-- ** Filename: PRVT-CFM-MIB.mib
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications.
-- BATM Advanced Communications retains all title and
-- ownership in the Specification, including any revisions.
-- BATM Advanced Communications grants all interested parties a non-exclusive
-- license to use and distribute an unmodified copy of this
-- Specification in connection with management of BATM Advanced Communications
-- and Telco Systems<6D>products, and without fee, provided that the following
-- conditions are met:
-- 1. Redistributions of this specification must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
-- or promote products derived from this specification without specific prior written
-- permission.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
PRVT-CFM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32 FROM SNMPv2-SMI -- [RFC2578]
DisplayString,
RowStatus,
TruthValue,
MacAddress
FROM SNMPv2-TC -- [RFC2579]
Dot1afCfmIndexIntegerNextFree,
Dot1agCfmMDLevelOrNone,
dot1agCfmMaCompEntry,
dot1agCfmMepEntry,
dot1agCfmLtrEntry,
dot1agCfmMdIndex,
dot1agCfmMaIndex,
dot1agCfmMepIdentifier,
dot1agCfmMepDbRMepIdentifier
FROM IEEE8021-CFM-MIB
switch
FROM PRVT-SWITCH-MIB
VlanId FROM Q-BRIDGE-MIB -- [RFC4363]
;
prvtCfmMib MODULE-IDENTITY
LAST-UPDATED "201101180000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
" BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"Prvt extension of Connectivity Fault Management module for managing IEEE 802.1ag"
-- revision history
REVISION "201209120000Z"
DESCRIPTION
"Added prvtCfmMepManageCCMTLV"
REVISION "201104180000Z"
DESCRIPTION
"Added prvtCfmMepSuportedRemoteMepsNo"
REVISION "201101180000Z"
DESCRIPTION
"Added AIS/LCK traps"
REVISION "201007080000Z"
DESCRIPTION
"Added prvtCfmMaAisLckVlan table"
REVISION "201004080000Z"
DESCRIPTION
"Changed description for prvtCfmMepAisCondition"
REVISION "201003170000Z"
DESCRIPTION
"Add posibility to enable/disable 1wJitter, 2wJitter, FrameLoss and Latency
on a CFM profile."
REVISION "200906200000Z"
DESCRIPTION
"Fixed some minor description issues, removed prvtCfmProfileFrameLossBucketSize"
REVISION "200808190000Z"
DESCRIPTION
"Added prvtCfmMepTransmitLbmSuccessRate, prvtCfmMepTransmitLbmMinTime,
prvtCfmMepTransmitLbmAvgTime, prvtCfmMepTransmitLbmMaxTime,
prvtCfmLbrBadMsdu."
REVISION "200806240000Z"
DESCRIPTION
"Added prvtCfmStatus"
REVISION "200801200000Z"
DESCRIPTION
"Initial"
::= { switch 131 }
prvtCfmMibNotifications OBJECT IDENTIFIER ::= { prvtCfmMib 0 }
prvtCfmMibObjects OBJECT IDENTIFIER ::= { prvtCfmMib 1 }
prvtCfmMibConformance OBJECT IDENTIFIER ::= { prvtCfmMib 2 }
prvtCfmUpdateInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time between monitoring parameters update (in seconds).
A value of 0 suspends the monitoring task and a
value different from 0 resumes it. Default is 20 seconds."
DEFVAL { 20 }
::= { prvtCfmMibObjects 1 }
prvtCfmStatus OBJECT-TYPE
SYNTAX INTEGER {
enable ( 1 ),
disable ( 2 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable cfm."
::= { prvtCfmMibObjects 2 }
prvtCfmProfile OBJECT IDENTIFIER ::= { prvtCfmMibObjects 3 }
prvtCfmProfileTableNextIndex OBJECT-TYPE
SYNTAX Dot1afCfmIndexIntegerNextFree
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an unused value for prvtCfmProfileIndex in
the prvtCfmProfileTable, or a zero to indicate that none exist."
::= { prvtCfmProfile 1 }
-- ----------------------------------------------------
-- ----------------------------------------------------
prvtCfmProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table contains loopback results from all remote MEPs in the MA."
::= { prvtCfmProfile 2 }
prvtCfmProfileEntry OBJECT-TYPE
SYNTAX PrvtCfmProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "a"
INDEX { prvtCfmProfileIndex }
::= { prvtCfmProfileTable 1 }
PrvtCfmProfileEntry ::= SEQUENCE {
prvtCfmProfileIndex Unsigned32,
prvtCfmProfileName DisplayString,
prvtCfmProfilePriority Unsigned32,
prvtCfmProfileRate Unsigned32,
prvtCfmProfileSize Unsigned32,
prvtCfmProfileBucketSize Unsigned32,
prvtCfmProfile1wJitterError Unsigned32,
prvtCfmProfile1wJitterWarning Unsigned32,
prvtCfmProfileJitterError Unsigned32,
prvtCfmProfileJitterErrorPeriod Unsigned32,
prvtCfmProfileJitterWarning Unsigned32,
prvtCfmProfileJitterWarningPeriod Unsigned32,
prvtCfmProfileFrameLossError Unsigned32,
prvtCfmProfileFrameLossWarning Unsigned32,
prvtCfmProfileLatencyError Unsigned32,
prvtCfmProfileLatencyErrorPeriod Unsigned32,
prvtCfmProfileLatencyWarning Unsigned32,
prvtCfmProfileLatencyWarningPeriod Unsigned32,
prvtCfmProfileRowStatus RowStatus,
prvtCfmProfile1wJitterEnable TruthValue,
prvtCfmProfileJitterEnable TruthValue,
prvtCfmProfileFrameLossEnable TruthValue,
prvtCfmProfileLatencyEnable TruthValue
}
prvtCfmProfileIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table index."
::= { prvtCfmProfileEntry 1 }
prvtCfmProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile name."
::= { prvtCfmProfileEntry 2 }
prvtCfmProfilePriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"802.1p class-of-service setting."
DEFVAL { 0 }
::= { prvtCfmProfileEntry 3 }
prvtCfmProfileRate OBJECT-TYPE
SYNTAX Unsigned32 (1..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of Request packets to send each time."
DEFVAL { 1 }
::= { prvtCfmProfileEntry 4 }
prvtCfmProfileSize OBJECT-TYPE
SYNTAX Unsigned32 (0..1462)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Size of data TLV included in probe packets (in octets)."
DEFVAL { 0 }
::= { prvtCfmProfileEntry 5 }
prvtCfmProfileBucketSize OBJECT-TYPE
SYNTAX Unsigned32 (2..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of the results to save for results calculation."
DEFVAL { 20 }
::= { prvtCfmProfileEntry 6 }
prvtCfmProfile1wJitterError OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies one-way jitter error values to monitor in milliseconds."
DEFVAL { 350 }
::= { prvtCfmProfileEntry 7 }
prvtCfmProfile1wJitterWarning OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies one-way jitter warning values to monitor in milliseconds."
DEFVAL { 300 }
::= { prvtCfmProfileEntry 8 }
prvtCfmProfileJitterError OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies round-trip jitter error values to monitor in milliseconds."
DEFVAL { 700 }
::= { prvtCfmProfileEntry 9 }
prvtCfmProfileJitterErrorPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the duration jitter occurs in seconds."
DEFVAL { 90 }
::= { prvtCfmProfileEntry 10 }
prvtCfmProfileJitterWarning OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies round-trip jitter warning values
to monitor in milliseconds. If set value is greater than the
jitter-error it means that the warning is disabled."
DEFVAL { 600 }
::= { prvtCfmProfileEntry 11 }
prvtCfmProfileJitterWarningPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the duration jitter occurs in seconds."
DEFVAL { 180 }
::= { prvtCfmProfileEntry 12 }
prvtCfmProfileFrameLossError OBJECT-TYPE
SYNTAX Unsigned32 (0..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies round-trip frame-loss error
values to monitor. The default is
frame-loss of 10% is reported."
DEFVAL { 10 }
::= { prvtCfmProfileEntry 13 }
prvtCfmProfileFrameLossWarning OBJECT-TYPE
SYNTAX Unsigned32 (0..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies round-trip frame-loss warning
values to monitor. The default is frame-loss
of 8% is reported. If set value is greater
than the frame-loss-error it means
that the warning is disable."
DEFVAL { 8 }
::= { prvtCfmProfileEntry 14 }
prvtCfmProfileLatencyError OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies round-trip latency error values to monitor in milliseconds."
DEFVAL { 2000 }
::= { prvtCfmProfileEntry 15 }
prvtCfmProfileLatencyErrorPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the duration latency increase occurs in seconds."
DEFVAL { 90 }
::= { prvtCfmProfileEntry 16 }
prvtCfmProfileLatencyWarning OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies round-trip latency error values to
monitor in milliseconds. If set value is greater than the
latency-error it means that the warning is disabled."
DEFVAL { 1600 }
::= { prvtCfmProfileEntry 17 }
prvtCfmProfileLatencyWarningPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the duration latency increase occurs in seconds."
DEFVAL { 180 }
::= { prvtCfmProfileEntry 18 }
prvtCfmProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns must have a valid value before a row
can be activated.
"
::= { prvtCfmProfileEntry 19 }
prvtCfmProfile1wJitterEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A boolean showing if one way jitter calculation is enabled."
DEFVAL { true }
::= { prvtCfmProfileEntry 20 }
prvtCfmProfileJitterEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A boolean showing if two way jitter calculation is enabled."
DEFVAL { true }
::= { prvtCfmProfileEntry 21 }
prvtCfmProfileFrameLossEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A boolean showing if frame loss calculation is enabled."
DEFVAL { true }
::= { prvtCfmProfileEntry 22 }
prvtCfmProfileLatencyEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A boolean showing if latency calculation is enabled."
DEFVAL { true }
::= { prvtCfmProfileEntry 23 }
prvtCfmProcess OBJECT IDENTIFIER ::= { prvtCfmMibObjects 4 }
prvtCfmProcessTableNextIndex OBJECT-TYPE
SYNTAX Dot1afCfmIndexIntegerNextFree
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an unused value for prvtCfmProcessIndex in
the prvtCfmProcessTable, or a zero to indicate that none exists."
::= { prvtCfmProcess 1 }
-- ----------------------------------------------------
-- ----------------------------------------------------
prvtCfmProcessTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Private extension of dot1agCfmMaNetTable.
Controls the two-way monitoring process
for MEP's in the MA."
::= { prvtCfmProcess 2 }
prvtCfmProcessEntry OBJECT-TYPE
SYNTAX PrvtCfmProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "a"
INDEX { dot1agCfmMdIndex, dot1agCfmMaIndex, prvtCfmProcessIndex }
::= { prvtCfmProcessTable 1 }
PrvtCfmProcessEntry ::= SEQUENCE {
prvtCfmProcessIndex Unsigned32,
prvtCfmProcessProfileIndex Unsigned32,
prvtCfmProcessName OCTET STRING,
prvtCfmProcessStatus TruthValue,
prvtCfmProcessRepeatInterval Unsigned32,
prvtCfmProcessPacketType INTEGER,
prvtCfmProcessUnreturnedPkts Unsigned32,
prvtCfmProcessRowStatus RowStatus
}
prvtCfmProcessIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table index."
::= { prvtCfmProcessEntry 1 }
prvtCfmProcessProfileIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Index of the monitoring profile to be used."
DEFVAL { 1 }
::= { prvtCfmProcessEntry 2 }
prvtCfmProcessName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The name of the process. Should be unique per domain/MA"
::= { prvtCfmProcessEntry 3 }
prvtCfmProcessStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable two-way monitoring process for MEP's in the MA."
DEFVAL { true }
::= { prvtCfmProcessEntry 4 }
prvtCfmProcessRepeatInterval OBJECT-TYPE
SYNTAX Unsigned32 (1..420)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Repeating frequency of the monitoring process."
DEFVAL { 60 }
::= { prvtCfmProcessEntry 5 }
prvtCfmProcessPacketType OBJECT-TYPE
SYNTAX INTEGER {
cfm (1),
y1731 (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Use CFM Loopback or Y.1731 LMMs and DMMs packets."
DEFVAL { cfm }
::= { prvtCfmProcessEntry 6 }
prvtCfmProcessUnreturnedPkts OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of requests for which a reply hasn't been
received. These packets will be counted as lost
when they enter timeout."
DEFVAL { 0 }
::= { prvtCfmProcessEntry 7 }
prvtCfmProcessRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns must have a valid value before a row
can be activated."
::= { prvtCfmProcessEntry 8 }
-- ------------------------------------------------
-- ------------------------------------------------
prvtCfmProcessResult OBJECT IDENTIFIER ::= { prvtCfmMibObjects 5 }
prvtCfmProcessResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmProcessResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table contains process results."
::= { prvtCfmProcessResult 1 }
prvtCfmProcessResultEntry OBJECT-TYPE
SYNTAX PrvtCfmProcessResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "a"
INDEX { dot1agCfmMdIndex, dot1agCfmMaIndex,
prvtCfmProcessIndex, dot1agCfmMepDbRMepIdentifier }
::= { prvtCfmProcessResultTable 1 }
PrvtCfmProcessResultEntry ::= SEQUENCE {
prvtCfmProcessResultOneWayJitter Unsigned32,
prvtCfmProcessResultTwoWayJitter Unsigned32,
prvtCfmProcessResultLatency Unsigned32,
prvtCfmProcessResultFrameloss Unsigned32
}
prvtCfmProcessResultOneWayJitter OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One way jitter calculated for a specific remote MEP in milliseconds"
::= { prvtCfmProcessResultEntry 1 }
prvtCfmProcessResultTwoWayJitter OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Two way jitter calculated for a specific remote MEP in milliseconds"
::= { prvtCfmProcessResultEntry 2 }
prvtCfmProcessResultLatency OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Two way latency calculated for a specific remote MEP
in milliseconds"
::= { prvtCfmProcessResultEntry 3 }
prvtCfmProcessResultFrameloss OBJECT-TYPE
SYNTAX Unsigned32 (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Two way frameloss calculated for a specific remote MEP
in units of hundredths of percent.
Note: When prvtCfmProcessResultFrameloss has value of 10000, all the values of
prvtCfmProcessResultOneWayJitter, prvtCfmProcessResultTwoWayJitter and
prvtCfmProcessResultLatency are irrelevant."
::= { prvtCfmProcessResultEntry 4 }
-- ------------------------------------------------
-- ------------------------------------------------
prvtCfmMa OBJECT IDENTIFIER ::= { prvtCfmMibObjects 6 }
prvtCfmMaTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmMaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table includes extra variables needed for Y.1731
support and service awareness"
::= { prvtCfmMa 1 }
prvtCfmMaEntry OBJECT-TYPE
SYNTAX PrvtCfmMaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "a"
AUGMENTS { dot1agCfmMaCompEntry }
::= { prvtCfmMaTable 1 }
PrvtCfmMaEntry ::= SEQUENCE {
prvtCfmMaCompAisLckEnabled TruthValue,
prvtCfmMaCompAisLckLevel Dot1agCfmMDLevelOrNone,
prvtCfmMaCompAisLckInterval INTEGER,
prvtCfmMaCompAisLckPriority Unsigned32,
prvtCfmMaCompServiceId Unsigned32,
prvtCfmMaCompNumberOfServices Unsigned32,
prvtCfmMaCompClearConnectivity Unsigned32
}
prvtCfmMaCompAisLckEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Turn the AIS & LCK features on/off."
DEFVAL { false }
::= { prvtCfmMaEntry 1 }
prvtCfmMaCompAisLckLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevelOrNone
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MD level at which AIS & LCK frames will be sent.
It should be greater then that of the current domain.
The default value is '-1' representing 'not-configured'."
DEFVAL {-1}
::= { prvtCfmMaEntry 2 }
prvtCfmMaCompAisLckInterval OBJECT-TYPE
SYNTAX INTEGER {
interval1s (1),
interval1min (2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time interval at which AIS and LCK frames will be sent"
DEFVAL { interval1s }
::= { prvtCfmMaEntry 3 }
prvtCfmMaCompAisLckPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"COS parameter for the outgoing AIS & LCK frames.
The default value is '6'"
DEFVAL { 6 }
::= { prvtCfmMaEntry 4 }
prvtCfmMaCompServiceId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The primary service ID attached to this MA"
DEFVAL { 0 }
::= { prvtCfmMaEntry 5 }
prvtCfmMaCompNumberOfServices OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of services attached to this MA"
DEFVAL { 1 }
::= { prvtCfmMaEntry 6 }
prvtCfmMaCompClearConnectivity OBJECT-TYPE
SYNTAX Unsigned32 (0..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of MEP or 0 for all"
DEFVAL { 0 }
::= { prvtCfmMaEntry 7 }
-- ----------------------------------------------------
-- ----------------------------------------------------
prvtCfmMep OBJECT IDENTIFIER ::= { prvtCfmMibObjects 7 }
prvtCfmMepTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "a"
::= { prvtCfmMep 1 }
prvtCfmMepEntry OBJECT-TYPE
SYNTAX PrvtCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "a"
AUGMENTS { dot1agCfmMepEntry }
::= { prvtCfmMepTable 1 }
PrvtCfmMepEntry ::= SEQUENCE {
prvtCfmMepAlarmSupressed TruthValue,
prvtCfmMepAisCondition TruthValue,
prvtCfmMepLckCondition TruthValue,
prvtCfmMepAisLifetime INTEGER,
prvtCfmMepLckLifetime INTEGER,
prvtCfmMepTransmitMcastLbm TruthValue,
prvtCfmMepTransmitLbmInfinite TruthValue,
prvtCfmMepTransmitLbmDelay Unsigned32,
prvtCfmMepTransmitLbmTimeout Unsigned32,
prvtCfmMepTransmitLtmTimeout Unsigned32,
prvtCfmMepTransmitLbmSentPkts Unsigned32,
prvtCfmMepTransmitLbmSuccessRate Unsigned32,
prvtCfmMepTransmitLbmMinTime Unsigned32,
prvtCfmMepTransmitLbmAvgTime Unsigned32,
prvtCfmMepTransmitLbmMaxTime Unsigned32,
prvtCfmMepSuportedRemoteMepsNo INTEGER,
prvtCfmMepExcludeCCMTLV DisplayString
}
prvtCfmMepAlarmSupressed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A boolean showing if an AIS or LCK packet
was received from a lower level"
DEFVAL { false }
::= { prvtCfmMepEntry 1 }
prvtCfmMepAisCondition OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A boolean showing if there is AIS condition. The value of the object is true (an AIS condition), when
there is a detection of signal-fail condition at a Server layer or reception of AIS at a server (sub-) layer MEP [AIS condition/Rec.
ITU-T Y.1731].
The AIS condition will exit when following criteria is met: During an interval equal to 3.5 times the AIS transmission
period indicated in the AIS frames received earlier, the MEP does not receive AIS frames or, when ETH-CC is used,
upon clearing of LOC defect at MEP /Appendix I/Rec. ITU-T Y.1731.
If prvtCfmMaCompAisLckLevel is configured the MEP should send AIS packets."
DEFVAL { false }
::= { prvtCfmMepEntry 2 }
prvtCfmMepLckCondition OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A boolean showing if the MEP should lock the service
towards the client and send LCK packets"
DEFVAL { false }
::= { prvtCfmMepEntry 3 }
prvtCfmMepAisLifetime OBJECT-TYPE
SYNTAX INTEGER {
nolifetime (0),
lifetime35s (1),
lifetime35min (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lifetime of the last received AIS packet.
During an interval equal to 3.5 times the AIS transmission period indicated
in the AIS frames received earlier, the MEP does not receive AIS frames.
The value is valid (non-zero) if AIS packets are being received."
::= { prvtCfmMepEntry 4 }
prvtCfmMepLckLifetime OBJECT-TYPE
SYNTAX INTEGER {
nolifetime (0),
lifetime35s (1),
lifetime35min (2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lifetime of the last received LCK packet.
During an interval equal to 3.5 times the LCK transmission period indicated
in the LCK frames received earlier, the MEP does not receive LCK frames.
The value is valid (non-zero) if AIS packets are being received."
::= { prvtCfmMepEntry 5 }
prvtCfmMepTransmitMcastLbm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A boolean to control sending Y.1731 multicast loopback."
DEFVAL { false }
::= { prvtCfmMepEntry 6 }
prvtCfmMepTransmitLbmInfinite OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A boolean to control sending LBMs continuously until the
operation is explicitly stopped by setting this back to false"
DEFVAL { false }
::= { prvtCfmMepEntry 7 }
prvtCfmMepTransmitLbmDelay OBJECT-TYPE
SYNTAX Unsigned32 (0..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An amount of time to wait between sent LBMs (in seconds)."
DEFVAL { 1 }
::= { prvtCfmMepEntry 8 }
prvtCfmMepTransmitLbmTimeout OBJECT-TYPE
SYNTAX Unsigned32 (1..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An amount of time to wait after the last sent LBM if no
LBR is received (in seconds)."
DEFVAL { 5 }
::= { prvtCfmMepEntry 9 }
prvtCfmMepTransmitLtmTimeout OBJECT-TYPE
SYNTAX Unsigned32 (1..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An amount of time to wait after the last sent LTM if no
LTR is received (in seconds)."
DEFVAL { 5 }
::= { prvtCfmMepEntry 10 }
prvtCfmMepTransmitLbmSentPkts OBJECT-TYPE
SYNTAX Unsigned32 (1..1024)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of successfully sent packets in the current LBM
session."
::= { prvtCfmMepEntry 11 }
prvtCfmMepTransmitLbmSuccessRate OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Success rate of the current LBM session (in percentage*100)."
::= { prvtCfmMepEntry 12 }
prvtCfmMepTransmitLbmMinTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum LBR response time (in msec)."
::= { prvtCfmMepEntry 13 }
prvtCfmMepTransmitLbmAvgTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average LBR response time (in msec)."
::= { prvtCfmMepEntry 14 }
prvtCfmMepTransmitLbmMaxTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum LBR response time (in msec)."
::= { prvtCfmMepEntry 15 }
prvtCfmMepSuportedRemoteMepsNo OBJECT-TYPE
SYNTAX INTEGER{
remoteMeps8 (8),
remoteMeps16 (16),
remoteMeps24 (24),
remoteMeps32 (32)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of suported remote meps (for TMarc3x0 and TMarc280 devices)"
DEFVAL {remoteMeps8}
::= { prvtCfmMepEntry 16 }
prvtCfmMepExcludeCCMTLV OBJECT-TYPE
SYNTAX DisplayString (SIZE(2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bitmask that specifies what TLVs should be excluded(for TMarc3x0 and TMarc280 devices):
On set opertaion:
BIT4 = MSB Include/Exclude bit - if it is 1 the tlv is excluded from the specific CCM packet,if it is 0 the tlv will be included in the specific CCM packet
BIT3 = If set 1 the OrgSpecific TLV will be excluded or included
BIT2 = If set 1 the InterfaceStatus TLV will be excluded or included
BIT1 = If set 1 the PortStatus TLV will be excluded or included
BIT0 = LSB If set 1 the Sender ID TLV will be excluded or included
Examples:
If Interface Status and Port Status will be excluded the bitmask will look like this:
16 in hexadecimal BIT4 BIT3 BIT2 BIT1 BIT0
1 0 1 1 0
If Interface Status and Port Status will be included the bitmask will look like this:
06 in hexadecimal BIT4 BIT3 BIT2 BIT1 BIT0
0 0 1 1 0
On get operation it shows the bits corresponding to the excluded tlvs
If Interface Status and Port Status are excluded:
06 in hexadecimal - 0 1 1 0
"
::= { prvtCfmMepEntry 17 }
-- ------------------------------------------------
-- ------------------------------------------------
prvtCfmLbrTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmLbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table contains loopback results following the last loopback operation."
::= { prvtCfmMep 2 }
prvtCfmLbrEntry OBJECT-TYPE
SYNTAX PrvtCfmLbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "a"
INDEX { dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier,
prvtCfmLbrSeqNumber, prvtCfmLbrReceiveOrder }
::= { prvtCfmLbrTable 1 }
PrvtCfmLbrEntry ::= SEQUENCE {
prvtCfmLbrSeqNumber Unsigned32,
prvtCfmLbrReceiveOrder Unsigned32,
prvtCfmLbrTime Unsigned32,
prvtCfmLbrMacAddress MacAddress,
prvtCfmLbrBadMsdu TruthValue
}
prvtCfmLbrSeqNumber OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Transaction identifier/Sequence number of the received LBR."
::= { prvtCfmLbrEntry 1}
prvtCfmLbrReceiveOrder OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index to distinguish among multiple LBRs with the same LBR
Transaction Identifier field value. This situation can appear
in the case of multicast loopback.
"
::= { prvtCfmLbrEntry 2 }
prvtCfmLbrTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote MEPs response time in milliseconds."
::= { prvtCfmLbrEntry 3 }
prvtCfmLbrMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote MEPs mac address. For unicast loopback
this is the same as dot1agCfmMepTransmitLbmDestMacAddress,
but for multicast loopback there will be different entries."
::= { prvtCfmLbrEntry 4 }
prvtCfmLbrBadMsdu OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result of the Data TLV verification."
::= { prvtCfmLbrEntry 5 }
-- ------------------------------------------------
-- ------------------------------------------------
prvtCfmLtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmLtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table adds the possibility to measure the response
time to a linktrace request."
::= { prvtCfmMep 3 }
prvtCfmLtrEntry OBJECT-TYPE
SYNTAX PrvtCfmLtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "a"
AUGMENTS { dot1agCfmLtrEntry }
::= { prvtCfmLtrTable 1 }
PrvtCfmLtrEntry ::= SEQUENCE {
prvtCfmLtrTime Unsigned32
}
prvtCfmLtrTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote MPs response time in milliseconds."
::= { prvtCfmLtrEntry 1 }
-- ----------------------------------------------------
-- ----------------------------------------------------
prvtCfmMaAisLckVlan OBJECT IDENTIFIER ::= { prvtCfmMibObjects 8 }
prvtCfmMaAisLckVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmMaAisLckVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table includes extra variables needed for AIS/LCK configurable vlans"
::= { prvtCfmMaAisLckVlan 1 }
prvtCfmMaAisLckVlanEntry OBJECT-TYPE
SYNTAX PrvtCfmMaAisLckVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table includes extra variables needed for AIS/LCK configurable vlans"
INDEX {dot1agCfmMdIndex, dot1agCfmMaIndex, prvtCfmMaAisLckVlanId }
::= { prvtCfmMaAisLckVlanTable 1 }
PrvtCfmMaAisLckVlanEntry ::= SEQUENCE {
prvtCfmMaAisLckVlanId VlanId,
prvtCfmMaAisLckVlanRowStatus RowStatus
}
prvtCfmMaAisLckVlanId OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Vlan ID (towards customer level) that the generated AIS/LCK packets should use."
::= { prvtCfmMaAisLckVlanEntry 1 }
prvtCfmMaAisLckVlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row."
::= { prvtCfmMaAisLckVlanEntry 2 }
-- ------------------------------------------------
-- ------------------------------------------------
-- ***********************************************
-- **************** Notification *****************
-- ***********************************************
prvtCfm1wJitterThreshold NOTIFICATION-TYPE
OBJECTS {
prvtCfmProcessResultOneWayJitter,
prvtCfmProfile1wJitterWarning,
prvtCfmProfile1wJitterError
}
STATUS current
DESCRIPTION
"This trap should be sent whenever the one way jitter
on a CFM test will surpass one of the 2 defined thresholds."
::= { prvtCfmMibNotifications 1 }
prvtCfmJitterThreshold NOTIFICATION-TYPE
OBJECTS {
prvtCfmProcessResultTwoWayJitter,
prvtCfmProfileJitterWarning,
prvtCfmProfileJitterWarningPeriod,
prvtCfmProfileJitterError,
prvtCfmProfileJitterErrorPeriod
}
STATUS current
DESCRIPTION
"This trap should be sent whenever the two way jitter
on a CFM test will surpass one of the 2 defined thresholds."
::= { prvtCfmMibNotifications 2 }
prvtCfmFrameLossThreshold NOTIFICATION-TYPE
OBJECTS {
prvtCfmProcessResultFrameloss,
prvtCfmProfileFrameLossWarning,
prvtCfmProfileFrameLossError
}
STATUS current
DESCRIPTION
"This trap should be sent whenever the frame loss
on a CFM test will surpass one of the 2 defined
thresholds."
::= { prvtCfmMibNotifications 3 }
prvtCfmLatencyThreshold NOTIFICATION-TYPE
OBJECTS {
prvtCfmProcessResultLatency,
prvtCfmProfileLatencyWarning,
prvtCfmProfileLatencyWarningPeriod,
prvtCfmProfileLatencyError,
prvtCfmProfileLatencyErrorPeriod
}
STATUS current
DESCRIPTION
"This trap should be sent whenever the latency
on a CFM test will surpass one of the 2 defined
thresholds."
::= { prvtCfmMibNotifications 4 }
prvtCfmAisReceived NOTIFICATION-TYPE
OBJECTS {
prvtCfmMepAisLifetime
}
STATUS current
DESCRIPTION
"This trap is issued whenever an AIS condition with specified lifetime on a MEP is met."
::= { prvtCfmMibNotifications 5 }
prvtCfmLckReceived NOTIFICATION-TYPE
OBJECTS {
prvtCfmMepLckLifetime
}
STATUS current
DESCRIPTION
"This trap is issued whenever an LCK condition with specified lifetime on a MEP is met."
::= { prvtCfmMibNotifications 6 }
END