mibs/MIBS/transition/TN-POWER-SUPPLY-MIB

153 lines
4.3 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
-- ***********************************************************************************************
-- TN-POWER-SUPPLY-MIB.smi: Transition Networks, Inc. Enterprise MIB for power-supply management.
--
-- Copyright (c) 2013 by Transition Networks, Inc.
-- All rights reserved.
--
-- ***********************************************************************************************
--
TN-POWER-SUPPLY-MIB DEFINITIONS ::= BEGIN
IMPORTS
Unsigned32, Counter32
FROM SNMPv2-SMI
TruthValue
FROM SNMPv2-TC
tnProducts
FROM TRANSITION-SMI;
tnPowerSupply MODULE-IDENTITY
LAST-UPDATED "201303120000Z"
ORGANIZATION "Transition Networks, Inc."
CONTACT-INFO
"Transition Networks
Technical Support
10900 Red Circle Drive
Minnetonka, MN 55343 USA
Tel: +1-800-526-9267
E-mail: techsupport@transition.com"
DESCRIPTION
"This mib is related to the manamgement of power-supply."
REVISION "201303120000Z"
DESCRIPTION
"Defined in Mar 12th, 2013."
::= { tnProducts 20 }
TnPowerSupplyPowerType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A kind of variable-type definition indicates the means of power-supply,
AC or DC."
SYNTAX INTEGER {
ac(1),
dc(2)
}
tnPowerSupplyEnvMonNotifications OBJECT IDENTIFIER ::= { tnPowerSupply 1 }
tnPowerSupplyEnvMonFailureNotif NOTIFICATION-TYPE
OBJECTS {
tnPowerSupplyPowered
}
STATUS current
DESCRIPTION
"A tnPowerSupplyEnvMonFailureNotif will be sent when the power-supply
is not functioning properly."
::= { tnPowerSupplyEnvMonNotifications 1 }
tnPowerSupplyEnvMonTemperatureNotif NOTIFICATION-TYPE
OBJECTS {
tnPowerSupplyTemperature
}
STATUS current
DESCRIPTION
"A tnPowerSupplyEnvMonTemperatureNotif will be sent when the
temperature of the power-supply is out of controlled range."
::= { tnPowerSupplyEnvMonNotifications 2 }
tnPowerSupplyMIBObject OBJECT IDENTIFIER ::= { tnPowerSupply 2 }
tnPowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnPowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines the managment of power-supply."
::= { tnPowerSupplyMIBObject 1 }
tnPowerSupplyEntry OBJECT-TYPE
SYNTAX TnPowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the entry of power-supply table."
INDEX { tnPowerSupplyIndex }
::= { tnPowerSupplyTable 1 }
TnPowerSupplyEntry ::=
SEQUENCE {
tnPowerSupplyIndex Unsigned32,
tnPowerSupplyPresent TruthValue,
tnPowerSupplyPowerType TnPowerSupplyPowerType,
tnPowerSupplyPowered TruthValue,
tnPowerSupplyFanRPM Unsigned32,
tnPowerSupplyTemperature INTEGER
}
tnPowerSupplyIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the index of table entry."
::= { tnPowerSupplyEntry 1 }
tnPowerSupplyPresent OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current choice of power-supply."
::= { tnPowerSupplyEntry 2 }
tnPowerSupplyPowerType OBJECT-TYPE
SYNTAX TnPowerSupplyPowerType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the type of power-supply."
::= { tnPowerSupplyEntry 3 }
tnPowerSupplyPowered OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates power-supply is on or off. In this case, true represents powered-on,
and otherwise, powered-off."
::= { tnPowerSupplyEntry 4 }
tnPowerSupplyFanRPM OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the RPM of fan."
::= { tnPowerSupplyEntry 5 }
tnPowerSupplyTemperature OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the temperature of the power-supply."
::= { tnPowerSupplyEntry 6 }
tnPowerSupplyMibConformance OBJECT IDENTIFIER ::= { tnPowerSupply 3 }
END