mibs/MIBS/tplink/TPLINK-DDMBIASCURTHRESHOLD-MIB

99 lines
3.3 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
TPLINK-DDMBIASCURTHRESHOLD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE
FROM SNMPv2-SMI
ifIndex
FROM RFC1213-MIB
DisplayString
FROM SNMPv2-TC
tplinkDdmManageMIBObjects
FROM TPLINK-DDMMANAGE-MIB;
ddmBiasCurThreshold MODULE-IDENTITY
LAST-UPDATED "200908270000Z"
ORGANIZATION "TPLINK"
CONTACT-INFO "www.tplink.com"
DESCRIPTION "The config of DDM bias current threshold."
REVISION "200908270000Z"
DESCRIPTION "Initial version of this MIB module."
::= { tplinkDdmManageMIBObjects 4 }
ddmBiasCurThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF DDMBiasCurThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that is used to configure the DDM Bias Current Threshold for specific ports on the Switch."
::= { ddmBiasCurThreshold 1 }
ddmBiasCurThresholdEntry OBJECT-TYPE
SYNTAX DDMBiasCurThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information for every port."
INDEX { ifIndex }
::= { ddmBiasCurThresholdTable 1 }
DDMBiasCurThresholdEntry ::=
SEQUENCE
{
ddmBiasCurThresholdPort DisplayString(SIZE(0..255)),
ddmBiasCurThresholdHighAlarm OCTET STRING(SIZE(0..30)),
ddmBiasCurThresholdLowAlarm OCTET STRING(SIZE(0..30)),
ddmBiasCurThresholdHighWarn OCTET STRING(SIZE(0..30)),
ddmBiasCurThresholdLowWarn OCTET STRING(SIZE(0..30)),
ddmBiasCurThresholdPortLAG OCTET STRING(SIZE(0..30))
}
ddmBiasCurThresholdPort OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the port number."
::= { ddmBiasCurThresholdEntry 1 }
ddmBiasCurThresholdHighAlarm OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..30))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the highest threshold for the alarm."
::= { ddmBiasCurThresholdEntry 2 }
ddmBiasCurThresholdLowAlarm OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..30))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the lowest threshold for the alarm."
::= { ddmBiasCurThresholdEntry 3 }
ddmBiasCurThresholdHighWarn OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..30))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the highest threshold for the warning."
::= { ddmBiasCurThresholdEntry 4 }
ddmBiasCurThresholdLowWarn OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..30))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the lowest threshold for the warning."
::= { ddmBiasCurThresholdEntry 5 }
ddmBiasCurThresholdPortLAG OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the lag number of the port."
::= { ddmBiasCurThresholdEntry 6 }
END