-- ** Filename: PRVT-NETWORK-LOOPBACK-TEST-MIB
-- ** Project: Network Loopback Tester
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications.
-- BATM Advanced Communications retains all title and
-- ownership in the Specification, including any revisions.
-- BATM Advanced Communications grants all interested parties a non-exclusive
-- license to use and distribute an unmodified copy of this
-- Specification in connection with management of BATM Advanced Communications
-- and Telco Systems<6D>products, and without fee, provided that the following
-- conditions are met:
-- 1. Redistributions of this specification must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
-- or promote products derived from this specification without specific prior written
-- permission.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
PRVT-NETWORK-LOOPBACK-TEST-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE
FROM SNMPv2-SMI
ifIndex
FROM IF-MIB
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
TimeStamp,
RowStatus
FROM SNMPv2-TC
NOTIFICATION-TYPE
FROM SNMPv2-SMI -- [RFC2578]
accessListControlListGroup
FROM PRVT-SWITCH-ACCESS-LIST-MIB
ipSwitch FROM PRVT-SWITCH-MIB;
-- The NETWORK LOOPBACK TEST MIB
prvtNetworkLoopbackTestMib MODULE-IDENTITY
LAST-UPDATED "201008310000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"This MIB contains managed objects definitions for
encapsulating Loopback Tester feature that enables or disables
embedded mechanisms for network troubleshooting, diagnostics and measurement."
REVISION "201008310000Z"
DESCRIPTION
"Initial version."
::= { ipSwitch 7 }
prvtNetworkLoopbackTestNotifications OBJECT IDENTIFIER ::= { prvtNetworkLoopbackTestMib 0 }
prvtNetworkLoopbackTestObjects OBJECT IDENTIFIER ::= { prvtNetworkLoopbackTestMib 1 }
prvtNetworkLoopbackTestConformance OBJECT IDENTIFIER ::= { prvtNetworkLoopbackTestMib 2 }
prvtNetworkLoopbackTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtNetworkLoopbackTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains object for configuring and display information about Network Loopback Tester."
::= { prvtNetworkLoopbackTestObjects 1 }
prvtNetworkLoopbackTestEntry OBJECT-TYPE
SYNTAX PrvtNetworkLoopbackTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the prvtNetworkLoopbackTestTable table"
INDEX { ifIndex, accessListControlListGroup }
::= { prvtNetworkLoopbackTestTable 1 }
PrvtNetworkLoopbackTestEntry ::= SEQUENCE {
prvtNetworkLoopTestDuration INTEGER,
prvtNetworkLoopStartDuration TimeStamp,
prvtNetworkLoopEndDuration TimeStamp,
prvtNetworkLoopRowStatus RowStatus
}
prvtNetworkLoopTestDuration OBJECT-TYPE
SYNTAX INTEGER (0..100000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An integer that identifies the duration in seconds of Loopback test.
For infinite Loopback tests object will have the value 0."
::= {prvtNetworkLoopbackTestEntry 1}
prvtNetworkLoopStartDuration OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Star time of Loopback test.
For infinite Loopback tests object will have the value 0."
::= {prvtNetworkLoopbackTestEntry 2}
prvtNetworkLoopEndDuration OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"End time of Loopback test.
For infinite Loopback tests object will have the value 0."
::= {prvtNetworkLoopbackTestEntry 3}
prvtNetworkLoopRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Network Loopback Test RowStatus.
Both createAndGo(4) and createAndWait(5) are available.
CreateAndGo(4) is used for enable a Loopback test unlimited in time and CreateAndWait(4)
for enable a Loopback Test on a period specified by prvtNetworkLoopTestDuration."
::= {prvtNetworkLoopbackTestEntry 4}
-- ----------------------------------------------------------------------------
-- Notifications
-- ----------------------------------------------------------------------------
prvtNetworkLoopbackTestFinish NOTIFICATION-TYPE
OBJECTS { ifIndex, accessListControlListGroup }
STATUS current
DESCRIPTION
"This notification is sent when a Network Loopback Test is complete."
::= {prvtNetworkLoopbackTestNotifications 1}
-- ----------------------------------------------------------------------------
-- Conformance Information
-- ----------------------------------------------------------------------------
prvtNetworkLoopTestCompliances OBJECT IDENTIFIER ::= {prvtNetworkLoopbackTestConformance 1}
prvtNetworkLoopTestGroups OBJECT IDENTIFIER ::= {prvtNetworkLoopbackTestConformance 2}
-- compliance statements
prvtNetworkLoopTestCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for Network Loopback Tester."
MODULE -- this module
MANDATORY-GROUPS {
prvtNetworkLoopTestGroup,
prvtNetworkLoopTestNotificationsGroup
}
::= {prvtNetworkLoopTestCompliances 1}
prvtNetworkLoopTestGroup OBJECT-GROUP
OBJECTS {prvtNetworkLoopTestDuration,
prvtNetworkLoopStartDuration,
prvtNetworkLoopEndDuration,
prvtNetworkLoopRowStatus
}
STATUS current
DESCRIPTION
"The group of objects regarding Network Looback Tester feature."
::= {prvtNetworkLoopTestGroups 1}
prvtNetworkLoopTestNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS{
prvtNetworkLoopbackTestFinish
}
STATUS current
DESCRIPTION
"The collection of Notifications used to indicate general status information
of Network Looback Tester feature."
::= {prvtNetworkLoopTestGroups 2}
END