mibs/MIBS/opengear/OG-STATUSv2-MIB

4148 lines
94 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- =====================================================================
-- == OG-STATUSv2-MIB: ==
-- == Opengear status Management Information Base ==
-- == ==
-- == (c) Copyright 2013-2020 Opengear Inc. ==
-- =====================================================================
OG-STATUSv2-MIB DEFINITIONS ::= BEGIN
IMPORTS
opengear
FROM OG-SMI-MIB
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE
FROM SNMPv2-SMI
Integer32, Unsigned32, Counter32, Counter64
FROM SNMPv2-SMI
MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
FROM SNMPv2-CONF
DateAndTime, DisplayString
FROM SNMPv2-TC;
ogStatus2 MODULE-IDENTITY
LAST-UPDATED "202011100000Z"
ORGANIZATION "Opengear Inc."
CONTACT-INFO
"Opengear Inc.
630 West 9560 South, Suite A,
Sandy, UT 84070
support@opengear.com"
DESCRIPTION
"Extended network interface status for failover"
REVISION "202011100000Z"
DESCRIPTION
"Opengear extended status and alert MIB"
REVISION "201702030000Z"
DESCRIPTION
"Add CLI session alert."
REVISION "201608260000Z"
DESCRIPTION
"Correct Power Supply table and values."
REVISION "201401280000Z"
DESCRIPTION
"Initial revision"
::= { opengear 17 }
ogSystem OBJECT IDENTIFIER
::= { ogStatus2 1 }
ogFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current device firmware."
::= { ogSystem 1 }
ogSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current serial number (if applicable)."
::= { ogSystem 2 }
ogSerialPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The devices serial port status table."
::= { ogStatus2 2 }
ogSerialPortEntry OBJECT-TYPE
SYNTAX SerialPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A serial port status entry."
INDEX { ogSerialPortIndex }
::= { ogSerialPortTable 1 }
SerialPortEntry ::= SEQUENCE {
ogSerialPortIndex Integer32,
ogSerialPortLabel DisplayString,
ogSerialPortSpeed Integer32,
ogSerialPortDataBits Integer32,
ogSerialPortParity INTEGER,
ogSerialPortStopBits INTEGER,
ogSerialPortFlowControl INTEGER,
ogSerialPortMode INTEGER,
ogSerialPortLogLevel INTEGER,
ogSerialPortRxBytes Counter64,
ogSerialPortTxBytes Counter64,
ogSerialPortFramingErrors Counter64,
ogSerialPortParityErrors Counter64,
ogSerialPortOverrunErrors Counter64,
ogSerialPortBreaks Counter64,
ogSerialPortDCD INTEGER,
ogSerialPortDTR INTEGER,
ogSerialPortDSR INTEGER,
ogSerialPortCTS INTEGER,
ogSerialPortRTS INTEGER
}
ogSerialPortIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the serial port table of this status"
::= { ogSerialPortEntry 1 }
ogSerialPortLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port descriptive name"
::= { ogSerialPortEntry 2 }
ogSerialPortSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port speed in bits per second"
::= { ogSerialPortEntry 3 }
ogSerialPortDataBits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port character size"
::= { ogSerialPortEntry 4 }
ogSerialPortParity OBJECT-TYPE
SYNTAX INTEGER {
none(1),
odd(2),
even(3),
mark(4),
space(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port parity"
::= { ogSerialPortEntry 5 }
ogSerialPortStopBits OBJECT-TYPE
SYNTAX INTEGER {
one(1),
two(2),
oneAndAHalf(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port number of stop bits"
::= { ogSerialPortEntry 6 }
ogSerialPortFlowControl OBJECT-TYPE
SYNTAX INTEGER {
none(1),
hardware(2),
software(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port flow control type"
::= { ogSerialPortEntry 7 }
ogSerialPortMode OBJECT-TYPE
SYNTAX INTEGER {
none(1),
console(2),
sdt(3),
terminal(4),
bridge(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port operational mode type"
::= { ogSerialPortEntry 8 }
ogSerialPortLogLevel OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
connect(2),
inputAndOutput(3),
inputOnly(4),
outputOnly(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port logging level"
::= { ogSerialPortEntry 9 }
ogSerialPortRxBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port bytes received"
::= { ogSerialPortEntry 10 }
ogSerialPortTxBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port bytes transmitted"
::= { ogSerialPortEntry 11 }
ogSerialPortFramingErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port framing error total."
::= { ogSerialPortEntry 12 }
ogSerialPortParityErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port parity error total."
::= { ogSerialPortEntry 13 }
ogSerialPortOverrunErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port Overrun Error total."
::= { ogSerialPortEntry 14 }
ogSerialPortBreaks OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port break total"
::= { ogSerialPortEntry 15 }
ogSerialPortDCD OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the DCD signal."
::= { ogSerialPortEntry 16 }
ogSerialPortDTR OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the DTR signal."
::= { ogSerialPortEntry 17 }
ogSerialPortDSR OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the DSR signal."
::= { ogSerialPortEntry 18 }
ogSerialPortCTS OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the CTS signal."
::= { ogSerialPortEntry 19 }
ogSerialPortRTS OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the RTS signal."
::= { ogSerialPortEntry 20 }
ogSerialUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's serial port users table."
::= { ogStatus2 3 }
ogSerialUserEntry OBJECT-TYPE
SYNTAX SerialUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A user logged in on the serial port"
INDEX { ogSerialUserIndex }
::= { ogSerialUserTable 1 }
SerialUserEntry ::= SEQUENCE {
ogSerialUserIndex Integer32,
ogSerialUserStartTime DateAndTime,
ogSerialUserPort Integer32,
ogSerialUserLabel DisplayString,
ogSerialUserName DisplayString
}
ogSerialUserIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the serial port active users table"
::= { ogSerialUserEntry 1 }
ogSerialUserStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time and date the user session started."
::= { ogSerialUserEntry 2 }
ogSerialUserPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port number"
::= { ogSerialUserEntry 3 }
ogSerialUserLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The readable label for the serial port."
::= { ogSerialUserEntry 4 }
ogSerialUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the user logged in on the port."
::= { ogSerialUserEntry 5 }
ogHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF HostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of monitored network hosts."
::= { ogStatus2 4 }
ogHostEntry OBJECT-TYPE
SYNTAX HostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A monitored network host."
INDEX { ogHostIndex }
::= { ogHostTable 1 }
HostEntry ::= SEQUENCE {
ogHostIndex Integer32,
ogHostName DisplayString,
ogHostIpV4Address DisplayString,
ogHostIpV6Address DisplayString
}
ogHostIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the network host active users table"
::= { ogHostEntry 1 }
ogHostName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of this monitored network host."
::= { ogHostEntry 2 }
ogHostIpV4Address OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IPv4 Address of this monitored network host."
::= { ogHostEntry 3 }
ogHostIpV6Address OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IPv6 Address of this monitored network host."
::= { ogHostEntry 4 }
ogHostServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF HostServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of services belonging to a monitored host."
::= { ogStatus2 5 }
ogHostServiceEntry OBJECT-TYPE
SYNTAX HostServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A monitored host service."
INDEX { ogHostIndex,
ogHostServiceIndex }
::= { ogHostServiceTable 1 }
HostServiceEntry ::= SEQUENCE {
ogHostServiceIndex Integer32,
ogHostServiceHost OBJECT IDENTIFIER,
ogHostServiceType INTEGER,
ogHostServicePort Unsigned32,
ogHostServiceStatus INTEGER,
ogHostServiceCounter Counter32
}
ogHostServiceIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the RPC outlet table"
::= { ogHostServiceEntry 1 }
ogHostServiceHost OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The monitored host this service belongs to"
::= { ogHostServiceEntry 2 }
ogHostServiceType OBJECT-TYPE
SYNTAX INTEGER {
tcp(1),
udp(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of service this is."
::= { ogHostServiceEntry 3 }
ogHostServicePort OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The TCP Port this service is on."
::= { ogHostServiceEntry 4 }
ogHostServiceStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
available(2),
unavailable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The availabalilty of this service."
::= { ogHostServiceEntry 5 }
ogHostServiceCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of alerts related to this service."
::= { ogHostServiceEntry 6 }
ogHostUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF HostUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's serial port users table."
::= { ogStatus2 6 }
ogHostUserEntry OBJECT-TYPE
SYNTAX HostUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A user logged in on the serial port"
INDEX { ogHostUserIndex }
::= { ogHostUserTable 1 }
HostUserEntry ::= SEQUENCE {
ogHostUserIndex Integer32,
ogHostUserHost OBJECT IDENTIFIER,
ogHostUserStartTime DateAndTime,
ogHostUserAddress DisplayString,
ogHostUserHostName DisplayString,
ogHostUserName DisplayString
}
ogHostUserIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the network host active users table"
::= { ogHostUserEntry 1 }
ogHostUserHost OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The monitored host this user is associated with."
::= { ogHostUserEntry 2 }
ogHostUserStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time the user session started."
::= { ogHostUserEntry 3 }
ogHostUserAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The network host address."
::= { ogHostUserEntry 4 }
ogHostUserHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The network host's host name."
::= { ogHostUserEntry 5 }
ogHostUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The network host's active username."
::= { ogHostUserEntry 6 }
ogWebUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF WebUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's Web Interface users table."
::= { ogStatus2 7 }
ogWebUserEntry OBJECT-TYPE
SYNTAX WebUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A user logged in to the Web Interface"
INDEX { ogWebUserIndex }
::= { ogWebUserTable 1 }
WebUserEntry ::= SEQUENCE {
ogWebUserIndex Integer32,
ogWebUserStartTime DateAndTime,
ogWebUserName DisplayString,
ogWebUserSourceAddress DisplayString,
ogWebUserSourcePort Integer32
}
ogWebUserIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the Web Interface users table"
::= { ogWebUserEntry 1 }
ogWebUserStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The web users session start date and time."
::= { ogWebUserEntry 2 }
ogWebUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The web users active username."
::= { ogWebUserEntry 3 }
ogWebUserSourceAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The web users source address."
::= { ogWebUserEntry 4 }
ogWebUserSourcePort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The web users source tcp port."
::= { ogWebUserEntry 5 }
ogEmdTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This devices temperature monitoring table."
::= { ogStatus2 8 }
ogEmdEntry OBJECT-TYPE
SYNTAX EmdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EMD status entry"
INDEX { ogEmdIndex }
::= { ogEmdTable 1 }
EmdEntry ::= SEQUENCE {
ogEmdIndex Integer32,
ogEmdName DisplayString,
ogEmdDescription DisplayString,
ogEmdEnabled INTEGER,
ogEmdLogEnabled INTEGER,
ogEmdConnectType INTEGER,
ogEmdTemperatureTotal Counter32,
ogEmdHumidityTotal Counter32,
ogEmdDioInputTotal Counter32
}
ogEmdIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the EMD status table"
::= { ogEmdEntry 1 }
ogEmdName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the EMD device."
::= { ogEmdEntry 2 }
ogEmdDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the EMD device."
::= { ogEmdEntry 3 }
ogEmdEnabled OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The enabled status of the EMD"
::= { ogEmdEntry 4 }
ogEmdLogEnabled OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The logging status of the EMD"
::= { ogEmdEntry 5 }
ogEmdConnectType OBJECT-TYPE
SYNTAX INTEGER {
internal(1),
serial(2),
network(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How the EMD device is connected."
::= { ogEmdEntry 6 }
ogEmdTemperatureTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of temperature sensors contained in this EMD."
::= { ogEmdEntry 7 }
ogEmdHumidityTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of humidity sensors contained in this EMD."
::= { ogEmdEntry 8 }
ogEmdDioInputTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of DIOs contained in this EMD."
::= { ogEmdEntry 9 }
ogEmdTemperatureTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmdTemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of temperature sensors belonging to EMDs"
::= { ogStatus2 9 }
ogEmdTemperatureEntry OBJECT-TYPE
SYNTAX EmdTemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EMD status entry"
INDEX { ogEmdIndex,
ogEmdTemperatureIndex }
::= { ogEmdTemperatureTable 1 }
EmdTemperatureEntry ::= SEQUENCE {
ogEmdTemperatureIndex Integer32,
ogEmdTemperatureEmd OBJECT IDENTIFIER,
ogEmdTemperatureName DisplayString,
ogEmdTemperatureDescription DisplayString,
ogEmdTemperatureValue Integer32,
ogEmdTemperatureCounter Counter32
}
ogEmdTemperatureIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the EMD status table"
::= { ogEmdTemperatureEntry 1 }
ogEmdTemperatureEmd OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The EMD this temperature sensor is related to."
::= { ogEmdTemperatureEntry 2 }
ogEmdTemperatureName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the EMD temperature sensor."
::= { ogEmdTemperatureEntry 3 }
ogEmdTemperatureDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the EMD device."
::= { ogEmdTemperatureEntry 4 }
ogEmdTemperatureValue OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current temperature reading on the EMD."
::= { ogEmdTemperatureEntry 5 }
ogEmdTemperatureCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of alerts triggered on the EMD."
::= { ogEmdTemperatureEntry 6 }
ogEmdHumidityTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmdHumidityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of humidity sensors belonging to EMDs."
::= { ogStatus2 10 }
ogEmdHumidityEntry OBJECT-TYPE
SYNTAX EmdHumidityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EMD Humidity sensor status entry."
INDEX { ogEmdIndex,
ogEmdHumidityIndex }
::= { ogEmdHumidityTable 1 }
EmdHumidityEntry ::= SEQUENCE {
ogEmdHumidityIndex Integer32,
ogEmdHumidityEmd OBJECT IDENTIFIER,
ogEmdHumidityName DisplayString,
ogEmdHumidityDescription DisplayString,
ogEmdHumidityValue Integer32,
ogEmdHumidityCounter Counter32
}
ogEmdHumidityIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the EMD status table"
::= { ogEmdHumidityEntry 1 }
ogEmdHumidityEmd OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The EMD this humidity sensor is related to."
::= { ogEmdHumidityEntry 2 }
ogEmdHumidityName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the EMD."
::= { ogEmdHumidityEntry 3 }
ogEmdHumidityDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the EMD device."
::= { ogEmdHumidityEntry 4 }
ogEmdHumidityValue OBJECT-TYPE
SYNTAX Integer32
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current humidity value on the EMD"
::= { ogEmdHumidityEntry 5 }
ogEmdHumidityCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of alerts triggered on the EMD"
::= { ogEmdHumidityEntry 6 }
ogEmdDioTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmdDioEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ths Digital I/O status table."
::= { ogStatus2 11 }
ogEmdDioEntry OBJECT-TYPE
SYNTAX EmdDioEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Digital I/O status entry"
INDEX { ogEmdIndex,
ogEmdDioIndex }
::= { ogEmdDioTable 1 }
EmdDioEntry ::= SEQUENCE {
ogEmdDioIndex Integer32,
ogEmdDioEmd OBJECT IDENTIFIER,
ogEmdDioName DisplayString,
ogEmdDioDescription DisplayString,
ogEmdDioType INTEGER,
ogEmdDioDirection INTEGER,
ogEmdDioState INTEGER,
ogEmdDioTriggerMode INTEGER,
ogEmdDioCounter Counter32
}
ogEmdDioIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the Digital I/O status table"
::= { ogEmdDioEntry 1 }
ogEmdDioEmd OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The EMD this Digital I/O relates to."
::= { ogEmdDioEntry 2 }
ogEmdDioName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of this Digital I/O."
::= { ogEmdDioEntry 3 }
ogEmdDioDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of this Digital I/O."
::= { ogEmdDioEntry 4 }
ogEmdDioType OBJECT-TYPE
SYNTAX INTEGER {
ttlInputOutput(1),
highVoltageOutput(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Digital I/O type (TTL Input/Output or High-Voltage Output)."
::= { ogEmdDioEntry 5 }
ogEmdDioDirection OBJECT-TYPE
SYNTAX INTEGER {
output(1),
input(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of the Digital I/O (Input or Output)"
::= { ogEmdDioEntry 6 }
ogEmdDioState OBJECT-TYPE
SYNTAX INTEGER {
high(1),
low(2),
unavailable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The electrical state value of the Digital I/O (Low or High)"
::= { ogEmdDioEntry 7 }
ogEmdDioTriggerMode OBJECT-TYPE
SYNTAX INTEGER {
invalid(1),
risingEdge(2),
fallingEdge(3),
risingFallingEdge(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Trigger Mode of the Digital I/O"
::= { ogEmdDioEntry 8 }
ogEmdDioCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The trigger counter of this Digital I/O"
::= { ogEmdDioEntry 9 }
ogNetInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF NetInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This devices network interface status table."
::= { ogStatus2 12 }
ogNetInterfaceEntry OBJECT-TYPE
SYNTAX NetInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EMD status entry"
INDEX { ogNetInterfaceIndex }
::= { ogNetInterfaceTable 1 }
NetInterfaceEntry ::= SEQUENCE {
ogNetInterfaceIndex Integer32,
ogNetInterfaceName DisplayString,
ogNetInterfaceType INTEGER,
ogNetInterfaceState INTEGER,
ogNetInterfaceFailoverState INTEGER
}
ogNetInterfaceIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the network interface status table"
::= { ogNetInterfaceEntry 1 }
ogNetInterfaceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of a network interface."
::= { ogNetInterfaceEntry 2 }
ogNetInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
ethernet(2),
wifi(3),
cellModem(4),
v92Modem(5),
vpn(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of this network interface entry."
::= { ogNetInterfaceEntry 3 }
ogNetInterfaceState OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
down(2),
starting(3),
up(4),
stopping(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of this network interface entry."
::= { ogNetInterfaceEntry 4 }
ogNetInterfaceFailoverState OBJECT-TYPE
SYNTAX INTEGER {
active(1),
failed(2),
dormant(3),
standby(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The failover status of this interface.
The primary interface is either active or failed.
The secondary interface is either standby, dormant or active."
::= { ogNetInterfaceEntry 5 }
ogPowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's Power Supply table."
::= { ogStatus2 13 }
ogPowerSupplyEntry OBJECT-TYPE
SYNTAX PowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Power Supply status entry"
INDEX { ogPowerSupplyIndex }
::= { ogPowerSupplyTable 1 }
PowerSupplyEntry ::= SEQUENCE {
ogPowerSupplyIndex Integer32,
ogPowerSupplyName DisplayString,
ogPowerSupplyInputVoltage Integer32,
ogPowerSupplyOutputCurrent Integer32,
ogPowerSupplyTemperature Integer32
}
ogPowerSupplyIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the Power Supply status table"
::= { ogPowerSupplyEntry 1 }
ogPowerSupplyName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the Power Supply."
::= { ogPowerSupplyEntry 2 }
ogPowerSupplyInputVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input voltage of the Power Supply"
::= { ogPowerSupplyEntry 3 }
ogPowerSupplyOutputCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output current of the Power Supply"
::= { ogPowerSupplyEntry 4 }
ogPowerSupplyTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of the Power Supply"
::= { ogPowerSupplyEntry 5 }
ogUpsTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ths Uninterruptable Power Supply (UPS) status table."
::= { ogStatus2 14 }
ogUpsEntry OBJECT-TYPE
SYNTAX UpsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Digital I/O status entry"
INDEX { ogUpsIndex }
::= { ogUpsTable 1 }
UpsEntry ::= SEQUENCE {
ogUpsIndex Integer32,
ogUpsName DisplayString,
ogUpsDescription DisplayString,
ogUpsType DisplayString,
ogUpsLogEnabled INTEGER,
ogUpsConnectType INTEGER,
ogUpsState INTEGER,
ogUpsTemperature Integer32,
ogUpsHumidity Integer32,
ogUpsBatteryState INTEGER,
ogUpsBatteryRunTime Integer32,
ogUpsBatteryRunTimeLow Integer32,
ogUpsBatteryRunTimeRestart Integer32,
ogUpsBatteryCharge Integer32,
ogUpsBatteryVoltage Integer32,
ogUpsBatteryNominalVoltage Integer32,
ogUpsBatteryCurrent Integer32,
ogUpsBatteryNominalCurrent Integer32,
ogUpsBatteryTemperature Integer32,
ogUpsInputFrequency Integer32,
ogUpsInputNominalFrequency Integer32,
ogUpsInputVoltage Integer32,
ogUpsInputNominalVoltage Integer32,
ogUpsInputCurrent Integer32,
ogUpsInputNominalCurrent Integer32,
ogUpsOutputFrequency Integer32,
ogUpsOutputNominalFrequency Integer32,
ogUpsOutputVoltage Integer32,
ogUpsOutputNominalVoltage Integer32,
ogUpsOutputCurrent Integer32,
ogUpsOutputNominalCurrent Integer32,
ogUpsOutputLoad Integer32,
ogUpsOutputPower Integer32,
ogUpsOutputTruePower Integer32,
ogUpsCounter Counter32
}
ogUpsIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the UPS status table."
::= { ogUpsEntry 1 }
ogUpsName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of this UPS."
::= { ogUpsEntry 2 }
ogUpsDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of this UPS."
::= { ogUpsEntry 3 }
ogUpsType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UPS driver type."
::= { ogUpsEntry 4 }
ogUpsLogEnabled OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The logging status of the UPS"
::= { ogUpsEntry 5 }
ogUpsConnectType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
usb(2),
http(3),
https(4),
snmp(5),
serial(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How the UPS device is being monitored."
::= { ogUpsEntry 6 }
ogUpsState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
onLine(2),
onBattery(3),
lowBattery(4),
onBypass(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state the UPS is running in."
::= { ogUpsEntry 7 }
ogUpsTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UPS temperature. Negative if unavailable."
::= { ogUpsEntry 8 }
ogUpsHumidity OBJECT-TYPE
SYNTAX Integer32
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UPS humidity. Negative if unavailable."
::= { ogUpsEntry 9 }
ogUpsBatteryState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
normal(2),
warning(3),
low(4),
depleted(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the UPS battery."
::= { ogUpsEntry 10 }
ogUpsBatteryRunTime OBJECT-TYPE
SYNTAX Integer32 (-1..31449600)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery runtime (seconds). Negative if unavailable"
::= { ogUpsEntry 11 }
ogUpsBatteryRunTimeLow OBJECT-TYPE
SYNTAX Integer32 (-1..31449600)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated remaining battery runtime when UPS switches to Low
Battery. Negative if unavailable."
::= { ogUpsEntry 12 }
ogUpsBatteryRunTimeRestart OBJECT-TYPE
SYNTAX Integer32 (-1..31449600)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum battery runtime for UPS restart after power-off
(seconds). Negative if unavailable."
::= { ogUpsEntry 13 }
ogUpsBatteryCharge OBJECT-TYPE
SYNTAX Integer32 (-1..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated percent of Battery charge remaining. Negative if
unavailable."
::= { ogUpsEntry 14 }
ogUpsBatteryVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Volt DC"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The magnitude of the current battery voltage. Negative if
unavailable."
::= { ogUpsEntry 15 }
ogUpsBatteryNominalVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Volt DC"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nominal battery voltage (V). Negative if unavailable."
::= { ogUpsEntry 16 }
ogUpsBatteryCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Amp DC"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UPS battery current. Negative if unavailable."
::= { ogUpsEntry 17 }
ogUpsBatteryNominalCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Amp DC"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal UPS battery current. Negative if unavailable."
::= { ogUpsEntry 18 }
ogUpsBatteryTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UPS battery temperature. Negative if unavailable."
::= { ogUpsEntry 19 }
ogUpsInputFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "Hz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input line frequency (Hz). Negative if unavailable."
::= { ogUpsEntry 20 }
ogUpsInputNominalFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "Hz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nominal input line frequency (Hz). Negative if unavailable."
::= { ogUpsEntry 21 }
ogUpsInputVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The magnitude of the UPS input voltage. Negative if
unavailable."
::= { ogUpsEntry 22 }
ogUpsInputNominalVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal input voltage. Negative if unavailable."
::= { ogUpsEntry 23 }
ogUpsInputCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 RMS Amp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The input current. Negative if unavailable."
::= { ogUpsEntry 24 }
ogUpsInputNominalCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 RMS Amp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal input current. Negative if unavailable."
::= { ogUpsEntry 25 }
ogUpsOutputFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "Hz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output line frequency (Hz). Negative if unavailable."
::= { ogUpsEntry 26 }
ogUpsOutputNominalFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "Hz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nominal output line frequency (Hz). Negative if unavailable."
::= { ogUpsEntry 27 }
ogUpsOutputVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The magnitude of the UPS output voltage. Negative if
unavailable."
::= { ogUpsEntry 28 }
ogUpsOutputNominalVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal magnitude of the UPS output voltage. Negative if
unavailable."
::= { ogUpsEntry 29 }
ogUpsOutputCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 RMS Amp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The magnitude of the UPS input current. Negative if
unavailable."
::= { ogUpsEntry 30 }
ogUpsOutputNominalCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 RMS Amp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal magnitude of the UPS input current. Negative if
unavailable."
::= { ogUpsEntry 31 }
ogUpsOutputLoad OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated percent of UPS power capacity being used."
::= { ogUpsEntry 32 }
ogUpsOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "Volt-Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current value of apparent power (Volt-Amps).
Negative if unavailable."
::= { ogUpsEntry 33 }
ogUpsOutputTruePower OBJECT-TYPE
SYNTAX Integer32
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current value of real power (Watts).
Negative if unavailable."
::= { ogUpsEntry 34 }
ogUpsCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of alerts triggered on the UPS"
::= { ogUpsEntry 35 }
ogRpcTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's Remote Power Controller (RPC) table."
::= { ogStatus2 15 }
ogRpcEntry OBJECT-TYPE
SYNTAX RpcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RPC status entry"
INDEX { ogRpcIndex }
::= { ogRpcTable 1 }
RpcEntry ::= SEQUENCE {
ogRpcIndex Integer32,
ogRpcName DisplayString,
ogRpcDescription DisplayString,
ogRpcType DisplayString,
ogRpcLogEnabled INTEGER,
ogRpcOutletTotal Counter32,
ogRpcMaxTemperature Integer32,
ogRpcConnectType INTEGER,
ogRpcInputFrequency Integer32,
ogRpcInputVoltage Integer32,
ogRpcInputCurrent Integer32,
ogRpcCounter Counter32
}
ogRpcIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the RPC status table"
::= { ogRpcEntry 1 }
ogRpcName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the RPC device."
::= { ogRpcEntry 2 }
ogRpcDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description for the RPC device."
::= { ogRpcEntry 3 }
ogRpcType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A type for the RPC device."
::= { ogRpcEntry 4 }
ogRpcLogEnabled OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The logging status of the RPC"
::= { ogRpcEntry 5 }
ogRpcOutletTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of outlets on this RPC"
::= { ogRpcEntry 6 }
ogRpcMaxTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum temperature on the RPC"
::= { ogRpcEntry 7 }
ogRpcConnectType OBJECT-TYPE
SYNTAX INTEGER {
serial(1),
network(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How the RPC device is connected."
::= { ogRpcEntry 8 }
ogRpcInputFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "Hz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input line frequency (Hz). Negative if unavailable."
::= { ogRpcEntry 9 }
ogRpcInputVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "RMS Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The magnitude of the RPC input voltage. Negative if
unavailable."
::= { ogRpcEntry 10 }
ogRpcInputCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 RMS Amp"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The input current. Negative if unavailable."
::= { ogRpcEntry 11 }
ogRpcCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of alerts triggered on the RPC"
::= { ogRpcEntry 12 }
ogRpcOutletTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpcOutletEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This RPC's outlet table."
::= { ogStatus2 16 }
ogRpcOutletEntry OBJECT-TYPE
SYNTAX RpcOutletEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RPC Outlet status entry"
INDEX { ogRpcIndex,
ogRpcOutletIndex }
::= { ogRpcOutletTable 1 }
RpcOutletEntry ::= SEQUENCE {
ogRpcOutletIndex Integer32,
ogRpcOutletRpc OBJECT IDENTIFIER,
ogRpcOutletName DisplayString,
ogRpcOutletState INTEGER,
ogRpcOutletFrequency Integer32,
ogRpcOutletVoltage Integer32,
ogRpcOutletCurrent Integer32,
ogRpcOutletLoad Integer32
}
ogRpcOutletIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the RPC outlet table"
::= { ogRpcOutletEntry 1 }
ogRpcOutletRpc OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RPC this outlet belongs to"
::= { ogRpcOutletEntry 2 }
ogRpcOutletName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the RPC outlet."
::= { ogRpcOutletEntry 3 }
ogRpcOutletState OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
transitioning(3),
unavailable(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power status of the RPC outlet"
::= { ogRpcOutletEntry 4 }
ogRpcOutletFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "Hz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Output line frequency (Hz). Negative if unavailable."
::= { ogRpcOutletEntry 5 }
ogRpcOutletVoltage OBJECT-TYPE
SYNTAX Integer32 (-1..2640)
UNITS "0.01 Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage on this outlet. Negative if unavailable."
::= { ogRpcOutletEntry 6 }
ogRpcOutletCurrent OBJECT-TYPE
SYNTAX Integer32 (-1..25500)
UNITS "0.01 Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current measured on this outlet. Negative if unavailable."
::= { ogRpcOutletEntry 7 }
ogRpcOutletLoad OBJECT-TYPE
SYNTAX Integer32 (-1..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Estimated percent of RPC outlet power capacity being used."
::= { ogRpcOutletEntry 8 }
ogCellModemTable OBJECT-TYPE
SYNTAX SEQUENCE OF CellModemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ths cellular modem status table."
::= { ogStatus2 17 }
ogCellModemEntry OBJECT-TYPE
SYNTAX CellModemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A cellular modem status entry."
INDEX { ogCellModemIndex }
::= { ogCellModemTable 1 }
CellModemEntry ::= SEQUENCE {
ogCellModemIndex Integer32,
ogCellModemVendor DisplayString,
ogCellModemModel DisplayString,
ogCellModemEnabled INTEGER,
ogCellModemConnected INTEGER,
ogCellModemNetwork DisplayString,
ogCellModemRegistered INTEGER,
ogCellModemTower Integer32,
ogCellModemRadioTechnology INTEGER,
ogCellModemApn DisplayString,
ogCellModem3gRssi Integer32,
ogCellModem4gRssi Integer32,
ogCellModemSessionTime Counter32,
ogCellModemSelectedSimCard Counter32,
ogCellModemTemperature Integer32,
ogCellModemCounter Counter32,
ogCellModemIMSI DisplayString
}
ogCellModemIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the cellular modem status entry."
::= { ogCellModemEntry 1 }
ogCellModemVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Manufacturer ID of Cellular Modem."
::= { ogCellModemEntry 2 }
ogCellModemModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Cellular Modem model name."
::= { ogCellModemEntry 3 }
ogCellModemEnabled OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The enabled state of the modem."
::= { ogCellModemEntry 4 }
ogCellModemConnected OBJECT-TYPE
SYNTAX INTEGER {
connected(1),
disconnected(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The connected state of the modem."
::= { ogCellModemEntry 5 }
ogCellModemNetwork OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the network provider."
::= { ogCellModemEntry 6 }
ogCellModemRegistered OBJECT-TYPE
SYNTAX INTEGER {
registered(1),
unregistered(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The registration state of the modem."
::= { ogCellModemEntry 7 }
ogCellModemTower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current cellular tower ID."
::= { ogCellModemEntry 8 }
ogCellModemRadioTechnology OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
cdma(2),
evdo(3),
gsm(4),
umts(5),
lte(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Radio Access Technology being used"
::= { ogCellModemEntry 9 }
ogCellModemApn OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The APN configured for this cellmodem."
::= { ogCellModemEntry 10 }
ogCellModem3gRssi OBJECT-TYPE
SYNTAX Integer32 (-99..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current 3G Received Signal Strength (RSSI) if applicable."
::= { ogCellModemEntry 11 }
ogCellModem4gRssi OBJECT-TYPE
SYNTAX Integer32 (-99..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current 4G Received Signal Strength (RSSI) if applicable."
::= { ogCellModemEntry 12 }
ogCellModemSessionTime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds the modem session has been up for."
::= { ogCellModemEntry 13 }
ogCellModemSelectedSimCard OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SIM card currently being used by this modem."
::= { ogCellModemEntry 14 }
ogCellModemTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current temperature of the Cellular Modem."
::= { ogCellModemEntry 15 }
ogCellModemCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of alerts the modem has triggered."
::= { ogCellModemEntry 16 }
ogCellModemIMSI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IMSI of the SIM currently in use by the Cellular Modem."
::= { ogCellModemEntry 17 }
ogWifiClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF WifiClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ths wireless client status table."
::= { ogStatus2 18 }
ogWifiClientEntry OBJECT-TYPE
SYNTAX WifiClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A wireless client status entry."
INDEX { ogWifiClientIndex }
::= { ogWifiClientTable 1 }
WifiClientEntry ::= SEQUENCE {
ogWifiClientIndex Integer32,
ogWifiClientInterface DisplayString,
ogWifiClientEnabled INTEGER,
ogWifiClientEssid DisplayString,
ogWifiClientIeeeMode INTEGER,
ogWifiClientMode INTEGER,
ogWifiClientFrequency Unsigned32,
ogWifiClientApMac DisplayString,
ogWifiClientBitRate Unsigned32,
ogWifiClientTxPower Integer32,
ogWifiClientLinkQuality Unsigned32,
ogWifiClientRssi Integer32,
ogWifiClientRxInvalidNwid Counter32,
ogWifiClientRxInvalidCrypt Counter32,
ogWifiClientRxInvalidFrag Counter32,
ogWifiClientRxInvalidRetries Counter32,
ogWifiClientRxInvalidMisc Counter32,
ogWifiClientMissedBeacon Counter32,
ogWifiClientCounter Counter32
}
ogWifiClientIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the wireless client status entry."
::= { ogWifiClientEntry 1 }
ogWifiClientInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wireless client network interface name."
::= { ogWifiClientEntry 2 }
ogWifiClientEnabled OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wireless client enabled state"
::= { ogWifiClientEntry 3 }
ogWifiClientEssid OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ESSID this wireless client is currently associated with."
::= { ogWifiClientEntry 4 }
ogWifiClientIeeeMode OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
ieee802Dot11B(2),
ieee802Dot11BG(3),
ieee802Dot11BGN(4),
ieee802Dot11ABGN(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IEEE 802.11 mode of this wireless client."
::= { ogWifiClientEntry 5 }
ogWifiClientMode OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
managed(2),
adhoc(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operating mode of this wireless client."
::= { ogWifiClientEntry 6 }
ogWifiClientFrequency OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.0001 THz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current frequency of this wireless client."
::= { ogWifiClientEntry 7 }
ogWifiClientApMac OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Access Point ID this wireless client is associated with."
::= { ogWifiClientEntry 8 }
ogWifiClientBitRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "Mb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current bit-rate of this wireless client."
::= { ogWifiClientEntry 9 }
ogWifiClientTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Tx-Power of this wireless client."
::= { ogWifiClientEntry 10 }
ogWifiClientLinkQuality OBJECT-TYPE
SYNTAX Unsigned32
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The normalized link quality of this wireless client."
::= { ogWifiClientEntry 11 }
ogWifiClientRssi OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Signal Level of this wireless client."
::= { ogWifiClientEntry 12 }
ogWifiClientRxInvalidNwid OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of invalid Network ID's for this wireless client."
::= { ogWifiClientEntry 13 }
ogWifiClientRxInvalidCrypt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of invalid crypt's for this wireless client."
::= { ogWifiClientEntry 14 }
ogWifiClientRxInvalidFrag OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of invalid frag's for this wireless client."
::= { ogWifiClientEntry 15 }
ogWifiClientRxInvalidRetries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of invalid retries for this wireless client."
::= { ogWifiClientEntry 16 }
ogWifiClientRxInvalidMisc OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of invalid misc's for this wireless client."
::= { ogWifiClientEntry 17 }
ogWifiClientMissedBeacon OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of missed beacon's for this wireless client."
::= { ogWifiClientEntry 18 }
ogWifiClientCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of alerts triggered by this wireless client."
::= { ogWifiClientEntry 19 }
ogWifiApTable OBJECT-TYPE
SYNTAX SEQUENCE OF WifiApEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ths wireless interface status table."
::= { ogStatus2 19 }
ogWifiApEntry OBJECT-TYPE
SYNTAX WifiApEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A wireless interface status entry"
INDEX { ogWifiApIndex }
::= { ogWifiApTable 1 }
WifiApEntry ::= SEQUENCE {
ogWifiApIndex Integer32,
ogWifiApInterface DisplayString,
ogWifiApEnabled INTEGER,
ogWifiApSsid DisplayString,
ogWifiApIeeeMode INTEGER,
ogWifiApFrequency Unsigned32,
ogWifiApTxPower Integer32,
ogWifiApCounter Counter32
}
ogWifiApIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the wireless server status entry."
::= { ogWifiApEntry 1 }
ogWifiApInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wireless access point network interface name."
::= { ogWifiApEntry 2 }
ogWifiApEnabled OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The enabled status of the wireless server."
::= { ogWifiApEntry 3 }
ogWifiApSsid OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SSID for this wireless access point."
::= { ogWifiApEntry 4 }
ogWifiApIeeeMode OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
ieee802Dot11B(2),
ieee802Dot11BG(3),
ieee802Dot11BGN(4),
ieee802Dot11ABGN(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IEEE 802.11 mode of this wireless access point."
::= { ogWifiApEntry 5 }
ogWifiApFrequency OBJECT-TYPE
SYNTAX Unsigned32
UNITS "0.0001 THz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current frequency of this wireless access point."
::= { ogWifiApEntry 6 }
ogWifiApTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Tx-Power of this wireless access point."
::= { ogWifiApEntry 7 }
ogWifiApCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of alerts triggered by this wireless access point."
::= { ogWifiApEntry 8 }
ogWifiApClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF WifiApClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This RPC's outlet table."
::= { ogStatus2 20 }
ogWifiApClientEntry OBJECT-TYPE
SYNTAX WifiApClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RPC Outlet status entry"
INDEX { ogWifiApIndex,
ogWifiApClientIndex }
::= { ogWifiApClientTable 1 }
WifiApClientEntry ::= SEQUENCE {
ogWifiApClientIndex Integer32,
ogWifiApClientAp OBJECT IDENTIFIER,
ogWifiApClientMac DisplayString,
ogWifiApClientInactiveTime Counter32,
ogWifiApClientRxBytes Counter32,
ogWifiApClientRxPackets Counter32,
ogWifiApClientTxBytes Counter32,
ogWifiApClientTxPackets Counter32,
ogWifiApClientRssi Integer32,
ogWifiApClientTxBitRate Unsigned32
}
ogWifiApClientIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the wireless AP client table"
::= { ogWifiApClientEntry 1 }
ogWifiApClientAp OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wireless AP this client is assiciated with."
::= { ogWifiApClientEntry 2 }
ogWifiApClientMac OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of the Access Point this wireless client is associated with."
::= { ogWifiApClientEntry 3 }
ogWifiApClientInactiveTime OBJECT-TYPE
SYNTAX Counter32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Inactive Time for this wireless client."
::= { ogWifiApClientEntry 4 }
ogWifiApClientRxBytes OBJECT-TYPE
SYNTAX Counter32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received bytes for this wireless client."
::= { ogWifiApClientEntry 5 }
ogWifiApClientRxPackets OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets for this wireless client."
::= { ogWifiApClientEntry 6 }
ogWifiApClientTxBytes OBJECT-TYPE
SYNTAX Counter32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted bytes for this wireless client."
::= { ogWifiApClientEntry 7 }
ogWifiApClientTxPackets OBJECT-TYPE
SYNTAX Counter32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted packets for this wireless client."
::= { ogWifiApClientEntry 8 }
ogWifiApClientRssi OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Signal Level of this wireless client."
::= { ogWifiApClientEntry 9 }
ogWifiApClientTxBitRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "Mb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current transmission bit-rate of this wireless client."
::= { ogWifiApClientEntry 10 }
ogCheckTable OBJECT-TYPE
SYNTAX SEQUENCE OF CheckEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ths auto-response check table."
::= { ogStatus2 21 }
ogCheckEntry OBJECT-TYPE
SYNTAX CheckEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An auto-response check entry"
INDEX { ogCheckIndex }
::= { ogCheckTable 1 }
CheckEntry ::= SEQUENCE {
ogCheckIndex Integer32,
ogCheckName DisplayString,
ogCheckRepeatTimeout Integer32,
ogCheckResetTimeout Integer32,
ogCheckType INTEGER,
ogCheckTriggerActions Counter32,
ogCheckResolveActions Counter32
}
ogCheckIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the auto-response rule"
::= { ogCheckEntry 1 }
ogCheckName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of this auto-response rule."
::= { ogCheckEntry 2 }
ogCheckRepeatTimeout OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum seconds before trigger actions can be repeated
for this auto-response."
::= { ogCheckEntry 3 }
ogCheckResetTimeout OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum seconds after resolution before this
auto-response can be triggered again."
::= { ogCheckEntry 4 }
ogCheckType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
serialSignal(2),
serialUser(3),
serialPattern(4),
hostPing(5),
hostService(6),
hostUser(7),
webUser(8),
envTemperature(9),
envHumidity(10),
dioInput(11),
netInterface(12),
powerSupplyInputVoltage(13),
powerSupplyOutputCurrent(14),
powerSupplyTemperature(15),
upsInputVoltage(16),
upsBatteryCharge(17),
upsBatteryTemperature(18),
upsOutputLoad(19),
upsInputFrequency(20),
upsStateOnBattery(21),
upsStateLowBattery(22),
rpcInput(23),
rpcOutletState(24),
rpcOutletOutput(25),
cellMessage(26),
cellData(27),
cellSignal(28),
cellApn(29),
cellTower(30),
cellNetwork(31),
wirelessClientConnect(32),
wirelessClientSignal(33),
wirelessApAssociation(34),
wirelessApAuthentication(35),
dialPoolHealth(36),
cliUser(37),
custom(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auto-response check type"
::= { ogCheckEntry 5 }
ogCheckTriggerActions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Trigger Actions configured for the auto-response."
::= { ogCheckEntry 6 }
ogCheckResolveActions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Resolve Actions configured for the auto-response."
::= { ogCheckEntry 7 }
ogCheckDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF CheckDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The auto-response device reference table."
::= { ogStatus2 22 }
ogCheckDeviceEntry OBJECT-TYPE
SYNTAX CheckDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RPC Outlet status entry"
INDEX { ogCheckIndex,
ogCheckDeviceIndex }
::= { ogCheckDeviceTable 1 }
CheckDeviceEntry ::= SEQUENCE {
ogCheckDeviceIndex Integer32,
ogCheckDeviceCheck OBJECT IDENTIFIER,
ogCheckDeviceName DisplayString,
ogCheckDeviceRef DisplayString
}
ogCheckDeviceIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the auto-response device outlet table"
::= { ogCheckDeviceEntry 1 }
ogCheckDeviceCheck OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The check this device is associated with."
::= { ogCheckDeviceEntry 2 }
ogCheckDeviceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of a device pertaining to the auto-reponse."
::= { ogCheckDeviceEntry 3 }
ogCheckDeviceRef OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reference ID of the device pertaining to the auto-reponse."
::= { ogCheckDeviceEntry 4 }
--
-- The Alarm Group
--
ogAlarm OBJECT IDENTIFIER ::= { ogStatus2 23 }
ogAlarmLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The alarm history table."
::= { ogAlarm 1 }
ogAlarmLogEntry OBJECT-TYPE
SYNTAX AlarmLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An alarm entry."
INDEX { ogAlarmLogIndex }
::= { ogAlarmLogTable 1 }
AlarmLogEntry ::= SEQUENCE {
ogAlarmLogIndex Integer32,
ogAlarmEventId Integer32,
ogAlarmName DisplayString,
ogAlarmCheck Integer32,
ogAlarmInstance Integer32,
ogAlarmTime DateAndTime,
ogAlarmType INTEGER,
ogAlarmSummary DisplayString,
ogAlarmDevice DisplayString,
ogAlarmUser DisplayString,
ogAlarmTriggerValue Integer32,
ogAlarmCurrentValue Integer32,
ogAlarmPreviousValue Integer32,
ogAlarmState INTEGER
}
ogAlarmLogIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the current alarm table of this alarm."
::= { ogAlarmLogEntry 1 }
ogAlarmEventId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique event ID for this alarm."
::= { ogAlarmLogEntry 2 }
ogAlarmName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The check ID that this alarm pertains to."
::= { ogAlarmLogEntry 3 }
ogAlarmCheck OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auto-response index this alarm relates to."
::= { ogAlarmLogEntry 4 }
ogAlarmInstance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reference index for this alarm instance."
::= { ogAlarmLogEntry 5 }
ogAlarmTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UTC date and time for when this alarm was created."
::= { ogAlarmLogEntry 6 }
ogAlarmType OBJECT-TYPE
SYNTAX INTEGER {
serialSignalCts(1),
serialSignalDcd(2),
serialSignalDsr(3),
serialPatternTx(4),
serialPatternRx(5),
serialUserSession(6),
hostPingDown(7),
hostPingUp(8),
hostServiceDown(9),
hostServiceUp(10),
hostUserSession(11),
webUserSession(12),
envTemperatureLow(13),
envTemperatureHigh(14),
envHumidityLow(15),
envHumidityHigh(16),
dioSignalOpened(17),
dioSignalClosed(18),
netInterfaceDown(19),
netInterfaceStarting(20),
netInterfaceUp(21),
netInterfaceStopping(22),
powerSupplyInputVoltageLow(23),
powerSupplyInputVoltageHigh(24),
powerSupplyOutputCurrentLow(25),
powerSupplyOutputCurrentHigh(26),
powerSupplyTemperatureLow(27),
powerSupplyTemperatureHigh(28),
upsTemperatureHigh(29),
upsTemperatureLow(30),
upsHumidityHigh(31),
upsHumidityLow(32),
upsOnBattery(33),
upsLowBattery(34),
upsBatteryChargeLow(35),
upsBatteryChargeHigh(36),
upsBatteryVoltageLow(37),
upsBatteryVoltageHigh(38),
upsBatteryCurrentLow(39),
upsBatteryCurrentHigh(40),
upsBatteryTemperatureLow(41),
upsBatteryTemperatureHigh(42),
upsInputFrequencyLow(43),
upsInputFrequencyHigh(44),
upsInputVoltageLow(45),
upsInputVoltageHigh(46),
upsInputCurrentLow(47),
upsInputCurrentHigh(48),
upsOutputFrequencyLow(49),
upsOutputFrequencyHigh(50),
upsOutputVoltageLow(51),
upsOutputVoltageHigh(52),
upsOutputCurrentLow(53),
upsOutputCurrentHigh(54),
upsOutputLoadLow(55),
upsOutputLoadHigh(56),
upsOutputPowerLow(57),
upsOutputPowerHigh(58),
upsOutputTruePowerLow(59),
upsOutputTruePowerHigh(60),
rpcInputFrequencyLow(61),
rpcInputFrequencyHigh(62),
rpcInputVoltageLow(63),
rpcInputVoltageHigh(64),
rpcInputCurrentLow(65),
rpcInputCurrentHigh(66),
rpcOutletFrequencyHigh(67),
rpcOutletFrequencyLow(68),
rpcOutletVoltageHigh(69),
rpcOutletVoltageLow(70),
rpcOutletCurrentHigh(71),
rpcOutletCurrentLow(72),
rpcOutletStateOff(73),
rpcOutletStateOn(74),
cellDataUsage(75),
cellMessageReceived(76),
cellSignalLow(77),
cellSignalHigh(78),
cellApnChanged(79),
cellTowerChanged(80),
cellNetworkChanged(81),
wirelessClientConnected(82),
wirelessClientDisconnected(83),
wirelessClientSignalLow(84),
wirelessClientSignalHigh(85),
wirelessApAssociation(86),
wirelessApDisassociation(87),
wirelessApAuthenticationFailure(88),
dialPoolHealth(89),
cliUserSession(90),
customCheckFailure(255),
unknown(65535)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to an Alarm Type Object."
::= { ogAlarmLogEntry 7 }
ogAlarmSummary OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The human readable summary of this alarm."
::= { ogAlarmLogEntry 8 }
ogAlarmDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The device ID that this alarm pertains to."
::= { ogAlarmLogEntry 9 }
ogAlarmUser OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user ID that this alarm pertains to."
::= { ogAlarmLogEntry 10 }
ogAlarmTriggerValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The threshold value which triggers the alarm."
::= { ogAlarmLogEntry 11 }
ogAlarmCurrentValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value as of the time of this entry."
::= { ogAlarmLogEntry 12 }
ogAlarmPreviousValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The former value of this entry."
::= { ogAlarmLogEntry 13 }
ogAlarmState OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
triggered(2),
resolving(3),
waiting(4),
disabled(5),
unresolvable(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The effective alarm state."
::= { ogAlarmLogEntry 14 }
ogCurrentAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF CurrentAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The alarm history table."
::= { ogAlarm 2 }
ogCurrentAlarmEntry OBJECT-TYPE
SYNTAX CurrentAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An alarm entry."
INDEX { ogCurrentAlarmIndex }
::= { ogCurrentAlarmTable 1 }
CurrentAlarmEntry ::= SEQUENCE {
ogCurrentAlarmIndex Integer32,
ogCurrentAlarmEventId Integer32,
ogCurrentAlarmName DisplayString,
ogCurrentAlarmCheck Integer32,
ogCurrentAlarmInstance Integer32,
ogCurrentAlarmTime DateAndTime,
ogCurrentAlarmType INTEGER,
ogCurrentAlarmSummary DisplayString,
ogCurrentAlarmDevice DisplayString,
ogCurrentAlarmUser DisplayString,
ogCurrentAlarmTriggerValue Integer32,
ogCurrentAlarmCurrentValue Integer32,
ogCurrentAlarmPreviousValue Integer32,
ogCurrentAlarmState INTEGER
}
ogCurrentAlarmIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the current alarm table of this alarm."
::= { ogCurrentAlarmEntry 1 }
ogCurrentAlarmEventId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique event ID for this alarm."
::= { ogCurrentAlarmEntry 2 }
ogCurrentAlarmName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of the check this alarm pertains to."
::= { ogCurrentAlarmEntry 3 }
ogCurrentAlarmCheck OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auto-response index this alarm relates to."
::= { ogCurrentAlarmEntry 4 }
ogCurrentAlarmInstance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reference index for this alarm instance."
::= { ogCurrentAlarmEntry 5 }
ogCurrentAlarmTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UTC date and time for when this alarm was created."
::= { ogCurrentAlarmEntry 6 }
ogCurrentAlarmType OBJECT-TYPE
SYNTAX INTEGER {
serialSignalCts(1),
serialSignalDcd(2),
serialSignalDsr(3),
serialPatternTx(4),
serialPatternRx(5),
serialUserSession(6),
hostPingDown(7),
hostPingUp(8),
hostServiceDown(9),
hostServiceUp(10),
hostUserSession(11),
webUserSession(12),
envTemperatureLow(13),
envTemperatureHigh(14),
envHumidityLow(15),
envHumidityHigh(16),
dioSignalOpened(17),
dioSignalClosed(18),
netInterfaceDown(19),
netInterfaceStarting(20),
netInterfaceUp(21),
netInterfaceStopping(22),
powerSupplyInputVoltageLow(23),
powerSupplyInputVoltageHigh(24),
powerSupplyOutputCurrentLow(25),
powerSupplyOutputCurrentHigh(26),
powerSupplyTemperatureLow(27),
powerSupplyTemperatureHigh(28),
upsTemperatureHigh(29),
upsTemperatureLow(30),
upsHumidityHigh(31),
upsHumidityLow(32),
upsOnBattery(33),
upsLowBattery(34),
upsBatteryChargeLow(35),
upsBatteryChargeHigh(36),
upsBatteryVoltageLow(37),
upsBatteryVoltageHigh(38),
upsBatteryCurrentLow(39),
upsBatteryCurrentHigh(40),
upsBatteryTemperatureLow(41),
upsBatteryTemperatureHigh(42),
upsInputFrequencyLow(43),
upsInputFrequencyHigh(44),
upsInputVoltageLow(45),
upsInputVoltageHigh(46),
upsInputCurrentLow(47),
upsInputCurrentHigh(48),
upsOutputFrequencyLow(49),
upsOutputFrequencyHigh(50),
upsOutputVoltageLow(51),
upsOutputVoltageHigh(52),
upsOutputCurrentLow(53),
upsOutputCurrentHigh(54),
upsOutputLoadLow(55),
upsOutputLoadHigh(56),
upsOutputPowerLow(57),
upsOutputPowerHigh(58),
upsOutputTruePowerLow(59),
upsOutputTruePowerHigh(60),
rpcInputFrequencyLow(61),
rpcInputFrequencyHigh(62),
rpcInputVoltageLow(63),
rpcInputVoltageHigh(64),
rpcInputCurrentLow(65),
rpcInputCurrentHigh(66),
rpcOutletFrequencyHigh(67),
rpcOutletFrequencyLow(68),
rpcOutletVoltageHigh(69),
rpcOutletVoltageLow(70),
rpcOutletCurrentHigh(71),
rpcOutletCurrentLow(72),
rpcOutletStateOff(73),
rpcOutletStateOn(74),
cellDataUsage(75),
cellMessageReceived(76),
cellSignalLow(77),
cellSignalHigh(78),
cellApnChanged(79),
cellTowerChanged(80),
cellNetworkChanged(81),
wirelessClientConnected(82),
wirelessClientDisconnected(83),
wirelessClientSignalLow(84),
wirelessClientSignalHigh(85),
wirelessApAssociation(86),
wirelessApDisassociation(87),
wirelessApAuthenticationFailure(88),
dialPoolHealth(89),
cliUserSession(90),
customCheckFailure(255),
unknown(65535)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The specific Alarm Type."
::= { ogCurrentAlarmEntry 7 }
ogCurrentAlarmSummary OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A readable summary of this alarm."
::= { ogCurrentAlarmEntry 8 }
ogCurrentAlarmDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of the device this alarm pertains to."
::= { ogCurrentAlarmEntry 9 }
ogCurrentAlarmUser OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of the user this alarm pertains to."
::= { ogCurrentAlarmEntry 10 }
ogCurrentAlarmTriggerValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The threshold value which triggers the alarm."
::= { ogCurrentAlarmEntry 11 }
ogCurrentAlarmCurrentValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value as of the time of this entry."
::= { ogCurrentAlarmEntry 12 }
ogCurrentAlarmPreviousValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The former value of this entry."
::= { ogCurrentAlarmEntry 13 }
ogCurrentAlarmState OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
triggered(2),
resolving(3),
waiting(4),
disabled(5),
unresolvable(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The effective alarm state."
::= { ogCurrentAlarmEntry 14 }
-- Notifications
ogStatus2NotificationPrefix OBJECT IDENTIFIER ::= {
ogStatus2 100
}
ogMibNotifications OBJECT IDENTIFIER ::= {
ogStatus2NotificationPrefix 0
}
ogSerialSignalNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a serial signal changes."
::= { ogMibNotifications 1 }
ogSerialPatternNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a pattern is matched on a serial
port ."
::= { ogMibNotifications 2 }
ogSerialUserNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a user logs in or out of a serial
console."
::= { ogMibNotifications 3 }
ogHostPingNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a host stops or resumes responding
to a ping."
::= { ogMibNotifications 4 }
ogHostServiceNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a host service stops or resumes."
::= { ogMibNotifications 5 }
ogHostUserNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a user logs in or out of a network
host."
::= { ogMibNotifications 6 }
ogWebUserNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a user logs in or out of the web
interface."
::= { ogMibNotifications 7 }
ogEmdTemperatureNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a temperature event occurs"
::= { ogMibNotifications 8 }
ogEmdHumidityNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a humidity event occurs"
::= { ogMibNotifications 9 }
ogEmdDioNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a Digital I/O input event occurs"
::= { ogMibNotifications 10 }
ogPowerSupplyInputNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a power supply voltage alarm occurs"
::= { ogMibNotifications 11 }
ogPowerSupplyOutputNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a power supply voltage alarm occurs"
::= { ogMibNotifications 12 }
ogPowerSupplyTempNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a power supply voltage alarm occurs"
::= { ogMibNotifications 13 }
ogUpsNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a UPS alarm occurs"
::= { ogMibNotifications 14 }
ogUpsBatteryNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a UPS battery alarm occurs"
::= { ogMibNotifications 15 }
ogUpsInputNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a UPS input alarm occurs"
::= { ogMibNotifications 16 }
ogUpsOutputNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a UPS output alarm occurs"
::= { ogMibNotifications 17 }
ogRpcInputNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a RPC input alarm occurs"
::= { ogMibNotifications 18 }
ogRpcOutputNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a RPC output alarm occurs"
::= { ogMibNotifications 19 }
ogRpcOutletNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a RPC output alarm occurs"
::= { ogMibNotifications 20 }
ogNetInterfaceNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a network interface event occurs."
::= { ogMibNotifications 21 }
ogCellDataNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a cellular data alarm occurs."
::= { ogMibNotifications 22 }
ogCellMessageNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when an SMS command alarm occurs."
::= { ogMibNotifications 23 }
ogCellSignalNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a cellular signal alarm occurs."
::= { ogMibNotifications 24 }
ogCellApnNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a cellular APN alarm occurs."
::= { ogMibNotifications 25 }
ogCellTowerNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a cellular tower alarm occurs."
::= { ogMibNotifications 26 }
ogCellNetworkNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a cellular network alarm occurs."
::= { ogMibNotifications 27 }
ogWifiClientConnectNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a wireless client connects or
disconnects."
::= { ogMibNotifications 28 }
ogWifiClientSignalNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a wireless client signal changes."
::= { ogMibNotifications 29 }
ogWifiApAssociationNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a wireless client connects or
disconnects to this AP."
::= { ogMibNotifications 30 }
ogWifiApAuthNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a wireless client fails to
authenticate with this AP."
::= { ogMibNotifications 31 }
ogDialPoolHealthNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when dial-pool health alarm occurs."
::= { ogMibNotifications 32 }
ogCustomNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a custom check is triggered."
::= { ogMibNotifications 33 }
ogCliUserSessionNotification NOTIFICATION-TYPE
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState
}
STATUS current
DESCRIPTION
"The notification sent when a user logs in or out of a CLI
session."
::= { ogMibNotifications 34 }
-- End notifications
-- conformance information
ogStatus2Conformance OBJECT IDENTIFIER ::= { ogStatus2 65535 }
ogStatus2Compliances OBJECT IDENTIFIER ::= {
ogStatus2Conformance 1 }
ogStatus2Groups OBJECT IDENTIFIER ::= {
ogStatus2Conformance 2 }
-- compliance statements
ogStatus2Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the Opengear status MIB."
MODULE -- this module
MANDATORY-GROUPS {
ogBasicStatusGroup,
ogBasicAlarmGroup,
ogBasicNotificationGroup
}
::= { ogStatus2Compliances 1 }
-- units of conformance
ogBasicStatusGroup OBJECT-GROUP
OBJECTS {
ogFirmwareVersion,
ogSerialNumber,
ogSerialPortLabel,
ogSerialPortSpeed,
ogSerialPortDataBits,
ogSerialPortParity,
ogSerialPortStopBits,
ogSerialPortFlowControl,
ogSerialPortMode,
ogSerialPortLogLevel,
ogSerialPortRxBytes,
ogSerialPortTxBytes,
ogSerialPortFramingErrors,
ogSerialPortParityErrors,
ogSerialPortOverrunErrors,
ogSerialPortBreaks,
ogSerialPortDCD,
ogSerialPortDTR,
ogSerialPortDSR,
ogSerialPortCTS,
ogSerialPortRTS,
ogSerialUserStartTime,
ogSerialUserPort,
ogSerialUserLabel,
ogSerialUserName,
ogHostName,
ogHostIpV4Address,
ogHostIpV6Address,
ogHostServiceHost,
ogHostServiceType,
ogHostServicePort,
ogHostServiceStatus,
ogHostServiceCounter,
ogHostUserHost,
ogHostUserStartTime,
ogHostUserAddress,
ogHostUserHostName,
ogHostUserName,
ogWebUserStartTime,
ogWebUserName,
ogWebUserSourceAddress,
ogWebUserSourcePort,
ogEmdName,
ogEmdDescription,
ogEmdEnabled,
ogEmdLogEnabled,
ogEmdConnectType,
ogEmdTemperatureTotal,
ogEmdHumidityTotal,
ogEmdDioInputTotal,
ogEmdTemperatureEmd,
ogEmdTemperatureName,
ogEmdTemperatureDescription,
ogEmdTemperatureValue,
ogEmdTemperatureCounter,
ogEmdHumidityEmd,
ogEmdHumidityName,
ogEmdHumidityDescription,
ogEmdHumidityValue,
ogEmdHumidityCounter,
ogEmdDioEmd,
ogEmdDioName,
ogEmdDioDescription,
ogEmdDioType,
ogEmdDioDirection,
ogEmdDioState,
ogEmdDioTriggerMode,
ogEmdDioCounter,
ogNetInterfaceName,
ogNetInterfaceType,
ogNetInterfaceState,
ogNetInterfaceFailoverState,
ogPowerSupplyName,
ogPowerSupplyInputVoltage,
ogPowerSupplyOutputCurrent,
ogPowerSupplyTemperature,
ogUpsName,
ogUpsDescription,
ogUpsType,
ogUpsLogEnabled,
ogUpsConnectType,
ogUpsState,
ogUpsTemperature,
ogUpsHumidity,
ogUpsBatteryState,
ogUpsBatteryRunTime,
ogUpsBatteryRunTimeLow,
ogUpsBatteryRunTimeRestart,
ogUpsBatteryCharge,
ogUpsBatteryVoltage,
ogUpsBatteryNominalVoltage,
ogUpsBatteryCurrent,
ogUpsBatteryNominalCurrent,
ogUpsBatteryTemperature,
ogUpsInputFrequency,
ogUpsInputNominalFrequency,
ogUpsInputVoltage,
ogUpsInputNominalVoltage,
ogUpsInputCurrent,
ogUpsInputNominalCurrent,
ogUpsOutputFrequency,
ogUpsOutputNominalFrequency,
ogUpsOutputVoltage,
ogUpsOutputNominalVoltage,
ogUpsOutputCurrent,
ogUpsOutputNominalCurrent,
ogUpsOutputLoad,
ogUpsOutputPower,
ogUpsOutputTruePower,
ogUpsCounter,
ogRpcName,
ogRpcDescription,
ogRpcType,
ogRpcLogEnabled,
ogRpcOutletTotal,
ogRpcMaxTemperature,
ogRpcConnectType,
ogRpcInputFrequency,
ogRpcInputVoltage,
ogRpcInputCurrent,
ogRpcCounter,
ogRpcOutletRpc,
ogRpcOutletName,
ogRpcOutletState,
ogRpcOutletFrequency,
ogRpcOutletCurrent,
ogRpcOutletVoltage,
ogRpcOutletLoad,
ogCellModemVendor,
ogCellModemModel,
ogCellModemEnabled,
ogCellModemConnected,
ogCellModemNetwork,
ogCellModemRegistered,
ogCellModemTower,
ogCellModemRadioTechnology,
ogCellModemApn,
ogCellModem3gRssi,
ogCellModem4gRssi,
ogCellModemSessionTime,
ogCellModemSelectedSimCard,
ogCellModemTemperature,
ogCellModemCounter,
ogCellModemIMSI,
ogWifiClientInterface,
ogWifiClientEnabled,
ogWifiClientEssid,
ogWifiClientIeeeMode,
ogWifiClientMode,
ogWifiClientFrequency,
ogWifiClientApMac,
ogWifiClientBitRate,
ogWifiClientTxPower,
ogWifiClientLinkQuality,
ogWifiClientRssi,
ogWifiClientRxInvalidNwid,
ogWifiClientRxInvalidCrypt,
ogWifiClientRxInvalidFrag,
ogWifiClientRxInvalidRetries,
ogWifiClientRxInvalidMisc,
ogWifiClientMissedBeacon,
ogWifiClientCounter,
ogWifiApInterface,
ogWifiApEnabled,
ogWifiApSsid,
ogWifiApIeeeMode,
ogWifiApFrequency,
ogWifiApTxPower,
ogWifiApCounter,
ogWifiApClientAp,
ogWifiApClientMac,
ogWifiApClientInactiveTime,
ogWifiApClientRxBytes,
ogWifiApClientRxPackets,
ogWifiApClientTxBytes,
ogWifiApClientTxPackets,
ogWifiApClientRssi,
ogWifiApClientTxBitRate,
ogCheckName,
ogCheckRepeatTimeout,
ogCheckResetTimeout,
ogCheckType,
ogCheckTriggerActions,
ogCheckResolveActions,
ogCheckDeviceCheck,
ogCheckDeviceName,
ogCheckDeviceRef
}
STATUS current
DESCRIPTION
"A collection of objects to retrieve Opengear statistics."
::= { ogStatus2Groups 1 }
ogBasicAlarmGroup OBJECT-GROUP
OBJECTS {
ogAlarmEventId,
ogAlarmName,
ogAlarmCheck,
ogAlarmInstance,
ogAlarmTime,
ogAlarmType,
ogAlarmSummary,
ogAlarmDevice,
ogAlarmUser,
ogAlarmTriggerValue,
ogAlarmCurrentValue,
ogAlarmPreviousValue,
ogAlarmState,
ogCurrentAlarmEventId,
ogCurrentAlarmName,
ogCurrentAlarmCheck,
ogCurrentAlarmInstance,
ogCurrentAlarmTime,
ogCurrentAlarmType,
ogCurrentAlarmSummary,
ogCurrentAlarmDevice,
ogCurrentAlarmUser,
ogCurrentAlarmTriggerValue,
ogCurrentAlarmCurrentValue,
ogCurrentAlarmPreviousValue,
ogCurrentAlarmState
}
STATUS current
DESCRIPTION
"A collection of objects to report Opengear alarms."
::= { ogStatus2Groups 2 }
ogBasicNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
ogSerialSignalNotification,
ogSerialPatternNotification,
ogSerialUserNotification,
ogHostPingNotification,
ogHostServiceNotification,
ogHostUserNotification,
ogWebUserNotification,
ogEmdDioNotification,
ogEmdTemperatureNotification,
ogEmdHumidityNotification,
ogPowerSupplyInputNotification,
ogPowerSupplyOutputNotification,
ogPowerSupplyTempNotification,
ogUpsNotification,
ogUpsInputNotification,
ogUpsBatteryNotification,
ogUpsOutputNotification,
ogRpcInputNotification,
ogRpcOutputNotification,
ogRpcOutletNotification,
ogNetInterfaceNotification,
ogCellDataNotification,
ogCellMessageNotification,
ogCellSignalNotification,
ogCellApnNotification,
ogCellTowerNotification,
ogCellNetworkNotification,
ogWifiClientConnectNotification,
ogWifiClientSignalNotification,
ogWifiApAssociationNotification,
ogWifiApAuthNotification,
ogDialPoolHealthNotification,
ogCustomNotification,
ogCliUserSessionNotification
}
STATUS current
DESCRIPTION
"A collection of notifications for the status system."
::= { ogStatus2Groups 3 }
END