mibs/MIBS/telco-systems/binox/PRVT-CFM-MIB

3377 lines
123 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-CFM-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-CFM-MIB DEFINITIONS ::= BEGIN
IMPORTS
InterfaceIndex
FROM IF-MIB
switch
FROM PRVT-SWITCH-MIB
Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE,
OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
MacAddress, RowStatus, TAddress, TDomain, TEXTUAL-CONVENTION,
TimeStamp, TruthValue
FROM SNMPv2-TC;
prvtCfmMIB MODULE-IDENTITY
LAST-UPDATED "201404170000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"Prvt extension of Connectivity Fault Management module for managing IEEE 802.1ag"
REVISION "201404170000Z"
DESCRIPTION
"Increased the number of profiles to 64"
REVISION "201104110000Z"
DESCRIPTION
"Initial"
::= { switch 131 }
LldpChassisIdSubtype ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This TC describes the source of a chassis identifier.
The enumeration 'chassisComponent(1)' represents a chassis
identifier based on the value of entPhysicalAlias object
(defined in IETF RFC 2737) for a chassis component (i.e.,
an entPhysicalClass value of 'chassis(3)').
The enumeration 'interfaceAlias(2)' represents a chassis
identifier based on the value of ifAlias object (defined in
IETF RFC 2863) for an interface on the containing chassis.
The enumeration 'portComponent(3)' represents a chassis
identifier based on the value of entPhysicalAlias object
(defined in IETF RFC 2737) for a port or backplane
component (i.e., entPhysicalClass value of 'port(10)' or
'backplane(4)'), within the containing chassis.
The enumeration 'macAddress(4)' represents a chassis
identifier based on the value of a unicast source address
(encoded in network byte order and IEEE 802.3 canonical bit
order), of a port on the containing chassis as defined in
IEEE Std 802-2001.
The enumeration 'networkAddress(5)' represents a chassis
identifier based on a network address, associated with
a particular chassis. The encoded address is actually
composed of two fields. The first field is a single octet,
representing the IANA AddressFamilyNumbers value for the
specific address type, and the second field is the network
address value.
The enumeration 'interfaceName(6)' represents a chassis
identifier based on the value of ifName object (defined in
IETF RFC 2863) for an interface on the containing chassis.
The enumeration 'local(7)' represents a chassis identifier
based on a locally defined value."
SYNTAX INTEGER { notSet(0), chassisComponent(1),
interfaceAlias(2), portComponent(3), macAddress(4),
networkAddress(5), interfaceName(6), local(7) }
LldpChassisId ::= TEXTUAL-CONVENTION
DISPLAY-HINT "250a"
STATUS current
DESCRIPTION
"This TC describes the format of a chassis identifier string.
Objects of this type are always used with an associated
LldpChassisIdSubtype object, which identifies the format of
the particular LldpChassisId object instance.
If the associated LldpChassisIdSubtype object has a value of
'chassisComponent(1)', then the octet string identifies
a particular instance of the entPhysicalAlias object
(defined in IETF RFC 2737) for a chassis component (i.e.,
an entPhysicalClass value of 'chassis(3)').
If the associated LldpChassisIdSubtype object has a value
of 'interfaceAlias(2)', then the octet string identifies
a particular instance of the ifAlias object (defined in
IETF RFC 2863) for an interface on the containing chassis.
If the particular ifAlias object does not contain any values,
another chassis identifier type should be used.
If the associated LldpChassisIdSubtype object has a value
of 'portComponent(3)', then the octet string identifies a
particular instance of the entPhysicalAlias object (defined
in IETF RFC 2737) for a port or backplane component within
the containing chassis.
If the associated LldpChassisIdSubtype object has a value of
'macAddress(4)', then this string identifies a particular
unicast source address (encoded in network byte order and
IEEE 802.3 canonical bit order), of a port on the containing
chassis as defined in IEEE Std 802-2001.
If the associated LldpChassisIdSubtype object has a value of
'networkAddress(5)', then this string identifies a particular
network address, encoded in network byte order, associated
with one or more ports on the containing chassis. The first
octet contains the IANA Address Family Numbers enumeration
value for the specific address type, and octets 2 through
N contain the network address value in network byte order.
If the associated LldpChassisIdSubtype object has a value
of 'interfaceName(6)', then the octet string identifies
a particular instance of the ifName object (defined in
IETF RFC 2863) for an interface on the containing chassis.
If the particular ifName object does not contain any values,
another chassis identifier type should be used.
If the associated LldpChassisIdSubtype object has a value of
'local(7)', then this string identifies a locally assigned
Chassis ID."
SYNTAX OCTET STRING
LldpPortIdSubtype ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This TC describes the source of a particular type of port
identifier used in the LLDP MIB.
The enumeration 'interfaceAlias(1)' represents a port
identifier based on the ifAlias MIB object, defined in IETF
RFC 2863.
The enumeration 'portComponent(2)' represents a port
identifier based on the value of entPhysicalAlias (defined in
IETF RFC 2737) for a port component (i.e., entPhysicalClass
value of 'port(10)'), within the containing chassis.
The enumeration 'macAddress(3)' represents a port identifier
based on a unicast source address (encoded in network
byte order and IEEE 802.3 canonical bit order), which has
been detected by the agent and associated with a particular
port (IEEE Std 802-2001).
The enumeration 'networkAddress(4)' represents a port
identifier based on a network address, detected by the agent
and associated with a particular port.
The enumeration 'interfaceName(5)' represents a port
identifier based on the ifName MIB object, defined in IETF
RFC 2863.
The enumeration 'agentCircuitId(6)' represents a port
identifier based on the agent-local identifier of the circuit
(defined in RFC 3046), detected by the agent and associated
with a particular port.
The enumeration 'local(7)' represents a port identifier
based on a value locally assigned."
SYNTAX INTEGER { notSet(0), interfaceAlias(1), portComponent(2),
macAddress(3), networkAddress(4), interfaceName(5),
agentCircuitId(6), local(7) }
LldpPortId ::= TEXTUAL-CONVENTION
DISPLAY-HINT "250a"
STATUS current
DESCRIPTION
"This TC describes the format of a port identifier string.
Objects of this type are always used with an associated
LldpPortIdSubtype object, which identifies the format of the
particular LldpPortId object instance.
If the associated LldpPortIdSubtype object has a value of
'interfaceAlias(1)', then the octet string identifies a
particular instance of the ifAlias object (defined in IETF
RFC 2863). If the particular ifAlias object does not contain
any values, another port identifier type should be used.
If the associated LldpPortIdSubtype object has a value of
'portComponent(2)', then the octet string identifies a
particular instance of the entPhysicalAlias object (defined
in IETF RFC 2737) for a port or backplane component.
If the associated LldpPortIdSubtype object has a value of
'macAddress(3)', then this string identifies a particular
unicast source address (encoded in network byte order
and IEEE 802.3 canonical bit order) associated with the port
(IEEE Std 802-2001).
If the associated LldpPortIdSubtype object has a value of
'networkAddress(4)', then this string identifies a network
address associated with the port. The first octet contains
the IANA AddressFamilyNumbers enumeration value for the
specific address type, and octets 2 through N contain the
networkAddress address value in network byte order.
If the associated LldpPortIdSubtype object has a value of
'interfaceName(5)', then the octet string identifies a
particular instance of the ifName object (defined in IETF
RFC 2863). If the particular ifName object does not contain
any values, another port identifier type should be used.
If the associated LldpPortIdSubtype object has a value of
'agentCircuitId(6)', then this string identifies a agent-local
identifier of the circuit (defined in RFC 3046).
If the associated LldpPortIdSubtype object has a value of
'local(7)', then this string identifies a locally
assigned port ID."
SYNTAX OCTET STRING
PrvtCfmMaintAssocName ::= TEXTUAL-CONVENTION
DISPLAY-HINT "45a"
STATUS current
DESCRIPTION
"Denotes a generic Maintenance Association Name. It is the
part of the Maintenance Association Identifier which is
unique within the Maintenance Domain Name and is appended
to the Maintenance Domain Name to form the Maintenance
Association Identifier (MAID).
A PrvtCfmMaintAssocName value is always interpreted within
the context of a PrvtCfmMaintAssocNameType value. Every
usage of the PrvtCfmMaintAssocName textual convention is
required to specify the PrvtCfmMaintAssocNameType object
that provides the context. It is suggested that the
PrvtCfmMaintAssocNameType object be logically registered
before the object(s) that use the PrvtCfmMaintAssocName
textual convention, if they appear in the same logical row.
The value of a PrvtCfmMaintAssocName object must
always be consistent with the value of the associated
PrvtCfmMaintAssocNameType object. Attempts to set
an PrvtCfmMaintAssocName object to a value inconsistent
with the associated PrvtCfmMaintAssocNameType must fail
with an inconsistentValue error.
When this textual convention is used as the syntax of an
index object, there may be issues with the limit of 128
sub-identifiers specified in SMIv2, IETF STD 58. In this
case, the object definition MUST include a 'SIZE' clause
to limit the number of potential instance sub-identifiers;
otherwise the applicable constraints MUST be stated in
the appropriate conceptual row DESCRIPTION clauses, or
in the surrounding documentation if there is no single
DESCRIPTION clause that is appropriate."
REFERENCE
"802.1ag clauses 21.6.5.4, 21.6.5.5, 21.6.5.6"
SYNTAX OCTET STRING (SIZE(1..22))
PrvtCfmMaintAssocNameOrNone ::= TEXTUAL-CONVENTION
DISPLAY-HINT "22a"
STATUS current
DESCRIPTION
"Same as PrvtCfmMaintAssocName except that zero
length string represents no association name. "
SYNTAX OCTET STRING (SIZE(0..22))
PrvtCfmMhfCreation ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates if the Management Entity can create MHFs.
The valid values are:
defMHFnone(1) No MHFs can be created for this VID.
defMHFdefault(2) MHFs can be created on this VID on any
Bridge port through which this VID can
pass.
defMHFexplicit(3) MHFs can be created for this VID only on
Bridge ports through which this VID can
pass, and only if a MEP is created at some
lower MD Level.
defMHFdefer(4) The creation of MHFs is determined by the
corresponding Maintenance Domain variable
(prvtCfmMaMhfCreation)."
REFERENCE
"802.1ag clause 12.14.5.1.3:c and 22.2.3"
SYNTAX INTEGER { defMHFnone(1), defMHFdefault(2),
defMHFexplicit(3), defMHFdefer(4) }
PrvtCfmMhfCreationDef ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates if the Management Entity can create MHFs.
The valid values are:
defMHFnone(1) No MHFs can be created for this VID.
defMHFdefault(2) MHFs can be created on this VID on any
Bridge port through which this VID can
pass.
defMHFexplicit(3) MHFs can be created for this VID only on
Bridge ports through which this VID can
pass, and only if a MEP is created at some
lower MD Level.
defMHFdefer(4) The creation of MHFs is determined by the
corresponding Maintenance Domain variable
(prvtCfmMaMhfCreation)."
REFERENCE
"802.1ag clause 12.14.5.1.3:c and 22.2.3"
SYNTAX INTEGER { defMHFnone(1), defMHFdefault(2),
defMHFexplicit(3) }
PrvtCfmIdPermission ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates what, if anything, is to be included in the Sender
ID TLV transmitted in CCMs, LBMs, LTMs, and LTRs. The valid
values are:
sendIdNone(1) The Sender ID TLV is not to be sent.
sendIdChassis(2) The Chassis ID Length, Chassis ID
Subtype, and Chassis ID fields of the
Sender ID TLV are to be sent.
sendIdManage(3) The Management Address Length and
Management Address of the Sender ID TLV
are to be sent.
sendIdChassisManage(4) The Chassis ID Length, Chassis ID
Subtype, Chassis ID, Management Address
Length and Management Address fields are
all to be sent.
sendIdDefer(5) The contents of the Sender ID TLV are
determined by the corresponding
Maintenance Domain variable
(prvtCfmMaIdPermission)."
REFERENCE
"802.1ag clause 12.14.6.1.3:d and 21.5.3"
SYNTAX INTEGER { sendIdNone(1), sendIdChassis(2),
sendIdManage(3), sendIdChassisManage(4),
sendIdDefer(5) }
PrvtCfmIdPermissionDef ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates what, if anything, is to be included in the Sender
ID TLV transmitted in CCMs, LBMs, LTMs, and LTRs. The valid
values are:
sendIdNone(1) The Sender ID TLV is not to be sent.
sendIdChassis(2) The Chassis ID Length, Chassis ID
Subtype, and Chassis ID fields of the
Sender ID TLV are to be sent.
sendIdManage(3) The Management Address Length and
Management Address of the Sender ID TLV
are to be sent.
sendIdChassisManage(4) The Chassis ID Length, Chassis ID
Subtype, Chassis ID, Management Address
Length and Management Address fields are
all to be sent.
sendIdDefer(5) The contents of the Sender ID TLV are
determined by the corresponding
Maintenance Domain variable
(prvtCfmMaIdPermission)."
REFERENCE
"802.1ag clause 12.14.6.1.3:d and 21.5.3"
SYNTAX INTEGER { sendIdNone(1), sendIdChassis(2),
sendIdManage(3), sendIdChassisManage(4) }
PrvtCfmMaintAssocNameType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A value that represents a type (and thereby the format)
of a PrvtCfmMaintAssocName. The value can be one of
the following:
ieeeReserved(0) Reserved for definition by IEEE 802.1
recommend to not use zero unless
absolutely needed.
primaryVid(1) Primary VLAN ID.
12 bits represented in a 2-octet integer:
- 4 least significant bits of the first
byte contains the 4 most significant
bits of the 12 bits primary VID
- second byte contains the 8 least
significant bits of the primary VID
0 1 2 3 4 5 6 7 8
+-+-+-+-+-+-+-+-+
|0 0 0 0| (MSB) |
+-+-+-+-+-+-+-+-+
| VID LSB |
+-+-+-+-+-+-+-+-+
charString(2) RFC2579 DisplayString, except that the
character codes 0-31 (decimal) are not
used. (1..45) octets
unsignedInt16 (3) 2-octet integer/big endian
rfc2865VpnId(4) RFC 2685 VPN ID
3 octet VPN authority Organizationally
Unique Identifier followed by 4 octet VPN
index identifying VPN according to the OUI:
0 1 2 3 4 5 6 7 8
+-+-+-+-+-+-+-+-+
| VPN OUI (MSB) |
+-+-+-+-+-+-+-+-+
| VPN OUI |
+-+-+-+-+-+-+-+-+
| VPN OUI (LSB) |
+-+-+-+-+-+-+-+-+
|VPN Index (MSB)|
+-+-+-+-+-+-+-+-+
| VPN Index |
+-+-+-+-+-+-+-+-+
| VPN Index |
+-+-+-+-+-+-+-+-+
|VPN Index (LSB)|
+-+-+-+-+-+-+-+-+
ieeeReserved(xx) Reserved for definition by IEEE 802.1
xx values can be [5..31] and [64..255]
ituReserved(xx) Reserved for definition by ITU-T Y.1731
xx values range from [32..63]
To support future extensions, the PrvtCfmMaintAssocNameType
textual convention SHOULD NOT be sub-typed in object type
definitions. It MAY be sub-typed in compliance statements in
order to require only a subset of these address types for a
compliant implementation.
Implementations must ensure that PrvtCfmMaintAssocNameType
objects and any dependent objects (e.g.,
PrvtCfmMaintAssocName objects) are consistent. An
inconsistentValue error must be generated if an attempt to
change an PrvtCfmMaintAssocNameType object would, for
example, lead to an undefined PrvtCfmMaintAssocName value.
In particular,
PrvtCfmMaintAssocNameType/PrvtCfmMaintAssocName pairs
must be changed together if the nameType changes.
The Maintenance Domain name and Maintenance Association name,
when put together into the CCM PDU, MUST total 48 octets or
less. If the PrvtCfmMaintDomainNameType object contains
none(1), then the PrvtCfmMaintAssocName object MUST be
45 octets or less in length. Otherwise, the length of
the PrvtCfmMaintDomainName object plus the length of the
PrvtCfmMaintAssocName object, added together, MUST total
less than or equal to 44 octets."
REFERENCE
"802.1ag clause 21.6.5.4, Table 21-20"
SYNTAX INTEGER { primaryVid(1), charString(2), icc(32) }
PrvtCfmCcmInterval ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the interval at which CCMs are sent by a MEP.
The possible values are:
-- intervalInvalid(0) No CCMs are sent (disabled).
interval300Hz(1) CCMs are sent every 3 1/3 milliseconds
(300Hz).
interval10ms(2) CCMs are sent every 10 milliseconds.
interval100ms(3) CCMs are sent every 100 milliseconds.
interval1s(4) CCMs are sent every 1 second.
interval10s(5) CCMs are sent every 10 seconds.
interval1min(6) CCMs are sent every minute.
interval10min(7) CCMs are sent every 10 minutes.
Note: enumerations start at zero to match the 'CCM Interval
field' protocol field."
REFERENCE
"802.1ag clauses 12.14.6.1.3:e, 20.8.1 and 21.6.1.3"
SYNTAX INTEGER { interval300Hz(1), interval10ms(2),
interval100ms(3), interval1s(4), interval10s(5),
interval1min(6), interval10min(7) }
PrvtCfmIndexIntegerNextFree ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"An integer which may be used as a new Index in a table.
The special value of 0 indicates that no more new entries can
be created in the relevant table.
When a MIB is used for configuration, an object with this
SYNTAX always contains a legal value (if non-zero) for an
index that is not currently used in the relevant table. The
Command Generator (Network Management Application) reads this
variable and uses the (non-zero) value read when creating a
new row with an SNMP SET. When the SET is performed, the
Command Responder (agent) must determine whether the value is
indeed still unused; Two Network Management Applications may
attempt to create a row (configuration entry) simultaneously
and use the same value. If it is currently unused, the SET
succeeds and the Command Responder (agent) changes the value
of this object, according to an implementation-specific
algorithm. If the value is in use, however, the SET fails.
The Network Management Application must then re-read this
variable to obtain a new usable value.
An OBJECT-TYPE definition using this SYNTAX MUST specify the
relevant table for which the object is providing this
functionality."
SYNTAX Unsigned32
PrvtCfmMaintDomainNameType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A value that represents a type (and thereby the format)
of a PrvtCfmMaintDomainName. The value can be one of
the following:
ieeeReserved(0) Reserved for definition by IEEE 802.1
recommend to not use zero unless
absolutely needed.
none(1) No format specified, usually because
there is not (yet) a Maintenance
Domain Name. In this case, a zero
length OCTET STRING for the Domain
Name field is acceptable.
dnsLikeName(2) Domain Name like string, globally unique
text string derived from a DNS name.
macAddrAndUint(3) MAC address + 2-octet (unsigned) integer.
charString(4) RFC2579 DisplayString, except that the
character codes 0-31 (decimal) are not
used.
ieeeReserved(xx) Reserved for definition by IEEE 802.1
xx values can be [5..31] and [64..255]
ituReserved(xx) Reserved for definition by ITU-T Y.1731
xx values range from [32..63]
To support future extensions, the PrvtCfmMaintDomainNameType
textual convention SHOULD NOT be sub-typed in object type
definitions. It MAY be sub-typed in compliance statements in
order to require only a subset of these address types for a
compliant implementation.
Implementations must ensure that PrvtCfmMaintDomainNameType
objects and any dependent objects (e.g.,
PrvtCfmMaintDomainName objects) are consistent. An
inconsistentValue error must be generated if an attempt to
change an PrvtCfmMaintDomainNameType object would, for
example, lead to an undefined PrvtCfmMaintDomainName value.
In particular,
PrvtCfmMaintDomainNameType/PrvtCfmMaintDomainName pairs
must be changed together if the nameType changes."
REFERENCE
"802.1ag clause 21.6.5, Table 21-19"
SYNTAX INTEGER { none(1), charString(4) }
PrvtCfmMaintDomainName ::= TEXTUAL-CONVENTION
DISPLAY-HINT "43a"
STATUS current
DESCRIPTION
"Denotes a generic Maintenance Domain Name.
A PrvtCfmMaintDomainName value is always interpreted within
the context of a PrvtCfmMaintDomainNameType value. Every
usage of the PrvtCfmMaintDomainName textual convention is
required to specify the PrvtCfmMaintDomainNameType object
that provides the context. It is suggested that the
PrvtCfmMaintDomainNameType object be logically registered
before the object(s) that use the PrvtCfmMaintDomainName
textual convention, if they appear in the same logical row.
The value of a PrvtCfmMaintDomainName object must always
be consistent with the value of the associated
PrvtCfmMaintDomainNameType object. Attempts to set
an PrvtCfmMaintDomainName object to a value inconsistent
with the associated PrvtCfmMaintDomainNameType must fail
with an inconsistentValue error.
When this textual convention is used as the syntax of an
index object, there may be issues with the limit of 128
sub-identifiers specified in SMIv2, IETF STD 58. In this
case, the object definition MUST include a 'SIZE' clause
to limit the number of potential instance sub-identifiers;
otherwise the applicable constraints MUST be stated in
the appropriate conceptual row DESCRIPTION clauses, or
in the surrounding documentation if there is no single
DESCRIPTION clause that is appropriate.
A value of none(1) in the associated
PrvtCfmMaintDomainNameType object means that no Maintenance
Domain name is present, and the contents of the
PrvtCfmMaintDomainName object are meaningless.
See the DESCRIPTION of the PrvtCfmMaintAssocNameType
TEXTUAL-CONVENTION for a discussion of the length limits on
the Maintenance Domain name and Maintenance Association name."
REFERENCE
"802.1ag clause 21.6.5"
SYNTAX OCTET STRING (SIZE(1..22))
PrvtCfmMaintDomainNameOrNone ::= TEXTUAL-CONVENTION
DISPLAY-HINT "22a"
STATUS current
DESCRIPTION
"Same as PrvtCfmMaintDomainName except that zero
length string represents no domain name."
SYNTAX OCTET STRING (SIZE(0..22))
PrvtCfmMDLevelTC ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Integer identifying the Maintenance Domain Level (MD Level).
Higher numbers correspond to higher Maintenance Domains,
those with the greatest physical reach, with the highest
values for customers' CFM PDUs. Lower numbers correspond
to lower Maintenance Domains, those with more limited
physical reach, with the lowest values for CFM PDUs
protecting single bridges or physical links."
REFERENCE
"802.1ag clauses 18.3, 21.4.1"
SYNTAX Integer32 (0..7)
PrvtCfmMpDirection ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the direction in which the Maintenance
association (MEP or MIP) faces on the bridge port:
down(1) Sends Continuity Check Messages away from the
MAC Relay Entity.
up(2) Sends Continuity Check Messages towards the
MAC Relay Entity."
REFERENCE
"802.1ag clauses 12.14.6.3.2:c"
SYNTAX INTEGER { down(1), up(2) }
PrvtCfmMepIdOrZero ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Maintenance association End Point Identifier (MEPID): A small
integer, unique over a given Maintenance Association,
identifying a specific MEP.
The special value 0 is allowed to indicate special cases, for
example that no MEPID is configured.
Whenever an object is defined with this SYNTAX, then the
DESCRIPTION clause of such an object MUST specify what the
special value of 0 means."
REFERENCE
"802.1ag clause 19.2.1"
SYNTAX Unsigned32 (0..8191)
PrvtCfmMepId ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Maintenance association End Point Identifier (MEPID): A small
integer, unique over a given Maintenance Association,
identifying a specific MEP."
REFERENCE
"802.1ag clauses 3.19 and 19.2.1"
SYNTAX Unsigned32 (1..8191)
PrvtCfmFngState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the diferent states of the MEP Fault Notification
Generator State Machine.
fngReset(1) No defect has been present since the
prvtCfmMepFngResetTime timer
expired, or since the state machine
was last reset.
fngDefect(2) A defect is present, but not for a
long enough time to be reported
(prvtCfmMepFngAlarmTime).
fngReportDefect(3) A momentary state during which the
defect is reported by sending a
prvtCfmFaultAlarm notification,
if that action is enabled.
fngDefectReported(4) A defect is present, and some defect
has been reported.
fngDefectClearing(5) No defect is present, but the
prvtCfmMepFngResetTime timer has
not yet expired."
REFERENCE
"802.1ag clause 12.14.7.1.3:f and 20.35"
SYNTAX INTEGER { fngReset(1), fngDefect(2), fngReportDefect(3),
fngDefectReported(4), fngDefectClearing(5) }
PrvtCfmLowestAlarmPri ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An integer value specifying the lowest priority defect
that is allowed to generate a Fault Alarm (20.9.5), either:
allDef(1) DefRDICCM, DefMACstatus, DefRemoteCCM,
DefErrorCCM, and DefXconCCM;
macRemErrXcon(2) Only DefMACstatus, DefRemoteCCM,
DefErrorCCM, and DefXconCCM (default);
remErrXcon(3) Only DefRemoteCCM, DefErrorCCM,
and DefXconCCM;
errXcon(4) Only DefErrorCCM and DefXconCCM;
xcon(5) Only DefXconCCM; or
noXcon(6) No defects DefXcon or lower are to be
reported;"
REFERENCE
"802.1ag clause 12.14.7.1.3:k and 20.9.5"
SYNTAX INTEGER { allDef(1), macRemErrXcon(2), remErrXcon(3),
errXcon(4), xcon(5), noXcon(6) }
PrvtCfmHighestDefectPri ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An enumerated value, equal to the contents of the variable
highestDefect (20.33.9 and Table 20-1), indicating the
highest-priority defect that has been present since the MEP
Fault Notification Generator State Machine was last in the
FNG_RESET state, either:
none(0) no defects since FNG_RESET
defRDICCM(1) DefRDICCM
defMACstatus(2) DefMACstatus
defRemoteCCM(3) DefRemoteCCM
defErrorCCM(4) DefErrorCCM
defXconCCM(5) DefXconCCM
The value 0 is used for no defects so that additional higher
priority values can be added, if needed, at a later time, and
so that these values correspond with those in
PrvtCfmLowestAlarmPri."
REFERENCE
"802.1ag clause 20.1.2, 12.14.7.7.2:c and 20.33.9"
SYNTAX INTEGER { none(0), defRDICCM(1), defMACstatus(2),
defRemoteCCM(3), defErrorCCM(4), defXconCCM(5) }
PrvtCfmRelayActionFieldValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Possible values the Relay action field can take."
REFERENCE
"802.1ag clauses 12.14.7.5.3:g, 20.36.2.5, 21.9.5, and
Table 21-27"
SYNTAX INTEGER { rlyHit(1), rlyFdb(2), rlyMpdb(3) }
PrvtCfmIngressActionFieldValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Possible values returned in the ingress action field."
REFERENCE
"802.1ag clauses 12.14.7.5.3:g, 20.36.2.6, 21.9.8.1, and
Table 21-30"
SYNTAX INTEGER { ingOk(1), ingDown(2), ingBlocked(3), ingVid(4) }
PrvtCfmEgressActionFieldValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Possible values returned in the egress action field"
REFERENCE
"802.1ag clauses 12.14.7.5.3:o, 20.36.2.10, 21.9.9.1, and
Table 21-32"
SYNTAX INTEGER { notSet(0), egrOK(1), egrDown(2), egrBlocked(3),
egrVid(4) }
PrvtCfmRemoteMepState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Operational state of the remote MEP state machine. This
state machine monitors the reception of valid CCMs from a
remote MEP with a specific MEPID. It uses a timer that
expires in 3.5 times the length of time indicated by the
PrvtCfmMaCcmInterval object.
rMepIdle(1) Momentary state during reset.
rMepStart(2) The timer has not expired since the
state machine was reset, and no valid
CCM has yet been received.
rMepFailed(3) The timer has expired, both since the
state machine was reset, and since a
valid CCM was received.
rMepOk(4) The timer has not expired since a
valid CCM was received."
REFERENCE
"802.1ag clauses 12.14.7.6.3:b, 20.22"
SYNTAX INTEGER { rMepIdle(1), rMepStart(2), rMepFailed(3),
rMepOk(4) }
PrvtCfmPortStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An enumerated value from he Port Status TLV from the last CCM
received from the last MEP. It indicates the ability of the
Bridge Port on which the transmitting MEP resides to pass
ordinary data, regardless of the status of the MAC
(Table 21-10).
psNoPortStateTLV(0) Indicates either that no CCM has been
received or that no port status TLV was
present in the last CCM received.
psBlocked(1) Ordinary data cannot pass freely through
the port on which the remote MEP resides.
Value of enableRmepDefect is equal to
false.
psUp(2): Ordinary data can pass freely through
the port on which the remote MEP resides.
Value of enableRmepDefect is equal to
true.
NOTE: A 0 value is used for psNoPortStateTLV, so that
additional code points can be added in a manner
consistent with the PrvtCfmInterfaceStatus textual
convention."
REFERENCE
"802.1ag clause 12.14.7.6.3:f, 20.19.3 and 21.5.4"
SYNTAX INTEGER { psNoPortStateTLV(0), psBlocked(1), psUp(2) }
PrvtCfmInterfaceStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An enumerated value from the Interface Status TLV from the
last CCM received from the last MEP. It indicates the status
of the Interface within which the MEP transmitting the CCM
is configured, or the next lower Interface in the Interface
Stack, if the MEP is not configured within an Interface.
isNoInterfaceStatusTLV(0) Indicates either that no CCM has been
received or that no interface status TLV
was present in the last CCM received.
isUp(1) The interface is ready to pass packets.
isDown(2) The interface cannot pass packets
isTesting(3) The interface is in some test mode.
isUnknown(4) The interface status cannot be determined
for some reason.
isDormant(5) The interface is not in a state to pass
packets but is in a pending state, waiting
for some external event.
isNotPresent(6) Some component of the interface is missing
isLowerLayerDown(7) The interface is down due to state of the
lower layer interfaces
NOTE: A 0 value is used for isNoInterfaceStatusTLV, so that
these code points can be kept consistent with new code
points added to ifOperStatus in the IF-MIB."
REFERENCE
"802.1ag clause 12.14.7.6.3:g, 20.19.4 and 21.5.5"
SYNTAX INTEGER { isNoInterfaceStatusTLV(0), isUp(1), isDown(2),
isTesting(3), isUnknown(4), isDormant(5),
isNotPresent(6), isLowerLayerDown(7) }
prvtCfmMIBNotifications OBJECT IDENTIFIER
::= { prvtCfmMIB 0 }
prvtCfmMIBObjects OBJECT IDENTIFIER
::= { prvtCfmMIB 1 }
prvtCfmUpdateInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time between monitoring parameters update (in seconds).
A value of 0 suspends the monitoring task and a
value different from 0 resumes it. Default is 20 seconds."
::= { prvtCfmMIBObjects 1 }
prvtCfmShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set to 'true' to disable CFM, or to 'false', to enable."
::= { prvtCfmMIBObjects 2 }
prvtCfmStack OBJECT IDENTIFIER
::= { prvtCfmMIBObjects 3 }
prvtCfmStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There is one CFM Stack table per bridge. It permits
the retrieval of information about the Maintenance Points
configured on any given interface."
REFERENCE
"802.1ag clauses 12.14.2"
::= { prvtCfmStack 1 }
prvtCfmStackEntry OBJECT-TYPE
SYNTAX PrvtCfmStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Stack table entry"
INDEX { prvtCfmStackInterfaceIndex,
prvtCfmStackServiceIdOrNone, prvtCfmStackMdLevel,
prvtCfmStackDirection }
::= { prvtCfmStackTable 1 }
PrvtCfmStackEntry ::= SEQUENCE {
prvtCfmStackInterfaceIndex InterfaceIndex,
prvtCfmStackServiceIdOrNone Unsigned32,
prvtCfmStackMdLevel PrvtCfmMDLevelTC,
prvtCfmStackDirection PrvtCfmMpDirection,
prvtCfmStackMdName PrvtCfmMaintDomainNameOrNone,
prvtCfmStackMaName PrvtCfmMaintAssocNameOrNone,
prvtCfmStackMepId Unsigned32,
prvtCfmStackMacAddress MacAddress
}
prvtCfmStackInterfaceIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Bridge Port or aggregated port
on which MEPs or MHFs might be configured.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this variable, and rearrange the
prvtCfmStackTable, so that it indexes the entry in the
interface table with the same value of ifAlias that it
indexed before the system restart. If no such entry exists,
then the system SHALL delete all entries in the
prvtCfmStackTable with the interface index."
REFERENCE
"802.1ag clause 12.14.2.1.2:a"
::= { prvtCfmStackEntry 1 }
prvtCfmStackServiceIdOrNone OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"VLAN ID to which the MP is attached, or 0, if none."
REFERENCE
"802.1ag clause 12.14.2.1.2:d"
::= { prvtCfmStackEntry 2 }
prvtCfmStackMdLevel OBJECT-TYPE
SYNTAX PrvtCfmMDLevelTC
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MD Level of the Maintenance Point."
REFERENCE
"802.1ag clause 12.14.2.1.2:b"
::= { prvtCfmStackEntry 3 }
prvtCfmStackDirection OBJECT-TYPE
SYNTAX PrvtCfmMpDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Direction in which the MP faces on the Bridge Port"
REFERENCE
"802.1ag clause 12.14.2.1.2:c"
::= { prvtCfmStackEntry 4 }
prvtCfmStackMdName OBJECT-TYPE
SYNTAX PrvtCfmMaintDomainNameOrNone
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Maintenance Domain in the prvtCfmMdTable
to which the MP is associated, or zero-length, if none."
REFERENCE
"802.1ag clause 12.14.2.1.3:b"
::= { prvtCfmStackEntry 5 }
prvtCfmStackMaName OBJECT-TYPE
SYNTAX PrvtCfmMaintAssocNameOrNone
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the MA in the prvtCfmMaTable
to which the MP is associated, or zero-length, if none."
REFERENCE
"802.1ag clause 12.14.2.1.3:c"
::= { prvtCfmStackEntry 6 }
prvtCfmStackMepId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If an MEP is configured, the MEPID, else 0"
REFERENCE
"802.1ag clause 12.14.2.1.3:d"
::= { prvtCfmStackEntry 7 }
prvtCfmStackMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the MP."
REFERENCE
"802.1ag clause 12.14.2.1.3:e"
::= { prvtCfmStackEntry 8 }
prvtCfmMd OBJECT IDENTIFIER
::= { prvtCfmMIBObjects 4 }
prvtCfmMdTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Maintenance Domain table. Each row in the table
represents a different Maintenance Domain.
A Maintenance Domain is described in 802.1ag (3.22) as the
network or the part of the network for which faults in
connectivity are to be managed. The boundary of a Maintenance
Domain is defined by a set of DSAPs, each of which can become
a point of connectivity to a service instance."
REFERENCE
"802.1ag clauses 3.22 and 18.1"
::= { prvtCfmMd 2 }
prvtCfmMdEntry OBJECT-TYPE
SYNTAX PrvtCfmMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Maintenance Domain table entry. This entry is not lost
upon reboot. It is backed up by stable storage."
INDEX { prvtCfmMdName }
::= { prvtCfmMdTable 1 }
PrvtCfmMdEntry ::= SEQUENCE {
prvtCfmMdName PrvtCfmMaintDomainName,
prvtCfmMdRowStatus RowStatus,
prvtCfmMdLevel PrvtCfmMDLevelTC,
prvtCfmMdFormat PrvtCfmMaintDomainNameType,
prvtCfmMdMhfCreation PrvtCfmMhfCreationDef,
prvtCfmMdMhfIdPermission PrvtCfmIdPermissionDef
}
prvtCfmMdName OBJECT-TYPE
SYNTAX PrvtCfmMaintDomainName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Maintenance Domain name.
Each Maintenance Domain has unique name amongst all those
used or available to a service provider or operator. It
facilitates easy identification of administrative
responsibility for each Maintenance Domain.
Clause 3.24 defines a Maintenance Domain name as the
identifier, unique over the domain for which CFM is to
protect against accidental concatenation of Service
Instances, of a particular Maintenance Domain."
REFERENCE
"802.1ag clauses 3.24, 12.14.5, and 21.6.5.3"
::= { prvtCfmMdEntry 1 }
prvtCfmMdRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns must have a valid value before a row
can be activated."
::= { prvtCfmMdEntry 2 }
prvtCfmMdLevel OBJECT-TYPE
SYNTAX PrvtCfmMDLevelTC
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Maintenance Domain Level."
REFERENCE
"802.1ag clause 12.14.5.1.3:b"
::= { prvtCfmMdEntry 4 }
prvtCfmMdFormat OBJECT-TYPE
SYNTAX PrvtCfmMaintDomainNameType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type (and thereby format) of the Maintenance Domain Name."
REFERENCE
"802.1ag clause 21.6.5.1"
::= { prvtCfmMdEntry 5 }
prvtCfmMdMhfCreation OBJECT-TYPE
SYNTAX PrvtCfmMhfCreationDef
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enumerated value indicating whether the management entity can
create MHFs (MIP Half Function) for this Maintenance Domain.
Since, in this variable, there is no encompassing Maintenance
Domain, the value defMHFdefer is not allowed."
REFERENCE
"802.1ag clause 12.14.5.1.3:c"
::= { prvtCfmMdEntry 6 }
prvtCfmMdMhfIdPermission OBJECT-TYPE
SYNTAX PrvtCfmIdPermissionDef
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enumerated value indicating what, if anything, is to be
included in the Sender ID TLV (21.5.3) transmitted by MPs
configured in this Maintenance Domain. Since, in this
variable, there is no encompassing Maintenance Domain, the
value sendIdDefer is not allowed."
REFERENCE
"802.1ag clause 12.14.5.1.3:d"
::= { prvtCfmMdEntry 7 }
prvtCfmMa OBJECT IDENTIFIER
::= { prvtCfmMIBObjects 5 }
prvtCfmMaTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmMaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Maintenance Association table. Each row in the table
represents an MA. An MA is a set of MEPs, each configured
with a single service instance.
The writable objects in this table need to be persistent
upon reboot or restart of a device.
Table includes extra variables needed for Y.1731
support and service awareness"
::= { prvtCfmMa 1 }
prvtCfmMaEntry OBJECT-TYPE
SYNTAX PrvtCfmMaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCfmMaEntry"
INDEX { prvtCfmMdName, prvtCfmMaName }
::= { prvtCfmMaTable 1 }
PrvtCfmMaEntry ::= SEQUENCE {
prvtCfmMaName PrvtCfmMaintAssocName,
prvtCfmMaRowStatus RowStatus,
prvtCfmMaServiceId Unsigned32,
prvtCfmMaVlanId Integer32,
prvtCfmMaMhfCreation PrvtCfmMhfCreation,
prvtCfmMaPermission PrvtCfmIdPermission,
prvtCfmMaFormat PrvtCfmMaintAssocNameType,
prvtCfmMaCcmInterval PrvtCfmCcmInterval,
prvtCfmMaAisLckReceive TruthValue,
prvtCfmMaAisLckLevel Unsigned32,
prvtCfmMaAisLckInterval INTEGER,
prvtCfmMaAisLckPriority Unsigned32,
prvtCfmMaClearConnectivity Unsigned32
}
prvtCfmMaName OBJECT-TYPE
SYNTAX PrvtCfmMaintAssocName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Short Maintenance Association name.
This name must be unique within a maintenance domain."
REFERENCE
"802.1ag clauses 21.6.5.6, and Table 21-20"
::= { prvtCfmMaEntry 1 }
prvtCfmMaRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns must have a valid value before a row
can be activated."
::= { prvtCfmMaEntry 2 }
prvtCfmMaServiceId OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967294)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The primary service ID attached to this MA"
::= { prvtCfmMaEntry 4 }
prvtCfmMaVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The primary vlan ID attached to this MA"
::= { prvtCfmMaEntry 5 }
prvtCfmMaMhfCreation OBJECT-TYPE
SYNTAX PrvtCfmMhfCreation
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates if the Management entity can create MHFs
(MIP Half Function) for this MA."
REFERENCE
"802.1ag clause 12.14.6.1.3:c"
::= { prvtCfmMaEntry 6 }
prvtCfmMaPermission OBJECT-TYPE
SYNTAX PrvtCfmIdPermission
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enumerated value indicating what, if anything, is to be
included in the Sender ID TLV (21.5.3) transmitted by MPs
configured in this MA."
REFERENCE
"802.1ag clause 12.14.6.1.3:d"
::= { prvtCfmMaEntry 7 }
prvtCfmMaFormat OBJECT-TYPE
SYNTAX PrvtCfmMaintAssocNameType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type (and thereby format) of the
Maintenance Association Name."
REFERENCE
"802.1ag clauses 21.6.5.4"
::= { prvtCfmMaEntry 8 }
prvtCfmMaCcmInterval OBJECT-TYPE
SYNTAX PrvtCfmCcmInterval
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Interval between CCM transmissions to be
used by all MEPs in the MA."
REFERENCE
"802.1ag clause 12.14.6.1.3:e"
::= { prvtCfmMaEntry 9 }
prvtCfmMaAisLckReceive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Turn the AIS & LCK features on/off."
REFERENCE
"ITU-T Recommendation Y.1731 clauses 7.4 and 7.6"
::= { prvtCfmMaEntry 10 }
prvtCfmMaAisLckLevel OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The MD level at which AIS & LCK frames will be sent."
REFERENCE
"ITU-T Recommendation Y.1731 clauses 7.4 and 7.6"
::= { prvtCfmMaEntry 11 }
prvtCfmMaAisLckInterval OBJECT-TYPE
SYNTAX INTEGER { interval1s(1), interval1min(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The time interval at which AIS and LCK frames will be sent"
REFERENCE
"ITU-T Recommendation Y.1731 clauses 7.4 and 7.6"
::= { prvtCfmMaEntry 12 }
prvtCfmMaAisLckPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"COS parameter for the outgoing AIS & LCK frames."
REFERENCE
"ITU-T Recommendation Y.1731 clauses 7.4 and 7.6"
::= { prvtCfmMaEntry 13 }
prvtCfmMaClearConnectivity OBJECT-TYPE
SYNTAX Unsigned32 (0..8191)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ID of the MEP to be cleared from the MEP table, or 0 for all"
::= { prvtCfmMaEntry 15 }
prvtCfmMep OBJECT IDENTIFIER
::= { prvtCfmMIBObjects 6 }
prvtCfmMepTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Maintenance Association End Point (MEP) table.
Each row in the table represents a different MEP. A MEP is
an actively managed CFM entity, associated with a specific
DSAP of a Service Instance, which can generate and receive
CFM PDUs and track any responses. It is an end point of a
single Maintenance Association, and is an endpoint of a
separate Maintenance Entity for each of the other MEPs in
the same Maintenance Association (802.1ag clause 3.18).
This table uses three indices. The first two indices are the
indices of the Maintenance Domain and MA tables, the reason
being that a MEP is always related to an MA and Maintenance
Domain.
The MEP table also stores all the managed objects for sending
LBM and LTM.
*LBM Managed objects
LBM Managed objects in the MEP table
enables the management entity to initiate
transmission of Loopback messages. It will signal the MEP
that it should transmit some number of Loopback messages
and detect the detection (or lack thereof) of the
corresponding Loopback messages.
Steps to use entries in this table:
1) Set prvtCfmMepTransmitLbmStatus to true
2) Set the target by:
a) target mep - configue prvtCfmMepTransmitLbmDestIsMepId
on true and then configure prvtCfmMepTransmitLbmDestMepId with
the remote mep id
b) target mac - configue prvtCfmMepTransmitLbmDestIsMepId
on false and then configure prvtCfmMepTransmitLbmDestMacAddress
with the remote device mac address
3) Setup the different data to be sent (number of messages,
optional TLVs,...).
4) Record the current values of prvtCfmMepLbrIn,
prvtCfmMepLbrInOutOfOrder, and prvtCfmMepLbrBadMsdu.
6) Change prvtCfmMepTransmitLbmStatus value to false
to initiate transmission of Loopback messages.
7) Check the value of prvtCfmMepTransmitLbmResultOK to
find out if the operation was successfully initiated or
not.
8) If prvtCfmMepTransmitLbmInfinite is set to false you can
monitor the value of prvtCfmMepTransmitLbmRemainingMessages.
When it reaches 0, the last LBM has been transmitted and
the operation is finished.
Wait an additional 5 seconds to ensure that all LBRs have
been returned.
9) If prvtCfmMepTransmitLbmInfinite is set to true you must stop
the operation yourself by setting prvtCfmMepTransmitLbmStatus to true.
10) Compare prvtCfmMepLbrIn, prvtCfmMepLbrInOutOfOrder,
and prvtCfmMepLbrBadMsdu to their old values from step
4, above, to get the results of the test.
*LTM Managed objects
The LTM Managed objects in the MEP table are used in a manner
similar to that described for LBM transmission, above. Upon
successfully initiating the transmission, the variables
pvrtCfmMepTransmitLtmSeqNumber and
prvtCfmMepTransmitLtmEgressIdentifier return the information
required to recover the results of the LTM from the
prvtCfmLtrTable."
REFERENCE
"802.1ag clauses 12.14.7 and 19.2"
::= { prvtCfmMep 1 }
prvtCfmMepEntry OBJECT-TYPE
SYNTAX PrvtCfmMepEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCfmMepEntry"
INDEX { prvtCfmMdName, prvtCfmMaName, prvtCfmMepIdentifier }
::= { prvtCfmMepTable 1 }
PrvtCfmMepEntry ::= SEQUENCE {
prvtCfmMepIdentifier PrvtCfmMepId,
prvtCfmMepRowStatus RowStatus,
prvtCfmMepInterfaceIndex InterfaceIndex,
prvtCfmMepDirection PrvtCfmMpDirection,
prvtCfmMepShutdown TruthValue,
prvtCfmMepFngState PrvtCfmFngState,
prvtCfmMepCciEnabled TruthValue,
prvtCfmMepCcmLtmPriority Unsigned32,
prvtCfmMepMacAddress MacAddress,
prvtCfmMepLowPrDef PrvtCfmLowestAlarmPri,
prvtCfmMepHighestPrDefect PrvtCfmHighestDefectPri,
prvtCfmMepDefects BITS,
prvtCfmMepErrorCcmLastFailure OCTET STRING,
prvtCfmMepXconCcmLastFailure OCTET STRING,
prvtCfmMepCcmSequenceErrors Counter32,
prvtCfmMepCciSentCcms Counter32,
prvtCfmMepNextLbmTransId Unsigned32,
prvtCfmMepLbrIn Counter32,
prvtCfmMepLbrInOutOfOrder Counter32,
prvtCfmMepLbrBadMsdu Counter32,
prvtCfmMepLtmNextSeqNumber Unsigned32,
prvtCfmMepUnexpLtrIn Counter32,
prvtCfmMepLbrOut Counter32,
prvtCfmMepTransmitLbmStatus TruthValue,
prvtCfmMepTransmitLbmDestMacAddress MacAddress,
prvtCfmMepTransmitLbmDestMepId PrvtCfmMepIdOrZero,
prvtCfmMepTransmitLbmDestIsMepId TruthValue,
prvtCfmMepTransmitLbmMessages Integer32,
prvtCfmMepTransmitLbmDataTlv OCTET STRING,
prvtCfmMepTransmitLbmVlanPriority Integer32,
prvtCfmMepTransmitLbmVlanDropEnable TruthValue,
prvtCfmMepTransmitLbmResultOK TruthValue,
prvtCfmMepTransmitLbmSeqNumber Unsigned32,
prvtCfmMepTransmitLtmStatus TruthValue,
prvtCfmMepTransmitLtmFlags BITS,
prvtCfmMepTransmitLtmTargetMacAddress MacAddress,
prvtCfmMepTransmitLtmTargetMepId PrvtCfmMepIdOrZero,
prvtCfmMepTransmitLtmTargetIsMepId TruthValue,
prvtCfmMepTransmitLtmTtl Unsigned32,
prvtCfmMepTransmitLtmResult TruthValue,
prvtCfmMepTransmitLtmSeqNumber Unsigned32,
prvtCfmMepTransmitLtmEgressIdentifier OCTET STRING,
prvtCfmMepAlarmSupressed TruthValue,
prvtCfmMepAisCondition TruthValue,
prvtCfmMepLckCondition TruthValue,
prvtCfmMepAisLifetime INTEGER,
prvtCfmMepLckLifetime INTEGER,
prvtCfmMepTransmitMcastLbm TruthValue,
prvtCfmMepTransmitLbmInfinite TruthValue,
prvtCfmMepTransmitLbmDelay Unsigned32,
prvtCfmMepTransmitLbmTimeout Unsigned32,
prvtCfmMepTransmitLtmTimeout Unsigned32,
prvtCfmMepTransmitLbmSentPkts Unsigned32,
prvtCfmMepTransmitLbmSuccessRate Unsigned32,
prvtCfmMepTransmitLbmMinTime Unsigned32,
prvtCfmMepTransmitLbmAvgTime Unsigned32,
prvtCfmMepTransmitLbmMaxTime Unsigned32,
prvtCfmMepFngAlarmTime Unsigned32,
prvtCfmMepFngResetTime Unsigned32,
prvtCfmMepTransmitLbmRemainingMessages Integer32,
prvtCfmMepTransmitLbmCurrentStatus TruthValue
}
prvtCfmMepIdentifier OBJECT-TYPE
SYNTAX PrvtCfmMepId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Integer that is unique among all the MEPs in the same MA.
Other definition is: a small integer, unique over a given
Maintenance Association, identifying a specific Maintenance
association End Point (3.19).
MEP Identifier is also known as the MEPID."
REFERENCE
"802.1ag clauses 3.19, 19.2 and 12.14.7"
::= { prvtCfmMepEntry 1 }
prvtCfmMepRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns must have a valid value before a row
can be activated."
::= { prvtCfmMepEntry 2 }
prvtCfmMepInterfaceIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is the interface index (from ifTable) of either
a bridge port, or an aggregated IEEE 802.1 link,
to which the MEP is attached."
REFERENCE
"802.1ag clause 12.14.7.1.3:b"
::= { prvtCfmMepEntry 3 }
prvtCfmMepDirection OBJECT-TYPE
SYNTAX PrvtCfmMpDirection
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The direction in which the MEP faces on the Bridge port."
REFERENCE
"802.1ag clauses 12.14.7.1.3:c and 19.2"
::= { prvtCfmMepEntry 4 }
prvtCfmMepShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Administrative state of the MEP
The value 'true' will shutdown/disable the MEP.
The value 'false' will enable the MEP."
REFERENCE
"802.1ag clauses 12.14.7.1.3:e and 20.9.1"
::= { prvtCfmMepEntry 5 }
prvtCfmMepFngState OBJECT-TYPE
SYNTAX PrvtCfmFngState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current state of the MEP Fault Notification Generator
State Machine."
REFERENCE
"802.1ag clauses 12.14.7.1.3:f and 20.35"
::= { prvtCfmMepEntry 6 }
prvtCfmMepCciEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If set to true, the MEP will generate CCM messages."
REFERENCE
"802.1ag clauses 12.14.7.1.3:g and 20.10.1"
::= { prvtCfmMepEntry 7 }
prvtCfmMepCcmLtmPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The priority value for CCMs and LTMs transmitted by the MEP.
Default Value is the highest priority value allowed to pass
through the bridge port for any of this MEPs VIDs.
The management entity can obtain the default value for this
variable from the priority regeneration table by extracting the
highest priority value in this table on this MEPs bridge port.
(1 is lowest, then 2, then 0, then 3-7)."
REFERENCE
"802.1ag clause 12.14.7.1.3:h"
::= { prvtCfmMepEntry 8 }
prvtCfmMepMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the MEP."
REFERENCE
"802.1ag clause 12.14.7.1.3:i and 19.4"
::= { prvtCfmMepEntry 9 }
prvtCfmMepLowPrDef OBJECT-TYPE
SYNTAX PrvtCfmLowestAlarmPri
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An integer value specifying the lowest priority defect
that is allowed to generate fault alarm."
REFERENCE
"802.1ag clause 12.14.7.1.3:k and 20.9.5 and Table 20-1"
::= { prvtCfmMepEntry 10 }
prvtCfmMepHighestPrDefect OBJECT-TYPE
SYNTAX PrvtCfmHighestDefectPri
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest priority defect that has been present since the
MEPs Fault Notification Generator State Machine was last in
the FNG_RESET state."
REFERENCE
"802.1ag clause 12.14.7.1.3:n 20.33.9 and Table 21-1"
::= { prvtCfmMepEntry 11 }
prvtCfmMepDefects OBJECT-TYPE
SYNTAX BITS { bDefRDICCM(0), bDefMACstatus(1), bDefRemoteCCM(2),
bDefErrorCCM(3), bDefXconCCM(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A vector of Boolean error conditions from Table 20-1, any of
which may be true."
REFERENCE
".1ag clauses 12.14.7.1.3:o, 12.14.7.1.3:p, 12.14.7.1.3:q,
12.14.7.1.3:r, 12.14.7.1.3:s, 20.21.3, 20.23.3, 20.33.5,
20.33.6, 20.33.7."
::= { prvtCfmMepEntry 12 }
prvtCfmMepErrorCcmLastFailure OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last-received CCM that triggered an DefErrorCCM fault."
REFERENCE
"802.1ag clauses 12.14.7.1.3:t and 20.21.2"
::= { prvtCfmMepEntry 13 }
prvtCfmMepXconCcmLastFailure OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last-received CCM that triggered a DefXconCCM fault."
REFERENCE
"802.1ag clauses 12.14.7.1.3:u and 20.23.2"
::= { prvtCfmMepEntry 14 }
prvtCfmMepCcmSequenceErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of out-of-sequence CCMs received from all
remote MEPs."
REFERENCE
"802.1ag clauses 12.14.7.1.3:v and 20.16.12"
::= { prvtCfmMepEntry 15 }
prvtCfmMepCciSentCcms OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of Continuity Check messages transmitted."
REFERENCE
"802.1ag clauses 12.14.7.1.3:w and 20.10.2"
::= { prvtCfmMepEntry 16 }
prvtCfmMepNextLbmTransId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Next sequence number/transaction identifier to be sent in a
Loopback message. This sequence number can be zero because
it wraps around."
REFERENCE
"802.1ag clauses 12.14.7.1.3:x and 20.28.2"
::= { prvtCfmMepEntry 17 }
prvtCfmMepLbrIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of valid, in-order Loopback Replies received."
REFERENCE
"802.1ag clause 12.14.7.1.3:y and 20.31.1"
::= { prvtCfmMepEntry 18 }
prvtCfmMepLbrInOutOfOrder OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid, out-of-order Loopback Replies
received."
REFERENCE
"802.1ag clause 12.14.7.1.3:z and 20.31.1"
::= { prvtCfmMepEntry 19 }
prvtCfmMepLbrBadMsdu OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of LBRs received whose
mac_service_data_unit did not match (except for the OpCode)
that of the corresponding LBM (20.2.3)."
REFERENCE
"802.1ag clause 12.14.7.1.3:aa 20.2.3"
::= { prvtCfmMepEntry 20 }
prvtCfmMepLtmNextSeqNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Next transaction identifier/sequence number to be sent in a
Linktrace message. This sequence number can be zero because
it wraps around."
REFERENCE
"802.1ag clause 12.14.7.1.3:ab and 20.36.1"
::= { prvtCfmMepEntry 21 }
prvtCfmMepUnexpLtrIn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of unexpected LTRs received (20.39.1)."
REFERENCE
"802.1ag clause 12.14.7.1.3:ac 20.39.1"
::= { prvtCfmMepEntry 22 }
prvtCfmMepLbrOut OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of Loopback Replies transmitted."
REFERENCE
"802.1ag clause 12.14.7.1.3:ad and 20.26.2"
::= { prvtCfmMepEntry 23 }
prvtCfmMepTransmitLbmStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A Boolean flag set to true by the bridge port to indicate
that another LBM may be transmitted.
Reset to false by the MEP Loopback Initiator State Machine."
::= { prvtCfmMepEntry 24 }
prvtCfmMepTransmitLbmDestMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Target MAC Address Field to be transmitted: A unicast
destination MAC address.
This address will be used if the value of the column
prvtCfmMepTransmitLbmDestIsMepId is 'false'."
REFERENCE
"802.1ag clause 12.14.7.3.2:b"
::= { prvtCfmMepEntry 25 }
prvtCfmMepTransmitLbmDestMepId OBJECT-TYPE
SYNTAX PrvtCfmMepIdOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Maintenance association End Point Identifier of another
MEP in the same Maintenance Association to which the LBM is
to be sent.
This address will be used if the value of the column
prvtCfmMepTransmitLbmDestIsMepId is 'true'."
REFERENCE
"802.1ag clause 12.14.7.3.2:b"
::= { prvtCfmMepEntry 26 }
prvtCfmMepTransmitLbmDestIsMepId OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"True indicates that MEPID of the target MEP is used for
Loopback transmission.
False indicates that unicast destination MAC address of the
target MEP is used for Loopback transmission."
REFERENCE
"802.1ag clause 12.14.7.3.2:b"
::= { prvtCfmMepEntry 27 }
prvtCfmMepTransmitLbmMessages OBJECT-TYPE
SYNTAX Integer32 (1..1024)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of Loopback messages to be transmitted."
REFERENCE
"802.1ag clause 12.14.7.3.2:c"
::= { prvtCfmMepEntry 28 }
prvtCfmMepTransmitLbmDataTlv OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..1462))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An arbitrary amount of data to be included in the Data TLV,
if the Data TLV is selected to be sent."
REFERENCE
"802.1ag clause 12.14.7.3.2:d"
::= { prvtCfmMepEntry 29 }
prvtCfmMepTransmitLbmVlanPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Priority. 3 bit value to be used in the VLAN tag, if present
in the transmitted frame.
The default value is CCM priority."
REFERENCE
"802.1ag clause 12.14.7.3.2:e"
::= { prvtCfmMepEntry 30 }
prvtCfmMepTransmitLbmVlanDropEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Drop Enable bit value to be used in the VLAN tag, if present
in the transmitted frame.
For more information about VLAN Drop Enable, please check
IEEE 802.1ad."
REFERENCE
"802.1ag clause 12.14.7.3.2:e"
::= { prvtCfmMepEntry 31 }
prvtCfmMepTransmitLbmResultOK OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the result of the operation:
- true The Loopback Message(s) will be
(or has been) sent.
- false The Loopback Message(s) will not
be sent."
REFERENCE
"802.1ag clause 12.14.7.3.3:a"
::= { prvtCfmMepEntry 32 }
prvtCfmMepTransmitLbmSeqNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Loopback Transaction Identifier
(prvtCfmMepNextLbmTransId) of the first LBM (to be) sent.
The value returned is undefined if
prvtCfmMepTransmitLbmResultOK is false."
REFERENCE
"802.1ag clause 12.14.7.3.3:a"
::= { prvtCfmMepEntry 33 }
prvtCfmMepTransmitLtmStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A Boolean flag set to true by the bridge port to indicate
that another LTM may be transmitted.
In order to start linktrace following step should be executed:
1.Verify CFM connectivity
2.Set prvtCfmMepTransmitLtmTargetIsMepId to TRUE (if using target Mep)
3.Set prvtCfmMepTransmitLtmTargetMepId with the remote Mep Id
4.Set prvtCfmMepTransmitLtmTimeout (timeout for LTM packets)
5.Set prvtCfmMepTransmitLtmStatus to TRUE"
::= { prvtCfmMepEntry 34 }
prvtCfmMepTransmitLtmFlags OBJECT-TYPE
SYNTAX BITS { useFDBonly(0) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The flags field for LTMs transmitted by the MEP."
REFERENCE
"802.1ag clause 12.14.7.4.2:b and 20.37.1"
::= { prvtCfmMepEntry 35 }
prvtCfmMepTransmitLtmTargetMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Target MAC Address Field to be transmitted: A unicast
destination MAC address.
This address will be used if the value of the column
prvtCfmMepTransmitLtmTargetIsMepId is 'false'."
REFERENCE
"802.1ag clause 12.14.7.4.2:c"
::= { prvtCfmMepEntry 36 }
prvtCfmMepTransmitLtmTargetMepId OBJECT-TYPE
SYNTAX PrvtCfmMepIdOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An indication of the Target MAC Address Field to be
transmitted:
The Maintenance association End Point Identifier of
another MEP in the same Maintenance Association
This address will be used if the value of the column
prvtCfmMepTransmitLtmTargetIsMepId is 'true'."
REFERENCE
"802.1ag clause 12.14.7.4.2:c"
::= { prvtCfmMepEntry 37 }
prvtCfmMepTransmitLtmTargetIsMepId OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"True indicates that MEPID of the target MEP is used for
Linktrace transmission.
False indicates that unicast destination MAC address of the
target MEP is used for Loopback transmission."
REFERENCE
"802.1ag clause 12.14.7.4.2:c"
::= { prvtCfmMepEntry 38 }
prvtCfmMepTransmitLtmTtl OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The LTM TTL field. Default value, if not specified, is 64.
The TTL field indicates the number of hops remaining to the
LTM. Decremented by 1 by each Linktrace Responder that
handles the LTM. The value returned in the LTR is one less
than that received in the LTM. If the LTM TTL is 0 or 1, the
LTM is not forwarded to the next hop, and if 0, no LTR is
generated."
REFERENCE
"802.1ag clause 12.14.7.4.2:d and 21.8.4"
::= { prvtCfmMepEntry 39 }
prvtCfmMepTransmitLtmResult OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the result of the operation:
- true The Linktrace Message will be (or has been) sent.
- false The Linktrace Message will not be sent"
REFERENCE
"802.1ag clause 12.14.7.4.3:a"
::= { prvtCfmMepEntry 40 }
prvtCfmMepTransmitLtmSeqNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The LTM Transaction Identifier
(prvtCfmMepLtmNextSeqNumber) of the LTM sent.
The value returned is undefined if
prvtCfmMepTransmitLtmResult is false."
REFERENCE
"802.1ag clause 12.14.7.4.3:a"
::= { prvtCfmMepEntry 41 }
prvtCfmMepTransmitLtmEgressIdentifier OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Identifies the MEP Linktrace Initiator that is originating,
or the Linktrace Responder that is forwarding, this LTM.
The low-order six octets contain a 48-bit IEEE MAC address
unique to the system in which the MEP Linktrace Initiator
or Linktrace Responder resides. The high-order two octets
contain a value sufficient to uniquely identify the MEP
Linktrace Initiator or Linktrace Responder within that system.
For most Bridges, the address of any MAC attached to the
Bridge will suffice for the low-order six octets, and 0 for
the high-order octets. In some situations, e.g. if multiple
virtual Bridges utilizing emulated LANs are implemented in a
single physical system, the high-order two octets can be used
to differentiate among the transmitting entities.
The value returned is undefined if
prvtCfmMepTransmitLtmResult is false."
REFERENCE
"802.1ag clause 12.14.7.4.3:b and 21.8.8"
::= { prvtCfmMepEntry 42 }
prvtCfmMepAlarmSupressed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A boolean showing if an AIS or LCK packet
was received from a lower level"
::= { prvtCfmMepEntry 43 }
prvtCfmMepAisCondition OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"AIS condition
Is true by detection of signal
fail condition at a Server layer or reception of AIS at a
server (sub-) layer MEP [AIS condition/Rec. ITU-T Y.1731]
Respectively AIS condition Exit criteria:
'During an interval equal to 3.5 times the AIS transmission
period indicated in the AIS frames received earlier,
the MEP does not receive AIS frames or,
when ETH-CC is used, upon clearing of LOC defect at
MEP' /Appendix I/Rec. ITU-T Y.1731
If prvtCfmMaAisLckLevel is configured the MEP should send AIS packets"
REFERENCE
"ITU-T Recommendation Y.1731 APPENDIX I Defect Conditions,
I.7 AIS Condition"
::= { prvtCfmMepEntry 44 }
prvtCfmMepLckCondition OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A boolean showing if the MEP should lock the service
towards the client and send LCK packets"
REFERENCE
"ITU-T Recommendation Y.1731 APPENDIX I Defect Conditions,
I.9 LCK Condition"
::= { prvtCfmMepEntry 45 }
prvtCfmMepAisLifetime OBJECT-TYPE
SYNTAX INTEGER { none(0), lifetime35s(1), lifetime35min(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lifetime of the last received AIS packet"
REFERENCE
"ITU-T Recommendation Y.1731 APPENDIX I Defect Conditions,
I.7 AIS Condition"
::= { prvtCfmMepEntry 46 }
prvtCfmMepLckLifetime OBJECT-TYPE
SYNTAX INTEGER { none(0), lifetime35s(1), lifetime35min(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lifetime of the last received LCK packet"
REFERENCE
"ITU-T Recommendation Y.1731 APPENDIX I Defect Conditions,
I.9 LCK Condition"
::= { prvtCfmMepEntry 47 }
prvtCfmMepTransmitMcastLbm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A boolean to control sending Y.1731 multicast loopback."
::= { prvtCfmMepEntry 48 }
prvtCfmMepTransmitLbmInfinite OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A boolean to control sending LBMs continuously until the
operation is explicitly stopped by setting this back to false"
::= { prvtCfmMepEntry 49 }
prvtCfmMepTransmitLbmDelay OBJECT-TYPE
SYNTAX Unsigned32 (0..60)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An amount of time to wait between sent LBMs (in seconds)."
::= { prvtCfmMepEntry 50 }
prvtCfmMepTransmitLbmTimeout OBJECT-TYPE
SYNTAX Unsigned32 (1..60)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An amount of time to wait after the last sent LBM if no
LBR is received (in seconds)."
::= { prvtCfmMepEntry 51 }
prvtCfmMepTransmitLtmTimeout OBJECT-TYPE
SYNTAX Unsigned32 (1..60)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An amount of time to wait after the last sent LTM if no
LTR is received (in seconds)."
::= { prvtCfmMepEntry 52 }
prvtCfmMepTransmitLbmSentPkts OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of successfully sent packets in the current LBM
session."
::= { prvtCfmMepEntry 53 }
prvtCfmMepTransmitLbmSuccessRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Success rate of the current LBM session (in percentage*100)."
::= { prvtCfmMepEntry 54 }
prvtCfmMepTransmitLbmMinTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum LBR response time (in msec)."
::= { prvtCfmMepEntry 55 }
prvtCfmMepTransmitLbmAvgTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average LBR response time (in msec)."
::= { prvtCfmMepEntry 56 }
prvtCfmMepTransmitLbmMaxTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum LBR response time (in msec)."
::= { prvtCfmMepEntry 57 }
prvtCfmMepFngAlarmTime OBJECT-TYPE
SYNTAX Unsigned32 (250..1000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The time that defects must be present before a Fault Alarm is
issued (fngAlarmTime. 20.33.3) (default 2.5s)."
REFERENCE
"802.1ag clauses 12.14.7.1.3:l and 20.33.3"
::= { prvtCfmMepEntry 58 }
prvtCfmMepFngResetTime OBJECT-TYPE
SYNTAX Unsigned32 (250..1000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The time that defects must be absent before re-enabling a
Fault Alarm (fngResetTime, 20.33.4) (default 10s)."
REFERENCE
"802.1ag clauses 12.14.7.1.3:m and 20.33.4"
::= { prvtCfmMepEntry 59 }
prvtCfmMepTransmitLbmRemainingMessages OBJECT-TYPE
SYNTAX Integer32 (0..1024)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of LBMs (Loopback messages) to be transmitted"
::= { prvtCfmMepEntry 60 }
prvtCfmMepTransmitLbmCurrentStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Boolean flag set to true by the bridge port to indicate
that another LBM may be transmitted.
Reset to false by the MEP Loopback Initiator State Machine."
::= { prvtCfmMepEntry 61 }
prvtCfmMepDbTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmMepDbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEP Database. A database, maintained by every MEP, that
maintains received information about other MEPs in the
Maintenance Domain.
The SMI does not allow to state in a MIB that an object in
a table is an array. The solution is to take the index (or
indices) of the first table and add one or more indices."
REFERENCE
"802.1ag clause 19.2.15"
::= { prvtCfmMep 2 }
prvtCfmMepDbEntry OBJECT-TYPE
SYNTAX PrvtCfmMepDbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MEP Database table entry."
INDEX { prvtCfmMdName, prvtCfmMaName, prvtCfmMepIdentifier,
prvtCfmMepDbRMepIdentifier }
::= { prvtCfmMepDbTable 1 }
PrvtCfmMepDbEntry ::= SEQUENCE {
prvtCfmMepDbRMepIdentifier Unsigned32,
prvtCfmMepDbRMepState PrvtCfmRemoteMepState,
prvtCfmMepDbRMepFailedOkTime TimeStamp,
prvtCfmMepDbMacAddress MacAddress,
prvtCfmMepDbRdi TruthValue,
prvtCfmMepDbPortStatusTlv PrvtCfmPortStatus,
prvtCfmMepDbInterfaceStatusTlv PrvtCfmInterfaceStatus,
prvtCfmMepDbChassisIdSubtype LldpChassisIdSubtype,
prvtCfmMepDbChassisId LldpChassisId,
prvtCfmMepDbManAddressDomain TDomain,
prvtCfmMepDbManAddress TAddress
}
prvtCfmMepDbRMepIdentifier OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Maintenance association End Point Identifier of a remote MEP
whose information from the MEP Database is to be returned."
REFERENCE
"802.1ag clause 12.14.7.6.2:b"
::= { prvtCfmMepDbEntry 1 }
prvtCfmMepDbRMepState OBJECT-TYPE
SYNTAX PrvtCfmRemoteMepState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state of the remote MEP IFF State machines."
REFERENCE
"802.1ag clause 12.14.7.6.3:b and 20.22"
::= { prvtCfmMepDbEntry 2 }
prvtCfmMepDbRMepFailedOkTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time (SysUpTime) at which the IFF Remote MEP state machine
last entered either the RMEP_FAILED or RMEP_OK state."
REFERENCE
"802.1ag clause 12.14.7.6.3:c"
::= { prvtCfmMepDbEntry 3 }
prvtCfmMepDbMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of the remote MEP."
REFERENCE
"802.1ag clause 12.14.7.6.3:d and 20.19.7"
::= { prvtCfmMepDbEntry 4 }
prvtCfmMepDbRdi OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the RDI bit in the last received CCM (true for
RDI=1), or false if none has been received."
REFERENCE
"802.1ag clauses 12.14.7.6.3:e and 20.19.2"
::= { prvtCfmMepDbEntry 5 }
prvtCfmMepDbPortStatusTlv OBJECT-TYPE
SYNTAX PrvtCfmPortStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An enumerated value of the Port status TLV received in the
last CCM from the remote MEP or the default value
psNoPortStateTLV indicating either no CCM has been received,
or that nor port status TLV was received in the last CCM."
REFERENCE
"802.1ag clause 12.14.7.6.3:f and 20.19.3"
::= { prvtCfmMepDbEntry 6 }
prvtCfmMepDbInterfaceStatusTlv OBJECT-TYPE
SYNTAX PrvtCfmInterfaceStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An enumerated value of the Interface status TLV received
in the last CCM from the remote MEP or the default value
isNoInterfaceStatus TLV indicating either no CCM has been
received, or that no interface status TLV was received in
the last CCM."
REFERENCE
"802.1ag clause 12.14.7.6.3:g and 20.19.4"
::= { prvtCfmMepDbEntry 7 }
prvtCfmMepDbChassisIdSubtype OBJECT-TYPE
SYNTAX LldpChassisIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the format of the Chassis ID received
in the last CCM."
REFERENCE
"802.1ag clauses 12.14.7.6.3:h and 21.5.3.2"
::= { prvtCfmMepDbEntry 8 }
prvtCfmMepDbChassisId OBJECT-TYPE
SYNTAX LldpChassisId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Chassis ID. The format of this object is determined by the
value of the prvtCfmLtrChassisIdSubtype object."
REFERENCE
"802.1ag clauses 12.14.7.6.3:h and 21.5.3.3"
::= { prvtCfmMepDbEntry 9 }
prvtCfmMepDbManAddressDomain OBJECT-TYPE
SYNTAX TDomain
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The TDomain that identifies the type and format of
the related prvtCfmMepDbManAddress object, used to access
the SNMP agent of the system transmitting the CCM. Received
in the CCM Sender ID TLV from that system.
Typical values will be one of (not all inclusive) list:
snmpUDPDomain (from SNMPv2-TM, RFC3417)
snmpIeee802Domain (from SNMP-IEEE802-TM-MIB, RFC4789)
The value 'zeroDotZero' (from RFC2578) indicates 'no LTR
Sender ID TLV received', in which case the related object
prvtCfmMepDbManAddress must have a zero-length OCTET STRING
as a value."
REFERENCE
"802.1ag clauses 12.14.7.6.3:h, 21.5.3.5, 21.6.7"
::= { prvtCfmMepDbEntry 10 }
prvtCfmMepDbManAddress OBJECT-TYPE
SYNTAX TAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The TAddress that can be used to access the SNMP
agent of the system transmitting the CCM, received in the CCM
Sender ID TLV from that system.
If the related object prvtCfmMepDbManAddressDomain contains
the value 'zeroDotZero', this object prvtCfmMepDbManAddress
must have a zero-length OCTET STRING as a value."
REFERENCE
"802.1ag clauses 12.14.7.6.3:h, 21.5.3.7, 21.6.7"
::= { prvtCfmMepDbEntry 11 }
prvtCfmLtrTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmLtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table extends the MEP table and contains a list of
Linktrace replies received by a specific MEP in response to
a linktrace message.
SNMP SMI does not allow to state in a MIB that an object in
a table is an array. The solution is to take the index (or
indices) of the first table and add one or more indices."
REFERENCE
"802.1ag clause 12.14.7.5"
::= { prvtCfmMep 3 }
prvtCfmLtrEntry OBJECT-TYPE
SYNTAX PrvtCfmLtrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Linktrace Reply table entry."
INDEX { prvtCfmMdName, prvtCfmMaName, prvtCfmMepIdentifier,
prvtCfmLtrSeqNumber, prvtCfmLtrReceiveOrder }
::= { prvtCfmLtrTable 1 }
PrvtCfmLtrEntry ::= SEQUENCE {
prvtCfmLtrSeqNumber Unsigned32,
prvtCfmLtrReceiveOrder Unsigned32,
prvtCfmLtrTtl Unsigned32,
prvtCfmLtrForwarded TruthValue,
prvtCfmLtrTerminalMep TruthValue,
prvtCfmLtrLastEgressIdentifier OCTET STRING,
prvtCfmLtrNextEgressIdentifier OCTET STRING,
prvtCfmLtrRelay PrvtCfmRelayActionFieldValue,
prvtCfmLtrChassisIdSubtype LldpChassisIdSubtype,
prvtCfmLtrChassisId LldpChassisId,
prvtCfmLtrManAddressDomain TDomain,
prvtCfmLtrManAddress TAddress,
prvtCfmLtrIngress PrvtCfmIngressActionFieldValue,
prvtCfmLtrIngressMac MacAddress,
prvtCfmLtrIngressPortIdSubtype LldpPortIdSubtype,
prvtCfmLtrIngressPortId LldpPortId,
prvtCfmLtrEgress PrvtCfmEgressActionFieldValue,
prvtCfmLtrEgressMac MacAddress,
prvtCfmLtrEgressPortIdSubtype LldpPortIdSubtype,
prvtCfmLtrEgressPortId LldpPortId,
prvtCfmLtrOrganizationSpecificTlv OCTET STRING,
prvtCfmLtrTime Unsigned32,
prvtCfmLtrSourceMac MacAddress
}
prvtCfmLtrSeqNumber OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Transaction identifier/Sequence number returned by a previous
transmit linktrace message command, indicating which LTM's
response is going to be returned."
REFERENCE
"802.1ag clause 12.14.7.5.2:b"
::= { prvtCfmLtrEntry 1 }
prvtCfmLtrReceiveOrder OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index to distinguish among multiple LTRs with the same LTR
Transaction Identifier field value. prvtCfmLtrReceiveOrder
are assigned sequentially from 1, in the order that the
Linktrace Initiator received the LTRs."
REFERENCE
"802.1ag clause 12.14.7.5.2:c"
::= { prvtCfmLtrEntry 2 }
prvtCfmLtrTtl OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TTL field value for a returned LTR."
REFERENCE
"802.1ag clause 12.14.7.5 and 20.36.2.2"
::= { prvtCfmLtrEntry 3 }
prvtCfmLtrForwarded OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if a LTM was forwarded by the responding MP, as
returned in the 'FwdYes' flag of the flags field."
REFERENCE
"802.1ag clauses 12.14.7.5.3:c and 20.36.2.1"
::= { prvtCfmLtrEntry 4 }
prvtCfmLtrTerminalMep OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A boolean value stating whether the forwarded LTM reached a
MEP enclosing its MA, as returned in the Terminal MEP flag of
the Flags field."
REFERENCE
"802.1ag clauses 12.14.7.5.3:d and 20.36.2.1"
::= { prvtCfmLtrEntry 5 }
prvtCfmLtrLastEgressIdentifier OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An octet field holding the Last Egress Identifier returned
in the LTR Egress Identifier TLV of the LTR.
The Last Egress Identifier identifies the MEP Linktrace
Initiator that originated, or the Linktrace Responder that
forwarded, the LTM to which this LTR is the response. This
is the same value as the Egress Identifier TLV of that LTM."
REFERENCE
"802.1ag clauses 12.14.7.5.3:e and 20.36.2.3"
::= { prvtCfmLtrEntry 6 }
prvtCfmLtrNextEgressIdentifier OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An octet field holding the Next Egress Identifier returned
in the LTR Egress Identifier TLV of the LTR. The Next Egress
Identifier Identifies the Linktrace Responder that
transmitted this LTR, and can forward the LTM to the next
hop. This is the same value as the Egress Identifier TLV of
the forwarded LTM, if any. If the FwdYes bit of the Flags
field is false, the contents of this field are undefined,
i.e. any value can be transmitted, and the field is ignored
by the receiver."
REFERENCE
"802.1ag clauses 12.14.7.5.3:f and 20.36.2.4"
::= { prvtCfmLtrEntry 7 }
prvtCfmLtrRelay OBJECT-TYPE
SYNTAX PrvtCfmRelayActionFieldValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value returned in the Relay Action field."
REFERENCE
"802.1ag clauses 12.14.7.5.3:g and 20.36.2.5"
::= { prvtCfmLtrEntry 8 }
prvtCfmLtrChassisIdSubtype OBJECT-TYPE
SYNTAX LldpChassisIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the format of the Chassis ID returned
in the Sender ID TLV of the LTR, if any. This value is
meaningless if the prvtCfmLtrChassisId has a length of 0."
REFERENCE
"802.1ag clauses 12.14.7.5.3:h and 21.5.3.2"
::= { prvtCfmLtrEntry 9 }
prvtCfmLtrChassisId OBJECT-TYPE
SYNTAX LldpChassisId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Chassis ID returned in the Sender ID TLV of the LTR, if
any. The format of this object is determined by the
value of the prvtCfmLtrChassisIdSubtype object."
REFERENCE
"802.1ag clauses 12.14.7.5.3:i and 21.5.3.3"
::= { prvtCfmLtrEntry 10 }
prvtCfmLtrManAddressDomain OBJECT-TYPE
SYNTAX TDomain
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The TDomain that identifies the type and format of
the related prvtCfmLtrManAddress object, used to access
the SNMP agent of the system transmitting the LTR. Received
in the LTR Sender ID TLV from that system.
Typical values will be one of (not all inclusive) list:
snmpUDPDomain (from SNMPv2-TM, RFC3417)
snmpIeee802Domain (from SNMP-IEEE802-TM-MIB, RFC4789)
The value 'zeroDotZero' (from RFC2578) indicates 'no LTR
Sender ID TLV received', in which case the related object
prvtCfmLtrManAddress must have a zero-length OCTET STRING
as a value."
REFERENCE
"802.1ag clauses 12.14.7.5.3:j, 21.5.3.5, 21.9.6"
::= { prvtCfmLtrEntry 11 }
prvtCfmLtrManAddress OBJECT-TYPE
SYNTAX TAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The TAddress that can be used to access the SNMP
agent of the system transmitting the CCM, received in the CCM
Sender ID TLV from that system.
If the related object prvtCfmLtrManAddressDomain contains
the value 'zeroDotZero', this object prvtCfmLtrManAddress
must have a zero-length OCTET STRING as a value."
REFERENCE
"802.1ag clauses 12.14.7.5.3:j, 21.5.3.7, 21.9.6"
::= { prvtCfmLtrEntry 12 }
prvtCfmLtrIngress OBJECT-TYPE
SYNTAX PrvtCfmIngressActionFieldValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value returned in the Ingress Action Field of the LTM."
REFERENCE
"802.1ag clauses 12.14.7.5.3:k and 20.36.2.6"
::= { prvtCfmLtrEntry 13 }
prvtCfmLtrIngressMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address returned in the ingress MAC address field."
REFERENCE
"802.1ag clauses 12.14.7.5.3:l and 20.36.2.7"
::= { prvtCfmLtrEntry 14 }
prvtCfmLtrIngressPortIdSubtype OBJECT-TYPE
SYNTAX LldpPortIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Format of the Ingress Port ID."
REFERENCE
"802.1ag clauses 12.14.7.5.3:m and 20.36.2.8"
::= { prvtCfmLtrEntry 15 }
prvtCfmLtrIngressPortId OBJECT-TYPE
SYNTAX LldpPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ingress Port ID. The format of this object is determined by
the value of the prvtCfmLtrIngressPortIdSubtype object."
REFERENCE
"802.1ag clauses 12.14.7.5.3:n and 20.36.2.9"
::= { prvtCfmLtrEntry 16 }
prvtCfmLtrEgress OBJECT-TYPE
SYNTAX PrvtCfmEgressActionFieldValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value returned in the Egress Action Field of the LTM."
REFERENCE
"802.1ag clauses 12.14.7.5.3:o and 20.36.2.10"
::= { prvtCfmLtrEntry 17 }
prvtCfmLtrEgressMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address returned in the egress MAC address field."
REFERENCE
"802.1ag clauses 12.14.7.5.3:p and 20.36.2.11"
::= { prvtCfmLtrEntry 18 }
prvtCfmLtrEgressPortIdSubtype OBJECT-TYPE
SYNTAX LldpPortIdSubtype
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Format of the egress Port ID."
REFERENCE
"802.1ag clauses 12.14.7.5.3:q and 20.36.2.12"
::= { prvtCfmLtrEntry 19 }
prvtCfmLtrEgressPortId OBJECT-TYPE
SYNTAX LldpPortId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Egress Port ID. The format of this object is determined by
the value of the prvtCfmLtrEgressPortIdSubtype object."
REFERENCE
"802.1ag clauses 12.14.7.5.3:r and 20.36.2.13"
::= { prvtCfmLtrEntry 20 }
prvtCfmLtrOrganizationSpecificTlv OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All Organization specific TLVs returned in the LTR, if
any. Includes all octets including and following the TLV
Length field of each TLV, concatenated together."
REFERENCE
"802.1ag clauses 12.14.7.5.3:s, 21.5.2"
::= { prvtCfmLtrEntry 21 }
prvtCfmLtrTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote MPs response time in milliseconds."
::= { prvtCfmLtrEntry 22 }
prvtCfmLtrSourceMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address that originated the LTR."
::= { prvtCfmLtrEntry 23 }
prvtCfmLbrTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmLbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table contains loopback results following the last loopback operation."
::= { prvtCfmMep 4 }
prvtCfmLbrEntry OBJECT-TYPE
SYNTAX PrvtCfmLbrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCfmLbrEntry"
INDEX { prvtCfmMdName, prvtCfmMaName, prvtCfmMepIdentifier,
prvtCfmLbrSeqNumber, prvtCfmLbrReceiveOrder }
::= { prvtCfmLbrTable 1 }
PrvtCfmLbrEntry ::= SEQUENCE {
prvtCfmLbrSeqNumber Unsigned32,
prvtCfmLbrReceiveOrder Unsigned32,
prvtCfmLbrTime Unsigned32,
prvtCfmLbrMacAddress MacAddress,
prvtCfmLbrBadMsdu TruthValue
}
prvtCfmLbrSeqNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Transaction identifier/Sequence number of the received LBR."
::= { prvtCfmLbrEntry 1 }
prvtCfmLbrReceiveOrder OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index to distinguish among multiple LBRs with the same LBR
Transaction Identifier field value. This situation can appear
in the case of multicast loopback."
::= { prvtCfmLbrEntry 2 }
prvtCfmLbrTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote MEPs response time in milliseconds."
::= { prvtCfmLbrEntry 3 }
prvtCfmLbrMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote MEPs mac address. For unicast loopback
this is the same as prvtCfmMepTransmitLbmDestMacAddress,
but for multicast loopback there will be different entries."
::= { prvtCfmLbrEntry 4 }
prvtCfmLbrBadMsdu OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Result of the Data TLV verification."
::= { prvtCfmLbrEntry 5 }
prvtCfmProfile OBJECT IDENTIFIER
::= { prvtCfmMIBObjects 7 }
prvtCfmProfileTableNextIndex OBJECT-TYPE
SYNTAX PrvtCfmIndexIntegerNextFree
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an unused value
for prvtCfmProfileIndex in the prvtCfmProfileTable
or a zero to indicate that none exist."
::= { prvtCfmProfile 1 }
prvtCfmProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table contains loopback results from all remote MEPs in the MA."
::= { prvtCfmProfile 2 }
prvtCfmProfileEntry OBJECT-TYPE
SYNTAX PrvtCfmProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in profile table"
INDEX { prvtCfmProfileIndex }
::= { prvtCfmProfileTable 1 }
PrvtCfmProfileEntry ::= SEQUENCE {
prvtCfmProfileIndex Unsigned32,
prvtCfmProfileRowStatus RowStatus,
prvtCfmProfileDescr OCTET STRING,
prvtCfmProfilePriority Unsigned32,
prvtCfmProfileRate Unsigned32,
prvtCfmProfileSize Unsigned32,
prvtCfmProfileBucketSize Unsigned32,
prvtCfmProfile1wJitterError Unsigned32,
prvtCfmProfile1wJitterWarning Unsigned32,
prvtCfmProfileJitterError Unsigned32,
prvtCfmProfileJitterErrorPeriod Unsigned32,
prvtCfmProfileJitterWarning Unsigned32,
prvtCfmProfileJitterWarningPeriod Unsigned32,
prvtCfmProfileFrameLossError Unsigned32,
prvtCfmProfileFrameLossWarning Unsigned32,
prvtCfmProfileLatencyError Unsigned32,
prvtCfmProfileLatencyErrorPeriod Unsigned32,
prvtCfmProfileLatencyWarning Unsigned32,
prvtCfmProfileLatencyWarningPeriod Unsigned32,
prvtCfmProfileOneWayJitterEnabled TruthValue,
prvtCfmProfileTwoWayJitterEnabled TruthValue,
prvtCfmProfileFramelossEnabled TruthValue,
prvtCfmProfileLatencyEnabled TruthValue
}
prvtCfmProfileIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table index."
::= { prvtCfmProfileEntry 1 }
prvtCfmProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns must have a valid value before a row
can be activated."
::= { prvtCfmProfileEntry 2 }
prvtCfmProfileDescr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A description for this profile.
This field must be unique among all profiles."
::= { prvtCfmProfileEntry 3 }
prvtCfmProfilePriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"802.1p class-of-service setting."
::= { prvtCfmProfileEntry 4 }
prvtCfmProfileRate OBJECT-TYPE
SYNTAX Unsigned32 (1..3)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of Request packets to send each time."
::= { prvtCfmProfileEntry 5 }
prvtCfmProfileSize OBJECT-TYPE
SYNTAX Unsigned32 (0..1462)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Size of data TLV included in probe packets (in octets)."
::= { prvtCfmProfileEntry 6 }
prvtCfmProfileBucketSize OBJECT-TYPE
SYNTAX Unsigned32 (2..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of the results to save for results calculation."
::= { prvtCfmProfileEntry 7 }
prvtCfmProfile1wJitterError OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies one-way jitter error values
to monitor in milliseconds."
::= { prvtCfmProfileEntry 8 }
prvtCfmProfile1wJitterWarning OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies one-way jitter warning values
to monitor in milliseconds."
::= { prvtCfmProfileEntry 9 }
prvtCfmProfileJitterError OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies round-trip jitter error values
to monitor in milliseconds."
::= { prvtCfmProfileEntry 10 }
prvtCfmProfileJitterErrorPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..3600)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the duration jitter occurs in seconds."
::= { prvtCfmProfileEntry 11 }
prvtCfmProfileJitterWarning OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies round-trip jitter warning values
to monitor in milliseconds. If set value is greater than the
jitter-error it means that the warning is disabled."
::= { prvtCfmProfileEntry 12 }
prvtCfmProfileJitterWarningPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..3600)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the duration jitter occurs in seconds."
::= { prvtCfmProfileEntry 13 }
prvtCfmProfileFrameLossError OBJECT-TYPE
SYNTAX Unsigned32 (0..99)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies round-trip frame-loss error
values to monitor. The default is
frame-loss of 10% is reported."
::= { prvtCfmProfileEntry 14 }
prvtCfmProfileFrameLossWarning OBJECT-TYPE
SYNTAX Unsigned32 (0..99)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies round-trip frame-loss warning
values to monitor. The default is frame-loss
of 8% is reported. If set value is greater
than the frame-loss-error it means
that the warning is disable."
::= { prvtCfmProfileEntry 15 }
prvtCfmProfileLatencyError OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies round-trip latency error values
to monitor in milliseconds."
::= { prvtCfmProfileEntry 16 }
prvtCfmProfileLatencyErrorPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..3600)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the duration latency increase
occurs in seconds."
::= { prvtCfmProfileEntry 17 }
prvtCfmProfileLatencyWarning OBJECT-TYPE
SYNTAX Unsigned32 (1..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies round-trip latency error
values to monitor in milliseconds.
If set value is greater than the
latency-error it means that the
warning is disabled."
::= { prvtCfmProfileEntry 18 }
prvtCfmProfileLatencyWarningPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..3600)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the duration latency increase occurs."
::= { prvtCfmProfileEntry 19 }
prvtCfmProfileOneWayJitterEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify if one-way jitter is monitored."
::= { prvtCfmProfileEntry 20 }
prvtCfmProfileTwoWayJitterEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify if two-way jitter is monitored."
::= { prvtCfmProfileEntry 21 }
prvtCfmProfileFramelossEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify if frame-loss is monitored."
::= { prvtCfmProfileEntry 22 }
prvtCfmProfileLatencyEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify if two-way latency is monitored."
::= { prvtCfmProfileEntry 23 }
prvtCfmProcess OBJECT IDENTIFIER
::= { prvtCfmMIBObjects 8 }
prvtCfmProcessTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Private extension of prvtCfmMaTable.
Controls the two-way monitoring process
for MEP's in the MA."
::= { prvtCfmProcess 1 }
prvtCfmProcessEntry OBJECT-TYPE
SYNTAX PrvtCfmProcessEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCfmProcessEntry"
INDEX { prvtCfmProcessIndex, prvtCfmMdName, prvtCfmMaName }
::= { prvtCfmProcessTable 1 }
PrvtCfmProcessEntry ::= SEQUENCE {
prvtCfmProcessIndex Unsigned32,
prvtCfmProcessRowStatus RowStatus,
prvtCfmProcessProfileIndex Unsigned32,
prvtCfmProcessName OCTET STRING,
prvtCfmProcessShutdown TruthValue,
prvtCfmProcessRepeatInterval Unsigned32,
prvtCfmProcessPacketType INTEGER,
prvtCfmProcessUnreturnedPkts Unsigned32
}
prvtCfmProcessIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table index."
::= { prvtCfmProcessEntry 1 }
prvtCfmProcessRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row can not be
changed if the row is active. All columns
must have a valid value before a row can
be activated."
::= { prvtCfmProcessEntry 2 }
prvtCfmProcessProfileIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..64)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index of the monitoring profile to be used."
::= { prvtCfmProcessEntry 3 }
prvtCfmProcessName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the process. Should be unique per domain/MA"
::= { prvtCfmProcessEntry 4 }
prvtCfmProcessShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value 'true' will disable two-way monitoring process
for MEP's in the MA."
::= { prvtCfmProcessEntry 5 }
prvtCfmProcessRepeatInterval OBJECT-TYPE
SYNTAX Unsigned32 (1..420)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Repeating frequency of the monitoring process."
::= { prvtCfmProcessEntry 6 }
prvtCfmProcessPacketType OBJECT-TYPE
SYNTAX INTEGER { cfm(1), y1731(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Use CFM Loopback or Y.1731 LMMs and DMMs packets."
::= { prvtCfmProcessEntry 7 }
prvtCfmProcessUnreturnedPkts OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of requests for which a reply
hasn't been received. These packets
will be counted as lost when they
enter timeout."
::= { prvtCfmProcessEntry 8 }
prvtCfmProcessResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmProcessResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table contains process results."
::= { prvtCfmProcess 2 }
prvtCfmProcessResultEntry OBJECT-TYPE
SYNTAX PrvtCfmProcessResultEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCfmProcessResultEntry"
INDEX { prvtCfmMdName, prvtCfmMaName, prvtCfmProcessIndex,
prvtCfmMepDbRMepIdentifier }
::= { prvtCfmProcessResultTable 1 }
PrvtCfmProcessResultEntry ::= SEQUENCE {
prvtCfmProcessResultOneWayJitter Unsigned32,
prvtCfmProcessResultTwoWayJitter Unsigned32,
prvtCfmProcessResultLatency Unsigned32,
prvtCfmProcessResultFrameloss Unsigned32
}
prvtCfmProcessResultOneWayJitter OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One way jitter calculated for
a specific remote MEP in milliseconds"
::= { prvtCfmProcessResultEntry 1 }
prvtCfmProcessResultTwoWayJitter OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Two way jitter calculated for a specific
remote MEP in milliseconds"
::= { prvtCfmProcessResultEntry 2 }
prvtCfmProcessResultLatency OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Two way latency calculated for a specific
remote MEP in milliseconds"
::= { prvtCfmProcessResultEntry 3 }
prvtCfmProcessResultFrameloss OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Two way frameloss calculated for a specific
remote MEP in units of hundredths of percent.
Note: When prvtCfmProcessResultFrameloss has
value of 10000, all the values of
prvtCfmProcessResultOneWayJitter,
prvtCfmProcessResultTwoWayJitter and
prvtCfmProcessResultLatency are irrelevant."
::= { prvtCfmProcessResultEntry 4 }
prvtCfmMaAisLckVlan OBJECT IDENTIFIER
::= { prvtCfmMIBObjects 9 }
prvtCfmMaAisLckVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCfmMaAisLckVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table includes extra variables needed for AIS/LCK configurable vlans"
::= { prvtCfmMaAisLckVlan 1 }
prvtCfmMaAisLckVlanEntry OBJECT-TYPE
SYNTAX PrvtCfmMaAisLckVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table includes extra variables needed for AIS/LCK configurable vlans"
INDEX { prvtCfmMdName, prvtCfmMaName, prvtCfmMaAisLckVlanId }
::= { prvtCfmMaAisLckVlanTable 1 }
PrvtCfmMaAisLckVlanEntry ::= SEQUENCE {
prvtCfmMaAisLckVlanId Integer32,
prvtCfmMaAisLckVlanRowStatus RowStatus
}
prvtCfmMaAisLckVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Vlan ID (towards customer level) that the generated AIS/LCK packets should use."
::= { prvtCfmMaAisLckVlanEntry 1 }
prvtCfmMaAisLckVlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row."
::= { prvtCfmMaAisLckVlanEntry 2 }
prvtCfm1wJitterThreshold NOTIFICATION-TYPE
OBJECTS { prvtCfmProcessResultOneWayJitter,
prvtCfmProfile1wJitterWarning,
prvtCfmProfile1wJitterError }
STATUS current
DESCRIPTION
"This trap should be sent whenever the one way jitter
on a CFM test will surpass one of the 2 defined thresholds."
::= { prvtCfmMIBNotifications 1 }
prvtCfmJitterThreshold NOTIFICATION-TYPE
OBJECTS { prvtCfmProcessResultTwoWayJitter,
prvtCfmProfileJitterWarning,
prvtCfmProfileJitterWarningPeriod,
prvtCfmProfileJitterError,
prvtCfmProfileJitterErrorPeriod }
STATUS current
DESCRIPTION
"This trap should be sent whenever the two way jitter
on a CFM test will surpass one of the 2 defined thresholds."
::= { prvtCfmMIBNotifications 2 }
prvtCfmFrameLossThreshold NOTIFICATION-TYPE
OBJECTS { prvtCfmProcessResultFrameloss,
prvtCfmProfileFrameLossWarning,
prvtCfmProfileFrameLossError }
STATUS current
DESCRIPTION
"This trap should be sent whenever the frame loss
on a CFM test will surpass one of the 2 defined
thresholds."
::= { prvtCfmMIBNotifications 3 }
prvtCfmLatencyThreshold NOTIFICATION-TYPE
OBJECTS { prvtCfmProcessResultLatency,
prvtCfmProfileLatencyWarning,
prvtCfmProfileLatencyWarningPeriod,
prvtCfmProfileLatencyError,
prvtCfmProfileLatencyErrorPeriod }
STATUS current
DESCRIPTION
"This trap should be sent whenever the latency
on a CFM test will surpass one of the 2 defined
thresholds."
::= { prvtCfmMIBNotifications 4 }
prvtCfmUnexpectedPriority NOTIFICATION-TYPE
OBJECTS { prvtCfmMepDirection, prvtCfmMepDbMacAddress,
prvtCfmMepInterfaceIndex }
STATUS current
DESCRIPTION
"References to in the [G.8021/Y.1341] :
Unexpected Priority defect (dUNPr)
The Unexpected Priority defect is calculated at the ETH layer.
It detects the configuration of different Priorities
for CCM at different MEPs belonging to the same MEG."
::= { prvtCfmMIBNotifications 5 }
prvtCfmFaultAlarm NOTIFICATION-TYPE
OBJECTS { prvtCfmMepDirection, prvtCfmMepHighestPrDefect,
prvtCfmMepInterfaceIndex }
STATUS current
DESCRIPTION
"A MEP has a persistent defect condition. A notification
(fault alarm) is sent to the management entity with the OID
of the MEP that has detected the fault.
Whenever a MEP has a persistent defect,
it may or may not generate a Fault Alarm to warn the system
administrator of the problem, as controlled by the MEP
Fault Notification Generator State Machine and associated
Managed Objects. Only the highest-priority defect, as shown
in Table 20-1, is reported in the Fault Alarm.
If a defect with a higher priority is raised after a Fault
Alarm has been issued, another Fault Alarm is issued.
The management entity receiving the notification can identify
the system from the network source address of the
notification, and can identify the MEP reporting the defect
by the indices in the OID of the prvtCfmMepHighestPrDefect
variable in the notification:
prvtCfmMdName - Also the index of the MEP's
Maintenance Domain table entry
(prvtCfmMdTable).
prvtCfmMaName - Also an index (with the MD table index)
of the MEP's Maintenance Association
table entry
(prvtCfmMaTable),
prvtCfmMepIdentifier - MEP Identifier and final index
into the MEP table (prvtCfmMepTable)."
REFERENCE
"802.1ag clause 12.14.7.7"
::= { prvtCfmMIBNotifications 6 }
prvtCfmAisLckRecieved NOTIFICATION-TYPE
OBJECTS { prvtCfmMepAisCondition }
STATUS current
DESCRIPTION
"A MEP may generate a AIS/LCK notification each time its
AIS/LCK condition is activated."
REFERENCE
"ITU-T Recommendation Y.1731 APPENDIX I Defect Conditions
I.7 AIS Condition, I.9 LCK Condition"
::= { prvtCfmMIBNotifications 7 }
prvtCfmAisLckCleared NOTIFICATION-TYPE
OBJECTS { prvtCfmMepAisCondition }
STATUS current
DESCRIPTION
"The notification is sent each time
AIS/LCK condition is cleared."
REFERENCE
"ITU-T Recommendation Y.1731 APPENDIX I Defect Conditions
I.7 AIS Condition, I.9 LCK Condition"
::= { prvtCfmMIBNotifications 8 }
prvtCfmFaultAlarmCleared NOTIFICATION-TYPE
OBJECTS { prvtCfmMepDirection, prvtCfmMepFngState }
STATUS current
DESCRIPTION
"A MEP's persistent defect condition has cleared. A notification
is sent to the management entity with the OID
of the MEP that has cleared the fault.
The management entity receiving the notification can identify
the system from the network source address of the
notification, and can identify the MEP by the indices in the
OID of the prvtCfmMepIdentifier variable in the notification:
prvtCfmMdName - Also the index of the MEP's
Maintenance Domain table entry
(prvtCfmMdTable).
prvtCfmMaName - Also an index (with the MD table index)
of the MEP's Maintenance Association
table entry
(prvtCfmMaTable),
prvtCfmMepIdentifier - MEP Identifier and final index
into the MEP table (prvtCfmMepTable)."
::= { prvtCfmMIBNotifications 9 }
END -- end of module PRVT-CFM-MIB.