mibs/MIBS/smartoptics/MSERIES-ALARM-MIB

736 lines
24 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- SmartOptics Enterprise Specific Alarm MIB.
--
-- Copyright (c) 2011, SmartOptics
-- All rights reserved
--
MSERIES-ALARM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Counter32, Integer32
FROM SNMPv2-SMI
DisplayString, DateAndTime
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
AlarmPerceivedSeverity, AlarmNotificationType, AlarmProbableCause, UnitType, PortType
FROM MSERIES-TC
mseries
FROM MSERIES-MIB;
smartAlarm MODULE-IDENTITY
LAST-UPDATED "201402121415Z"
ORGANIZATION "SmartOptics"
CONTACT-INFO "http://www.smartoptics.com"
DESCRIPTION
"This is the enterprise specific Alarm MIB for SmartOptics M-Series"
REVISION "201402121415Z"
DESCRIPTION
"Added alarmLogList and smartAlarmMIBConformance."
REVISION "201310151341Z"
DESCRIPTION
"Added alarmHostName, alarmPortName and alarmPortType to AlarmEntry.
Added alarmHostName, alarmPortName and alarmPortType to
alarmNotificationCleared, alarmNotificationWarning,
alarmNotificationMinor, alarmNotificationMajor,
and alarmNotificationCritical.
Also alarmPort reports different numbers against before
(changed from SmartOS v2.1). 1-10 means Line ports
and 11 and above means Client port.
Descriptions are also updated."
REVISION "201112050000Z"
DESCRIPTION
"Initial revision.
Added notifications."
::= { mseries 1 }
alarmGeneral OBJECT IDENTIFIER
::= { smartAlarm 1}
alarmActiveList OBJECT IDENTIFIER
::= { smartAlarm 2}
alarmLogList OBJECT IDENTIFIER
::= { smartAlarm 3}
alarmNotifications OBJECT IDENTIFIER
::= { smartAlarm 4}
smartAlarmMIBConformance OBJECT IDENTIFIER
::= { smartAlarm 5}
smartAlarmGroups OBJECT IDENTIFIER
::= { smartAlarmMIBConformance 1}
smartAlarmCompliances OBJECT IDENTIFIER
::= { smartAlarmMIBConformance 2}
--
-- General alarm group
--
smartAlarmGeneralLastSeqNumber OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sequence number of the last sent notification."
::= { alarmGeneral 1 }
smartAlarmGeneralHighestSeverity OBJECT-TYPE
SYNTAX AlarmPerceivedSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current highest severity of the active alarms."
::= { alarmGeneral 2 }
smartAlarmGeneralNumberActiveList OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of active alarms in the alarmActiveList."
::= { alarmGeneral 3 }
smartAlarmGeneralNumberLogList OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of alarms in the alarmLogList."
::= { alarmGeneral 4 }
--
-- Alarm active list group
--
alarmActiveTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The active alarm list."
::= { alarmActiveList 1 }
alarmEntry OBJECT-TYPE
SYNTAX AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the active alarm list."
INDEX { alarmIndex }
::= { alarmActiveTable 1 }
AlarmEntry ::=
SEQUENCE {
alarmIndex Unsigned32,
alarmUnit UnitType,
alarmPort Integer32,
alarmText DisplayString,
alarmSeverity AlarmPerceivedSeverity,
alarmActivationTime DateAndTime,
alarmCeaseTime DateAndTime,
alarmSeqNumber Counter32,
alarmHostName DisplayString,
alarmPortName DisplayString,
alarmPortType PortType,
alarmType AlarmNotificationType,
alarmCause AlarmProbableCause,
alarmPortAlias DisplayString
}
alarmIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An unique index assigned to each alarm."
::= { alarmEntry 1 }
alarmUnit OBJECT-TYPE
SYNTAX UnitType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarming unit associated with this alarm.
undefined(0), nmb(1), psu1(2), psu2(3), fan(4), system(5),
slaveNmb(6), slavePsu1(7), slavePsu2(8), slaveFan(9)."
::= { alarmEntry 2 }
alarmPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarming port associated with this alarm.
1-10 is Line Ports. 11 and higher is Client ports. For non port alarms this value is 0."
::= { alarmEntry 3 }
alarmText OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The additional text for the alarm."
::= { alarmEntry 4 }
alarmSeverity OBJECT-TYPE
SYNTAX AlarmPerceivedSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm as defined in
ITU-T X.733."
::= { alarmEntry 5 }
alarmActivationTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time when the alarm was created."
::= { alarmEntry 6 }
alarmCeaseTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time when the alarm was ceased."
::= { alarmEntry 7 }
alarmSeqNumber OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last sequence number used when issuing
a notification for this alarm."
::= { alarmEntry 8 }
alarmHostName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hostname."
::= { alarmEntry 9 }
alarmPortName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Port Name."
::= { alarmEntry 10 }
alarmPortType OBJECT-TYPE
SYNTAX PortType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Port Type. undefined(0), rx(1), tx(2), biDi(3)."
::= { alarmEntry 11 }
alarmType OBJECT-TYPE
SYNTAX AlarmNotificationType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of alarm as defined in ITU-T X.733
undefined (0),
other (1),
communicationsAlarm (2),
qualityOfServiceAlarm (3),
processingErrorAlarm (4),
equipmentAlarm (5),
environmental (6),
integrityViolation (7),
operationalViolation (8),
physicalViolation(9),
securityServiceOrMechanismViloation (10),
timeDomainViolation (11)"
::= { alarmEntry 12 }
alarmCause OBJECT-TYPE
SYNTAX AlarmProbableCause
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm probable cause as defined in ITU-T X.733.
undefined (0)
adapterError (1) -- Equipment
applicationSubsystemFailure (2) -- Processing
bandwidthReduced (3) -- Quality of service
callEstablishmentError (4) -- Communications
communicationsProtocolError (5) -- Communications
communicationsSubsystemFailure (6) -- Communications
configurationOrCustomizationError (7) -- Processing
congestion (8) -- Quality of service
corruptData (9) -- Processing
cpuCyclesLimitExceeded (10) -- Processing
dTEdCEInterfaceError (11) -- Communications
datasetOrModemError (12) -- Equipment
degradedSignal (13) -- Communications
enclosureDoorOpen (14) -- Environmental
equipmentMalfunction (15) -- Equipment
excessiveVibration (16) -- Environmental
fileError (17) -- Processing
fireDetected (18) -- Environmental
floodDetected (19) -- Environmental
framingError (20) -- Communications
heatingOrVentilationOrCoolingSystemProblem (21) -- Environmental
humidityUnacceptable (22) -- Environmental
inputDeviceError (23) -- Equipment
inputOutputDeviceError (24) -- Equipment
lANError (25) -- Communications
leakDetected (26) -- Environmental
localNodeTransmissionError (27) -- Communications
lossOfFrame (28) -- Communications
lossOfSignal (29) -- Communications
materialSupplyExhausted (30) -- Environmental
multiplexerProblem (31) -- Equipment
outOfMemory (32) -- Processing
outputDeviceError (33) -- Equipment
performanceDegraded (34) -- Quality of service
powerProblem (35) -- Equipment
pressureUnacceptable (36) -- Environmental
processorProblem (37) -- Equipment
pumpFailure (38) -- Environmental
queueSizeExceeded (39) -- Quality of service
receiveFailure (40) -- Equipment
receiverFailure (41) -- Equipment
remoteNodeTransmissionError (42) -- Communications
resourceAtOrNearingCapacity (43) -- Quality of service
responseTimeExcessive (44) -- Quality of service
retransmissionRateExcessive (45) -- Quality of service
softwareProgramError (46) -- Processing
softwareError (47) -- Processing
softwareProgramAbnormallyTerminated (48) -- Processing
storageCapacityProblem (49) -- Processing
temperatureUnacceptable (50) -- Environmental
thresholdCrossed (51) -- Quality of service
timingProblem (52) -- Equipment
toxicLeakDetected (53) -- Environmental
transmitFailure (54) -- Equipment
transmitterFailure (55) -- Equipment
underlyingResourceUnavailable (56) -- Processing
versionMismatch (57) -- Processing"
::= { alarmEntry 13 }
alarmPortAlias OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Port Alias."
::= { alarmEntry 14 }
--
-- Alarm active list group
--
alarmLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The active alarm list."
::= { alarmLogList 1 }
alarmLogEntry OBJECT-TYPE
SYNTAX AlarmLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the alarm log table."
INDEX { alarmLogIndex }
::= { alarmLogTable 1 }
AlarmLogEntry ::=
SEQUENCE {
alarmLogIndex Unsigned32,
alarmLogUnit UnitType,
alarmLogPort Integer32,
alarmLogText DisplayString,
alarmLogSeverity AlarmPerceivedSeverity,
alarmLogActivationTime DateAndTime,
alarmLogCeaseTime DateAndTime,
alarmLogSeqNumber Counter32,
alarmLogHostName DisplayString,
alarmLogPortName DisplayString,
alarmLogPortType PortType,
alarmLogType AlarmNotificationType,
alarmLogCause AlarmProbableCause
}
alarmLogIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An unique index assigned to each alarm."
::= { alarmLogEntry 1 }
alarmLogUnit OBJECT-TYPE
SYNTAX UnitType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarming unit associated with this alarm.
undefined(0), nmb(1), psu1(2), psu2(3), fan(4), system(5),
slaveNmb(6), slavePsu1(7), slavePsu2(8), slaveFan(9)."
::= { alarmLogEntry 2 }
alarmLogPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarming port associated with this alarm.
1-10 is Line Ports. 11 and higher is Client ports. For non port alarms this value is 0."
::= { alarmLogEntry 3 }
alarmLogText OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The additional text for the alarm."
::= { alarmLogEntry 4 }
alarmLogSeverity OBJECT-TYPE
SYNTAX AlarmPerceivedSeverity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm as defined in
ITU-T X.733."
::= { alarmLogEntry 5 }
alarmLogActivationTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time when the alarm was created."
::= { alarmLogEntry 6 }
alarmLogCeaseTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time when the alarm was ceased."
::= { alarmLogEntry 7 }
alarmLogSeqNumber OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last sequence number used when issuing
a notification for this alarm."
::= { alarmLogEntry 8 }
alarmLogHostName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hostname."
::= { alarmLogEntry 9 }
alarmLogPortName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Port Name."
::= { alarmLogEntry 10 }
alarmLogPortType OBJECT-TYPE
SYNTAX PortType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Port Direction. rx(1), tx(2), biDi(3)."
::= { alarmLogEntry 11 }
alarmLogType OBJECT-TYPE
SYNTAX AlarmNotificationType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of alarm as defined in ITU-T X.733
undefined (0),
other (1),
communicationsAlarm (2),
qualityOfServiceAlarm (3),
processingErrorAlarm (4),
equipmentAlarm (5),
environmental (6),
integrityViolation (7),
operationalViolation (8),
physicalViolation(9),
securityServiceOrMechanismViloation (10),
timeDomainViolation (11)"
::= { alarmLogEntry 12 }
alarmLogCause OBJECT-TYPE
SYNTAX AlarmProbableCause
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm probable cause as defined in ITU-T X.733.
undefined (0)
adapterError (1) -- Equipment
applicationSubsystemFailure (2) -- Processing
bandwidthReduced (3) -- Quality of service
callEstablishmentError (4) -- Communications
communicationsProtocolError (5) -- Communications
communicationsSubsystemFailure (6) -- Communications
configurationOrCustomizationError (7) -- Processing
congestion (8) -- Quality of service
corruptData (9) -- Processing
cpuCyclesLimitExceeded (10) -- Processing
dTEdCEInterfaceError (11) -- Communications
datasetOrModemError (12) -- Equipment
degradedSignal (13) -- Communications
enclosureDoorOpen (14) -- Environmental
equipmentMalfunction (15) -- Equipment
excessiveVibration (16) -- Environmental
fileError (17) -- Processing
fireDetected (18) -- Environmental
floodDetected (19) -- Environmental
framingError (20) -- Communications
heatingOrVentilationOrCoolingSystemProblem (21) -- Environmental
humidityUnacceptable (22) -- Environmental
inputDeviceError (23) -- Equipment
inputOutputDeviceError (24) -- Equipment
lANError (25) -- Communications
leakDetected (26) -- Environmental
localNodeTransmissionError (27) -- Communications
lossOfFrame (28) -- Communications
lossOfSignal (29) -- Communications
materialSupplyExhausted (30) -- Environmental
multiplexerProblem (31) -- Equipment
outOfMemory (32) -- Processing
outputDeviceError (33) -- Equipment
performanceDegraded (34) -- Quality of service
powerProblem (35) -- Equipment
pressureUnacceptable (36) -- Environmental
processorProblem (37) -- Equipment
pumpFailure (38) -- Environmental
queueSizeExceeded (39) -- Quality of service
receiveFailure (40) -- Equipment
receiverFailure (41) -- Equipment
remoteNodeTransmissionError (42) -- Communications
resourceAtOrNearingCapacity (43) -- Quality of service
responseTimeExcessive (44) -- Quality of service
retransmissionRateExcessive (45) -- Quality of service
softwareProgramError (46) -- Processing
softwareError (47) -- Processing
softwareProgramAbnormallyTerminated (48) -- Processing
storageCapacityProblem (49) -- Processing
temperatureUnacceptable (50) -- Environmental
thresholdCrossed (51) -- Quality of service
timingProblem (52) -- Equipment
toxicLeakDetected (53) -- Environmental
transmitFailure (54) -- Equipment
transmitterFailure (55) -- Equipment
underlyingResourceUnavailable (56) -- Processing
versionMismatch (57) -- Processing"
::= { alarmLogEntry 13 }
--
-- Notifications
--
alarmNotifyPrefix OBJECT IDENTIFIER ::= { alarmNotifications 0 }
alarmNotificationCleared NOTIFICATION-TYPE
OBJECTS {
alarmIndex,
alarmUnit,
alarmPort,
alarmText,
alarmSeverity,
alarmActivationTime,
alarmCeaseTime,
alarmSeqNumber,
alarmHostName,
alarmPortName,
alarmPortType,
alarmPortAlias }
STATUS current
DESCRIPTION
"Sent when an alarm is cleared."
::= { alarmNotifyPrefix 1 }
alarmNotificationWarning NOTIFICATION-TYPE
OBJECTS {
alarmIndex,
alarmUnit,
alarmPort,
alarmText,
alarmSeverity,
alarmActivationTime,
alarmCeaseTime,
alarmSeqNumber,
alarmHostName,
alarmPortName,
alarmPortType,
alarmPortAlias }
STATUS current
DESCRIPTION
"Sent when an alarm with warning severity is activated."
::= { alarmNotifyPrefix 2 }
alarmNotificationMinor NOTIFICATION-TYPE
OBJECTS {
alarmIndex,
alarmUnit,
alarmPort,
alarmText,
alarmSeverity,
alarmActivationTime,
alarmCeaseTime,
alarmSeqNumber,
alarmHostName,
alarmPortName,
alarmPortType,
alarmPortAlias }
STATUS current
DESCRIPTION
"Sent when an alarm with minor severity is activated."
::= { alarmNotifyPrefix 3 }
alarmNotificationMajor NOTIFICATION-TYPE
OBJECTS {
alarmIndex,
alarmUnit,
alarmPort,
alarmText,
alarmSeverity,
alarmActivationTime,
alarmCeaseTime,
alarmSeqNumber,
alarmHostName,
alarmPortName,
alarmPortType,
alarmPortAlias }
STATUS current
DESCRIPTION
"Sent when an alarm with major severity is activated.."
::= { alarmNotifyPrefix 4 }
alarmNotificationCritical NOTIFICATION-TYPE
OBJECTS {
alarmIndex,
alarmUnit,
alarmPort,
alarmText,
alarmSeverity,
alarmActivationTime,
alarmCeaseTime,
alarmSeqNumber,
alarmHostName,
alarmPortName,
alarmPortType,
alarmPortAlias }
STATUS current
DESCRIPTION
"Sent when an alarm with critical severity is activated."
::= { alarmNotifyPrefix 5 }
-- ----------------------------------------------------
-- Conformance
-- ----------------------------------------------------
-- ----------------------------------------------------
-- Groups
-- ----------------------------------------------------
smartAlarmGeneralGroupV1 OBJECT-GROUP
OBJECTS { smartAlarmGeneralLastSeqNumber,
smartAlarmGeneralHighestSeverity,
smartAlarmGeneralNumberActiveList,
smartAlarmGeneralNumberLogList }
STATUS current
DESCRIPTION
"The general alarm objects V1."
::= { smartAlarmGroups 1 }
smartAlarmNotificationGroupV1 NOTIFICATION-GROUP
NOTIFICATIONS { alarmNotificationCleared,
alarmNotificationCritical,
alarmNotificationMajor,
alarmNotificationMinor,
alarmNotificationWarning }
STATUS current
DESCRIPTION
"The alarm notifications V1."
::= { smartAlarmGroups 2 }
smartAlarmActiveTableGroupV1 OBJECT-GROUP
OBJECTS { alarmIndex,
alarmUnit,
alarmPort,
alarmText,
alarmSeverity,
alarmActivationTime,
alarmCeaseTime,
alarmSeqNumber,
alarmHostName,
alarmPortName,
alarmPortType,
alarmType,
alarmCause }
STATUS current
DESCRIPTION
"The active alarm table objects V1."
::= { smartAlarmGroups 3 }
smartAlarmLogTableGroupV1 OBJECT-GROUP
OBJECTS { alarmLogIndex,
alarmLogUnit,
alarmLogPort,
alarmLogText,
alarmLogSeverity,
alarmLogActivationTime,
alarmLogCeaseTime,
alarmLogSeqNumber,
alarmLogHostName,
alarmLogPortName,
alarmLogPortType,
alarmLogType,
alarmLogCause }
STATUS current
DESCRIPTION
"The alarm log table objects V1."
::= { smartAlarmGroups 4 }
-- ----------------------------------------------------
-- Compliance
-- ----------------------------------------------------
smartAlarmBasicComplV1 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Basic implementation requirements for the alarm MIB V1."
MODULE
MANDATORY-GROUPS {
smartAlarmGeneralGroupV1,
smartAlarmNotificationGroupV1,
smartAlarmActiveTableGroupV1,
smartAlarmLogTableGroupV1 }
::= { smartAlarmCompliances 1 }
END