEntry 3 }
tmnxEhsHEntryLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryLastChange indicates the time this row was
last changed."
::= { tmnxEhsHEntryEntry 4 }
tmnxEhsHEntryAdminStatus OBJECT-TYPE
SYNTAX TmnxAdminState
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryAdminStatus specifies the administrative
state of the EHS Event Handler Entry."
DEFVAL { inService }
::= { tmnxEhsHEntryEntry 5 }
tmnxEhsHEntryOperStatus OBJECT-TYPE
SYNTAX TmnxOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryOperStatus indicates the operational state
of the EHS Event Handler Entry."
::= { tmnxEhsHEntryEntry 6 }
tmnxEhsHEntryScriptPlcyName OBJECT-TYPE
SYNTAX TNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryScriptPlcyName in combination with the value
of tmnxEhsHEntryScriptPlcyOwner specifies the script policy that can
be launched from this tmnxEhsHEntryTable row. The zero-length string
may be used to point to a non-existing script policy."
DEFVAL { ''H }
::= { tmnxEhsHEntryEntry 7 }
tmnxEhsHEntryScriptPlcyOwner OBJECT-TYPE
SYNTAX TNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryScriptPlcyOwner in combination with the
value of tmnxEhsHEntryScriptPlcyName specifies the script policy that
can be launched from this tmnxEhsHEntryTable row. The zero-length
string may be used to point to a non-existing script policy."
DEFVAL { ''H }
::= { tmnxEhsHEntryEntry 8 }
tmnxEhsHEntryMinDelay OBJECT-TYPE
SYNTAX Unsigned32 (0..604800)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryMinDelay specifies the minimum
time, in seconds, between executions of the script policy
specified by this EHS Event Handler Entry. A '0' value means
no delay is imposed."
DEFVAL { 0 }
::= { tmnxEhsHEntryEntry 9 }
tmnxEhsHEntryLastExecuted OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryLastExecuted indicates the time when handler
entry launch execution of action."
::= { tmnxEhsHEntryEntry 10 }
tmnxEhsHEntryStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxEhsHEntryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxEhsHEntryStatsTable contains operational data for Event
Handler Entries used by an EHS Event Handler."
::= { tmnxEhsObjs 5 }
tmnxEhsHEntryStatsEntry OBJECT-TYPE
SYNTAX TmnxEhsHEntryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines a row entry in the tmnxEhsHEntryStatsTable. Each row contains
operational information about a specific EHS Event Handler Entry.
Rows are created and deleted by the system as rows are created and
deleted in the tmnxEhsHEntryTable."
AUGMENTS { tmnxEhsHEntryEntry }
::= { tmnxEhsHEntryStatsTable 1 }
TmnxEhsHEntryStatsEntry ::= SEQUENCE
{
tmnxEhsHEntryStatsLaunchSuccess Unsigned32,
tmnxEhsHEntryStatsErrMinDelay Unsigned32,
tmnxEhsHEntryStatsErrLaunch Unsigned32,
tmnxEhsHEntryStatsErrAdmStatus Unsigned32
}
tmnxEhsHEntryStatsLaunchSuccess OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryStatsLaunchSuccess indicates the number of
successfully queued scripts by EHS handler entry."
::= { tmnxEhsHEntryStatsEntry 1 }
tmnxEhsHEntryStatsErrMinDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryStatsErrMinDelay indicates the number of
cancelled script executions due to tmnxEhsHEntryMinDelay."
::= { tmnxEhsHEntryStatsEntry 2 }
tmnxEhsHEntryStatsErrLaunch OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryStatsErrLaunch indicates the number of
cancelled script executions due to launch failure."
::= { tmnxEhsHEntryStatsEntry 3 }
tmnxEhsHEntryStatsErrAdmStatus OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsHEntryStatsErrAdmStatus indicates the number of
cancelled script executions due to admin state of the handler entry.
The handler entry may be out-of-service due to
tmnxEhsHEntryAdminStatus being set to 'outOfService (3)'."
::= { tmnxEhsHEntryStatsEntry 4 }
tmnxEhsTriggerTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxEhsTriggerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxEhsTriggerTable contains a list of Event Triggers used by the
Event Handling System (EHS)."
::= { tmnxEhsObjs 6 }
tmnxEhsTriggerEntry OBJECT-TYPE
SYNTAX TmnxEhsTriggerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines a row in the tmnxEhsTriggerTable. Each row
contains information about a specific Event Handling
system (EHS) Event Trigger.
Rows are created and deleted via SNMP SET operations using
tmnxEhsTriggerRowStatus."
INDEX {
tmnxEventAppIndex,
tmnxEventID
}
::= { tmnxEhsTriggerTable 1 }
TmnxEhsTriggerEntry ::= SEQUENCE
{
tmnxEhsTriggerRowStatus RowStatus,
tmnxEhsTriggerDescription TItemDescription,
tmnxEhsTriggerLastChange TimeStamp,
tmnxEhsTriggerAdminStatus TmnxAdminState,
tmnxEhsTriggerOperStatus TmnxOperState
}
tmnxEhsTriggerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsTriggerRowStatus specifies
the row status. It allows rows to be created
and deleted in the tmnxEhsTriggerTable.
If any associated rows exist in the tmnxEhsTEntryTable, 'destroy' will
fail with an 'inconsistentValue' error. All associated rows in the
tmnxEhsTEntryTable must be destroyed first."
REFERENCE
"See definition of RowStatus in RFC 2579, 'Textual
Conventions for SMIv2.'"
::= { tmnxEhsTriggerEntry 1 }
tmnxEhsTriggerDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsTriggerDescription specifies a user provided
description string for an EHS Event Trigger. It can consist of any
printable, seven-bit ASCII characters up to 80 characters in length."
DEFVAL { ''H }
::= { tmnxEhsTriggerEntry 2 }
tmnxEhsTriggerLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTriggerLastChange indicates the time this row was
last changed."
::= { tmnxEhsTriggerEntry 3 }
tmnxEhsTriggerAdminStatus OBJECT-TYPE
SYNTAX TmnxAdminState
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsTriggerAdminStatus specifies the administrative
state of the EHS Event Trigger."
DEFVAL { outOfService }
::= { tmnxEhsTriggerEntry 4 }
tmnxEhsTriggerOperStatus OBJECT-TYPE
SYNTAX TmnxOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTriggerOperStatus indicates the operational state
of the EHS Event Trigger."
::= { tmnxEhsTriggerEntry 5 }
tmnxEhsTriggerStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxEhsTriggerStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxEhsTriggerStatsTable contains operational data for Event
Triggers used by the Event Handling System (EHS)."
::= { tmnxEhsObjs 7 }
tmnxEhsTriggerStatsEntry OBJECT-TYPE
SYNTAX TmnxEhsTriggerStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines a row in the tmnxEhsTriggerStatsTable. Each row contains
operational information about a specific EHS Event Trigger.
Rows are created and deleted by the system as rows are created and
deleted in the tmnxEhsTriggerTable."
AUGMENTS { tmnxEhsTriggerEntry }
::= { tmnxEhsTriggerStatsTable 1 }
TmnxEhsTriggerStatsEntry ::= SEQUENCE
{
tmnxEhsTriggerStatsSuccess Unsigned32,
tmnxEhsTriggerStatsErrNoEntry Unsigned32,
tmnxEhsTriggerStatsErrAdmStatus Unsigned32
}
tmnxEhsTriggerStatsSuccess OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTriggerStatsSuccess indicates the number of not
ignored logger event occurrences associated with EHS trigger."
::= { tmnxEhsTriggerStatsEntry 1 }
tmnxEhsTriggerStatsErrNoEntry OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTriggerStatsErrNoEntry indicates the number of
ignored logger event occurrences associated with EHS trigger. Event is
ignored due to no trigger entry configured for this trigger."
::= { tmnxEhsTriggerStatsEntry 2 }
tmnxEhsTriggerStatsErrAdmStatus OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTriggerStatsErrAdmStatus indicates the number of
ignored logger event occurrences associated with EHS trigger. Event is
ignored due to admin state of the trigger.
The trigger may be out-of-service due to tmnxEhsTriggerAdminStatus
being set to 'outOfService (3)'."
::= { tmnxEhsTriggerStatsEntry 3 }
tmnxEhsTEntryTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxEhsTEntryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxEhsTEntryTable contains a list of Event Trigger Entries in an
EHS Event Trigger."
::= { tmnxEhsObjs 8 }
tmnxEhsTEntryEntry OBJECT-TYPE
SYNTAX TmnxEhsTEntryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines a row in the tmnxEhsTEntryTable. Each row
contains information about a specific EHS Event Trigger
Entry.
Rows are created and deleted via SNMP SET operations using
tmnxEhsTEntryRowStatus."
INDEX {
tmnxEventAppIndex,
tmnxEventID,
tmnxEhsTEntryId
}
::= { tmnxEhsTEntryTable 1 }
TmnxEhsTEntryEntry ::= SEQUENCE
{
tmnxEhsTEntryId Unsigned32,
tmnxEhsTEntryRowStatus RowStatus,
tmnxEhsTEntryDescription TItemDescription,
tmnxEhsTEntryLastChange TimeStamp,
tmnxEhsTEntryAdminStatus TmnxAdminState,
tmnxEhsTEntryOperStatus TmnxOperState,
tmnxEhsTEntryLogFilterId TmnxLogFilterId,
tmnxEhsTEntryHandlerName TNamedItemOrEmpty,
tmnxEhsTEntryDebounceVal Unsigned32,
tmnxEhsTEntryDebounceTime Unsigned32
}
tmnxEhsTEntryId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryId specifies the index of a Trigger Entry in
the EHS Event Trigger indicated by the value of tmnxEventAppIndex and
tmnxEventID."
::= { tmnxEhsTEntryEntry 1 }
tmnxEhsTEntryRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryRowStatus specifies
the row status. It allows entries to be created
and deleted in the tmnxEhsTEntryTable.
If an associated row does not exist in the tmnxEhsTriggerTable, an
attempt to create this row entry will fail."
REFERENCE
"See definition of RowStatus in RFC 2579, 'Textual
Conventions for SMIv2.'"
::= { tmnxEhsTEntryEntry 2 }
tmnxEhsTEntryDescription OBJECT-TYPE
SYNTAX TItemDescription
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryDescription specifies a user provided
description string for EHS Event Trigger Entry. It can consist of any
printable, seven-bit ASCII characters up to 80 characters in length."
DEFVAL { ''H }
::= { tmnxEhsTEntryEntry 3 }
tmnxEhsTEntryLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryLastChange indicates the time this row entry
was last changed."
::= { tmnxEhsTEntryEntry 4 }
tmnxEhsTEntryAdminStatus OBJECT-TYPE
SYNTAX TmnxAdminState
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryAdminStatus specifies the administrative
state of the EHS Event Trigger Entry."
DEFVAL { inService }
::= { tmnxEhsTEntryEntry 5 }
tmnxEhsTEntryOperStatus OBJECT-TYPE
SYNTAX TmnxOperState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryOperStatus indicates the operational state
of the EHS Event Trigger Entry."
::= { tmnxEhsTEntryEntry 6 }
tmnxEhsTEntryLogFilterId OBJECT-TYPE
SYNTAX TmnxLogFilterId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryLogFilterId specifies the logger filter
to apply to a generated logger event. If the logger filter match
succeeds, the actions indicated in the associated EHS Event Handler,
indicated by the value of tmnxEhsTEntryHandlerName, are applied.
A value of 0 indicates there is no associated logger filter and
therefore the associated EHS Event Handler is always applied."
DEFVAL { 0 }
::= { tmnxEhsTEntryEntry 7 }
tmnxEhsTEntryHandlerName OBJECT-TYPE
SYNTAX TNamedItemOrEmpty
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryHandlerName specifies the EHS Event Handler
to be applied. The zero-length string may be used to point to a
non-existing Event Handler."
DEFVAL { ''H }
::= { tmnxEhsTEntryEntry 8 }
tmnxEhsTEntryDebounceVal OBJECT-TYPE
SYNTAX Unsigned32 (0 | 2..15)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryDebounceVal specifies the number of times an
event has to occur within a specific time window given by
tmnxEhsTEntryDebounceTime for EHS Event to trigger a response."
DEFVAL { 0 }
::= { tmnxEhsTEntryEntry 9 }
tmnxEhsTEntryDebounceTime OBJECT-TYPE
SYNTAX Unsigned32 (0..604800)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryDebounceTime specifies the time window
within which a specific event must occur more than the value specified
by tmnxEhsTEntryDebounceVal for EHS to trigger a response."
DEFVAL { 0 }
::= { tmnxEhsTEntryEntry 10 }
tmnxEhsTEntryStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxEhsTEntryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Nokia SROS series tmnxEhsTEntryStatsTable contains operational
data for Event Trigger Entries used by an EHS Event Trigger."
::= { tmnxEhsObjs 9 }
tmnxEhsTEntryStatsEntry OBJECT-TYPE
SYNTAX TmnxEhsTEntryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines a row in the tmnxEhsTEntryStatsTable. Each row contains
operational information about a specific EHS Event Trigger Entry.
Rows are created and deleted by the system as row are created and
deleted in the tmnxEhsTEntryTable."
AUGMENTS { tmnxEhsTEntryEntry }
::= { tmnxEhsTEntryStatsTable 1 }
TmnxEhsTEntryStatsEntry ::= SEQUENCE
{
tmnxEhsTEntryStatsFilterMatch Unsigned32,
tmnxEhsTEntryStatsFilterFail Unsigned32,
tmnxEhsTEntryStatsErrAdminStatus Unsigned32,
tmnxEhsTEntryStatsErrFilter Unsigned32,
tmnxEhsTEntryStatsErrHandler Unsigned32,
tmnxEhsTEntryStatsTriggerCount Unsigned32,
tmnxEhsTEntryStatsDebounce Unsigned32
}
tmnxEhsTEntryStatsFilterMatch OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryStatsFilterMatch indicates the number of
times a filter, for the specified trigger entry, matches an logger
event."
::= { tmnxEhsTEntryStatsEntry 1 }
tmnxEhsTEntryStatsFilterFail OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryStatsFilterFail indicates the number of
times a filter, for the specified trigger entry, does not match an
logger event."
::= { tmnxEhsTEntryStatsEntry 2 }
tmnxEhsTEntryStatsErrAdminStatus OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryStatsErrAdminStatus indicates the number of
times the logger event will be ignored due to admin state of EHS
trigger entry.
The trigger entry may be out-of-service due to
tmnxEhsTEntryAdminStatus being set to 'outOfService (3)'."
::= { tmnxEhsTEntryStatsEntry 3 }
tmnxEhsTEntryStatsErrFilter OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryStatsErrFilter indicates the number of times
the logger event will be ignored due to filter is not operational or
is not configured in EHS trigger entry."
::= { tmnxEhsTEntryStatsEntry 4 }
tmnxEhsTEntryStatsErrHandler OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryStatsErrHandler indicates the number of
times the logger event will be ignored due to filter is not
operational or is not configured in EHS trigger entry."
::= { tmnxEhsTEntryStatsEntry 5 }
tmnxEhsTEntryStatsTriggerCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxEhsTEntryStatsTriggerCount indicates the number of
times script execution is triggered after filter match."
::= { tmnxEhsTEntryStatsEntry 6 }
tmnxEhsTEntryStatsDebounce OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the tmnxEhsTEntryStatsDebounce indicates the number of
times script is not executed due to debounce rule."
::= { tmnxEhsTEntryStatsEntry 7 }
tmnxLogCliSubscrTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogCliSubscrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tmnxLogCliSubscrTable contains information about CLI user session
subscriptions to logs."
::= { tmnxLogObjs 30 }
tmnxLogCliSubscrEntry OBJECT-TYPE
SYNTAX TmnxLogCliSubscrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each conceptual row represents information about a subscription of a
particular CLI user session to a particular log.
Entries in this table are created and destroyed automatically by the
system."
INDEX {
tmnxLogCliSubscrSession,
tmnxLogCliSubscrLog
}
::= { tmnxLogCliSubscrTable 1 }
TmnxLogCliSubscrEntry ::= SEQUENCE
{
tmnxLogCliSubscrSession Unsigned32,
tmnxLogCliSubscrLog TmnxLogIdIndex,
tmnxLogCliSubscrType INTEGER,
tmnxLogCliSubscrUser TNamedItem,
tmnxLogCliSubscrUserLoginTime DateAndTime,
tmnxLogCliSubscrUserIpAddrType InetAddressType,
tmnxLogCliSubscrUserIpAddr InetAddress
}
tmnxLogCliSubscrSession OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of the object tmnxLogCliSubscrSession indicates the unique
identifier of a CLI user session."
::= { tmnxLogCliSubscrEntry 1 }
tmnxLogCliSubscrLog OBJECT-TYPE
SYNTAX TmnxLogIdIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxLogCliSubscrLog indicates the unique identifier of an
event stream log.
It refers to a conceptual row in the tmnxLogIdTable."
::= { tmnxLogCliSubscrEntry 2 }
tmnxLogCliSubscrType OBJECT-TYPE
SYNTAX INTEGER {
telnet (1),
console (2),
ssh (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the object tmnxLogCliSubscrType indicates the type of
session."
::= { tmnxLogCliSubscrEntry 3 }
tmnxLogCliSubscrUser OBJECT-TYPE
SYNTAX TNamedItem
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the object tmnxLogCliSubscrUser indicates the name of the
user associated with the CLI session."
::= { tmnxLogCliSubscrEntry 4 }
tmnxLogCliSubscrUserLoginTime OBJECT-TYPE
SYNTAX DateAndTime (SIZE (11))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogCliSubscrUserLoginTime indicates the time the user
logged in."
::= { tmnxLogCliSubscrEntry 5 }
tmnxLogCliSubscrUserIpAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogCliSubscrUserIpAddrType indicates the address type
of tmnxLogCliSubscrUserIpAddr."
::= { tmnxLogCliSubscrEntry 6 }
tmnxLogCliSubscrUserIpAddr OBJECT-TYPE
SYNTAX InetAddress (SIZE (0|4|16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the object tmnxLogCliSubscrUserIpAddr indicates
the IP address of the user."
::= { tmnxLogCliSubscrEntry 7 }
tmnxLogApCustRecordPolicerTable OBJECT-TYPE
SYNTAX SEQUENCE OF TmnxLogApCustRecordPolicerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Nokia SROS series tmnxLogApCustRecordPolicerTable allows to create
custom record policer information for a given accounting policy. Rows
can only be created for existing accounting policies (as defined in
tmnxLogApTable)."
::= { tmnxLogObjs 31 }
tmnxLogApCustRecordPolicerEntry OBJECT-TYPE
SYNTAX TmnxLogApCustRecordPolicerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row contains the specification of the counters that must
be collected for a particular policer and accounting policy.
A conceptual row can be created and destroyed by means of the
tmnxLogApCrPolicerRowStatus object."
INDEX {
tmnxLogApPolicyId,
tmnxLogApCrPolicerId
}
::= { tmnxLogApCustRecordPolicerTable 1 }
TmnxLogApCustRecordPolicerEntry ::= SEQUENCE
{
tmnxLogApCrPolicerId Unsigned32,
tmnxLogApCrPolicerLastChanged TimeStamp,
tmnxLogApCrPolicerRowStatus RowStatus,
tmnxLogApCrPolicerICounters TmnxAccPlcyPolicerICounters,
tmnxLogApCrPolicerECounters TmnxAccPlcyPolicerECounters
}
tmnxLogApCrPolicerId OBJECT-TYPE
SYNTAX Unsigned32 (1..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of tmnxLogApCrPolicerId specifies the policer ID for which
counters will be collected in this custom record.
The counters that will be collected are defined in
tmnxLogApCrPolicerICounters and tmnxLogApCrPolicerECounters."
::= { tmnxLogApCustRecordPolicerEntry 1 }
tmnxLogApCrPolicerLastChanged OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of tmnxLogApCrPolicerLastChanged indicates the sysUpTime
when an object in this table was last modified.
A value of zero means that no change was made to this row since it was
created."
::= { tmnxLogApCustRecordPolicerEntry 2 }
tmnxLogApCrPolicerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row Status of the entry. This allows creation/deletion of rows in this
table."
::= { tmnxLogApCustRecordPolicerEntry 3 }
tmnxLogApCrPolicerICounters OBJECT-TYPE
SYNTAX TmnxAccPlcyPolicerICounters
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogApCrPolicerICounters specifies the list of ingress
counters that need to be collected in this custom record."
DEFVAL { {} }
::= { tmnxLogApCustRecordPolicerEntry 4 }
tmnxLogApCrPolicerECounters OBJECT-TYPE
SYNTAX TmnxAccPlcyPolicerECounters
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of tmnxLogApCrPolicerECounters specifies the list of egress
counters that need to be collected in this custom record."
DEFVAL { {} }
::= { tmnxLogApCustRecordPolicerEntry 5 }
tmnxLogConformance OBJECT IDENTIFIER ::= { tmnxSRConfs 12 }
tmnxLogCompliances OBJECT IDENTIFIER ::= { tmnxLogConformance 1 }
tmnxLogV4v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 4.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV4v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogFileIdGroup,
tmnxLogSyslogGroup,
tmnxSnmpTrapGroup,
tmnxLogEventsR2r1Group,
tmnxLogNotificationR3r0Group
}
::= { tmnxLogCompliances 4 }
tmnxLogV5v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 5.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogNotificationV5v0Group
}
::= { tmnxLogCompliances 5 }
tmnxLogV6v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 6.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpTrapDestV6v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogNotificationV6v0Group
}
::= { tmnxLogCompliances 6 }
tmnxLogV6v1Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 6.1 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpTrapDestV6v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogNotificationV6v0Group,
tmnxLogAccountingPolicyV6v1Group
}
::= { tmnxLogCompliances 7 }
tmnxLogV7v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 7.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpTrapDestV6v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogNotificationV6v0Group,
tmnxLogAccountingPolicyV6v1Group,
tmnxLogAccountingPolicyCRV7v0Group,
tmnxLogRoutePreferenceV7v0Group
}
::= { tmnxLogCompliances 8 }
tmnxLogV9v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 9.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogAccountingPolicyV6v1Group,
tmnxLogAccountingPolicyCRV7v0Group,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpTrapDestV6v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogNotificationV6v0Group,
tmnxLogNotificationV9v0Group,
tmnxLogRoutePreferenceV7v0Group,
tmnxLogEventDampedV8v0Group,
tmnxLogApV9v0Group
}
::= { tmnxLogCompliances 9 }
tmnxLogV8v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 7.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpTrapDestV6v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogNotificationV6v0Group,
tmnxLogAccountingPolicyV6v1Group,
tmnxLogAccountingPolicyCRV7v0Group,
tmnxLogRoutePreferenceV7v0Group,
tmnxLogEventDampedV8v0Group
}
::= { tmnxLogCompliances 10 }
tmnxLogV10v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 10.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogAccountingPolicyV6v1Group,
tmnxLogAccountingPolicyCRV7v0Group,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpTrapDestV6v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogNotificationV6v0Group,
tmnxLogNotificationV9v0Group,
tmnxLogRoutePreferenceV7v0Group,
tmnxLogEventDampedV8v0Group,
tmnxLogApV9v0Group,
tmnxLogExRbkOpGroup
}
::= { tmnxLogCompliances 11 }
tmnxLogV11v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 11.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogAccountingPolicyV6v1Group,
tmnxLogAccountingPolicyCRV7v0Group,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpTrapDestV6v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogEventsV11v0Group,
tmnxLogNotificationV6v0Group,
tmnxLogNotificationV9v0Group,
tmnxLogRoutePreferenceV7v0Group,
tmnxLogEventDampedV8v0Group,
tmnxLogApV9v0Group,
tmnxLogExRbkOpGroup,
tmnxLogApExtGroup,
tmnxLogAppRouteNotifV10v0Group,
tmnxLogApV11v0Group,
tmnxLogApCrV11v0Group
}
::= { tmnxLogCompliances 12 }
tmnxLogV13v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 13.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogAccountingPolicyV6v1Group,
tmnxLogAccountingPolicyCRV7v0Group,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpTrapDestV6v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogEventsV11v0Group,
tmnxLogNotificationV6v0Group,
tmnxLogNotificationV9v0Group,
tmnxLogRoutePreferenceV7v0Group,
tmnxLogEventDampedV8v0Group,
tmnxLogApV9v0Group,
tmnxLogExRbkOpGroup,
tmnxLogApExtGroup,
tmnxLogAppRouteNotifV10v0Group,
tmnxLogApV11v0Group,
tmnxLogApCrV11v0Group,
tmnxLogFilterMsgV13v0Group,
tmnxLogEHSV13v0Group
}
::= { tmnxLogCompliances 13 }
tmnxLogV14v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 14.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogEHSV14v0Group
}
::= { tmnxLogCompliances 14 }
tmnxLogV15v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 15.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogAccountingPolicyCRV7v0Group,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpTrapDestV6v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogEventsV11v0Group,
tmnxLogNotificationV6v0Group,
tmnxLogNotificationV9v0Group,
tmnxLogRoutePreferenceV7v0Group,
tmnxLogEventDampedV8v0Group,
tmnxLogApV9v0Group,
tmnxLogExRbkOpGroup,
tmnxLogApExtGroup,
tmnxLogAppRouteNotifV10v0Group,
tmnxLogApV11v0Group,
tmnxLogApCrV11v0Group,
tmnxLogFilterMsgV13v0Group,
tmnxLogEHSV13v0Group,
tmnxLogEHSV14v0Group,
tmnxLogPythonGroup,
tmnxLogToSessionGroup,
tmnxLogToNetconfGroup
}
::= { tmnxLogCompliances 15 }
tmnxLogV16v0Compliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for revision 16.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogAccountingPolicyCRV7v0Group,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpTrapDestV6v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogEventsV11v0Group,
tmnxLogNotificationV6v0Group,
tmnxLogNotificationV9v0Group,
tmnxLogRoutePreferenceV7v0Group,
tmnxLogEventDampedV8v0Group,
tmnxLogApV9v0Group,
tmnxLogExRbkOpGroup,
tmnxLogApExtGroup,
tmnxLogAppRouteNotifV10v0Group,
tmnxLogApV11v0Group,
tmnxLogApCrV11v0Group,
tmnxLogFilterMsgV13v0Group,
tmnxLogEHSV13v0Group,
tmnxLogEHSV14v0Group,
tmnxLogPythonGroup,
tmnxLogToSessionGroup,
tmnxLogToNetconfGroup,
tmnxLogEventsV16v0Group,
tmnxLogCliSubscrGroup
}
::= { tmnxLogCompliances 16 }
tmnxLogV19v0Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for revision 19.0 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogGlobalGroup,
tmnxLogV5v0Group,
tmnxLogAccountingPolicyGroup,
tmnxLogAccountingPolicyCRV7v0Group,
tmnxLogFileIdGroup,
tmnxLogSyslogV5v0Group,
tmnxSnmpTrapV5v0Group,
tmnxSnmpTrapDestV6v0Group,
tmnxSnmpSetErrsGroup,
tmnxLogEventsV5v0Group,
tmnxLogEventsV11v0Group,
tmnxLogNotificationV6v0Group,
tmnxLogNotificationV9v0Group,
tmnxLogRoutePreferenceV7v0Group,
tmnxLogEventDampedV8v0Group,
tmnxLogApV9v0Group,
tmnxLogExRbkOpGroup,
tmnxLogApExtGroup,
tmnxLogAppRouteNotifV10v0Group,
tmnxLogApV11v0Group,
tmnxLogApCrV11v0Group,
tmnxLogFilterMsgV13v0Group,
tmnxLogEHSV13v0Group,
tmnxLogEHSV14v0Group,
tmnxLogPythonGroup,
tmnxLogToSessionGroup,
tmnxLogToNetconfGroup,
tmnxLogEventsV16v0Group,
tmnxLogCliSubscrGroup,
tmnxLogAcctPolicyCrV19v0Group,
tmnxLogApV19v0Group
}
::= { tmnxLogCompliances 17 }
tmnxLogV20v0Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for revision 20 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxLogNameGroup,
tmnxLogFilterNameGroup,
tmnxLogSnmpTrapGroupNameGroup,
tmnxLogFilterParamsNameGroup,
tmnxSyslogTargetNameGroup
}
::= { tmnxLogCompliances 18 }
tmnxLogV21v0Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for revision 21 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxSyslogTlsClntProfilNameGroup,
tmnxLogFileNameGroup
}
::= { tmnxLogCompliances 19 }
tmnxLogV22v0Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for revision 22 of TIMETRA-LOG-MIB."
MODULE
MANDATORY-GROUPS {
tmnxSnmpTrapDestV22v0Group
}
::= { tmnxLogCompliances 20 }
tmnxLogGroups OBJECT IDENTIFIER ::= { tmnxLogConformance 2 }
tmnxLogGlobalGroup OBJECT-GROUP
OBJECTS {
tmnxLogMaxLogs
}
STATUS current
DESCRIPTION
"The group of objects supporting management of event logging
capabilities on Nokia SROS series systems."
::= { tmnxLogGroups 1 }
tmnxLogAccountingPolicyGroup OBJECT-GROUP
OBJECTS {
tmnxLogApRowStatus,
tmnxLogApStorageType,
tmnxLogApAdminStatus,
tmnxLogApOperStatus,
tmnxLogApInterval,
tmnxLogApDescription,
tmnxLogApDefault,
tmnxLogApRecord,
tmnxLogApToFileId,
tmnxLogApPortType,
tmnxLogApAlign
}
STATUS current
DESCRIPTION
"The group of objects supporting management of accounting policies
capabilities on Nokia SROS series systems."
::= { tmnxLogGroups 3 }
tmnxLogFileIdGroup OBJECT-GROUP
OBJECTS {
tmnxLogFileIdRowStatus,
tmnxLogFileIdStorageType,
tmnxLogFileIdRolloverTime,
tmnxLogFileIdRetainTime,
tmnxLogFileIdAdminLocation,
tmnxLogFileIdOperLocation,
tmnxLogFileIdDescription,
tmnxLogFileIdLogType,
tmnxLogFileIdLogId,
tmnxLogFileIdPathName,
tmnxLogFileIdCreateTime,
tmnxLogFileIdBackupLoc
}
STATUS current
DESCRIPTION
"The group of objects supporting management of Log File destinations on
Nokia SROS series systems."
::= { tmnxLogGroups 4 }
tmnxLogSyslogGroup OBJECT-GROUP
OBJECTS {
tmnxSyslogTargetRowStatus,
tmnxSyslogTargetDescription,
tmnxSyslogTargetAddress,
tmnxSyslogTargetUdpPort,
tmnxSyslogTargetFacility,
tmnxSyslogTargetSeverity,
tmnxSyslogTargetMessagePrefix,
tmnxSyslogTargetMessagesDropped
}
STATUS obsolete
DESCRIPTION
"The group of objects supporting management of Log Syslog destinations
on Nokia SROS series systems."
::= { tmnxLogGroups 5 }
tmnxSnmpTrapGroup OBJECT-GROUP
OBJECTS {
tmnxStgRowStatus,
tmnxStgDescription,
tmnxStgVersion,
tmnxStgNotifyCommunity,
tmnxStgSecurityLevel
}
STATUS obsolete
DESCRIPTION
"The group of objects supporting management of Log SNMP notification
destinations on Nokia SROS series systems."
::= { tmnxLogGroups 6 }
tmnxLogEventsR2r1Group OBJECT-GROUP
OBJECTS {
tmnxEventAppName,
tmnxEventName,
tmnxEventSeverity,
tmnxEventControl,
tmnxEventCounter,
tmnxEventDropCount,
tmnxEventReset,
tmnxEventTest
}
STATUS obsolete
DESCRIPTION
"The group of objects supporting management of Log Events on Nokia SROS
series systems release 2.1."
::= { tmnxLogGroups 10 }
tmnxLogNotifyObjsR3r0Group OBJECT-GROUP
OBJECTS {
tmnxLogFileDeletedLogId,
tmnxLogFileDeletedFileId,
tmnxLogFileDeletedLogType,
tmnxLogFileDeletedLocation,
tmnxLogFileDeletedName,
tmnxLogFileDeletedCreateTime,
tmnxLogTraceErrorTitle,
tmnxLogTraceErrorMessage
}
STATUS obsolete
DESCRIPTION
"The group of objects supporting management of Log notifications on
Nokia SROS series systems."
::= { tmnxLogGroups 13 }
tmnxLogNotificationR3r0Group NOTIFICATION-GROUP
NOTIFICATIONS {
tmnxLogSpaceContention,
tmnxLogAdminLocFailed,
tmnxLogBackupLocFailed,
tmnxLogFileRollover,
tmnxLogFileDeleted,
tmnxTestEvent,
tmnxLogTraceError
}
STATUS obsolete
DESCRIPTION
"The group of notifications supporting the Log feature on Nokia SROS
series systems release 3.0."
::= { tmnxLogGroups 14 }
tmnxLogV4v0Group OBJECT-GROUP
OBJECTS {
tmnxLogIdRowStatus,
tmnxLogIdStorageType,
tmnxLogIdAdminStatus,
tmnxLogIdOperStatus,
tmnxLogIdDescription,
tmnxLogIdFilterId,
tmnxLogIdSource,
tmnxLogIdDestination,
tmnxLogIdFileId,
tmnxLogIdSyslogId,
tmnxLogIdMaxMemorySize,
tmnxLogIdConsoleSession,
tmnxLogIdForwarded,
tmnxLogIdDropped,
tmnxLogIdTimeFormat,
tmnxLogFilterRowStatus,
tmnxLogFilterDescription,
tmnxLogFilterDefaultAction,
tmnxLogFilterInUse,
tmnxLogFilterParamsRowStatus,
tmnxLogFilterParamsDescription,
tmnxLogFilterParamsAction,
tmnxLogFilterParamsApplication,
tmnxLogFilterParamsApplOperator,
tmnxLogFilterParamsNumber,
tmnxLogFilterParamsNumberOperator,
tmnxLogFilterParamsSeverity,
tmnxLogFilterParamsSeverityOperator,
tmnxLogFilterParamsSubject,
tmnxLogFilterParamsSubjectOperator,
tmnxLogFilterParamsSubjectRegexp
}
STATUS obsolete
DESCRIPTION
"The group of objects supporting management of event logs on Nokia SROS
series systems."
::= { tmnxLogGroups 15 }
tmnxSnmpSetErrsGroup OBJECT-GROUP
OBJECTS {
tmnxSnmpSetErrsMax,
tmnxSseVersion,
tmnxSseSeverityLevel,
tmnxSseModuleId,
tmnxSseModuleName,
tmnxSseErrorCode,
tmnxSseErrorName,
tmnxSseErrorMsg,
tmnxSseExtraText,
tmnxSseTimestamp
}
STATUS current
DESCRIPTION
"The group of objects supporting management of SNMP SET failure error
messages."
::= { tmnxLogGroups 16 }
tmnxLogEventsV5v0Group OBJECT-GROUP
OBJECTS {
tmnxEventAppName,
tmnxEventName,
tmnxEventSeverity,
tmnxEventControl,
tmnxEventCounter,
tmnxEventDropCount,
tmnxEventReset,
tmnxEventThrottle,
tmnxEventTest,
tmnxEventThrottleLimit,
tmnxEventThrottleInterval
}
STATUS current
DESCRIPTION
"The group of objects supporting management of Log Events on Nokia SROS
series systems release 5.0."
::= { tmnxLogGroups 17 }
tmnxLogNotifyObjsV5v0Group OBJECT-GROUP
OBJECTS {
tmnxLogFileDeletedLogId,
tmnxLogFileDeletedFileId,
tmnxLogFileDeletedLogType,
tmnxLogFileDeletedLocation,
tmnxLogFileDeletedName,
tmnxLogFileDeletedCreateTime,
tmnxLogTraceErrorTitle,
tmnxLogTraceErrorMessage,
tmnxLogThrottledEventID,
tmnxLogThrottledEvents,
tmnxSysLogTargetId,
tmnxSysLogTargetProblemDescr
}
STATUS obsolete
DESCRIPTION
"The group of objects supporting management of Log notifications on
Nokia SROS series systems release 5.0."
::= { tmnxLogGroups 18 }
tmnxLogNotificationV5v0Group NOTIFICATION-GROUP
NOTIFICATIONS {
tmnxLogSpaceContention,
tmnxLogAdminLocFailed,
tmnxLogBackupLocFailed,
tmnxLogFileRollover,
tmnxLogFileDeleted,
tmnxTestEvent,
tmnxLogTraceError,
tmnxLogEventThrottled,
tmnxSysLogTargetProblem
}
STATUS obsolete
DESCRIPTION
"The group of notifications supporting the Log feature on Nokia SROS
series systems release 5.0."
::= { tmnxLogGroups 19 }
tmnxLogSyslogV5v0Group OBJECT-GROUP
OBJECTS {
tmnxSyslogTargetRowStatus,
tmnxSyslogTargetDescription,
tmnxSyslogTargetUdpPort,
tmnxSyslogTargetFacility,
tmnxSyslogTargetSeverity,
tmnxSyslogTargetMessagePrefix,
tmnxSyslogTargetMessagesDropped,
tmnxSyslogTargetAddrType,
tmnxSyslogTargetAddr
}
STATUS current
DESCRIPTION
"The group of objects supporting management of Log Syslog destinations
on Nokia SROS series systems release 5.0."
::= { tmnxLogGroups 20 }
tmnxSnmpTrapV5v0Group OBJECT-GROUP
OBJECTS {
tmnxSnmpTrapLogDescription,
tmnxStdRowStatus,
tmnxStdRowLastChanged,
tmnxStdDestAddrType,
tmnxStdDestAddr,
tmnxStdDestPort,
tmnxStdDescription,
tmnxStdVersion,
tmnxStdNotifyCommunity,
tmnxStdSecurityLevel,
tmnxStdMaxTargets
}
STATUS current
DESCRIPTION
"The group of objects supporting management of Log SNMP notification
destinations on Nokia SROS series systems for release 5.0."
::= { tmnxLogGroups 21 }
tmnxLogV5v0Group OBJECT-GROUP
OBJECTS {
tmnxLogIdRowStatus,
tmnxLogIdStorageType,
tmnxLogIdAdminStatus,
tmnxLogIdOperStatus,
tmnxLogIdDescription,
tmnxLogIdFilterId,
tmnxLogIdSource,
tmnxLogIdDestination,
tmnxLogIdFileId,
tmnxLogIdSyslogId,
tmnxLogIdMaxMemorySize,
tmnxLogIdConsoleSession,
tmnxLogIdForwarded,
tmnxLogIdDropped,
tmnxLogIdTimeFormat,
tmnxLogFilterRowStatus,
tmnxLogFilterDescription,
tmnxLogFilterDefaultAction,
tmnxLogFilterInUse,
tmnxLogFilterParamsRowStatus,
tmnxLogFilterParamsDescription,
tmnxLogFilterParamsAction,
tmnxLogFilterParamsApplication,
tmnxLogFilterParamsApplOperator,
tmnxLogFilterParamsNumber,
tmnxLogFilterParamsNumberOperator,
tmnxLogFilterParamsSeverity,
tmnxLogFilterParamsSeverityOperator,
tmnxLogFilterParamsSubject,
tmnxLogFilterParamsSubjectOperator,
tmnxLogFilterParamsSubjectRegexp,
tmnxLogFilterParamsRouter,
tmnxLogFilterParamsRouterOperator,
tmnxLogFilterParamsRouterRegexp
}
STATUS current
DESCRIPTION
"The group of objects supporting management of event logs on Nokia SROS
series systems in release 5.0."
::= { tmnxLogGroups 22 }
tmnxLogObsoleteObjsV5v0Group OBJECT-GROUP
OBJECTS {
tmnxSyslogTargetAddress,
tmnxStgRowStatus,
tmnxStgDescription,
tmnxStgVersion,
tmnxStgNotifyCommunity,
tmnxStgSecurityLevel
}
STATUS current
DESCRIPTION
"The group of objects supporting management of TiMOS logs obsoleted on
Nokia SROS series systems in release 5.0."
::= { tmnxLogGroups 23 }
tmnxLogNotifyObjsV6v0Group OBJECT-GROUP
OBJECTS {
tmnxLogFileDeletedLogId,
tmnxLogFileDeletedFileId,
tmnxLogFileDeletedLogType,
tmnxLogFileDeletedLocation,
tmnxLogFileDeletedName,
tmnxLogFileDeletedCreateTime,
tmnxLogTraceErrorTitle,
tmnxLogTraceErrorMessage,
tmnxLogThrottledEventID,
tmnxLogThrottledEvents,
tmnxSysLogTargetId,
tmnxSysLogTargetProblemDescr,
tmnxLogNotifyApInterval,
tmnxStdReplayStartEvent,
tmnxStdReplayEndEvent
}
STATUS obsolete
DESCRIPTION
"The group of objects supporting management of Log notifications on
Nokia SROS series systems release 6.0."
::= { tmnxLogGroups 24 }
tmnxLogNotificationV6v0Group NOTIFICATION-GROUP
NOTIFICATIONS {
tmnxLogSpaceContention,
tmnxLogAdminLocFailed,
tmnxLogBackupLocFailed,
tmnxLogFileRollover,
tmnxLogFileDeleted,
tmnxTestEvent,
tmnxLogTraceError,
tmnxLogEventThrottled,
tmnxSysLogTargetProblem,
tmnxLogAccountingDataLoss,
tmnxStdEventsReplayed
}
STATUS current
DESCRIPTION
"The group of notifications supporting the Log feature on Nokia SROS
series systems release 6.0."
::= { tmnxLogGroups 25 }
tmnxSnmpTrapDestV6v0Group OBJECT-GROUP
OBJECTS {
tmnxStdReplay,
tmnxStdReplayStart,
tmnxStdReplayLastTime
}
STATUS current
DESCRIPTION
"The group of objects added to support SNMP trap destinations in the
Nokia SROS series systems release 6.0."
::= { tmnxLogGroups 26 }
tmnxLogAccountingPolicyV6v1Group OBJECT-GROUP
OBJECTS {
tmnxLogApDefaultInterval
}
STATUS obsolete
DESCRIPTION
"The group of objects supporting management of accounting policies
capabilities on Nokia SROS series systems release 6.1."
::= { tmnxLogGroups 27 }
tmnxLogAccountingPolicyCRV7v0Group OBJECT-GROUP
OBJECTS {
tmnxLogApCrLastChanged,
tmnxLogApCrSignChangeDelta,
tmnxLogApCrSignChangeQueue,
tmnxLogApCrSignChangeQICounters,
tmnxLogApCrSignChangeQECounters,
tmnxLogApCrSignChangeAACounters,
tmnxLogApCrAACounters,
tmnxLogApCrQueueRowStatus,
tmnxLogApCrQueueLastChanged,
tmnxLogApCrQueueICounters,
tmnxLogApCrQueueECounters
}
STATUS current
DESCRIPTION
"The group of objects supporting the creation of a custom record inside
a accounting policy on Nokia SROS series systems."
::= { tmnxLogGroups 28 }
tmnxLogRoutePreferenceV7v0Group OBJECT-GROUP
OBJECTS {
tmnxEventPrimaryRoutePref,
tmnxEventSecondaryRoutePref
}
STATUS current
DESCRIPTION
"The group of objects supporting routing preferences of Log Events on
Nokia SROS series systems release 7.0."
::= { tmnxLogGroups 29 }
tmnxLogNotifyObjsV8v0Group OBJECT-GROUP
OBJECTS {
tmnxLogFileDeletedLogId,
tmnxLogFileDeletedFileId,
tmnxLogFileDeletedLogType,
tmnxLogFileDeletedLocation,
tmnxLogFileDeletedName,
tmnxLogFileDeletedCreateTime,
tmnxLogTraceErrorTitle,
tmnxLogTraceErrorSubject,
tmnxLogTraceErrorMessage,
tmnxLogThrottledEventID,
tmnxLogThrottledEvents,
tmnxSysLogTargetId,
tmnxSysLogTargetProblemDescr,
tmnxLogNotifyApInterval,
tmnxStdReplayStartEvent,
tmnxStdReplayEndEvent
}
STATUS current
DESCRIPTION
"The group of objects supporting management of Log notifications on
Nokia SROS series systems release 8.0."
::= { tmnxLogGroups 30 }
tmnxLogNotificationV9v0Group NOTIFICATION-GROUP
NOTIFICATIONS {
tmnxLogEventOverrun
}
STATUS current
DESCRIPTION
"The group of notifications supporting the Log feature on Nokia SROS
series systems added in release 9.0."
::= { tmnxLogGroups 31 }
tmnxLogEventDampedV8v0Group OBJECT-GROUP
OBJECTS {
tmnxLogConfigEventsDamped
}
STATUS current
DESCRIPTION
"The group of objects supporting damping of change events on Nokia SROS
series systems added in release 8.0r7."
::= { tmnxLogGroups 32 }
tmnxLogApV9v0Group OBJECT-GROUP
OBJECTS {
tmnxLogApDataLossCount,
tmnxLogApLastDataLossTimeStamp
}
STATUS current
DESCRIPTION
"The group of objects extending the application log table on Nokia SROS
series systems added in release 9.0."
::= { tmnxLogGroups 33 }
tmnxLogExRbkOpGroup OBJECT-GROUP
OBJECTS {
tmnxLogExRbkOpTblLastChange,
tmnxLogExRbkOpMaxEntries,
tmnxLogExRbkOpLastChanged,
tmnxLogExRbkOpType,
tmnxLogExRbkOpStatus,
tmnxLogExRbkOpBegin,
tmnxLogExRbkOpEnd,
tmnxLogExRbkOpFile,
tmnxLogExRbkOpUser,
tmnxLogExRbkOpNumEvents,
tmnxLogExRbkEventOID
}
STATUS current
DESCRIPTION
"The group of objects managing exec and rollback revert event history."
::= { tmnxLogGroups 34 }
tmnxLogNotifyObjsV10v0Group OBJECT-GROUP
OBJECTS {
tmnxLogExecRollbackOpIndex
}
STATUS current
DESCRIPTION
"The group of accessible-for-notify objects added to Nokia SROS series
systems release 10.0."
::= { tmnxLogGroups 35 }
tmnxLogApExtGroup OBJECT-GROUP
OBJECTS {
tmnxLogApToFileType
}
STATUS current
DESCRIPTION
"The group of objects extending the accounting policy table on Nokia
SROS series systems."
::= { tmnxLogGroups 36 }
tmnxLogAppRouteNotifV10v0Group OBJECT-GROUP
OBJECTS {
tmnxLogColdStartWaitTime,
tmnxLogRouteRecoveryWaitTime
}
STATUS current
DESCRIPTION
"The group of objects supporting notifications on completion of wait
time after cold reboot and route recovery on Nokia SROS series systems
release 10.0."
::= { tmnxLogGroups 37 }
tmnxLogApV11v0Group OBJECT-GROUP
OBJECTS {
tmnxLogApIncludeSystemInfo
}
STATUS current
DESCRIPTION
"The group of additional objects supporting the Log Accounting Policy
feature on Nokia SROS series systems in release 11.0."
::= { tmnxLogGroups 38 }
tmnxLogEventsV11v0Group OBJECT-GROUP
OBJECTS {
tmnxEventSpecThrottle,
tmnxEventSpecThrottleLimit,
tmnxEventSpecThrottleIntval,
tmnxEventSpecThrottleDef,
tmnxEventSpecThrottleLimitDef,
tmnxEventSpecThrottleIntvalDef
}
STATUS current
DESCRIPTION
"The group of objects supporting management of Log Events added for
Nokia SROS series systems release 11.0."
::= { tmnxLogGroups 40 }
tmnxLogApCrV11v0Group OBJECT-GROUP
OBJECTS {
tmnxLogApCrAASubAttributes
}
STATUS current
DESCRIPTION
"The group of additional objects supporting the Log Accounting Policy
Custom Record feature on Nokia SROS series systems in release 11.0."
::= { tmnxLogGroups 41 }
tmnxLogFilterMsgV13v0Group OBJECT-GROUP
OBJECTS {
tmnxLogFilterParamsMsg,
tmnxLogFilterParamsMsgOperator,
tmnxLogFilterParamsMsgRegexp
}
STATUS current
DESCRIPTION
"The group of objects supporting management of event logs on Nokia SROS
series systems in release 13.0."
::= { tmnxLogGroups 42 }
tmnxLogNotifyObjsV13v0Group OBJECT-GROUP
OBJECTS {
tmnxLogExecRollbackOpType
}
STATUS current
DESCRIPTION
"The group of accessible-for-notify objects added to Nokia SROS series
systems release 13.0."
::= { tmnxLogGroups 43 }
tmnxLogEHSV13v0Group OBJECT-GROUP
OBJECTS {
tmnxEhsHandlerTblLastChange,
tmnxEhsHandlerMaxEntries,
tmnxEhsHandlerRowStatus,
tmnxEhsHandlerDescription,
tmnxEhsHandlerLastChange,
tmnxEhsHandlerAdminStatus,
tmnxEhsHandlerOperStatus,
tmnxEhsHandlerStatsSuccess,
tmnxEhsHandlerStatsErrNoEntry,
tmnxEhsHandlerStatsErrAdmStatus,
tmnxEhsHEntryTblLastChange,
tmnxEhsHEntryMaxEntries,
tmnxEhsHEntryRowStatus,
tmnxEhsHEntryDescription,
tmnxEhsHEntryLastChange,
tmnxEhsHEntryAdminStatus,
tmnxEhsHEntryOperStatus,
tmnxEhsHEntryScriptPlcyName,
tmnxEhsHEntryScriptPlcyOwner,
tmnxEhsHEntryMinDelay,
tmnxEhsHEntryLastExecuted,
tmnxEhsHEntryStatsLaunchSuccess,
tmnxEhsHEntryStatsErrMinDelay,
tmnxEhsHEntryStatsErrLaunch,
tmnxEhsHEntryStatsErrAdmStatus,
tmnxEhsTriggerTblLastChange,
tmnxEhsTriggerMaxEntries,
tmnxEhsTriggerRowStatus,
tmnxEhsTriggerDescription,
tmnxEhsTriggerLastChange,
tmnxEhsTriggerAdminStatus,
tmnxEhsTriggerOperStatus,
tmnxEhsTriggerStatsSuccess,
tmnxEhsTriggerStatsErrNoEntry,
tmnxEhsTriggerStatsErrAdmStatus,
tmnxEhsTEntryTblLastChange,
tmnxEhsTEntryMaxEntries,
tmnxEhsTEntryRowStatus,
tmnxEhsTEntryDescription,
tmnxEhsTEntryLastChange,
tmnxEhsTEntryAdminStatus,
tmnxEhsTEntryOperStatus,
tmnxEhsTEntryLogFilterId,
tmnxEhsTEntryHandlerName,
tmnxEhsTEntryStatsFilterMatch,
tmnxEhsTEntryStatsFilterFail,
tmnxEhsTEntryStatsErrAdminStatus,
tmnxEhsTEntryStatsErrFilter,
tmnxEhsTEntryStatsErrHandler,
tmnxEhsTEntryStatsTriggerCount
}
STATUS current
DESCRIPTION
"The group of objects supporting the Event Handling System (EHS)
feature on Nokia SROS series systems in release 13.0."
::= { tmnxLogGroups 44 }
tmnxLogNotifyObjsV14v0Group OBJECT-GROUP
OBJECTS {
tmnxEhsHEntryMinDelayInterval
}
STATUS current
DESCRIPTION
"The group of accessible-for-notify objects added to Nokia SROS series
systems release 14.0."
::= { tmnxLogGroups 45 }
tmnxLogEHSV14v0Group OBJECT-GROUP
OBJECTS {
tmnxEhsTEntryDebounceVal,
tmnxEhsTEntryDebounceTime,
tmnxEhsTEntryStatsDebounce
}
STATUS current
DESCRIPTION
"The group of objects supporting the Event Handling System (EHS)
feature on Nokia SROS series systems in release 14.0."
::= { tmnxLogGroups 46 }
tmnxLogPythonGroup OBJECT-GROUP
OBJECTS {
tmnxLogIdPythonPolicy
}
STATUS current
DESCRIPTION
"The group of objects supporting Python for log messages on Nokia SROS
series systems."
::= { tmnxLogGroups 50 }
tmnxLogToSessionGroup OBJECT-GROUP
OBJECTS {
tmnxLogIdOperDestination
}
STATUS current
DESCRIPTION
"The group of objects supporting log messages on Nokia SROS series
systems."
::= { tmnxLogGroups 51 }
tmnxLogObsoleteObjsV15v0Group OBJECT-GROUP
OBJECTS {
tmnxLogIdConsoleSession,
tmnxLogApDefaultInterval
}
STATUS current
DESCRIPTION
"The group of objects supporting management of TiMOS logs obsoleted on
Nokia SROS series systems in release 15.0."
::= { tmnxLogGroups 52 }
tmnxLogToNetconfGroup OBJECT-GROUP
OBJECTS {
tmnxLogIdNetconfStream
}
STATUS current
DESCRIPTION
"The group of objects supporting NETCONF log messages on Nokia SROS
series systems."
::= { tmnxLogGroups 53 }
tmnxLogEventsV16v0Group OBJECT-GROUP
OBJECTS {
tmnxEventRepeat
}
STATUS current
DESCRIPTION
"The group of objects supporting management of Log Events added for
Nokia SROS series systems release 16.0."
::= { tmnxLogGroups 54 }
tmnxLogCliSubscrGroup OBJECT-GROUP
OBJECTS {
tmnxLogCliSubscrType,
tmnxLogCliSubscrUser,
tmnxLogCliSubscrUserLoginTime,
tmnxLogCliSubscrUserIpAddrType,
tmnxLogCliSubscrUserIpAddr
}
STATUS current
DESCRIPTION
"The group of objects that support read-only access to CLI users
subscriptions to event log messages on Nokia SROS series systems."
::= { tmnxLogGroups 55 }
tmnxLogAcctPolicyCrV19v0Group OBJECT-GROUP
OBJECTS {
tmnxLogApCrPolicerLastChanged,
tmnxLogApCrPolicerRowStatus,
tmnxLogApCrPolicerICounters,
tmnxLogApCrPolicerECounters,
tmnxLogApCrSignChangePolicer,
tmnxLogApCrSignChangePICounters,
tmnxLogApCrSignChangePECounters
}
STATUS current
DESCRIPTION
"The group of objects supporting custom records inside a accounting
policy on Nokia SROS series systems added in release 19."
::= { tmnxLogGroups 56 }
tmnxLogApV19v0Group OBJECT-GROUP
OBJECTS {
tmnxLogApAlign
}
STATUS current
DESCRIPTION
"The group of additional objects supporting the Log Accounting Policy
feature on Nokia SROS series systems in release 19.0."
::= { tmnxLogGroups 57 }
tmnxLogNameGroup OBJECT-GROUP
OBJECTS {
tmnxLogIdName
}
STATUS current
DESCRIPTION
"The group of additional objects supporting the Log Id Vs Name feature
on Nokia SROS series systems in release 20."
::= { tmnxLogGroups 58 }
tmnxLogFilterNameGroup OBJECT-GROUP
OBJECTS {
tmnxLogFilterName
}
STATUS current
DESCRIPTION
"The group of additional objects supporting the Log Filter Id Vs Name
feature on Nokia SROS series systems in release 20."
::= { tmnxLogGroups 59 }
tmnxLogSnmpTrapGroupNameGroup OBJECT-GROUP
OBJECTS {
snmpNotifyId
}
STATUS current
DESCRIPTION
"The group of additonal objects supporting the Log Snmp-trap-group Id
vs Name feature on Nokia SROS series systems in release 20."
::= { tmnxLogGroups 60 }
tmnxLogFilterParamsNameGroup OBJECT-GROUP
OBJECTS {
tmnxLogFilterParamsName
}
STATUS current
DESCRIPTION
"The group of additonal objects supporting the Log Filter Entry Id vs
Name feature on Nokia SROS series systems in release 20."
::= { tmnxLogGroups 61 }
tmnxSyslogTargetNameGroup OBJECT-GROUP
OBJECTS {
tmnxSyslogTargetName
}
STATUS current
DESCRIPTION
"The group of additonal objects supporting the Log Syslog Id vs Name
feature on Nokia SROS series systems in release 20."
::= { tmnxLogGroups 63 }
tmnxSyslogTlsClntProfilNameGroup OBJECT-GROUP
OBJECTS {
tmnxSyslogTlsClntProfileName
}
STATUS current
DESCRIPTION
"The group of additonal objects supporting the Log Syslog over TLS
feature on Nokia SROS series systems in release 20."
::= { tmnxLogGroups 64 }
tmnxLogApObsoleteObjsV21v0Group OBJECT-GROUP
OBJECTS {
tmnxLogApCrSignChangeOCntr,
tmnxLogApCrSignChangeOECounters,
tmnxLogApCrSignChangeOICounters,
tmnxLogApCrOverrideCntrRowStatus,
tmnxLogApCrOverrideCntrLastChngd,
tmnxLogApCrOverrideCntrICounters,
tmnxLogApCrOverrideCntrECounters
}
STATUS current
DESCRIPTION
"The group of objects supporting custom record counter override
information obsoleted on Nokia SROS series systems in release 21.0."
::= { tmnxLogGroups 65 }
tmnxLogFileNameGroup OBJECT-GROUP
OBJECTS {
tmnxLogFileIdName
}
STATUS current
DESCRIPTION
"The group of additional objects supporting the Log File Id Vs Name
feature on Nokia SROS series systems in release 21."
::= { tmnxLogGroups 66 }
tmnxSnmpTrapDestV22v0Group OBJECT-GROUP
OBJECTS {
tmnxStdDyingGasp
}
STATUS current
DESCRIPTION
"The group of objects added to support SNMP trap destinations in the
Nokia SROS series systems release 22.0."
::= { tmnxLogGroups 67 }
tmnxLogNotifyPrefix OBJECT IDENTIFIER ::= { tmnxSRNotifyPrefix 12 }
tmnxLogNotifications OBJECT IDENTIFIER ::= { tmnxLogNotifyPrefix 0 }
tmnxLogSpaceContention NOTIFICATION-TYPE
OBJECTS {
tmnxLogFileIdRolloverTime,
tmnxLogFileIdRetainTime,
tmnxLogFileIdAdminLocation,
tmnxLogFileIdBackupLoc,
tmnxLogFileIdOperLocation,
tmnxLogFileIdLogId,
tmnxLogFileIdLogType
}
STATUS current
DESCRIPTION
"Generated when space contention occurs on the compact flash where
a log or accounting file creation is being attempted. Space contention
exists if:
Insufficient space is available on the compact flash to create
a file of the same size as the file being rolled over.
The first file of this type is being created and less than
10% of the total compact flash space is available.
A write operation on a log or accounting file is denied due to
lack of space."
::= { tmnxLogNotifications 1 }
tmnxLogAdminLocFailed NOTIFICATION-TYPE
OBJECTS {
tmnxLogFileIdAdminLocation,
tmnxLogFileIdBackupLoc,
tmnxLogFileIdOperLocation,
tmnxLogFileIdLogId,
tmnxLogFileIdLogType
}
STATUS current
DESCRIPTION
"Generated when an attempt to create a log or accounting file at the
location specified by tmnxLogFileIdAdminLocation has failed. Indicates
that the backup location, if specified, will be used."
::= { tmnxLogNotifications 2 }
tmnxLogBackupLocFailed NOTIFICATION-TYPE
OBJECTS {
tmnxLogFileIdAdminLocation,
tmnxLogFileIdBackupLoc,
tmnxLogFileIdOperLocation,
tmnxLogFileIdLogId,
tmnxLogFileIdLogType
}
STATUS current
DESCRIPTION
"Generated when an attempt to create a log or accounting file at the
location specified by tmnxLogFileIdBackupLoc has failed."
::= { tmnxLogNotifications 3 }
tmnxLogFileRollover NOTIFICATION-TYPE
OBJECTS {
tmnxLogFileIdRolloverTime,
tmnxLogFileIdRetainTime,
tmnxLogFileIdAdminLocation,
tmnxLogFileIdBackupLoc,
tmnxLogFileIdOperLocation,
tmnxLogFileIdLogId,
tmnxLogFileIdLogType,
tmnxLogFileIdPathName,
tmnxLogFileIdCreateTime
}
STATUS current
DESCRIPTION
"Generated when an event log or accounting policy file's
rollover time has expired. The file located as indicated
by the value of tmnxLogFileIdOperLocation is closed and a new
file is created as specified by tmnxLogFileIdAdminLocation
and tmnxLogFileIdBackupLoc."
::= { tmnxLogNotifications 4 }
tmnxLogFileDeleted NOTIFICATION-TYPE
OBJECTS {
tmnxLogFileDeletedLogId,
tmnxLogFileDeletedFileId,
tmnxLogFileDeletedLogType,
tmnxLogFileDeletedLocation,
tmnxLogFileDeletedName,
tmnxLogFileDeletedCreateTime
}
STATUS current
DESCRIPTION
"Generated when a closed event log or accounting policy file has been
deleted as part of the space contention cleanup."
::= { tmnxLogNotifications 5 }
tmnxTestEvent NOTIFICATION-TYPE
OBJECTS {
sysDescr,
sysObjectID
}
STATUS current
DESCRIPTION
"The tmnxTestEvent notification is generated when the object
tmnxEventTest is set to a value of 'doAction'. This event can
be used to test that remote log destinations such as syslog and
snmp trap destinations are configured correctly."
::= { tmnxLogNotifications 6 }
tmnxLogTraceError NOTIFICATION-TYPE
OBJECTS {
tmnxLogTraceErrorTitle,
tmnxLogTraceErrorMessage,
tmnxLogTraceErrorSubject
}
STATUS current
DESCRIPTION
"[CAUSE] The tmnxLogTraceError notification is generated when a
critical level trace error has been detected by the software. There
are multiple triggers for such a trace error.
[EFFECT] Effect varies depending on the specific trigger.
[RECOVERY] Contact Nokia Support."
::= { tmnxLogNotifications 7 }
tmnxLogEventThrottled NOTIFICATION-TYPE
OBJECTS {
tmnxLogThrottledEventID,
tmnxLogThrottledEvents
}
STATUS current
DESCRIPTION
"A tmnxLogEventThrottled notification is generated at the end of the
throttling interval when one or more events are dropped because the
throttling limit was reached for that interval."
::= { tmnxLogNotifications 8 }
tmnxSysLogTargetProblem NOTIFICATION-TYPE
OBJECTS {
tmnxSysLogTargetId,
tmnxSysLogTargetProblemDescr
}
STATUS current
DESCRIPTION
"A tmnxSysLogTargetProblem notification is generated when a problem is
encountered when trying to deliver data to the syslog destination
identified by the tmnxSysLogTargetId."
::= { tmnxLogNotifications 9 }
tmnxLogAccountingDataLoss NOTIFICATION-TYPE
OBJECTS {
tmnxLogFileIdRolloverTime,
tmnxLogFileIdRetainTime,
tmnxLogFileIdAdminLocation,
tmnxLogFileIdBackupLoc,
tmnxLogFileIdOperLocation,
tmnxLogFileIdLogId,
tmnxLogNotifyApInterval
}
STATUS current
DESCRIPTION
"A tmnxLogAccountingDataLoss notification is generated
when an accounting file is still being written to
when the next interval ends. The collection of
statistics for the past interval is immediately
stopped and collection is started for the next
interval. There are missing records in the file
for this past interval."
::= { tmnxLogNotifications 10 }
tmnxStdEventsReplayed NOTIFICATION-TYPE
OBJECTS {
tmnxStdDestAddrType,
tmnxStdDestAddr,
tmnxStdReplayStartEvent,
tmnxStdReplayEndEvent,
tmnxStdReplayStart
}
STATUS current
DESCRIPTION
"A tmnxStdEventsReplayed notification is generated when
an SNMP trap target address is added to the RTM (tmnxVRtrID)
following a period when the address had been removed.
The value of tmnxStdReplayStartEvent is the SNMP notification
request ID of the first event that was replayed. The value
of tmnxStdReplayEndEvent is the SNMP notification request ID of the
last missed event that was replayed. The value of
tmnxStdReplayStart is the request ID of the first event for
which there was no route to the trap target address."
::= { tmnxLogNotifications 11 }
tmnxLogEventOverrun NOTIFICATION-TYPE
OBJECTS {
tmnxLogThrottledEventID,
tmnxLogThrottledEvents
}
STATUS current
DESCRIPTION
"[CAUSE] A tmnxLogEventOverrun notification is generated
at the end of the overrun throttling interval when one or more
events of the type specified by tmnxLogThrottledEventID were
dropped because the logger input stream's input queue limit
was exceeded. The overrun throttling interval begins when the
input queue limit is first exceeded and ends when the number of
events in the input queue has dropped below an internal low
watermark. At that point a tmnxLogEventOverrun notification is
generated for each event type that had one or more events dropped
because of the input queue overrun. The number of dropped events
is specified by tmnxLogThrottledEvents.
[EFFECT] Logger events have been dropped and were not sent to any
log destination. tmnxEventDropCount has been incremented for
each event dropped because of input queue overrun.
[RECOVERY] The specific event information of dropped events
cannot be recovered. The frequency of input queue overruns
can be lessened by configuring as few event logs as possible,
especially those going to remote destinations such as file,
syslog and snmp notification logs."
::= { tmnxLogNotifications 12 }
END