mibs/MIBS/siae/SIAE-UNIT-MIB

302 lines
9.4 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- ----------------------------------------------------------------------------
--
-- SIAE MICROELETTRONICA s.p.a.
--
-- Via Michelangelo Buonarroti, 21
-- 20093 - Cologno Monzese
-- Milano
-- ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------
SIAE-UNIT-MIB
DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32
FROM SNMPv2-SMI
DisplayString, AutonomousType, RowStatus
FROM SNMPv2-TC
siaeMib
FROM SIAE-TREE-MIB
unitTypeUnequipped
FROM SIAE-UNITYPE-MIB
AlarmStatus, AlarmSeverityCode
FROM SIAE-ALARM-MIB;
unit MODULE-IDENTITY
LAST-UPDATED "201402030000Z"
ORGANIZATION "SIAE MICROELETTRONICA spa"
CONTACT-INFO
"SIAE MICROELETTONICA s.p.a.
Via Michelangelo Buonarroti, 21
20093 - Cologno Monzese
Milano - ITALY
Phone : +39-02-27325-1
E-mail: tbd@siaemic.com
"
DESCRIPTION
"Unit inventory MIB. A unit is a replaceable HW card.
"
REVISION "201402030000Z"
DESCRIPTION
"Improved description of unitMibVersion
"
REVISION "201304160000Z"
DESCRIPTION
"Initial version 01.00.00
"
::= { siaeMib 6 }
------------------------------------------------------------------------------
-- object identifier inside the module
------------------------------------------------------------------------------
------------------------------------------------------------------------------
-- unit GROUP
------------------------------------------------------------------------------
--
-- This group is used to manage the units (board and in general replaceable
-- part) present in the equipment.
--
------------------------------------------------------------------------------
------ Beginning --------------------------------------------------------------
------- Begin of unitTable
--
unitMibVersion OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Numerical version of this module.
The string version of this MIB have the following format:
XX.YY.ZZ
so, for example, the value 1 should be interpreted as 00.00.01
and the value 10001 should be interpreted as 01.00.01."
DEFVAL {1}
::= {unit 1}
unitTable OBJECT-TYPE
SYNTAX SEQUENCE OF UnitRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with Unit records."
::= {unit 2}
unitRecord OBJECT-TYPE
SYNTAX UnitRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unit record."
INDEX {unitId}
::= {unitTable 1}
UnitRecord ::=
SEQUENCE {
unitId Integer32,
unitExpectedType AutonomousType,
unitActualType AutonomousType,
unitLabel DisplayString,
unitFailAlarm AlarmStatus,
unitMissingAlarm AlarmStatus,
unitNotRespondingAlarm AlarmStatus,
unitHwMismatchAlarm AlarmStatus,
unitSwMismatchAlarm AlarmStatus,
unitHwEdition DisplayString,
unitPartNumber DisplayString,
unitParentPartNumber DisplayString,
unitParentSerialNumber DisplayString,
unitRowStatus RowStatus
}
unitId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used as Index of the Unit Table."
::= {unitRecord 1}
unitExpectedType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Defines the expected unit type."
DEFVAL { unitTypeUnequipped }
::= {unitRecord 2}
unitActualType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the real unit type actually present in the equipment"
DEFVAL { unitTypeUnequipped }
::= {unitRecord 3}
unitLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string used to assign a name to the unit."
::= {unitRecord 4}
unitFailAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit Fail alarm status status with associated severity."
DEFVAL { activeReportableMajor }
::= {unitRecord 5}
unitMissingAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit Missing alarm status with associated severity."
DEFVAL { activeReportableMajor }
::= {unitRecord 6}
unitNotRespondingAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit Not Responding alarm status with associated severity."
DEFVAL { activeReportableMajor }
::= {unitRecord 7}
unitHwMismatchAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit type Mismatch alarm status with associated severity."
DEFVAL { activeReportableMajor }
::= {unitRecord 8}
unitSwMismatchAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit with Sw Release Mismatch alarm status with associated severity."
DEFVAL { activeReportableMajor }
::= {unitRecord 9}
unitHwEdition OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ASCII string used to identify Hw edition of the unit."
::= {unitRecord 10}
unitPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ASCII string to identify the Part Number of the unit."
::= {unitRecord 11}
unitParentPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ASCII string to identify the parent Part Number of the unit."
::= {unitRecord 12}
unitParentSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ASCII string to identify parent Serial Number of the unit."
::= {unitRecord 13}
unitRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this row of unitTable.
"
::= {unitRecord 14}
--
------- End of unitTable
--
------- The following objects define the profile of the unit alarms:
--
-- OBJECT-IDENTIFIER {unit 3} is used in sm_unitype.mib
unitFailAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the unitFailAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {unit 4}
unitMissingAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the unitMissingAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {unit 5}
unitNotRespondingAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the unitNotRespondingAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {unit 6}
unitHwMismatchAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the unitHwMismatchAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {unit 7}
unitSwMismatchAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the unitSwMismatchAlarm
and enables/disables the trap generation on status change event."
DEFVAL {majorTrapEnable}
::= {unit 8}
------ End group -------------------------------------------------------------
END