mibs/MIBS/sagemcom/LOG-MIB

928 lines
29 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--*******************************************************************
--* SAGEM, IONOS *
--*******************************************************************
--*******************************************************************
-- Filename: log
--
-- File type: .mib
--
-- Description: SNMP source Mib file.
--
-- describes alarmes and event log records and
-- associated traps
--
--
-- Version: 19 11 2002
--
-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
--
-- Contact: D. Mobuchon, F. Bonnevialle
--
-- History:
-- Version: Date: 25 10 1999
-- Version: MIB-P0-301199 Date: 30 11 1999
-- Version: MIB-P0-05092000 Date: 05 09 2000
-- passage de performance en perf pour
-- diminuer la longueur des traps de l'ADR155
-- Version: Date: 14 06 2001
-- ajout table de defaut courant pour gestionnaire
-- Version: Date: 22 08 2001
-- LogCurrent comments modification
--
-- Version: MIB-P0-301199 Date: 30 11 1999
--
-- Name: F.Bonnevialle
-- Date: 15 11 2002
-- Desc: Modification for SilverCreek Compiler
--*******************************************************************
--*******************************************************************
--* Copyright (c) 2002, SAGEM , All rights reserved. *
--*******************************************************************
--*******************************************************************
-- MIB: LOG-MIB
--*******************************************************************
LOG-MIB DEFINITIONS ::= BEGIN
--*******************************************************************
-- IMPORTS
--*******************************************************************
IMPORTS
sagemDr FROM SAGEM-DR-MIB
SagemBoolean,IntDateTime,Severity FROM EQUIPMENT-MIB
DisplayString FROM SNMPv2-TC
MODULE-IDENTITY,OBJECT-TYPE,
NOTIFICATION-TYPE FROM SNMPv2-SMI;
-- TRAP-TYPE FROM RFC-1215;
--*******************************************************************
-- OBJECTS
--*******************************************************************
log MODULE-IDENTITY
LAST-UPDATED "0211150000Z"
ORGANIZATION "SAGEM/DR Tolbiac Centre"
CONTACT-INFO
" "
DESCRIPTION
"
Modification:
Date: 15 11 2002
Description:
sagemDr replace sagem-dr
NOTIFICATION-TYPE replace TRAP-TYPE
Modification:
Date: 20 12 1999
Description: Modification of comments
Modification of trap re-notification
quality-threshold-overflow replaced by
performance.
New Object:
Date: 30 11 1999
Name: lostTrapBool,lostTrapBegin,lostTrapEnd,lostTrap
Description: System of re-notification of lost traps,
Name: LodEvent
Description: Add of qualityThresholdOverflow (20),
otherThresholdOverflow (21), maintenance (30)
Name: probableCause
Description: SIZE (0..20) replaced by SIZE (0..50)
Creation:
This MIB module describes alarmes and event log records.
It also describes associated trap
"
::= { sagemDr 105 }
-- Warning:
-- The events (13) and (31) are non cleared
--
LogEvent ::= INTEGER { clear (0), nonAlarmed (1),
minor (2), major (3), critical (4), warning (5),
raise (10), -- some events requires raise/clear
event (13), -- for cold/hot start, re-notification, version switching
switch (14),
perf (20),
otherThresholdOverflow (21),
maintenance (30)
-- used for login/logout, start/end write session,
-- download/upload, operator action
-- ,security (31)
}
logClear OBJECT-TYPE
SYNTAX INTEGER { setToClear(0) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When a set command is issued on this variable the entire
log event is cleared.
This command is optional
"
::= { log 1 }
logCapacity OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of event in the log database"
::= { log 2 }
logLastEvent OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the last event number that have been logged.
This is usefull for trap lost detection."
::= { log 3 }
logNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of current log in equipment."
::= { log 4 }
logTable OBJECT-TYPE
SYNTAX SEQUENCE OF LogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of log trap that come from the equipment."
::= { log 5 }
logEntry OBJECT-TYPE
SYNTAX LogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular log of the equipment."
INDEX { logIndex }
::= { logTable 1 }
LogEntry ::=
SEQUENCE {
logIndex INTEGER,
logDate IntDateTime,
logObject OBJECT IDENTIFIER,
logName DisplayString,
logEvent LogEvent,
logPC DisplayString,
logAI DisplayString,
logEquipStatusV2 Severity
}
logIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular log entry.
The index value cannot exced logCapacity and then returns
to zero when the number of events exceds the capacity of
equipement log table.
Its value is :
logIndex = <total number of event>%logCapacity.
It is mandatory for the equipment to respond to get-next in
anti-chronological order (youngest first) no matter to the
index value.
Get-next(LogEntry.logEntry) is logEntry.logIndex[logLastEvent]"
::= { logEntry 1 }
logDate OBJECT-TYPE
SYNTAX IntDateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the event had happened."
::= { logEntry 2 }
logObject OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to the function/interface who produced the event"
::= { logEntry 3 }
logName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A text string which identifies the particular entry among the
log entries. "
::= { logEntry 4 }
logEvent OBJECT-TYPE
SYNTAX LogEvent
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"indicates the type of event which had occured"
::= { logEntry 5 }
-- The folowing probable cause are the mnemonics of failures
-- For all failures, the event indicates both the status and
-- the associed severity.
-- The event is non-alarmed, minor, major, critical or warning
-- if the failure has raised, and is clear when it has
-- desapeared.The LogObject is the oid of the
-- function/interface which notified the failure
-- los, tf, ais, lof, eber, sd, rdi, lop, pam, scm, otm,
-- slm, uneq, lom, tim, etc ...
--
-- For user-input associated failure, the probable cause
-- is the string name associated with the input.
-- For performance threshold exced the event is
-- "performance" and probable cause is "threshold exceded".
-- For Msp switch the event is "switch", probable cause is
-- "msp on working" or "msp on protection". oid indicates
-- msp function.
-- Sets source fail failure mnemonique is "source fail" and
-- oid is the value of setsInTable[source who failed]
-- On T0 switch the event "switch" is issued with probable
-- cause "t0 switch" and oid setsInTable[new-src]
-- On T4 failure the event "raise" or clear" is issued with
-- probable cause "t4 failure"
-- Note on standarts trap :
-- warmStart rfc1215
-- coldStart rfc1215
-- linkUp
-- linkDown
-- The equipment sends these standard traps througt
-- rfc1215 mib.
-- Then it is no use to send them through this mib but on
-- other hand it may be usefull to store them in the log as
-- an event :
-- event "event", probable cause "warm start" or
-- "cold start", oid={0,0}
-- event "event", probable cause
-- "link up" or "link down",oid=ifEntry.Index
logPC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Probable cause. A short string which identifies the event type.
For a failure it is its mnemonique."
::= { logEntry 6 }
logAI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A short string which gives additional information on
the event"
::= { logEntry 7 }
logEquipStatusV2 OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
logEquipStatusV2 is the value of equipStatusV2
stored in logTable each time a trap is sent"
::= { logEntry 8 }
--*******************************************************************
-- Description:
-- "logTrapEnable"
logTrapEnable OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to false the equipment stops to send logTraps.
It has no effect on event log recording.
It also has no effects on quality traps and on status trap
used for the manager IONOS-ANM-V1.
The default value is true."
::= { log 6 }
--*******************************************************************
-- Modification:
-- Description: System used for notify again lost's
-- traps or current state.
-- Warning: the equipment sends these traps only
-- to the requester.
--
-- 1:Detection of lost traps
-- To detect lost traps:
-- we have to use two values:
-- -one in the equipment: logLastEvent
-- -one in the manager: the number of the last event
-- received by the manager
-- we have to poll regulary logLastEvent and make a
-- comparition with the value stored and maintained in the
-- manager. If the values are different the number of trap
-- lost equal to the difference between the two values.
--
-- 2:Resend lost traps
-- The manager can use GET request on logTable to acces the values.
-- The index of the table is logIndex or logTimeIndex
-- (logTImeIndex is not implemented in P0)
--
-- 3: Resend current state (start...)
-- The manager can set the boolean values of
-- resendTrapBool to get the current state.
-- Sequence to resent traps (current state):
-- For all re-sent traps:
-- Two special traps (logTap for P0) are sent before
-- and after the group of re-sent traps.
-- The logEvent field is: "maintainance" (= 30) for
-- the begining and "clear" for the end.
-- The probableCause field is: "lost trap"
-- The equipment send the following sequence for P0:
-- -1 logTrap with:
-- logEvent="maintainance"
-- probableCause="resent current trap"
-- -a set of logTrap that are current trap
-- In P0 ,you can not make a difference beetwen resent
-- trap and new alarms sent inside the sequence
-- (that are current trap too).
-- -1 logTrap with:
-- logEvent="clear"
-- probableCause="resent current trap"
--********************************************************************
lostTrap OBJECT IDENTIFIER ::= { log 7 }
resendTrapBool OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager set this variable to receive all the current traps of the
equipment.
The equipment must use resentLogTrap and resentNetworkAlarmeTrap
to do it(not in P0)."
::= { lostTrap 1 }
--*********************************************************************
-- Warning: logTime* are NOT used in P0 !
--*********************************************************************
-- logTimeTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF LogTimeEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The logDateTable contains data in the same format as the
-- logTable, and must contain the same set of data, but is
-- indexed using logTimeDate rather than logIndex.
--
-- If the logTable is managed by the equipment, the
-- logTimeTable is optional. Otherwise, the logTimeTable
-- is mandatory.
-- "
-- ::= { log 20 }
--
-- logTimeEntry OBJECT-TYPE
-- SYNTAX LogTimeEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "Refer to the same object in the logTable."
-- INDEX { logTimeDate }
-- ::= { logTimeTable 1 }
--
-- LogTimeEntry ::=
-- SEQUENCE {
-- logTimeIndex INTEGER,
-- logTimeDate IntDateTime,
-- logTimeObject OBJECT IDENTIFIER,
-- logTimeName DisplayString,
-- logTimeEvent LogEvent,
-- logTimeProbableCause DisplayString,
-- logTimeAI DisplayString,
-- logTimeEquipmentStatus Severity
-- }
--
-- logTimeIndex OBJECT-TYPE
-- SYNTAX INTEGER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Refer to the same object in the logTable."
-- ::= { logTimeEntry 1 }
--
-- logTimeDate OBJECT-TYPE
-- SYNTAX IntDateTime
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Refer to the same object in the logTable."
-- ::= { logTimeEntry 2 }
--
-- logTimeObject OBJECT-TYPE
-- SYNTAX OBJECT IDENTIFIER
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Refer to the same object in the logTable."
-- ::= { logTimeEntry 3 }
--
-- logTimeName OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..40))
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Refer to the same object in the logTable."
-- ::= { logTimeEntry 4 }
--
-- logTimeEvent OBJECT-TYPE
-- SYNTAX LogEvent
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Refer to the same object in the logTable."
-- ::= { logTimeEntry 5 }
--
-- logTimeProbableCause OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..50))
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Refer to the same object in the logTable."
-- ::= { logTimeEntry 6 }
--
-- logTimeAI OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..64))
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Refer to the same object in the logTable."
-- ::= { logTimeEntry 7 }
--
-- logTimeEquipmentStatus OBJECT-TYPE
-- SYNTAX Severity
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Refer to the same object in the logTable."
-- ::= { logTimeEntry 8 }
--
--*******************************************************************
-- logTrap TRAP-TYPE
-- ENTERPRISE log
-- VARIABLES { logIndex, logDate, logObject,
-- logName, logEvent, logPC,
-- logAI,logEquipStatusV2}
-- DESCRIPTION
-- "A trap of this type indicates a failure or an event in the
-- corresponding interface/function. It also gives the date and
-- time when the trap was sent, and the equipment status.
--
-- The logTrap is recommended for the equipment layer management.
-- The networkAlarmeTrap is recommended for the network layer management.
-- "
-- ::= 1
-- thresholdTrap TRAP-TYPE
-- ENTERPRISE log
-- VARIABLES { logIndex, logDate, logObject,
-- logName, logEvent, logPC,
-- logAI,logEquipStatusV2}
-- DESCRIPTION
-- "A trap of this type indicates that a threshold has been
-- crossed in the corresponding interface/function.
-- It also gives the date and time when the trap was sent,
-- and the equipment status"
-- ::= 2
logTraps OBJECT IDENTIFIER ::= { log 0 }
logTrap NOTIFICATION-TYPE
OBJECTS { logIndex, logDate, logObject,
logName, logEvent, logPC,
logAI,logEquipStatusV2 }
STATUS current
DESCRIPTION "A trap of this type indicates that a threshold has been
crossed in the corresponding interface/function.
It also gives the date and time when the trap was sent,
and the equipment status"
REFERENCE ""
::= { logTraps 1 }
thresholdTrap NOTIFICATION-TYPE
OBJECTS { logIndex, logDate, logObject,
logName, logEvent, logPC,
logAI,logEquipStatusV2 }
STATUS current
DESCRIPTION "A trap of this type indicates that a threshold has been
crossed in the corresponding interface/function.
It also gives the date and time when the trap was sent,
and the equipment status"
REFERENCE ""
::= { logTraps 2 }
-- Warning:
-- The next traps are NOT used with P0 version
--
-- securityTrap TRAP-TYPE
-- ENTERPRISE log
-- VARIABLES { logIndex, logDate, logObject,
-- logName, logEvent, logPC,
-- logAI,logEquipStatusV2}
-- DESCRIPTION
-- "A trap of this type indicates that a security event has been
-- appeared.
-- "
-- ::= 3
--
-- networkAlarmeTrap TRAP-TYPE
-- ENTERPRISE log
-- VARIABLES { logIndex, logDate, logObject,
-- logName, logEvent, logPC,
-- logAI,logEquipStatusV2}
-- DESCRIPTION
-- "A trap of this type indicates that a network event has been
-- appeared. Special network event used by the IONOS-ANM manager
-- to have an easily network layer management.
-- "
-- ::= 4
--
-- maintainanceTrap TRAP-TYPE
-- ENTERPRISE log
-- VARIABLES { logIndex, logDate, logObject,
-- logName, logEvent, logPC,
-- logAI,logEquipStatusV2}
-- DESCRIPTION
-- "A trap of this type indicates that a maintainance event has been
-- appeared.
-- "
-- ::= 5
--
-- resentLogTrap TRAP-TYPE
-- ENTERPRISE log
-- VARIABLES { logIndex, logDate, logObject,
-- logName, logEvent, logPC,
-- logAI,logEquipStatusV2}
-- DESCRIPTION
-- "This trap is used to re-send logTrap."
-- ::= 6
--
-- resentNetworkAlarmeTrap TRAP-TYPE
-- ENTERPRISE log
-- VARIABLES { logIndex, logDate, logObject,
-- logName, logEvent, logPC,
-- logAI,logEquipStatusV2}
-- DESCRIPTION
-- "This trap is used to re-send networkAlarmeTrap."
-- ::= 7
--
--***************************************************************
-- Meaning and values of variables of the different kind of trap
--***************************************************************
-- Only logTrap and thresholdTrap are used for P0;
-- So the other traps described are logTrap:
-- networkAlarmTrap
-- maintainanceTrap
-- securityTrap
--
-- That means in P0 Version, networkAlarmTrap,maintainanceTrap,
-- and securityTrap are not implemented and are replaced by
-- a logTrap with the same format than respectively networkAlarmTrap,
-- maintainanceTrap and securityTrap
--
--
-- ===============================
-- 1:logTrap
-- ===============================
--
-- 1.1:Equipment Alarm traps
-- *********************
--
-- logObject : equipment OID or daughter card OID or ...
-- logName : "Alarm name", ...
-- logEvent : clear, non-alarmed, minor, major, critical, warning ...
-- logProbableCause : "ProbableCause"
-- logAI: "", "AI"
--
--
--
-- ===============================
-- 2:networkAlarmTrap
-- ===============================
--
-- 2.1:Network Alarm traps
-- *******************
--
-- logObject : interface OID or access OID ...
-- logName : not yet defined !!!!
-- logName : "Slot=0, Card=ADSL, Prot=ATM, VP/VC=12/8", ...
-- logEvent : clear, non-alarmed, minor, major, critical, warning ...
-- logProbableCause : "ProbableCause"
-- logAI: "", "AI"
--
--
--
-- ===============================
-- 3:maintainanceTrap
-- ===============================
--
-- 3.1:Download/Upload traps
-- *********************
--
-- logObject : equipment OID or daughter card OID
-- logName : "", "Card name", ...
-- logEvent : maintainance or clear
-- logProbableCause : "download" or "upload"
-- logAI: transferedItemType value, transferedItemVersion value
--
--
-- 3.2:Switching traps
-- ***************
--
-- logObject : equipment OID or daughter card OID
-- logName : "", "Card name", ...
-- logEvent : event
-- logProbableCause : "software switching" or "data configuration switching"
-- logAI: transferedItemType value, transferedItemVersion value
--
--
-- 3.3:Software restart traps
-- **********************
-- (Restart none requested by an operator).
--
-- logObject : equipment OID or daughter card OID
-- logName : "", "Card name"
-- logEvent : event
-- logProbableCause : "cold start" or "hot start"
-- logAI: "" or "additionnal info"
--
--
-- 3.4:Maintainance action traps with end
-- **********************************
--
-- logObject : port OID or card OID
-- logName : "name of the localisation"
-- logEvent : maintainance or clear
-- logProbableCause : "loop back" or ...
-- logAI: "loop number = xx" or ...
--
--
-- 3.5:Maintainance action traps without end
-- *************************************
--
-- logObject : port OID or card OID
-- logName : "name of the localisation"
-- logEvent : event
-- logProbableCause : "clock switching" or ...
-- logAI: "" or ...
--
--
-- 3.6:Write-session traps
-- *******************
-- A "write-session" trap must be sent when a write session starts
-- or ends. (Refer to the Sagem-dr-session Mib for the different
-- field values).
--
-- logObject :
-- logName : "writeSession"
-- logEvent : maintainance or clear (start or end)
-- logProbableCause : "writeSession"
-- logAI: sessionIp,sessionType
--
-- ex: logAI= "135.10.34.24,http,sess2,iONOSANMsupervisor"
--
--
-- 3.7:Re-notification traps
-- *********************
-- Two special traps (trapLog) are sent before and after
-- the group of re-sent traps.
-- The logEvent field is: "maintainance" for the begining and
-- "clear" for the end.
--
-- logObject : equipment OID
-- logName : ""
-- logEvent : maintainance or clear
-- logProbableCause : "current log"
-- logAI: "Requester IP@ = x.x.x.x"
--
-- ===============================
-- 4:thresholdTrap
-- ===============================
--
-- 4.1:performance (Quality-threshold-overflow) traps
-- ********************************
--
-- logObject : cptObject OID
-- logName : "port name"
-- logEvent : quality-threshold-overflow or clear
-- logProbableCause : "quality-threshold-overflow cptNearFar value, cptDuration value"
-- logAI: "max Threshold = xxxx, min Threshold = xxxx"
--
-- 4.2:Other-threshold-overflow traps
-- ******************************
--
-- logObject : variable OID
-- logName : "" or variable name
-- logEvent : other-threshold-overflow or clear
-- logProbableCause : "other threshold overflow"
-- logAI: "max Threshold = xxxx, min Threshold = xxxx"
--
-- ===============================
-- 5:securityTrap
-- ===============================
--
-- 5.1:Security traps
-- **************
--
-- logObject : equipment OID, ...
-- logName : ""
-- logEvent : security
-- logProbableCause : "intrusion attempt"
-- logAI: "Caller IP@ = x.x.x.x, community = xxxxxxx"
--
--***************************************************************
--***************************************************************
-- Log current Alarm
--***************************************************************
-- currentLog Table function the same way as log Table
-- It contains only current alarms
logCurrentClear OBJECT-TYPE
SYNTAX INTEGER { setToClear(0) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When a set command is issued on this variable the entire
log event is cleared.
This command is optional
"
::= { log 101 }
logCurrentCapacity OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of event in the log database
This variable is optional"
::= { log 102 }
logCurrentLastEvent OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the last current alarm number that have been logged.
This variable is optional"
::= { log 103 }
logCurrentNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of current log in equipment."
::= { log 104 }
logCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF LogCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of log trap that come from the equipment."
::= { log 105 }
logCurrentEntry OBJECT-TYPE
SYNTAX LogCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular log of the equipment."
INDEX { logCurrentIndex }
::= { logCurrentTable 1 }
LogCurrentEntry ::=
SEQUENCE {
logCurrentIndex INTEGER,
logCurrentDate IntDateTime,
logCurrentObject OBJECT IDENTIFIER,
logCurrentName DisplayString,
logCurrentEvent LogEvent,
logCurrentPC DisplayString,
logCurrentAI DisplayString,
logCurrentStatusV2 Severity
}
logCurrentIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular logCurrent entry.
The index value is comprised between 1 and logCurrentNumber.
There is no relation between the index Value and the date of the alarm. "
::= { logCurrentEntry 1 }
logCurrentDate OBJECT-TYPE
SYNTAX IntDateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the event had happened."
::= { logCurrentEntry 2 }
logCurrentObject OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to the function/interface who produced the event"
::= { logCurrentEntry 3 }
logCurrentName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A text string which identifies the particular entry among the
log entries. "
::= { logCurrentEntry 4 }
logCurrentEvent OBJECT-TYPE
SYNTAX LogEvent
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"indicates the type of event which had occured"
::= { logCurrentEntry 5 }
logCurrentPC OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Probable cause. A short string which identifies the event type.
For a failure it is its mnemonique."
::= { logCurrentEntry 6 }
logCurrentAI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A short string which gives additional information on
the event"
::= { logCurrentEntry 7 }
logCurrentStatusV2 OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
logEquipStatusV2 is the value of equipStatusV2
stored in logTable each time a trap is sent"
::= { logCurrentEntry 8 }
END