Printer-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, TimeTicks,
|
||
|
NOTIFICATION-TYPE, OBJECT-IDENTITY,
|
||
|
mib-2 FROM SNMPv2-SMI -- [RFC2578]
|
||
|
TEXTUAL-CONVENTION FROM SNMPv2-TC -- [RFC2579]
|
||
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
||
|
FROM SNMPv2-CONF -- [RFC2580]
|
||
|
hrDeviceIndex, hrStorageIndex FROM HOST-RESOURCES-MIB -- [RFC2790]
|
||
|
InterfaceIndexOrZero FROM IF-MIB -- [RFC2863]
|
||
|
PrtCoverStatusTC, PrtGeneralResetTC, PrtChannelTypeTC,
|
||
|
PrtInterpreterLangFamilyTC, PrtInputTypeTC, PrtOutputTypeTC,
|
||
|
PrtMarkerMarkTechTC, PrtMarkerSuppliesTypeTC, PrtConsoleColorTC,
|
||
|
PrtConsoleDisableTC, PrtMediaPathTypeTC, PrtAlertGroupTC,
|
||
|
PrtAlertTrainingLevelTC, PrtAlertCodeTC
|
||
|
FROM IANA-PRINTER-MIB
|
||
|
IANACharset FROM IANA-CHARSET-MIB;
|
||
|
|
||
|
printmib MODULE-IDENTITY
|
||
|
LAST-UPDATED "0406020000Z"
|
||
|
ORGANIZATION "PWG IEEE/ISTO Printer Working Group"
|
||
|
CONTACT-INFO
|
||
|
"Harry Lewis
|
||
|
IBM
|
||
|
Phone (303) 924-5337
|
||
|
Email: harryl@us.ibm.com
|
||
|
http://www.pwg.org/index.html
|
||
|
|
||
|
Send comments to the printmib WG using the Printer MIB
|
||
|
Project (PMP) Mailing List: pmp@pwg.org
|
||
|
|
||
|
For further information, access the PWG web page under 'Printer
|
||
|
MIB': http://www.pwg.org/
|
||
|
|
||
|
Implementers of this specification are encouraged to join the
|
||
|
pmp mailing list in order to participate in discussions on any
|
||
|
clarifications needed and registration proposals being reviewed
|
||
|
in order to achieve consensus."
|
||
|
DESCRIPTION
|
||
|
"The MIB module for management of printers.
|
||
|
Copyright (C) The Internet Society (2004). This
|
||
|
version of this MIB module was published
|
||
|
in RFC 3805. For full legal notices see the RFC itself."
|
||
|
REVISION "200406020000Z"
|
||
|
DESCRIPTION
|
||
|
"Printer MIB v2.
|
||
|
Moved all enum groups to be maintained by IANA into new TCs
|
||
|
within the ianaPrinterMIB, which is contained in this
|
||
|
document.
|
||
|
New TCs created from enums defined within RFC 1759 Objects:
|
||
|
PrtPrintOrientationTC, PrtLocalizedDescriptionStringTC,
|
||
|
PrtConsoleDescriptionStringTC, PrtChannelStateTC,
|
||
|
PrtOutputStackingOrderTC, PrtOutputPageDeliveryOrientationTC,
|
||
|
PrtMarkerCounterUnitTC, PrtMarkerSuppliesSupplyUnitTC,
|
||
|
PrtMarkerSuppliesClassTC, PrtMarkerAddressabilityUnitTC,
|
||
|
PrtMarkerColorantRoleTC, PrtMediaPathMaxSpeedPrintUnitTC,
|
||
|
PrtInterpreterTwoWayTC, and PrtAlertSeverityLevelTC.
|
||
|
The following four TCs have been deprecated:
|
||
|
MediaUnit (replaced by PrtMediaUnitTC),
|
||
|
CapacityUnit (replaced by PrtCapacityUnitTC),
|
||
|
SubUnitStatus (replaced by PrtSubUnitStatusTC),
|
||
|
CodedCharSet (replaced by IANACharset in IANA Charset MIB)
|
||
|
Five new OBJECT-GROUPs: prtAuxilliarySheetGroup,
|
||
|
prtInputSwitchingGroup, prtGeneralV2Group,
|
||
|
prtAlertTableV2Group, prtChannelV2Group.
|
||
|
Nine new objects added to those groups:
|
||
|
prtAuxiliarySheetStartupPage, prtAuxiliarySheetBannerPage,
|
||
|
prtGeneralPrinterName, prtGeneralSerialNumber,
|
||
|
prtAlertCriticalEvents, prtAlertAllEvents,
|
||
|
prtInputMediaLoadTimeout, prtInputNextIndex,
|
||
|
prtChannelInformation.
|
||
|
SYNTAX range changed from (0..65535) to (1..65535) for the
|
||
|
index objects prtStorageRefSeqNumber, prtDeviceRefSeqNumber,
|
||
|
and prtConsoleLightIndex.
|
||
|
SYNTAX range changed from (0..65535) to (0..2147483647) for the
|
||
|
objects prtStorageRefIndex and prtDeviceRefIndex to agree
|
||
|
with the Host Resources MIB.
|
||
|
Defined a range for the objects with a SYNTAX of Integer32:
|
||
|
prtOutputDefaultIndex, prtInputMediaDimFeedDirDeclared,
|
||
|
prtInputMediaDimXFeedDirDeclared, prtInputMaxCapacity,
|
||
|
prtInputCurrentLevel, prtInputMediaDimFeedDirChosen,
|
||
|
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
|
||
|
prtInputMediaFormParts, prtOutputIndex,
|
||
|
prtOutputMaxCapacity, prtOutputRemainingCapacity,
|
||
|
prtOutputMaxDimFeedDir, prtOutputMaxDimXFeedDir,
|
||
|
prtOutputMinDimFeedDir, prtOutputMinDimXFeedDir,
|
||
|
prtMarkerAddressibilityFeedDir,
|
||
|
prtMarkerAddressibilityXFeedDir, prtMarkerNorthMargin,
|
||
|
prtMarkerSouthMargin, prtMarkerWestMargin,
|
||
|
prtMarkerEastMargin, prtMarkerSuppliesMaxCapacity,
|
||
|
prtMarkerSuppliesLevel, prtMarkerColorantTonality,
|
||
|
prtMediaPathMaxSpeed, prtMediaPathMaxMediaFeedDir,
|
||
|
prtMediaPathMaxMediaXFeedDir, prtMediaPathMinMediaFeedDir,
|
||
|
prtMediaPathMinMediaXFeedDir, prtChannelIndex,
|
||
|
prtChannelCurrentJobCntlLangIndex, prtInterpreterIndex,
|
||
|
prtChannelDefaultPageDescLangIndex, prtConsoleOnTime,
|
||
|
prtInterpreterFeedAddressibility, prtConsoleOffTime,
|
||
|
prtInterpreterXFeedAddressibility, prtAlertIndex,
|
||
|
prtAlertGroupIndex, prtAlertLocation.
|
||
|
Changed SYNTAX from Integer32 to InterfaceIndexOrZero for
|
||
|
prtChannelIfIndex.
|
||
|
Changed MAX-ACCESS of prtAlertIndex from not-accessible to
|
||
|
Read-only and added a compliance statement to allow a
|
||
|
MIN-ACCESS of accessible-for-notify.
|
||
|
One new NOTIFICATION-GROUP: prtAlertTrapGroup which contains
|
||
|
printerV2Alert.
|
||
|
In MODULE-COMPLIANCE prtMIBCompliance, new OBJECT-GROUPs and
|
||
|
the NOTIFICATION_GROUP, all in GROUP (not MANDATORY-GROUP)
|
||
|
clauses. The nine new objects are optional, i.e., this
|
||
|
document is backward compatible with RFC 1759."
|
||
|
REVISION "9411250000Z"
|
||
|
DESCRIPTION
|
||
|
"The original version of this MIB, published as RFC1759."
|
||
|
::= { mib-2 43 }
|
||
|
|
||
|
-- TEXTUAL-CONVENTIONs for this MIB module
|
||
|
--
|
||
|
-- Generic unspecific TEXTUAL-CONVENTIONs
|
||
|
--
|
||
|
|
||
|
PrtMediaUnitTC ::= TEXTUAL-CONVENTION
|
||
|
-- Replaces MediaUnit in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Units of measure for media dimensions."
|
||
|
SYNTAX INTEGER {
|
||
|
tenThousandthsOfInches(3), -- .0001
|
||
|
micrometers(4)
|
||
|
}
|
||
|
|
||
|
MediaUnit ::= TEXTUAL-CONVENTION
|
||
|
-- Replaced by PrtMediaUnitTC.
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"Units of measure for media dimensions."
|
||
|
SYNTAX INTEGER {
|
||
|
tenThousandthsOfInches(3), -- .0001
|
||
|
micrometers(4)
|
||
|
}
|
||
|
|
||
|
PrtCapacityUnitTC ::= TEXTUAL-CONVENTION
|
||
|
-- Replaces CapacityUnit in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Units of measure for media capacity."
|
||
|
SYNTAX INTEGER {
|
||
|
other(1), -- New, not in RFC 1759
|
||
|
unknown(2), -- New, not in RFC 1759
|
||
|
tenThousandthsOfInches(3), -- .0001
|
||
|
micrometers(4),
|
||
|
sheets(8),
|
||
|
feet(16),
|
||
|
meters(17),
|
||
|
-- Values for Finisher MIB
|
||
|
items(18), -- New, not in RFC 1759
|
||
|
percent(19) -- New, not in RFC 1759
|
||
|
}
|
||
|
|
||
|
CapacityUnit ::= TEXTUAL-CONVENTION
|
||
|
-- Replaced by PrtCapacityUnitTC.
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"Units of measure for media capacity."
|
||
|
SYNTAX INTEGER {
|
||
|
tenThousandthsOfInches(3), -- .0001
|
||
|
micrometers(4),
|
||
|
sheets(8),
|
||
|
feet(16),
|
||
|
meters(17)
|
||
|
}
|
||
|
|
||
|
PrtPrintOrientationTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtInterpreterDefaultOrientation in
|
||
|
-- RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A generic representation for printing orientation on a
|
||
|
'page'."
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
portrait(3),
|
||
|
landscape(4)
|
||
|
}
|
||
|
|
||
|
PrtSubUnitStatusTC ::= TEXTUAL-CONVENTION
|
||
|
-- Replaces SubUnitStatus in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Status of a printer sub-unit.
|
||
|
|
||
|
The SubUnitStatus is an integer that is the sum of 5 distinct
|
||
|
values, Availability, Non-Critical, Critical, On-line, and
|
||
|
Transitioning. These values are:
|
||
|
|
||
|
Availability Value
|
||
|
|
||
|
Available and Idle 0 0000'b
|
||
|
Available and Standby 2 0010'b
|
||
|
Available and Active 4 0100'b
|
||
|
Available and Busy 6 0110'b
|
||
|
Unavailable and OnRequest 1 0001'b
|
||
|
Unavailable because Broken 3 0011'b
|
||
|
Unknown 5 0101'b
|
||
|
|
||
|
Non-Critical
|
||
|
No Non-Critical Alerts 0 0000'b
|
||
|
Non-Critical Alerts 8 1000'b
|
||
|
|
||
|
Critical
|
||
|
|
||
|
No Critical Alerts 0 0000'b
|
||
|
Critical Alerts 16 1 0000'b
|
||
|
|
||
|
On-Line
|
||
|
|
||
|
State is On-Line 0 0000'b
|
||
|
State is Off-Line 32 10 0000'b
|
||
|
|
||
|
Transitioning
|
||
|
|
||
|
At intended state 0 0000'b
|
||
|
Transitioning to intended state 64 100 0000'b"
|
||
|
|
||
|
SYNTAX INTEGER (0..126)
|
||
|
|
||
|
SubUnitStatus ::= TEXTUAL-CONVENTION
|
||
|
-- Replaced by PrtSubUnitStatusTC.
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"Status of a printer sub-unit.
|
||
|
|
||
|
The SubUnitStatus is an integer that is the sum of 5 distinct
|
||
|
values, Availability, Non-Critical, Critical, On-line, and
|
||
|
Transitioning. These values are:
|
||
|
|
||
|
Availability Value
|
||
|
Available and Idle 0 0000'b
|
||
|
Available and Standby 2 0010'b
|
||
|
Available and Active 4 0100'b
|
||
|
Available and Busy 6 0110'b
|
||
|
Unavailable and OnRequest 1 0001'b
|
||
|
Unavailable because Broken 3 0011'b
|
||
|
Unknown 5 0101'b
|
||
|
|
||
|
Non-Critical
|
||
|
No Non-Critical Alerts 0 0000'b
|
||
|
Non-Critical Alerts 8 1000'b
|
||
|
|
||
|
Critical
|
||
|
|
||
|
No Critical Alerts 0 0000'b
|
||
|
Critical Alerts 16 1 0000'b
|
||
|
|
||
|
On-Line
|
||
|
|
||
|
State is On-Line 0 0000'b
|
||
|
State is Off-Line 32 10 0000'b
|
||
|
|
||
|
Transitioning
|
||
|
At intended state 0 0000'b
|
||
|
Transitioning to intended state 64 100 0000'b"
|
||
|
|
||
|
SYNTAX INTEGER (0..126)
|
||
|
|
||
|
PresentOnOff ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Presence and configuration of a device or feature."
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
on(3),
|
||
|
off(4),
|
||
|
notPresent(5)
|
||
|
}
|
||
|
|
||
|
PrtLocalizedDescriptionStringTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC did not appear in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An object MUST use this TEXTUAL-CONVENTION when its
|
||
|
'charset' is controlled by the value of
|
||
|
prtGeneralCurrentLocalization."
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
|
||
|
PrtConsoleDescriptionStringTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC did not appear in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An object MUST use this TEXTUAL-CONVENTION when its
|
||
|
'charset' is controlled by the value of
|
||
|
prtConsoleLocalization."
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
|
||
|
CodedCharSet ::= TEXTUAL-CONVENTION
|
||
|
|
||
|
-- Replaced by IANACharset TEXTUAL-CONVENTION in IANA Charset MIB.
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The original description clause from RFC 1759 [RFC1759] was
|
||
|
technically inaccurate and therefore has been deleted."
|
||
|
SYNTAX INTEGER {
|
||
|
other(1) -- used if the designated coded
|
||
|
-- character set is not currently in
|
||
|
-- the enumeration
|
||
|
}
|
||
|
|
||
|
--
|
||
|
-- Channel Group TEXTUAL-CONVENTIONs
|
||
|
--
|
||
|
|
||
|
PrtChannelStateTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtChannelState in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The state of this print job delivery channel. The value
|
||
|
determines whether print data is allowed through this channel."
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
printDataAccepted(3),
|
||
|
noDataAccepted(4)
|
||
|
}
|
||
|
|
||
|
--
|
||
|
-- Input/Output Group TEXTUAL-CONVENTIONs
|
||
|
--
|
||
|
|
||
|
PrtOutputStackingOrderTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtOutputStackingOrder in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current state of the stacking order for the associated
|
||
|
output sub-unit. 'firstToLast' means that as pages are output,
|
||
|
the front of the next page is placed against the back of the
|
||
|
previous page. 'lastToFirst' means that as pages are output,
|
||
|
the back of the next page is placed against the front of the
|
||
|
previous page."
|
||
|
SYNTAX INTEGER {
|
||
|
unknown(2),
|
||
|
firstToLast(3),
|
||
|
lastToFirst(4)
|
||
|
}
|
||
|
|
||
|
PrtOutputPageDeliveryOrientationTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtOutputPageDeliveryOrientation
|
||
|
-- in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The reading surface that will be 'up' when pages are delivered
|
||
|
to the associated output sub-unit. Values are Face-Up and Face
|
||
|
Down (Note: interpretation of these values is, in general,
|
||
|
context-dependent based on locale; presentation of these values
|
||
|
to an end-user should be normalized to the expectations of the
|
||
|
user."
|
||
|
SYNTAX INTEGER {
|
||
|
faceUp(3),
|
||
|
faceDown(4)
|
||
|
}
|
||
|
|
||
|
--
|
||
|
-- Marker Group TEXTUAL-CONVENTIONs
|
||
|
--
|
||
|
|
||
|
PrtMarkerCounterUnitTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtMarkerCounterUnit in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The unit that will be used by the printer when reporting
|
||
|
counter values for this marking sub-unit. The
|
||
|
time units of measure are provided for a device like a
|
||
|
strip recorder that does not or cannot track the physical
|
||
|
dimensions of the media and does not use characters,
|
||
|
lines or sheets."
|
||
|
|
||
|
SYNTAX INTEGER {
|
||
|
tenThousandthsOfInches(3), -- .0001
|
||
|
micrometers(4),
|
||
|
characters(5),
|
||
|
lines(6),
|
||
|
impressions(7),
|
||
|
sheets(8),
|
||
|
dotRow(9),
|
||
|
hours(11),
|
||
|
feet(16),
|
||
|
meters(17)
|
||
|
}
|
||
|
|
||
|
PrtMarkerSuppliesSupplyUnitTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtMarkerSuppliesSupplyUnit
|
||
|
-- in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Unit of this marker supply container/receptacle."
|
||
|
SYNTAX INTEGER {
|
||
|
other(1), -- New, not in RFC 1759
|
||
|
unknown(2), -- New, not in RFC 1759
|
||
|
tenThousandthsOfInches(3), -- .0001
|
||
|
micrometers(4),
|
||
|
impressions(7), -- New, not in RFC 1759
|
||
|
sheets(8), -- New, not in RFC 1759
|
||
|
hours(11), -- New, not in RFC 1759
|
||
|
thousandthsOfOunces(12),
|
||
|
tenthsOfGrams(13),
|
||
|
hundrethsOfFluidOunces(14),
|
||
|
tenthsOfMilliliters(15),
|
||
|
feet(16), -- New, not in RFC 1759
|
||
|
meters(17), -- New, not in RFC 1759
|
||
|
-- Values for Finisher MIB
|
||
|
items(18), -- e.g., #staples. New, not in RFC 1759
|
||
|
percent(19) -- New, not in RFC 1759
|
||
|
}
|
||
|
|
||
|
PrtMarkerSuppliesClassTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtMarkerSuppliesClass in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates whether this supply entity represents a supply
|
||
|
that is consumed or a receptacle that is filled."
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
supplyThatIsConsumed(3),
|
||
|
receptacleThatIsFilled(4)
|
||
|
}
|
||
|
|
||
|
PrtMarkerColorantRoleTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtMarkerColorantRole in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The role played by this colorant."
|
||
|
SYNTAX INTEGER { -- Colorant Role
|
||
|
other(1),
|
||
|
process(3),
|
||
|
spot(4)
|
||
|
}
|
||
|
|
||
|
PrtMarkerAddressabilityUnitTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtMarkerAddressabilityUnit
|
||
|
-- in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The unit of measure of distances, as applied to the marker's
|
||
|
resolution."
|
||
|
SYNTAX INTEGER {
|
||
|
tenThousandthsOfInches(3), -- .0001
|
||
|
micrometers(4)
|
||
|
}
|
||
|
|
||
|
--
|
||
|
-- Media Path TEXTUAL-CONVENTIONs
|
||
|
--
|
||
|
|
||
|
PrtMediaPathMaxSpeedPrintUnitTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtMediaPathMaxSpeedPrintUnit
|
||
|
-- in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The unit of measure used in specifying the speed of all
|
||
|
media paths in the printer."
|
||
|
SYNTAX INTEGER {
|
||
|
tenThousandthsOfInchesPerHour(3),-- .0001/hour
|
||
|
micrometersPerHour(4),
|
||
|
charactersPerHour(5),
|
||
|
linesPerHour(6),
|
||
|
impressionsPerHour(7),
|
||
|
sheetsPerHour(8),
|
||
|
dotRowPerHour(9),
|
||
|
feetPerHour(16),
|
||
|
metersPerHour(17)
|
||
|
}
|
||
|
|
||
|
--
|
||
|
-- Interpreter Group TEXTUAL-CONVENTIONs
|
||
|
--
|
||
|
|
||
|
PrtInterpreterTwoWayTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtInterpreterTwoWay in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates whether or not this interpreter returns information
|
||
|
back to the host."
|
||
|
SYNTAX INTEGER {
|
||
|
yes(3),
|
||
|
no(4)
|
||
|
}
|
||
|
|
||
|
--
|
||
|
-- Alert Group TEXTUAL-CONVENTIONs
|
||
|
--
|
||
|
|
||
|
PrtAlertSeverityLevelTC ::= TEXTUAL-CONVENTION
|
||
|
-- This TC was extracted from prtAlertSeverityLevel in RFC 1759.
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The level of severity of this alert table entry. The printer
|
||
|
determines the severity level assigned to each entry in the
|
||
|
table. A critical alert is binary by nature and definition. A
|
||
|
warning is defined to be a non-critical alert. The original and
|
||
|
most common warning is unary. The binary warning was added later
|
||
|
and given a more distinguished name."
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
critical(3),
|
||
|
warning(4),
|
||
|
warningBinaryChangeEvent(5) -- New, not in RFC 1759
|
||
|
}
|
||
|
|
||
|
-- The General Printer Group
|
||
|
--
|
||
|
-- The general printer sub-unit is responsible for the overall
|
||
|
-- control and status of the printer. There is exactly one
|
||
|
-- general printer sub-unit in a printer.
|
||
|
|
||
|
prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }
|
||
|
|
||
|
prtGeneralTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtGeneralEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A table of general information per printer.
|
||
|
Objects in this table are defined in various
|
||
|
places in the MIB, nearby the groups to
|
||
|
which they apply. They are all defined
|
||
|
here to minimize the number of tables that would
|
||
|
otherwise need to exist."
|
||
|
::= { prtGeneral 1 }
|
||
|
|
||
|
prtGeneralEntry OBJECT-TYPE
|
||
|
SYNTAX PrtGeneralEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry exists in this table for each device entry in the
|
||
|
host resources MIB device table with a device type of
|
||
|
'printer'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex }
|
||
|
::= { prtGeneralTable 1 }
|
||
|
|
||
|
PrtGeneralEntry ::= SEQUENCE {
|
||
|
-- Note that not all of the objects in this sequence are in
|
||
|
-- the general printer group. The group to which an
|
||
|
-- object belongs is tagged with a label "General", "Input"
|
||
|
-- "Output", etc. after each entry in the following sequence.
|
||
|
--
|
||
|
prtGeneralConfigChanges Counter32, -- General
|
||
|
prtGeneralCurrentLocalization Integer32, -- General
|
||
|
prtGeneralReset PrtGeneralResetTC,
|
||
|
-- General
|
||
|
prtGeneralCurrentOperator OCTET STRING,
|
||
|
-- Responsible Party
|
||
|
prtGeneralServicePerson OCTET STRING,
|
||
|
-- Responsible Party
|
||
|
prtInputDefaultIndex Integer32, -- Input
|
||
|
prtOutputDefaultIndex Integer32, -- Output
|
||
|
prtMarkerDefaultIndex Integer32, -- Marker
|
||
|
prtMediaPathDefaultIndex Integer32, -- Media Path
|
||
|
prtConsoleLocalization Integer32, -- Console
|
||
|
prtConsoleNumberOfDisplayLines Integer32, -- Console
|
||
|
prtConsoleNumberOfDisplayChars Integer32, -- Console
|
||
|
prtConsoleDisable PrtConsoleDisableTC,
|
||
|
-- Console,
|
||
|
prtAuxiliarySheetStartupPage PresentOnOff,
|
||
|
-- AuxiliarySheet
|
||
|
prtAuxiliarySheetBannerPage PresentOnOff,
|
||
|
-- AuxiliarySheet
|
||
|
prtGeneralPrinterName OCTET STRING,
|
||
|
-- General V2
|
||
|
prtGeneralSerialNumber OCTET STRING,
|
||
|
-- General V2
|
||
|
prtAlertCriticalEvents Counter32, -- Alert V2
|
||
|
prtAlertAllEvents Counter32 -- Alert V2
|
||
|
}
|
||
|
|
||
|
prtGeneralConfigChanges OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Counts configuration changes within the printer. A
|
||
|
configuration change is defined to be an action that results in
|
||
|
a change to any MIB object other than those that reflect status
|
||
|
or level, or those that act as counters or gauges. In addition,
|
||
|
any action that results in a row being added or deleted from
|
||
|
any table in the Printer MIB is considered a configuration
|
||
|
change. Such changes will often affect the capability of the
|
||
|
printer to service certain types of print jobs. Management
|
||
|
applications may cache infrequently changed configuration
|
||
|
information about sub units within the printer. This object
|
||
|
should be incremented whenever the agent wishes to notify
|
||
|
management applications that any cached configuration
|
||
|
information for this device is to be considered 'stale'. At
|
||
|
this point, the management application should flush any
|
||
|
configuration information cached about this device and fetch
|
||
|
new configuration information.
|
||
|
|
||
|
The following are examples of actions that would cause the
|
||
|
prtGeneralConfigChanges object to be incremented:
|
||
|
|
||
|
- Adding an output bin
|
||
|
- Changing the media in a sensing input tray
|
||
|
- Changing the value of prtInputMediaType
|
||
|
|
||
|
Note that the prtGeneralConfigChanges counter would not be
|
||
|
incremented when an input tray is temporarily removed to load
|
||
|
additional paper or when the level of an input device changes.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
|
||
|
::= { prtGeneralEntry 1 }
|
||
|
|
||
|
prtGeneralCurrentLocalization OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of the prtLocalizationIndex corresponding to the
|
||
|
current language, country, and character set to be used for
|
||
|
localized string values that are identified as being dependent
|
||
|
on the value of this object. Note that this object does not
|
||
|
apply to localized strings in the prtConsole group or to any
|
||
|
object that is not explicitly identified as being localized
|
||
|
according to prtGeneralCurrentLocalization. When an object's
|
||
|
'charset' is controlled by the value of
|
||
|
prtGeneralCurrentLocalization, it MUST specify
|
||
|
PrtLocalizedDescriptionStringTC as its syntax.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtGeneralEntry 2 }
|
||
|
|
||
|
prtGeneralReset OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly defined
|
||
|
-- by this object.
|
||
|
SYNTAX PrtGeneralResetTC
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Setting this value to 'powerCycleReset', 'resetToNVRAM', or
|
||
|
'resetToFactoryDefaults' will result in the resetting of the
|
||
|
printer. When read, this object will always have the value
|
||
|
'notResetting(3)', and a SET of the value 'notResetting' shall
|
||
|
have no effect on the printer. Some of the defined values are
|
||
|
optional. However, every implementation must support at least
|
||
|
the values 'notResetting' and 'resetToNVRAM'."
|
||
|
::= { prtGeneralEntry 3 }
|
||
|
|
||
|
-- The Responsible Party group
|
||
|
|
||
|
prtGeneralCurrentOperator OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..127))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The name of the person who is responsible for operating
|
||
|
this printer. It is suggested that this string include
|
||
|
information that would enable other humans to reach the
|
||
|
operator, such as a phone number. As a convention to
|
||
|
facilitate automatic notification of the operator by the
|
||
|
agent or network management station, the phone number,
|
||
|
fax number or email address should be indicated by the
|
||
|
URL schemes 'tel:', 'fax:' and 'mailto:', respectively.
|
||
|
If either the phone, fax, or email information is not
|
||
|
available, then a line should not be included for this
|
||
|
information.
|
||
|
|
||
|
NOTE: For interoperability purposes, it is advisable to
|
||
|
use email addresses formatted according to [RFC2822]
|
||
|
requirements.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtGeneralEntry 4 }
|
||
|
|
||
|
prtGeneralServicePerson OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..127))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The name of the person responsible for servicing this
|
||
|
printer. It is suggested that this string include
|
||
|
information that would enable other humans to reach the
|
||
|
service person, such as a phone number. As a convention
|
||
|
to facilitate automatic notification of the operator by
|
||
|
the agent or network management station, the phone
|
||
|
number, fax number or email address should be indicated
|
||
|
by the URL schemes 'tel:', 'fax:' and 'mailto:',
|
||
|
respectively. If either the phone, fax, or email
|
||
|
information is not available, then a line should not
|
||
|
be included for this information.
|
||
|
|
||
|
NOTE: For interoperability purposes, it is advisable to use
|
||
|
email addresses formatted per [RFC2822] requirements.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
|
||
|
::= { prtGeneralEntry 5 }
|
||
|
|
||
|
-- Default indexes section
|
||
|
--
|
||
|
-- The following four objects are used to specify the indexes of
|
||
|
-- certain subunits used as defaults during the printing process.
|
||
|
|
||
|
prtInputDefaultIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of prtInputIndex corresponding to the default input
|
||
|
sub-unit: that is, this object selects the default source of
|
||
|
input media."
|
||
|
::= { prtGeneralEntry 6 }
|
||
|
|
||
|
prtOutputDefaultIndex OBJECT-TYPE
|
||
|
-- A range has been added to the SYNTAX clause that was not in
|
||
|
-- RFC 1759. Although this violates SNMP compatibility rules,
|
||
|
-- it provides a more reasonable guide for SNMP managers.
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of prtOutputIndex corresponding to the default
|
||
|
output sub-unit; that is, this object selects the default
|
||
|
output destination."
|
||
|
::= { prtGeneralEntry 7 }
|
||
|
|
||
|
prtMarkerDefaultIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of prtMarkerIndex corresponding to the
|
||
|
default marker sub-unit; that is, this object selects the
|
||
|
default marker."
|
||
|
::= { prtGeneralEntry 8 }
|
||
|
|
||
|
prtMediaPathDefaultIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of prtMediaPathIndex corresponding to
|
||
|
the default media path; that is, the selection of the
|
||
|
default media path."
|
||
|
::= { prtGeneralEntry 9 }
|
||
|
|
||
|
-- Console general section
|
||
|
--
|
||
|
-- The following four objects describe overall parameters of the
|
||
|
-- printer console subsystem.
|
||
|
|
||
|
prtConsoleLocalization OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of the prtLocalizationIndex corresponding to
|
||
|
the language, country, and character set to be used for the
|
||
|
console. This localization applies both to the actual display
|
||
|
on the console as well as the encoding of these console objects
|
||
|
in management operations. When an object's 'charset' is
|
||
|
controlled by the value of prtConsoleLocalization, it MUST
|
||
|
specify PrtConsoleDescriptionStringTC as its syntax.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtGeneralEntry 10 }
|
||
|
|
||
|
prtConsoleNumberOfDisplayLines OBJECT-TYPE
|
||
|
SYNTAX Integer32 (0..65535)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of lines on the printer's physical
|
||
|
display. This value is 0 if there are no lines on the
|
||
|
physical display or if there is no physical display"
|
||
|
::= { prtGeneralEntry 11 }
|
||
|
|
||
|
prtConsoleNumberOfDisplayChars OBJECT-TYPE
|
||
|
SYNTAX Integer32 (0..65535)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of characters per line displayed on the physical
|
||
|
display. This value is 0 if there are no lines on the physical
|
||
|
display or if there is no physical display"
|
||
|
::= { prtGeneralEntry 12 }
|
||
|
|
||
|
prtConsoleDisable OBJECT-TYPE
|
||
|
-- In RFC 1759, the enumeration values were implicitly defined
|
||
|
-- by this object.
|
||
|
SYNTAX PrtConsoleDisableTC
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This value indicates how input is (or is not) accepted from
|
||
|
the operator console.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtGeneralEntry 13 }
|
||
|
|
||
|
-- The Auxiliary Sheet Group
|
||
|
--
|
||
|
-- The auxiliary sheet group allows the administrator to control
|
||
|
-- the production of auxiliary sheets by the printer. This group
|
||
|
-- contains only the "prtAuxiliarySheetStartupPage" and
|
||
|
-- "prtAuxiliarySheetBannerPage" objects.
|
||
|
|
||
|
prtAuxiliarySheetStartupPage OBJECT-TYPE
|
||
|
SYNTAX PresentOnOff
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used to enable or disable printing a startup page. If enabled,
|
||
|
a startup page will be printed shortly after power-up, when the
|
||
|
device is ready. Typical startup pages include test patterns
|
||
|
and/or printer configuration information."
|
||
|
::= { prtGeneralEntry 14 }
|
||
|
|
||
|
prtAuxiliarySheetBannerPage OBJECT-TYPE
|
||
|
SYNTAX PresentOnOff
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Used to enable or disable printing banner pages at the
|
||
|
beginning of jobs. This is a master switch which applies to all
|
||
|
jobs, regardless of interpreter."
|
||
|
::= { prtGeneralEntry 15 }
|
||
|
|
||
|
-- Administrative section (The General V2 Group)
|
||
|
--
|
||
|
-- The following two objects are used to specify administrative
|
||
|
-- information assigned to the printer.
|
||
|
|
||
|
prtGeneralPrinterName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (0..127))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An administrator-specified name for this printer. Depending
|
||
|
upon implementation of this printer, the value of this object
|
||
|
may or may not be same as the value for the MIB-II 'SysName'
|
||
|
object."
|
||
|
::= { prtGeneralEntry 16 }
|
||
|
|
||
|
prtGeneralSerialNumber OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (0..255))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A recorded serial number for this device that indexes some
|
||
|
type device catalog or inventory. This value is usually set by
|
||
|
the device manufacturer but the MIB supports the option of
|
||
|
writing for this object for site-specific administration of
|
||
|
device inventory or tracking."
|
||
|
::= { prtGeneralEntry 17 }
|
||
|
|
||
|
-- General alert table section (Alert Table V2 Group)
|
||
|
--
|
||
|
-- The following two objects are used to specify counters
|
||
|
-- associated with the Alert Table.
|
||
|
|
||
|
prtAlertCriticalEvents OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A running counter of the number of critical alert events that
|
||
|
have been recorded in the alert table. The value of this object
|
||
|
is RESET in the event of a power cycle operation (i.e., the
|
||
|
value is not persistent."
|
||
|
::= { prtGeneralEntry 18 }
|
||
|
|
||
|
prtAlertAllEvents OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A running counter of the total number of alert event entries
|
||
|
(critical and non-critical) that have been recorded in the
|
||
|
alert table"
|
||
|
::= { prtGeneralEntry 19 }
|
||
|
|
||
|
-- The Cover Table
|
||
|
--
|
||
|
-- The cover portion of the General print sub-unit describes the
|
||
|
-- covers and interlocks of the printer. The Cover Table has an
|
||
|
-- entry for each cover and interlock.
|
||
|
|
||
|
prtCover OBJECT IDENTIFIER ::= { printmib 6 }
|
||
|
|
||
|
prtCoverTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtCoverEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A table of the covers and interlocks of the printer."
|
||
|
::= { prtCover 1 }
|
||
|
|
||
|
prtCoverEntry OBJECT-TYPE
|
||
|
SYNTAX PrtCoverEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Information about a cover or interlock.
|
||
|
Entries may exist in the table for each device
|
||
|
index with a device type of 'printer'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtCoverIndex }
|
||
|
::= { prtCoverTable 1 }
|
||
|
|
||
|
PrtCoverEntry ::= SEQUENCE {
|
||
|
prtCoverIndex Integer32,
|
||
|
prtCoverDescription PrtLocalizedDescriptionStringTC,
|
||
|
prtCoverStatus PrtCoverStatusTC
|
||
|
}
|
||
|
|
||
|
prtCoverIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value used by the printer to identify this Cover sub
|
||
|
unit. Although these values may change due to a major
|
||
|
reconfiguration of the device (e.g., the addition of new cover
|
||
|
sub-units to the printer), values SHOULD remain stable across
|
||
|
successive printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtCoverEntry 1 }
|
||
|
|
||
|
prtCoverDescription OBJECT-TYPE
|
||
|
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
|
-- to a TC to better support localization of the object.
|
||
|
SYNTAX PrtLocalizedDescriptionStringTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The manufacturer provided cover sub-mechanism name in the
|
||
|
localization specified by prtGeneralCurrentLocalization."
|
||
|
::= { prtCoverEntry 2 }
|
||
|
|
||
|
prtCoverStatus OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly defined
|
||
|
-- by this object and are now defined in the IANA-PRINTER-MIB. The
|
||
|
-- new TC has defined "coverOpen" and "coverClosed" to replace
|
||
|
-- "doorOpen" and "doorClosed" in RFC 1759. A name change is not
|
||
|
-- formally allowed per SMI rules, but was agreed to by the WG group
|
||
|
-- since a door has a more restrictive meaning than a cover and
|
||
|
-- Cover group is intended to support doors as a subset of covers.
|
||
|
|
||
|
SYNTAX PrtCoverStatusTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The status of this cover sub-unit."
|
||
|
::= { prtCoverEntry 3 }
|
||
|
|
||
|
-- The Localization Table
|
||
|
--
|
||
|
-- The localization portion of the General printer sub-unit is
|
||
|
-- responsible for identifying the natural language, country, and
|
||
|
-- character set in which character strings are expressed. There
|
||
|
-- may be one or more localizations supported per printer. The
|
||
|
-- available localizations are represented by the Localization
|
||
|
-- table.
|
||
|
|
||
|
prtLocalization OBJECT IDENTIFIER ::= { printmib 7 }
|
||
|
|
||
|
prtLocalizationTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtLocalizationEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The available localizations in this printer."
|
||
|
::= { prtLocalization 1 }
|
||
|
|
||
|
prtLocalizationEntry OBJECT-TYPE
|
||
|
SYNTAX PrtLocalizationEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A description of a localization.
|
||
|
Entries may exist in the table for each device
|
||
|
index with a device type of 'printer'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtLocalizationIndex }
|
||
|
::= { prtLocalizationTable 1 }
|
||
|
|
||
|
PrtLocalizationEntry ::= SEQUENCE {
|
||
|
prtLocalizationIndex Integer32,
|
||
|
prtLocalizationLanguage OCTET STRING,
|
||
|
prtLocalizationCountry OCTET STRING,
|
||
|
prtLocalizationCharacterSet IANACharset
|
||
|
}
|
||
|
|
||
|
prtLocalizationIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value used by the printer to identify this
|
||
|
localization entry. Although these values may change due to a
|
||
|
major reconfiguration of the device (e.g., the addition of new
|
||
|
localization data to the printer), values SHOULD remain
|
||
|
stable across successive printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtLocalizationEntry 1 }
|
||
|
|
||
|
prtLocalizationLanguage OBJECT-TYPE
|
||
|
-- Note: The size is fixed, was incorrectly 0..2 in RFC 1759.
|
||
|
SYNTAX OCTET STRING (SIZE(2))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A two character language code from ISO 639. Examples en,
|
||
|
es, fr, de. NOTE: These examples were shown as upper case in
|
||
|
RFC 1759 and are now shown as lower case to agree with ISO 639."
|
||
|
::= { prtLocalizationEntry 2 }
|
||
|
|
||
|
prtLocalizationCountry OBJECT-TYPE
|
||
|
-- Note: The size is fixed, was incorrectly 0..2 in RFC 1759.
|
||
|
SYNTAX OCTET STRING (SIZE(2))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A two character country code from ISO 3166, a blank string
|
||
|
(two space characters) shall indicate that the country is not
|
||
|
defined. Examples: US, GB, FR, DE, ..."
|
||
|
::= { prtLocalizationEntry 3 }
|
||
|
|
||
|
prtLocalizationCharacterSet OBJECT-TYPE
|
||
|
SYNTAX IANACharset
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The coded character set used for this localization."
|
||
|
::= { prtLocalizationEntry 4 }
|
||
|
|
||
|
-- The System Resources Tables
|
||
|
--
|
||
|
-- The Printer MIB makes use of the Host Resources MIB to
|
||
|
-- define system resources by referencing the storage
|
||
|
-- and device groups of the print group.
|
||
|
|
||
|
prtStorageRefTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtStorageRefEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table defines which printer, amongst multiple printers
|
||
|
serviced by one agent, owns which storage units.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtGeneral 2 }
|
||
|
|
||
|
prtStorageRefEntry OBJECT-TYPE
|
||
|
SYNTAX PrtStorageRefEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table will have an entry for each entry in the Host
|
||
|
Resources MIB storage table that represents storage associated
|
||
|
with a printer managed by this agent.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrStorageIndex, prtStorageRefSeqNumber }
|
||
|
::= { prtStorageRefTable 1 }
|
||
|
|
||
|
PrtStorageRefEntry ::= SEQUENCE {
|
||
|
prtStorageRefSeqNumber Integer32,
|
||
|
prtStorageRefIndex Integer32
|
||
|
}
|
||
|
|
||
|
prtStorageRefSeqNumber OBJECT-TYPE
|
||
|
-- NOTE: The range has been changed from RFC 1759, which allowed a
|
||
|
-- minumum value of zero. This was incorrect, since zero is not a
|
||
|
-- valid index.
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This value will be unique amongst all entries with a common
|
||
|
value of hrStorageIndex. This object allows a storage entry to
|
||
|
point to the multiple printer devices with which it is
|
||
|
associated."
|
||
|
::= { prtStorageRefEntry 1 }
|
||
|
|
||
|
prtStorageRefIndex OBJECT-TYPE
|
||
|
-- NOTE: The range has been changed from RFC 1759 to be compatible
|
||
|
-- with the defined range of hrDeviceIndex.
|
||
|
SYNTAX Integer32 (0..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of the hrDeviceIndex of the printer device that this
|
||
|
storageEntry is associated with."
|
||
|
::= { prtStorageRefEntry 2 }
|
||
|
|
||
|
prtDeviceRefTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtDeviceRefEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table defines which printer, amongst multiple printers
|
||
|
serviced by one agent, is associated with which devices.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtGeneral 3 }
|
||
|
|
||
|
prtDeviceRefEntry OBJECT-TYPE
|
||
|
SYNTAX PrtDeviceRefEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table will have an entry for each entry in the Host
|
||
|
Resources MIB device table that represents a device associated
|
||
|
with a printer managed by this agent.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtDeviceRefSeqNumber }
|
||
|
::= { prtDeviceRefTable 1 }
|
||
|
|
||
|
PrtDeviceRefEntry ::= SEQUENCE {
|
||
|
prtDeviceRefSeqNumber Integer32,
|
||
|
prtDeviceRefIndex Integer32
|
||
|
}
|
||
|
|
||
|
prtDeviceRefSeqNumber OBJECT-TYPE
|
||
|
-- NOTE: The range has been changed from RFC 1759, which allowed a
|
||
|
-- minumum value of zero. This was incorrect, since zero is not a
|
||
|
-- valid index.
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This value will be unique amongst all entries with a common
|
||
|
value of hrDeviceIndex. This object allows a device entry to
|
||
|
point to the multiple printer devices with which it is
|
||
|
associated."
|
||
|
::= { prtDeviceRefEntry 1 }
|
||
|
|
||
|
prtDeviceRefIndex OBJECT-TYPE
|
||
|
-- NOTE: The range has been changed from RFC 1759 to be compatible
|
||
|
-- with the defined range of hrDeviceIndex.
|
||
|
SYNTAX Integer32 (0..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of the hrDeviceIndex of the printer device that this
|
||
|
deviceEntry is associated with."
|
||
|
::= { prtDeviceRefEntry 2 }
|
||
|
|
||
|
-- The Input Group
|
||
|
--
|
||
|
-- Input sub-units are managed as a tabular, indexed collection
|
||
|
-- of possible devices capable of providing media for input to
|
||
|
-- the printing process. Input sub-units typically have a
|
||
|
-- location, a type, an identifier, a set of constraints on
|
||
|
-- possible media sizes and potentially other media
|
||
|
-- characteristics, and may be capable of indicating current
|
||
|
-- status or capacity.
|
||
|
|
||
|
prtInput OBJECT IDENTIFIER ::= { printmib 8 }
|
||
|
|
||
|
prtInputTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtInputEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A table of the devices capable of providing media for input to
|
||
|
the printing process."
|
||
|
::= { prtInput 2 }
|
||
|
|
||
|
prtInputEntry OBJECT-TYPE
|
||
|
SYNTAX PrtInputEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Attributes of a device capable of providing media for input to
|
||
|
the printing process. Entries may exist in the table for each
|
||
|
device index with a device type of 'printer'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtInputIndex }
|
||
|
::= { prtInputTable 1 }
|
||
|
|
||
|
PrtInputEntry ::= SEQUENCE {
|
||
|
prtInputIndex Integer32,
|
||
|
prtInputType PrtInputTypeTC,
|
||
|
prtInputDimUnit PrtMediaUnitTC,
|
||
|
prtInputMediaDimFeedDirDeclared Integer32,
|
||
|
prtInputMediaDimXFeedDirDeclared Integer32,
|
||
|
prtInputMediaDimFeedDirChosen Integer32,
|
||
|
prtInputMediaDimXFeedDirChosen Integer32,
|
||
|
prtInputCapacityUnit PrtCapacityUnitTC,
|
||
|
prtInputMaxCapacity Integer32,
|
||
|
prtInputCurrentLevel Integer32,
|
||
|
prtInputStatus PrtSubUnitStatusTC,
|
||
|
prtInputMediaName OCTET STRING,
|
||
|
prtInputName OCTET STRING,
|
||
|
prtInputVendorName OCTET STRING,
|
||
|
prtInputModel OCTET STRING,
|
||
|
prtInputVersion OCTET STRING,
|
||
|
prtInputSerialNumber OCTET STRING,
|
||
|
prtInputDescription PrtLocalizedDescriptionStringTC,
|
||
|
prtInputSecurity PresentOnOff,
|
||
|
prtInputMediaWeight Integer32,
|
||
|
prtInputMediaType OCTET STRING,
|
||
|
prtInputMediaColor OCTET STRING,
|
||
|
prtInputMediaFormParts Integer32,
|
||
|
prtInputMediaLoadTimeout Integer32,
|
||
|
prtInputNextIndex Integer32
|
||
|
}
|
||
|
|
||
|
prtInputIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value used by the printer to identify this input
|
||
|
sub-unit. Although these values may change due to a major
|
||
|
reconfiguration of the device (e.g., the addition of new input
|
||
|
sub-units to the printer), values SHOULD remain stable across
|
||
|
successive printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtInputEntry 1 }
|
||
|
|
||
|
prtInputType OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtInputTypeTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The type of technology (discriminated primarily according to
|
||
|
feeder mechanism type) employed by the input sub-unit. Note,
|
||
|
the Input Class provides for a descriptor field to further
|
||
|
qualify the other choice."
|
||
|
::= { prtInputEntry 2 }
|
||
|
|
||
|
prtInputDimUnit OBJECT-TYPE
|
||
|
SYNTAX PrtMediaUnitTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The unit of measurement for use calculating and relaying
|
||
|
dimensional values for this input sub-unit."
|
||
|
::= { prtInputEntry 3 }
|
||
|
|
||
|
prtInputMediaDimFeedDirDeclared OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object provides the value of the declared dimension, in
|
||
|
the feed direction, of the media that is (or, if empty, was or
|
||
|
will be) in this input sub-unit. The feed direction is the
|
||
|
direction in which the media is fed on this sub-unit. This
|
||
|
dimension is measured in input sub-unit dimensional units
|
||
|
(controlled by prtInputDimUnit, which uses PrtMediaUnitTC). If
|
||
|
this input sub-unit can reliably sense this value, the value is
|
||
|
sensed by the printer and may not be changed by management
|
||
|
requests. Otherwise, the value may be changed. The value (-1)
|
||
|
means other and specifically means that this sub-unit places no
|
||
|
restriction on this parameter. The value (-2) indicates
|
||
|
unknown."
|
||
|
::= { prtInputEntry 4 }
|
||
|
|
||
|
prtInputMediaDimXFeedDirDeclared OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object provides the value of the declared dimension, in
|
||
|
the cross feed direction, of the media that is (or, if empty,
|
||
|
was or will be) in this input sub-unit. The cross feed
|
||
|
direction is ninety degrees relative to the feed direction
|
||
|
associated with this sub-unit. This dimension is measured in
|
||
|
input sub-unit dimensional units (controlled by
|
||
|
prtInputDimUnit,which uses PrtMediaUnitTC). If this input sub-
|
||
|
unit can reliably sense this value, the value is sensed by the
|
||
|
printer and may not be changed by management requests.
|
||
|
Otherwise, the value may be changed. The value (-1) means other
|
||
|
and specifically means that this sub-unit places no restriction
|
||
|
on this parameter. The value (-2) indicates unknown."
|
||
|
::= { prtInputEntry 5 }
|
||
|
|
||
|
prtInputMediaDimFeedDirChosen OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The printer will act as if media of the chosen dimension (in
|
||
|
the feed direction) is present in this input source. Note that
|
||
|
this value will be used even if the input tray is empty. Feed
|
||
|
dimension measurements are taken relative to the feed direction
|
||
|
associated with that sub-unit and are in input sub-unit
|
||
|
dimensional units (controlled by prtInputDimUnit, which uses
|
||
|
PrtMediaUnitTC). If the printer supports the declared
|
||
|
dimension,the granted dimension is the same as the declared
|
||
|
dimension. If not, the granted dimension is set to the closest
|
||
|
dimension that the printer supports when the declared dimension
|
||
|
is set. The value (-1) means other and specifically indicates
|
||
|
that this sub-unit places no restriction on this parameter. The
|
||
|
value (-2)indicates unknown."
|
||
|
::= { prtInputEntry 6 }
|
||
|
|
||
|
prtInputMediaDimXFeedDirChosen OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The printer will act as if media of the chosen dimension (in
|
||
|
the cross feed direction) is present in this input source. Note
|
||
|
that this value will be used even if the input tray is empty.
|
||
|
The cross feed direction is ninety degrees relative to the feed
|
||
|
direction associated with this sub-unit. This dimension is
|
||
|
measured in input sub-unit dimensional units (controlled by
|
||
|
prtInputDimUnit, which uses PrtMediaUnitTC). If the printer
|
||
|
supports the declare dimension, the granted dimension is the
|
||
|
same as the declared dimension. If not, the granted dimension
|
||
|
is set to the closest dimension that the printer supports when
|
||
|
the declared dimension is set. The value (-1) means other and
|
||
|
specifically indicates that this sub-unit places no restriction
|
||
|
on this parameter. The value (-2) indicates unknown."
|
||
|
::= { prtInputEntry 7 }
|
||
|
|
||
|
prtInputCapacityUnit OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtCapacityUnitTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The unit of measurement for use in calculating and relaying
|
||
|
capacity values for this input sub-unit."
|
||
|
::= { prtInputEntry 8 }
|
||
|
|
||
|
prtInputMaxCapacity OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum capacity of the input sub-unit in input sub-unit
|
||
|
capacity units (PrtCapacityUnitTC). There is no convention
|
||
|
associated with the media itself so this value reflects claimed
|
||
|
capacity. If this input sub-unit can reliably sense this value,
|
||
|
the value is sensed by the printer and may not be changed by
|
||
|
management requests; otherwise, the value may be written (by a
|
||
|
Remote Control Panel or a Management Application). The value
|
||
|
(-1) means other and specifically indicates that the sub-unit
|
||
|
places no restrictions on this parameter. The value (-2) means
|
||
|
unknown."
|
||
|
::= { prtInputEntry 9 }
|
||
|
|
||
|
prtInputCurrentLevel OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-3..2147483647) -- in capacity units
|
||
|
-- (PrtCapacityUnitTC).
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current capacity of the input sub-unit in input sub-unit
|
||
|
capacity units (PrtCapacityUnitTC). If this input sub-unit can
|
||
|
reliably sense this value, the value is sensed by the printer
|
||
|
and may not be changed by management requests; otherwise, the
|
||
|
value may be written (by a Remote Control Panel or a Management
|
||
|
Application). The value (-1) means other and specifically
|
||
|
indicates that the sub-unit places no restrictions on this
|
||
|
parameter. The value (-2) means unknown. The value (-3) means
|
||
|
that the printer knows that at least one unit remains."
|
||
|
::= { prtInputEntry 10 }
|
||
|
|
||
|
prtInputStatus OBJECT-TYPE
|
||
|
SYNTAX PrtSubUnitStatusTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current status of this input sub-unit."
|
||
|
::= { prtInputEntry 11 }
|
||
|
|
||
|
prtInputMediaName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A description of the media contained in this input sub-unit;
|
||
|
This description is to be used by a client to format and
|
||
|
Localize a string for display to a human operator. This
|
||
|
description is not processed by the printer. It is used to
|
||
|
provide information not expressible in terms of the other
|
||
|
media attributes (e.g., prtInputMediaDimFeedDirChosen,
|
||
|
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
|
||
|
prtInputMediaType)."
|
||
|
-- The following reference was not included in RFC 1759.
|
||
|
REFERENCE
|
||
|
"The PWG Standardized Media Names specification [PWGMEDIA]
|
||
|
contains the recommended values for this object. See also
|
||
|
RFC 3805 Appendix C,'Media Names', which lists the values
|
||
|
Of standardized media names defined in ISO/IEC 10175."
|
||
|
::= { prtInputEntry 12 }
|
||
|
|
||
|
-- INPUT MEASUREMENT
|
||
|
--
|
||
|
-- _______ | |
|
||
|
-- ^ | |
|
||
|
-- | | | |
|
||
|
-- | |_ _ _ _ _ _ _ _| _______________ |direction
|
||
|
-- | | | ^ v
|
||
|
-- MaxCapacity | Sheets | |
|
||
|
-- | | left | CurrentLevel
|
||
|
-- | | in | |
|
||
|
-- v | tray | v
|
||
|
-- _______ +_______________+ _______
|
||
|
|
||
|
-- The Extended Input Group
|
||
|
|
||
|
prtInputName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The name assigned to this input sub-unit."
|
||
|
::= { prtInputEntry 13 }
|
||
|
|
||
|
prtInputVendorName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The vendor name of this input sub-unit."
|
||
|
::= { prtInputEntry 14 }
|
||
|
|
||
|
prtInputModel OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The model name of this input sub-unit."
|
||
|
::= { prtInputEntry 15 }
|
||
|
|
||
|
prtInputVersion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The version of this input sub-unit."
|
||
|
::= { prtInputEntry 16 }
|
||
|
|
||
|
prtInputSerialNumber OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..32))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The serial number assigned to this input sub-unit."
|
||
|
::= { prtInputEntry 17 }
|
||
|
|
||
|
prtInputDescription OBJECT-TYPE
|
||
|
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
|
-- to a TC to better support localization of the object.
|
||
|
SYNTAX PrtLocalizedDescriptionStringTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A free-form text description of this input sub-unit in the
|
||
|
localization specified by prtGeneralCurrentLocalization."
|
||
|
::= { prtInputEntry 18 }
|
||
|
|
||
|
prtInputSecurity OBJECT-TYPE
|
||
|
SYNTAX PresentOnOff
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates if this input sub-unit has some security associated
|
||
|
with it."
|
||
|
::= { prtInputEntry 19 }
|
||
|
|
||
|
-- The Input Media Group
|
||
|
--
|
||
|
-- The Input Media Group supports identification of media
|
||
|
-- installed or available for use on a printing device.
|
||
|
-- Medium resources are identified by name, and include a
|
||
|
-- collection of characteristic attributes that may further be
|
||
|
-- used for selection and management of them.
|
||
|
-- The Input Media group consists of a set of optional
|
||
|
-- "columns" in the Input Table. In this manner, a minimally
|
||
|
-- conforming implementation may choose to not support reporting
|
||
|
-- of media resources if it cannot do so.
|
||
|
|
||
|
prtInputMediaWeight OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The weight of the medium associated with this input sub-unit
|
||
|
in grams / per meter squared. The value (-2) means unknown."
|
||
|
::= { prtInputEntry 20 }
|
||
|
|
||
|
prtInputMediaType OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The name of the type of medium associated with this input sub
|
||
|
unit. This name need not be processed by the printer; it might
|
||
|
simply be displayed to an operator.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759."
|
||
|
-- The following reference was not included in RFC 1759.
|
||
|
REFERENCE
|
||
|
"The PWG Standardized Media Names specification [PWGMEDIA],
|
||
|
section 3 Media Type Names, contains the recommended values for
|
||
|
this object. Implementers may add additional string values.
|
||
|
The naming conventions in ISO 9070 are recommended in order to
|
||
|
avoid potential name clashes."
|
||
|
::= { prtInputEntry 21 }
|
||
|
|
||
|
prtInputMediaColor OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The name of the color of the medium associated with
|
||
|
this input sub-unit using standardized string values.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759."
|
||
|
-- The following reference was not included in RFC 1759.
|
||
|
REFERENCE
|
||
|
"The PWG Standardized Media Names specification [PWGMEDIA],
|
||
|
section 4 Media Color Names, contains the recommended values
|
||
|
for this object. Implementers may add additional string values.
|
||
|
The naming conventions in ISO 9070 are recommended in order to
|
||
|
avoid potential name clashes."
|
||
|
::= { prtInputEntry 22 }
|
||
|
|
||
|
prtInputMediaFormParts OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of parts associated with the medium
|
||
|
associated with this input sub-unit if the medium is a
|
||
|
multi-part form. The value (-1) means other and
|
||
|
specifically indicates that the device places no
|
||
|
restrictions on this parameter. The value (-2) means
|
||
|
unknown."
|
||
|
::= { prtInputEntry 23 }
|
||
|
|
||
|
-- The Input Switching Group
|
||
|
--
|
||
|
-- The input switching group allows the administrator to set the
|
||
|
-- input subunit time-out for the printer and to control the
|
||
|
-- automatic input subunit switching by the printer when an input
|
||
|
-- subunit becomes empty.
|
||
|
|
||
|
prtInputMediaLoadTimeout OBJECT-TYPE
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"When the printer is not able to print due to a subunit being
|
||
|
empty or the requested media must be manually loaded, the
|
||
|
printer will wait for the duration (in seconds) specified by
|
||
|
this object. Upon expiration of the time-out, the printer will
|
||
|
take the action specified by prtInputNextIndex.
|
||
|
|
||
|
The event which causes the printer to enter the waiting state
|
||
|
is product specific. If the printer is not waiting for manually
|
||
|
fed media, it may switch from an empty subunit to a different
|
||
|
subunit without waiting for the time-out to expire.
|
||
|
|
||
|
A value of (-1) implies 'other' or 'infinite' which translates
|
||
|
to 'wait forever'. The action which causes printing to continue
|
||
|
is product specific. A value of (-2) implies 'unknown'."
|
||
|
::= { prtInputEntry 24 }
|
||
|
|
||
|
prtInputNextIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (-3..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of prtInputIndex corresponding to the input subunit
|
||
|
which will be used when this input subunit is emptied and the
|
||
|
time-out specified by prtInputMediaLoadTimeout expires. A value
|
||
|
of zero(0) indicates that auto input switching will not occur
|
||
|
when this input subunit is emptied. If the time-out specified
|
||
|
by prtInputLoadMediaTimeout expires and this value is zero(0),
|
||
|
the job will be aborted. A value of (-1) means other. The
|
||
|
value (-2)means 'unknown' and specifically indicates that an
|
||
|
implementation specific method will determine the next input
|
||
|
subunit to use at the time this subunit is emptied and the time
|
||
|
out expires. The value(-3) means input switching is not
|
||
|
supported for this subunit."
|
||
|
::= { prtInputEntry 25 }
|
||
|
|
||
|
-- The Output Group
|
||
|
--
|
||
|
-- Output sub-units are managed as a tabular, indexed collection
|
||
|
-- of possible devices capable of receiving media delivered from
|
||
|
-- the printing process. Output sub-units typically have a
|
||
|
-- location, a type, an identifier, a set of constraints on
|
||
|
-- possible media sizes and potentially other characteristics,
|
||
|
-- and may be capable of indicating current status or capacity.
|
||
|
|
||
|
prtOutput OBJECT IDENTIFIER ::= { printmib 9 }
|
||
|
|
||
|
prtOutputTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtOutputEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A table of the devices capable of receiving media delivered
|
||
|
from the printing process."
|
||
|
::= { prtOutput 2 }
|
||
|
|
||
|
prtOutputEntry OBJECT-TYPE
|
||
|
SYNTAX PrtOutputEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Attributes of a device capable of receiving media delivered
|
||
|
from the printing process. Entries may exist in the table for
|
||
|
each device index with a device type of 'printer'.
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtOutputIndex }
|
||
|
::= { prtOutputTable 1 }
|
||
|
|
||
|
PrtOutputEntry ::= SEQUENCE {
|
||
|
prtOutputIndex Integer32,
|
||
|
prtOutputType PrtOutputTypeTC,
|
||
|
prtOutputCapacityUnit PrtCapacityUnitTC,
|
||
|
prtOutputMaxCapacity Integer32,
|
||
|
prtOutputRemainingCapacity Integer32,
|
||
|
prtOutputStatus PrtSubUnitStatusTC,
|
||
|
prtOutputName OCTET STRING,
|
||
|
prtOutputVendorName OCTET STRING,
|
||
|
prtOutputModel OCTET STRING,
|
||
|
prtOutputVersion OCTET STRING,
|
||
|
prtOutputSerialNumber OCTET STRING,
|
||
|
prtOutputDescription PrtLocalizedDescriptionStringTC,
|
||
|
prtOutputSecurity PresentOnOff,
|
||
|
prtOutputDimUnit PrtMediaUnitTC,
|
||
|
prtOutputMaxDimFeedDir Integer32,
|
||
|
prtOutputMaxDimXFeedDir Integer32,
|
||
|
prtOutputMinDimFeedDir Integer32,
|
||
|
prtOutputMinDimXFeedDir Integer32,
|
||
|
prtOutputStackingOrder PrtOutputStackingOrderTC,
|
||
|
prtOutputPageDeliveryOrientation
|
||
|
PrtOutputPageDeliveryOrientationTC,
|
||
|
prtOutputBursting PresentOnOff,
|
||
|
prtOutputDecollating PresentOnOff,
|
||
|
prtOutputPageCollated PresentOnOff,
|
||
|
prtOutputOffsetStacking PresentOnOff
|
||
|
}
|
||
|
|
||
|
prtOutputIndex OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value used by this printer to identify this output
|
||
|
sub-unit. Although these values may change due to a major
|
||
|
reconfiguration of the sub-unit (e.g., the addition of new
|
||
|
output devices to the printer), values SHOULD remain stable
|
||
|
across successive printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtOutputEntry 1 }
|
||
|
|
||
|
prtOutputType OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly defined
|
||
|
-- by this object.
|
||
|
SYNTAX PrtOutputTypeTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The type of technology supported by this output sub-unit."
|
||
|
::= { prtOutputEntry 2 }
|
||
|
|
||
|
prtOutputCapacityUnit OBJECT-TYPE
|
||
|
SYNTAX PrtCapacityUnitTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The unit of measurement for use in calculating and relaying
|
||
|
capacity values for this output sub-unit."
|
||
|
::= { prtOutputEntry 3 }
|
||
|
|
||
|
prtOutputMaxCapacity OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum capacity of this output sub-unit in output sub-
|
||
|
unit capacity units (PrtCapacityUnitTC). There is no convention
|
||
|
associated with the media itself so this value essentially
|
||
|
reflects claimed capacity. If this output sub-unit can reliably
|
||
|
sense this value, the value is sensed by the printer and may
|
||
|
not be changed by management requests; otherwise, the value may
|
||
|
be written (by a Remote Control Panel or a Management
|
||
|
Application). The value (-1) means other and specifically
|
||
|
indicates that the sub-unit places no restrictions on this
|
||
|
parameter. The value (-2) means unknown."
|
||
|
::= { prtOutputEntry 4 }
|
||
|
|
||
|
prtOutputRemainingCapacity OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-3..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The remaining capacity of the possible output sub-unit
|
||
|
capacity in output sub-unit capacity units
|
||
|
(PrtCapacityUnitTC)of this output sub-unit. If this output sub-
|
||
|
unit can reliably sense this value, the value is sensed by the
|
||
|
printer and may not be modified by management requests;
|
||
|
otherwise, the value may be written (by a Remote Control Panel
|
||
|
or a Management Application). The value (-1) means other and
|
||
|
specifically indicates that the sub-unit places no restrictions
|
||
|
on this parameter. The value (-2) means unknown. The value
|
||
|
(-3) means that the printer knows that there remains capacity
|
||
|
for at least one unit."
|
||
|
::= { prtOutputEntry 5 }
|
||
|
|
||
|
prtOutputStatus OBJECT-TYPE
|
||
|
SYNTAX PrtSubUnitStatusTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current status of this output sub-unit."
|
||
|
::= { prtOutputEntry 6 }
|
||
|
|
||
|
-- OUTPUT MEASUREMENT
|
||
|
--
|
||
|
-- _______ | | ________
|
||
|
-- ^ | | ^
|
||
|
-- | | | |
|
||
|
-- | | |RemainingCapacity
|
||
|
-- MaxCapacity| | |
|
||
|
-- | | | v ^
|
||
|
-- | |_ _ _ _ _ _ _ _ | _______________ |direction
|
||
|
-- | | Sheets | |
|
||
|
-- | | in |
|
||
|
-- v | Output |
|
||
|
-- _______ +________________+
|
||
|
|
||
|
-- The Extended Output Group
|
||
|
|
||
|
prtOutputName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The name assigned to this output sub-unit."
|
||
|
::= { prtOutputEntry 7 }
|
||
|
|
||
|
prtOutputVendorName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The vendor name of this output sub-unit."
|
||
|
::= { prtOutputEntry 8 }
|
||
|
|
||
|
prtOutputModel OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The model name assigned to this output sub-unit.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtOutputEntry 9 }
|
||
|
|
||
|
prtOutputVersion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The version of this output sub-unit."
|
||
|
::= { prtOutputEntry 10 }
|
||
|
|
||
|
prtOutputSerialNumber OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The serial number assigned to this output sub-unit."
|
||
|
::= { prtOutputEntry 11 }
|
||
|
|
||
|
prtOutputDescription OBJECT-TYPE
|
||
|
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
|
-- to a TC to better support localization of the object.
|
||
|
SYNTAX PrtLocalizedDescriptionStringTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A free-form text description of this output sub-unit in the
|
||
|
localization specified by prtGeneralCurrentLocalization."
|
||
|
::= { prtOutputEntry 12 }
|
||
|
|
||
|
prtOutputSecurity OBJECT-TYPE
|
||
|
SYNTAX PresentOnOff
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates if this output sub-unit has some security associated
|
||
|
with it and if that security is enabled or not."
|
||
|
::= { prtOutputEntry 13 }
|
||
|
|
||
|
-- The Output Dimensions Group
|
||
|
|
||
|
prtOutputDimUnit OBJECT-TYPE
|
||
|
SYNTAX PrtMediaUnitTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The unit of measurement for use in calculating and relaying
|
||
|
dimensional values for this output sub-unit."
|
||
|
::= { prtOutputEntry 14 }
|
||
|
|
||
|
prtOutputMaxDimFeedDir OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum dimensions supported by this output sub-unit
|
||
|
for measurements taken parallel relative to the feed
|
||
|
direction associated with that sub-unit in output
|
||
|
sub-unit dimensional units (controlled by prtOutputDimUnit,
|
||
|
which uses PrtMediaUnitTC). If this output sub-unit can
|
||
|
reliably sense this value, the value is sensed by the printer
|
||
|
and may not be changed with management protocol operations.
|
||
|
The value (-1) means other and specifically indicates that the
|
||
|
sub-unit places no restrictions on this parameter. The value
|
||
|
(-2) means unknown.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification and to explain the purpose of (-1) and (-2)."
|
||
|
::= { prtOutputEntry 15 }
|
||
|
|
||
|
prtOutputMaxDimXFeedDir OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum dimensions supported by this output sub-unit
|
||
|
for measurements taken ninety degrees relative to the
|
||
|
feed direction associated with that sub-unit in output
|
||
|
sub-unit dimensional units (controlled by prtOutputDimUnit,
|
||
|
which uses PrtMediaUnitTC). If this output sub-unit can
|
||
|
reliably sense this value, the value is sensed by the printer
|
||
|
and may not be changed with management protocol operations.
|
||
|
The value (-1) means other and specifically indicates that the
|
||
|
sub-unit places no restrictions on this parameter. The value
|
||
|
(-2) means unknown.
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification and to explain the purpose of (-1) and (-2)."
|
||
|
::= { prtOutputEntry 16 }
|
||
|
|
||
|
prtOutputMinDimFeedDir OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The minimum dimensions supported by this output sub-unit
|
||
|
for measurements taken parallel relative to the feed
|
||
|
direction associated with that sub-unit in output
|
||
|
sub-unit dimensional units (controlled by prtOutputDimUnit,
|
||
|
which uses PrtMediaUnitTC). If this output sub-unit can
|
||
|
reliably sense this value, the value is sensed by the printer
|
||
|
and may not be changed with management protocol operations.
|
||
|
The value (-1) means other and specifically indicates that the
|
||
|
sub-unit places no restrictions on this parameter. The value
|
||
|
(-2) means unknown.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification and to explain the purpose of (-1) and (-2)."
|
||
|
::= { prtOutputEntry 17 }
|
||
|
|
||
|
prtOutputMinDimXFeedDir OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The minimum dimensions supported by this output sub-unit
|
||
|
for measurements taken ninety degrees relative to the
|
||
|
feed direction associated with that sub-unit in output
|
||
|
sub-unit dimensional units (controlled by prtOutputDimUnit,
|
||
|
which uses PrtMediaUnitTC). If this output sub-unit can
|
||
|
reliably sense this value, the value is sensed by the printer
|
||
|
and may not be changed with management protocol operations.
|
||
|
The value (-1) means other and specifically indicates that the
|
||
|
sub-unit places no restrictions on this parameter. The value
|
||
|
(-2) means unknown.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification and to explain the purpose of (-1) and (-2)."
|
||
|
::= { prtOutputEntry 18 }
|
||
|
|
||
|
-- The Output Features Group
|
||
|
|
||
|
prtOutputStackingOrder OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtOutputStackingOrderTC
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current state of the stacking order for the
|
||
|
associated output sub-unit. 'FirstToLast' means
|
||
|
that as pages are output the front of the next page is
|
||
|
placed against the back of the previous page.
|
||
|
'LasttoFirst' means that as pages are output the back
|
||
|
of the next page is placed against the front of the
|
||
|
previous page."
|
||
|
::= { prtOutputEntry 19 }
|
||
|
|
||
|
prtOutputPageDeliveryOrientation OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtOutputPageDeliveryOrientationTC
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The reading surface that will be 'up' when pages are
|
||
|
delivered to the associated output sub-unit. Values are
|
||
|
faceUp and faceDown. (Note: interpretation of these
|
||
|
values is in general context-dependent based on locale;
|
||
|
presentation of these values to an end-user should be
|
||
|
normalized to the expectations of the user)."
|
||
|
::= { prtOutputEntry 20 }
|
||
|
|
||
|
prtOutputBursting OBJECT-TYPE
|
||
|
SYNTAX PresentOnOff
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates that the outputting sub-unit supports
|
||
|
bursting, and if so, whether the feature is enabled. Bursting
|
||
|
is the process by which continuous media is separated into
|
||
|
individual sheets, typically by bursting along pre-formed
|
||
|
perforations."
|
||
|
::= { prtOutputEntry 21 }
|
||
|
|
||
|
prtOutputDecollating OBJECT-TYPE
|
||
|
SYNTAX PresentOnOff
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates that the output supports decollating,
|
||
|
and if so, whether the feature is enabled. Decollating is the
|
||
|
process by which the individual parts within a multi-part form
|
||
|
are separated and sorted into separate stacks for each part."
|
||
|
::= { prtOutputEntry 22 }
|
||
|
|
||
|
prtOutputPageCollated OBJECT-TYPE
|
||
|
SYNTAX PresentOnOff
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates that the output sub-unit supports page
|
||
|
collation, and if so, whether the feature is enabled. See RFC
|
||
|
3805 Appendix A, Glossary Of Terms, for definition of how this
|
||
|
document defines collation.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtOutputEntry 23 }
|
||
|
|
||
|
prtOutputOffsetStacking OBJECT-TYPE
|
||
|
SYNTAX PresentOnOff
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates that the output supports offset
|
||
|
stacking,and if so, whether the feature is enabled. See RFC
|
||
|
3805 Appendix A, Glossary Of Terms, for how Offset Stacking is
|
||
|
defined by this document.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtOutputEntry 24 }
|
||
|
|
||
|
-- The Marker Group
|
||
|
--
|
||
|
-- A marker is the mechanism that produces marks on the print
|
||
|
-- media. The marker sub-units and their associated supplies are
|
||
|
-- represented by the Marker Group in the model. A printer can
|
||
|
-- contain one or more marking mechanisms. Some examples of
|
||
|
-- multiple marker sub-units are: a printer
|
||
|
-- with separate markers for normal and magnetic ink or an
|
||
|
-- imagesetter that can output to both a proofing device and
|
||
|
-- final film. Each marking device can have its own set of
|
||
|
-- characteristics associated with it, such as marking technology
|
||
|
-- and resolution.
|
||
|
|
||
|
prtMarker OBJECT IDENTIFIER ::= { printmib 10 }
|
||
|
|
||
|
-- The printable area margins as listed below define an area of
|
||
|
-- the print media which is guaranteed to be printable for all
|
||
|
-- combinations of input, media paths, and interpreters for this
|
||
|
-- marker.
|
||
|
|
||
|
prtMarkerTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtMarkerEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The marker table provides a description of each marker
|
||
|
sub-unit contained within the printer.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarker 2 }
|
||
|
|
||
|
prtMarkerEntry OBJECT-TYPE
|
||
|
SYNTAX PrtMarkerEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Entries in this table define the characteristics and status
|
||
|
of each marker sub-unit in the printer.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtMarkerIndex }
|
||
|
::= { prtMarkerTable 1 }
|
||
|
|
||
|
PrtMarkerEntry ::= SEQUENCE {
|
||
|
prtMarkerIndex Integer32,
|
||
|
prtMarkerMarkTech PrtMarkerMarkTechTC,
|
||
|
prtMarkerCounterUnit PrtMarkerCounterUnitTC,
|
||
|
prtMarkerLifeCount Counter32,
|
||
|
prtMarkerPowerOnCount Counter32,
|
||
|
prtMarkerProcessColorants Integer32,
|
||
|
prtMarkerSpotColorants Integer32,
|
||
|
prtMarkerAddressabilityUnit PrtMarkerAddressabilityUnitTC,
|
||
|
prtMarkerAddressabilityFeedDir Integer32,
|
||
|
prtMarkerAddressabilityXFeedDir Integer32,
|
||
|
prtMarkerNorthMargin Integer32,
|
||
|
prtMarkerSouthMargin Integer32,
|
||
|
prtMarkerWestMargin Integer32,
|
||
|
prtMarkerEastMargin Integer32,
|
||
|
prtMarkerStatus PrtSubUnitStatusTC
|
||
|
}
|
||
|
|
||
|
prtMarkerIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value used by the printer to identify this marking
|
||
|
SubUnit. Although these values may change due to a major
|
||
|
reconfiguration of the device (e.g., the addition of new marking
|
||
|
sub-units to the printer), values SHOULD remain stable across
|
||
|
successive printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarkerEntry 1 }
|
||
|
|
||
|
prtMarkerMarkTech OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtMarkerMarkTechTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The type of marking technology used for this marking
|
||
|
sub-unit."
|
||
|
::= { prtMarkerEntry 2 }
|
||
|
|
||
|
prtMarkerCounterUnit OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtMarkerCounterUnitTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The unit that will be used by the printer when reporting
|
||
|
counter values for this marking sub-unit. The time units of
|
||
|
measure are provided for a device like a strip recorder that
|
||
|
does not or cannot track the physical dimensions of the media
|
||
|
and does not use characters, lines or sheets."
|
||
|
::= { prtMarkerEntry 3 }
|
||
|
|
||
|
prtMarkerLifeCount OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The count of the number of units of measure counted during the
|
||
|
life of printer using units of measure as specified by
|
||
|
prtMarkerCounterUnit.
|
||
|
|
||
|
Note: This object should be implemented as a persistent object
|
||
|
with a reliable value throughout the lifetime of the printer."
|
||
|
::= { prtMarkerEntry 4 }
|
||
|
|
||
|
prtMarkerPowerOnCount OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The count of the number of units of measure counted since the
|
||
|
equipment was most recently powered on using units of measure
|
||
|
as specified by prtMarkerCounterUnit."
|
||
|
::= { prtMarkerEntry 5 }
|
||
|
|
||
|
prtMarkerProcessColorants OBJECT-TYPE
|
||
|
SYNTAX Integer32 (0..65535)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of process colors supported by this marker. A
|
||
|
process color of 1 implies monochrome. The value of this
|
||
|
object and prtMarkerSpotColorants cannot both be 0. The value
|
||
|
of prtMarkerProcessColorants must be 0 or greater.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarkerEntry 6 }
|
||
|
|
||
|
prtMarkerSpotColorants OBJECT-TYPE
|
||
|
SYNTAX Integer32 (0..65535)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of spot colors supported by this marker. The value
|
||
|
of this object and prtMarkerProcessColorants cannot both be 0.
|
||
|
Must be 0 or greater.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarkerEntry 7 }
|
||
|
|
||
|
prtMarkerAddressabilityUnit OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtMarkerAddressabilityUnitTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The unit of measure of distances, as applied to the marker's
|
||
|
resolution.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarkerEntry 8 }
|
||
|
|
||
|
prtMarkerAddressabilityFeedDir OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum number of addressable marking positions in the
|
||
|
feed direction per 10000 units of measure specified by
|
||
|
prtMarkerAddressabilityUnit. A value of (-1) implies 'other'
|
||
|
or 'infinite' while a value of (-2) implies 'unknown'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarkerEntry 9 }
|
||
|
|
||
|
prtMarkerAddressabilityXFeedDir OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum number of addressable marking positions in the
|
||
|
cross feed direction in 10000 units of measure specified by
|
||
|
prtMarkerAddressabilityUnit. A value of (-1) implies 'other'
|
||
|
or 'infinite' while a value of (-2) implies 'unknown'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarkerEntry 10 }
|
||
|
|
||
|
prtMarkerNorthMargin OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The margin, in units identified by prtMarkerAddressabilityUnit,
|
||
|
from the leading edge of the medium as the medium flows through
|
||
|
the marking engine with the side to be imaged facing the
|
||
|
observer. The leading edge is the North edge and the other
|
||
|
edges are defined by the normal compass layout of directions
|
||
|
with the compass facing the observer. Printing within the area
|
||
|
bounded by all four margins is guaranteed for all interpreters.
|
||
|
The value (-2) means unknown."
|
||
|
::= { prtMarkerEntry 11 }
|
||
|
|
||
|
prtMarkerSouthMargin OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The margin from the South edge (see prtMarkerNorthMargin) of
|
||
|
the medium in units identified by prtMarkerAddressabilityUnit.
|
||
|
Printing within the area bounded by all four margins is
|
||
|
guaranteed for all interpreters. The value (-2) means unknown."
|
||
|
::= { prtMarkerEntry 12 }
|
||
|
|
||
|
prtMarkerWestMargin OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The margin from the West edge (see prtMarkerNorthMargin) of
|
||
|
the medium in units identified by prtMarkerAddressabilityUnit.
|
||
|
Printing within the area bounded by all four margins is
|
||
|
guaranteed for all interpreters. The value (-2) means unknown."
|
||
|
::= { prtMarkerEntry 13 }
|
||
|
|
||
|
prtMarkerEastMargin OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The margin from the East edge (see prtMarkerNorthMargin) of
|
||
|
the medium in units identified by prtMarkerAddressabilityUnit.
|
||
|
Printing within the area bounded by all four margins is
|
||
|
guaranteed for all interpreters. The value (-2) means unknown."
|
||
|
::= { prtMarkerEntry 14 }
|
||
|
|
||
|
prtMarkerStatus OBJECT-TYPE
|
||
|
SYNTAX PrtSubUnitStatusTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current status of this marker sub-unit."
|
||
|
::= { prtMarkerEntry 15 }
|
||
|
|
||
|
-- The Marker Supplies Group
|
||
|
|
||
|
prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }
|
||
|
|
||
|
prtMarkerSuppliesTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtMarkerSuppliesEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A table of the marker supplies available on this printer."
|
||
|
::= { prtMarkerSupplies 1 }
|
||
|
|
||
|
prtMarkerSuppliesEntry OBJECT-TYPE
|
||
|
SYNTAX PrtMarkerSuppliesEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Attributes of a marker supply. Entries may exist in the table
|
||
|
for each device index with a device type of 'printer'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtMarkerSuppliesIndex }
|
||
|
::= { prtMarkerSuppliesTable 1 }
|
||
|
PrtMarkerSuppliesEntry ::= SEQUENCE {
|
||
|
prtMarkerSuppliesIndex Integer32,
|
||
|
prtMarkerSuppliesMarkerIndex Integer32,
|
||
|
prtMarkerSuppliesColorantIndex Integer32,
|
||
|
prtMarkerSuppliesClass PrtMarkerSuppliesClassTC,
|
||
|
prtMarkerSuppliesType PrtMarkerSuppliesTypeTC,
|
||
|
prtMarkerSuppliesDescription PrtLocalizedDescriptionStringTC,
|
||
|
prtMarkerSuppliesSupplyUnit PrtMarkerSuppliesSupplyUnitTC,
|
||
|
prtMarkerSuppliesMaxCapacity Integer32,
|
||
|
prtMarkerSuppliesLevel Integer32
|
||
|
}
|
||
|
|
||
|
prtMarkerSuppliesIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value used by the printer to identify this marker
|
||
|
supply. Although these values may change due to a major
|
||
|
supplies to the printer), values SHOULD remain stable across
|
||
|
successive printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarkerSuppliesEntry 1 }
|
||
|
|
||
|
prtMarkerSuppliesMarkerIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (0..65535)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of prtMarkerIndex corresponding to the marking sub
|
||
|
unit with which this marker supply sub-unit is associated."
|
||
|
::= { prtMarkerSuppliesEntry 2 }
|
||
|
|
||
|
prtMarkerSuppliesColorantIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (0..65535)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of prtMarkerColorantIndex corresponding to the
|
||
|
colorant with which this marker supply sub-unit is associated.
|
||
|
This value shall be 0 if there is no colorant table or if this
|
||
|
supply does not depend on a single specified colorant.
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarkerSuppliesEntry 3 }
|
||
|
|
||
|
prtMarkerSuppliesClass OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtMarkerSuppliesClassTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates whether this supply entity represents a supply that
|
||
|
is consumed or a receptacle that is filled.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarkerSuppliesEntry 4 }
|
||
|
|
||
|
prtMarkerSuppliesType OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtMarkerSuppliesTypeTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The type of this supply."
|
||
|
::= { prtMarkerSuppliesEntry 5 }
|
||
|
|
||
|
prtMarkerSuppliesDescription OBJECT-TYPE
|
||
|
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
|
-- to a TC to better support localization of the object.
|
||
|
SYNTAX PrtLocalizedDescriptionStringTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The description of this supply container/receptacle in the
|
||
|
localization specified by prtGeneralCurrentLocalization."
|
||
|
::= { prtMarkerSuppliesEntry 6 }
|
||
|
|
||
|
prtMarkerSuppliesSupplyUnit OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtMarkerSuppliesSupplyUnitTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Unit of measure of this marker supply container/receptacle.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarkerSuppliesEntry 7 }
|
||
|
|
||
|
prtMarkerSuppliesMaxCapacity OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum capacity of this supply container/receptacle
|
||
|
expressed in prtMarkerSuppliesSupplyUnit. If this supply
|
||
|
container/receptacle can reliably sense this value, the value
|
||
|
is reported by the printer and is read-only; otherwise, the
|
||
|
value may be written (by a Remote Control Panel or a Management
|
||
|
Application). The value (-1) means other and specifically
|
||
|
indicates that the sub-unit places no restrictions on this
|
||
|
parameter. The value (-2) means unknown."
|
||
|
::= { prtMarkerSuppliesEntry 8 }
|
||
|
|
||
|
prtMarkerSuppliesLevel OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-3..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current level if this supply is a container; the remaining
|
||
|
space if this supply is a receptacle. If this supply
|
||
|
container/receptacle can reliably sense this value, the value
|
||
|
is reported by the printer and is read-only; otherwise, the
|
||
|
value may be written (by a Remote Control Panel or a Management
|
||
|
Application). The value (-1) means other and specifically
|
||
|
indicates that the sub-unit places no restrictions on this
|
||
|
parameter. The value (-2) means unknown. A value of (-3) means
|
||
|
that the printer knows that there is some supply/remaining
|
||
|
space, respectively."
|
||
|
::= { prtMarkerSuppliesEntry 9 }
|
||
|
|
||
|
-- The Marker Colorant Group
|
||
|
|
||
|
prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 }
|
||
|
|
||
|
prtMarkerColorantTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtMarkerColorantEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A table of all of the colorants available on the printer."
|
||
|
::= { prtMarkerColorant 1 }
|
||
|
|
||
|
prtMarkerColorantEntry OBJECT-TYPE
|
||
|
SYNTAX PrtMarkerColorantEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Attributes of a colorant available on the printer. Entries may
|
||
|
exist in the table for each device index with a device type of
|
||
|
'printer'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtMarkerColorantIndex }
|
||
|
::= { prtMarkerColorantTable 1 }
|
||
|
|
||
|
PrtMarkerColorantEntry ::= SEQUENCE {
|
||
|
prtMarkerColorantIndex Integer32,
|
||
|
prtMarkerColorantMarkerIndex Integer32,
|
||
|
prtMarkerColorantRole PrtMarkerColorantRoleTC,
|
||
|
prtMarkerColorantValue OCTET STRING,
|
||
|
prtMarkerColorantTonality Integer32
|
||
|
}
|
||
|
|
||
|
prtMarkerColorantIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value used by the printer to identify this colorant.
|
||
|
Although these values may change due to a major reconfiguration
|
||
|
of the device (e.g., the addition of new colorants to the
|
||
|
printer) , values SHOULD remain stable across successive
|
||
|
printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMarkerColorantEntry 1 }
|
||
|
|
||
|
prtMarkerColorantMarkerIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (0..65535)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of prtMarkerIndex corresponding to the marker sub
|
||
|
unit with which this colorant entry is associated."
|
||
|
::= { prtMarkerColorantEntry 2 }
|
||
|
|
||
|
prtMarkerColorantRole OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtMarkerColorantRoleTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The role played by this colorant."
|
||
|
::= { prtMarkerColorantEntry 3 }
|
||
|
|
||
|
prtMarkerColorantValue OBJECT-TYPE
|
||
|
-- NOTE: The string length range has been increased from RFC 1759.
|
||
|
SYNTAX OCTET STRING (SIZE(0..255))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The name of the color of this colorant using standardized
|
||
|
string names from ISO 10175 (DPA) and ISO 10180 (SPDL) such as:
|
||
|
other
|
||
|
unknown
|
||
|
white
|
||
|
red
|
||
|
green
|
||
|
blue
|
||
|
cyan
|
||
|
magenta
|
||
|
yellow
|
||
|
black
|
||
|
Implementers may add additional string values. The naming
|
||
|
conventions in ISO 9070 are recommended in order to avoid
|
||
|
potential name clashes"
|
||
|
::= { prtMarkerColorantEntry 4 }
|
||
|
|
||
|
prtMarkerColorantTonality OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The distinct levels of tonality realizable by a marking sub
|
||
|
unit when using this colorant. This value does not include the
|
||
|
number of levels of tonal difference that an interpreter can
|
||
|
obtain by techniques such as half toning. This value must be at
|
||
|
least 2."
|
||
|
::= { prtMarkerColorantEntry 5 }
|
||
|
|
||
|
-- The Media Path Group
|
||
|
--
|
||
|
-- The media paths encompass the mechanisms in the printer that
|
||
|
-- move the media through the printer and connect all other media
|
||
|
-- related sub-units: inputs, outputs, markers and finishers. A
|
||
|
-- printer contains one or more media paths. These are
|
||
|
-- represented by the Media Path Group in the model.
|
||
|
|
||
|
prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }
|
||
|
|
||
|
prtMediaPathTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtMediaPathEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The media path table includes both physical and logical paths
|
||
|
within the printer.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMediaPath 4 }
|
||
|
|
||
|
prtMediaPathEntry OBJECT-TYPE
|
||
|
SYNTAX PrtMediaPathEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Entries may exist in the table for each device index with a
|
||
|
device type of 'printer' Each entry defines the physical
|
||
|
characteristics of and the status of the media path. The data
|
||
|
provided indicates the maximum throughput and the media
|
||
|
size limitations of these subunits.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtMediaPathIndex }
|
||
|
::= { prtMediaPathTable 1 }
|
||
|
|
||
|
PrtMediaPathEntry ::= SEQUENCE {
|
||
|
prtMediaPathIndex Integer32,
|
||
|
prtMediaPathMaxSpeedPrintUnit PrtMediaPathMaxSpeedPrintUnitTC,
|
||
|
prtMediaPathMediaSizeUnit PrtMediaUnitTC,
|
||
|
prtMediaPathMaxSpeed Integer32,
|
||
|
prtMediaPathMaxMediaFeedDir Integer32,
|
||
|
prtMediaPathMaxMediaXFeedDir Integer32,
|
||
|
prtMediaPathMinMediaFeedDir Integer32,
|
||
|
prtMediaPathMinMediaXFeedDir Integer32,
|
||
|
prtMediaPathType PrtMediaPathTypeTC,
|
||
|
prtMediaPathDescription PrtLocalizedDescriptionStringTC,
|
||
|
prtMediaPathStatus PrtSubUnitStatusTC
|
||
|
}
|
||
|
|
||
|
prtMediaPathIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value used by the printer to identify this media
|
||
|
path. Although these values may change due to a major
|
||
|
reconfiguration of the device (e.g., the addition of new media
|
||
|
paths to the printer), values SHOULD remain stable across
|
||
|
successive printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMediaPathEntry 1 }
|
||
|
|
||
|
prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtMediaPathMaxSpeedPrintUnitTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The unit of measure used in specifying the speed of all media
|
||
|
paths in the printer."
|
||
|
::= { prtMediaPathEntry 2 }
|
||
|
|
||
|
prtMediaPathMediaSizeUnit OBJECT-TYPE
|
||
|
SYNTAX PrtMediaUnitTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The units of measure of media size for use in calculating and
|
||
|
relaying dimensional values for all media paths in the
|
||
|
printer."
|
||
|
::= { prtMediaPathEntry 3 }
|
||
|
|
||
|
prtMediaPathMaxSpeed OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum printing speed of this media path expressed in
|
||
|
prtMediaPathMaxSpeedUnit's. A value of (-1) implies 'other'."
|
||
|
::= { prtMediaPathEntry 4 }
|
||
|
|
||
|
prtMediaPathMaxMediaFeedDir OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum physical media size in the feed direction of this
|
||
|
media path expressed in units of measure specified by
|
||
|
PrtMediaPathMediaSizeUnit. A value of (-1) implies 'unlimited'
|
||
|
a value of (-2) implies 'unknown'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMediaPathEntry 5 }
|
||
|
|
||
|
prtMediaPathMaxMediaXFeedDir OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum physical media size across the feed direction of
|
||
|
this media path expressed in units of measure specified by
|
||
|
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMediaPathEntry 6 }
|
||
|
|
||
|
prtMediaPathMinMediaFeedDir OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The minimum physical media size in the feed direction of this
|
||
|
media path expressed in units of measure specified by
|
||
|
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMediaPathEntry 7 }
|
||
|
|
||
|
prtMediaPathMinMediaXFeedDir OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The minimum physical media size across the feed direction of
|
||
|
this media path expressed in units of measure specified by
|
||
|
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtMediaPathEntry 8 }
|
||
|
|
||
|
prtMediaPathType OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtMediaPathTypeTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The type of the media path for this media path."
|
||
|
::= { prtMediaPathEntry 9 }
|
||
|
|
||
|
prtMediaPathDescription OBJECT-TYPE
|
||
|
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
|
-- to a TC to better support localization of the object.
|
||
|
SYNTAX PrtLocalizedDescriptionStringTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The manufacturer-provided description of this media path in
|
||
|
the localization specified by prtGeneralCurrentLocalization."
|
||
|
::= { prtMediaPathEntry 10 }
|
||
|
|
||
|
prtMediaPathStatus OBJECT-TYPE
|
||
|
SYNTAX PrtSubUnitStatusTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current status of this media path."
|
||
|
::= { prtMediaPathEntry 11 }
|
||
|
|
||
|
-- The Print Job Delivery Channel Group
|
||
|
--
|
||
|
-- Print Job Delivery Channels are independent sources of print
|
||
|
-- data. Here, print data is the term used for the information
|
||
|
-- that is used to construct printed pages and may have both data
|
||
|
-- and control aspects. The output of a channel is in a form
|
||
|
-- suitable for input to one of the interpreters as a
|
||
|
-- stream. A channel may be independently enabled (allowing
|
||
|
-- print data to flow) or disabled (stopping the flow of
|
||
|
-- print data). A printer may have one or more channels.
|
||
|
--
|
||
|
-- The Print Job Delivery Channel table describes the
|
||
|
-- capabilities of the printer and not what is currently being
|
||
|
-- performed by the printer
|
||
|
--
|
||
|
-- Basically, the print job delivery channel abstraction
|
||
|
-- describes the final processing step of getting the print data
|
||
|
-- to an interpreter. It might include some level of
|
||
|
-- decompression or decoding of print stream data.
|
||
|
-- channel. All of these aspects are hidden in the channel
|
||
|
-- abstraction.
|
||
|
--
|
||
|
-- There are many kinds of print job delivery channels; some of
|
||
|
-- which are based on networks and others which are not. For
|
||
|
-- example, a channel can be a serial (or parallel) connection;
|
||
|
-- it can be a service, such as the UNIX Line Printer Daemon
|
||
|
-- (LPD), offering services over a network connection; or
|
||
|
-- it could be a disk drive into which a floppy disk with
|
||
|
-- the print data is inserted. Each print job delivery channel is
|
||
|
-- identified by the electronic path and/or service protocol
|
||
|
-- used to deliver print data to a print data interpreter.
|
||
|
--
|
||
|
-- Channel example Implementation
|
||
|
--
|
||
|
-- serial port channel bi-directional data channel
|
||
|
-- parallel port channel often uni-directional channel
|
||
|
-- IEEE 1284 port channel bi-directional channel
|
||
|
-- SCSI port channel bi-directional
|
||
|
-- Apple PAP channel may be based on LocalTalk,
|
||
|
-- Ethernet or Tokentalk
|
||
|
-- LPD Server channel TCP/IP based, port 515
|
||
|
-- Netware Remote Printer SPX/IPX based channel
|
||
|
-- Netware Print Server SPX/IPX based channel
|
||
|
--
|
||
|
-- It is easy to note that this is a mixed bag. There are
|
||
|
-- some physical connections over which no (or very meager)
|
||
|
-- protocols are run (e.g., the serial or old parallel ports)
|
||
|
-- and there are services which often have elaborate
|
||
|
-- protocols that run over a number of protocol stacks. In
|
||
|
-- the end, what is important is the delivery of print data
|
||
|
-- through the channel.
|
||
|
--
|
||
|
-- The print job delivery channel sub-units are represented by
|
||
|
-- the Print Job Delivery Channel Group in the Model. It has a
|
||
|
-- current print job control language, which can be used to
|
||
|
-- specify which interpreter is to be used for the print data and
|
||
|
-- to query and change environment variables used by the
|
||
|
-- interpreters (and Management Applications). There is also a
|
||
|
-- default interpreter that is to be used if an interpreter is
|
||
|
-- not explicitly specified using the Control Language.
|
||
|
|
||
|
-- The first seven items in the Print Job Delivery Channel Table
|
||
|
-- define the "channel" itself. A channel typically depends on
|
||
|
-- other protocols and interfaces to provide the data that flows
|
||
|
-- through the channel.
|
||
|
--
|
||
|
-- Control of a print job delivery channel is largely limited to
|
||
|
-- enabling or disabling the entire channel itself. It is likely
|
||
|
-- that more control of the process of accessing print data
|
||
|
-- will be needed over time. Thus, the ChannelType will
|
||
|
-- allow type-specific data to be associated with each
|
||
|
-- channel (using ChannelType specific groups in a fashion
|
||
|
-- analogous to the media specific MIBs that are associated
|
||
|
-- with the IANAIfType in the Interfaces Table). As a first
|
||
|
-- step in this direction, each channel will identify the
|
||
|
-- underlying Interface on which it is based. This is the
|
||
|
-- eighth object in each row of the table.
|
||
|
|
||
|
-- The Print Job Delivery Channel Table
|
||
|
|
||
|
prtChannel OBJECT IDENTIFIER ::= { printmib 14 }
|
||
|
|
||
|
prtChannelTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtChannelEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The channel table represents the set of input data sources
|
||
|
which can provide print data to one or more of the
|
||
|
interpreters available on a printer.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtChannel 1 }
|
||
|
|
||
|
prtChannelEntry OBJECT-TYPE
|
||
|
SYNTAX PrtChannelEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Entries may exist in the table for each device index with a
|
||
|
device type of 'printer'. Each channel table entry is
|
||
|
characterized by a unique protocol stack and/or addressing.
|
||
|
The channel may also have printer dependent features that are
|
||
|
associated with a printing language.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtChannelIndex }
|
||
|
::= { prtChannelTable 1 }
|
||
|
|
||
|
PrtChannelEntry ::= SEQUENCE {
|
||
|
prtChannelIndex Integer32,
|
||
|
prtChannelType PrtChannelTypeTC,
|
||
|
prtChannelProtocolVersion OCTET STRING,
|
||
|
prtChannelCurrentJobCntlLangIndex Integer32,
|
||
|
prtChannelDefaultPageDescLangIndex Integer32,
|
||
|
prtChannelState PrtChannelStateTC,
|
||
|
prtChannelIfIndex InterfaceIndexOrZero,
|
||
|
prtChannelStatus PrtSubUnitStatusTC,
|
||
|
prtChannelInformation OCTET STRING
|
||
|
}
|
||
|
|
||
|
prtChannelIndex OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value used by the printer to identify this data
|
||
|
channel. Although these values may change due to a major
|
||
|
reconfiguration of the device (e.g., the addition of new data
|
||
|
channels to the printer), values SHOULD remain stable across
|
||
|
successive printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtChannelEntry 1 }
|
||
|
|
||
|
prtChannelType OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtChannelTypeTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The type of this print data channel. This object provides the
|
||
|
linkage to ChannelType-specific groups that may (conceptually)
|
||
|
extend the prtChannelTable with additional details about that
|
||
|
channel."
|
||
|
::= { prtChannelEntry 2 }
|
||
|
|
||
|
prtChannelProtocolVersion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..63))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The version of the protocol used on this channel. The format
|
||
|
used for version numbering depends on prtChannelType."
|
||
|
::= { prtChannelEntry 3 }
|
||
|
|
||
|
prtChannelCurrentJobCntlLangIndex OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (0..65535)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of prtInterpreterIndex corresponding to the Control
|
||
|
Language Interpreter for this channel. This interpreter defines
|
||
|
the syntax used for control functions, such as querying or
|
||
|
changing environment variables and identifying job boundaries
|
||
|
(e.g., PJL, PostScript, NPAP). A value of zero indicates that
|
||
|
there is no current Job Control Language Interpreter for this
|
||
|
channel.
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtChannelEntry 4 }
|
||
|
|
||
|
prtChannelDefaultPageDescLangIndex OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (0..65535)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of prtInterpreterIndex corresponding to the Page
|
||
|
Description Language Interpreter for this channel. This
|
||
|
interpreter defines the default Page Description Language
|
||
|
interpreter to be used for the print data unless the Control
|
||
|
Language is used to select a specific interpreter (e.g., PCL,
|
||
|
PostScript Language, auto-sense). A value of zero indicates
|
||
|
that there is no default page description language interpreter
|
||
|
for this channel.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtChannelEntry 5 }
|
||
|
|
||
|
prtChannelState OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtChannelStateTC
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The state of this print data channel. The value determines
|
||
|
whether control information and print data is allowed through
|
||
|
this channel or not."
|
||
|
::= { prtChannelEntry 6 }
|
||
|
|
||
|
prtChannelIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndexOrZero -- Was Integer32 in RFC 1759.
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of ifIndex in the ifTable; see the Interfaces Group
|
||
|
MIB [RFC2863] which corresponds to this channel.
|
||
|
When more than one row of the ifTable is relevant, this is the
|
||
|
index of the row representing the topmost layer in the
|
||
|
interface hierarchy. A value of zero indicates that no
|
||
|
interface is associated with this channel.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtChannelEntry 7 }
|
||
|
|
||
|
prtChannelStatus OBJECT-TYPE
|
||
|
SYNTAX PrtSubUnitStatusTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current status of the channel."
|
||
|
::= { prtChannelEntry 8 }
|
||
|
|
||
|
prtChannelInformation OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (0..255))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Auxiliary information to allow a printing application to use
|
||
|
the channel for data submission to the printer. An application
|
||
|
capable of using a specific PrtChannelType should be able to
|
||
|
use the combined information from the prtChannelInformation and
|
||
|
other channel and interface group objects to 'bootstrap' its
|
||
|
use of the channel. prtChannelInformation is not intended to
|
||
|
provide a general channel description, nor to provide
|
||
|
information that is available once the channel is in use.
|
||
|
|
||
|
The encoding and interpretation of the prtChannelInformation
|
||
|
object is specific to channel type. The description of each
|
||
|
PrtChannelType enum value for which prtChannelInformation is
|
||
|
defined specifies the appropriate encoding and interpretation,
|
||
|
including interaction with other objects. For channel types
|
||
|
that do not specify a prtChannelInformation value, its value
|
||
|
shall be null (0 length).
|
||
|
|
||
|
When a new PrtChannelType enumeration value is registered, its
|
||
|
accompanying description must specify the encoding and
|
||
|
interpretation of the prtChannelInformation value for the
|
||
|
channel type. prtChannelInformation semantics for an existing
|
||
|
PrtChannelType may be added or amended in the same manner as
|
||
|
described in section 2.4.1 for type 2 enumeration values.
|
||
|
|
||
|
The prtChannelInformation specifies values for a collection of
|
||
|
channel attributes, represented as text according to the
|
||
|
following rules:
|
||
|
|
||
|
1. The prtChannelInformation is not affected by localization.
|
||
|
|
||
|
2. The prtChannelInformation is a list of entries representing
|
||
|
items, in order:
|
||
|
|
||
|
a. A keyword, composed of alphabetic characters (A-Z, a-z)
|
||
|
represented by their NVT ASCII [RFC854] codes, that
|
||
|
identifies a channel attribute,
|
||
|
|
||
|
b. The NVT ASCII code for an Equals Sign (=) (code 61) to
|
||
|
delimit the keyword,
|
||
|
|
||
|
c. A data value encoded using rules specific to the
|
||
|
PrtChannelType to with the prtChannelInformation applies which
|
||
|
must in no case allow an octet with value 10 (the NVT ASCII
|
||
|
Line Feed code),
|
||
|
|
||
|
d. the NVT ASCII code for a Line Feed character (code 10) to
|
||
|
delimit the data value.
|
||
|
|
||
|
No other octets shall be present.
|
||
|
|
||
|
Keywords are case-sensitive. Conventionally, keywords are
|
||
|
capitalized (including each word of a multi-word keyword) and
|
||
|
since they occupy space in the prtChannelInformation, they are
|
||
|
kept short.
|
||
|
|
||
|
3. If a channel attribute has multiple values, it is
|
||
|
represented by multiple entries with the same keyword, each
|
||
|
specifying one value. Otherwise, there shall be at most one
|
||
|
entry for each attribute.
|
||
|
|
||
|
4. By default, entries may appear in any order. If there are
|
||
|
ordering constraints for particular entries, these must be
|
||
|
specified in their definitions.
|
||
|
|
||
|
5. The prtChannelInformation value by default consists of text
|
||
|
represented by NVT ASCII graphics character codes. However,
|
||
|
other representations may be specified:
|
||
|
|
||
|
a. In cases where the prtChannelInformation value contains
|
||
|
information not normally coded in textual form, whatever
|
||
|
symbolic representation is conventionally used for the
|
||
|
information should be used for encoding the
|
||
|
prtChannelInformation value. (For instance, a binary port value
|
||
|
might be represented as a decimal number using NVT ASCII
|
||
|
codes.) Such encoding must be specified in the definition of
|
||
|
the value.
|
||
|
|
||
|
b. The value may contain textual information in a character set
|
||
|
other than NVT ASCII graphics characters. (For instance, an
|
||
|
identifier might consist of ISO 10646 text encoded using the
|
||
|
UTF-8 encoding scheme.) Such a character set and its encoding
|
||
|
must be specified in the definition of the value.
|
||
|
|
||
|
6. For each PrtChannelType for which prtChannelInformation
|
||
|
entries are defined, the descriptive text associated with the
|
||
|
PrtChannelType enumeration value shall specify the following
|
||
|
information for each entry:
|
||
|
|
||
|
Title: Brief description phrase, e.g.: 'Port name',
|
||
|
'Service Name', etc.
|
||
|
|
||
|
Keyword: The keyword value, e.g.: 'Port' or 'Service'
|
||
|
|
||
|
Syntax: The encoding of the entry value if it cannot be
|
||
|
directly represented by NVT ASCII.
|
||
|
|
||
|
Status: 'Mandatory', 'Optional', or 'Conditionally
|
||
|
Mandatory'
|
||
|
|
||
|
Multiplicity: 'Single' or 'Multiple' to indicate whether the
|
||
|
entry may be present multiple times.
|
||
|
|
||
|
Description: Description of the use of the entry, other
|
||
|
information required to complete the definition
|
||
|
(e.g.: ordering constraints, interactions between
|
||
|
entries).
|
||
|
|
||
|
Applications that interpret prtChannelInformation should ignore
|
||
|
unrecognized entries, so they are not affected if new entry
|
||
|
types are added."
|
||
|
|
||
|
::= { prtChannelEntry 9 }
|
||
|
|
||
|
-- The Interpreter Group
|
||
|
--
|
||
|
-- The interpreter sub-units are responsible for the conversion
|
||
|
-- of a description of intended print instances into images that
|
||
|
-- are to be marked on the media. A printer may have one or more
|
||
|
-- interpreters. The interpreter sub-units are represented by the
|
||
|
-- Interpreter Group in the Model. Each interpreter is generally
|
||
|
-- implemented with software running on the System Controller
|
||
|
-- sub-unit. The Interpreter Table has one entry per interpreter
|
||
|
-- where the interpreters include both Page Description Language
|
||
|
-- (PDL) Interpreters and Control Language Interpreters.
|
||
|
|
||
|
prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }
|
||
|
|
||
|
-- Interpreter Table
|
||
|
|
||
|
prtInterpreterTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtInterpreterEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The interpreter table is a table representing the
|
||
|
interpreters in the printer. An entry shall be placed in the
|
||
|
interpreter table for each interpreter on the printer.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtInterpreter 1 }
|
||
|
|
||
|
prtInterpreterEntry OBJECT-TYPE
|
||
|
SYNTAX PrtInterpreterEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Entries may exist in the table for each device index with a
|
||
|
device type of 'printer'. Each table entry provides a complete
|
||
|
description of the interpreter, including version information,
|
||
|
rendering resolutions, default character sets, output
|
||
|
orientation, and communication capabilities.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtInterpreterIndex }
|
||
|
::= { prtInterpreterTable 1 }
|
||
|
|
||
|
PrtInterpreterEntry ::= SEQUENCE {
|
||
|
prtInterpreterIndex Integer32,
|
||
|
prtInterpreterLangFamily PrtInterpreterLangFamilyTC,
|
||
|
prtInterpreterLangLevel OCTET STRING,
|
||
|
prtInterpreterLangVersion OCTET STRING,
|
||
|
prtInterpreterDescription PrtLocalizedDescriptionStringTC,
|
||
|
prtInterpreterVersion OCTET STRING,
|
||
|
prtInterpreterDefaultOrientation PrtPrintOrientationTC,
|
||
|
prtInterpreterFeedAddressability Integer32,
|
||
|
prtInterpreterXFeedAddressability Integer32,
|
||
|
prtInterpreterDefaultCharSetIn IANACharset,
|
||
|
prtInterpreterDefaultCharSetOut IANACharset,
|
||
|
prtInterpreterTwoWay PrtInterpreterTwoWayTC
|
||
|
}
|
||
|
|
||
|
prtInterpreterIndex OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value for each PDL or control language for which
|
||
|
there exists an interpreter or emulator in the printer. The
|
||
|
value is used to identify this interpreter. Although these
|
||
|
values may change due to a major reconfiguration of the device
|
||
|
(e.g., the addition of new interpreters to the printer), values
|
||
|
SHOULD remain stable across successive printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtInterpreterEntry 1 }
|
||
|
|
||
|
prtInterpreterLangFamily OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtInterpreterLangFamilyTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The family name of a Page Description Language (PDL) or
|
||
|
control language which this interpreter in the printer can
|
||
|
interpret or emulate.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtInterpreterEntry 2 }
|
||
|
|
||
|
prtInterpreterLangLevel OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The level of the language which this interpreter is
|
||
|
interpreting or emulating. This might contain a value like
|
||
|
'5e'for an interpreter which is emulating level 5e of the PCL
|
||
|
language. It might contain '2' for an interpreter which is
|
||
|
emulating level 2 of the PostScript language. Similarly it
|
||
|
might contain '2' for an interpreter which is emulating level 2
|
||
|
of the HPGL language."
|
||
|
::= { prtInterpreterEntry 3 }
|
||
|
|
||
|
prtInterpreterLangVersion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The date code or version of the language which this
|
||
|
interpreter is interpreting or emulating."
|
||
|
::= { prtInterpreterEntry 4 }
|
||
|
|
||
|
prtInterpreterDescription OBJECT-TYPE
|
||
|
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
|
-- to a TC to better support localization of the object.
|
||
|
SYNTAX PrtLocalizedDescriptionStringTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A string to identify this interpreter in the localization
|
||
|
specified by prtGeneralCurrentLocalization as opposed to the
|
||
|
language which is being interpreted. It is anticipated that
|
||
|
this string will allow manufacturers to unambiguously identify
|
||
|
their interpreters."
|
||
|
::= { prtInterpreterEntry 5 }
|
||
|
|
||
|
prtInterpreterVersion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..31))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The date code, version number, or other product specific
|
||
|
information tied to this interpreter. This value is associated
|
||
|
with the interpreter, rather than with the version of the
|
||
|
language which is being interpreted or emulated."
|
||
|
::= { prtInterpreterEntry 6 }
|
||
|
|
||
|
prtInterpreterDefaultOrientation OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtPrintOrientationTC
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The current orientation default for this interpreter. This
|
||
|
value may be overridden for a particular job (e.g., by a
|
||
|
command in the input data stream)."
|
||
|
::= { prtInterpreterEntry 7 }
|
||
|
|
||
|
prtInterpreterFeedAddressability OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum interpreter addressability in the feed
|
||
|
direction in 10000 prtMarkerAddressabilityUnits (as specified
|
||
|
by prtMarkerDefaultIndex) for this interpreter. The
|
||
|
value (-1) means other and specifically indicates that the
|
||
|
sub-unit places no restrictions on this parameter. The value
|
||
|
(-2) means unknown.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtInterpreterEntry 8 }
|
||
|
|
||
|
prtInterpreterXFeedAddressability OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum interpreter addressability in the cross feed
|
||
|
direction in 10000 prtMarkerAddressabilityUnits (as specified
|
||
|
by prtMarkerDefaultIndex) for this interpreter. The
|
||
|
value (-1) means other and specifically indicates that the
|
||
|
sub-unit places no restrictions on this parameter. The value
|
||
|
(-2) means unknown.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtInterpreterEntry 9 }
|
||
|
|
||
|
prtInterpreterDefaultCharSetIn OBJECT-TYPE
|
||
|
SYNTAX IANACharset
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The default coded character set for input octets encountered
|
||
|
outside a context in which the Page Description Language
|
||
|
established the interpretation of the octets. (Input octets are
|
||
|
presented to the interpreter through a path defined in the
|
||
|
channel group.)"
|
||
|
::= { prtInterpreterEntry 10 }
|
||
|
|
||
|
prtInterpreterDefaultCharSetOut OBJECT-TYPE
|
||
|
SYNTAX IANACharset
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The default character set for data coming from this
|
||
|
interpreter through the printer's output channel (i.e. the
|
||
|
'backchannel')."
|
||
|
::= { prtInterpreterEntry 11 }
|
||
|
|
||
|
prtInterpreterTwoWay OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtInterpreterTwoWayTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates whether or not this interpreter returns information
|
||
|
back to the host."
|
||
|
::= { prtInterpreterEntry 12 }
|
||
|
|
||
|
-- The Console Group
|
||
|
--
|
||
|
-- Many printers have a console on the printer, the operator
|
||
|
-- console, that is used to display and modify the state of the
|
||
|
-- printer. The console can be as simple as a few indicators and
|
||
|
-- switches or as complicated as full screen displays and
|
||
|
-- keyboards. There can be at most one such console.
|
||
|
|
||
|
-- The Display Buffer Table
|
||
|
|
||
|
prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }
|
||
|
|
||
|
prtConsoleDisplayBufferTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtConsoleDisplayBufferEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Physical display buffer for printer console display or
|
||
|
operator panel
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtConsoleDisplayBuffer 5 }
|
||
|
|
||
|
prtConsoleDisplayBufferEntry OBJECT-TYPE
|
||
|
SYNTAX PrtConsoleDisplayBufferEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table contains one entry for each physical line on
|
||
|
the display. Lines cannot be added or deleted. Entries may
|
||
|
exist in the table for each device index with a device type of
|
||
|
'printer'.
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtConsoleDisplayBufferIndex }
|
||
|
::= { prtConsoleDisplayBufferTable 1 }
|
||
|
|
||
|
PrtConsoleDisplayBufferEntry ::= SEQUENCE {
|
||
|
prtConsoleDisplayBufferIndex Integer32,
|
||
|
prtConsoleDisplayBufferText PrtConsoleDescriptionStringTC
|
||
|
}
|
||
|
|
||
|
prtConsoleDisplayBufferIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value for each console line in the printer. The value
|
||
|
is used to identify this console line. Although these values
|
||
|
may change due to a major reconfiguration of the device (e.g.,
|
||
|
the addition of new console lines to the printer). Values
|
||
|
SHOULD remain stable across successive printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtConsoleDisplayBufferEntry 1 }
|
||
|
|
||
|
prtConsoleDisplayBufferText OBJECT-TYPE
|
||
|
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
|
-- to a TC to better support localization of the object.
|
||
|
SYNTAX PrtConsoleDescriptionStringTC
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The content of a line in the logical display buffer of
|
||
|
the operator's console of the printer. When a write
|
||
|
operation occurs, normally a critical message, to one of
|
||
|
the LineText strings, the agent should make that line
|
||
|
displayable if a physical display is present. Writing a zero
|
||
|
length string clears the line. It is an implementation-
|
||
|
specific matter as to whether the agent allows a line to be
|
||
|
overwritten before it has been cleared. Printer generated
|
||
|
strings shall be in the localization specified by
|
||
|
prtConsoleLocalization.Management Application generated strings
|
||
|
should be localized by the Management Application."
|
||
|
::= { prtConsoleDisplayBufferEntry 2 }
|
||
|
|
||
|
-- The Console Light Table
|
||
|
|
||
|
prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 }
|
||
|
|
||
|
prtConsoleLightTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtConsoleLightEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The console light table provides a description and state
|
||
|
information for each light present on the printer console.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtConsoleLights 6 }
|
||
|
|
||
|
prtConsoleLightEntry OBJECT-TYPE
|
||
|
SYNTAX PrtConsoleLightEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Entries may exist in the table for each device index with a
|
||
|
device type of 'printer'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtConsoleLightIndex }
|
||
|
::= { prtConsoleLightTable 1 }
|
||
|
|
||
|
PrtConsoleLightEntry ::= SEQUENCE {
|
||
|
prtConsoleLightIndex Integer32,
|
||
|
prtConsoleOnTime Integer32,
|
||
|
prtConsoleOffTime Integer32,
|
||
|
prtConsoleColor PrtConsoleColorTC,
|
||
|
prtConsoleDescription PrtConsoleDescriptionStringTC
|
||
|
}
|
||
|
|
||
|
prtConsoleLightIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..65535) -- Lower limit invalid in RFC 1759
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A unique value used by the printer to identify this light.
|
||
|
Although these values may change due to a major
|
||
|
reconfiguration of the device (e.g., the addition of new lights
|
||
|
to the printer). Values SHOULD remain stable across successive
|
||
|
printer power cycles.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtConsoleLightEntry 1 }
|
||
|
|
||
|
prtConsoleOnTime OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (0..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object, in conjunction with prtConsoleOffTime, defines
|
||
|
the current status of the light. If both prtConsoleOnTime and
|
||
|
prtConsoleOffTime are non-zero, the lamp is blinking and the
|
||
|
values presented define the on time and off time, respectively,
|
||
|
in milliseconds. If prtConsoleOnTime is zero and
|
||
|
prtConsoleOffTime is non-zero, the lamp is off. If
|
||
|
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, the
|
||
|
lamp is on. If both values are zero the lamp is off.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtConsoleLightEntry 2 }
|
||
|
|
||
|
prtConsoleOffTime OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (0..2147483647)
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object, in conjunction with prtConsoleOnTime, defines the
|
||
|
current status of the light. If both prtConsoleOnTime and
|
||
|
prtConsoleOffTime are non-zero, the lamp is blinking and the
|
||
|
values presented define the on time and off time, respectively,
|
||
|
in milliseconds. If prtConsoleOnTime is zero and
|
||
|
prtConsoleOffTime is non-zero, the lamp is off. If
|
||
|
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero, the
|
||
|
lamp is on. If both values are zero the lamp is off.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtConsoleLightEntry 3 }
|
||
|
|
||
|
prtConsoleColor OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtConsoleColorTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The color of this light."
|
||
|
::= { prtConsoleLightEntry 4 }
|
||
|
|
||
|
prtConsoleDescription OBJECT-TYPE
|
||
|
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
|
-- to a TC to better support localization of the object.
|
||
|
SYNTAX PrtConsoleDescriptionStringTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The vendor description or label of this light in the
|
||
|
localization specified by prtConsoleLocalization."
|
||
|
::= { prtConsoleLightEntry 5 }
|
||
|
|
||
|
-- The Alerts Group
|
||
|
--
|
||
|
-- The table contains information on the severity, component,
|
||
|
-- detail location within the component, alert code and
|
||
|
-- description of each critical alert that is currently active
|
||
|
-- within the printer. See 2.2.13 for a more complete
|
||
|
-- description of the alerts table and its management.
|
||
|
--
|
||
|
-- Each parameter in the Trap PDU is a full OID which itself is
|
||
|
-- indexed by the host resources MIB "hrDeviceIndex" object. In
|
||
|
-- order for a management station to obtain the correct
|
||
|
-- "hrDeviceIndex" associated with a particular Trap PDU, the
|
||
|
-- "hrDeviceIndex" value can be extracted from the returned OID
|
||
|
-- value in the Trap PDU when the PDU is received by the
|
||
|
-- Management station.
|
||
|
|
||
|
prtAlert OBJECT IDENTIFIER ::= { printmib 18 }
|
||
|
|
||
|
prtAlertTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PrtAlertEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The prtAlertTable lists all the critical and non-critical
|
||
|
alerts currently active in the printer. A critical alert is
|
||
|
one that stops the printer from printing immediately and
|
||
|
printing can not continue until the critical alert condition
|
||
|
is eliminated. Non-critical alerts are those items that do
|
||
|
not stop printing but may at some future time.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtAlert 1 }
|
||
|
|
||
|
prtAlertEntry OBJECT-TYPE
|
||
|
SYNTAX PrtAlertEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Entries may exist in the table for each device
|
||
|
index with a device type of 'printer'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
INDEX { hrDeviceIndex, prtAlertIndex }
|
||
|
::= { prtAlertTable 1 }
|
||
|
|
||
|
PrtAlertEntry ::= SEQUENCE {
|
||
|
prtAlertIndex Integer32,
|
||
|
prtAlertSeverityLevel PrtAlertSeverityLevelTC,
|
||
|
prtAlertTrainingLevel PrtAlertTrainingLevelTC,
|
||
|
prtAlertGroup PrtAlertGroupTC,
|
||
|
prtAlertGroupIndex Integer32,
|
||
|
prtAlertLocation Integer32,
|
||
|
prtAlertCode PrtAlertCodeTC,
|
||
|
prtAlertDescription PrtLocalizedDescriptionStringTC,
|
||
|
prtAlertTime TimeTicks
|
||
|
}
|
||
|
|
||
|
prtAlertIndex OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined. The MAX-ACCESS has
|
||
|
-- been changed from not accessible to allow the object to be
|
||
|
-- included (as originally in RFC 1759) in the trap bindings.
|
||
|
|
||
|
SYNTAX Integer32 (1..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The index value used to determine which alerts have been added
|
||
|
or removed from the alert table. This is an incrementing
|
||
|
integer initialized to 1 when the printer is reset. (i.e., The
|
||
|
first event placed in the alert table after a reset of the
|
||
|
printer shall have an index value of 1.) When the printer adds
|
||
|
an alert to the table, that alert is assigned the next higher
|
||
|
integer value from the last item entered into the table. If
|
||
|
the index value reaches its maximum value, the next index value
|
||
|
used must be 1.
|
||
|
|
||
|
NOTE: The management application will read the alert table when
|
||
|
a trap or event notification occurs or at a periodic rate and
|
||
|
then parse the table to determine if any new entries were added
|
||
|
by comparing the last known index value with the current
|
||
|
highest index value. The management application will then
|
||
|
update its copy of the alert table. When the printer discovers
|
||
|
that an alert is no longer active, the printer shall remove the
|
||
|
row for that alert from the table and shall reduce the number
|
||
|
of rows in the table. The printer may add or delete any number
|
||
|
of rows from the table at any time. The management station can
|
||
|
detect when binary change alerts have been deleted by
|
||
|
requesting an attribute of each alert, and noting alerts as
|
||
|
deleted when that retrieval is not possible. The objects
|
||
|
'prtAlertCriticalEvents'and 'prtAlertAllEvents' in the
|
||
|
'prtGeneralTable' reduce the need for management applications
|
||
|
to scan the 'prtAlertTable'.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtAlertEntry 1 }
|
||
|
|
||
|
prtAlertSeverityLevel OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtAlertSeverityLevelTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The level of severity of this alert table entry. The printer
|
||
|
determines the severity level assigned to each entry into the
|
||
|
table."
|
||
|
::= { prtAlertEntry 2 }
|
||
|
|
||
|
prtAlertTrainingLevel OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtAlertTrainingLevelTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"See TEXTUAL-CONVENTION PrtAlertTrainingLevelTC.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtAlertEntry 3 }
|
||
|
|
||
|
prtAlertGroup OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtAlertGroupTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The type of sub-unit within the printer model that this alert
|
||
|
is related. Input, output, and markers are examples of printer
|
||
|
model groups, i.e., examples of types of sub-units. Wherever
|
||
|
possible, these enumerations match the sub-identifier that
|
||
|
identifies the relevant table in the printmib."
|
||
|
::= { prtAlertEntry 4 }
|
||
|
|
||
|
prtAlertGroupIndex OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-1..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The low-order index of the row within the table identified
|
||
|
by prtAlertGroup that represents the sub-unit of the printer
|
||
|
that caused this alert, or -1 if not applicable. The
|
||
|
combination of the prtAlertGroup and the prtAlertGroupIndex
|
||
|
defines exactly which printer sub-unit caused the alert; for
|
||
|
example, Input #3, Output#2, and Marker #1. Every object in
|
||
|
this MIB is indexed with hrDeviceIndex and optionally, another
|
||
|
index variable. If this other index variable is present in the
|
||
|
table that generated the alert, it will be used as the value
|
||
|
for this object. Otherwise, this value shall be -1.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtAlertEntry 5 }
|
||
|
|
||
|
prtAlertLocation OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the range was not defined.
|
||
|
SYNTAX Integer32 (-2..2147483647)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The sub-unit location that is defined by the printer
|
||
|
manufacturer to further refine the location of this alert
|
||
|
within the designated sub-unit. The location is used in
|
||
|
conjunction with the Group and GroupIndex values; for example,
|
||
|
there is an alert in Input #2 at location number 7. The value
|
||
|
(-2) indicates unknown.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtAlertEntry 6 }
|
||
|
|
||
|
prtAlertCode OBJECT-TYPE
|
||
|
-- NOTE: In RFC 1759, the enumeration values were implicitly
|
||
|
-- defined by this object.
|
||
|
SYNTAX PrtAlertCodeTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"See associated TEXTUAL-CONVENTION PrtAlertCodeTC.
|
||
|
|
||
|
NOTE: The above description has been modified from RFC 1759
|
||
|
for clarification."
|
||
|
::= { prtAlertEntry 7 }
|
||
|
|
||
|
prtAlertDescription OBJECT-TYPE
|
||
|
-- In RFC 1759, the SYNTAX was OCTET STRING. This has been changed
|
||
|
-- to a TC to better support localization of the object.
|
||
|
SYNTAX PrtLocalizedDescriptionStringTC
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A description of this alert entry in the localization
|
||
|
specified by prtGeneralCurrentLocalization. The description is
|
||
|
provided by the printer to further elaborate on the enumerated
|
||
|
alert or provide information in the case where the code is
|
||
|
classified as 'other' or 'unknown'. The printer is required to
|
||
|
return a description string but the string may be a null
|
||
|
string."
|
||
|
::= { prtAlertEntry 8 }
|
||
|
|
||
|
prtAlertTime OBJECT-TYPE
|
||
|
SYNTAX TimeTicks
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of sysUpTime at the time that this alert was
|
||
|
generated."
|
||
|
::= { prtAlertEntry 9 }
|
||
|
|
||
|
printerV1Alert OBJECT-IDENTITY
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of the enterprise-specific OID in an SNMPv1 trap
|
||
|
sent signaling a critical event in the prtAlertTable."
|
||
|
::= { prtAlert 2 }
|
||
|
|
||
|
printerV2AlertPrefix OBJECT IDENTIFIER ::= { printerV1Alert 0 }
|
||
|
|
||
|
printerV2Alert NOTIFICATION-TYPE
|
||
|
OBJECTS { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup,
|
||
|
prtAlertGroupIndex, prtAlertLocation, prtAlertCode }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This trap is sent whenever a critical event is added to the
|
||
|
prtAlertTable.
|
||
|
|
||
|
NOTE: The prtAlertIndex object was redundantly included in the
|
||
|
bindings of the 'printerV2Alert' notification in RFC 1759, even
|
||
|
though the value exists in the instance qualifier of all the
|
||
|
other bindings. This object has been retained to provide
|
||
|
compatiblity with existing RFC 1759 implementaions."
|
||
|
::= { printerV2AlertPrefix 1 }
|
||
|
|
||
|
-- Note that the SNMPv2 to SNMPv1 translation rules dictate that
|
||
|
-- the preceding structure will result in SNMPv1 traps of the
|
||
|
-- following form:
|
||
|
--
|
||
|
-- printerAlert TRAP-TYPE
|
||
|
-- ENTERPRISE printerV1Alert
|
||
|
-- VARIABLES { prtAlertIndex, prtAlertSeverityLevel,
|
||
|
-- prtAlertGroup, prtAlertGroupIndex,
|
||
|
-- prtAlertLocation, prtAlertCode }
|
||
|
-- DESCRIPTION
|
||
|
-- "This trap is sent whenever a critical event is added
|
||
|
-- to the prtAlertTable."
|
||
|
-- ::= 1
|
||
|
|
||
|
-- Conformance Information
|
||
|
|
||
|
prtMIBConformance OBJECT IDENTIFIER ::= { printmib 2 }
|
||
|
|
||
|
-- compliance statements
|
||
|
|
||
|
prtMIBCompliance MODULE-COMPLIANCE
|
||
|
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The compliance statement for agents that implement the
|
||
|
printer MIB as defined by RFC 1759."
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS { prtGeneralGroup, prtInputGroup,
|
||
|
prtOutputGroup,
|
||
|
prtMarkerGroup, prtMediaPathGroup,
|
||
|
prtChannelGroup, prtInterpreterGroup,
|
||
|
prtConsoleGroup, prtAlertTableGroup }
|
||
|
OBJECT prtGeneralReset
|
||
|
SYNTAX INTEGER {
|
||
|
notResetting(3),
|
||
|
resetToNVRAM(5)
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement just these two states in this
|
||
|
object. Any additional states are optional."
|
||
|
|
||
|
OBJECT prtConsoleOnTime
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtConsoleOffTime
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
::= { prtMIBConformance 1 }
|
||
|
|
||
|
prtMIB2Compliance MODULE-COMPLIANCE
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The compliance statement for agents that implement the
|
||
|
printer MIB V2."
|
||
|
-- The changes from RFC 1759 fall into 2 categories:
|
||
|
-- 1. New objects plus existing objects with a MIN-ACCESS of
|
||
|
-- read-only are included. Existing objects have been added
|
||
|
-- to this category due to feedback from implementers and
|
||
|
-- interoperability testing. This allows products to be
|
||
|
-- be designed with a higher degree of SNMP security.
|
||
|
-- 2. New object groups have been added to include all new
|
||
|
-- objects in this MIB. All new object groups are optional.
|
||
|
-- Any MIB that is compliant with RFC 1759 will also be
|
||
|
-- compliant with this version of the MIB.
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS { prtGeneralGroup, prtInputGroup,
|
||
|
prtOutputGroup,
|
||
|
prtMarkerGroup, prtMediaPathGroup,
|
||
|
prtChannelGroup, prtInterpreterGroup,
|
||
|
prtConsoleGroup, prtAlertTableGroup }
|
||
|
OBJECT prtGeneralReset
|
||
|
SYNTAX INTEGER {
|
||
|
notResetting(3),
|
||
|
resetToNVRAM(5)
|
||
|
}
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement just these two states in this
|
||
|
object. Any additional states are optional."
|
||
|
|
||
|
OBJECT prtGeneralCurrentLocalization
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtGeneralCurrentOperator
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtGeneralServicePerson
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtGeneralPrinterName
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtGeneralSerialNumber
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputDefaultIndex
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputMediaDimFeedDirDeclared
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputMaxCapacity
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputCurrentLevel
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputMediaName
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputName
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputSecurity
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputMediaWeight
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputMediaType
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputMediaColor
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputMediaFormParts
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputDefaultIndex
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputMaxCapacity
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputRemainingCapacity
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputName
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputSecurity
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputMaxDimFeedDir
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputMaxDimXFeedDir
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputMinDimFeedDir
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputMinDimXFeedDir
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputStackingOrder
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputPageDeliveryOrientation
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputBursting
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputDecollating
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputPageCollated
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtOutputOffsetStacking
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtMarkerDefaultIndex
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtMarkerSuppliesMaxCapacity
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtMarkerSuppliesLevel
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtMediaPathDefaultIndex
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtChannelCurrentJobCntlLangIndex
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtChannelDefaultPageDescLangIndex
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtChannelState
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtChannelIfIndex
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInterpreterDefaultOrientation
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInterpreterDefaultCharSetIn
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInterpreterDefaultCharSetOut
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtConsoleLocalization
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtConsoleDisable
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtConsoleDisplayBufferText
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtConsoleOnTime
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtConsoleOffTime
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtAlertIndex
|
||
|
MIN-ACCESS accessible-for-notify
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as
|
||
|
accessible-for-notify "
|
||
|
|
||
|
GROUP prtResponsiblePartyGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtExtendedInputGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtInputMediaGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtExtendedOutputGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtOutputDimensionsGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtOutputFeaturesGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtMarkerSuppliesGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtMarkerColorantGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtAlertTimeGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
-- the prtResponsiblePartyGroup, prtExtendedInputGroup,
|
||
|
-- prtInputMediaGroup, prtExtendedOutputGroup,
|
||
|
-- prtOutputDimensionsGroup, prtOutputFeaturesGroup,
|
||
|
-- prtMarkerSuppliesGroup, prtMarkerColorantGroup, and the
|
||
|
-- prtAlertTimeGroup are completely optional. However, it is
|
||
|
-- strongly RECOMMENDED that the prtAlertTimeGroup be implemented.
|
||
|
|
||
|
-- New to version 2 of this printer MIB:
|
||
|
OBJECT prtAuxiliarySheetStartupPage
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtAuxiliarySheetBannerPage
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputMediaLoadTimeout
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
OBJECT prtInputNextIndex
|
||
|
MIN-ACCESS read-only
|
||
|
DESCRIPTION
|
||
|
"It is conformant to implement this object as read-only"
|
||
|
|
||
|
GROUP prtAuxiliarySheetGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtInputSwitchingGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtGeneralV2Group
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtAlertTableV2Group
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtChannelV2Group
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
|
||
|
GROUP prtAlertTrapGroup
|
||
|
DESCRIPTION
|
||
|
"This group is unconditionally optional."
|
||
|
::= { prtMIBConformance 3 }
|
||
|
|
||
|
prtMIBGroups OBJECT IDENTIFIER ::= { prtMIBConformance 2 }
|
||
|
-- These groups are from RFC 1759 and are applicable to Printer MIB V2
|
||
|
|
||
|
prtGeneralGroup OBJECT-GROUP
|
||
|
OBJECTS { prtGeneralConfigChanges,
|
||
|
prtGeneralCurrentLocalization,
|
||
|
prtGeneralReset, prtCoverDescription,
|
||
|
prtCoverStatus,
|
||
|
prtLocalizationLanguage, prtLocalizationCountry,
|
||
|
prtLocalizationCharacterSet, prtStorageRefIndex,
|
||
|
prtDeviceRefIndex }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The general printer group."
|
||
|
::= { prtMIBGroups 1 }
|
||
|
|
||
|
prtResponsiblePartyGroup OBJECT-GROUP
|
||
|
OBJECTS { prtGeneralCurrentOperator, prtGeneralServicePerson }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The responsible party group contains contact information for
|
||
|
humans responsible for the printer."
|
||
|
::= { prtMIBGroups 2 }
|
||
|
|
||
|
prtInputGroup OBJECT-GROUP
|
||
|
OBJECTS { prtInputDefaultIndex, prtInputType, prtInputDimUnit,
|
||
|
prtInputMediaDimFeedDirDeclared,
|
||
|
prtInputMediaDimXFeedDirDeclared,
|
||
|
prtInputMediaDimFeedDirChosen,
|
||
|
prtInputMediaDimXFeedDirChosen, prtInputCapacityUnit,
|
||
|
prtInputMaxCapacity, prtInputCurrentLevel, prtInputStatus,
|
||
|
prtInputMediaName }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The input group."
|
||
|
::= { prtMIBGroups 3 }
|
||
|
|
||
|
prtExtendedInputGroup OBJECT-GROUP
|
||
|
OBJECTS { prtInputName, prtInputVendorName, prtInputModel,
|
||
|
prtInputVersion, prtInputSerialNumber,
|
||
|
prtInputDescription, prtInputSecurity }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The extended input group."
|
||
|
::= { prtMIBGroups 4 }
|
||
|
|
||
|
prtInputMediaGroup OBJECT-GROUP
|
||
|
OBJECTS { prtInputMediaWeight, prtInputMediaType,
|
||
|
prtInputMediaColor, prtInputMediaFormParts }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The input media group."
|
||
|
::= { prtMIBGroups 5 }
|
||
|
|
||
|
prtOutputGroup OBJECT-GROUP
|
||
|
OBJECTS { prtOutputDefaultIndex, prtOutputType,
|
||
|
prtOutputCapacityUnit, prtOutputMaxCapacity,
|
||
|
prtOutputRemainingCapacity, prtOutputStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The output group."
|
||
|
::= { prtMIBGroups 6 }
|
||
|
|
||
|
prtExtendedOutputGroup OBJECT-GROUP
|
||
|
OBJECTS { prtOutputName, prtOutputVendorName, prtOutputModel,
|
||
|
prtOutputVersion, prtOutputSerialNumber,
|
||
|
prtOutputDescription, prtOutputSecurity }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The extended output group."
|
||
|
::= { prtMIBGroups 7 }
|
||
|
|
||
|
prtOutputDimensionsGroup OBJECT-GROUP
|
||
|
OBJECTS { prtOutputDimUnit, prtOutputMaxDimFeedDir,
|
||
|
prtOutputMaxDimXFeedDir, prtOutputMinDimFeedDir,
|
||
|
prtOutputMinDimXFeedDir }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The output dimensions group"
|
||
|
::= { prtMIBGroups 8 }
|
||
|
|
||
|
prtOutputFeaturesGroup OBJECT-GROUP
|
||
|
OBJECTS { prtOutputStackingOrder,
|
||
|
prtOutputPageDeliveryOrientation, prtOutputBursting,
|
||
|
prtOutputDecollating, prtOutputPageCollated,
|
||
|
prtOutputOffsetStacking }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The output features group."
|
||
|
::= { prtMIBGroups 9 }
|
||
|
|
||
|
prtMarkerGroup OBJECT-GROUP
|
||
|
OBJECTS { prtMarkerDefaultIndex, prtMarkerMarkTech,
|
||
|
prtMarkerCounterUnit, prtMarkerLifeCount,
|
||
|
prtMarkerPowerOnCount, prtMarkerProcessColorants,
|
||
|
prtMarkerSpotColorants, prtMarkerAddressabilityUnit,
|
||
|
prtMarkerAddressabilityFeedDir,
|
||
|
prtMarkerAddressabilityXFeedDir, prtMarkerNorthMargin,
|
||
|
prtMarkerSouthMargin, prtMarkerWestMargin,
|
||
|
prtMarkerEastMargin, prtMarkerStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The marker group."
|
||
|
::= { prtMIBGroups 10 }
|
||
|
|
||
|
prtMarkerSuppliesGroup OBJECT-GROUP
|
||
|
OBJECTS { prtMarkerSuppliesMarkerIndex,
|
||
|
prtMarkerSuppliesColorantIndex, prtMarkerSuppliesClass,
|
||
|
prtMarkerSuppliesType, prtMarkerSuppliesDescription,
|
||
|
prtMarkerSuppliesSupplyUnit,
|
||
|
prtMarkerSuppliesMaxCapacity, prtMarkerSuppliesLevel }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The marker supplies group."
|
||
|
::= { prtMIBGroups 11 }
|
||
|
|
||
|
prtMarkerColorantGroup OBJECT-GROUP
|
||
|
OBJECTS { prtMarkerColorantMarkerIndex, prtMarkerColorantRole,
|
||
|
prtMarkerColorantValue, prtMarkerColorantTonality }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The marker colorant group."
|
||
|
::= { prtMIBGroups 12 }
|
||
|
|
||
|
prtMediaPathGroup OBJECT-GROUP
|
||
|
OBJECTS { prtMediaPathDefaultIndex, prtMediaPathMaxSpeedPrintUnit,
|
||
|
prtMediaPathMediaSizeUnit, prtMediaPathMaxSpeed,
|
||
|
prtMediaPathMaxMediaFeedDir,
|
||
|
prtMediaPathMaxMediaXFeedDir,
|
||
|
prtMediaPathMinMediaFeedDir,
|
||
|
prtMediaPathMinMediaXFeedDir, prtMediaPathType,
|
||
|
prtMediaPathDescription, prtMediaPathStatus}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The media path group."
|
||
|
::= { prtMIBGroups 13 }
|
||
|
|
||
|
prtChannelGroup OBJECT-GROUP
|
||
|
OBJECTS { prtChannelType, prtChannelProtocolVersion,
|
||
|
prtChannelCurrentJobCntlLangIndex,
|
||
|
prtChannelDefaultPageDescLangIndex, prtChannelState,
|
||
|
prtChannelIfIndex, prtChannelStatus
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The channel group."
|
||
|
::= { prtMIBGroups 14 }
|
||
|
|
||
|
prtInterpreterGroup OBJECT-GROUP
|
||
|
OBJECTS { prtInterpreterLangFamily, prtInterpreterLangLevel,
|
||
|
prtInterpreterLangVersion, prtInterpreterDescription,
|
||
|
prtInterpreterVersion, prtInterpreterDefaultOrientation,
|
||
|
prtInterpreterFeedAddressability,
|
||
|
prtInterpreterXFeedAddressability,
|
||
|
prtInterpreterDefaultCharSetIn,
|
||
|
prtInterpreterDefaultCharSetOut, prtInterpreterTwoWay }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The interpreter group."
|
||
|
::= { prtMIBGroups 15 }
|
||
|
|
||
|
prtConsoleGroup OBJECT-GROUP
|
||
|
OBJECTS { prtConsoleLocalization, prtConsoleNumberOfDisplayLines,
|
||
|
prtConsoleNumberOfDisplayChars, prtConsoleDisable,
|
||
|
prtConsoleDisplayBufferText, prtConsoleOnTime,
|
||
|
prtConsoleOffTime, prtConsoleColor,
|
||
|
prtConsoleDescription }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The console group."
|
||
|
::= { prtMIBGroups 16 }
|
||
|
|
||
|
prtAlertTableGroup OBJECT-GROUP
|
||
|
OBJECTS { prtAlertSeverityLevel, prtAlertTrainingLevel,
|
||
|
prtAlertGroup, prtAlertGroupIndex, prtAlertLocation,
|
||
|
prtAlertCode, prtAlertDescription }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The alert table group."
|
||
|
::= { prtMIBGroups 17 }
|
||
|
|
||
|
prtAlertTimeGroup OBJECT-GROUP
|
||
|
OBJECTS { prtAlertTime }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The alert time group. Implementation of prtAlertTime is
|
||
|
strongly RECOMMENDED."
|
||
|
::= { prtMIBGroups 18 }
|
||
|
|
||
|
prtMIB2Groups OBJECT IDENTIFIER ::= { prtMIBConformance 4 }
|
||
|
-- These groups are unique to Printer MIB V2
|
||
|
|
||
|
prtAuxiliarySheetGroup OBJECT-GROUP
|
||
|
OBJECTS { prtAuxiliarySheetStartupPage,
|
||
|
prtAuxiliarySheetBannerPage }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The auxiliary sheet group."
|
||
|
::= { prtMIBGroups 19 }
|
||
|
|
||
|
prtInputSwitchingGroup OBJECT-GROUP
|
||
|
OBJECTS { prtInputMediaLoadTimeout, prtInputNextIndex }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The input switching group."
|
||
|
::= { prtMIBGroups 20 }
|
||
|
|
||
|
prtGeneralV2Group OBJECT-GROUP
|
||
|
OBJECTS { prtGeneralPrinterName, prtGeneralSerialNumber }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The general printer group with new v2 objects."
|
||
|
::= { prtMIBGroups 21 }
|
||
|
|
||
|
prtAlertTableV2Group OBJECT-GROUP
|
||
|
OBJECTS { prtAlertIndex, prtAlertCriticalEvents, prtAlertAllEvents }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The alert table group with new v2 objects and prtAlertIndex
|
||
|
changed to MAX-ACCESS of 'read-only' for inclusion in the trap
|
||
|
bindings (as originally defined in RFC 1759)."
|
||
|
|
||
|
::= { prtMIBGroups 22 }
|
||
|
|
||
|
prtChannelV2Group OBJECT-GROUP
|
||
|
OBJECTS { prtChannelInformation }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The channel group with a new v2 object."
|
||
|
::= { prtMIBGroups 23 }
|
||
|
|
||
|
prtAlertTrapGroup NOTIFICATION-GROUP
|
||
|
NOTIFICATIONS { printerV2Alert }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The alert trap group."
|
||
|
::= { prtMIBGroups 24 }
|
||
|
|
||
|
END
|
||
|
|