1562 lines
56 KiB
Plaintext
1562 lines
56 KiB
Plaintext
|
DISMAN-PING-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32,
|
||
|
Unsigned32, Gauge32, mib-2,
|
||
|
NOTIFICATION-TYPE, OBJECT-IDENTITY
|
||
|
FROM SNMPv2-SMI -- RFC2578
|
||
|
TEXTUAL-CONVENTION, RowStatus,
|
||
|
StorageType, DateAndTime, TruthValue
|
||
|
FROM SNMPv2-TC -- RFC2579
|
||
|
MODULE-COMPLIANCE, OBJECT-GROUP,
|
||
|
NOTIFICATION-GROUP
|
||
|
FROM SNMPv2-CONF -- RFC2580
|
||
|
InterfaceIndexOrZero -- RFC2863
|
||
|
FROM IF-MIB
|
||
|
SnmpAdminString
|
||
|
FROM SNMP-FRAMEWORK-MIB -- RFC3411
|
||
|
InetAddressType, InetAddress
|
||
|
FROM INET-ADDRESS-MIB; -- RFC4001
|
||
|
|
||
|
pingMIB MODULE-IDENTITY
|
||
|
LAST-UPDATED "200606130000Z" -- 13 June 2006
|
||
|
ORGANIZATION "IETF Distributed Management Working Group"
|
||
|
CONTACT-INFO
|
||
|
"Juergen Quittek
|
||
|
|
||
|
NEC Europe Ltd.
|
||
|
Network Laboratories
|
||
|
Kurfuersten-Anlage 36
|
||
|
69115 Heidelberg
|
||
|
Germany
|
||
|
|
||
|
Phone: +49 6221 4342-115
|
||
|
|
||
|
Email: quittek@netlab.nec.de"
|
||
|
DESCRIPTION
|
||
|
"The Ping MIB (DISMAN-PING-MIB) provides the capability of
|
||
|
controlling the use of the ping function at a remote
|
||
|
host.
|
||
|
|
||
|
Copyright (C) The Internet Society (2006). This version of
|
||
|
this MIB module is part of RFC 4560; see the RFC itself for
|
||
|
full legal notices."
|
||
|
|
||
|
-- Revision history
|
||
|
|
||
|
REVISION "200606130000Z" -- 13 June 2006
|
||
|
DESCRIPTION
|
||
|
"Updated version, published as RFC 4560.
|
||
|
- Correctly considered IPv6 in DESCRIPTION
|
||
|
clause of pingCtlDataSize
|
||
|
- Replaced references to RFC 2575 by RFC 3415
|
||
|
- Replaced references to RFC 2571 by RFC 3411
|
||
|
- Replaced references to RFC 2851 by RFC 4001
|
||
|
- Added DEFVAL { {} } to definition of
|
||
|
pingCtlTrapGeneration
|
||
|
- Changed DEFVAL of object pingCtlDescr from
|
||
|
DEFVAL { '00'H } to DEFVAL { ''H }
|
||
|
- Changed DEFVAL of object pingCtlSourceAddressType
|
||
|
from DEFVAL { ipv4 } to DEFVAL { unknown }
|
||
|
- Extended DESCRIPTION clause of pingResultsTable
|
||
|
describing re-initialization of entries
|
||
|
- Changed SYNTAX of pingResultsProbeResponses and
|
||
|
pingResultsSentProbes from Unsigned32 to Gauge32
|
||
|
- Changed status of pingCompliance to deprecated
|
||
|
- Added pingFullCompliance and pingMinimumCompliance
|
||
|
- Changed status of pingGroup and pingTimeStampGroup
|
||
|
to deprecated
|
||
|
- Added pingMinimumGroup, pingCtlRowStatusGroup,
|
||
|
and pingHistoryGroup"
|
||
|
|
||
|
REVISION "200009210000Z" -- 21 September 2000
|
||
|
DESCRIPTION
|
||
|
"Initial version, published as RFC 2925."
|
||
|
::= { mib-2 80 }
|
||
|
|
||
|
-- Textual Conventions
|
||
|
|
||
|
OperationResponseStatus ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used to report the result of an operation:
|
||
|
|
||
|
responseReceived(1) - Operation is completed successfully.
|
||
|
unknown(2) - Operation failed due to unknown error.
|
||
|
internalError(3) - An implementation detected an error
|
||
|
in its own processing that caused an operation
|
||
|
to fail.
|
||
|
requestTimedOut(4) - Operation failed to receive a
|
||
|
valid reply within the time limit imposed on it.
|
||
|
unknownDestinationAddress(5) - Invalid destination
|
||
|
address.
|
||
|
noRouteToTarget(6) - Could not find a route to target.
|
||
|
interfaceInactiveToTarget(7) - The interface to be
|
||
|
used in sending a probe is inactive, and an
|
||
|
alternate route does not exist.
|
||
|
arpFailure(8) - Unable to resolve a target address to a
|
||
|
media-specific address.
|
||
|
maxConcurrentLimitReached(9) - The maximum number of
|
||
|
concurrent active operations would have been exceeded
|
||
|
if the corresponding operation was allowed.
|
||
|
unableToResolveDnsName(10) - The DNS name specified was
|
||
|
unable to be mapped to an IP address.
|
||
|
invalidHostAddress(11) - The IP address for a host
|
||
|
has been determined to be invalid. Examples of this
|
||
|
are broadcast or multicast addresses."
|
||
|
SYNTAX INTEGER {
|
||
|
responseReceived(1),
|
||
|
unknown(2),
|
||
|
internalError(3),
|
||
|
requestTimedOut(4),
|
||
|
unknownDestinationAddress(5),
|
||
|
noRouteToTarget(6),
|
||
|
interfaceInactiveToTarget(7),
|
||
|
arpFailure(8),
|
||
|
maxConcurrentLimitReached(9),
|
||
|
unableToResolveDnsName(10),
|
||
|
invalidHostAddress(11)
|
||
|
}
|
||
|
|
||
|
-- Top level structure of the MIB
|
||
|
|
||
|
pingNotifications OBJECT IDENTIFIER ::= { pingMIB 0 }
|
||
|
pingObjects OBJECT IDENTIFIER ::= { pingMIB 1 }
|
||
|
pingConformance OBJECT IDENTIFIER ::= { pingMIB 2 }
|
||
|
|
||
|
-- The registration node (point) for ping implementation types
|
||
|
|
||
|
pingImplementationTypeDomains OBJECT IDENTIFIER ::= { pingMIB 3 }
|
||
|
|
||
|
pingIcmpEcho OBJECT-IDENTITY
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates that an implementation is using the Internet
|
||
|
Control Message Protocol (ICMP) 'ECHO' facility."
|
||
|
::= { pingImplementationTypeDomains 1 }
|
||
|
|
||
|
pingUdpEcho OBJECT-IDENTITY
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates that an implementation is using the UDP echo
|
||
|
port (7)."
|
||
|
REFERENCE
|
||
|
"RFC 862, 'Echo Protocol'."
|
||
|
::= { pingImplementationTypeDomains 2 }
|
||
|
|
||
|
pingSnmpQuery OBJECT-IDENTITY
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates that an implementation is using an SNMP query
|
||
|
to calculate a round trip time."
|
||
|
::= { pingImplementationTypeDomains 3 }
|
||
|
|
||
|
pingTcpConnectionAttempt OBJECT-IDENTITY
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates that an implementation is attempting to
|
||
|
connect to a TCP port in order to calculate a round
|
||
|
trip time."
|
||
|
::= { pingImplementationTypeDomains 4 }
|
||
|
|
||
|
-- Simple Object Definitions
|
||
|
|
||
|
pingMaxConcurrentRequests OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "requests"
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum number of concurrent active ping requests
|
||
|
that are allowed within an agent implementation. A value
|
||
|
of 0 for this object implies that there is no limit for
|
||
|
the number of concurrent active requests in effect.
|
||
|
|
||
|
The limit applies only to new requests being activated.
|
||
|
When a new value is set, the agent will continue processing
|
||
|
all the requests already active, even if their number
|
||
|
exceeds the limit just imposed."
|
||
|
DEFVAL { 10 }
|
||
|
::= { pingObjects 1 }
|
||
|
|
||
|
-- Ping Control Table
|
||
|
|
||
|
pingCtlTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PingCtlEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Defines the ping Control Table for providing, via SNMP,
|
||
|
the capability of performing ping operations at
|
||
|
a remote host. The results of these operations are
|
||
|
stored in the pingResultsTable and the
|
||
|
pingProbeHistoryTable."
|
||
|
::= { pingObjects 2 }
|
||
|
|
||
|
pingCtlEntry OBJECT-TYPE
|
||
|
SYNTAX PingCtlEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Defines an entry in the pingCtlTable. The first index
|
||
|
element, pingCtlOwnerIndex, is of type SnmpAdminString,
|
||
|
a textual convention that allows for use of the SNMPv3
|
||
|
View-Based Access Control Model (RFC 3415, VACM)
|
||
|
and that allows a management application to identify its
|
||
|
entries. The second index, pingCtlTestName (also an
|
||
|
SnmpAdminString), enables the same management
|
||
|
application to have multiple outstanding requests."
|
||
|
INDEX {
|
||
|
pingCtlOwnerIndex,
|
||
|
pingCtlTestName
|
||
|
}
|
||
|
::= { pingCtlTable 1 }
|
||
|
|
||
|
PingCtlEntry ::=
|
||
|
SEQUENCE {
|
||
|
pingCtlOwnerIndex SnmpAdminString,
|
||
|
pingCtlTestName SnmpAdminString,
|
||
|
pingCtlTargetAddressType InetAddressType,
|
||
|
pingCtlTargetAddress InetAddress,
|
||
|
pingCtlDataSize Unsigned32,
|
||
|
pingCtlTimeOut Unsigned32,
|
||
|
pingCtlProbeCount Unsigned32,
|
||
|
pingCtlAdminStatus INTEGER,
|
||
|
pingCtlDataFill OCTET STRING,
|
||
|
pingCtlFrequency Unsigned32,
|
||
|
pingCtlMaxRows Unsigned32,
|
||
|
pingCtlStorageType StorageType,
|
||
|
pingCtlTrapGeneration BITS,
|
||
|
pingCtlTrapProbeFailureFilter Unsigned32,
|
||
|
pingCtlTrapTestFailureFilter Unsigned32,
|
||
|
pingCtlType OBJECT IDENTIFIER,
|
||
|
pingCtlDescr SnmpAdminString,
|
||
|
pingCtlSourceAddressType InetAddressType,
|
||
|
pingCtlSourceAddress InetAddress,
|
||
|
pingCtlIfIndex InterfaceIndexOrZero,
|
||
|
pingCtlByPassRouteTable TruthValue,
|
||
|
pingCtlDSField Unsigned32,
|
||
|
pingCtlRowStatus RowStatus
|
||
|
}
|
||
|
|
||
|
pingCtlOwnerIndex OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(0..32))
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"To facilitate the provisioning of access control by a
|
||
|
security administrator using the View-Based Access
|
||
|
Control Model (RFC 2575, VACM) for tables in which
|
||
|
multiple users may need to create or
|
||
|
modify entries independently, the initial index is used
|
||
|
as an 'owner index'. Such an initial index has a syntax
|
||
|
of SnmpAdminString and can thus be trivially mapped to a
|
||
|
securityName or groupName defined in VACM, in
|
||
|
accordance with a security policy.
|
||
|
|
||
|
When used in conjunction with such a security policy, all
|
||
|
entries in the table belonging to a particular user (or
|
||
|
group) will have the same value for this initial index.
|
||
|
For a given user's entries in a particular table, the
|
||
|
object identifiers for the information in these entries
|
||
|
will have the same subidentifiers (except for the 'column'
|
||
|
subidentifier) up to the end of the encoded owner index.
|
||
|
To configure VACM to permit access to this portion of the
|
||
|
table, one would create vacmViewTreeFamilyTable entries
|
||
|
with the value of vacmViewTreeFamilySubtree including
|
||
|
the owner index portion, and vacmViewTreeFamilyMask
|
||
|
'wildcarding' the column subidentifier. More elaborate
|
||
|
configurations are possible."
|
||
|
::= { pingCtlEntry 1 }
|
||
|
|
||
|
pingCtlTestName OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString (SIZE(0..32))
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The name of the ping test. This is locally unique, within
|
||
|
the scope of a pingCtlOwnerIndex."
|
||
|
::= { pingCtlEntry 2 }
|
||
|
|
||
|
pingCtlTargetAddressType OBJECT-TYPE
|
||
|
SYNTAX InetAddressType
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Specifies the type of host address to be used at a remote
|
||
|
host for performing a ping operation."
|
||
|
DEFVAL { unknown }
|
||
|
::= { pingCtlEntry 3 }
|
||
|
|
||
|
pingCtlTargetAddress OBJECT-TYPE
|
||
|
SYNTAX InetAddress
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Specifies the host address to be used at a remote host for
|
||
|
performing a ping operation. The host address type is
|
||
|
determined by the value of the corresponding
|
||
|
pingCtlTargetAddressType.
|
||
|
|
||
|
A value for this object MUST be set prior to transitioning
|
||
|
its corresponding pingCtlEntry to active(1) via
|
||
|
pingCtlRowStatus."
|
||
|
DEFVAL { ''H }
|
||
|
::= { pingCtlEntry 4 }
|
||
|
|
||
|
pingCtlDataSize OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..65507)
|
||
|
UNITS "octets"
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Specifies the size of the data portion to be
|
||
|
transmitted in a ping operation, in octets. Whether this
|
||
|
value can be applied depends on the selected
|
||
|
implementation method for performing a ping operation,
|
||
|
indicated by pingCtlType in the same conceptual row.
|
||
|
If the method used allows applying the value contained
|
||
|
|
||
|
in this object, then it MUST be applied. If the specified
|
||
|
size is not appropriate for the chosen ping method, the
|
||
|
implementation SHOULD use whatever size (appropriate to
|
||
|
the method) is closest to the specified size.
|
||
|
|
||
|
The maximum value for this object was computed by
|
||
|
subtracting the smallest possible IP header size of
|
||
|
20 octets (IPv4 header with no options) and the UDP
|
||
|
header size of 8 octets from the maximum IP packet size.
|
||
|
An IP packet has a maximum size of 65535 octets
|
||
|
(excluding IPv6 Jumbograms)."
|
||
|
DEFVAL { 0 }
|
||
|
::= { pingCtlEntry 5 }
|
||
|
|
||
|
pingCtlTimeOut OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..60)
|
||
|
UNITS "seconds"
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Specifies the time-out value, in seconds, for a
|
||
|
remote ping operation."
|
||
|
DEFVAL { 3 }
|
||
|
::= { pingCtlEntry 6 }
|
||
|
|
||
|
pingCtlProbeCount OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..15)
|
||
|
UNITS "probes"
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Specifies the number of times to perform a ping
|
||
|
operation at a remote host as part of a single ping test."
|
||
|
DEFVAL { 1 }
|
||
|
::= { pingCtlEntry 7 }
|
||
|
|
||
|
pingCtlAdminStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
enabled(1), -- test should be started
|
||
|
disabled(2) -- test should be stopped
|
||
|
}
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Reflects the desired state that a pingCtlEntry should be
|
||
|
in:
|
||
|
|
||
|
enabled(1) - Attempt to activate the test as defined by
|
||
|
this pingCtlEntry.
|
||
|
disabled(2) - Deactivate the test as defined by this
|
||
|
pingCtlEntry.
|
||
|
|
||
|
Refer to the corresponding pingResultsOperStatus to
|
||
|
determine the operational state of the test defined by
|
||
|
this entry."
|
||
|
DEFVAL { disabled }
|
||
|
::= { pingCtlEntry 8 }
|
||
|
|
||
|
pingCtlDataFill OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..1024))
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The content of this object is used together with the
|
||
|
corresponding pingCtlDataSize value to determine how to
|
||
|
fill the data portion of a probe packet. The option of
|
||
|
selecting a data fill pattern can be useful when links
|
||
|
are compressed or have data pattern sensitivities. The
|
||
|
contents of pingCtlDataFill should be repeated in a ping
|
||
|
packet when the size of the data portion of the ping
|
||
|
packet is greater than the size of pingCtlDataFill."
|
||
|
DEFVAL { '00'H }
|
||
|
::= { pingCtlEntry 9 }
|
||
|
|
||
|
pingCtlFrequency OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "seconds"
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of seconds to wait before repeating a ping test
|
||
|
as defined by the value of the various objects in the
|
||
|
corresponding row.
|
||
|
|
||
|
A single ping test consists of a series of ping probes.
|
||
|
The number of probes is determined by the value of the
|
||
|
corresponding pingCtlProbeCount object. After a single
|
||
|
test is completed the number of seconds as defined by the
|
||
|
value of pingCtlFrequency MUST elapse before the
|
||
|
next ping test is started.
|
||
|
|
||
|
A value of 0 for this object implies that the test
|
||
|
as defined by the corresponding entry will not be
|
||
|
repeated."
|
||
|
DEFVAL { 0 }
|
||
|
::= { pingCtlEntry 10 }
|
||
|
|
||
|
pingCtlMaxRows OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "rows"
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum number of corresponding entries allowed
|
||
|
in the pingProbeHistoryTable. An implementation of this
|
||
|
MIB will remove the oldest corresponding entry in the
|
||
|
pingProbeHistoryTable to allow the addition of an
|
||
|
new entry once the number of corresponding rows in the
|
||
|
pingProbeHistoryTable reaches this value.
|
||
|
|
||
|
Old entries are not removed when a new test is
|
||
|
started. Entries are added to the pingProbeHistoryTable
|
||
|
until pingCtlMaxRows is reached before entries begin to
|
||
|
be removed.
|
||
|
|
||
|
A value of 0 for this object disables creation of
|
||
|
pingProbeHistoryTable entries."
|
||
|
DEFVAL { 50 }
|
||
|
::= { pingCtlEntry 11 }
|
||
|
|
||
|
pingCtlStorageType OBJECT-TYPE
|
||
|
SYNTAX StorageType
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The storage type for this conceptual row.
|
||
|
Conceptual rows having the value 'permanent' need not
|
||
|
allow write-access to any columnar objects in the row."
|
||
|
DEFVAL { nonVolatile }
|
||
|
::= { pingCtlEntry 12 }
|
||
|
|
||
|
pingCtlTrapGeneration OBJECT-TYPE
|
||
|
SYNTAX BITS {
|
||
|
probeFailure(0),
|
||
|
testFailure(1),
|
||
|
testCompletion(2)
|
||
|
}
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of this object determines when and whether
|
||
|
to generate a notification for this entry:
|
||
|
|
||
|
probeFailure(0) - Generate a pingProbeFailed
|
||
|
notification subject to the value of
|
||
|
pingCtlTrapProbeFailureFilter. The object
|
||
|
pingCtlTrapProbeFailureFilter can be used
|
||
|
to specify the number of consecutive probe
|
||
|
failures that are required before a
|
||
|
pingProbeFailed notification can be generated.
|
||
|
testFailure(1) - Generate a pingTestFailed
|
||
|
notification. In this instance the object
|
||
|
pingCtlTrapTestFailureFilter can be used to
|
||
|
determine the number of probe failures that
|
||
|
signal when a test fails.
|
||
|
testCompletion(2) - Generate a pingTestCompleted
|
||
|
notification.
|
||
|
|
||
|
By default, no bits are set, indicating that
|
||
|
none of the above options is selected."
|
||
|
DEFVAL { {} } -- no bits set.
|
||
|
::= { pingCtlEntry 13 }
|
||
|
|
||
|
pingCtlTrapProbeFailureFilter OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..15)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of this object is used to determine when
|
||
|
to generate a pingProbeFailed NOTIFICATION.
|
||
|
|
||
|
Setting BIT probeFailure(0) of object
|
||
|
pingCtlTrapGeneration to '1' implies that a
|
||
|
pingProbeFailed NOTIFICATION is generated only when
|
||
|
|
||
|
a number of consecutive ping probes equal to the
|
||
|
value of pingCtlTrapProbeFailureFilter fail within
|
||
|
a given ping test. After triggering the notification,
|
||
|
the probe failure counter is reset to zero."
|
||
|
DEFVAL { 1 }
|
||
|
::= { pingCtlEntry 14 }
|
||
|
|
||
|
pingCtlTrapTestFailureFilter OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..15)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of this object is used to determine when
|
||
|
to generate a pingTestFailed NOTIFICATION.
|
||
|
|
||
|
Setting BIT testFailure(1) of object
|
||
|
|
||
|
pingCtlTrapGeneration to '1' implies that a
|
||
|
pingTestFailed NOTIFICATION is generated only when
|
||
|
a number of consecutive ping tests equal to the
|
||
|
value of pingCtlTrapProbeFailureFilter fail.
|
||
|
After triggering the notification, the test failure
|
||
|
counter is reset to zero."
|
||
|
DEFVAL { 1 }
|
||
|
::= { pingCtlEntry 15 }
|
||
|
|
||
|
pingCtlType OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of this object is used either to report or
|
||
|
to select the implementation method to be used for
|
||
|
calculating a ping response time. The value of this
|
||
|
object MAY be selected from pingImplementationTypeDomains.
|
||
|
|
||
|
Additional implementation types SHOULD be allocated as
|
||
|
required by implementers of the DISMAN-PING-MIB under
|
||
|
their enterprise-specific registration point and not
|
||
|
beneath pingImplementationTypeDomains."
|
||
|
DEFVAL { pingIcmpEcho }
|
||
|
::= { pingCtlEntry 16 }
|
||
|
|
||
|
pingCtlDescr OBJECT-TYPE
|
||
|
SYNTAX SnmpAdminString
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The purpose of this object is to provide a
|
||
|
descriptive name of the remote ping test."
|
||
|
DEFVAL { ''H }
|
||
|
::= { pingCtlEntry 17 }
|
||
|
|
||
|
pingCtlSourceAddressType OBJECT-TYPE
|
||
|
SYNTAX InetAddressType
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Specifies the type of the source address,
|
||
|
pingCtlSourceAddress, to be used at a remote host
|
||
|
when a ping operation is performed."
|
||
|
DEFVAL { unknown }
|
||
|
::= { pingCtlEntry 18 }
|
||
|
|
||
|
pingCtlSourceAddress OBJECT-TYPE
|
||
|
SYNTAX InetAddress
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Use the specified IP address (which must be given in
|
||
|
numeric form, not as a hostname) as the source address
|
||
|
in outgoing probe packets. On hosts with more than one
|
||
|
IP address, this option can be used to select the address
|
||
|
to be used. If the IP address is not one of this
|
||
|
machine's interface addresses, an error is returned and
|
||
|
nothing is sent. A zero-length octet string value for
|
||
|
this object disables source address specification.
|
||
|
|
||
|
The address type (InetAddressType) that relates to
|
||
|
this object is specified by the corresponding value
|
||
|
of pingCtlSourceAddressType."
|
||
|
DEFVAL { ''H }
|
||
|
::= { pingCtlEntry 19 }
|
||
|
|
||
|
pingCtlIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndexOrZero
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Setting this object to an interface's ifIndex prior
|
||
|
to starting a remote ping operation directs
|
||
|
the ping probes to be transmitted over the
|
||
|
specified interface. A value of zero for this object
|
||
|
means that this option is not enabled."
|
||
|
DEFVAL { 0 }
|
||
|
::= { pingCtlEntry 20 }
|
||
|
|
||
|
pingCtlByPassRouteTable OBJECT-TYPE
|
||
|
SYNTAX TruthValue
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The purpose of this object is to enable optional
|
||
|
bypassing the route table. If enabled, the remote
|
||
|
host will bypass the normal routing tables and send
|
||
|
directly to a host on an attached network. If the
|
||
|
host is not on a directly attached network, an
|
||
|
error is returned. This option can be used to perform
|
||
|
the ping operation to a local host through an
|
||
|
interface that has no route defined (e.g., after the
|
||
|
interface was dropped by the routing daemon at the host)."
|
||
|
DEFVAL { false }
|
||
|
::= { pingCtlEntry 21 }
|
||
|
|
||
|
pingCtlDSField OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (0..255)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Specifies the value to store in the Type of Service
|
||
|
(TOS) octet in the IPv4 header or in the Traffic
|
||
|
Class octet in the IPv6 header, respectively, of the
|
||
|
IP packet used to encapsulate the ping probe.
|
||
|
|
||
|
The octet to be set in the IP header contains the
|
||
|
Differentiated Services (DS) Field in the six most
|
||
|
significant bits.
|
||
|
|
||
|
This option can be used to determine what effect an
|
||
|
explicit DS Field setting has on a ping response.
|
||
|
Not all values are legal or meaningful. A value of 0
|
||
|
means that the function represented by this option is
|
||
|
not supported. DS Field usage is often not supported
|
||
|
by IP implementations, and not all values are supported.
|
||
|
Refer to RFC 2474 and RFC 3260 for guidance on usage of
|
||
|
this field."
|
||
|
REFERENCE
|
||
|
"Refer to RFC 1812 for the definition of the IPv4 TOS
|
||
|
octet and to RFC 2460 for the definition of the IPv6
|
||
|
Traffic Class octet. Refer to RFC 2474 and RFC 3260
|
||
|
for the definition of the Differentiated Services Field."
|
||
|
DEFVAL { 0 }
|
||
|
::= { pingCtlEntry 22 }
|
||
|
|
||
|
pingCtlRowStatus OBJECT-TYPE
|
||
|
SYNTAX RowStatus
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object allows entries to be created and deleted
|
||
|
in the pingCtlTable. Deletion of an entry in this
|
||
|
table results in the deletion of all corresponding (same
|
||
|
pingCtlOwnerIndex and pingCtlTestName index values)
|
||
|
pingResultsTable and pingProbeHistoryTable entries.
|
||
|
|
||
|
A value MUST be specified for pingCtlTargetAddress
|
||
|
prior to acceptance of a transition to active(1) state.
|
||
|
|
||
|
When a value for pingCtlTargetAddress is set,
|
||
|
the value of object pingCtlRowStatus changes
|
||
|
from notReady(3) to notInService(2).
|
||
|
|
||
|
Activation of a remote ping operation is controlled
|
||
|
via pingCtlAdminStatus, not by changing
|
||
|
this object's value to active(1).
|
||
|
|
||
|
Transitions in and out of active(1) state are not
|
||
|
allowed while an entry's pingResultsOperStatus is
|
||
|
active(1), with the exception that deletion of
|
||
|
an entry in this table by setting its RowStatus
|
||
|
object to destroy(6) will stop an active
|
||
|
ping operation.
|
||
|
|
||
|
The operational state of a ping operation
|
||
|
can be determined by examination of its
|
||
|
pingResultsOperStatus object."
|
||
|
REFERENCE
|
||
|
"See definition of RowStatus in RFC 2579, 'Textual
|
||
|
Conventions for SMIv2.'"
|
||
|
::= { pingCtlEntry 23 }
|
||
|
|
||
|
-- Ping Results Table
|
||
|
|
||
|
pingResultsTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PingResultsEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Defines the Ping Results Table for providing
|
||
|
the capability of performing ping operations at
|
||
|
a remote host. The results of these operations are
|
||
|
stored in the pingResultsTable and the pingProbeHistoryTable.
|
||
|
|
||
|
An entry is added to the pingResultsTable when an
|
||
|
pingCtlEntry is started by successful transition
|
||
|
of its pingCtlAdminStatus object to enabled(1).
|
||
|
|
||
|
If the object pingCtlAdminStatus already has the value
|
||
|
enabled(1), and if the corresponding pingResultsOperStatus
|
||
|
object has the value completed(3), then successfully writing
|
||
|
enabled(1) to object pingCtlAdminStatus re-initializes the
|
||
|
already existing entry in the pingResultsTable. The values
|
||
|
of objects in the re-initialized entry are the same as the
|
||
|
values of objects in a new entry would be.
|
||
|
|
||
|
An entry is removed from the pingResultsTable when
|
||
|
its corresponding pingCtlEntry is deleted."
|
||
|
::= { pingObjects 3 }
|
||
|
|
||
|
pingResultsEntry OBJECT-TYPE
|
||
|
SYNTAX PingResultsEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Defines an entry in the pingResultsTable. The
|
||
|
pingResultsTable has the same indexing as the
|
||
|
pingCtlTable so that a pingResultsEntry
|
||
|
corresponds to the pingCtlEntry that caused it to
|
||
|
be created."
|
||
|
INDEX {
|
||
|
pingCtlOwnerIndex,
|
||
|
pingCtlTestName
|
||
|
}
|
||
|
::= { pingResultsTable 1 }
|
||
|
|
||
|
PingResultsEntry ::=
|
||
|
SEQUENCE {
|
||
|
pingResultsOperStatus INTEGER,
|
||
|
pingResultsIpTargetAddressType InetAddressType,
|
||
|
pingResultsIpTargetAddress InetAddress,
|
||
|
pingResultsMinRtt Unsigned32,
|
||
|
pingResultsMaxRtt Unsigned32,
|
||
|
pingResultsAverageRtt Unsigned32,
|
||
|
pingResultsProbeResponses Gauge32,
|
||
|
pingResultsSentProbes Gauge32,
|
||
|
pingResultsRttSumOfSquares Unsigned32,
|
||
|
pingResultsLastGoodProbe DateAndTime
|
||
|
}
|
||
|
|
||
|
pingResultsOperStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
enabled(1), -- test is in progress
|
||
|
disabled(2), -- test has stopped
|
||
|
completed(3) -- test is completed
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Reflects the operational state of a pingCtlEntry:
|
||
|
|
||
|
enabled(1) - Test is active.
|
||
|
disabled(2) - Test has stopped.
|
||
|
completed(3) - Test is completed."
|
||
|
::= { pingResultsEntry 1 }
|
||
|
|
||
|
pingResultsIpTargetAddressType OBJECT-TYPE
|
||
|
SYNTAX InetAddressType
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the type of address stored
|
||
|
in the corresponding pingResultsIpTargetAddress
|
||
|
object."
|
||
|
DEFVAL { unknown }
|
||
|
::= { pingResultsEntry 2 }
|
||
|
|
||
|
pingResultsIpTargetAddress OBJECT-TYPE
|
||
|
SYNTAX InetAddress
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object reports the IP address associated
|
||
|
with a pingCtlTargetAddress value when the destination
|
||
|
address is specified as a DNS name. The value of
|
||
|
this object should be a zero-length octet string
|
||
|
when a DNS name is not specified or when a
|
||
|
specified DNS name fails to resolve.
|
||
|
|
||
|
The address type (InetAddressType) that relates to
|
||
|
this object is specified by the corresponding value
|
||
|
of pingResultsIpTargetAddressType."
|
||
|
DEFVAL { ''H }
|
||
|
::= { pingResultsEntry 3 }
|
||
|
|
||
|
pingResultsMinRtt OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "milliseconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The minimum ping round-trip-time (RTT) received. A value
|
||
|
of 0 for this object implies that no RTT has been received."
|
||
|
::= { pingResultsEntry 4 }
|
||
|
|
||
|
pingResultsMaxRtt OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "milliseconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum ping round-trip-time (RTT) received. A value
|
||
|
of 0 for this object implies that no RTT has been received."
|
||
|
::= { pingResultsEntry 5 }
|
||
|
|
||
|
pingResultsAverageRtt OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "milliseconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current average ping round-trip-time (RTT)."
|
||
|
::= { pingResultsEntry 6 }
|
||
|
|
||
|
pingResultsProbeResponses OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
UNITS "responses"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of responses received for the corresponding
|
||
|
pingCtlEntry and pingResultsEntry. The value of this object
|
||
|
MUST be reported as 0 when no probe responses have been
|
||
|
received."
|
||
|
::= { pingResultsEntry 7 }
|
||
|
|
||
|
pingResultsSentProbes OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
UNITS "probes"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of this object reflects the number of probes sent
|
||
|
for the corresponding pingCtlEntry and pingResultsEntry.
|
||
|
The value of this object MUST be reported as 0 when no probes
|
||
|
have been sent."
|
||
|
::= { pingResultsEntry 8 }
|
||
|
|
||
|
pingResultsRttSumOfSquares OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "milliseconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object contains the sum of the squares for all ping
|
||
|
responses received. Its purpose is to enable standard
|
||
|
deviation calculation. The value of this object MUST
|
||
|
be reported as 0 when no ping responses have been
|
||
|
received."
|
||
|
::= { pingResultsEntry 9 }
|
||
|
|
||
|
pingResultsLastGoodProbe OBJECT-TYPE
|
||
|
SYNTAX DateAndTime
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Date and time when the last response was received for
|
||
|
a probe."
|
||
|
::= { pingResultsEntry 10 }
|
||
|
|
||
|
-- Ping Probe History Table
|
||
|
|
||
|
pingProbeHistoryTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PingProbeHistoryEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Defines a table for storing the results of ping
|
||
|
operations. The number of entries in this table is
|
||
|
limited per entry in the pingCtlTable by the value
|
||
|
of the corresponding pingCtlMaxRows object.
|
||
|
|
||
|
An entry in this table is created when the result of
|
||
|
a ping probe is determined. The initial 2 instance
|
||
|
identifier index values identify the pingCtlEntry
|
||
|
that a probe result (pingProbeHistoryEntry) belongs
|
||
|
to. An entry is removed from this table when
|
||
|
its corresponding pingCtlEntry is deleted.
|
||
|
|
||
|
An implementation of this MIB will remove the oldest
|
||
|
entry in the pingProbeHistoryTable of the
|
||
|
corresponding entry in the pingCtlTable to allow
|
||
|
the addition of an new entry once the number of rows
|
||
|
in the pingProbeHistoryTable reaches the value
|
||
|
specified by pingCtlMaxRows for the corresponding
|
||
|
entry in the pingCtlTable."
|
||
|
::= { pingObjects 4 }
|
||
|
|
||
|
pingProbeHistoryEntry OBJECT-TYPE
|
||
|
SYNTAX PingProbeHistoryEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Defines an entry in the pingProbeHistoryTable.
|
||
|
The first two index elements identify the
|
||
|
pingCtlEntry that a pingProbeHistoryEntry belongs
|
||
|
to. The third index element selects a single
|
||
|
probe result."
|
||
|
INDEX {
|
||
|
|
||
|
pingCtlOwnerIndex,
|
||
|
pingCtlTestName,
|
||
|
pingProbeHistoryIndex
|
||
|
}
|
||
|
::= { pingProbeHistoryTable 1 }
|
||
|
|
||
|
PingProbeHistoryEntry ::=
|
||
|
SEQUENCE {
|
||
|
pingProbeHistoryIndex Unsigned32,
|
||
|
pingProbeHistoryResponse Unsigned32,
|
||
|
pingProbeHistoryStatus OperationResponseStatus,
|
||
|
pingProbeHistoryLastRC Integer32,
|
||
|
pingProbeHistoryTime DateAndTime
|
||
|
}
|
||
|
|
||
|
pingProbeHistoryIndex OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..'ffffffff'h)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in this table is created when the result of
|
||
|
a ping probe is determined. The initial 2 instance
|
||
|
identifier index values identify the pingCtlEntry
|
||
|
that a probe result (pingProbeHistoryEntry) belongs
|
||
|
to.
|
||
|
|
||
|
An implementation MUST start assigning
|
||
|
pingProbeHistoryIndex values at 1 and wrap after
|
||
|
exceeding the maximum possible value as defined by
|
||
|
the limit of this object ('ffffffff'h)."
|
||
|
::= { pingProbeHistoryEntry 1 }
|
||
|
|
||
|
pingProbeHistoryResponse OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
UNITS "milliseconds"
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The amount of time measured in milliseconds from when
|
||
|
a probe was sent to when its response was received or
|
||
|
when it timed out. The value of this object is reported
|
||
|
as 0 when it is not possible to transmit a probe."
|
||
|
::= { pingProbeHistoryEntry 2 }
|
||
|
|
||
|
pingProbeHistoryStatus OBJECT-TYPE
|
||
|
SYNTAX OperationResponseStatus
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The result of a particular probe done by a remote host."
|
||
|
::= { pingProbeHistoryEntry 3 }
|
||
|
|
||
|
pingProbeHistoryLastRC OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The last implementation-method-specific reply code received.
|
||
|
If the ICMP Echo capability is being used, then a successful
|
||
|
probe ends when an ICMP response is received that contains
|
||
|
the code ICMP_ECHOREPLY(0). The ICMP codes are maintained
|
||
|
by IANA. Standardized ICMP codes are listed at
|
||
|
http://www.iana.org/assignments/icmp-parameters.
|
||
|
The ICMPv6 codes are listed at
|
||
|
http://www.iana.org/assignments/icmpv6-parameters."
|
||
|
::= { pingProbeHistoryEntry 4 }
|
||
|
|
||
|
pingProbeHistoryTime OBJECT-TYPE
|
||
|
SYNTAX DateAndTime
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Timestamp for when this probe result was determined."
|
||
|
::= { pingProbeHistoryEntry 5 }
|
||
|
|
||
|
-- Notification Definition section
|
||
|
|
||
|
pingProbeFailed NOTIFICATION-TYPE
|
||
|
OBJECTS {
|
||
|
pingCtlTargetAddressType,
|
||
|
pingCtlTargetAddress,
|
||
|
pingResultsOperStatus,
|
||
|
pingResultsIpTargetAddressType,
|
||
|
pingResultsIpTargetAddress,
|
||
|
pingResultsMinRtt,
|
||
|
pingResultsMaxRtt,
|
||
|
pingResultsAverageRtt,
|
||
|
pingResultsProbeResponses,
|
||
|
pingResultsSentProbes,
|
||
|
pingResultsRttSumOfSquares,
|
||
|
pingResultsLastGoodProbe
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Generated when a probe failure is detected, when the
|
||
|
|
||
|
corresponding pingCtlTrapGeneration object is set to
|
||
|
probeFailure(0), subject to the value of
|
||
|
pingCtlTrapProbeFailureFilter. The object
|
||
|
pingCtlTrapProbeFailureFilter can be used to specify the
|
||
|
number of consecutive probe failures that are required
|
||
|
before this notification can be generated."
|
||
|
::= { pingNotifications 1 }
|
||
|
|
||
|
pingTestFailed NOTIFICATION-TYPE
|
||
|
OBJECTS {
|
||
|
pingCtlTargetAddressType,
|
||
|
pingCtlTargetAddress,
|
||
|
pingResultsOperStatus,
|
||
|
pingResultsIpTargetAddressType,
|
||
|
pingResultsIpTargetAddress,
|
||
|
pingResultsMinRtt,
|
||
|
pingResultsMaxRtt,
|
||
|
pingResultsAverageRtt,
|
||
|
pingResultsProbeResponses,
|
||
|
pingResultsSentProbes,
|
||
|
pingResultsRttSumOfSquares,
|
||
|
pingResultsLastGoodProbe
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Generated when a ping test is determined to have failed,
|
||
|
when the corresponding pingCtlTrapGeneration object is
|
||
|
set to testFailure(1). In this instance,
|
||
|
pingCtlTrapTestFailureFilter should specify the number of
|
||
|
probes in a test required to have failed in order to
|
||
|
consider the test failed."
|
||
|
::= { pingNotifications 2 }
|
||
|
|
||
|
pingTestCompleted NOTIFICATION-TYPE
|
||
|
OBJECTS {
|
||
|
pingCtlTargetAddressType,
|
||
|
pingCtlTargetAddress,
|
||
|
pingResultsOperStatus,
|
||
|
pingResultsIpTargetAddressType,
|
||
|
pingResultsIpTargetAddress,
|
||
|
pingResultsMinRtt,
|
||
|
pingResultsMaxRtt,
|
||
|
pingResultsAverageRtt,
|
||
|
pingResultsProbeResponses,
|
||
|
pingResultsSentProbes,
|
||
|
pingResultsRttSumOfSquares,
|
||
|
pingResultsLastGoodProbe
|
||
|
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Generated at the completion of a ping test when the
|
||
|
corresponding pingCtlTrapGeneration object has the
|
||
|
testCompletion(2) bit set."
|
||
|
::= { pingNotifications 3 }
|
||
|
|
||
|
-- Conformance information
|
||
|
|
||
|
-- Compliance statements
|
||
|
|
||
|
pingCompliances OBJECT IDENTIFIER ::= { pingConformance 1 }
|
||
|
pingGroups OBJECT IDENTIFIER ::= { pingConformance 2 }
|
||
|
|
||
|
-- Compliance statements
|
||
|
|
||
|
pingFullCompliance MODULE-COMPLIANCE
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The compliance statement for SNMP entities that
|
||
|
fully implement the DISMAN-PING-MIB."
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS {
|
||
|
pingMinimumGroup,
|
||
|
pingCtlRowStatusGroup,
|
||
|
pingHistoryGroup,
|
||
|
pingNotificationsGroup
|
||
|
}
|
||
|
|
||
|
OBJECT pingMaxConcurrentRequests
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"The agent is not required to support set
|
||
|
operations to this object."
|
||
|
|
||
|
OBJECT pingCtlStorageType
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required."
|
||
|
|
||
|
OBJECT pingCtlType
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. In addition, the only
|
||
|
value that MUST be supported by an implementation is
|
||
|
pingIcmpEcho."
|
||
|
|
||
|
OBJECT pingCtlSourceAddressType
|
||
|
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access to this object is not required by
|
||
|
implementations that are not capable of binding the
|
||
|
send socket with a source address. An implementation
|
||
|
is only required to support IPv4 and IPv6 addresses."
|
||
|
|
||
|
OBJECT pingCtlSourceAddress
|
||
|
SYNTAX InetAddress (SIZE(0|4|16))
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access to this object is not required by
|
||
|
implementations that are not capable of binding the
|
||
|
send socket with a source address. An implementation
|
||
|
is only required to support IPv4 and IPv6 addresses."
|
||
|
|
||
|
OBJECT pingCtlIfIndex
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. If write access is
|
||
|
not supported, return a 0 as the value of this object.
|
||
|
A value of 0 means that the function represented by
|
||
|
this option is not supported."
|
||
|
|
||
|
OBJECT pingCtlByPassRouteTable
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access to this object is not required by
|
||
|
implementations that are not capable of its
|
||
|
implementation. The function represented by this
|
||
|
object is implementable if the setsockopt
|
||
|
SOL_SOCKET SO_DONTROUTE option is supported."
|
||
|
|
||
|
OBJECT pingCtlDSField
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. If write access is
|
||
|
not supported, return a 0 as the value of this object.
|
||
|
A value of 0 means that the function represented by
|
||
|
this option is not supported."
|
||
|
|
||
|
OBJECT pingResultsIpTargetAddressType
|
||
|
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
|
||
|
DESCRIPTION
|
||
|
"An implementation is only required to
|
||
|
|
||
|
support IPv4 and IPv6 addresses."
|
||
|
|
||
|
OBJECT pingResultsIpTargetAddress
|
||
|
SYNTAX InetAddress (SIZE(0|4|16))
|
||
|
DESCRIPTION
|
||
|
"An implementation is only required to
|
||
|
support IPv4 and globally unique IPv6 addresses."
|
||
|
|
||
|
OBJECT pingResultsLastGoodProbe
|
||
|
DESCRIPTION
|
||
|
"This object is mandatory for implementations that have
|
||
|
access to a system clock and that are capable of setting
|
||
|
the values for DateAndTime objects. It is RECOMMENDED
|
||
|
that when this object is not supported its values
|
||
|
be reported as '0000000000000000'H."
|
||
|
|
||
|
OBJECT pingProbeHistoryTime
|
||
|
DESCRIPTION
|
||
|
"This object is mandatory for implementations that have
|
||
|
access to a system clock and that are capable of setting
|
||
|
the values for DateAndTime objects. It is RECOMMENDED
|
||
|
that when this object is not supported its values
|
||
|
be reported as '0000000000000000'H."
|
||
|
::= { pingCompliances 2 }
|
||
|
|
||
|
pingMinimumCompliance MODULE-COMPLIANCE
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The minimum compliance statement for SNMP entities
|
||
|
that implement the minimal subset of the
|
||
|
DISMAN-PING-MIB. Implementors might choose this
|
||
|
subset for small devices with limited resources."
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS { pingMinimumGroup }
|
||
|
|
||
|
GROUP pingCtlRowStatusGroup
|
||
|
DESCRIPTION
|
||
|
"A compliant implementation does not have to implement
|
||
|
the pingCtlRowStatusGroup."
|
||
|
|
||
|
GROUP pingHistoryGroup
|
||
|
DESCRIPTION
|
||
|
"A compliant implementation does not have to implement
|
||
|
the pingHistoryGroup."
|
||
|
|
||
|
GROUP pingNotificationsGroup
|
||
|
DESCRIPTION
|
||
|
"A compliant implementation does not have to implement
|
||
|
|
||
|
the pingNotificationsGroup."
|
||
|
|
||
|
OBJECT pingMaxConcurrentRequests
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"The agent is not required to support set
|
||
|
operations to this object."
|
||
|
|
||
|
OBJECT pingCtlDataFill
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"The agent is not required to support set
|
||
|
operations to this object."
|
||
|
|
||
|
OBJECT pingCtlFrequency
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. If write access is
|
||
|
not supported, return a 0 as the value of this object.
|
||
|
A value of 0 means that the function represented by
|
||
|
this option is not supported."
|
||
|
|
||
|
OBJECT pingCtlMaxRows
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. If the
|
||
|
pingHistoryGroup is not implemented, then write
|
||
|
access to this object MUST be disabled, and the object
|
||
|
MUST return a value of 0 when retrieved."
|
||
|
|
||
|
OBJECT pingCtlStorageType
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required."
|
||
|
|
||
|
OBJECT pingCtlTrapGeneration
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. If the
|
||
|
pingNotificationsGroup is not implemented, then write
|
||
|
access to this object MUST be disabled, and the object
|
||
|
MUST return a value with no bit set when retrieved.
|
||
|
No bit set indicates that not notification is
|
||
|
generated."
|
||
|
|
||
|
OBJECT pingCtlTrapProbeFailureFilter
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"If write access to pingCtlTrapGeneration is not
|
||
|
supported, then write access to this object must also
|
||
|
not be supported. In this case, return 0 as the value
|
||
|
of this object."
|
||
|
|
||
|
OBJECT pingCtlTrapTestFailureFilter
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"If write access to pingCtlTrapGeneration is not
|
||
|
supported, then write access to this object must also
|
||
|
not be supported. In this case, return 0 as the value
|
||
|
of this object."
|
||
|
|
||
|
OBJECT pingCtlType
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. In addition, the only
|
||
|
value that MUST be supported by an implementation is
|
||
|
pingIcmpEcho."
|
||
|
|
||
|
OBJECT pingCtlDescr
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"The agent is not required to support set
|
||
|
operations to this object."
|
||
|
|
||
|
OBJECT pingCtlSourceAddressType
|
||
|
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access to this object is not required by
|
||
|
implementations that are not capable of binding the
|
||
|
send socket with a source address. An implementation
|
||
|
is only required to support IPv4 and IPv6 addresses."
|
||
|
|
||
|
OBJECT pingCtlSourceAddress
|
||
|
SYNTAX InetAddress (SIZE(0|4|16))
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access to this object is not required by
|
||
|
implementations that are not capable of binding the
|
||
|
send socket with a source address. An implementation
|
||
|
is only required to support IPv4 and IPv6 addresses."
|
||
|
|
||
|
OBJECT pingCtlIfIndex
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. If write access is
|
||
|
|
||
|
not supported, return a 0 as the value of this object.
|
||
|
A value of 0 means that the function represented by
|
||
|
this option is not supported."
|
||
|
|
||
|
OBJECT pingCtlByPassRouteTable
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. If write access is
|
||
|
not supported, return false(2) as the value of this
|
||
|
object. A value of false(2) means that the function
|
||
|
represented by this option is not supported."
|
||
|
|
||
|
OBJECT pingCtlDSField
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. If write access is
|
||
|
not supported, return a 0 as the value of this object.
|
||
|
A value of 0 means that the function represented by
|
||
|
this option is not supported."
|
||
|
|
||
|
OBJECT pingResultsIpTargetAddressType
|
||
|
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
|
||
|
DESCRIPTION
|
||
|
"An implementation is only required to
|
||
|
support IPv4 and IPv6 addresses."
|
||
|
|
||
|
OBJECT pingResultsIpTargetAddress
|
||
|
SYNTAX InetAddress (SIZE(0|4|16))
|
||
|
DESCRIPTION
|
||
|
"An implementation is only required to
|
||
|
support IPv4 and globally unique IPv6 addresses."
|
||
|
|
||
|
OBJECT pingResultsLastGoodProbe
|
||
|
DESCRIPTION
|
||
|
"This object is mandatory for implementations that have
|
||
|
access to a system clock and that are capable of setting
|
||
|
the values for DateAndTime objects. It is RECOMMENDED
|
||
|
that when this object is not supported its values
|
||
|
be reported as '0000000000000000'H."
|
||
|
|
||
|
OBJECT pingProbeHistoryTime
|
||
|
DESCRIPTION
|
||
|
"If the pingHistoryGroup is implemented, then this
|
||
|
object is mandatory for implementations that have
|
||
|
access to a system clock and that are capable of setting
|
||
|
the values for DateAndTime objects. It is RECOMMENDED
|
||
|
that when this object is not supported its values
|
||
|
|
||
|
be reported as '0000000000000000'H."
|
||
|
::= { pingCompliances 3 }
|
||
|
|
||
|
pingCompliance MODULE-COMPLIANCE
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The compliance statement for the DISMAN-PING-MIB. This
|
||
|
compliance statement has been deprecated because the
|
||
|
group pingGroup and the pingTimeStampGroup have been
|
||
|
split and deprecated. The pingFullCompliance statement
|
||
|
is semantically identical to the deprecated
|
||
|
pingCompliance statement."
|
||
|
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS {
|
||
|
pingGroup,
|
||
|
pingNotificationsGroup
|
||
|
}
|
||
|
GROUP pingTimeStampGroup
|
||
|
DESCRIPTION
|
||
|
"This group is mandatory for implementations that have
|
||
|
access to a system clock and that are capable of setting
|
||
|
the values for DateAndTime objects. It is RECOMMENDED
|
||
|
that when this group is not supported the values
|
||
|
for the objects in this group be reported as
|
||
|
'0000000000000000'H."
|
||
|
|
||
|
OBJECT pingMaxConcurrentRequests
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"The agent is not required to support set
|
||
|
operations to this object."
|
||
|
|
||
|
OBJECT pingCtlStorageType
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. It is also allowed
|
||
|
that implementations support only the volatile
|
||
|
StorageType enumeration."
|
||
|
|
||
|
OBJECT pingCtlType
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. In addition, the only
|
||
|
value that MUST be supported by an implementation is
|
||
|
pingIcmpEcho."
|
||
|
|
||
|
OBJECT pingCtlByPassRouteTable
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"This object is not required by implementations that
|
||
|
are not capable of its implementation. The function
|
||
|
represented by this object is implementable if the
|
||
|
setsockopt SOL_SOCKET SO_DONTROUTE option is
|
||
|
supported."
|
||
|
|
||
|
OBJECT pingCtlSourceAddressType
|
||
|
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"This object is not required by implementations that
|
||
|
are not capable of binding the send socket with a
|
||
|
source address. An implementation is only required to
|
||
|
support IPv4 and IPv6 addresses."
|
||
|
|
||
|
OBJECT pingCtlSourceAddress
|
||
|
SYNTAX InetAddress (SIZE(0|4|16))
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"This object is not required by implementations that
|
||
|
are not capable of binding the send socket with a
|
||
|
source address. An implementation is only required to
|
||
|
support IPv4 and globally unique IPv6 addresses."
|
||
|
|
||
|
OBJECT pingCtlIfIndex
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. When write access is
|
||
|
not supported, return a 0 as the value of this object.
|
||
|
A value of 0 means that the function represented by
|
||
|
this option is not supported."
|
||
|
|
||
|
OBJECT pingCtlDSField
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"Write access is not required. When write access is
|
||
|
not supported, return a 0 as the value of this object.
|
||
|
A value of 0 means that the function represented by
|
||
|
this option is not supported."
|
||
|
|
||
|
OBJECT pingResultsIpTargetAddressType
|
||
|
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
|
||
|
DESCRIPTION
|
||
|
"An implementation is only required to
|
||
|
support IPv4 and IPv6 addresses."
|
||
|
|
||
|
OBJECT pingResultsIpTargetAddress
|
||
|
SYNTAX InetAddress (SIZE(0|4|16))
|
||
|
DESCRIPTION
|
||
|
"An implementation is only required to
|
||
|
support IPv4 and globally unique IPv6 addresses."
|
||
|
::= { pingCompliances 1 }
|
||
|
|
||
|
-- MIB groupings
|
||
|
|
||
|
pingMinimumGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
pingMaxConcurrentRequests,
|
||
|
pingCtlTargetAddressType,
|
||
|
pingCtlTargetAddress,
|
||
|
pingCtlDataSize,
|
||
|
pingCtlTimeOut,
|
||
|
pingCtlProbeCount,
|
||
|
pingCtlAdminStatus,
|
||
|
pingCtlDataFill,
|
||
|
pingCtlFrequency,
|
||
|
pingCtlMaxRows,
|
||
|
pingCtlStorageType,
|
||
|
pingCtlTrapGeneration,
|
||
|
pingCtlTrapProbeFailureFilter,
|
||
|
pingCtlTrapTestFailureFilter,
|
||
|
pingCtlType,
|
||
|
pingCtlDescr,
|
||
|
pingCtlByPassRouteTable,
|
||
|
pingCtlSourceAddressType,
|
||
|
pingCtlSourceAddress,
|
||
|
pingCtlIfIndex,
|
||
|
pingCtlDSField,
|
||
|
pingResultsOperStatus,
|
||
|
pingResultsIpTargetAddressType,
|
||
|
pingResultsIpTargetAddress,
|
||
|
pingResultsMinRtt,
|
||
|
pingResultsMaxRtt,
|
||
|
pingResultsAverageRtt,
|
||
|
pingResultsProbeResponses,
|
||
|
pingResultsSentProbes,
|
||
|
pingResultsRttSumOfSquares,
|
||
|
pingResultsLastGoodProbe
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The group of objects that constitute the remote ping
|
||
|
capability."
|
||
|
::= { pingGroups 4 }
|
||
|
|
||
|
pingCtlRowStatusGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
pingCtlRowStatus
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The RowStatus object of the pingCtlTable."
|
||
|
::= { pingGroups 5 }
|
||
|
|
||
|
pingHistoryGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
pingProbeHistoryResponse,
|
||
|
pingProbeHistoryStatus,
|
||
|
pingProbeHistoryLastRC,
|
||
|
pingProbeHistoryTime
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The group of objects that constitute the history
|
||
|
capability."
|
||
|
::= { pingGroups 6 }
|
||
|
|
||
|
pingNotificationsGroup NOTIFICATION-GROUP
|
||
|
NOTIFICATIONS {
|
||
|
pingProbeFailed,
|
||
|
pingTestFailed,
|
||
|
pingTestCompleted
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The notification that are required to be supported by
|
||
|
implementations of this MIB."
|
||
|
::= { pingGroups 3 }
|
||
|
|
||
|
pingGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
pingMaxConcurrentRequests,
|
||
|
pingCtlTargetAddressType,
|
||
|
pingCtlTargetAddress,
|
||
|
pingCtlDataSize,
|
||
|
pingCtlTimeOut,
|
||
|
pingCtlProbeCount,
|
||
|
pingCtlAdminStatus,
|
||
|
pingCtlDataFill,
|
||
|
pingCtlFrequency,
|
||
|
pingCtlMaxRows,
|
||
|
pingCtlStorageType,
|
||
|
pingCtlTrapGeneration,
|
||
|
pingCtlTrapProbeFailureFilter,
|
||
|
pingCtlTrapTestFailureFilter,
|
||
|
pingCtlType,
|
||
|
pingCtlDescr,
|
||
|
pingCtlByPassRouteTable,
|
||
|
pingCtlSourceAddressType,
|
||
|
pingCtlSourceAddress,
|
||
|
pingCtlIfIndex,
|
||
|
pingCtlDSField,
|
||
|
pingCtlRowStatus,
|
||
|
pingResultsOperStatus,
|
||
|
pingResultsIpTargetAddressType,
|
||
|
pingResultsIpTargetAddress,
|
||
|
pingResultsMinRtt,
|
||
|
pingResultsMaxRtt,
|
||
|
pingResultsAverageRtt,
|
||
|
pingResultsProbeResponses,
|
||
|
pingResultsSentProbes,
|
||
|
pingResultsRttSumOfSquares,
|
||
|
pingProbeHistoryResponse,
|
||
|
pingProbeHistoryStatus,
|
||
|
pingProbeHistoryLastRC
|
||
|
}
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The group of objects that constitute the remote ping
|
||
|
capability."
|
||
|
::= { pingGroups 1 }
|
||
|
|
||
|
pingTimeStampGroup OBJECT-GROUP
|
||
|
|
||
|
OBJECTS {
|
||
|
pingResultsLastGoodProbe,
|
||
|
pingProbeHistoryTime
|
||
|
}
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The group of DateAndTime objects."
|
||
|
::= { pingGroups 2 }
|
||
|
|
||
|
END
|