2023-12-05 12:25:34 +01:00
-- **************************************************************
-- TRELLIX CONFIDENTIAL
-- TRELLIX-SENSOR-PERF-MIB:
-- Trellix Sensor Performance MIB
--
-- Copyright (c) 2022 MUSARUBRA US, LLC
-- All rights reserved.
--
-- *****************************************************************
TRELLIX-SENSOR-PERF-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, Gauge32,
TimeTicks, IpAddress, Counter32, Counter64, Integer32
FROM SNMPv2-SMI
DisplayString, TruthValue
FROM SNMPv2-TC
ivSensorPerformance, intfPortIndex, npIndex,
processorIndex, slotIndex, rateLimitQueueIndex
FROM TRELLIX-SENSOR-SMI;
ivSensorPerformanceMIB MODULE-IDENTITY
LAST-UPDATED "200707090000Z"
ORGANIZATION
"MUSARUBRA US LLC"
CONTACT-INFO
"Trellix Customer Service Department
Postal: 6220 American Center Drive
San Jose CA 95002-2563
Tel: +1-800-338-8754
E-mail: support@mcafee.com"
DESCRIPTION
"The Performance MIB for the Trellix Sensor product."
REVISION "200707090000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { ivSensorPerformance 1 }
sensorCardPerfGrp OBJECT IDENTIFIER ::= { ivSensorPerformanceMIB 1 }
--
-- TCP Perf Table
tcpPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TcpPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sensorCardPerfGrp 1 }
tcpPerfEntry OBJECT-TYPE
SYNTAX TcpPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry is indexed by a fixed value chassis slotIndex of 2 (two) for all models."
INDEX { slotIndex }
::= { tcpPerfTable 1 }
TcpPerfEntry ::= SEQUENCE {
tcpMaxFlowsSupported
Integer32,
tcpActiveTCPFlowsCount
Counter32,
tcpActiveUDPFlowsCount
Counter32,
tcpFlowsCreatedCount
Counter32,
tcpFlowsTimedOutCount
Counter32,
tcpFlowsInTimewaitCount
Counter32,
tcpFlowsInSYNStateCount
Counter32,
tcpInactiveTCPFlowsCount
Counter32,
tcpFreeTCBCount
Counter32,
tcpSynCookieInbStatus
INTEGER,
tcpSynCookieOutbStatus
INTEGER,
tcpSynCookieProxiedConnCount
Counter32
}
tcpMaxFlowsSupported OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of flows supported in the sensor."
::= { tcpPerfEntry 1 }
tcpActiveTCPFlowsCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of TCP flows currently active ( similar to tcpCurrEstablished)"
::= { tcpPerfEntry 2 }
tcpActiveUDPFlowsCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of UDP flows currently active"
::= { tcpPerfEntry 3 }
tcpFlowsCreatedCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of connections established through successful 3-way handshakes"
::= { tcpPerfEntry 4 }
tcpFlowsTimedOutCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of unsuccessful connection completions"
::= { tcpPerfEntry 5 }
tcpFlowsInTimewaitCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of TCP flows currently in timewait state "
::= { tcpPerfEntry 6 }
tcpFlowsInSYNStateCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of TCP flows currently in SYN state "
::= { tcpPerfEntry 7 }
tcpInactiveTCPFlowsCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of TCP flows currently inactive "
::= { tcpPerfEntry 8 }
tcpFreeTCBCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of free TCBs"
::= { tcpPerfEntry 9 }
tcpSynCookieInbStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of syn cookie for inbound TCP connections"
::= { tcpPerfEntry 10 }
tcpSynCookieOutbStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of syn cookie for outbound TCP connections"
::= { tcpPerfEntry 11 }
tcpSynCookieProxiedConnCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of syn cookie proxied TCP connections"
::= { tcpPerfEntry 12 }
--The ifTable contains information on the entity's
--interfaces.
--
intfPortIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntfPortIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sensorCardPerfGrp 3 }
intfPortIfEntry OBJECT-TYPE
SYNTAX IntfPortIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An interface entry containing objects at the
subnetwork layer and below for a particular interface."
INDEX { slotIndex,
intfPortIndex }
::= { intfPortIfTable 1 }
IntfPortIfEntry ::= SEQUENCE {
intfPortTotalPktsRecv
Counter32,
intfPortTotalUnicastPktsRecv
Counter32,
intfPortTotalMulticastPktsRecv
Counter32,
intfPortTotalBroadcastPktsRecv
Counter32,
intfPortTotalBytesRecv
Counter32,
intfPortTotalCRCErrorsRecv
Counter32,
intfPortTotalPktsSent
Counter32,
intfPortTotalUnicastPktsSent
Counter32,
intfPortTotalMulticastPktsSent
Counter32,
intfPortTotalBroadcastPktsSent
Counter32,
intfPortTotalBytesSent
Counter32,
intfPortTotalCRCErrorsSent
Counter32,
intfPortResetCounters
INTEGER,
intfPortNbadFlowRecordCount
Counter32
}
intfPortTotalPktsRecv OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of packets that this interface port has
recieved."
::= { intfPortIfEntry 1 }
intfPortTotalUnicastPktsRecv OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of unicast packets that this interface port has
recieved."
::= { intfPortIfEntry 2 }
intfPortTotalMulticastPktsRecv OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of multicast packets that this interface port
has recieved."
::= { intfPortIfEntry 3 }
intfPortTotalBroadcastPktsRecv OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of unicast packets that this interface port has
recieved."
::= { intfPortIfEntry 4 }
intfPortTotalBytesRecv OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of bytes that this interface port has recieved."
::= { intfPortIfEntry 5 }
intfPortTotalCRCErrorsRecv OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of packets received with bad CRC and bad
alignment."
::= { intfPortIfEntry 6 }
intfPortTotalPktsSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of packets that have been sent on this
interface."
::= { intfPortIfEntry 7 }
intfPortTotalUnicastPktsSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of unicast packets that have been sent on
this interface."
::= { intfPortIfEntry 8 }
intfPortTotalMulticastPktsSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of multicast packets that have been sent on
this interface."
::= { intfPortIfEntry 9 }
intfPortTotalBroadcastPktsSent OBJECT-TYPE
SYNTAX Counter32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of broadcast packets that have been sent on
this interface."
::= { intfPortIfEntry 10 }
intfPortTotalBytesSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of bytes that have been sent on this interface."
::= { intfPortIfEntry 11 }
intfPortTotalCRCErrorsSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of packets that have been sent with bad CRC."
::= { intfPortIfEntry 12 }
intfPortResetCounters OBJECT-TYPE
SYNTAX INTEGER {
reset (0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset all the above (only intfPortIfEntry 1 - 13) counters"
::= { intfPortIfEntry 13 }
intfPortNbadFlowRecordCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of flow records generated from this monitoring port."
::= { intfPortIfEntry 14 }
--The ipSpoofTable contains information on the entity's
--ip spoof stats on the interfaces.
--
intfPortIpSpoofTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntfPortIpSpoofEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sensorCardPerfGrp 4 }
intfPortIpSpoofEntry OBJECT-TYPE
SYNTAX IntfPortIpSpoofEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An interface entry containing objects that
indicate specific IP Spoof Pkt statistics.
"
INDEX { slotIndex,
intfPortIndex }
::= { intfPortIpSpoofTable 1 }
IntfPortIpSpoofEntry ::= SEQUENCE {
intfPortClrSpoofCounts
INTEGER,
intfPortGetInSpoofCount
Counter32,
intfPortGetOutSpoofCount
Counter32
}
intfPortClrSpoofCounts OBJECT-TYPE
SYNTAX INTEGER {
reset (0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset clears all the spoof counters in this table."
::= { intfPortIpSpoofEntry 1 }
intfPortGetInSpoofCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Get the (inside) spoof pkt count."
::= { intfPortIpSpoofEntry 2 }
intfPortGetOutSpoofCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Get the (outside) spoof pkt count."
::= { intfPortIpSpoofEntry 3 }
--
-- Sensor Perfomance Table
--
sensorPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF SensorPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sensorCardPerfGrp 5 }
sensorPerfEntry OBJECT-TYPE
SYNTAX SensorPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table give the sensor performance related information.
This entry is indexed by a fixed value chassis slotIndex of 2 (two) for all models."
INDEX { slotIndex }
::= { sensorPerfTable 1 }
SensorPerfEntry ::= SEQUENCE {
sensorAvgLoad
Integer32,
sensorHighestLoad
Integer32,
pendingIPFragReassemblyCount
Integer32,
totalPacketsLoggedCount
Integer32,
totalAlertsSentCount
Integer32,
sensorLoadIndicatorConfig
Integer32,
sensorMaxTrafficCapacity
Integer32,
sensorTotalBytesProcessed
Counter64,
sensorTotalL2FCount
Counter64
}
sensorAvgLoad OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average percentage utilisation of the sensor processors"
::= { sensorPerfEntry 1 }
sensorHighestLoad OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage utilization of the most loaded sensor processor"
::= { sensorPerfEntry 2 }
pendingIPFragReassemblyCount OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of IP fragment lists currently being reassembled"
::= { sensorPerfEntry 5 }
totalPacketsLoggedCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets logged sent to ISM."
::= { sensorPerfEntry 6 }
totalAlertsSentCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of alerts sent to ISM"
::= { sensorPerfEntry 7 }
sensorLoadIndicatorConfig OBJECT-TYPE
SYNTAX Integer32 {
off (0),
on (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Option to switch off/on the sensor load indicator. This value is not persisted across sensor reboots.
Default : off"
::= { sensorPerfEntry 8 }
sensorMaxTrafficCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the maximum traffic processing capacity (in Mbps) of the sensor over the given slot."
::= { sensorPerfEntry 9 }
sensorTotalBytesProcessed OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the sum of total bytes of data received over all the monitoring ports."
::= { sensorPerfEntry 10 }
sensorTotalL2FCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter gives total number of packets on all ports that
were sent out without going through the sensor due to layer2 forward."
::= { sensorPerfEntry 11 }
--
-- Statistics that gives information about the sensor memory utilization
--
sensorMemUsageTable OBJECT-TYPE
SYNTAX SEQUENCE OF SensorMemUsageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sensorCardPerfGrp 6 }
sensorMemUsageEntry OBJECT-TYPE
SYNTAX SensorMemUsageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry gives information about the sensor memory utilized.
This entry is indexed by a fixed value chassis slotIndex of 2 (two) for all models."
INDEX { slotIndex }
::= { sensorMemUsageTable 1 }
SensorMemUsageEntry ::= SEQUENCE {
sensorAvgTcpUdpFlows
Integer32,
sensorMaxTcpUdpFlows
Integer32,
sensorAvgIpFragFlows
Integer32,
sensorMaxIpFragFlows
Integer32,
sensorAvgIcmpFlows
Integer32,
sensorMaxIcmpFlows
Integer32,
sensorAvgSslFlows
Integer32,
sensorMaxSslFlows
Integer32,
sensorAvgFragReassemblyBuffers
Integer32,
sensorMaxFragReassemblyBuffers
Integer32,
sensorAvgPacketBuffers
Integer32,
sensorMaxPacketBuffers
Integer32,
sensorAvgAttackMarkerNodes
Integer32,
sensorMaxAttackMarkerNodes
Integer32,
sensorAvgShellMarkerNodes
Integer32,
sensorMaxShellMarkerNodes
Integer32,
sensorAvgL7DcapAlertBuffers
Integer32,
sensorMaxL7DcapAlertBuffers
Integer32,
sensorAvgL7DcapFlows
Integer32,
sensorMaxL7DcapFlows
Integer32
}
sensorAvgTcpUdpFlows OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the average percentage of the used TCP and UDP flows across all PEs<45>."
::= { sensorMemUsageEntry 1 }
sensorMaxTcpUdpFlows OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the maximum percentage of the used TCP and UDP flows on a single PE."
::= { sensorMemUsageEntry 2 }
sensorAvgIpFragFlows OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the average percentage of the used IP Fragment flows across all PEs<45>."
::= { sensorMemUsageEntry 3 }
sensorMaxIpFragFlows OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the maximum percentage of the used IP Fragment flows on a single PE."
::= { sensorMemUsageEntry 4 }
sensorAvgIcmpFlows OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the average percentage of the used ICMP flows across all PEs<45>."
::= { sensorMemUsageEntry 5 }
sensorMaxIcmpFlows OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the maximum percentage of the used ICMP flows on a single PE."
::= { sensorMemUsageEntry 6 }
sensorAvgSslFlows OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the average percentage of the used SSL flows across all PEs<45>."
::= { sensorMemUsageEntry 7 }
sensorMaxSslFlows OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the maximum percentage of the used SSL flows on a single PE."
::= { sensorMemUsageEntry 8 }
sensorAvgFragReassemblyBuffers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the average percentage of the used fragment reassembly buffers across all PEs<45>."
::= { sensorMemUsageEntry 9 }
sensorMaxFragReassemblyBuffers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the maximum percentage of the used fragment reassembly buffers on a single PE."
::= { sensorMemUsageEntry 10 }
sensorAvgPacketBuffers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the average percentage of the used packet buffers across all PEs<45>."
::= { sensorMemUsageEntry 11 }
sensorMaxPacketBuffers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the maximum percentage of the used packet buffers on a single PE."
::= { sensorMemUsageEntry 12 }
sensorAvgAttackMarkerNodes OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the average percentage of the used attack marker nodes across all PEs<45>."
::= { sensorMemUsageEntry 13 }
sensorMaxAttackMarkerNodes OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the maximum percentage of the used attack marker nodes on a single PE."
::= { sensorMemUsageEntry 14 }
sensorAvgShellMarkerNodes OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the average percentage of the used shell marker nodes across all PEs<45>."
::= { sensorMemUsageEntry 15 }
sensorMaxShellMarkerNodes OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the maximum percentage of the used shell marker nodes on a single PE."
::= { sensorMemUsageEntry 16 }
sensorAvgL7DcapAlertBuffers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the average percentage of the layer7Dcap buffers across all PEs."
::= { sensorMemUsageEntry 17 }
sensorMaxL7DcapAlertBuffers OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the maximum percentage of the layer7Dcap buffers on a single PE."
::= { sensorMemUsageEntry 18 }
sensorAvgL7DcapFlows OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the average percentage of the layer7Dcap flows across all PEs."
::= { sensorMemUsageEntry 19 }
sensorMaxL7DcapFlows OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This gives the maximum percentage of layer7Dcap flows on a single PE."
::= { sensorMemUsageEntry 20 }
--The intfPortIf64Table contains 64bit counter information on the entity's
--interfaces. It's the 64 bit equivalent of 32bit based intfPortIfTable
--
intfPortIf64Table OBJECT-TYPE
SYNTAX SEQUENCE OF IntfPortIf64Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sensorCardPerfGrp 7 }
intfPortIf64Entry OBJECT-TYPE
SYNTAX IntfPortIf64Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An interface entry containing 64bit counter objects at the
subnetwork layer and below for a particular
interface."
INDEX { slotIndex,
intfPortIndex }
::= { intfPortIf64Table 1 }
IntfPortIf64Entry ::= SEQUENCE {
intfPortTotalPktsRecv64
Counter64,
intfPortTotalUnicastPktsRecv64
Counter64,
intfPortTotalMulticastPktsRecv64
Counter64,
intfPortTotalBroadcastPktsRecv64
Counter64,
intfPortTotalBytesRecv64
Counter64,
intfPortTotalCRCErrorsRecv64
Counter64,
intfPortTotalPktsSent64
Counter64,
intfPortTotalUnicastPktsSent64
Counter64,
intfPortTotalMulticastPktsSent64
Counter64,
intfPortTotalBroadcastPktsSent64
Counter64,
intfPortTotalBytesSent64
Counter64,
intfPortTotalCRCErrorsSent64
Counter64,
intfPortResetCounters64
INTEGER
}
intfPortTotalPktsRecv64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of packets that this interface port has
recieved."
::= { intfPortIf64Entry 1 }
intfPortTotalUnicastPktsRecv64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of unicast packets that this interface port has
recieved."
::= { intfPortIf64Entry 2 }
intfPortTotalMulticastPktsRecv64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of multicast packets that this interface port
has recieved."
::= { intfPortIf64Entry 3 }
intfPortTotalBroadcastPktsRecv64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of unicast packets that this interface port has
recieved."
::= { intfPortIf64Entry 4 }
intfPortTotalBytesRecv64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of bytes that this interface port has recieved."
::= { intfPortIf64Entry 5 }
intfPortTotalCRCErrorsRecv64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of packets received with bad CRC and bad
alignment."
::= { intfPortIf64Entry 6 }
intfPortTotalPktsSent64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of packets that have been sent on this
interface."
::= { intfPortIf64Entry 7 }
intfPortTotalUnicastPktsSent64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of unicast packets that have been sent on
this interface."
::= { intfPortIf64Entry 8 }
intfPortTotalMulticastPktsSent64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of multicast packets that have been sent on
this interface."
::= { intfPortIf64Entry 9 }
intfPortTotalBroadcastPktsSent64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of broadcast packets that have been sent on
this interface."
::= { intfPortIf64Entry 10 }
intfPortTotalBytesSent64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of bytes that have been sent on this interface."
::= { intfPortIf64Entry 11 }
intfPortTotalCRCErrorsSent64 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total 64bit count of packets that have been sent with bad CRC."
::= { intfPortIf64Entry 12 }
intfPortResetCounters64 OBJECT-TYPE
SYNTAX INTEGER {
reset (0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset all the above (only intfPortIf64Entry 1 - 12) counters"
::= { intfPortIf64Entry 13 }
--
-- This group contains Malware related stats. These are applicable to
-- all M-series except NAC-only appliances.
malwareCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF MalwareCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sensorCardPerfGrp 8 }
malwareCounterEntry OBJECT-TYPE
SYNTAX MalwareCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry containing malware specific statistics.
This entry is indexed by a fixed value chassis slotIndex of 2 (two) for all models."
INDEX { slotIndex }
::= { malwareCounterTable 1 }
MalwareCounterEntry ::= SEQUENCE {
malwareTotalQueriesSent
Counter32,
malwareUnresolvedQueriesQ
Counter32,
malwareTotalQueryResBelowMalTh
Counter32,
malwareTotalQueryResAboveMalTh
Counter32,
malwareBlocked
Counter32,
malwareTotalUDQueries
Counter32,
malwareUDDetected
Counter32,
malwareUDBlocked
Counter32,
malwareTempError
Counter32,
malwareProtocolError
Counter32,
malwareNoDomainError
Counter32,
malwareNoDataError
Counter32,
malwareOutOfMemoryError
Counter32,
malwareBadQueryError
Counter32,
malwareUnknownError
Counter32,
malwareFFPLastIncrTimeStamp
Counter32
}
malwareTotalQueriesSent OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of queries sent."
::= { malwareCounterEntry 1 }
malwareUnresolvedQueriesQ OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of unresolved queries(currently in queue)."
::= { malwareCounterEntry 2 }
malwareTotalQueryResBelowMalTh OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of query responses received below malware threshold(dirty)."
::= { malwareCounterEntry 3 }
malwareTotalQueryResAboveMalTh OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of query responses received above malware threshold(clean)."
::= { malwareCounterEntry 4 }
malwareBlocked OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of malwares blocked."
::= { malwareCounterEntry 5 }
malwareTotalUDQueries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of user-defined malware queries."
::= { malwareCounterEntry 6 }
malwareUDDetected OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of user-defined malware detected."
::= { malwareCounterEntry 7 }
malwareUDBlocked OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of user-defined malware blocked."
::= { malwareCounterEntry 8 }
malwareTempError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"temporary error, the resolver nameserver was not able to process our query or timed out."
::= { malwareCounterEntry 9 }
malwareProtocolError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"protocol error, a nameserver returned malformed reply."
::= { malwareCounterEntry 10 }
malwareNoDomainError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the domain name(implying md5 + mcafee.com) does not exist ."
::= { malwareCounterEntry 11 }
malwareNoDataError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"there is no data of requested type found. ."
::= { malwareCounterEntry 12 }
malwareOutOfMemoryError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"out of memory while processing request ."
::= { malwareCounterEntry 13 }
malwareBadQueryError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"some aspect of the query (most common is the domain name in question) is invalid, and the library can't even start a query."
::= { malwareCounterEntry 14 }
malwareUnknownError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"unknown error."
::= { malwareCounterEntry 15 }
malwareFFPLastIncrTimeStamp OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Malware FFP Last Successful Incremental Update Timestamp."
::= { malwareCounterEntry 16 }
--The layer2FwdStatsTable contains l2f counter information on the entity's
--interfaces.
--
layer2FwdStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Layer2FwdStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sensorCardPerfGrp 9 }
layer2FwdStatsEntry OBJECT-TYPE
SYNTAX Layer2FwdStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An interface entry containing layer2 forward statistics for each
object at their respective interface."
INDEX { slotIndex,
intfPortIndex }
::= { layer2FwdStatsTable 1 }
Layer2FwdStatsEntry ::= SEQUENCE {
layer2FwdCounter
Counter64
}
layer2FwdCounter OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter gives the number of packets that were sent out without
going through the sensor due to layer2 forward."
::= { layer2FwdStatsEntry 1 }
--
-- Sensor Pkt Count Table
--
sensorPktCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF SensorPktCountEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sensorCardPerfGrp 10 }
sensorPktCountEntry OBJECT-TYPE
SYNTAX SensorPktCountEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table give the sensor packet count related information.
This entry is indexed by a fixed value chassis slotIndex of 2 (two) for all models."
INDEX { slotIndex }
::= { sensorPktCountTable 1 }
SensorPktCountEntry ::= SEQUENCE {
unknownProtoPktsFwdCount
Counter64,
unknownProtoPktsFwdPercent
OCTET STRING,
unknownProtoPktsFwdLastTimestamp
INTEGER,
latencyPktsFwdPercent
OCTET STRING
}
unknownProtoPktsFwdCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of unknown protocol packets forwarded by the sensor without processing."
::= { sensorPktCountEntry 1 }
unknownProtoPktsFwdPercent OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(256))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of number of unknown protocol packets forwarded by the sensor without processing to total packets."
::= { sensorPktCountEntry 2 }
unknownProtoPktsFwdLastTimestamp OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"UTC Time at the sensor when the last unknown protocol packet was forwarded by the sensor without processing."
::= { sensorPktCountEntry 3 }
latencyPktsFwdPercent OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(256))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of number of latency packets forwarded by the sensor to total packets."
::= { sensorPktCountEntry 4 }
malwareStatsGrp OBJECT IDENTIFIER ::= { sensorCardPerfGrp 11 }
malwareEngineStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MalwareEngineStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
"
::= { malwareStatsGrp 1 }
malwareEngineStatsEntry OBJECT-TYPE
SYNTAX MalwareEngineStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry specified is indexed by <malware engine Id>.
Additonaly it contains the
"
INDEX { malwareEngineIndex }
::= { malwareEngineStatsTable 1 }
MalwareEngineStatsEntry ::= SEQUENCE {
malwareEngineIndex
INTEGER,
malwareStatsEngineName
DisplayString,
totalMalwareFilesProcessed
INTEGER,
numMalwareScoreClean
INTEGER,
numMalwareScoreVLow
INTEGER,
numMalwareScoreLow
INTEGER,
numMalwareScoreMedium
INTEGER,
numMalwareScoreHigh
INTEGER,
numMalwareScoreVHigh
INTEGER,
numMalwareAlertsSent
INTEGER,
numMalwareAttacksBlocked
INTEGER,
numMalwareTcpResetSent
INTEGER,
numMalwareScoreUnknown
INTEGER,
numMalwareFileSubmitted
INTEGER,
numMalwareFileIgnored
INTEGER,
numMalwareCacheReferences
INTEGER,
numMalwareStaticResponse
INTEGER,
numMalwareDynamicResponse
INTEGER,
numMalwareDropUnderLoad
INTEGER
}
malwareEngineIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Malware engine index"
::= { malwareEngineStatsEntry 1 }
malwareStatsEngineName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..256))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the malware engine name string."
::= { malwareEngineStatsEntry 2 }
totalMalwareFilesProcessed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the total number of malware files processed by the specific malware engine. "
::= { malwareEngineStatsEntry 3 }
numMalwareScoreClean OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of clean malware files processed by the specific malware engine."
::= { malwareEngineStatsEntry 4 }
numMalwareScoreVLow OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware alerts generated by the specific malware engine and having malware score as very low."
::= { malwareEngineStatsEntry 5 }
numMalwareScoreLow OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware alerts generated by the specific malware engine and having malware score as low."
::= { malwareEngineStatsEntry 6 }
numMalwareScoreMedium OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware alerts generated by the specific malware engine and having malware score as medium. "
::= { malwareEngineStatsEntry 7 }
numMalwareScoreHigh OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware alerts generated by the specific malware engine and having malware score as high."
::= { malwareEngineStatsEntry 8 }
numMalwareScoreVHigh OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware alerts generated by the specific malware engine and having malware score as very high."
::= { malwareEngineStatsEntry 9 }
numMalwareAlertsSent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware alerts sent to NSM, by the sensor for the specific malware engine."
::= { malwareEngineStatsEntry 10 }
numMalwareAttacksBlocked OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware attacks blocked by the sensor for the specific malware engine. "
::= { malwareEngineStatsEntry 11 }
numMalwareTcpResetSent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware TCP Resets sent by the sensor for the specific malware engine."
::= { malwareEngineStatsEntry 12 }
numMalwareScoreUnknown OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware alerts generated by the specific malware engine and having malware score as unknown."
::= { malwareEngineStatsEntry 13 }
numMalwareFileSubmitted OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware files submitted to any of the malware engine."
::= { malwareEngineStatsEntry 14 }
numMalwareFileIgnored OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware files submitted to the malware engine but not being processed by that malware engine."
::= { malwareEngineStatsEntry 15 }
numMalwareCacheReferences OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware results obtained from cache."
::= { malwareEngineStatsEntry 16 }
numMalwareStaticResponse OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware responses obtained from ATD using static analysis"
::= { malwareEngineStatsEntry 17 }
numMalwareDynamicResponse OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware responses obtained from ATD based on dynamic analysis within ATD"
::= { malwareEngineStatsEntry 18 }
numMalwareDropUnderLoad OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware files dropped i.e not being inspected because of load."
::= { malwareEngineStatsEntry 19 }
malwareFileStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MalwareFileStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
"
::= { malwareStatsGrp 2 }
malwareFileStatsEntry OBJECT-TYPE
SYNTAX MalwareFileStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry specified is indexed by <malware file type index>.
"
INDEX { malwareFileTypeIndex }
::= { malwareFileStatsTable 1 }
MalwareFileStatsEntry ::= SEQUENCE {
malwareFileTypeIndex
INTEGER,
malwareFileTypeName
DisplayString,
numMalwareFilesProcessed
INTEGER
}
malwareFileTypeIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"malware file type index."
::= { malwareFileStatsEntry 1 }
malwareFileTypeName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..256))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the file type name string."
::= { malwareFileStatsEntry 2 }
numMalwareFilesProcessed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of malware file processed of the specific file type."
::= { malwareFileStatsEntry 3 }
malwareStatsClearCounters OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configuration option to reset malware statistics counters through SNMP. Default: false (2)"
::= { malwareStatsGrp 3 }
malwareRESTStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MalwareRESTStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Error Counters of GTI File Reputation REST feature
"
::= { malwareStatsGrp 4 }
malwareRESTStatsEntry OBJECT-TYPE
SYNTAX MalwareRESTStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"
Error Counters of GTI File Reputation REST feature
"
INDEX { malwareEngineIndex }
::= { malwareRESTStatsTable 1 }
MalwareRESTStatsEntry ::= SEQUENCE {
malwareRESTEngineName
DisplayString,
numMalwareInternalServerError
INTEGER,
numMalwareInvalidJSON
INTEGER,
numMalwareUnsupportedOperation
INTEGER,
numMalwareMissingMandatoryParam
INTEGER,
numMalwareIncorrectProtocalFormat
INTEGER,
numMalwareMaxOperationExceeded
INTEGER,
numMalwareInvalidProtocalVersion
INTEGER,
numMalwareDuplicateParameter
INTEGER,
numMalwareMissingCIInfo
INTEGER,
numMalwareMandatoryParamEmpty
INTEGER,
numMalwareInvalidMandatoryParamFormat
INTEGER,
numMalwareFailedToConnect
INTEGER,
numMalwareEmptyInput
INTEGER,
numMalwareEmptyCIParam
INTEGER,
numMalwareInvalidCIParamFormat
INTEGER,
numMalwareDuplicateCIParam
INTEGER,
numMalwareGenericServerError
INTEGER,
numMalwareOtherError
INTEGER,
numMalwarePreSubmitError
INTEGER,
numMalwareCurlFailed
INTEGER,
numMalwareHttpBadRequest
INTEGER,
numMalwareHttpUnauthorized
INTEGER,
numMalwareHttpUnsupportedMedia
INTEGER,
numMalwareHttpUnknownError
INTEGER,
numMalwareJsonParseError
INTEGER,
numMalwareHashNotFound
INTEGER
}
malwareRESTEngineName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..256))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the indexed malware engine name"
::= { malwareRESTStatsEntry 1 }
numMalwareInternalServerError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Internal GTI Server error"
::= { malwareRESTStatsEntry 2 }
numMalwareInvalidJSON OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Invalid JSON format Error"
::= { malwareRESTStatsEntry 3 }
numMalwareUnsupportedOperation OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Unsupported Operation Error"
::= { malwareRESTStatsEntry 4 }
numMalwareMissingMandatoryParam OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Missing mandatory parameter Error"
::= { malwareRESTStatsEntry 5 }
numMalwareIncorrectProtocalFormat OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Incorrect GTI protocol format Error"
::= { malwareRESTStatsEntry 6 }
numMalwareMaxOperationExceeded OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Max number of operations exceeded"
::= { malwareRESTStatsEntry 7 }
numMalwareInvalidProtocalVersion OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Invalid protocol version Error"
::= { malwareRESTStatsEntry 8 }
numMalwareDuplicateParameter OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Duplicate parameter Error"
::= { malwareRESTStatsEntry 9 }
numMalwareMissingCIInfo OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Missing mandatory client information parameter Error"
::= { malwareRESTStatsEntry 10 }
numMalwareMandatoryParamEmpty OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Empty mandatory parameter Error"
::= { malwareRESTStatsEntry 11 }
numMalwareInvalidMandatoryParamFormat OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Invalid mandatory parameter format Error"
::= { malwareRESTStatsEntry 12 }
numMalwareFailedToConnect OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Failed to obtain a Connection Error"
::= { malwareRESTStatsEntry 13 }
numMalwareEmptyInput OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Empty Input Error"
::= { malwareRESTStatsEntry 14 }
numMalwareEmptyCIParam OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Empty client information parameter Error"
::= { malwareRESTStatsEntry 15 }
numMalwareInvalidCIParamFormat OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Invalid client information parameter format Error"
::= { malwareRESTStatsEntry 16 }
numMalwareDuplicateCIParam OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Duplicate client information parameter Error"
::= { malwareRESTStatsEntry 17 }
numMalwareGenericServerError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Generic GTI Server error"
::= { malwareRESTStatsEntry 18 }
numMalwareOtherError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of other GTI Server Error"
::= { malwareRESTStatsEntry 19 }
numMalwarePreSubmitError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of error while creating REST query"
::= { malwareRESTStatsEntry 20 }
numMalwareCurlFailed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of CURL perform failed"
::= { malwareRESTStatsEntry 21 }
numMalwareHttpBadRequest OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of HTTP 400 Errors"
::= { malwareRESTStatsEntry 22 }
numMalwareHttpUnauthorized OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of HTTP 401 Errors"
::= { malwareRESTStatsEntry 23 }
numMalwareHttpUnsupportedMedia OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of HTTP 415 Errors"
::= { malwareRESTStatsEntry 24 }
numMalwareHttpUnknownError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of other HTTP Errors"
::= { malwareRESTStatsEntry 25 }
numMalwareJsonParseError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Errors while parsing JSON response object"
::= { malwareRESTStatsEntry 26 }
numMalwareHashNotFound OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Total Number of Hash is not found in GTI server"
::= { malwareRESTStatsEntry 27 }
advancedBotnetStatsGrp OBJECT IDENTIFIER ::= { sensorCardPerfGrp 12 }
callBackDetected OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This objects returns the number alerts pertaining to callback detector matches."
::= { advancedBotnetStatsGrp 1 }
dgaZombieDetected OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of alerts with respect to DGA zombies detected."
::= { advancedBotnetStatsGrp 2 }
dgaCnCServerDetected OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of alert pertaining to the CnC(command and control) server suspect detected."
::= { advancedBotnetStatsGrp 3 }
dgaConectionToCnCServerDetected OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of alert pertaining to the CnC(command and control) and DGA zombie callback detected"
::= { advancedBotnetStatsGrp 4 }
fastFluxDnsDetected OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of alerts pertaining to IP flux botnet activity detected."
::= { advancedBotnetStatsGrp 5 }
fastFluxAgentConnectionDetected OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of alerts pertaining to IP flux agent call back detected"
::= { advancedBotnetStatsGrp 6 }
zeroDayBotnetDetected OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of alerts pertaining to Other zero day botnet detected"
::= { advancedBotnetStatsGrp 7 }
knownBotnetDetected OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns the number of alerts pertaining to known botnets detected."
::= { advancedBotnetStatsGrp 8 }
sensorIntfStatGrp OBJECT IDENTIFIER ::= { sensorCardPerfGrp 13 }
sensorTotalPktsRecv OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of packets that sensor has
recieved."
::= { sensorIntfStatGrp 1 }
sensorTotalUnicastPktsRecv OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of unicast packets that sensor has
recieved."
::= { sensorIntfStatGrp 2 }
sensorTotalMulticastPktsRecv OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of multicast packets that sensor
has recieved."
::= { sensorIntfStatGrp 3 }
sensorTotalBroadcastPktsRecv OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of unicast packets that sensor has
recieved."
::= { sensorIntfStatGrp 4 }
sensorTotalBytesRecv OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of bytes that sensor has recieved."
::= { sensorIntfStatGrp 5 }
sensorTotalCRCErrorsRecv OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of packets received with bad CRC and bad
alignment in sensor."
::= { sensorIntfStatGrp 6 }
sensorTotalPktsSent OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of packets that have been sent on sensor."
::= { sensorIntfStatGrp 7 }
sensorTotalUnicastPktsSent OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of unicast packets that have been sent on
sensor."
::= { sensorIntfStatGrp 8 }
sensorTotalMulticastPktsSent OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of multicast packets that have been sent on
sensor."
::= { sensorIntfStatGrp 9 }
sensorTotalBroadcastPktsSent OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of broadcast packets that have been sent on
sensor."
::= { sensorIntfStatGrp 10 }
sensorTotalBytesSent OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of bytes that have been sent on sensor."
::= { sensorIntfStatGrp 11 }
sensorTotalCRCErrorsSent OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of packets that have been sent with bad CRC on sensor."
::= { sensorIntfStatGrp 12 }
sensorIntfResetCounters OBJECT-TYPE
SYNTAX INTEGER {
reset(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Resets the counters in sensor interface stats table"
::= { sensorIntfStatGrp 13 }
sensorNbadFlowRecordCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total count of flow records generated by the sensor."
::= { sensorIntfStatGrp 14 }
--
-- This group contains MIB objects applicable for SSL statistics
--
sslStatisticsGrp OBJECT IDENTIFIER ::= { sensorCardPerfGrp 14}
-- This group consists of scalar for ssl statistics
sslCounterGrp OBJECT IDENTIFIER ::= { sslStatisticsGrp 1}
outboundsslConnectionAttemptsClientToSensor OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of ssl connections attempt from client to sensor in outbound direction"
::= { sslCounterGrp 1 }
outboundsslConnectionAttemptsSensorToServer OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of ssl connections attempt from sensor to external server in outbound direction"
::= { sslCounterGrp 2 }
outboundsslEndToEndSslHandshakeInProgress OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of ssl handshake in progress for outbound direction"
::= { sslCounterGrp 3 }
outboundsslEndToEndSslFlowsEstablished OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of ssl flows established for outbound direction"
::= { sslCounterGrp 4 }
outboundsslWhitelistedFlows OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of ssl flows being whitelisted for outbound direction"
::= { sslCounterGrp 5 }
outboundsslAttacksDetected OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of attacks detected in ssl packets in outbound direction"
::= { sslCounterGrp 6 }
outboundsslTotalRSAFlows OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of flows seen with RSA key exchange in outbound direction"
::= { sslCounterGrp 7 }
outboundsslTotalDHFlows OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of flows seen with Diffie Hellman key exchange in outbound direction"
::= { sslCounterGrp 8 }
outboundsslTotalNonSslFlows OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of non ssl flows seen in outbound direction"
::= { sslCounterGrp 9 }
outboundsslUntrustedCertCounts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of untrusted certificates seen in outbound direction"
::= { sslCounterGrp 10 }
outboundsslUntrustedCertFlowsBlockOrSkipped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of ssl flows blocked or skipped due to untrusted certificates seen in outbound direction"
::= { sslCounterGrp 11 }
outboundsslUnknownCertCounts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of unknown certificates seen in outbound direction"
::= { sslCounterGrp 12 }
outboundsslUnknownCertFlowsBlockOrSkipped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of ssl flows blocked or skipped due to unknown validity of certificates seen in outbound direction"
::= { sslCounterGrp 13 }
outboundsslUnsupportedCipherSuiteFlowsBlockedOrSkipped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of ssl flows blocked or skipped due to unsupported cipher suite in outbound direction"
::= { sslCounterGrp 14 }
outboundsslGeneralDecryptionFailureFlowsBlockOrSkipped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of ssl flows blocked or skipped due to general decryption failure in outbound direction"
::= { sslCounterGrp 15 }
sslEventConnectionRecycled OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of connections ran out of ssl connection structure but was able to prematurely retire one that has not been recently used. To prevent this increase SSL connection count in the NSM."
::= { sslCounterGrp 16 }
sslEventConnectionExhausted OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of connection for which the sensor could not allocate a new SSL connection structure because all SSL connection structures were in use. To resolve this increase SSL connection count in the NSM."
::= { sslCounterGrp 17 }
sslEventPacketsWithNoConnection OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of SSL packets received that did not have a corresponding SSL structure."
::= { sslCounterGrp 18 }
sslEventSessionAllocationError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sensor could not allocate new SSL session structure because all SSL session resource were in use. This indicates more simultaneous SSL sessions were in use than the sensor was configured to processs. To resolve this, increase the SSL connection count or decrease the SSL cache time on the NSM"
::= { sslCounterGrp 19 }
sslEventUnsupportedDiffieHellmanCipherSuite OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A cipher suite that uses Diffie-Hellman was negotiated. The sensor will not be able to detect attacks in this SSL connection. Configure the server to only allow cipher suites that use RSA"
::= { sslCounterGrp 20 }
sslEventUnsupportedExportCipher OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total connection that used SSLv3/TLS export cipher was negotiated, which the sensor cannot decrypt due to the use of ephemeral RSA"
::= { sslCounterGrp 21 }
sslEventUnsupportedOrUnknownCipher OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total connection where cipher was negotiated that the Sensor cannot decrypt."
::= { sslCounterGrp 22 }
sslMisMatchedCertCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the total number of certificates seen in the traffic which did not matched any of the server certificate"
::= { sslCounterGrp 23 }
sslStatsResetCounters OBJECT-TYPE
SYNTAX INTEGER {
reset (0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset all the ssl statistics counters"
::= { sslCounterGrp 24 }
sslEventConnectionKeyMatched OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total connection where cipher was negotiated and the Master Secret lookup returned a match"
::= { sslCounterGrp 28 }
-- This table contains entries for certs matches
sslCertsCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF SslCertsCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing cert match details"
::= { sslStatisticsGrp 2}
sslCertsCounterEntry OBJECT-TYPE
SYNTAX SslCertsCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This MIB object contains all the attributes that are specific to the L2 fwd entry for TCP table. Indexed by intfPortLinearIndex and entry number."
INDEX { certEntryIndex }
::= { sslCertsCounterTable 1 }
SslCertsCounterEntry ::= SEQUENCE {
certEntryIndex
INTEGER,
sslCertId
INTEGER,
sslCertAlias
DisplayString,
sslCertMatchCount
Counter32
}
certEntryIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is certificate entry index"
::= { sslCertsCounterEntry 1 }
sslCertId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is certificate Id"
::= { sslCertsCounterEntry 2 }
sslCertAlias OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is certificate alias name"
::= { sslCertsCounterEntry 3 }
sslCertMatchCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is total number of flows matching the certificate"
::= { sslCertsCounterEntry 4 }
sensorPacketDropGrp OBJECT IDENTIFIER ::= { ivSensorPerformanceMIB 2 }
sensorPktDropTable OBJECT-TYPE
SYNTAX SEQUENCE OF SensorPktDropEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table containing packets dropped at sensor level under various categories"
::= { sensorPacketDropGrp 1 }
sensorPktDropEntry OBJECT-TYPE
SYNTAX SensorPktDropEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry is indexed by a fixed value chassis slotIndex of 2 (two) for all models."
INDEX { slotIndex }
::= { sensorPktDropTable 1 }
SensorPktDropEntry ::= SEQUENCE {
rateLimitPktDrop
Counter32,
ipPktSanityChkDrop
Counter32,
ipv6PktSanityChkDrop
Counter32,
sensorPktDropResetCounters
INTEGER
}
rateLimitPktDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to sensor rate limiting"
::= { sensorPktDropEntry 1 }
ipPktSanityChkDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to IPV4 sanity check failure"
::= { sensorPktDropEntry 2 }
ipv6PktSanityChkDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to IPV6 sanity check failure"
::= { sensorPktDropEntry 3 }
sensorPktDropResetCounters OBJECT-TYPE
SYNTAX INTEGER {
reset(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Resets the counters in sensor packet drop table"
::= { sensorPktDropEntry 4 }
intfPortPktDropTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntfPortPktDropEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to maintain sensor interface level packet drop statistics"
::= { sensorPacketDropGrp 2 }
intfPortPktDropEntry OBJECT-TYPE
SYNTAX IntfPortPktDropEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An interface entry that maintains the dropped packet statistics for various categories"
INDEX { slotIndex,
intfPortIndex }
::= { intfPortPktDropTable 1 }
IntfPortPktDropEntry ::= SEQUENCE {
intfPortIpChksumErrorDrop
Counter32,
intfPortTcpChksumErrorDrop
Counter32,
intfPortUdpChksumErrorDrop
Counter32,
intfPortIcmpChksumErrorDrop
Counter32,
intfPortIcmpv6ChksumErrorDrop
Counter32,
intfPortAclDrop
Counter32,
intfPortBadPacketDrop
Counter32,
intfPortColdStartPacketDrop
Counter32,
intfPortAttackPacketDrop
Counter32,
intfPortIpReassemTimeoutDrop
Counter32,
intfPortIpv6ReassemTimeoutDrop
Counter32,
intfPortTcpOutOfOrderTimeoutDrop
Counter32,
intfPortTcpProtoErrorDrop
Counter32,
intfPortUdpProtoErrorDrop
Counter32,
intfPortIcmpProtoErrorDrop
Counter32,
intfPortIcmpv6ProtoErrorDrop
Counter32,
intfPortIpProtoErrorDrop
Counter32,
intfPortIpv6ProtoErrorDrop
Counter32,
intfPortCRCErrorDrop
Counter32,
intfPortOtherLayer2ErrorDrop
Counter32,
intfPortOffHdrLenErrorDrop
Counter32,
intfPortSysOutOfResourceDrop
Counter32,
intfPortPktDropResetCounters
INTEGER,
intfPortHostIsolationv4Drop
Counter32,
intfPortHostIsolationv6Drop
Counter32,
intfPortLayer2MiscDrop
Counter32
}
intfPortIpChksumErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to incorrect IP checksum"
::= { intfPortPktDropEntry 1 }
intfPortTcpChksumErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to incorrect TCP checksum"
::= { intfPortPktDropEntry 2 }
intfPortUdpChksumErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to incorrect UDP checksum"
::= { intfPortPktDropEntry 3 }
intfPortIcmpChksumErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to incorrect ICMP v4 checksum"
::= { intfPortPktDropEntry 4 }
intfPortIcmpv6ChksumErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to incorrect ICMP v6 checksum"
::= { intfPortPktDropEntry 5 }
intfPortAclDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to configured ACL Rules"
::= { intfPortPktDropEntry 6 }
intfPortBadPacketDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to non-existence of a valid flow"
::= { intfPortPktDropEntry 7 }
intfPortColdStartPacketDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to cold start packet drop action"
::= { intfPortPktDropEntry 8 }
intfPortAttackPacketDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number packets dropped due to recommended/configured attack response action"
::= { intfPortPktDropEntry 9 }
intfPortIpReassemTimeoutDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to IPV4 fragment reassembly timeout"
::= { intfPortPktDropEntry 10 }
intfPortIpv6ReassemTimeoutDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to IPV6 fragment reassembly timeout"
::= { intfPortPktDropEntry 11 }
intfPortTcpOutOfOrderTimeoutDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to TCP out of order reassembly timeout"
::= { intfPortPktDropEntry 12 }
intfPortTcpProtoErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in TCP Protocol"
::= { intfPortPktDropEntry 13 }
intfPortUdpProtoErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in UDP Protocol"
::= { intfPortPktDropEntry 14 }
intfPortIcmpProtoErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in ICMP v4 Protocol"
::= { intfPortPktDropEntry 15 }
intfPortIcmpv6ProtoErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in ICMP v6 Protocol"
::= { intfPortPktDropEntry 16 }
intfPortIpProtoErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in IPv4 protocol"
::= { intfPortPktDropEntry 17 }
intfPortIpv6ProtoErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in IPv6 protocol"
::= { intfPortPktDropEntry 18 }
intfPortCRCErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number packets dropped to CRC check failures"
::= { intfPortPktDropEntry 19 }
intfPortOtherLayer2ErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to other Layer2 errors"
::= { intfPortPktDropEntry 20 }
intfPortOffHdrLenErrorDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to offset index length errors"
::= { intfPortPktDropEntry 21 }
intfPortSysOutOfResourceDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to sensor running out of resource"
::= { intfPortPktDropEntry 22 }
intfPortPktDropResetCounters OBJECT-TYPE
SYNTAX INTEGER {
reset(0),
reset-ratelimit-stats(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For a value reset(0), resets the counters in this interface port level table.
For a value reset-ratelimit-stats(1), resets all the queue-level ratelimit
counters over this port."
::= { intfPortPktDropEntry 23 }
intfPortHostIsolationv4Drop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of IPv4 packets dropped due to host isolation configuration"
::= { intfPortPktDropEntry 24 }
intfPortHostIsolationv6Drop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of IPv6 packets dropped due to host isolation configuration"
::= { intfPortPktDropEntry 25 }
intfPortLayer2MiscDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of non-error packets received on monitoring ports dropped in the layer2 switch because of other reasons"
::= { intfPortPktDropEntry 26 }
intfPortQRateLimitDropTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntfPortQRateLimitDropEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table to maintain sensor interface and queue level rate-limit drop statistics"
::= { sensorPacketDropGrp 3 }
intfPortQRateLimitDropEntry OBJECT-TYPE
SYNTAX IntfPortQRateLimitDropEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An interface queue entry that maintains the dropped packet statistics for various categories"
INDEX { slotIndex,
intfPortIndex,
rateLimitQueueIndex }
::= { intfPortQRateLimitDropTable 1 }
IntfPortQRateLimitDropEntry ::= SEQUENCE {
intfPortQRateLimitBandwidth
Counter32,
intfPortQRateLimitBytesDrop
Counter32,
intfPortQRateLimitPktsDrop
Counter32,
intfPortQRateLimitDropResetCounters
INTEGER
}
intfPortQRateLimitBandwidth OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter gives the configured ratelimit bandwidth in bytes, for the specified port and queue indicies."
::= { intfPortQRateLimitDropEntry 1 }
intfPortQRateLimitBytesDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter gives the actual ratelimit bytes dropped for the specified port and queue indicies."
::= { intfPortQRateLimitDropEntry 2 }
intfPortQRateLimitPktsDrop OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter gives the actual ratelimit packets dropped for the specified port and queue indicies."
::= { intfPortQRateLimitDropEntry 3 }
intfPortQRateLimitDropResetCounters OBJECT-TYPE
SYNTAX INTEGER {
reset(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This counter resets the rateLimit drop counter of the specified port and queue indicies."
::= { intfPortQRateLimitDropEntry 4 }
sensorPacketDropStatGrp OBJECT IDENTIFIER ::= { sensorPacketDropGrp 4}
sensorIpChksumErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to incorrect IP checksum by the sensor."
::= { sensorPacketDropStatGrp 1 }
sensorTcpChksumErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to incorrect TCP checksum by the sensor."
::= { sensorPacketDropStatGrp 2 }
sensorUdpChksumErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to incorrect UDP checksum by the sensor."
::= { sensorPacketDropStatGrp 3 }
sensorIcmpChksumErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to incorrect ICMP v4 checksum by the sensor."
::= { sensorPacketDropStatGrp 4 }
sensorIcmpv6ChksumErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to incorrect ICMP v6 checksum by the sensor."
::= { sensorPacketDropStatGrp 5 }
sensorAclDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to configured ACL Rules by the sensor."
::= { sensorPacketDropStatGrp 6 }
sensorBadPacketDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to non-existence of a valid flow by the sensor."
::= { sensorPacketDropStatGrp 7 }
sensorColdStartPacketDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to cold start packet drop action by the sensor."
::= { sensorPacketDropStatGrp 8 }
sensorAttackPacketDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number packets dropped due to recommended/configured attack response action by the sensor."
::= { sensorPacketDropStatGrp 9 }
sensorIpReassemTimeoutDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to IPV4 fragment reassembly timeout by the sensor."
::= { sensorPacketDropStatGrp 10 }
sensorIpv6ReassemTimeoutDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to IPV6 fragment reassembly timeout by the sensor."
::= { sensorPacketDropStatGrp 11 }
sensorTcpOutOfOrderTimeoutDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to TCP out of order reassembly timeout by the sensor."
::= { sensorPacketDropStatGrp 12 }
sensorTcpProtoErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in TCP Protocol by the sensor."
::= { sensorPacketDropStatGrp 13 }
sensorUdpProtoErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in UDP Protocol by the sensor."
::= { sensorPacketDropStatGrp 14 }
sensorIcmpProtoErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in ICMP v4 Protocol by the sensor."
::= { sensorPacketDropStatGrp 15 }
sensorIcmpv6ProtoErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in ICMP v6 Protocol by the sensor."
::= { sensorPacketDropStatGrp 16 }
sensorIpProtoErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in IPv4 protocol by the sensor."
::= { sensorPacketDropStatGrp 17 }
sensorIpv6ProtoErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to errors in IPv6 protocol by the sensor."
::= { sensorPacketDropStatGrp 18 }
sensorCRCErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number packets dropped to CRC check failures by the sensor."
::= { sensorPacketDropStatGrp 19 }
sensorOtherLayer2ErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to other Layer2 errors by the sensor."
::= { sensorPacketDropStatGrp 20 }
sensorOffHdrLenErrorDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to offset index length errors by the sensor."
::= { sensorPacketDropStatGrp 21 }
sensorSysOutOfResourceDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped due to sensor running out of resource by the sensor."
::= { sensorPacketDropStatGrp 22 }
sensorPktDropStatResetCounters OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Resets the counters in sensor packet drop table"
::= { sensorPacketDropStatGrp 23 }
sensorHostIsolationv4Drop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of IPv4 packets dropped due to host isolation configuration by the sensor."
::= { sensorPacketDropStatGrp 24 }
sensorHostIsolationv6Drop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of IPv6 packets dropped due to host isolation configuration by the sensor."
::= { sensorPacketDropStatGrp 25 }
sensorLayer2BackplaneDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets dropped on the uplink ports of layer2 switch"
::= { sensorPacketDropStatGrp 26 }
sensorLayer2MiscDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of non-error packets received on all monitoring ports dropped in the layer2 switch because of other reasons"
::= { sensorPacketDropStatGrp 27 }
sensorNICDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packet dropped at NIC level"
::= { sensorPacketDropStatGrp 28 }
sensorFrontEndMiscDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packet dropped at Frontend level"
::= { sensorPacketDropStatGrp 29 }
sensorBackEndMiscDrop OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of Misc packet dropped at Backend level"
::= { sensorPacketDropStatGrp 30 }
pktCapStatGrp OBJECT IDENTIFIER ::= { ivSensorPerformanceMIB 3 }
pktCapTotal OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of Packet Capture"
::= {pktCapStatGrp 1 }
pktCapDropTotal OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Packet drops due to sensor load/port load."
::= {pktCapStatGrp 2 }
controlPathPerfGrp OBJECT IDENTIFIER ::= { ivSensorPerformanceMIB 4 }
controlPathMemUsageTable OBJECT-TYPE
SYNTAX SEQUENCE OF ControlPathMemUsageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { controlPathPerfGrp 1 }
controlPathMemUsageEntry OBJECT-TYPE
SYNTAX ControlPathMemUsageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry gives information about the Control path memory utilized.
This entry is indexed by a fixed value chassis slotIndex of 1 (one) for all models."
INDEX { slotIndex }
::= { controlPathMemUsageTable 1 }
ControlPathMemUsageEntry ::= SEQUENCE {
sysMemFree
Counter,
sysMemCached
Counter,
sysMemBuffers
Counter,
sysMemUtilisation
Counter
}
sysMemFree OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Control Path system free memory available in MB"
::= {controlPathMemUsageEntry 1 }
sysMemCached OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Control Path system cached memory in MB"
::= {controlPathMemUsageEntry 2 }
sysMemBuffers OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Control Path system buffer memory in MB"
::= {controlPathMemUsageEntry 3 }
sysMemUtilisation OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Control Path system memory utilisation in percentage"
::= {controlPathMemUsageEntry 4 }