mibs/MIBS/telco-systems/binos/PRVT-INTERWORKING-OS-MIB

840 lines
22 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: prvt-interworking-os-mib.mib
-- *********************************************************************
-- (c) Copyright, 1998, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
--
PRVT-INTERWORKING-OS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
IpAddress,
Integer32
FROM SNMPv2-SMI
DisplayString,
TruthValue,
MacAddress
FROM SNMPv2-TC
NOTIFICATION-TYPE
FROM SNMPv2-SMI
prvt-products
FROM PRVT-SWITCH-MIB
usmUserSecurityName
FROM SNMP-USER-BASED-SM-MIB;
prvtInterworkOsMib MODULE-IDENTITY
LAST-UPDATED "200804090000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"The MIB enables display configuration of the device OS features."
-- revision history
REVISION "200804090000Z"
DESCRIPTION
"setExecutetrap varbind change"
REVISION "200803310000Z"
DESCRIPTION
"Removed configurationChanged, see PrvtConfigChange.mib."
REVISION "200801010000Z"
DESCRIPTION
"Removed redefined OIDs in private vendor extension definitions."
REVISION "200502160000Z"
DESCRIPTION
"Fixed spelling errors and changed the contact info."
REVISION "200412200000Z"
DESCRIPTION
"Added the configurationChanged and snmpSetExecuted notifications."
REVISION "200403100000Z"
DESCRIPTION
"Modified the description of the managementLoadExecute object
to clarify that the startup-config is replaced at
configuration download."
REVISION "200305080000Z"
DESCRIPTION
"Move to SMI-V2."
REVISION "200212120000Z"
DESCRIPTION
"Add detection for CPU RAM size."
REVISION "200211260000Z"
DESCRIPTION
"Add CPU group."
REVISION "200211170000Z"
DESCRIPTION
"Enable loading VDSL E2 firmware.
Add support for reload."
REVISION "200104190000Z"
DESCRIPTION
"Add management group."
REVISION "200103190000Z"
DESCRIPTION
"Initial version."
::= { software 1 }
software OBJECT IDENTIFIER ::= { prvt-products 111 }
prvtInterworkOsNotifications OBJECT IDENTIFIER ::= { prvtInterworkOsMib 0 }
version OBJECT IDENTIFIER ::= {prvtInterworkOsMib 1}
option OBJECT IDENTIFIER ::= {prvtInterworkOsMib 2}
management OBJECT IDENTIFIER ::= {prvtInterworkOsMib 3}
cpu OBJECT IDENTIFIER ::= {prvtInterworkOsMib 4}
prvtInterworkOsConformance OBJECT IDENTIFIER ::= { prvtInterworkOsMib 5 }
--
-- version group
--
bootVersionNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies version number of the Boot program"
::= { version 1 }
bootVersionDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies creation date/time of the Boot program"
::= { version 2 }
bootVersionString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains text for the current version of the Boot program"
::= { version 3 }
oSversionNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies version number of the OS"
::= { version 4 }
oSversionDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies creation date/time of the OS"
::= { version 5 }
oSversionString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains text for the current version of the OS"
::= { version 6 }
appletVersionNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains text for the current version of the embedded
applet"
::= { version 7 }
appletVersionDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains text for the creation date of the current embedded
applet version"
::= { version 8 }
--
-- option group
--
optionInstalled OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies creation date/time of the OS"
::= { option 1 }
--
-- management group
--
--
-- Connectivity Information
--
-- This group is meant to be a collection of controls and data
-- for connectivity.
--
managementConnectivity OBJECT IDENTIFIER ::= {management 1}
managementConnectivityMACAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Get the agent MAC address."
::= { managementConnectivity 1 }
managementConnectivityIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IP Address for the device."
::= { managementConnectivity 2 }
managementConnectivityIPNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IP NetMask for the device."
::= { managementConnectivity 3 }
managementIPGateAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set Gateway Address for the device - only applies for devices without
L3 capabilities."
::= { managementConnectivity 4 }
managementSerialBaud OBJECT-TYPE
SYNTAX INTEGER {
baud2400(1),
baud9600(2),
baud19200(3),
baud38400(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Serial port BAUD Rate. Attributes are 8 Start Bits,
no parity, and 1 stop bits (8N1) and Hardware Flow Control.
Valid values are 2400, 9600, 19200, and 38400."
::= { managementConnectivity 5 }
--
-- managementLoad Group
--
-- This group is meant to be a collection of controls and data
-- that determine the file download and upload configuration
-- and mode.
--
managementLoad OBJECT IDENTIFIER ::= {management 2}
managementLoadTftpServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set IP Address for the TFTP server used for downloading
and uploading files."
::= { managementLoad 1 }
managementLoadFileName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set TFTP file path and name."
::= { managementLoad 2 }
managementLoadType OBJECT-TYPE
SYNTAX INTEGER {
application(1),
boot(2),
configuration(3),
java(4),
vdsl-E2(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of file to download or upload
upon a managementLoadExecute."
::= { managementLoad 3 }
managementLoadExecute OBJECT-TYPE
SYNTAX INTEGER {
noop(1), -- no operation
download(2), -- Application, Boot, java or Configuration
upload(3) -- Configuration only
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Execute file download or upload procedure. A SET of this
object starts the load procedure. Note that the Application
and Boot images can only be downloaded. The Configuration
file can be uploaded and downloaded. When a Configuration file
is downloaded, it replaces the startup-config file in NVRAM.
A GET of this object will return a noop (1). Also, when the user chooses to
upload the configuration, it is the startup-config that is copied to the remote host.
Use managementLoadExecuteStatus to determine the status of the executed load."
::= { managementLoad 4 }
managementLoadExecuteStatus OBJECT-TYPE
SYNTAX INTEGER {
not-started(1),
in-progress(2),
success(3),
error-connection(4),
error-filename(5),
error-fault(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Provides status on the execute file load procedure.
The status return is given by one of the enumerated codes
not-started (download has not yet started)
in-progress (download has not yet finished)
success (download has finished successfully)
error-connection (download cannot connect)
error-filename (download has bad image path/filename)
error-fault (download has fault condition on device)."
::= { managementLoad 5 }
--
-- Miscellaneous Information
--
-- This group is meant to be a collection of controls and data
-- that do not require a group of their own, or fall into the
-- category of "miscellaneous".
--
managementMisc OBJECT IDENTIFIER ::= {management 3}
managementMiscSaveToNvm OBJECT-TYPE
SYNTAX INTEGER {
noop(1), -- no operation
save(2) -- save all configuration parameters to NVM
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to save (2), all nonvolatile configuration
parameters are saved to NVM (Nonvolatile Memory). NVM save
operations may be slow (e.g., erasing/writing Flash device).
Consequently, all (or many) updates should be made before
saving to NVM. A get operation always returns noop (1)"
::= { managementMisc 1 }
managementMiscReset OBJECT-TYPE
SYNTAX INTEGER {
noop(1),
reset(2),
reset-to-defaults(3),
save-and-reset(4) -- save config and then reset the unit
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Physically performs a hardware reset of the unit.
Use with care. A reset (2) resets the unit, the
reset-to-defaults (3) resets the configuration file
to factory defaults and then resets the unit, the value of
save-and-reset (4) saves the config and then resets the unit and
noop (1) does nothing.
A value of noop (1) is always returned
for a GET operation."
::= { managementMisc 2 }
managementMiscReload OBJECT-TYPE
SYNTAX INTEGER {
noop(1),
save-and-reload(2) -- save config and then reload the software
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reload the unit software, the unit hardware will not
be affected. A value of noop (1) is always returned for a
GET operation."
::= { managementMisc 3 }
managementMiscReloadInTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates time for scheduled reload without save in hour:min.
octets contents range
1 day 0x01..0x1f (1-31)
2 month 0x01..0x0C (1..12)
where january = 1 december = 12
3 hour 0x01..0x17 (0..23)
4 min 0x01..3B (0..59)
For example: 0x01 0x01 0x01 0x01 means 1 January 01:01.
To stop scheduled reload set it to 0x00 0x00 0x00 0x00"
::= { managementMisc 4 }
managementMiscReloadAtTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates time for scheduled reload without save at day:month:hour:min.
octets contents range
1 day 0x01..0x1f (1-31)
2 month 0x01..0x0C (1..12)
where january = 1 december = 12
3 hour 0x01..0x17 (0..23)
4 min 0x01..3B (0..59)
For example: 0x01 0x01 0x01 0x01 means 1 January 01:01.
To stop scheduled reload set it to 0x00 0x00 0x00 0x00"
::= { managementMisc 5 }
managementMiscReloadSaveInTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates time for scheduled reload with save in hour:min.
octets contents range
1 day 0x01..0x1f (1-31)
2 month 0x01..0x0C (1..12)
where january = 1 december = 12
3 hour 0x01..0x17 (0..23)
4 min 0x01..3B (0..59)
For example: 0x01 0x01 0x01 0x01 means 1 January 01:01.
To stop scheduled reload set it to 0x00 0x00 0x00 0x00"
::= { managementMisc 6 }
managementMiscReloadSaveAtTime OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates time for scheduled reload with save at day:month:hour:min.
octets contents range
1 day 0x01..0x1f (1-31)
2 month 0x01..0x0C (1..12)
where january = 1 december = 12
3 hour 0x01..0x17 (0..23)
4 min 0x01..3B (0..59)
For example: 0x01 0x01 0x01 0x01 means 1 January 01:01.
To stop scheduled reload set it to 0x00 0x00 0x00 0x00"
::= { managementMisc 7 }
managementLicense OBJECT IDENTIFIER ::= {management 4}
managementOptionSupportStatus OBJECT-TYPE
SYNTAX INTEGER { reserved0 (0), -- reserved
reserved1 (1), -- reserved
reserved2 (2), -- reserved
reserved3 (3), -- reserved
reserved4 (4), -- reserved
reserved5 (5), -- reserved
reserved6 (6), -- reserved
reserved7 (7), -- reserved
reserved8 (8), -- reserved
reserved9 (9), -- reserved
licNotSpecified(10), -- the device is without license
licBasic(11), -- SWITCH license registered
licML(12), -- ML license
licAdvML(13), -- Adv-ML license
reserved14 (14), -- reserved
reserved15 (15), -- reserved
reserved16 (16), -- reserved
reserved17 (17), -- reserved
reserved18 (18), -- reserved
reserved19 (19), -- reserved
reserved20 (20), -- reserved
reserved21 (21), -- reserved
reserved22 (22), -- reserved
reserved23 (23), -- reserved
reserved24 (24), -- reserved
reserved25 (25), -- reserved
reserved26 (26), -- reserved
reserved27 (27), -- reserved
reserved28 (28), -- reserved
reserved29 (29), -- reserved
reserved30 (30), -- reserved
reserved31 (31) -- reserved
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates active software support options (license)."
::= { managementLicense 1 }
managementOptionSupportKey OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specify the software support option key (license). After set, device must be reloaded the new option to take affect."
::= { managementLicense 2 }
managementOptionSupportAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Shows the address of SNMP NMS that has configured last the option."
::= { managementLicense 3 }
managementOptionSupportL3Capable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the swicth is capable for L3 features
- true The switch is capable for L3 features
- false The switch is not capable for L3 features
"
DEFVAL { true }
::= { managementLicense 4 }
prvtBootConfigUpgrade OBJECT IDENTIFIER ::= {management 5}
prvtBootUpgradeSrcURI OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object represents an address from where the application
will be copied and used by the device. The address
must be given in a valid URI format. It will be used by all
booting mechnisms as a source from where to find the application.
So it can point to either local folder or remote device.
Example:
tftp://10.3.71.45/MyApps/Imagev1.5.Z
local://Usr/Imagev1.5.Z
If there is no value set, the device will boot with local application
given in prvtBootApplicationNameURI object"
REFERENCE "See rfc3986"
::= { prvtBootConfigUpgrade 1 }
prvtBootApplicationNameURI OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the name of the application to be used by
the network device to boot. The name of the application is given
in URI format to indicate the storage device. Every network device
can have few localy saved application files copied in different
storage devices: local file system, flash etc. The user can choose
one of them by setting the starage device and the application name.
Example:
local://Imagev1.5.Z,
flash://Imagev1.5.Z
If this object is empty, the device will boot from the network using
the remote application given in prvtBootUpgradeSrcURI"
REFERENCE "See rfc3986"
::= { prvtBootConfigUpgrade 2 }
prvtBootConfigURI OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the configuration file's name of a network device.
The value must be set in URI format. It can point to either local or remote
configuration file.
Example:
local://Usr/my_startup.cfg,
ftp://myuser:mypass@netaddress/MyCfgs/startup.cfg
This field is optional. If it is empty, the standart startup config will be used."
REFERENCE "See rfc3986"
::= { prvtBootConfigUpgrade 3 }
prvtBootUpgradeCmd OBJECT-TYPE
SYNTAX INTEGER {
none(0), -- this will be invalid value
ready(1), -- the common return value on get and next requests
apply(2),
applyExec(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field is used to apply the configuration. When a get request is
executed, the returned value should be always ready. When apply(2)
command is executed, the upgrade settings are applied. Alternative,
when applyExec(3) command is executed, the upgrade process is started.
"
DEFVAL { ready }
::= { prvtBootConfigUpgrade 4 }
prvtBootOperStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0), -- invalid value
ready(1),
notReady(2),
upgradeInProgress(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object is used to show the current status of the upgrating process. The
default value is ready(1), indicating that the process is idle. when the value
is set to notReady(2), the device upgrading mechanism is not correctly configured.
upgradeInProgress(3) indicates upgrading process have started and haven't finished
yet."
DEFVAL { ready }
::= { prvtBootConfigUpgrade 5 }
prvtBootErrorCondition OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
genericError(1),
copyFailed(2),
downloadFailed(3),
freeSpaceError(4),
validationFailed(5),
backupFailed(6),
inProgressError(7),
consistencyError(8),
fileSystemError(9),
profileNameError(10),
profileError(11),
fileNameError(12),
pathError(13),
zFileError(14),
cannotFindFile(15),
defApplicationProfileError(16),
configProfileError(17),
bootDevProfileError(18),
ftpServerProfileError(19),
ftpUserProfileError(20),
ftpPassProfileError(21)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object can be used for feedback. How the upgrading process have finished"
DEFVAL{ noError }
::= { prvtBootConfigUpgrade 6 }
--
-- CPU group
--
cpuMonitoring OBJECT IDENTIFIER ::= {cpu 1}
cpuMonitoringStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object shows the status of the CPU monitor"
::= { cpuMonitoring 1 }
cpuMonitoringUtilization OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object shows the current CPU utilization"
::= { cpuMonitoring 2 }
cpuRedundancy OBJECT IDENTIFIER ::= {cpu 2}
cpuHwRedundancySupport OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows if the backplan of this unit support CPU redundancy."
::= { cpuRedundancy 1 }
cpuRedundancyTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpuRedundancyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the CPU redundancy information."
::= { cpuRedundancy 2 }
cpuRedundancyEntry OBJECT-TYPE
SYNTAX CpuRedundancyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about one CPU"
INDEX { cpuId }
::= { cpuRedundancyTable 1 }
CpuRedundancyEntry ::= SEQUENCE {
cpuId Integer32,
cpuName DisplayString,
cpuStatus INTEGER,
cpuRedundancySupport TruthValue,
cpuSWVersionString DisplayString
}
cpuId OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ID of the CPU in the system"
::= { cpuRedundancyEntry 1 }
cpuName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual representation of the CPU"
::= { cpuRedundancyEntry 2 }
cpuStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
standby(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CPU status"
::= { cpuRedundancyEntry 3 }
cpuRedundancySupport OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows if the CPU card supports redundancy."
::= { cpuRedundancyEntry 4 }
cpuSWVersionString OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OS version currently running on the CPU"
::= { cpuRedundancyEntry 5 }
cpuHW OBJECT IDENTIFIER ::= {cpu 3}
cpuRAMsize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the CPU card RAM size"
::= { cpuHW 1 }
-- Notifications for use by prvtInterworkOsMib
imageCrcCheckFailed NOTIFICATION-TYPE
OBJECTS { managementLoadTftpServerAddress, managementLoadFileName}
STATUS current
DESCRIPTION
"The imageCrcCheckFailed notification indicates that the
image loaded via TFTP has not passed the CRC check
and has been discarded."
::= {prvtInterworkOsNotifications 1}
configurationLoadFailed NOTIFICATION-TYPE
OBJECTS { managementLoadTftpServerAddress, managementLoadFileName}
STATUS current
DESCRIPTION
"The configurationLoadFailed notification indicates that
the sending agent did not succeed to upload or download
the configuration file."
::= {prvtInterworkOsNotifications 2}
unauthorizedAccessViaCLI NOTIFICATION-TYPE
-- OBJECTS { }
STATUS current
DESCRIPTION
"The unauthorizedAccessViaCLI notification indicates that
the last attempt to login to the device via CLI cannot
be authorized."
::= {prvtInterworkOsNotifications 3}
snmpSetExecuted NOTIFICATION-TYPE
OBJECTS { usmUserSecurityName }
STATUS current
DESCRIPTION
"This notification indicates that a successful set request has been performed."
::= {prvtInterworkOsNotifications 4}
managementOptionSupportChanged NOTIFICATION-TYPE
OBJECTS { managementOptionSupportStatus, managementOptionSupportAddress}
STATUS current
DESCRIPTION
"This notification indicates that a management option license has been changed."
::= {prvtInterworkOsNotifications 5}
END