mibs/MIBS/telco-systems/binos/PRVT-SWITCH-EFM-OAM-MIB

842 lines
21 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- *********************************************************************
-- *********************************************************************
-- ** Filename: PRVT-SWITCH-EFM-OAM-MIB
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications.
-- BATM Advanced Communications retains all title and
-- ownership in the Specification, including any revisions.
-- BATM Advanced Communications grants all interested parties a non-exclusive
-- license to use and distribute an unmodified copy of this
-- Specification in connection with management of BATM Advanced Communications
-- and Telco Systems<6D>products, and without fee, provided that the following
-- conditions are met:
-- 1. Redistributions of this specification must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
-- or promote products derived from this specification without specific prior written
-- permission.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
PRVT-SWITCH-EFM-OAM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Integer32,
Counter32,
Unsigned32
FROM SNMPv2-SMI
TruthValue,
RowStatus,
DisplayString
FROM SNMPv2-TC
dot3OamAdminState,
dot3OamMode,
dot3OamLoopbackStatus
FROM DOT3-OAM-MIB
ifIndex
FROM IF-MIB
PortList
FROM Q-BRIDGE-MIB
switch
FROM PRVT-SWITCH-MIB;
prvtSwitchEfmOamMIB MODULE-IDENTITY
LAST-UPDATED "201002110000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"This MIB should provide general configuration and
reports of this protocol that are not available in
the standard DOT3-OAM-MIB, such as Enabling and Timers,
as well as the ability to control private
extensions added to the EFM OAM."
-- revision history
REVISION "201002110000Z"
DESCRIPTION
"Change oids for backward compatibility."
REVISION "200912010000Z"
DESCRIPTION
"Added dying-gasp notification"
REVISION "200906010000Z"
DESCRIPTION
"Changed limits for prvtEfmOamPingTable leafs"
REVISION "200904290000Z"
DESCRIPTION
"Changed type for prvtEfmOamEventForwardStatus and
prvtEfmOamEventForwardShutdown to PortList"
REVISION "200903180000Z"
DESCRIPTION
"Fixed range and measurment unit for prvtEfmOamKeepAlive scalar"
REVISION "200903060000Z"
DESCRIPTION
"Removed incorrect scalars
Removed certain leafs in prvtEfmOamPingTable and prvtEfmOamLoopbackTable
Modified prvtEfmOamPingResultTable and prvtEfmOamLoopbackResultTable"
::= { switch 133 }
-- ***********************************************
-- ************ Top level structure of the MIB****
-- ***********************************************
prvtEfmOamNotifications OBJECT IDENTIFIER ::= { prvtSwitchEfmOamMIB 0 }
prvtEfmOamObjects OBJECT IDENTIFIER ::= { prvtSwitchEfmOamMIB 1 }
prvtEfmOamConformance OBJECT IDENTIFIER ::= { prvtSwitchEfmOamMIB 2 }
-- ***********************************************
-- ************* global scalar objects ***********
-- ***********************************************
prvtEfmOamEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/disable the EFM OAM on the device"
::= { prvtEfmOamObjects 1 }
prvtEfmOamMultiPduCount OBJECT-TYPE
SYNTAX Unsigned32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of OAM PDUs that will be sent when
protocol ask to send multiple subsequent
messages."
DEFVAL { 5 }
::= { prvtEfmOamObjects 2 }
prvtEfmOamRemoteEvent OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable sending the local
event notifications to the remote device."
DEFVAL { true }
::= { prvtEfmOamObjects 3 }
prvtEfmOamLocalSysLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Disable/enable sending of Event Notification
OAM PDU to the local Syslog daemon."
DEFVAL { true }
::= { prvtEfmOamObjects 4 }
prvtEfmOamPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority of the sent OAM PDUs.
Please note that value 8 represents no-priority."
DEFVAL { 8 }
::= { prvtEfmOamObjects 5 }
prvtEfmOamKeepAlive OBJECT-TYPE
SYNTAX Unsigned32 (100..15000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Aging interval (in miliseconds)of the last heard
neighbouring device."
DEFVAL { 5000 }
::= { prvtEfmOamObjects 6 }
prvtEfmOamHelloInterval OBJECT-TYPE
SYNTAX Unsigned32 (100..5000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximal interval between a pair of PDUs in milliseconds."
DEFVAL { 1000 }
::= { prvtEfmOamObjects 7 }
prvtEfmOamPktsSent OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent packets."
::= { prvtEfmOamObjects 8 }
prvtEfmOamPktsReceived OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received packets."
::= { prvtEfmOamObjects 9 }
prvtEfmOamHistorySize OBJECT-TYPE
SYNTAX Unsigned32 (1000..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of entries in EFM_OAM history."
DEFVAL { 5000 }
::= { prvtEfmOamObjects 14 }
-- ***********************************************
-- ************* prvtEfmOamTable *****************
-- ***********************************************
prvtEfmOamTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtEfmOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table shall containg an entry per
physical interface, indexed by the corresponding
ifIndex from IF-MIB and each row in the
table shall contain a single column."
::= { prvtEfmOamObjects 10 }
prvtEfmOamEntry OBJECT-TYPE
SYNTAX PrvtEfmOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EFM Entry"
INDEX { ifIndex }
::= { prvtEfmOamTable 1 }
PrvtEfmOamEntry ::= SEQUENCE {
prvtEfmOamEnhanceMode INTEGER,
prvtEfmOamEventReturn Integer32,
prvtEfmOamForceLoopbackLocal TruthValue,
prvtEfmOamForceLoopbackRemote TruthValue,
prvtEfmOamEventForwardStatus PortList,
prvtEfmOamEventForwardShutdown PortList
}
prvtEfmOamEnhanceMode OBJECT-TYPE
SYNTAX INTEGER {
basic ( 1 ),
enhance ( 2 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to be used to enable or disable EFM-OAM
Vendor specific extensions on the
specific interface. Values are :
- basic(1) - no Vendor specific OAM
extensions are used.
- enhance(2) - when the remote device is detected
as Vendor device, enhanced mode is used."
DEFVAL { basic }
::= { prvtEfmOamEntry 1 }
prvtEfmOamEventReturn OBJECT-TYPE
SYNTAX Integer32 (0 | 1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"0 - feature is disabled (default value)
1-10 - feature is enabled. The number
specifies how many handshaking attempts
will be done before shutting down the port."
DEFVAL { 0 }
::= { prvtEfmOamEntry 2 }
prvtEfmOamForceLoopbackLocal OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Used to force permanent loopback configuration
on the local side.
This is used for loopback traffic
analysis for long term (for example,
24 hours length infrastructure testing).
"
DEFVAL { false }
::= { prvtEfmOamEntry 3 }
prvtEfmOamForceLoopbackRemote OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Used to force permanent loopback configuration
on the remote side.
This is used for loopback traffic
analysis for long term (for example,
24 hours length infrastructure testing).
"
DEFVAL { false }
::= { prvtEfmOamEntry 4 }
prvtEfmOamEventForwardStatus OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Forward a Link EventNotification on the specified target
interface. Note that the interface which will
forward the EventNotification must have efm-oam mode enabled.
"
::= { prvtEfmOamEntry 5 }
prvtEfmOamEventForwardShutdown OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Shutdown a specified target interface as a
result of the current interface status change.
"
::= { prvtEfmOamEntry 6 }
-- ***********************************************
-- ************ prvtEfmOamPingTable **************
-- ***********************************************
prvtEfmOamPing OBJECT IDENTIFIER ::= { prvtEfmOamObjects 11 }
prvtEfmOamPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtEfmOamPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table let the EFM-OAM non-intrusive monitoring
on the specific interface by querying a number
of time aFramesTransmittedOK parameter, ping requests,
using the variable retrieval EFM OAM PDU."
::= { prvtEfmOamPing 1 }
prvtEfmOamPingEntry OBJECT-TYPE
SYNTAX PrvtEfmOamPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { ifIndex }
::= { prvtEfmOamPingTable 1 }
PrvtEfmOamPingEntry ::= SEQUENCE {
prvtEfmOamPingEchoNumber Unsigned32,
prvtEfmOamPingDelayTime Unsigned32,
prvtEfmOamPingTimeOut Unsigned32,
prvtEfmOamPingCounterBranch INTEGER,
prvtEfmOamPingCounterLeaf INTEGER,
prvtEfmOamPingRowStatus RowStatus
}
prvtEfmOamPingEchoNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of echo packets to send."
DEFVAL { 5 }
::= { prvtEfmOamPingEntry 1 }
prvtEfmOamPingDelayTime OBJECT-TYPE
SYNTAX Unsigned32 (0..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay in seconds between packets."
DEFVAL { 0 }
::= { prvtEfmOamPingEntry 2 }
prvtEfmOamPingTimeOut OBJECT-TYPE
SYNTAX Unsigned32 (1..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in seconds which the ping
should wait for the response."
DEFVAL { 2 }
::= { prvtEfmOamPingEntry 3 }
prvtEfmOamPingCounterBranch OBJECT-TYPE
SYNTAX INTEGER
{
branch ( 7 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set/get the counter of ping-like operation."
::= { prvtEfmOamPingEntry 4 }
prvtEfmOamPingCounterLeaf OBJECT-TYPE
SYNTAX INTEGER
{
framesTransmittedOK ( 2 ),
framesReceivedOK ( 5 ),
octetsTransmittedOK ( 8 ),
octetsReceivedOK ( 14 ),
multicastFramesReceivedOK ( 21 ),
broadcastFramesReceivedOK ( 22 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set/get the counter of ping-like operation."
::= { prvtEfmOamPingEntry 5 }
prvtEfmOamPingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/delete/edit of the ping test."
::= { prvtEfmOamPingEntry 6 }
-- ***********************************************
-- ******** prvtEfmOamPingResultTable ************
-- ***********************************************
prvtEfmOamPingResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtEfmOamPingResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ping results."
::= { prvtEfmOamPing 2 }
prvtEfmOamPingResultEntry OBJECT-TYPE
SYNTAX PrvtEfmOamPingResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { ifIndex }
::= { prvtEfmOamPingResultTable 1 }
PrvtEfmOamPingResultEntry ::= SEQUENCE {
prvtEfmOamPingResultStatus INTEGER,
prvtEfmOamPingResultSentPackets Counter32,
prvtEfmOamPingResultReceivedPackets Counter32,
prvtEfmOamPingResultRcvRateInteger Unsigned32,
prvtEfmOamPingResultRcvRateFractional Unsigned32,
prvtEfmOamPingResultTimeMin Unsigned32,
prvtEfmOamPingResultTimeMax Unsigned32,
prvtEfmOamPingResultAverageTimeInteger Unsigned32,
prvtEfmOamPingResultAverageTimeFractional Unsigned32,
prvtEfmOamPingResultClear INTEGER
}
prvtEfmOamPingResultStatus OBJECT-TYPE
SYNTAX INTEGER
{
noPing ( 1 ),
running ( 2 ),
terminated ( 3 )
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current ping operation status."
::= { prvtEfmOamPingResultEntry 1 }
prvtEfmOamPingResultSentPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent packets"
::= { prvtEfmOamPingResultEntry 2 }
prvtEfmOamPingResultReceivedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received packets"
::= { prvtEfmOamPingResultEntry 3 }
prvtEfmOamPingResultRcvRateInteger OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ping receive rate - Integer part"
::= { prvtEfmOamPingResultEntry 4 }
prvtEfmOamPingResultRcvRateFractional OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ping receive rate - Fractional part"
::= { prvtEfmOamPingResultEntry 5 }
prvtEfmOamPingResultTimeMin OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ping minimum time."
::= { prvtEfmOamPingResultEntry 6 }
prvtEfmOamPingResultTimeMax OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ping maximum time."
::= { prvtEfmOamPingResultEntry 7 }
prvtEfmOamPingResultAverageTimeInteger OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ping average time - Integer part."
::= { prvtEfmOamPingResultEntry 8 }
prvtEfmOamPingResultAverageTimeFractional OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ping average time - Fractional part."
::= { prvtEfmOamPingResultEntry 9 }
prvtEfmOamPingResultClear OBJECT-TYPE
SYNTAX INTEGER {
none ( 0 ),
clear ( 1 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Deleteper interface entries in prvtEfmOamPingResultTable."
::= { prvtEfmOamPingResultEntry 10 }
-- ***********************************************
-- ************ prvtEfmOamLoopbackTable **********
-- ***********************************************
prvtEfmOamLoopback OBJECT IDENTIFIER ::= { prvtEfmOamObjects 12 }
prvtEfmOamLoopbackTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtEfmOamLoopbackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table should permit to perform EFM-OAM
intrusive monitoring on the specific interface
by setting the remote device into loopback state
and generating test traffic.
It should support:
Storm operation, an operation that sets
remote loopback, stops local data flow to the
remote box and generates a packet burst by CPU.
When the burst is received back it is validated
and statistics are displayed. Burst operation,
an operation that sets remote loopback, stops
local data flow to the remote box and generates
a packet test burst by the hardware (when available).
It means a single packet generated by CPU is
repetitively sent by the hardware. When the
burst is received back it is ignored and only
counters are displayed."
::= { prvtEfmOamLoopback 1 }
prvtEfmOamLoopbackEntry OBJECT-TYPE
SYNTAX PrvtEfmOamLoopbackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { ifIndex }
::= { prvtEfmOamLoopbackTable 1 }
PrvtEfmOamLoopbackEntry ::= SEQUENCE {
prvtEfmOamLoopbackOperation INTEGER,
prvtEfmOamLoopbackDuration Unsigned32,
prvtEfmOamLoopbackCount Unsigned32,
prvtEfmOamLoopbackPacketSize Unsigned32,
prvtEfmOamLoopbackDelay Unsigned32,
prvtEfmOamLoopbackTimeout Unsigned32,
prvtEfmOamLoopbackNoRemote TruthValue,
prvtEfmOamLoopbackRowStatus RowStatus
}
prvtEfmOamLoopbackOperation OBJECT-TYPE
SYNTAX INTEGER {
storm ( 1 ),
burst ( 2 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Represent the operation that the
should be performed on the interface."
::= { prvtEfmOamLoopbackEntry 1 }
prvtEfmOamLoopbackDuration OBJECT-TYPE
SYNTAX Unsigned32 (1..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Represent the amount of time burst test should run in seconds."
DEFVAL { 10 }
::= { prvtEfmOamLoopbackEntry 2 }
prvtEfmOamLoopbackCount OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483646)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Represent the count of packets to send in storm operation."
DEFVAL { 100 }
::= { prvtEfmOamLoopbackEntry 3 }
prvtEfmOamLoopbackPacketSize OBJECT-TYPE
SYNTAX Unsigned32 (64..1512)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Represent the size of the test packet to use."
DEFVAL { 64 }
::= { prvtEfmOamLoopbackEntry 4 }
prvtEfmOamLoopbackDelay OBJECT-TYPE
SYNTAX Unsigned32 (0..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Represent the delay between packets in seconds.
The default value is 0 and represents no delay."
DEFVAL { 0 }
::= { prvtEfmOamLoopbackEntry 5 }
prvtEfmOamLoopbackTimeout OBJECT-TYPE
SYNTAX Unsigned32 (1..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Represent the wait for response in seconds."
DEFVAL { 2 }
::= { prvtEfmOamLoopbackEntry 6 }
prvtEfmOamLoopbackNoRemote OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Add or not remote to loopback."
DEFVAL { false }
::= { prvtEfmOamLoopbackEntry 7 }
prvtEfmOamLoopbackRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
""
::= { prvtEfmOamLoopbackEntry 8 }
-- ***********************************************
-- ******** prvtEfmOamLoopbackResultTable ********
-- ***********************************************
prvtEfmOamLoopbackResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtEfmOamLoopbackResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Loopback results."
::= { prvtEfmOamLoopback 2 }
prvtEfmOamLoopbackResultEntry OBJECT-TYPE
SYNTAX PrvtEfmOamLoopbackResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { ifIndex }
::= { prvtEfmOamLoopbackResultTable 1 }
PrvtEfmOamLoopbackResultEntry ::= SEQUENCE {
prvtEfmOamLoopbackResultStatus INTEGER,
prvtEfmOamLoopbackResultFlood INTEGER,
prvtEfmOamLoopbackResultSentPackets Counter32,
prvtEfmOamLoopbackResultReceivedPackets Counter32,
prvtEfmOamLoopbackResultClear INTEGER
}
prvtEfmOamLoopbackResultStatus OBJECT-TYPE
SYNTAX INTEGER
{
noLoopback ( 1 ),
startCmdSent ( 2 ),
startFail ( 3 ),
dataStarted ( 4 ),
stopCmdSent ( 5 ),
terminated ( 6 ),
remoteFailure ( 7 )
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loopback result status"
::= { prvtEfmOamLoopbackResultEntry 1 }
prvtEfmOamLoopbackResultFlood OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Flood value"
::= { prvtEfmOamLoopbackResultEntry 2 }
prvtEfmOamLoopbackResultSentPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent packets"
::= { prvtEfmOamLoopbackResultEntry 3 }
prvtEfmOamLoopbackResultReceivedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received packets"
::= { prvtEfmOamLoopbackResultEntry 4 }
prvtEfmOamLoopbackResultClear OBJECT-TYPE
SYNTAX INTEGER {
none ( 0 ),
clear ( 1 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Delete per interface entries in prvtEfmOamLoopbackResultTable."
::= { prvtEfmOamLoopbackResultEntry 5 }
-- ***********************************************
-- ************ prvtEfmOamPeerTable **************
-- ***********************************************
prvtEfmOamPeerTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtEfmOamPeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table holds the peer extended information
available only when local interface is set in
enhanced mode (see prvtOamEnhanceMode) and the
remote is detected as enhanced-mode device. This table
shall containg an entry per physical interface,
indexed by the corresponding ifIndex from IF-MIB."
::= { prvtEfmOamObjects 13 }
prvtEfmOamPeerEntry OBJECT-TYPE
SYNTAX PrvtEfmOamPeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { ifIndex }
::= { prvtEfmOamPeerTable 1 }
PrvtEfmOamPeerEntry ::= SEQUENCE {
prvtEfmOamPeerPort DisplayString,
prvtEfmOamPeerName DisplayString
}
prvtEfmOamPeerPort OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Holds the peer port name as string
as it is sent by the peer (eg: 1/2/1)."
::= { prvtEfmOamPeerEntry 1 }
prvtEfmOamPeerName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Holds the peer hostname s string
as it is sent by the peer."
::= { prvtEfmOamPeerEntry 2 }
-- ***********************************************
-- **************** Notification *****************
-- ***********************************************
prvtOamLoopBackState NOTIFICATION-TYPE
OBJECTS {
ifIndex,
dot3OamAdminState,
dot3OamMode,
dot3OamLoopbackStatus
}
STATUS current
DESCRIPTION
"This trap should be sent whenever the loopback
state has been change from Remote, when dot3OamMode
is passive or dot3OamAdminState is disable the
interface cannot be on remoteLoopback state
and should send this trap."
::= { prvtEfmOamNotifications 1 }
prvtOamDyingGasp NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The notification alarms for a failure due to loss of local power
('Dying Gasp')"
::= { prvtEfmOamNotifications 2 }