mibs/MIBS/nti/ENVIROMUXMICRO-MIB

556 lines
17 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
ENVIROMUXMICRO-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
enterprises,
Integer32 FROM SNMPv2-SMI
DisplayString FROM SNMPv2-TC;
enviromuxMicro MODULE-IDENTITY
LAST-UPDATED "202103071400Z"
ORGANIZATION "Network Technologies Inc."
CONTACT-INFO
"Network Technologies Inc.
Postal: 1275 Danner Dr,
Aurora, OH 442022
US
Tel: 330-562-7070
Fax: 330-562-1999
WEB: www.networktechinc.com"
DESCRIPTION
"E-MICRO MIB file."
REVISION "202103071400Z"
DESCRIPTION "Rev. 1.04 - Added hostSystem variables"
REVISION "201509271400Z"
DESCRIPTION "Rev. 1.03 - Added Smart Alerts OID's"
REVISION "201502231400Z"
DESCRIPTION "Rev. 1.02 - Added traps OID's"
REVISION "201411251400Z"
DESCRIPTION "Rev. 1.01 - Corrected missing elements"
REVISION "201411141400Z"
DESCRIPTION "Rev. 1.00 - Initial version"
::= { hardware 12 }
-- the root of the subtree for Network Technologies Inc
nti OBJECT IDENTIFIER ::= { enterprises 3699 }
-- subtree for products
products OBJECT IDENTIFIER ::= { nti 1 }
hardware OBJECT IDENTIFIER ::= { products 1 }
software OBJECT IDENTIFIER ::= { products 2 }
otherProduct OBJECT IDENTIFIER ::= { hardware 200 }
-- e-micro subtree
masterUnit OBJECT IDENTIFIER ::= { enviromuxMicro 1 }
intSensors OBJECT IDENTIFIER ::= { masterUnit 1 }
extSensors OBJECT IDENTIFIER ::= { masterUnit 2 }
digInputs OBJECT IDENTIFIER ::= { masterUnit 3 }
ipDevices OBJECT IDENTIFIER ::= { masterUnit 4 }
eAlerts OBJECT IDENTIFIER ::= { masterUnit 5 }
smAlerts OBJECT IDENTIFIER ::= { masterUnit 6 }
hostSystem OBJECT IDENTIFIER ::= { masterUnit 100 }
enviromuxMicroTraps OBJECT IDENTIFIER ::= { enviromuxMicro 100 }
-- integrated sensors description
intSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of internal Sensors entries"
::= { intSensors 1 }
intSensorEntry OBJECT-TYPE
SYNTAX IntSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An internal sensor entry"
INDEX { intSensorIndex }
::= { intSensorTable 1 }
IntSensorEntry ::=
SEQUENCE {
intSensorIndex
Integer32,
intSensorType
INTEGER,
intSensorDescription
DisplayString,
intSensorValue
INTEGER,
intSensorUnit
Integer32
}
intSensorIndex OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The index of the integrated sensor entry 1..3"
::= { intSensorEntry 1 }
intSensorType OBJECT-TYPE
SYNTAX INTEGER { undefined(0), temperature(1), humidity(2), dewPoint(24) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sensor Type"
::= { intSensorEntry 2 }
intSensorDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sensor Description"
::= { intSensorEntry 3 }
intSensorValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the integrated sensor reading. For temperature, voltage, current or low voltage, it is presented in tenths of degrees/volts"
::= { intSensorEntry 4 }
intSensorUnit OBJECT-TYPE
SYNTAX Integer32 (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The measuremnet unit for this sensor in numeric format. It is important only for temperature"
::= { intSensorEntry 5 }
-- external sensors description
extSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExtSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of external Sensors entries"
::= { extSensors 1 }
extSensorEntry OBJECT-TYPE
SYNTAX ExtSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An external sensor entry"
INDEX { extSensorIndex }
::= { extSensorTable 1 }
ExtSensorEntry ::=
SEQUENCE {
extSensorIndex
Integer32,
extSensorType
INTEGER,
extSensorDescription
DisplayString,
extSensorValue
INTEGER,
extSensorUnit
Integer32
}
extSensorIndex OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The index of the external sensor entry 1..6"
::= { extSensorEntry 1 }
extSensorType OBJECT-TYPE
SYNTAX INTEGER { undefined(0), temperature(1), humidity(2), dewPoint(24) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sensor Type"
::= { extSensorEntry 2 }
extSensorDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sensor Description"
::= { extSensorEntry 3 }
extSensorValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the external sensor reading. For temperature, voltage, current or low voltage, it is presented in tenths of degrees/volts"
::= { extSensorEntry 4 }
extSensorUnit OBJECT-TYPE
SYNTAX Integer32 (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The measuremnet unit for this sensor in numeric format. It is important only for temperature"
::= { extSensorEntry 5 }
-- digital inputs description
digInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF DigInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of digital input entries"
::= { digInputs 1 }
digInputEntry OBJECT-TYPE
SYNTAX DigInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A digital input entry"
INDEX { digInputIndex }
::= { digInputTable 1 }
DigInputEntry ::=
SEQUENCE {
digInputIndex
Integer32,
digInputDescription
DisplayString,
digInputValue
INTEGER
}
digInputIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The index of the digital input entry 1..2"
::= { digInputEntry 1 }
digInputDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sensor Description"
::= { digInputEntry 2 }
digInputValue OBJECT-TYPE
SYNTAX INTEGER { closed(0), open(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the digital reading"
::= { digInputEntry 3 }
-- ip devices description
ipDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of digital input entries"
::= { ipDevices 1 }
ipDeviceEntry OBJECT-TYPE
SYNTAX IpDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A digital input entry"
INDEX { ipDeviceIndex }
::= { ipDeviceTable 1 }
IpDeviceEntry ::=
SEQUENCE {
ipDeviceIndex
Integer32,
ipDeviceDescription
DisplayString,
ipDeviceValue
INTEGER
}
ipDeviceIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The index of the ip device entry 1..4"
::= { ipDeviceEntry 1 }
ipDeviceDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Sensor Description"
::= { ipDeviceEntry 2 }
ipDeviceValue OBJECT-TYPE
SYNTAX INTEGER { notResponding(0), responding(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The result of the ip device ping test"
::= { ipDeviceEntry 3 }
-- alerts description
alertTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of alert entries"
::= { eAlerts 1 }
alertEntry OBJECT-TYPE
SYNTAX AlertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An alert entry"
INDEX { alertIndex }
::= { alertTable 1 }
AlertEntry ::=
SEQUENCE {
alertIndex
Integer32,
alertEnabled
Integer32,
alertSensor
DisplayString,
alertSensorValue
INTEGER,
alertThreshold
INTEGER,
alertThresholdType
INTEGER,
alertStatus
INTEGER
}
alertIndex OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The index of the alert entry 1..32"
::= { alertEntry 1 }
alertEnabled OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Shows if alert is enabled 0..1"
::= { alertEntry 2 }
alertSensor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Alert Sensor Description"
::= { alertEntry 3 }
alertSensorValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the sensor for analog sensors or open/closed for digital inputs"
::= { alertEntry 4 }
alertThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the alert threshold for analog sensors, irrelevant for alerts for digital inputs"
::= { alertEntry 5 }
alertThresholdType OBJECT-TYPE
SYNTAX INTEGER { lessThan(0), greaterThan(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of the alert threshold for analog sensors, irrelevant for alerts for digital inputs"
::= { alertEntry 6 }
alertStatus OBJECT-TYPE
SYNTAX INTEGER { normal(0), enteringCritical(1), critical(2), exitingCritical(3), waitingAckDismiss(4), acknowledged(5), dismissed(6), disconnected(7) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current status of the alert"
::= { alertEntry 7 }
-- smart alerts description
smAlertTable OBJECT-TYPE
SYNTAX SEQUENCE OF SmAlertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of alert entries"
::= { smAlerts 1 }
smAlertEntry OBJECT-TYPE
SYNTAX SmAlertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A smart alert entry"
INDEX { smAlertIndex }
::= { smAlertTable 1 }
SmAlertEntry ::=
SEQUENCE {
smAlertIndex
Integer32,
smAlertEnabled
Integer32,
smAlertStatus
INTEGER
}
smAlertIndex OBJECT-TYPE
SYNTAX Integer32 (1..1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The index of the alert entry (only one)"
::= { smAlertEntry 1 }
smAlertEnabled OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Shows if alert is enabled 0..1"
::= { smAlertEntry 2 }
smAlertStatus OBJECT-TYPE
SYNTAX INTEGER { normal(0), enteringCritical(1), critical(2), exitingCritical(3), waitingAckDismiss(4), acknowledged(5), dismissed(6), disconnected(7) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current status of the alert"
::= { smAlertEntry 3 }
-- hostSystem subtree
unitName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Unit Name"
::= { hostSystem 1 }
deviceModel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device Model"
::= { hostSystem 2 }
serialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial Number"
::= { hostSystem 3 }
firmwareRevision OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Firmware Revision"
::= { hostSystem 4 }
senderEmailAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "FROM email address for alerts"
::= { hostSystem 5 }
-- Trap Definitions
intSensorsTraps OBJECT IDENTIFIER ::= { enviromuxMicroTraps 1 }
extSensorsTraps OBJECT IDENTIFIER ::= { enviromuxMicroTraps 2 }
digitalInputsTraps OBJECT IDENTIFIER ::= { enviromuxMicroTraps 3 }
ipDevicesTraps OBJECT IDENTIFIER ::= { enviromuxMicroTraps 4 }
intSensor1Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, intSensorValue, intSensorUnit }
STATUS current
DESCRIPTION "Trap issued when internal sensor 1 has a notification to send"
::= {intSensorsTraps 1 }
intSensor2Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, intSensorValue, intSensorUnit }
STATUS current
DESCRIPTION "Trap issued when internal sensor 2 has a notification to send"
::= {intSensorsTraps 2 }
intSensor3Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, intSensorValue, intSensorUnit }
STATUS current
DESCRIPTION "Trap issued when internal sensor 3 has a notification to send"
::= {intSensorsTraps 3 }
extSensor1Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, extSensorValue, extSensorUnit }
STATUS current
DESCRIPTION "Trap issued when external sensor 1 has a notification to send"
::= {extSensorsTraps 1 }
extSensor2Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, extSensorValue, extSensorUnit }
STATUS current
DESCRIPTION "Trap issued when external sensor 2 has a notification to send"
::= {extSensorsTraps 2 }
extSensor3Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, extSensorValue, extSensorUnit }
STATUS current
DESCRIPTION "Trap issued when external sensor 3 has a notification to send"
::= {extSensorsTraps 3 }
extSensor4Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, extSensorValue, extSensorUnit }
STATUS current
DESCRIPTION "Trap issued when external sensor 4 has a notification to send"
::= {extSensorsTraps 4 }
extSensor5Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, extSensorValue, extSensorUnit }
STATUS current
DESCRIPTION "Trap issued when external sensor 5 has a notification to send"
::= {extSensorsTraps 5 }
extSensor6Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, extSensorValue, extSensorUnit }
STATUS current
DESCRIPTION "Trap issued when external sensor 6 has a notification to send"
::= {extSensorsTraps 6 }
digInput1Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, digInputValue }
STATUS current
DESCRIPTION "Trap issued when digital input 1 has a notification to send"
::= {digitalInputsTraps 1 }
digInpu21Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, digInputValue }
STATUS current
DESCRIPTION "Trap issued when digital input 2 has a notification to send"
::= {digitalInputsTraps 2 }
ipDevice1Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, ipDeviceValue }
STATUS current
DESCRIPTION "Trap issued when IP device 1 has a notification to send"
::= {ipDevicesTraps 1 }
ipDevice2Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, ipDeviceValue }
STATUS current
DESCRIPTION "Trap issued when IP device 2 has a notification to send"
::= {ipDevicesTraps 2 }
ipDevice3Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, ipDeviceValue }
STATUS current
DESCRIPTION "Trap issued when IP device 3 has a notification to send"
::= {ipDevicesTraps 3 }
ipDevice4Trap NOTIFICATION-TYPE
OBJECTS { alertStatus, ipDeviceValue }
STATUS current
DESCRIPTION "Trap issued when IP device 4 has a notification to send"
::= {ipDevicesTraps 4 }
END