mibs/MIBS/transition/TN-CES-MIB

2770 lines
88 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- *****************************************************************
-- Transition Networks CES MIB
--
-- Copyright (C) 2013 Transition Networks, Inc. All Rights Reserved.
-- *****************************************************************
-- ---------------------------------------------------------- --
-- MIB for the Circuit Emulation Service (CES) features of
-- Transition Networks products.
-- ---------------------------------------------------------- --
TN-CES-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Counter32,
Integer32 FROM SNMPv2-SMI
InetAddressType, InetAddress FROM INET-ADDRESS-MIB
TruthValue, MacAddress, DisplayString, DateAndTime FROM SNMPv2-TC
OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF
tnProducts FROM TRANSITION-SMI;
tnCesMIB MODULE-IDENTITY
LAST-UPDATED "201511250000Z"
ORGANIZATION "Transition Networks, Inc."
CONTACT-INFO
"Transition Networks
Technical Support
10900 Red Circle Drive
Minnetonka, MN 55343 USA
Tel: +1-800-526-9267
E-mail: techsupport@transition.com"
DESCRIPTION
"The MIB module for the Circuit Emulation Service."
REVISION "201511250000Z"
DESCRIPTION
"Initial version."
::= { tnProducts 60 }
-- Top level structure
tnCesNotifications OBJECT IDENTIFIER ::= { tnCesMIB 0 }
tnCesEventId OBJECT IDENTIFIER ::= { tnCesNotifications 3 }
tnCesEventIdGeneral OBJECT IDENTIFIER ::= { tnCesEventId 0 }
tnCesObjects OBJECT IDENTIFIER ::= { tnCesMIB 1 }
tnCesConformance OBJECT IDENTIFIER ::= { tnCesMIB 2 }
tnCesCompliances OBJECT IDENTIFIER ::= { tnCesConformance 1 }
tnCesGroups OBJECT IDENTIFIER ::= { tnCesConformance 2 }
-- Protocol configuration.
tnCesProtocol OBJECT IDENTIFIER ::= { tnCesObjects 1 }
tnCesProtocolType OBJECT-TYPE
SYNTAX INTEGER {
ipUdpRtp (0),
ip (1),
mpls (2),
ethernet (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which network protocol to use for TDM over IP packets. Note that MPLS is not currenly supported."
::= { tnCesProtocol 1 }
tnCesProtocolUnderrunFixed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determins the underrun value in a TDM timeslot when no data was available in the logical link jitter buffer. When true, use the fixed value specified by tnCesProtocolUnderrunValue. When false, use the last value sent on the timeslot."
::= { tnCesProtocol 2 }
tnCesProtocolUnderrunValue OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determins the underrun value in a TDM timeslot when no data was available in the logical link jitter buffer. Used when tnCesProtocolUnderrunFixed is false."
::= { tnCesProtocol 3 }
tnCesProtocolUDPBasePort OBJECT-TYPE
SYNTAX Unsigned32 (0..65472)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for the first logical link. The 2nd logical link uses this value plus one, and so on. Only relevent when tnCesProtocolType is ipUdpRtp."
::= { tnCesProtocol 4 }
tnCesProtocolEnableSSRCChecking OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether to check the RTP SSRC value on received packets. Disabling the check can be useful in aiding compatibility with equipment from other vendors. Only used when tnCesProtocolType is ipUdpRtp."
::= { tnCesProtocol 5 }
-- Alternate clock architecture global configuration.
tnCesClockingAlternate OBJECT IDENTIFIER ::= { tnCesObjects 2 }
tnCesClockingAlternateEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether to use the alternate clocking architecure which supports asymmeric and plesiosynchronous operation."
::= { tnCesClockingAlternate 1 }
-- Clock recovery configuration.
tnCesClockRecovery OBJECT IDENTIFIER ::= { tnCesObjects 3 }
tnCesClockRecoveryAlgorithm OBJECT-TYPE
SYNTAX INTEGER {
adaptive (1),
adaptiveEnhanced (2),
adaptiveFrequency (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which algorithm to use for TDM over IP clock recovery."
::= { tnCesClockRecovery 1 }
tnCesClockRecoveryFilter OBJECT-TYPE
SYNTAX INTEGER {
type1 (1),
type2 (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Which filter setting to use for TDM over IP clock recovery."
::= { tnCesClockRecovery 2 }
tnCesClockRecoveryMaxDeviation OBJECT-TYPE
SYNTAX Unsigned32 (5..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum step change allowed in the recovered clock in PPM."
::= { tnCesClockRecovery 3 }
-- Event reporting configuration.
tnCesEvent OBJECT IDENTIFIER ::= { tnCesObjects 4 }
tnCesEventThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority threshold for reporting events related to CES. Events with a priority above this level are not reported to the system log or notified in SNMP traps."
::= { tnCesEvent 1 }
tnCesEventReportingInterval OBJECT-TYPE
SYNTAX Unsigned32 (1..1440)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How frequently to report certain CES events when thesholds are exceeded. The interval is specicifed in minutes."
::= { tnCesEvent 2 }
tnCesEventThresholdEarly OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold above which to report early packet errors. When this value is zero, reporting is disabled."
::= { tnCesEvent 3 }
tnCesEventThresholdLate OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold above which to report late packet errors. When this value is zero, reporting is disabled."
::= { tnCesEvent 4 }
tnCesEventThresholdUnderrun OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold above which to report underrun errors. When this value is zero, reporting is disabled."
::= { tnCesEvent 5 }
tnCesEventThresholdDCO OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold above which to report clock recovery DCO changes. When this value is zero, reporting is disabled."
::= { tnCesEvent 6 }
-- Packet Processor status.
tnCesProcessor OBJECT IDENTIFIER ::= { tnCesObjects 5 }
tnCesProcessorVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CES packet processor hardware and software version information."
::= { tnCesProcessor 1 }
tnCesProcessorProtocolMatch1 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames which hit protocol matching rule 1."
::= { tnCesProcessor 2 }
tnCesProcessorProtocolMatch2 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames which hit protocol matching rule 2."
::= { tnCesProcessor 3 }
tnCesProcessorProtocolMatch3 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames which hit protocol matching rule 3."
::= { tnCesProcessor 4 }
tnCesProcessorProtocolMatch4 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames which hit protocol matching rule 4."
::= { tnCesProcessor 5 }
tnCesProcessorProtocolNoMatch OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames which hit no protocol matching rules."
::= { tnCesProcessor 6 }
tnCesProcessorClassifyFail OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames which fail to classify."
::= { tnCesProcessor 7 }
tnCesProcessorVerifyFail OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames which fail to verify."
::= { tnCesProcessor 8 }
tnCesProcessorIpv4ChecksumFail OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames with IPV4 checksum failures."
::= { tnCesProcessor 9 }
tnCesProcessorUdpChecksumFail OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames with UDP checksum failures."
::= { tnCesProcessor 10 }
-- Global clocking status.
tnCesClockStatus OBJECT IDENTIFIER ::= { tnCesObjects 6 }
tnCesClockStatusLock OBJECT-TYPE
SYNTAX INTEGER {
clockLockAutomatic (0),
clockLockNormal (1),
clockLockHoldover (2),
clockLockFreerun (3),
clockLockUnknown (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CES processor DPLL lock status."
::= { tnCesClockStatus 1 }
tnCesClockStatusSlaveMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether the CES processor clock is in slave (true) or master (false) mode."
::= { tnCesClockStatus 2 }
tnCesClockStatusSource OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the current clock source."
::= { tnCesClockStatus 3 }
-- Temperature status.
tnCesTemperature OBJECT IDENTIFIER ::= { tnCesObjects 7 }
tnCesTemperatureBoardWhole OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature measurement of circuit board. Whole part before the decimal point."
::= { tnCesTemperature 1 }
tnCesTemperatureBoardFrac OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature measurement of circuit board. Fractional part after the decimal point."
::= { tnCesTemperature 2 }
tnCesTemperatureProcessorWhole OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature measurement of processor. Whole part before the decimal point."
::= { tnCesTemperature 3 }
tnCesTemperatureProcessorFrac OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature measurement of processor. Fractional part after the decimal point."
::= { tnCesTemperature 4 }
-- IP address configuration.
tnCesIP OBJECT IDENTIFIER ::= { tnCesObjects 8 }
tnCesIpv4AddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address type associated with tnCesIpv4Addr. Has the value ipv4."
::= { tnCesIP 1 }
tnCesIpv4Addr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv4 address to use for TDM over IP packets. Applies when the remote end of a circuit has an IPv4 address."
::= { tnCesIP 2 }
tnCesIpv4PrefixLength OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The prefix length associated with the CES IPv4 address."
::= { tnCesIP 3 }
tnCesIpv6AddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address type associated with tnCesIpv6Addr. Has the value ipv6."
::= { tnCesIP 4 }
tnCesIpv6Addr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 address to use for TDM over IP packets. Applies when the remote end of a circuit has an IPv6 address."
::= { tnCesIP 5 }
tnCesIpv6PrefixLength OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The prefix length associated with the CES IPv6 address."
::= { tnCesIP 6 }
-- Clock priority configuration.
tnCesClockPriority OBJECT IDENTIFIER ::= { tnCesObjects 9 }
tnCesMiscClockPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesMiscClockPriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of clock priorities for miscellaneous sources."
::= { tnCesClockPriority 1 }
tnCesMiscClockPriorityEntry OBJECT-TYPE
SYNTAX TnCesMiscClockPriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the clock priority for a particular clock source."
INDEX { tnCesMiscClockPriorityItem }
::= { tnCesMiscClockPriorityTable 1 }
TnCesMiscClockPriorityEntry ::= SEQUENCE {
tnCesMiscClockPriorityItem INTEGER,
tnCesMiscClockPriority Unsigned32
}
tnCesMiscClockPriorityItem OBJECT-TYPE
SYNTAX INTEGER {
internal (1)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Which clock source this clock priority is for."
::= { tnCesMiscClockPriorityEntry 1 }
tnCesMiscClockPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..19)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The clock priority of a clock source. A lower numeric value indicates a higher priority."
::= { tnCesMiscClockPriorityEntry 2 }
tnCesPRIClockPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesPRIClockPriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of clock priorities for TDM ports."
::= { tnCesClockPriority 2 }
tnCesPRIClockPriorityEntry OBJECT-TYPE
SYNTAX TnCesPRIClockPriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the clock priority for a TDM port."
INDEX { tnCesPRIClockPriorityIndex }
::= { tnCesPRIClockPriorityTable 1 }
TnCesPRIClockPriorityEntry ::= SEQUENCE {
tnCesPRIClockPriorityIndex Unsigned32,
tnCesPRIClockPriority Unsigned32
}
tnCesPRIClockPriorityIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Which TDM port this clock priority is for."
::= { tnCesPRIClockPriorityEntry 1 }
tnCesPRIClockPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..19)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The clock priority of a TDM port. A lower numeric value indicates a higher priority."
::= { tnCesPRIClockPriorityEntry 2 }
tnCesLLClockPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesLLClockPriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of clock priorities for logical link clock streams."
::= { tnCesClockPriority 3 }
tnCesLLClockPriorityEntry OBJECT-TYPE
SYNTAX TnCesLLClockPriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the clock priority for a logical link clock stream."
INDEX { tnCesLLClockPriorityIndex }
::= { tnCesLLClockPriorityTable 1 }
TnCesLLClockPriorityEntry ::= SEQUENCE {
tnCesLLClockPriorityIndex Unsigned32,
tnCesLLClockPriority Unsigned32
}
tnCesLLClockPriorityIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Which logical link clocking stream this clock priority is for."
::= { tnCesLLClockPriorityEntry 1 }
tnCesLLClockPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..19)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The clock priority of a logical link clock stream. A lower numeric value indicates a higher priority."
::= { tnCesLLClockPriorityEntry 2 }
-- Multicast join configuration.
tnCesMulticastJoinTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesMulticastJoinEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of multicast groups to join."
::= { tnCesObjects 10 }
tnCesMulticastJoinEntry OBJECT-TYPE
SYNTAX TnCesMulticastJoinEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the configuration for a multicast group to join."
INDEX { tnCesMulticastJoinIndex }
::= { tnCesMulticastJoinTable 1 }
TnCesMulticastJoinEntry ::= SEQUENCE {
tnCesMulticastJoinIndex Unsigned32,
tnCesMulticastJoinAction TruthValue,
tnCesMulticastJoinAddrType InetAddressType,
tnCesMulticastJoinAddr InetAddress
}
tnCesMulticastJoinIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of multicast group."
::= { tnCesMulticastJoinEntry 1 }
tnCesMulticastJoinAction OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether to join a multicast group. When true, join the group specified by tnCesMulticastJoinAddr. When false, do not join any group and leave any previously joined goup."
::= { tnCesMulticastJoinEntry 2 }
tnCesMulticastJoinAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address type of the multicast group to join. Must be ipv4 or ipv6."
::= { tnCesMulticastJoinEntry 3 }
tnCesMulticastJoinAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the multicast group to join. This must be a multicast address."
::= { tnCesMulticastJoinEntry 4 }
-- TDM port configuration.
tnCesTDMTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesTDMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of TDM ports."
::= { tnCesObjects 11 }
tnCesTDMEntry OBJECT-TYPE
SYNTAX TnCesTDMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the configuration for a TDM port."
INDEX { tnCesTDMPortNumber }
::= { tnCesTDMTable 1 }
TnCesTDMEntry ::= SEQUENCE {
tnCesTDMPortNumber Unsigned32,
tnCesTDMPresentation INTEGER,
tnCesTDMFraming INTEGER,
tnCesTDMMode INTEGER,
tnCesTDMTS0Passthrough TruthValue,
tnCesTDMCRC4 TruthValue,
tnCesTDMShutdownCallsOnFail TruthValue,
tnCesTDMImpedance INTEGER,
tnCesTDMT1Framing INTEGER,
tnCesTDMT1LineCode INTEGER,
tnCesTDMT1LoopCodeType INTEGER,
tnCesTDMT1LoopCodeRxEnable TruthValue,
tnCesTDMT1LoopCodeUserUp Unsigned32,
tnCesTDMT1LoopCodeUserDown Unsigned32,
tnCesTDMT1LoopCodeUserLength Unsigned32,
tnCesTDMDTE TruthValue
}
tnCesTDMPortNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The TDM port number."
::= { tnCesTDMEntry 1 }
tnCesTDMPresentation OBJECT-TYPE
SYNTAX INTEGER {
te (0),
nt (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Network or user presentation. This options is not supported on all products. Modifications will be ignore on such products."
::= { tnCesTDMEntry 2 }
tnCesTDMFraming OBJECT-TYPE
SYNTAX INTEGER {
full (0),
fractional (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether the TDM port operates in framed fractional or unframed full mode. It is not possible to set a port mode which would exclude any TDM channels that are assigned to a logical link (see tnCesLLChanSelectUsed). Any such channel must be deassigned first."
::= { tnCesTDMEntry 3 }
tnCesTDMMode OBJECT-TYPE
SYNTAX INTEGER {
e1 (0),
t1 (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TDM port mode T1 or E1. It is not possible to set a port mode which would exclude any TDM channels that are assigned to a logical link (see tnCesLLChanSelectUsed). Any such channel must be deassigned first."
::= { tnCesTDMEntry 4 }
tnCesTDMTS0Passthrough OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether timeslot zero is passed in E1 fractional mode. Only valid when tnCesTDMFraming is fractional and tnCesTDMMode is E1."
::= { tnCesTDMEntry 5 }
tnCesTDMCRC4 OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether the TDM framing uses CRC4. Only valid when tnCesTDMFraming is fractional."
::= { tnCesTDMEntry 6 }
tnCesTDMShutdownCallsOnFail OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether to shutdown the CES connections or ISDN calls using this port when the port fails."
::= { tnCesTDMEntry 7 }
tnCesTDMImpedance OBJECT-TYPE
SYNTAX INTEGER {
impedance120ohms (0),
impedance75ohms (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Electrical impedance of the TDM port, 75ohms or 120ohms."
::= { tnCesTDMEntry 8 }
tnCesTDMT1Framing OBJECT-TYPE
SYNTAX INTEGER {
esf (0),
d4 (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The frame structure in T1 mode. Only used when tnCesTDMMode is T1."
::= { tnCesTDMEntry 9 }
tnCesTDMT1LineCode OBJECT-TYPE
SYNTAX INTEGER {
b8zs (0),
ami (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The line code in T1 mode. Only used when tnCesTDMMode is T1."
::= { tnCesTDMEntry 10 }
tnCesTDMT1LoopCodeType OBJECT-TYPE
SYNTAX INTEGER {
fac1 (0),
fac2 (1),
fac3 (2),
user (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of loop code which when detected on the port will cause loops to be switched on or off."
::= { tnCesTDMEntry 11 }
tnCesTDMT1LoopCodeRxEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether detection of loop codes is enabled or disabled on the port."
::= { tnCesTDMEntry 12 }
tnCesTDMT1LoopCodeUserUp OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User defined bit pattern to cause loop up for the FACU option."
::= { tnCesTDMEntry 13 }
tnCesTDMT1LoopCodeUserDown OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User defined bit pattern to cause loop down for the FACU option."
::= { tnCesTDMEntry 14 }
tnCesTDMT1LoopCodeUserLength OBJECT-TYPE
SYNTAX Unsigned32 (4..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of bits in tnCesTDMT1LoopCodeUserUp and tnCesTDMT1LoopCodeUserDown."
::= { tnCesTDMEntry 15 }
tnCesTDMDTE OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether the port is configured as DTE (true) or DCE (false). Only applies to Contra ports."
::= { tnCesTDMEntry 16 }
-- Logical link configuration.
tnCesLLTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesLLEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of logical link configuration."
::= { tnCesObjects 12 }
tnCesLLEntry OBJECT-TYPE
SYNTAX TnCesLLEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the current configuration of a logical link."
INDEX { tnCesLLNumber }
::= { tnCesLLTable 1 }
TnCesLLEntry ::= SEQUENCE {
tnCesLLNumber Unsigned32,
tnCesLLname DisplayString,
tnCesLLDirection INTEGER,
tnCesLLRemoteIpAddrType InetAddressType,
tnCesLLRemoteIpAddr InetAddress,
tnCesLLSecondaryRemoteIpAddrType InetAddressType,
tnCesLLSecondaryRemoteIpAddr InetAddress,
tnCesLLQosType INTEGER,
tnCesLLQosTOS Unsigned32,
tnCesLLQosDiffserv Unsigned32,
tnCesLLVlanTag TruthValue,
tnCesLLVlanId Unsigned32,
tnCesLLVlanPriority Unsigned32,
tnCesLLJitterBufferLength Unsigned32,
tnCesLLFramesPerPacket Unsigned32,
tnCesLLRemoteLinkNumber Unsigned32
}
tnCesLLNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..128)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The logical link number."
::= { tnCesLLEntry 1 }
tnCesLLname OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An optional name for the logical link."
::= { tnCesLLEntry 2 }
tnCesLLDirection OBJECT-TYPE
SYNTAX INTEGER {
disable (0),
rx (1),
tx (2),
both (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Direction of data flow over the packet network for a logical link."
::= { tnCesLLEntry 3 }
tnCesLLRemoteIpAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address type of the remote end of the logical link. Must be ipv4 or ipv6."
::= { tnCesLLEntry 4 }
tnCesLLRemoteIpAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the remote end of the logical link. If tnCesLLDirection is tx or both then this may be a unicast or multicast address. If tnCesLLDirection is rx then this must be a unicast address."
::= { tnCesLLEntry 5 }
tnCesLLSecondaryRemoteIpAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The secondary IP address type of the remote end of the logical link. Must be ipv4 or ipv6."
::= { tnCesLLEntry 6 }
tnCesLLSecondaryRemoteIpAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The secondary IP address of the remote end of the logical link. If tnCesLLDirection is tx or both then this may be a unicast or multicast address. If tnCesLLDirection is rx then this must be a unicast address."
::= { tnCesLLEntry 7 }
tnCesLLQosType OBJECT-TYPE
SYNTAX INTEGER {
tos (0),
diffserv (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether logical link QOS is encoded as Type of Service (TOS) or Diffserv."
::= { tnCesLLEntry 8 }
tnCesLLQosTOS OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Type Of Service value for logical link QOS. Only used when tnCesLLQosType is tos."
::= { tnCesLLEntry 9 }
tnCesLLQosDiffserv OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Diffserv codepoint value for logical link QOS. Only used when tnCesLLQosType is diffserv."
::= { tnCesLLEntry 10 }
tnCesLLVlanTag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether Ethernet frames for this logical link are VLAN tagged."
::= { tnCesLLEntry 11 }
tnCesLLVlanId OBJECT-TYPE
SYNTAX Unsigned32 (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID for Ethernet frames for this logical link. Only applies when tnCesLLVlanTag is true."
::= { tnCesLLEntry 12 }
tnCesLLVlanPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priority value for Ethernet frames for this logical link. Only applies when tnCesLLVlanTag is true."
::= { tnCesLLEntry 13 }
tnCesLLJitterBufferLength OBJECT-TYPE
SYNTAX Unsigned32 (1..400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Jitter buffer length in ms for this logical link."
::= { tnCesLLEntry 14 }
tnCesLLFramesPerPacket OBJECT-TYPE
SYNTAX Unsigned32 (1..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In framed mode, the number of TDM frames in the packet payload for this logical link."
::= { tnCesLLEntry 15 }
tnCesLLRemoteLinkNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The remote logical link number that this link exchanges packets with."
::= { tnCesLLEntry 16 }
-- Logical link schedule configuration.
tnCesLLSchedTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesLLSchedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of logical link schedule configuration."
::= { tnCesObjects 13 }
tnCesLLSchedEntry OBJECT-TYPE
SYNTAX TnCesLLSchedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the current configuration of a logical link schedule."
INDEX { tnCesLLSchedNumber }
::= { tnCesLLSchedTable 1 }
TnCesLLSchedEntry ::= SEQUENCE {
tnCesLLSchedNumber Unsigned32,
tnCesLLSchedEnable TruthValue,
tnCesLLSchedStartTimeMonHours Unsigned32,
tnCesLLSchedStartTimeMonMins Unsigned32,
tnCesLLSchedStopTimeMonHours Unsigned32,
tnCesLLSchedStopTimeMonMins Unsigned32,
tnCesLLSchedStartTimeTueHours Unsigned32,
tnCesLLSchedStartTimeTueMins Unsigned32,
tnCesLLSchedStopTimeTueHours Unsigned32,
tnCesLLSchedStopTimeTueMins Unsigned32,
tnCesLLSchedStartTimeWedHours Unsigned32,
tnCesLLSchedStartTimeWedMins Unsigned32,
tnCesLLSchedStopTimeWedHours Unsigned32,
tnCesLLSchedStopTimeWedMins Unsigned32,
tnCesLLSchedStartTimeThuHours Unsigned32,
tnCesLLSchedStartTimeThuMins Unsigned32,
tnCesLLSchedStopTimeThuHours Unsigned32,
tnCesLLSchedStopTimeThuMins Unsigned32,
tnCesLLSchedStartTimeFriHours Unsigned32,
tnCesLLSchedStartTimeFriMins Unsigned32,
tnCesLLSchedStopTimeFriHours Unsigned32,
tnCesLLSchedStopTimeFriMins Unsigned32,
tnCesLLSchedStartTimeSatHours Unsigned32,
tnCesLLSchedStartTimeSatMins Unsigned32,
tnCesLLSchedStopTimeSatHours Unsigned32,
tnCesLLSchedStopTimeSatMins Unsigned32,
tnCesLLSchedStartTimeSunHours Unsigned32,
tnCesLLSchedStartTimeSunMins Unsigned32,
tnCesLLSchedStopTimeSunHours Unsigned32,
tnCesLLSchedStopTimeSunMins Unsigned32
}
tnCesLLSchedNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..128)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The logical link number."
::= { tnCesLLSchedEntry 1 }
tnCesLLSchedEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether to enable the logical link schedule. When false, there is no scheduling and this link is always on. When true, the link is enabled according to its schedule."
::= { tnCesLLSchedEntry 2 }
tnCesLLSchedStartTimeMonHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 3 }
tnCesLLSchedStartTimeMonMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 4 }
tnCesLLSchedStopTimeMonHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 5 }
tnCesLLSchedStopTimeMonMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 6 }
tnCesLLSchedStartTimeTueHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 7 }
tnCesLLSchedStartTimeTueMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 8 }
tnCesLLSchedStopTimeTueHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 9 }
tnCesLLSchedStopTimeTueMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 10 }
tnCesLLSchedStartTimeWedHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 11 }
tnCesLLSchedStartTimeWedMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 12 }
tnCesLLSchedStopTimeWedHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 13 }
tnCesLLSchedStopTimeWedMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 14 }
tnCesLLSchedStartTimeThuHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 15 }
tnCesLLSchedStartTimeThuMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 16 }
tnCesLLSchedStopTimeThuHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 17 }
tnCesLLSchedStopTimeThuMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 18 }
tnCesLLSchedStartTimeFriHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 19 }
tnCesLLSchedStartTimeFriMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 20 }
tnCesLLSchedStopTimeFriHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 21 }
tnCesLLSchedStopTimeFriMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 22 }
tnCesLLSchedStartTimeSatHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 23 }
tnCesLLSchedStartTimeSatMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 24 }
tnCesLLSchedStopTimeSatHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 25 }
tnCesLLSchedStopTimeSatMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 26 }
tnCesLLSchedStartTimeSunHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 27 }
tnCesLLSchedStartTimeSunMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLSchedEntry 28 }
tnCesLLSchedStopTimeSunHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 29 }
tnCesLLSchedStopTimeSunMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLSchedEntry 30 }
-- Logical link dynamic jitter buffer adjustment configuration.
tnCesLLJATable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesLLJAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of logical link dynamic jitter buffer adjustment configuration."
::= { tnCesObjects 14 }
tnCesLLJAEntry OBJECT-TYPE
SYNTAX TnCesLLJAEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the current dynamic jitter adjustment configuration of a logical link."
INDEX { tnCesLLJANumber }
::= { tnCesLLJATable 1 }
TnCesLLJAEntry ::= SEQUENCE {
tnCesLLJANumber Unsigned32,
tnCesLLJitterAdjustmentMode INTEGER,
tnCesLLJitterAdjustmentAfter Unsigned32,
tnCesLLJASchedStartTimeMonHours Unsigned32,
tnCesLLJASchedStartTimeMonMins Unsigned32,
tnCesLLJASchedStopTimeMonHours Unsigned32,
tnCesLLJASchedStopTimeMonMins Unsigned32,
tnCesLLJASchedStartTimeTueHours Unsigned32,
tnCesLLJASchedStartTimeTueMins Unsigned32,
tnCesLLJASchedStopTimeTueHours Unsigned32,
tnCesLLJASchedStopTimeTueMins Unsigned32,
tnCesLLJASchedStartTimeWedHours Unsigned32,
tnCesLLJASchedStartTimeWedMins Unsigned32,
tnCesLLJASchedStopTimeWedHours Unsigned32,
tnCesLLJASchedStopTimeWedMins Unsigned32,
tnCesLLJASchedStartTimeThuHours Unsigned32,
tnCesLLJASchedStartTimeThuMins Unsigned32,
tnCesLLJASchedStopTimeThuHours Unsigned32,
tnCesLLJASchedStopTimeThuMins Unsigned32,
tnCesLLJASchedStartTimeFriHours Unsigned32,
tnCesLLJASchedStartTimeFriMins Unsigned32,
tnCesLLJASchedStopTimeFriHours Unsigned32,
tnCesLLJASchedStopTimeFriMins Unsigned32,
tnCesLLJASchedStartTimeSatHours Unsigned32,
tnCesLLJASchedStartTimeSatMins Unsigned32,
tnCesLLJASchedStopTimeSatHours Unsigned32,
tnCesLLJASchedStopTimeSatMins Unsigned32,
tnCesLLJASchedStartTimeSunHours Unsigned32,
tnCesLLJASchedStartTimeSunMins Unsigned32,
tnCesLLJASchedStopTimeSunHours Unsigned32,
tnCesLLJASchedStopTimeSunMins Unsigned32
}
tnCesLLJANumber OBJECT-TYPE
SYNTAX Unsigned32 (1..128)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The logical link number."
::= { tnCesLLJAEntry 1 }
tnCesLLJitterAdjustmentMode OBJECT-TYPE
SYNTAX INTEGER {
none (0),
always (1),
schedule (2),
once (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mode in which automatic jitter buffer adustment is to be run. None - No automatic adjuistment of the jitter buffer will be carried out for this logical link. Always - Automatic jitter buffer adjustment is carried out periodically for this logical link while it is active. Schedule - Automatic jitter buffer adjustment is carried out periodically while this link is active during the specified schedule times. Once - Automatic jitter buffer adjustment is carried out once after this logical link becomes active."
::= { tnCesLLJAEntry 2 }
tnCesLLJitterAdjustmentAfter OBJECT-TYPE
SYNTAX Unsigned32 (3..999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"How long to wait in minutes before doing any jitter buffer adjustment once the logical link has become active. Only used when tnCesLLJitterAdjustmentMode is always or once."
::= { tnCesLLJAEntry 3 }
tnCesLLJASchedStartTimeMonHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 4 }
tnCesLLJASchedStartTimeMonMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 5 }
tnCesLLJASchedStopTimeMonHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 6 }
tnCesLLJASchedStopTimeMonMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 7 }
tnCesLLJASchedStartTimeTueHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 8 }
tnCesLLJASchedStartTimeTueMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 9 }
tnCesLLJASchedStopTimeTueHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 10 }
tnCesLLJASchedStopTimeTueMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 11 }
tnCesLLJASchedStartTimeWedHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 12 }
tnCesLLJASchedStartTimeWedMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 13 }
tnCesLLJASchedStopTimeWedHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 14 }
tnCesLLJASchedStopTimeWedMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 15 }
tnCesLLJASchedStartTimeThuHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 16 }
tnCesLLJASchedStartTimeThuMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 17 }
tnCesLLJASchedStopTimeThuHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 18 }
tnCesLLJASchedStopTimeThuMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 19 }
tnCesLLJASchedStartTimeFriHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 20 }
tnCesLLJASchedStartTimeFriMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 21 }
tnCesLLJASchedStopTimeFriHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 22 }
tnCesLLJASchedStopTimeFriMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 23 }
tnCesLLJASchedStartTimeSatHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 24 }
tnCesLLJASchedStartTimeSatMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 25 }
tnCesLLJASchedStopTimeSatHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 26 }
tnCesLLJASchedStopTimeSatMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 27 }
tnCesLLJASchedStartTimeSunHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 28 }
tnCesLLJASchedStartTimeSunMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule start time. The start time must not be later than the stop time."
::= { tnCesLLJAEntry 29 }
tnCesLLJASchedStopTimeSunHours OBJECT-TYPE
SYNTAX Unsigned32 (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hours component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 30 }
tnCesLLJASchedStopTimeSunMins OBJECT-TYPE
SYNTAX Unsigned32 (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minutes component of schedule stop time. The stop time must not be earlier than the start time."
::= { tnCesLLJAEntry 31 }
-- Logical link channel selection configuration.
tnCesLLChanSelectTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesLLChanSelectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of TDM channels selected for a logical link."
::= { tnCesObjects 15 }
tnCesLLChanSelectEntry OBJECT-TYPE
SYNTAX TnCesLLChanSelectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the channel selection configuration of a logical link."
INDEX { tnCesLLChanSelectLLNumber,
tnCesLLChanSelectPortNumber }
::= { tnCesLLChanSelectTable 1 }
TnCesLLChanSelectEntry ::= SEQUENCE {
tnCesLLChanSelectLLNumber Unsigned32,
tnCesLLChanSelectPortNumber Unsigned32,
tnCesLLChanSelectAvailable Unsigned32,
tnCesLLChanSelectUsed Unsigned32
}
tnCesLLChanSelectLLNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..128)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The logical link number."
::= { tnCesLLChanSelectEntry 1 }
tnCesLLChanSelectPortNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The TDM or RS530 port number."
::= { tnCesLLChanSelectEntry 2 }
tnCesLLChanSelectAvailable OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bitmap of whether each channel on this TDM port is available for use by this logical link. Channels are unavailable if they unavailable in the TDM port configuration (full/fractional/E1/T1) or are already selected for another logical link. Bit 0 is for the first channel, bit one for the second, etc."
::= { tnCesLLChanSelectEntry 3 }
tnCesLLChanSelectUsed OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bitmap of whether each channel on this TDM port is assigned for use by this logical link. A channel cannot be assigned to a logical link if the channel is unavailable in the TDM port configuration (full/fractional/E1/T1), the channel is already assigned to another logical link, the channel is on a different TDM port from other channels in this link, or the logical link would have more than 32 channels assigned. Bit 0 is for the first channel, bit one for the second, etc. For products with RS530 ports, this item is ignored. The channels used will be configured automatically from the serial port bitrate whenever this table entry is updated."
::= { tnCesLLChanSelectEntry 4 }
-- Alternate clock architecture stream configuration.
tnCesLLAlternateTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesLLAlternateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of logical link configuration items for the alternate clocking mode."
::= { tnCesObjects 16 }
tnCesLLAlternateEntry OBJECT-TYPE
SYNTAX TnCesLLAlternateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the logical link configuration for the alternate clocking mode."
INDEX { tnCesLLAlternateLLNumber }
::= { tnCesLLAlternateTable 1 }
TnCesLLAlternateEntry ::= SEQUENCE {
tnCesLLAlternateLLNumber Unsigned32,
tnCesLLPlesiosynchronous TruthValue,
tnCesLLAsymmetric TruthValue,
tnCesLLBytesPerPacketRx Unsigned32,
tnCesLLBytesPerPacketTx Unsigned32
}
tnCesLLAlternateLLNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The clocking stream / logical link number."
::= { tnCesLLAlternateEntry 1 }
tnCesLLPlesiosynchronous OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether clocking for stream is plesiosynchronous. Only used when tnCesClockingAlternateEnable is true."
::= { tnCesLLAlternateEntry 2 }
tnCesLLAsymmetric OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Asymmetric clocking mode. Only applies when the associated TDM port is full and when tnCesClockingAlternateEnable is true."
::= { tnCesLLAlternateEntry 3 }
tnCesLLBytesPerPacketRx OBJECT-TYPE
SYNTAX Unsigned32 (1..1500)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In unframed mode, the number of bytes in the packet payload for the logical link in the receive direction."
::= { tnCesLLAlternateEntry 4 }
tnCesLLBytesPerPacketTx OBJECT-TYPE
SYNTAX Unsigned32 (1..1500)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In unframed mode, the number of bytes in the packet payload for the logical link in the transmit direction."
::= { tnCesLLAlternateEntry 5 }
-- Logical link status.
tnCesLLStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesLLStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of logical link status."
::= { tnCesObjects 17 }
tnCesLLStatusEntry OBJECT-TYPE
SYNTAX TnCesLLStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the current status of a logical link."
INDEX { tnCesLLStatusNumber }
::= { tnCesLLStatusTable 1 }
TnCesLLStatusEntry ::= SEQUENCE {
tnCesLLStatusNumber Unsigned32,
tnCesLLStatusEnabled TruthValue,
tnCesLLStatusActive TruthValue,
tnCesLLStatusArpResolved TruthValue,
tnCesLLStatusNumberOfChannels Unsigned32,
tnCesLLStatusRemoteMac MacAddress,
tnCesLLStatusRemoteIpAddrType InetAddressType,
tnCesLLStatusRemoteIpAddr InetAddress,
tnCesLLStatusRemoteContextKnown TruthValue,
tnCesLLStatusRemoteContextNumber Unsigned32,
tnCesLLStatusRemotePortKnown TruthValue,
tnCesLLStatusRemotePort Unsigned32,
tnCesLLStatusQueueLengthValid TruthValue,
tnCesLLStatusMinQueueLength Unsigned32,
tnCesLLStatusMaxQueueLength Unsigned32,
tnCesLLStatusAveQueueLengthWhole Unsigned32,
tnCesLLStatusAveQueueLengthFrac Unsigned32,
tnCesLLStatusEarly Counter32,
tnCesLLStatusLate Counter32,
tnCesLLStatusUnderrun Counter32,
tnCesLLStatusLastSequence Counter32,
tnCesLLStatusPacketsRx Counter32,
tnCesLLStatusPacketsTx Counter32,
tnCesLLStatusSlipsReduceCount Counter32,
tnCesLLStatusSlipsExtendCount Counter32,
tnCesLLLocalLoop TruthValue,
tnCesLLRemoteLoop TruthValue,
tnCesLLNudge Integer32,
tnCesLLResetErrorStats TruthValue
}
tnCesLLStatusNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..128)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The logical link number."
::= { tnCesLLStatusEntry 1 }
tnCesLLStatusEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether the logical link is enabled for use."
::= { tnCesLLStatusEntry 2 }
tnCesLLStatusActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether the logical link is active."
::= { tnCesLLStatusEntry 3 }
tnCesLLStatusArpResolved OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether address resolution has been completed for the logical link."
::= { tnCesLLStatusEntry 4 }
tnCesLLStatusNumberOfChannels OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of TDM channels being transported by this logical link."
::= { tnCesLLStatusEntry 5 }
tnCesLLStatusRemoteMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of the remote end of the logical link, or the gateway MAC address when the remote end is on a different IP subnet."
::= { tnCesLLStatusEntry 6 }
tnCesLLStatusRemoteIpAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address type of the remote end of the logical link."
::= { tnCesLLStatusEntry 7 }
tnCesLLStatusRemoteIpAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address of the remote end of the logical link."
::= { tnCesLLStatusEntry 8 }
tnCesLLStatusRemoteContextKnown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether the logical link number on the remote end is known."
::= { tnCesLLStatusEntry 9 }
tnCesLLStatusRemoteContextNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The logical link number on the remote end (if known)."
::= { tnCesLLStatusEntry 10 }
tnCesLLStatusRemotePortKnown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether the UDP port number of the remote end of the logical link is known."
::= { tnCesLLStatusEntry 11 }
tnCesLLStatusRemotePort OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The UDP port number of the remote end of the logical link (if known)."
::= { tnCesLLStatusEntry 12 }
tnCesLLStatusQueueLengthValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether the jitter buffer statistics are available for the logical link."
::= { tnCesLLStatusEntry 13 }
tnCesLLStatusMinQueueLength OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum fill level of the logical link jitter buffer."
::= { tnCesLLStatusEntry 14 }
tnCesLLStatusMaxQueueLength OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum fill level of the logical link jitter buffer."
::= { tnCesLLStatusEntry 15 }
tnCesLLStatusAveQueueLengthWhole OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average fill level of the logical link jitter buffer. Whole part before the decimal point."
::= { tnCesLLStatusEntry 16 }
tnCesLLStatusAveQueueLengthFrac OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average fill level of the logical link jitter buffer. Fractional part after the decimal point."
::= { tnCesLLStatusEntry 17 }
tnCesLLStatusEarly OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets which arrived too early to be put into the logical link jitter buffer."
::= { tnCesLLStatusEntry 18 }
tnCesLLStatusLate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets which arrived too late to be put into the logical link jitter buffer."
::= { tnCesLLStatusEntry 19 }
tnCesLLStatusUnderrun OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of underruns on the TDM interface caused by missing packets in the logical link jitter buffer."
::= { tnCesLLStatusEntry 20 }
tnCesLLStatusLastSequence OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sequence number of the last packet received for the logical link."
::= { tnCesLLStatusEntry 21 }
tnCesLLStatusPacketsRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received on the logical link."
::= { tnCesLLStatusEntry 22 }
tnCesLLStatusPacketsTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets transmitted on the logical link."
::= { tnCesLLStatusEntry 23 }
tnCesLLStatusSlipsReduceCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the jitter buffer has been slipped to reduced latency."
::= { tnCesLLStatusEntry 24 }
tnCesLLStatusSlipsExtendCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the jitter buffer has been slipped to extend latency."
::= { tnCesLLStatusEntry 25 }
tnCesLLLocalLoop OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether the logical link local loop is enabled."
::= { tnCesLLStatusEntry 26 }
tnCesLLRemoteLoop OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether the logical link remote loop is enabled."
::= { tnCesLLStatusEntry 27 }
tnCesLLNudge OBJECT-TYPE
SYNTAX Integer32 (-128..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of packets by which to nudge the jitter buffer for this logical link. A positive number extends the latency, a negative number reduces the latency, zero has no effect."
::= { tnCesLLStatusEntry 28 }
tnCesLLResetErrorStats OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set to true to reset the jitter buffer error counts for this logical link."
::= { tnCesLLStatusEntry 29 }
-- TDM port status.
tnCesTDMStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesTDMStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of TDM port status."
::= { tnCesObjects 18 }
tnCesTDMStatusEntry OBJECT-TYPE
SYNTAX TnCesTDMStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the current status of a TDM port."
INDEX { tnCesTDMStatusNumber }
::= { tnCesTDMStatusTable 1 }
TnCesTDMStatusEntry ::= SEQUENCE {
tnCesTDMStatusNumber Unsigned32,
tnCesTDMStatusPhysical DisplayString,
tnCesTDMStatusRxSignalLevel DisplayString,
tnCesTDMStatusRxError DisplayString,
tnCesTDMLocalLoop TruthValue,
tnCesTDMRemoteLoop TruthValue,
tnCesTDMBreakCalls TruthValue
}
tnCesTDMStatusNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The TDM port number."
::= { tnCesTDMStatusEntry 1 }
tnCesTDMStatusPhysical OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical layer state of the TDM port."
::= { tnCesTDMStatusEntry 2 }
tnCesTDMStatusRxSignalLevel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive signal level on the TDM port."
::= { tnCesTDMStatusEntry 3 }
tnCesTDMStatusRxError OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive error status of the TDM port."
::= { tnCesTDMStatusEntry 4 }
tnCesTDMLocalLoop OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether the TDM port local loop is enabled."
::= { tnCesTDMStatusEntry 5 }
tnCesTDMRemoteLoop OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether the TDM port remote loop is enabled."
::= { tnCesTDMStatusEntry 6 }
tnCesTDMBreakCalls OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set to true to break the CES connections or ISDN calls active on this port."
::= { tnCesTDMStatusEntry 7 }
-- Call status.
tnCesCallStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesCallStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of calls."
::= { tnCesObjects 19 }
tnCesCallStatusEntry OBJECT-TYPE
SYNTAX TnCesCallStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the current status of a CES call."
INDEX { tnCesCallStatusNumber }
::= { tnCesCallStatusTable 1 }
TnCesCallStatusEntry ::= SEQUENCE {
tnCesCallStatusNumber Unsigned32,
tnCesCallStatusStartTime DateAndTime,
tnCesCallStatusSource DisplayString,
tnCesCallStatusDestination DisplayString,
tnCesCallStatusOriginator TruthValue,
tnCesCallStatusDestinationNumber DisplayString,
tnCesCallStatusSourceNumber DisplayString,
tnCesCallStatusState DisplayString
}
tnCesCallStatusNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The CES call number."
::= { tnCesCallStatusEntry 1 }
tnCesCallStatusStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time the call was started."
::= { tnCesCallStatusEntry 2 }
tnCesCallStatusSource OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Source interface of the call."
::= { tnCesCallStatusEntry 3 }
tnCesCallStatusDestination OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Destination interface of the call."
::= { tnCesCallStatusEntry 4 }
tnCesCallStatusOriginator OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether this system originated the call."
::= { tnCesCallStatusEntry 5 }
tnCesCallStatusDestinationNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Destination number of the call."
::= { tnCesCallStatusEntry 6 }
tnCesCallStatusSourceNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Source number of the call."
::= { tnCesCallStatusEntry 7 }
tnCesCallStatusState OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the call."
::= { tnCesCallStatusEntry 8 }
-- Per stream clocking status.
tnCesClockStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesClockStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of clock recovery status."
::= { tnCesObjects 20 }
tnCesClockStatusEntry OBJECT-TYPE
SYNTAX TnCesClockStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the current status of a CES clock stream."
INDEX { tnCesClockStatusStreamNumber }
::= { tnCesClockStatusTable 1 }
TnCesClockStatusEntry ::= SEQUENCE {
tnCesClockStatusStreamNumber Unsigned32,
tnCesClockStatusStreamStatus INTEGER,
tnCesClockStatusStreamMode INTEGER,
tnCesClockStatusStreamDCO Integer32,
tnCesClockStatusStreamDCOMin Integer32,
tnCesClockStatusStreamDCOMax Integer32,
tnCesClockStatusStreamDCOAvg Integer32
}
tnCesClockStatusStreamNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The CES clock stream number."
::= { tnCesClockStatusEntry 1 }
tnCesClockStatusStreamStatus OBJECT-TYPE
SYNTAX INTEGER {
freerun (0),
holdover (1),
acquiring (2),
acquired (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the clock recovery on the clock stream."
::= { tnCesClockStatusEntry 2 }
tnCesClockStatusStreamMode OBJECT-TYPE
SYNTAX INTEGER {
clockRecoveryDisabled (0),
adaptive (1),
adaptiveEnhanced (2),
adaptiveFrequency (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The clock recovery algorithm running on the clock stream, or disabled if no clock recovery is running."
::= { tnCesClockStatusEntry 3 }
tnCesClockStatusStreamDCO OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Recovered clock frequency offset in PPB. NB Limited to 32 bit range."
::= { tnCesClockStatusEntry 4 }
tnCesClockStatusStreamDCOMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of the recovered clock frequency offset in PPB. NB Limited to 32 bit range."
::= { tnCesClockStatusEntry 5 }
tnCesClockStatusStreamDCOMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum value of the recovered clock frequency offset in PPB. NB Limited to 32 bit range."
::= { tnCesClockStatusEntry 6 }
tnCesClockStatusStreamDCOAvg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average value of the recovered clock frequency offset in PPB. NB Limited to 32 bit range."
::= { tnCesClockStatusEntry 7 }
-- Debug settings.
tnCesDebug OBJECT IDENTIFIER ::= { tnCesObjects 21 }
tnCesDebugTDMTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesDebugTDMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of TDM port debug settings."
::= { tnCesDebug 1 }
tnCesDebugTDMEntry OBJECT-TYPE
SYNTAX TnCesDebugTDMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the debug setting for a TDM port."
INDEX { tnCesDebugTDMPortNumber }
::= { tnCesDebugTDMTable 1 }
TnCesDebugTDMEntry ::= SEQUENCE {
tnCesDebugTDMPortNumber Unsigned32,
tnCesDebugTDMPortEnable TruthValue
}
tnCesDebugTDMPortNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The TDM port number."
::= { tnCesDebugTDMEntry 1 }
tnCesDebugTDMPortEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether to enable (true) or disable (false) debug on this TDM port."
::= { tnCesDebugTDMEntry 2 }
tnCesDebugLLTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesDebugLLEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of logical link debug settings."
::= { tnCesDebug 2 }
tnCesDebugLLEntry OBJECT-TYPE
SYNTAX TnCesDebugLLEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the current debug setting for a logical link."
INDEX { tnCesDebugLLNumber }
::= { tnCesDebugLLTable 1 }
TnCesDebugLLEntry ::= SEQUENCE {
tnCesDebugLLNumber Unsigned32,
tnCesDebugLLEnable TruthValue
}
tnCesDebugLLNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..128)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The logical link number."
::= { tnCesDebugLLEntry 1 }
tnCesDebugLLEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether to enable (true) or disable (false) debug on this logical link."
::= { tnCesDebugLLEntry 2 }
tnCesDebugMiscTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesDebugMiscEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of miscellaneous debug settings."
::= { tnCesDebug 3 }
tnCesDebugMiscEntry OBJECT-TYPE
SYNTAX TnCesDebugMiscEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the current debug setting for a miscellaneous item."
INDEX { tnCesDebugMiscItem }
::= { tnCesDebugMiscTable 1 }
TnCesDebugMiscEntry ::= SEQUENCE {
tnCesDebugMiscItem INTEGER,
tnCesDebugMiscEnable TruthValue
}
tnCesDebugMiscItem OBJECT-TYPE
SYNTAX INTEGER {
control (1),
arp (2),
sip (3),
logicalLinkControl (4),
logicalLinkGlobal (5)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The debug item to enable or disable."
::= { tnCesDebugMiscEntry 1 }
tnCesDebugMiscEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether to enable (true) or disable (false) debug for this item."
::= { tnCesDebugMiscEntry 2 }
-- RS530 serial port configuration.
tnCesRS530Table OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesRS530Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of RS530 serial ports."
::= { tnCesObjects 22 }
tnCesRS530Entry OBJECT-TYPE
SYNTAX TnCesRS530Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the configuration for a RS530 serial port."
INDEX { tnCesRS530PortNumber }
::= { tnCesRS530Table 1 }
TnCesRS530Entry ::= SEQUENCE {
tnCesRS530PortNumber Unsigned32,
tnCesRS530Rate Unsigned32,
tnCesRS530ShutdownCallsOnFail TruthValue
}
tnCesRS530PortNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RS530 serial port number."
::= { tnCesRS530Entry 1 }
tnCesRS530Rate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RS530 serial port bit rate in bits per second. Valid rates are 64K to 2048K in 64K steps, or one of the following subrates: 38400, 19200, 9600, 4800, 2400."
::= { tnCesRS530Entry 2 }
tnCesRS530ShutdownCallsOnFail OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether to shutdown the CES connections using this port when the port fails."
::= { tnCesRS530Entry 3 }
-- RS530 serial port status.
tnCesRS530StatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnCesRS530StatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of RS530 serial port status."
::= { tnCesObjects 23 }
tnCesRS530StatusEntry OBJECT-TYPE
SYNTAX TnCesRS530StatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry has the current status of a RS530 serial port."
INDEX { tnCesRS530StatusNumber }
::= { tnCesRS530StatusTable 1 }
TnCesRS530StatusEntry ::= SEQUENCE {
tnCesRS530StatusNumber Unsigned32,
tnCesRS530InterfaceType DisplayString,
tnCesRS530StatusDTR TruthValue,
tnCesRS530StatusDCD TruthValue,
tnCesRS530StatusRTS TruthValue,
tnCesRS530StatusCTS TruthValue,
tnCesRS530StatusDSR TruthValue,
tnCesRS530LocalLoop TruthValue,
tnCesRS530RemoteLoop TruthValue,
tnCesRS530BreakCalls TruthValue
}
tnCesRS530StatusNumber OBJECT-TYPE
SYNTAX Unsigned32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RS530 serial port number."
::= { tnCesRS530StatusEntry 1 }
tnCesRS530InterfaceType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the type of physical interface used by the RS530 serial."
::= { tnCesRS530StatusEntry 2 }
tnCesRS530StatusDTR OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the RS530 serial port C/DTR lead."
::= { tnCesRS530StatusEntry 3 }
tnCesRS530StatusDCD OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the RS530 serial port I/DCD lead."
::= { tnCesRS530StatusEntry 4 }
tnCesRS530StatusRTS OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the RS530 serial port RTS lead."
::= { tnCesRS530StatusEntry 5 }
tnCesRS530StatusCTS OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the RS530 serial port CTS lead."
::= { tnCesRS530StatusEntry 6 }
tnCesRS530StatusDSR OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the RS530 serial port DSR lead."
::= { tnCesRS530StatusEntry 7 }
tnCesRS530LocalLoop OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether the RS530 serial port local loop is enabled."
::= { tnCesRS530StatusEntry 8 }
tnCesRS530RemoteLoop OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether the RS530 port remote loop is enabled."
::= { tnCesRS530StatusEntry 9 }
tnCesRS530BreakCalls OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set to true to break the CES connections or ISDN calls active on this port."
::= { tnCesRS530StatusEntry 10 }
-- Traps
tnCesEventDetails OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Text information describing the event that has occurred."
::= { tnCesNotifications 1 }
tnCesEventPriority OBJECT-TYPE
SYNTAX Unsigned32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Priority of this event."
::= { tnCesNotifications 2 }
tnCesGeneralEvent NOTIFICATION-TYPE
OBJECTS
{
tnCesEventDetails,
tnCesEventPriority
}
STATUS current
DESCRIPTION
"Notification of an event relating to CES."
::= { tnCesEventIdGeneral 1 }
-- Compliance section.
tnCesGroup OBJECT-GROUP
OBJECTS { tnCesMiscClockPriority,
tnCesPRIClockPriority,
tnCesLLClockPriority,
tnCesEventThreshold,
tnCesEventReportingInterval,
tnCesEventThresholdEarly,
tnCesEventThresholdLate,
tnCesEventThresholdUnderrun,
tnCesEventThresholdDCO,
tnCesMulticastJoinAction,
tnCesMulticastJoinAddrType,
tnCesMulticastJoinAddr,
tnCesProtocolUnderrunFixed,
tnCesProtocolUnderrunValue,
tnCesProtocolUDPBasePort,
tnCesProtocolType,
tnCesProtocolEnableSSRCChecking,
tnCesClockRecoveryAlgorithm,
tnCesClockRecoveryFilter,
tnCesClockRecoveryMaxDeviation,
tnCesTDMPresentation,
tnCesTDMFraming,
tnCesTDMMode,
tnCesTDMTS0Passthrough,
tnCesTDMCRC4,
tnCesTDMShutdownCallsOnFail,
tnCesTDMImpedance,
tnCesTDMT1Framing,
tnCesTDMT1LineCode,
tnCesTDMT1LoopCodeType,
tnCesTDMT1LoopCodeRxEnable,
tnCesTDMT1LoopCodeUserDown,
tnCesTDMT1LoopCodeUserUp,
tnCesTDMT1LoopCodeUserLength,
tnCesTDMDTE,
tnCesLLname,
tnCesLLDirection,
tnCesLLRemoteIpAddrType,
tnCesLLRemoteIpAddr,
tnCesLLSecondaryRemoteIpAddrType,
tnCesLLSecondaryRemoteIpAddr,
tnCesLLQosType,
tnCesLLQosTOS,
tnCesLLQosDiffserv,
tnCesLLVlanTag,
tnCesLLVlanId,
tnCesLLVlanPriority,
tnCesLLJitterBufferLength,
tnCesLLFramesPerPacket,
tnCesLLRemoteLinkNumber,
tnCesLLSchedEnable,
tnCesLLSchedStartTimeMonHours,
tnCesLLSchedStartTimeMonMins,
tnCesLLSchedStopTimeMonHours,
tnCesLLSchedStopTimeMonMins,
tnCesLLSchedStartTimeTueHours,
tnCesLLSchedStartTimeTueMins,
tnCesLLSchedStopTimeTueHours,
tnCesLLSchedStopTimeTueMins,
tnCesLLSchedStartTimeWedHours,
tnCesLLSchedStartTimeWedMins,
tnCesLLSchedStopTimeWedHours,
tnCesLLSchedStopTimeWedMins,
tnCesLLSchedStartTimeThuHours,
tnCesLLSchedStartTimeThuMins,
tnCesLLSchedStopTimeThuHours,
tnCesLLSchedStopTimeThuMins,
tnCesLLSchedStartTimeFriHours,
tnCesLLSchedStartTimeFriMins,
tnCesLLSchedStopTimeFriHours,
tnCesLLSchedStopTimeFriMins,
tnCesLLSchedStartTimeSatHours,
tnCesLLSchedStartTimeSatMins,
tnCesLLSchedStopTimeSatHours,
tnCesLLSchedStopTimeSatMins,
tnCesLLSchedStartTimeSunHours,
tnCesLLSchedStartTimeSunMins,
tnCesLLSchedStopTimeSunHours,
tnCesLLSchedStopTimeSunMins,
tnCesLLJitterAdjustmentMode,
tnCesLLJitterAdjustmentAfter,
tnCesLLJASchedStartTimeMonHours,
tnCesLLJASchedStartTimeMonMins,
tnCesLLJASchedStopTimeMonHours,
tnCesLLJASchedStopTimeMonMins,
tnCesLLJASchedStartTimeTueHours,
tnCesLLJASchedStartTimeTueMins,
tnCesLLJASchedStopTimeTueHours,
tnCesLLJASchedStopTimeTueMins,
tnCesLLJASchedStartTimeWedHours,
tnCesLLJASchedStartTimeWedMins,
tnCesLLJASchedStopTimeWedHours,
tnCesLLJASchedStopTimeWedMins,
tnCesLLJASchedStartTimeThuHours,
tnCesLLJASchedStartTimeThuMins,
tnCesLLJASchedStopTimeThuHours,
tnCesLLJASchedStopTimeThuMins,
tnCesLLJASchedStartTimeFriHours,
tnCesLLJASchedStartTimeFriMins,
tnCesLLJASchedStopTimeFriHours,
tnCesLLJASchedStopTimeFriMins,
tnCesLLJASchedStartTimeSatHours,
tnCesLLJASchedStartTimeSatMins,
tnCesLLJASchedStopTimeSatHours,
tnCesLLJASchedStopTimeSatMins,
tnCesLLJASchedStartTimeSunHours,
tnCesLLJASchedStartTimeSunMins,
tnCesLLJASchedStopTimeSunHours,
tnCesLLJASchedStopTimeSunMins,
tnCesLLChanSelectAvailable,
tnCesLLChanSelectUsed,
tnCesClockingAlternateEnable,
tnCesLLPlesiosynchronous,
tnCesLLAsymmetric,
tnCesLLBytesPerPacketRx,
tnCesLLBytesPerPacketTx,
tnCesLLStatusEnabled,
tnCesLLStatusActive,
tnCesLLStatusArpResolved,
tnCesLLStatusNumberOfChannels,
tnCesLLStatusRemoteMac,
tnCesLLStatusRemoteIpAddrType,
tnCesLLStatusRemoteIpAddr,
tnCesLLStatusRemoteContextKnown,
tnCesLLStatusRemoteContextNumber,
tnCesLLStatusRemotePortKnown,
tnCesLLStatusRemotePort,
tnCesLLStatusQueueLengthValid,
tnCesLLStatusMinQueueLength,
tnCesLLStatusMaxQueueLength,
tnCesLLStatusAveQueueLengthWhole,
tnCesLLStatusAveQueueLengthFrac,
tnCesLLStatusEarly,
tnCesLLStatusLate,
tnCesLLStatusUnderrun,
tnCesLLStatusLastSequence,
tnCesLLStatusPacketsRx,
tnCesLLStatusPacketsTx,
tnCesLLStatusSlipsReduceCount,
tnCesLLStatusSlipsExtendCount,
tnCesLLLocalLoop,
tnCesLLRemoteLoop,
tnCesLLNudge,
tnCesLLResetErrorStats,
tnCesTDMStatusPhysical,
tnCesTDMStatusRxSignalLevel,
tnCesTDMStatusRxError,
tnCesTDMLocalLoop,
tnCesTDMRemoteLoop,
tnCesTDMBreakCalls,
tnCesProcessorVersion,
tnCesProcessorProtocolMatch1,
tnCesProcessorProtocolMatch2,
tnCesProcessorProtocolMatch3,
tnCesProcessorProtocolMatch4,
tnCesProcessorProtocolNoMatch,
tnCesProcessorClassifyFail,
tnCesProcessorVerifyFail,
tnCesProcessorIpv4ChecksumFail,
tnCesProcessorUdpChecksumFail,
tnCesCallStatusStartTime,
tnCesCallStatusSource,
tnCesCallStatusDestination,
tnCesCallStatusOriginator,
tnCesCallStatusDestinationNumber,
tnCesCallStatusSourceNumber,
tnCesCallStatusState,
tnCesClockStatusLock,
tnCesClockStatusSlaveMode,
tnCesClockStatusSource,
tnCesClockStatusStreamStatus,
tnCesClockStatusStreamMode,
tnCesClockStatusStreamDCO,
tnCesClockStatusStreamDCOMin,
tnCesClockStatusStreamDCOMax,
tnCesClockStatusStreamDCOAvg,
tnCesTemperatureBoardWhole,
tnCesTemperatureBoardFrac,
tnCesTemperatureProcessorWhole,
tnCesTemperatureProcessorFrac,
tnCesDebugTDMPortEnable,
tnCesDebugLLEnable,
tnCesDebugMiscEnable,
tnCesEventDetails,
tnCesEventPriority,
tnCesRS530Rate,
tnCesRS530ShutdownCallsOnFail,
tnCesRS530InterfaceType,
tnCesRS530StatusDTR,
tnCesRS530StatusDCD,
tnCesRS530StatusRTS,
tnCesRS530StatusCTS,
tnCesRS530StatusDSR,
tnCesRS530LocalLoop,
tnCesRS530RemoteLoop,
tnCesRS530BreakCalls,
tnCesIpv4AddrType,
tnCesIpv4Addr,
tnCesIpv4PrefixLength,
tnCesIpv6AddrType,
tnCesIpv6Addr,
tnCesIpv6PrefixLength
}
STATUS current
DESCRIPTION
"Objects which implement CES support on a device."
::= { tnCesGroups 1 }
tnCesTrapGroup NOTIFICATION-GROUP
NOTIFICATIONS {
tnCesGeneralEvent
}
STATUS current
DESCRIPTION
"Notifications which implement CES support on a device."
::= { tnCesGroups 2 }
tnCesMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"You will comply. Respect my authority!"
MODULE -- compliance to the containing MIB module
MANDATORY-GROUPS { tnCesGroup, tnCesTrapGroup }
::= { tnCesCompliances 1 }