-- == OG-DATA-MIB: ==
-- == Opengear Data Usage status notification Management Information Base ==
-- == ==
-- == (c) Copyright 2005-2014 Opengear Inc. ==
-- =====================================================================
OG-DATA-MIB DEFINITIONS ::= BEGIN
IMPORTS
ogMgmt
FROM OG-SMI-MIB
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
FROM SNMPv2-CONF
DisplayString
FROM SNMPv2-TC;
ogDataMib MODULE-IDENTITY
LAST-UPDATED "201308110000Z"
ORGANIZATION "Opengear Inc."
CONTACT-INFO
"Opengear Inc.
630 West 9560 South,
Sandy, UT 84070
support@opengear.com"
DESCRIPTION
"Opengear data logging status MIB"
REVISION "201308110000Z"
DESCRIPTION
"Renamed from OPENGEAR-DATA-MIB to OG-DATA-MIB to
fix naming discrepancy."
REVISION "201101302110Z"
DESCRIPTION
"Initial version."
::= { ogMgmt 17 }
ogDataMibObjects OBJECT IDENTIFIER ::= { ogDataMib 10 }
-- Subgroups
ogdataEvent OBJECT IDENTIFIER ::= { ogDataMibObjects 1 }
ogdataEventTable OBJECT-TYPE
SYNTAX SEQUENCE OF OgDataEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of data logging events generated by this device."
::= { ogdataEvent 1 }
ogdataEventEntry OBJECT-TYPE
SYNTAX OgDataEventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A console connection event occuring at this
device. Each entry is indexed by a message index."
INDEX { ogdataEventIndex }
::= { ogdataEventTable 1 }
OgDataEventEntry ::=
SEQUENCE {
ogdataEventIndex Integer32,
ogdataEventBytes Integer32,
ogdataEventSeconds Integer32,
ogdataEventDevice DisplayString,
ogdataEventState INTEGER
}
ogdataEventIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A monotonically increasing integer for the sole
purpose of indexing messages. When it reaches the
maximum value the agent flushes the table and wraps
the value back to 1."
::= { ogdataEventEntry 1 }
ogdataEventBytes OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes exceeded during the time period"
::= { ogdataEventEntry 10 }
ogdataEventSeconds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time in seconds over which the number of bytes was exceeded"
::= { ogdataEventEntry 11 }
ogdataEventDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique name for the interface the alert occurred on."
::= { ogdataEventEntry 12 }
ogdataEventState OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the data alert."
::= { ogdataEventEntry 13 }
-- notifications
ogDataMibNotificationPrefix OBJECT IDENTIFIER ::= {
ogDataMib 2
}
ogdataMibNotifications OBJECT IDENTIFIER ::= {
ogDataMibNotificationPrefix 0
}
ogdataEventOccurred NOTIFICATION-TYPE
OBJECTS { ogdataEventBytes, ogdataEventSeconds, ogdataEventDevice, ogdataEventState }
STATUS current
DESCRIPTION
"The notification sent when a status event occurs"
::= { ogdataMibNotifications 200 }
-- conformance information
ogDataMibConformance OBJECT IDENTIFIER ::= { ogDataMib 3 }
ogDataMibCompliances OBJECT IDENTIFIER ::= {
ogDataMibConformance 1 }
ogDataMibGroups OBJECT IDENTIFIER ::= {
ogDataMibConformance 2 }
-- compliance statements
ogDataMibCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement
the Opengear Data Logging MIB."
MODULE -- this module
MANDATORY-GROUPS { ogDataMibGroup }
GROUP ogdataNotificationsGroup
DESCRIPTION
"The implementation of this group is
mandatory for those systems where
sensor notification is supported."
::= { ogDataMibCompliances 1 }
-- Units of conformance
ogDataMibGroup OBJECT-GROUP
OBJECTS {
ogdataEventBytes,
ogdataEventSeconds,
ogdataEventDevice,
ogdataEventState
}
STATUS current
DESCRIPTION
"A collection of objects providing the sensor MIB capability."
::= { ogDataMibGroups 1 }
ogdataNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
ogdataEventOccurred
}
STATUS current
DESCRIPTION
"A collection of notification(s) for the data logging system."
::= { ogDataMibGroups 2 }
END