mibs/MIBS/ubiquoss/UBQS-AFSMGR-MIB

1025 lines
38 KiB
Plaintext
Raw Permalink Normal View History

2023-12-05 12:25:34 +01:00
--
-- UBQS-AFSMGR-MIB.my
-- MIB generated by MG-SOFT Visual MIB Builder Version 3.0 Build 271
-- Monday, April 12, 2010
--
UBQS-AFSMGR-MIB DEFINITIONS ::= BEGIN
IMPORTS
sysObjectID, sysContact, sysName, sysLocation, ifIndex
FROM RFC1213-MIB
IpAddress, Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, RowStatus
FROM SNMPv2-TC
ubiMgmtv2
FROM UBQS-SMI;
ubiAFSMGREventMIB MODULE-IDENTITY
LAST-UPDATED "201004120000Z"
ORGANIZATION "Ubiquoss Corp."
CONTACT-INFO
" Ubiquoss
Customer Service
Postal: 24F Milennium B/D,
467-12, Dogok-Dong,
GangNam-Gu, Seoul 135-270
Korea
Tel: 82-2-2190-3100"
DESCRIPTION
"AFSMGR Event Group"
::= { ubiMgmtv2 7 }
--
-- Node definitions
--
-- 1.3.6.1.4.1.236.4.1.7.2.1
currentAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF CurrentAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { ubiAFSMGREventMIB 1 }
-- 1.3.6.1.4.1.236.4.1.7.2.1.1
currentAlarmEntry OBJECT-TYPE
SYNTAX CurrentAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { AlarmIndex }
::= { currentAlarmTable 1 }
CurrentAlarmEntry ::=
SEQUENCE {
alarmIndex
Integer32,
alarmId
DisplayString,
alarmType
INTEGER,
alarmSeverity
INTEGER,
alarmPhysicalLoc
DisplayString,
alarmLogicalLoc
DisplayString,
alarmCurStatus
Integer32,
alarmAuxinfo
DisplayString,
alarmDateTime
DisplayString,
alarmStatus
Integer32
}
alarmIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"current Alarm index."
::= { currentAlarmEntry 1 }
alarmId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { currentAlarmEntry 2 }
alarmType OBJECT-TYPE
SYNTAX INTEGER
{
equipment(1),
communications(2),
qos(3),
processing(4),
environment(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description
1 : equipment
2 : communications
3 : QoS
4 : processing
5 : environment
"
::= { currentAlarmEntry 3 }
alarmSeverity OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
warning(4),
indeterminate(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description
1 : critical
2 : major
3 : minor
4 : warning
5 : indeterminate
"
::= { currentAlarmEntry 4 }
alarmPhysicalLoc OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { currentAlarmEntry 5 }
alarmLogicalLoc OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { currentAlarmEntry 6 }
alarmCurStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { currentAlarmEntry 7 }
alarmAuxinfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { currentAlarmEntry 8 }
alarmDateTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { currentAlarmEntry 9 }
alarmStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { currentAlarmEntry 10 }
--
-- eventLogTable
--
eventLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { ubiAFSMGREventMIB 2 }
eventLogEntry OBJECT-TYPE
SYNTAX EventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { EventIndex }
::= { eventLogTable 1 }
EventLogEntry ::=
SEQUENCE {
eventIndex
Integer32,
eventId
DisplayString,
eventType
INTEGER,
eventSeverity
INTEGER,
eventValue
DisplayString,
eventDateTime
DisplayString,
eventStatus
Integer32
}
eventIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { eventLogEntry 1 }
eventId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { eventLogEntry 2 }
eventType OBJECT-TYPE
SYNTAX INTEGER
{
equipment(1),
communications(2),
qos(3),
processing(4),
environment(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description
1 : equipment
2 : communications
3 : QoS
4 : processing
5 : environment
"
::= { eventLogEntry 3 }
eventSeverity OBJECT-TYPE
SYNTAX INTEGER
{
critical(1),
major(2),
minor(3),
warning(4),
indeterminate(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description
1 : critical
2 : major
3 : minor
4 : warning
5 : indeterminate
"
::= { eventLogEntry 4 }
eventValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { eventLogEntry 5 }
eventDateTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { eventLogEntry 6 }
eventStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description"
::= { eventLogEntry 7 }
--
-- afsmgrEventManagerTrap
--
afsmgrEventManagerTrap OBJECT IDENTIFIER ::= { ubiAFSMGREventMIB 3 }
sysWarmStartNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"System Warm-Start Notification."
::= { afsmgrEventManagerTrap 1 }
sysColdStartNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"System Cold-Start Notification."
::= { afsmgrEventManagerTrap 2 }
linkUpNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Link Up Notification."
::= { afsmgrEventManagerTrap 3 }
linkDownNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Link Down Notification."
::= { afsmgrEventManagerTrap 4 }
cpuOverloadFallingNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"CPU Overload Falling Notification."
::= { afsmgrEventManagerTrap 5 }
cpuOverloadRisingNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"CPU Overload Rising Notification."
::= { afsmgrEventManagerTrap 6 }
gbicOperNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Gbic Equip/Unequip Operation Notification."
::= { afsmgrEventManagerTrap 7 }
memoryOverloadNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Memory Overload Notification."
::= { afsmgrEventManagerTrap 8 }
slotOperNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Slot Equip/Unequip Operation Notification."
::= { afsmgrEventManagerTrap 9 }
tempLowNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Temperature Low Alarm Notification."
::= { afsmgrEventManagerTrap 10 }
tempHighNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Temperature High Alarm Notification."
::= { afsmgrEventManagerTrap 11 }
fanAlarmNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Fan Alarm Notification."
::= { afsmgrEventManagerTrap 12 }
fmuEquipStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Fan Module Unit Equip/Unequip Status Notification."
::= { afsmgrEventManagerTrap 13 }
psuAlarmNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Power Alarm Notification."
::= { afsmgrEventManagerTrap 14 }
psuEquipStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Power Supply Unit Equip/Unequip Status Notification."
::= { afsmgrEventManagerTrap 15 }
portAdminNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Port Administration Status Notification."
::= { afsmgrEventManagerTrap 16 }
fanOperStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Fan Operational Status Notification."
::= { afsmgrEventManagerTrap 17 }
rmonRisingNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Rmon Rising Notification."
::= { afsmgrEventManagerTrap 18 }
rmonFallingNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Rmon Falling Notification."
::= { afsmgrEventManagerTrap 19 }
portSLDNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Port Self-Loop Detection Notification."
::= { afsmgrEventManagerTrap 20 }
remoteConnection NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Remote connection Notification."
::= { afsmgrEventManagerTrap 30 }
ponDriftWindowNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Onu Drift Window Notification."
::= { afsmgrEventManagerTrap 41 }
ponGemChannelLossNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Loss of GEM channel delineation Notification."
::= { afsmgrEventManagerTrap 42 }
ponAckLossNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Loss of acknowledge with ONUi Notification."
::= { afsmgrEventManagerTrap 43 }
ponSigDegradeNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Signal Degraded of ONUi Notification."
::= { afsmgrEventManagerTrap 44 }
ponSigFailNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Signal Fail of ONUi Notification."
::= { afsmgrEventManagerTrap 45 }
ponPhysEquipErrNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Physical Equipment Error of ONUi Notification."
::= { afsmgrEventManagerTrap 46 }
ponKeySyncLossNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Loss of Key sync with ONUi Notification."
::= { afsmgrEventManagerTrap 47 }
ponTransIfWarmNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Transmission Interference Warning Notification."
::= { afsmgrEventManagerTrap 48 }
ponTransIfAlarmNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Transmission Interference Alarm Notification."
::= { afsmgrEventManagerTrap 49 }
ponRemoDefectIndNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Remote Defect Indication of ONUi Notification."
::= { afsmgrEventManagerTrap 50 }
onuOperStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Onu Operation Status Notification."
::= { afsmgrEventManagerTrap 51 }
oltAlarmNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Olt Alarm Notification."
::= { afsmgrEventManagerTrap 52 }
oltLinkFaultNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Olt Link Fault Notification."
::= { afsmgrEventManagerTrap 53 }
ontDyingGaspNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Ont Dying Gasp Notification."
::= { afsmgrEventManagerTrap 54 }
ponLinkStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Link Status Notification."
::= { afsmgrEventManagerTrap 55 }
linkLoopbackTestNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Link Loopback Test Notification."
::= { afsmgrEventManagerTrap 57 }
ponOltOperStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Olt Oper Status Notification."
::= { afsmgrEventManagerTrap 68 }
ponOltAdminStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Olt Administrator Status Notification."
::= { afsmgrEventManagerTrap 69 }
ponOnuAdminStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Onu Admin Status Notification."
::= { afsmgrEventManagerTrap 70 }
ponOnuRegisterSubMacNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Onu Subscriber Mac Registration Notification."
::= { afsmgrEventManagerTrap 71 }
linkLoopbackTestFailNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Link Loopback Test Fail Notification."
::= { afsmgrEventManagerTrap 73 }
ponOnuRegOverloadNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Onu Register Overload Notification. (onu too many registration)"
::= { afsmgrEventManagerTrap 93 }
ponLinkRegNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Link Register Notification."
::= { afsmgrEventManagerTrap 96 }
ponOnuLoopDetectNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Onu Loop Detect Notification."
::= { afsmgrEventManagerTrap 97 }
ponOltImageUpgrageNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Olt Image Upgrade Notification."
::= { afsmgrEventManagerTrap 98 }
ponOltImageUpgrageFailNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Olt Image Upgrade Fail Notification."
::= { afsmgrEventManagerTrap 99 }
onuImageUpgradeNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"ONU Image Upgrade Notification."
::= { afsmgrEventManagerTrap 100 }
onuImageUpgradeFailNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"ONU Image Upgrade Fail Notification."
::= { afsmgrEventManagerTrap 101 }
onuLdShutdownNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"ONU LD shutdown Notification."
::= { afsmgrEventManagerTrap 102 }
ponUnadminMacRegNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Unadmin Mac-address Register Notification."
::= { afsmgrEventManagerTrap 103 }
ponDupMacRegNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Duplicated Mac-address Register Notification."
::= { afsmgrEventManagerTrap 104 }
ponOnuTypeMismatchNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Onu Type Mismatch Notification."
::= { afsmgrEventManagerTrap 105 }
ponOltDyingGaspNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Olt DyingGasp Notification."
::= { afsmgrEventManagerTrap 106 }
ponOltCableDownNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Olt Cable Down Notification."
::= { afsmgrEventManagerTrap 107 }
ponPMCcrc32MonitorNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"PMC CRC32 Monitor Notification."
::= { afsmgrEventManagerTrap 108 }
imageUpDownloadStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Image Up/Download Status Notification."
::= { afsmgrEventManagerTrap 109 }
imageUpDownloadFailNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Image Up/Download Fail Notification."
::= { afsmgrEventManagerTrap 110 }
configUpDownloadStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Config Up/Download Status Notification."
::= { afsmgrEventManagerTrap 111 }
sysRebootMaxTempNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"System Reboot by Max Temperature Notification."
::= { afsmgrEventManagerTrap 112 }
ponRogueOnuLdShutdown NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Rogue Onu Ld Shutdown Notification."
::= { afsmgrEventManagerTrap 113 }
scuOperStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"SCU Operation Status Notification."
::= { afsmgrEventManagerTrap 114 }
configUpDownloadFailNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Config Up/Download Fail Notification."
::= { afsmgrEventManagerTrap 115 }
ponOntRxPowerStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Ont Rx-optical-alarm Notification."
::= { afsmgrEventManagerTrap 116 }
ponOltRxPowerStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Olt Rx-optical-alarm Notification."
::= { afsmgrEventManagerTrap 117 }
ponOntTxPowerStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Ont Tx-optical-alarm Notification."
::= { afsmgrEventManagerTrap 118 }
ponOntTemperatureStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Ont Temperature-alarm Notification."
::= { afsmgrEventManagerTrap 119 }
ponOntVoltageStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Ont Voltage-alarm Notification."
::= { afsmgrEventManagerTrap 120 }
ponOntBiasStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Ont Bias-alarm Notification."
::= { afsmgrEventManagerTrap 121 }
ponOltRedSlaveFaultNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Olt Redundancy Slave Link Fault Notification."
::= { afsmgrEventManagerTrap 122 }
ponOltRedSwitchoverNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Olt Redundancy Switchover Notification."
::= { afsmgrEventManagerTrap 123 }
ponOnuOpticRxPowerOnusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Onus Low Optic Rx Power Notification."
::= { afsmgrEventManagerTrap 124 }
ponOnuDownThresholdNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Onu Down Threshold Notification."
::= { afsmgrEventManagerTrap 127 }
ponOnuFanStatusNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Onu Fan Status Notification."
::= { afsmgrEventManagerTrap 128 }
ExternalACAlarm NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"External AC alarm"
::= { afsmgrEventManagerTrap 129 }
ExternalUnitAlarm NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"External unit alarm."
::= { afsmgrEventManagerTrap 130 }
ponLoopCntThresholdNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Loop-Count-Threshold-alarm Notification."
::= { afsmgrEventManagerTrap 131 }
scuUnequipNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"scu unequip alarm"
::= { afsmgrEventManagerTrap 132 }
liuUnequipNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"liu unequip alarm"
::= { afsmgrEventManagerTrap 133 }
fmuUnequipNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"fmu unequip alarm"
::= { afsmgrEventManagerTrap 134 }
ponOltLineCodeErrorMonitorNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"OLT line code errors monitor Notification"
::= { afsmgrEventManagerTrap 135 }
ponOltAlignmentErrorMonitorNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"OLT alignment errors monitor Notification"
::= { afsmgrEventManagerTrap 136 }
scuEjectorAlarmNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"SCU ejector alarm Notification"
::= { afsmgrEventManagerTrap 137 }
systemCheckAlarm NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"EMS System Check Monitor Notification"
::= { afsmgrEventManagerTrap 138 }
ponOnuRegThreshOverNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Pon Onu Registration Threshold Over Notification"
::= { afsmgrEventManagerTrap 139 }
dcTempHighNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Dc Board Temperature High Threshold Notification"
::= { afsmgrEventManagerTrap 140 }
dcTempLowNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Dc Board Temperature Low Threshold Notification"
::= { afsmgrEventManagerTrap 141 }
humidityHighNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Mainboard Humidity High Threshold Notification"
::= { afsmgrEventManagerTrap 142 }
humidityLowNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Mainboard Humidity Low Threshold Notification"
::= { afsmgrEventManagerTrap 143 }
dcHumidityHighNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Dc Board Humidity High Threshold Notification"
::= { afsmgrEventManagerTrap 144 }
dcHumidityLowNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Dc Board Humidity Low Threshold Notification"
::= { afsmgrEventManagerTrap 145 }
sysRebootMaxDcTempNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"System Reboot by Max Dc Board Temperature Notification."
::= { afsmgrEventManagerTrap 146 }
sysRebootMaxHumidNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"System Reboot by Max Humidity Notification."
::= { afsmgrEventManagerTrap 147 }
sysRebootMaxDcHumidNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"System Reboot by Max Dc Board Humidity Notification."
::= { afsmgrEventManagerTrap 148 }
fanSpeedHighNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Fan Speed High Notification."
::= { afsmgrEventManagerTrap 149 }
psuUnequipNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Psu Unequip Notification."
::= { afsmgrEventManagerTrap 150 }
doorOpenAlarmNoti NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"Door Open Monitor Notification"
::= { afsmgrEventManagerTrap 151 }
ExternalMajorAlarm NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"External Power Major Alarm."
::= { afsmgrEventManagerTrap 152 }
Piu10gFanFailAlarm NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmId, alarmType, alarmSeverity, alarmPhysicalLoc, alarmLogicalLoc, alarmCurStatus, alarmAuxinfo, alarmDateTime, alarmStatus }
STATUS current
DESCRIPTION
"10G PIU Fan Fail Alarm."
::= { afsmgrEventManagerTrap 157 }
-- TODO
END
--
-- UBQS-AFSMGR-EVENT-MANAGEMENT-MIB.my
--