RC-MLT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Counter32, Counter64, IpAddress,
TimeTicks
FROM SNMPv2-SMI
DisplayString, TruthValue, RowStatus, MacAddress
FROM SNMPv2-TC
InterfaceIndex, InterfaceIndexOrZero
FROM IF-MIB
rcMlt, rcStat, rcLinkFlapDetect, rcL2Redundancy,
PortSet, IdList, EnableValue
FROM RAPID-CITY;
rcMltMib MODULE-IDENTITY
LAST-UPDATED "200512060000Z"
ORGANIZATION "Bay Networks, Rapid-City Group"
CONTACT-INFO "Yu-Ten Lee
Postal: Nortel Networks
4655 Great America Parkway
Santa Clara, CA 95052-8185
Tel: 408-495-2560
Fax: 408-495-6680
E-mail: ylee@nortelnetworks.com"
DESCRIPTION "Enterprise MIB for the Accelar product family."
REVISION "200512060000Z" -- 06 Dec 2005
DESCRIPTION "Version 13: Changed range of rcMltSmltId to 0..256."
REVISION "200509010000Z" -- 01 Sep 2005
DESCRIPTION "Version 12: Changed rcMltEnable from read-only to read-create.
Changed all read-write objects in rcMltTable
to read-create."
REVISION "200508100000Z" -- 10 Aug 2005
DESCRIPTION "Version 11: Increased to rcMltId & rcMltSmltId from 32 to 256"
REVISION "200507110000Z" -- 11 July 2005
DESCRIPTION "Version 10: Added enumerations to rcMltDistributionAlgorithm."
REVISION "200505270000Z" -- 05 Apr 2005
DESCRIPTION "Version 9: Fixed range of rcMltVlanIds, allow rcMltIfIndex to be 0."
REVISION "200502020000Z" -- 02 Feb 2005
DESCRIPTION "Version 8: Changed the SYNTAX for rcStatMltIfUtilIfHCInUtil &
rcStatMltIfUtilIfHCOutUtil to Gauge32"
REVISION "200501040000Z" -- 04 Jan 2005
DESCRIPTION "Version 7: Made Index rcStatMltIfUtilMltId as not-accessible"
REVISION "200412210000Z" -- 21 Dec 2004
DESCRIPTION "Version 6: Added rcStatMltIfUtilTable"
REVISION "200409300000Z" -- 30 Sept 2004
DESCRIPTION "Version 5: Import MacAddress type"
REVISION "200409230000Z" -- 23 Sept 2004
DESCRIPTION "Version 4: Added rcMltVlacpTable"
REVISION "200407130000Z" -- 13 July 2004
DESCRIPTION "Version 3: Added rcMltVlacpTable"
::= { rcMlt 0 }
-- rcStatMlt Group
rcStatMlt OBJECT IDENTIFIER ::= { rcStat 6 }
rcStatMltIfExtnTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcStatMltIfExtnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table used to store Mlt interface
statistics."
::= { rcStatMlt 1 }
rcStatMltIfExtnEntry OBJECT-TYPE
SYNTAX RcStatMltIfExtnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Mlt interface statistics"
INDEX { rcStatMltIfExtnMltId }
::= { rcStatMltIfExtnTable 1 }
RcStatMltIfExtnEntry ::= SEQUENCE {
rcStatMltIfExtnMltId INTEGER,
rcStatMltIfExtnIfInMulticastPkts Counter32,
rcStatMltIfExtnIfInBroadcastPkts Counter32,
rcStatMltIfExtnIfOutMulticastPkts Counter32,
rcStatMltIfExtnIfOutBroadcastPkts Counter32,
rcStatMltIfExtnIfHCInOctets Counter64,
rcStatMltIfExtnIfHCInUcastPkts Counter64,
rcStatMltIfExtnIfHCInMulticastPkt Counter64,
rcStatMltIfExtnIfHCInBroadcastPkt Counter64,
rcStatMltIfExtnIfHCOutOctets Counter64,
rcStatMltIfExtnIfHCOutUcastPkts Counter64,
rcStatMltIfExtnIfHCOutMulticast Counter64,
rcStatMltIfExtnIfHCOutBroadcast Counter64
}
rcStatMltIfExtnMltId OBJECT-TYPE
SYNTAX INTEGER (1..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Mlt Id"
::= { rcStatMltIfExtnEntry 1 }
rcStatMltIfExtnIfInMulticastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "multi-pkts to upper"
::= { rcStatMltIfExtnEntry 2 }
rcStatMltIfExtnIfInBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "broad-pkts to upper"
::= { rcStatMltIfExtnEntry 3 }
rcStatMltIfExtnIfOutMulticastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "multi-pkts from upper"
::= { rcStatMltIfExtnEntry 4 }
rcStatMltIfExtnIfOutBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "broad-pkts from upper"
::= { rcStatMltIfExtnEntry 5 }
rcStatMltIfExtnIfHCInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of octets received
on the MLT interface, including framing
characters."
::= { rcStatMltIfExtnEntry 6 }
rcStatMltIfExtnIfHCInUcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of packets delivered by this
MLT to a higher MLT that were not addressed
to a nulticast or broadcase address at this
sublayer."
::= { rcStatMltIfExtnEntry 7 }
rcStatMltIfExtnIfHCInMulticastPkt OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of packets delivered to this MLT that
were addressed to a nulticast address at this
sublayer. For a MAC layer protocol, this number
includes both Group and Functional addresses."
::= { rcStatMltIfExtnEntry 8 }
rcStatMltIfExtnIfHCInBroadcastPkt OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of packets delivered to this MLT that
were addressed to a broadcast address at this
sublayer."
::= { rcStatMltIfExtnEntry 9 }
rcStatMltIfExtnIfHCOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of octets transmitted
out of the MLT interface, including
framing characters."
::= { rcStatMltIfExtnEntry 10 }
rcStatMltIfExtnIfHCOutUcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of packets that hight-level protocols
requested be transmitted that were not addressed
to a multicast address at this MLT. This total
number includes those packets discarded or unsent."
::= { rcStatMltIfExtnEntry 11 }
rcStatMltIfExtnIfHCOutMulticast OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of packets that hight-level
protocols requested be transmitted, and that
were addressed to a multicast address at this
MLT, including those that were discarded or
not sent. For a MAC layer protocol, this
number includes both Group and Functional
addresses."
::= { rcStatMltIfExtnEntry 12 }
rcStatMltIfExtnIfHCOutBroadcast OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of packets that hight-level
protocols requested be transmitted, and that
were addressed to a broadcase address at this
MLT, including those that were discarded or
not sent."
::= { rcStatMltIfExtnEntry 13 }
-- Mlt Ether table
rcStatMltEtherTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcStatMltEtherEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table used to store Mlt Ethernet
statistics."
::= { rcStatMlt 2 }
rcStatMltEtherEntry OBJECT-TYPE
SYNTAX RcStatMltEtherEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Mlt enternet statistics"
INDEX { rcStatMltEtherMltId }
::= { rcStatMltEtherTable 1 }
RcStatMltEtherEntry ::= SEQUENCE {
rcStatMltEtherMltId INTEGER,
rcStatMltEtherAlignmentErrors Counter32,
rcStatMltEtherFCSErrors Counter32,
rcStatMltEtherSingleCollFrames Counter32,
rcStatMltEtherMultipleCollFrames Counter32,
rcStatMltEtherSQETestError Counter32,
rcStatMltEtherDeferredTransmiss Counter32,
rcStatMltEtherLateCollisions Counter32,
rcStatMltEtherExcessiveCollis Counter32,
rcStatMltEtherIMacTransmitError Counter32,
rcStatMltEtherCarrierSenseError Counter32,
rcStatMltEtherFrameTooLong Counter32,
rcStatMltEtherIMacReceiveError Counter32
}
rcStatMltEtherMltId OBJECT-TYPE
SYNTAX INTEGER (1..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value that uniquely identifies the Multi-Link
Trunk associated with this entry."
::= { rcStatMltEtherEntry 1 }
rcStatMltEtherAlignmentErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames received on a particular MLT
that are not an integral number of octets in
length and do not pass the FCS check. The count
represented by an instance of this object is
incremented when the alignmentError status is
returned by the MAC service to the LLC (or other
MAC user). Received frames for which multiple
error conditions occur are, according to the
conventions of IEEE 802.3 Layer Management,
counted exclusively according to the error status
presented to the LLC."
::= { rcStatMltEtherEntry 2 }
rcStatMltEtherFCSErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames received on an MLT that are an
integral number of octets in length but do not pass
the FCS check. The count represented by an instance
of this object is incremented when the frameCheckError
status is returned by the MAC service to the LLC
(or other MAC user). Received frames for which
multiple error conditions occur are, according to
the conventions of IEEE 802.3 Layer Management,
counted exclusively according to the error status
presented to the LLC."
::= { rcStatMltEtherEntry 3 }
rcStatMltEtherSingleCollFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of successfully transmitted frames on
a particular MLT for which transmission is
inhibited by exactly one collision. A frame
that is counted by an instance of this objects
is also counted by the corresponding instance
of either the ifOutUcastPkts, ifOutMulticastPkts,
or ifOutBroadcastPkts, and it not counted by the
corresponding instance of the MultipleCollisionFrames
object."
::= { rcStatMltEtherEntry 4 }
rcStatMltEtherMultipleCollFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of successfully transmitted frames on
a particular MLT for which transmission is
inhibited by more than one collision. A frame
that is counted by an instance of this object
is also counted by the corresponding instance
of either the ifOutUcastPkts, ifOutMulticastPkts,
or ifOutBroadcastPkts, and is not counted by the
corresponding instance of the SingleCollisionFrames
objects."
::= { rcStatMltEtherEntry 5 }
rcStatMltEtherSQETestError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of times that the SQE TEST ERROR message
is generated by the PLS sublayer for a particular
MLT. SQE stands for Signal Quality Error."
::= { rcStatMltEtherEntry 6 }
rcStatMltEtherDeferredTransmiss OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames for which the first transmission
attempt on a particular MLT is delayed because the
medium is busy. The count represented by an
instance of this object does not include frames
involved in collisions."
::= { rcStatMltEtherEntry 7 }
rcStatMltEtherLateCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of times that a collision is detected
on a particular MLT later than 512 bit-times
(64 octets) into the transmission of a packet.
Five hundred and twelve bit-times corresponds to
51.2 microseconds on a 10 mb/s system. A (late)
collision included in a count represented by an
instance of this object is also considered as a
(generic) collision for purposes of other
collision-related statistics."
::= { rcStatMltEtherEntry 8 }
rcStatMltEtherExcessiveCollis OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames for which transmission on a
particular MLT fails due to excessive collisions."
::= { rcStatMltEtherEntry 9 }
rcStatMltEtherIMacTransmitError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames for which transmission on a
particular MLT fails due to an internal MAC
sublayer transmit error. A frame is only counted
by an instance of this object if it is not counted
by the corresponding instance of either the
LateCollisions object, the ExcessiveCollisions
object, or the CarrierSenseError object."
::= { rcStatMltEtherEntry 10 }
rcStatMltEtherCarrierSenseError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of times that the carrier sense
condition was lost or never asserted when
attempting to transmit a frame on a particular
MLT. The count represented by an instance of
this object is incremented at most once per
transmission attempt, even if the carrier
sense condition fluctuates during a
transmission attempt."
::= { rcStatMltEtherEntry 11 }
rcStatMltEtherFrameTooLong OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames received on a particular MLT
that exceed the maximum permitted size (1518
octets). The count represented by an instance
os this object is incremented when the frame
TooLong status is returned by the MAC service
to the LLC (or other MAC user). Received frames
for which multiple error conditions occur are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC."
::= { rcStatMltEtherEntry 12 }
rcStatMltEtherIMacReceiveError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames for which reception on a
particular MLT fails due to an internal MAC
sublayer receive error. A frame is only
counted by an instance of this object if it
is not counted by the corresponding instance
of either the FrameTooLongs object, the
AlignmentErrors object, of the FCSErrors
objects.
The precise meaning of the count represented
by an instance of this object is implementation
specific. In particular, an instance of this
object may represent a count of receive errors
on a particular interface that are not otherwise
counted."
::= { rcStatMltEtherEntry 13 }
-- Mlt Ip table
rcStatMltIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcStatMltIpEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "A table used to store Mlt Ip statistics."
::= { rcStatMlt 3 }
rcStatMltIpEntry OBJECT-TYPE
SYNTAX RcStatMltIpEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "Mlt enternet statistics"
INDEX { rcStatMltIpMltId }
::= { rcStatMltIpTable 1 }
RcStatMltIpEntry ::= SEQUENCE {
rcStatMltIpMltId INTEGER,
rcStatMltIpInReceives Counter32,
rcStatMltIpInHdrErrors Counter32,
rcStatMltIpInAddrErrors Counter32,
rcStatMltIpForwDatagrams Counter32,
rcStatMltIpInUnknownProtos Counter32,
rcStatMltIpInDiscards Counter32,
rcStatMltIpInDelivers Counter32,
rcStatMltIpOutRequest Counter32,
rcStatMltIpOutDiscards Counter32,
rcStatMltIpOutNoRoutes Counter32,
rcStatMltIpReasmReqds Counter32,
rcStatMltIpReasmOKs Counter32,
rcStatMltIpReasmFails Counter32,
rcStatMltIpFragOKs Counter32,
rcStatMltIpFragFails Counter32,
rcStatMltIpFragCreates Counter32,
rcStatMltIpRoutingDiscards Counter32
}
rcStatMltIpMltId OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Mlt Id"
::= { rcStatMltIpEntry 1 }
rcStatMltIpInReceives OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "all incoming packets"
::= { rcStatMltIpEntry 2 }
rcStatMltIpInHdrErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "hdr errors detected"
::= { rcStatMltIpEntry 3 }
rcStatMltIpInAddrErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "bad dest. ip addr"
::= { rcStatMltIpEntry 4 }
rcStatMltIpForwDatagrams OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "packets forwarded"
::= { rcStatMltIpEntry 5 }
rcStatMltIpInUnknownProtos OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "unsupported protocol"
::= { rcStatMltIpEntry 6 }
rcStatMltIpInDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "good, but no buffer"
::= { rcStatMltIpEntry 7 }
rcStatMltIpInDelivers OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "pkts delivered to upper"
::= { rcStatMltIpEntry 8 }
rcStatMltIpOutRequest OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "pkts received from upper"
::= { rcStatMltIpEntry 9 }
rcStatMltIpOutDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "good, but no buffer"
::= { rcStatMltIpEntry 10 }
rcStatMltIpOutNoRoutes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "no route to destination"
::= { rcStatMltIpEntry 11 }
rcStatMltIpReasmReqds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "fragments to reassem"
::= { rcStatMltIpEntry 12 }
rcStatMltIpReasmOKs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "reassembled successfully"
::= { rcStatMltIpEntry 13 }
rcStatMltIpReasmFails OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "reassembly failures"
::= { rcStatMltIpEntry 14 }
rcStatMltIpFragOKs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "fragment successfully"
::= { rcStatMltIpEntry 15 }
rcStatMltIpFragFails OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "fragment failure"
::= { rcStatMltIpEntry 16 }
rcStatMltIpFragCreates OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "pkts due to fragmenting"
::= { rcStatMltIpEntry 17 }
rcStatMltIpRoutingDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Route entries removed"
::= { rcStatMltIpEntry 18 }
-- SMLT IST
rcStatSmltIstDownCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts how the session between the
two peering switches has done down since last boot."
::= { rcStatMlt 4 }
rcStatSmltHelloTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx hello msg."
::= { rcStatMlt 5 }
rcStatSmltHelloRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx hello msg."
::= { rcStatMlt 6 }
rcStatSmltLearnMacAddrTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx learn Mac Address msg."
::= { rcStatMlt 7 }
rcStatSmltLearnMacAddrRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx learn Mac Address msg."
::= { rcStatMlt 8 }
rcStatSmltMacAddrAgeOutTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx Mac Address Aging Out msg."
::= { rcStatMlt 9 }
rcStatSmltMacAddrAgeOutRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx Mac Address Aging Out msg."
::= { rcStatMlt 10 }
rcStatSmltMacAddrAgeExpTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx Mac Address age expired msg."
::= { rcStatMlt 11 }
rcStatSmltMacAddrAgeExpRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx Mac Address age expired msg."
::= { rcStatMlt 12 }
rcStatSmltStgInfoTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx Stg information msg."
::= { rcStatMlt 13 }
rcStatSmltStgInfoRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx Stg information msg."
::= { rcStatMlt 14 }
rcStatSmltDelMacAddrTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx deleted MAC address msg."
::= { rcStatMlt 15 }
rcStatSmltDelMacAddrRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx deleted MAC address msg."
::= { rcStatMlt 16 }
rcStatSmltSmltDownTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx Smlt Down msg."
::= { rcStatMlt 17 }
rcStatSmltSmltDownRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx Smlt Down msg."
::= { rcStatMlt 18 }
rcStatSmltSmltUpTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx Smlt Up msg."
::= { rcStatMlt 19 }
rcStatSmltSmltUpRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx Smlt Up msg."
::= { rcStatMlt 20 }
rcStatSmltSendMacTblTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx Send Mac Table msg."
::= { rcStatMlt 21 }
rcStatSmltSendMacTblRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx Send Mac Table msg."
::= { rcStatMlt 22 }
rcStatSmltIgmpTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx Igmp msg."
::= { rcStatMlt 23 }
rcStatSmltIgmpRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx Igmp msg."
::= { rcStatMlt 24 }
rcStatSmltPortDownTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx port down msg."
::= { rcStatMlt 25 }
rcStatSmltPortDownRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx port down msg."
::= { rcStatMlt 26 }
rcStatSmltReqMacTblTxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the tx request Mac table msg."
::= { rcStatMlt 27 }
rcStatSmltReqMacTblRxMsgCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx request Mac table msg."
::= { rcStatMlt 28 }
rcStatSmltRxUnknownMsgTypeCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Counters that counts the rx unknown msg type."
::= { rcStatMlt 29 }
rcStatMltIfUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcStatMltIfUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table used to store Mlt interface utilization."
::= { rcStatMlt 30 }
rcStatMltIfUtilEntry OBJECT-TYPE
SYNTAX RcStatMltIfUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Mlt interface utilization"
INDEX { rcStatMltIfUtilMltId }
::= { rcStatMltIfUtilTable 1 }
RcStatMltIfUtilEntry ::= SEQUENCE {
rcStatMltIfUtilMltId INTEGER,
rcStatMltIfUtilIfHCInOctets Counter64,
rcStatMltIfUtilIfHCInUtil Gauge32,
rcStatMltIfUtilIfHCOutOctets Counter64,
rcStatMltIfUtilIfHCOutUtil Gauge32
}
rcStatMltIfUtilMltId OBJECT-TYPE
SYNTAX INTEGER (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "To assign an Id within the range specified to the
Mlt created "
::= { rcStatMltIfUtilEntry 1 }
rcStatMltIfUtilIfHCInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of octets received
on the MLT interface, including framing characters."
::= { rcStatMltIfUtilEntry 2 }
rcStatMltIfUtilIfHCInUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The best estimate of the mean physical layer network
utilization on this interface during this interval,
in percent."
::= { rcStatMltIfUtilEntry 3}
rcStatMltIfUtilIfHCOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of octets transmitted out of the
MLT interface, including framing characters."
::= { rcStatMltIfUtilEntry 4 }
rcStatMltIfUtilIfHCOutUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The best estimate of the mean physical layer network
utilization on this interface during this interval,
in percent."
::= { rcStatMltIfUtilEntry 5 }
-- Multi-Link Trunking Table
rcMltNumMlts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of MLTs currently defined in the switch."
::= { rcMlt 1 }
rcMltPotentialMembers OBJECT-TYPE
SYNTAX PortSet
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The set of ports that are not members of any MLT."
::= { rcMlt 2 }
rcMltIstSessionEnable OBJECT-TYPE
SYNTAX EnableValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable/disable mlt functionality."
::= { rcMlt 3 }
rcMltIstSessionStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to enable/disable mlt functionality."
::= { rcMlt 4 }
rcMltIstPeerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IST mlt Peer Ip address."
::= { rcMlt 5 }
rcMltIstVlanId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IST mlt Vlan Id."
::= { rcMlt 6 }
rcMltTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcMltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of Multi-Link Trunk entries. The number of
entries is given by rcMltNumMlts."
::= { rcMlt 10 }
rcMltEntry OBJECT-TYPE
SYNTAX RcMltEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing configuration information for a
particular Multi-Link Trunk."
INDEX { rcMltId }
::= { rcMltTable 1 }
RcMltEntry ::= SEQUENCE {
rcMltId INTEGER,
rcMltName DisplayString,
rcMltPortMembers PortSet,
rcMltPortType INTEGER,
rcMltNumVlanIds Integer32,
rcMltVlanIds IdList,
rcMltRowStatus RowStatus,
rcMltEnable TruthValue,
rcMltLoadBalance TruthValue,
rcMltDistributionAlgorithm INTEGER,
rcMltIfIndex InterfaceIndexOrZero,
rcMltMltType INTEGER,
rcMltSmltId INTEGER,
rcMltRunningType INTEGER,
rcMltSvlanPortType INTEGER,
rcMltMulticastDistribution EnableValue,
rcMltLacp10gBackup EnableValue,
rcMltAggregatable EnableValue,
rcMltClearLinkAggregate INTEGER,
rcMltNtStgEnable TruthValue,
rcMltDesignatedPort InterfaceIndex,
rcMltAggOperState EnableValue,
rcMltAggTimeOfLastOperChange TimeTicks,
rcMltVplsMgmtVlan EnableValue
}
rcMltId OBJECT-TYPE
SYNTAX INTEGER (1..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value that uniquely identifies the Multi-Link
Trunk associated with this entry."
::= { rcMltEntry 1 }
rcMltName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An administratively-assigned name for this MLT."
::= { rcMltEntry 2 }
rcMltPortMembers OBJECT-TYPE
SYNTAX PortSet
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The set of ports that are members of this MLT."
::= { rcMltEntry 3 }
rcMltPortType OBJECT-TYPE
SYNTAX INTEGER {
access(1), -- access port type
trunk(2) -- trunk port type
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of MLT port: access(1) or trunk(2)."
DEFVAL { access }
::= { rcMltEntry 4 }
rcMltNumVlanIds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of VLAN IDs that
are stored in the rcMltVlanIds variable."
::= { rcMltEntry 5 }
rcMltVlanIds OBJECT-TYPE
SYNTAX IdList (SIZE (0..8192))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "An array used to identify which VLANs this MLT
is associated with. Each VLAN ID is stored as a
two octet value. The first octet in the pair holds
bits 15-8 of the VLAN ID, while the second octet
holds bits 7-0 of the VLAN ID."
::= { rcMltEntry 6 }
rcMltRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to create/delete entries in the rcMltTable."
::= { rcMltEntry 7 }
rcMltEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Enable the entry."
DEFVAL { true }
::= { rcMltEntry 8 }
rcMltLoadBalance OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Perform load balance?"
DEFVAL { false }
::= { rcMltEntry 9 }
rcMltDistributionAlgorithm OBJECT-TYPE
SYNTAX INTEGER {
none(1),
basic(2),
advanced(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The load balancing algorithm."
DEFVAL { none }
::= { rcMltEntry 10 }
rcMltIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the 'logical' ifIndex assigned to
this MLT."
::= { rcMltEntry 11 }
rcMltMltType OBJECT-TYPE
SYNTAX INTEGER {
normalMLT(1),
istMLT(2),
splitMLT(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "MLT type."
::= { rcMltEntry 12 }
rcMltSmltId OBJECT-TYPE
SYNTAX INTEGER (0..256)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Split MLT id."
::= { rcMltEntry 13 }
rcMltRunningType OBJECT-TYPE
SYNTAX INTEGER {
normalMLT(1),
istMLT(2),
splitMLT(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Split MLT running type."
::= { rcMltEntry 14 }
rcMltSvlanPortType OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
uni(2),
nni(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Set MLT port type."
DEFVAL { normal }
::= { rcMltEntry 15 }
rcMltMulticastDistribution OBJECT-TYPE
SYNTAX EnableValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Enable/Disable multicast distribution per mlt."
DEFVAL { disable }
::= { rcMltEntry 16 }
rcMltLacp10gBackup OBJECT-TYPE
SYNTAX EnableValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Enable/Disable 10G Mlt reliance backup mode."
DEFVAL { disable }
::= { rcMltEntry 17 }
rcMltAggregatable OBJECT-TYPE
SYNTAX EnableValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Enable/Disable link aggregation on a MLT."
DEFVAL { disable }
::= { rcMltEntry 18 }
rcMltClearLinkAggregate OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
none(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "clear link aggregate, equivalent to disable and
re-enable aggregatable on the MLT."
::= { rcMltEntry 19 }
rcMltNtStgEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicates whether this MLT is operating in
Nortel Mode or in Cisco Mode.
true = Nortel Mode
false = Cisco Mode."
DEFVAL { true }
::= { rcMltEntry 20 }
rcMltDesignatedPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the Designated port for the MLT."
::= { rcMltEntry 21 }
rcMltAggOperState OBJECT-TYPE
SYNTAX EnableValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Link aggregation state on a MLT."
::= { rcMltEntry 22 }
rcMltAggTimeOfLastOperChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time value since the interface entered its
current operational state."
::= { rcMltEntry 23 }
rcMltVplsMgmtVlan OBJECT-TYPE
SYNTAX EnableValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Management Vlan is configured on this mlt"
DEFVAL { disable }
::= { rcMltEntry 24 }
rcMltMcastDistribution OBJECT IDENTIFIER ::= { rcMlt 11 }
rcMltMcastDistributionEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable/disable this feature to
distribute multicast traffic on MLT ports. All
the cards in the system must be E-Tickets.
Cannot perform distribution in a mixed mode."
::= { rcMltMcastDistribution 1 }
rcMltMcastDistributionGrpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Group Mask. Create a MLT abstraction layer to
distribute traffic basd on (source, group) information
of the multicast packet. The algorithm to pick
the actual port nedds to generate a fairly random
number for different combinations but a lways generate
the same number for a given (source, group) pair. By
default, the number of active ports of the MLT is used
to MOD the pseudo-random number generated by the XOR
of each byte of the masked group address with the
masked source address."
::= { rcMltMcastDistribution 2 }
rcMltMcastDistributionSrcMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Source Mask."
::= { rcMltMcastDistribution 3 }
rcMltMcastDistributionRedistributionEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable redistribution."
::= { rcMltMcastDistribution 4 }
-- Single Link Trunk Port Table
rcSltPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSltPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { rcMlt 12 }
rcSltPortEntry OBJECT-TYPE
SYNTAX RcSltPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing configuration information for a
particular Multi-Link Trunk."
INDEX { rcSltPortIfIndex }
::= { rcSltPortTable 1 }
RcSltPortEntry ::= SEQUENCE {
rcSltPortIfIndex InterfaceIndex,
rcSltPortSmltId INTEGER,
rcSltPortOperType INTEGER,
rcSltPortRowStatus RowStatus
}
rcSltPortIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An interface for this SLT."
::= { rcSltPortEntry 1 }
rcSltPortSmltId OBJECT-TYPE
SYNTAX INTEGER (1..512)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A uniquely identifies the Single-Link
Trunk associated with this entry."
::= { rcSltPortEntry 2 }
rcSltPortOperType OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
smlt(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current operate type of the port normal
or smlt."
::= { rcSltPortEntry 3 }
rcSltPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to create/delete entries of the Table."
::= { rcSltPortEntry 4 }
-- rcMltVlacpTable
rcMltVlacpTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcMltVlacpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Mlt Virtual LACP table"
::= { rcMlt 13 }
rcMltVlacpEntry OBJECT-TYPE
SYNTAX RcMltVlacpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing info. for a particular port"
INDEX { rcMltId }
::= { rcMltVlacpTable 1 }
RcMltVlacpEntry ::= SEQUENCE {
rcMltVlacpAdminEnable TruthValue,
rcMltVlacpFastPeriodicTimer Integer32,
rcMltVlacpTimeoutScale Integer32,
rcMltVlacpEtherMacAddress MacAddress,
rcMltVlacpDualHomingEnable TruthValue
}
rcMltVlacpAdminEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Administratively enable/disable Virtual LACP on a MLT"
DEFVAL { false }
::= { rcMltVlacpEntry 1 }
rcMltVlacpFastPeriodicTimer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The number of miliseconds between periodic transmissions
using Short Timeouts"
DEFVAL { 250 }
::= { rcMltVlacpEntry 2 }
rcMltVlacpTimeoutScale OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Scalar value used to calculate timeout time from
periodic time. Timeout = PeriodicTime * TimeoutScale"
DEFVAL { 3 }
::= { rcMltVlacpEntry 3 }
rcMltVlacpEtherMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Multicast Mac Address exclusively used for VLACPDU's"
::= { rcMltVlacpEntry 4 }
rcMltVlacpDualHomingEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/Disable Dual homing on Virtual LACP on a MLT"
DEFVAL { false }
::= { rcMltVlacpEntry 5 }
-- Link Flap Detect Group
rcLinkFlapDetectAutoPortDownEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable/disable the Link Flap Detect
feature. When enabled this feature will monitor
the number of times a port goes down during a
certain interval. If the number exceeds a given
bound the port will be forced out-of-service."
::= { rcLinkFlapDetect 1 }
rcLinkFlapDetectSendTrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to configure whether a trap should be
sent if the port is forced out-of-service."
::= { rcLinkFlapDetect 2 }
rcLinkFlapDetectFrequency OBJECT-TYPE
SYNTAX INTEGER (1..9999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to configure the number of times the port
can go down."
::= { rcLinkFlapDetect 3 }
rcLinkFlapDetectInterval OBJECT-TYPE
SYNTAX INTEGER (2..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to configure the interval (in minutes)."
::= { rcLinkFlapDetect 4 }
-- rcL2Redundancy Group
rcL2RedundancyHaCpuState OBJECT-TYPE
SYNTAX INTEGER
{
initialization(0),
oneWayActive(1),
twoWayActive(2),
synchronized(3),
remoteIncompatible(4),
error(5),
disabled(6),
peerNotConnected(7),
peerConnected(8),
lostPeerConnection(9),
notSynchronized(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicate the Ha-CPU state.
initialization - indicate the CPU is in this state.
oneWayActive - Modules that need to be
synchronized have registered with the framework (either
locally or a message was received from remote CPU (1).
twoWayActive - Modules that need to be synchronized have
registered with the framework (either locally or a message
was received from remote CPU (2).
synchronized - Table based synchroniztion was completed
on the current CPU (3).
remoteIncompatible - CPUs framework version is incompatible
with the remote CPU (4).
error - If an invalid event is generated in a given state the
CPU enters Error state (5).
disabled - High Availability is not enabled (6).
peerNotConnected - no peer connection is established (7).
peerConnected - peer connection is established (8).
lostPeerConnection - lost connection to peer/Standby CPU (9).
notSynchronized - Table Sync is not complete (10)."
::= { rcL2Redundancy 1 }
rcL2RedundancyHaEvent OBJECT-TYPE
SYNTAX INTEGER
{
restart(0),
systemRegistrationDone(1),
tableSynchronizationDone(2),
versionIncompatible(3),
noEvent(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicate the Ha event status.
restart (0) - Causes the state machine to restart
systemRegistrationDone (1)- Causes the CPU to transfer to
One Way or Two Way Active state. Locally or message received
from remote CPU.
tableSynchronizationDone (2) - Causes the CPU to
transfer to Synchronized state.
versionIncompatible (3) - Causes the CPU to go to Remote
Incompatible state
noEvent (4) - Means no event has occured uptill now. "
::= { rcL2Redundancy 2 }
rcL2RedundancyEnable OBJECT-TYPE
SYNTAX EnableValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicate the feature enable/disable."
::= { rcL2Redundancy 3 }
rcL2RedundancyStandbyCpu OBJECT-TYPE
SYNTAX INTEGER {
hotStandbyCPU(1),
warmStandbyCPU(2),
standbyCPUNotPresent(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicate if the L2 Redundancy is enabled on the standby CPU."
::= { rcL2Redundancy 4 }
END