1362 lines
31 KiB
Plaintext
1362 lines
31 KiB
Plaintext
|
FOUNDRY-SN-IPX-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
MODULE-IDENTITY, OBJECT-TYPE,Counter32,Integer32
|
||
|
FROM SNMPv2-SMI
|
||
|
TEXTUAL-CONVENTION
|
||
|
FROM SNMPv2-TC
|
||
|
router
|
||
|
FROM FOUNDRY-SN-ROOT-MIB
|
||
|
PhysAddress
|
||
|
FROM FOUNDRY-SN-SWITCH-GROUP-MIB;
|
||
|
|
||
|
snIpx MODULE-IDENTITY
|
||
|
LAST-UPDATED "201006020000Z" -- 04 June 2010
|
||
|
ORGANIZATION "Brocade Communications Systems, Inc."
|
||
|
CONTACT-INFO
|
||
|
"Technical Support Center
|
||
|
130 Holger Way,
|
||
|
San Jose, CA 95134
|
||
|
Email: ipsupport@brocade.com
|
||
|
Phone: 1-800-752-8061
|
||
|
URL: www.brocade.com"
|
||
|
DESCRIPTION
|
||
|
"Copyright 1996-2010 Brocade Communications Systems, Inc.
|
||
|
All rights reserved.
|
||
|
This Brocade Communications Systems SNMP Management Information Base Specification
|
||
|
embodies Brocade Communications Systems' confidential and proprietary
|
||
|
intellectual property. Brocade Communications Systems retains all
|
||
|
title and ownership in the Specification, including any revisions.
|
||
|
|
||
|
This Specification is supplied AS IS, and Brocade Communications Systems makes
|
||
|
no warranty, either express or implied, as to the use,
|
||
|
operation, condition, or performance of the specification, and any unintended
|
||
|
consequence it may on the user environment."
|
||
|
|
||
|
REVISION "201006020000Z" -- 04 June 2010
|
||
|
DESCRIPTION
|
||
|
"Changed the ORGANIZATION, CONTACT-INFO and DESCRIPTION fields."
|
||
|
|
||
|
REVISION "200909300000Z" -- September 30, 2009
|
||
|
DESCRIPTION
|
||
|
"convert from SMIv1 to SMIv2"
|
||
|
::= { router 1 }
|
||
|
-- textual conventions
|
||
|
|
||
|
RtrStatus ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"
|
||
|
RtrStatus Values
|
||
|
"
|
||
|
SYNTAX INTEGER { disabled(0), enabled (1) }
|
||
|
|
||
|
|
||
|
|
||
|
ClearStatus ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"
|
||
|
Clear Status Values
|
||
|
"
|
||
|
SYNTAX INTEGER { normal(0), clear(1) }
|
||
|
|
||
|
|
||
|
PortIndex ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"
|
||
|
The bits 0-7 = port number.
|
||
|
The bits 8-15 = slot number (slot for chassis only).
|
||
|
ve port format bits 16-24 = 0x01, bits 0-15 = ve number
|
||
|
loopback port format bits 16-24 = 0x02, bits 0-15= lb number
|
||
|
"
|
||
|
SYNTAX Integer32(1..3900)
|
||
|
|
||
|
|
||
|
Action ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"
|
||
|
Represents a action value such as deny or permit.
|
||
|
"
|
||
|
SYNTAX INTEGER { deny(0), permit(1) }
|
||
|
|
||
|
NetNumber::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"
|
||
|
"
|
||
|
SYNTAX OCTET STRING (SIZE(4))
|
||
|
|
||
|
-- SECTION 2: MIB
|
||
|
|
||
|
-- Router IPX MIB
|
||
|
|
||
|
snIpxGen OBJECT IDENTIFIER ::= { snIpx 1 }
|
||
|
snIpxCache OBJECT IDENTIFIER ::= { snIpx 2 }
|
||
|
snIpxRoute OBJECT IDENTIFIER ::= { snIpx 3 }
|
||
|
snIpxServer OBJECT IDENTIFIER ::= { snIpx 4 }
|
||
|
snIpxFwdFilter OBJECT IDENTIFIER ::= { snIpx 5 }
|
||
|
snIpxRipFilter OBJECT IDENTIFIER ::= { snIpx 6 }
|
||
|
snIpxSapFilter OBJECT IDENTIFIER ::= { snIpx 7 }
|
||
|
snIpxIfFwdAccess OBJECT IDENTIFIER ::= { snIpx 8 }
|
||
|
snIpxIfRipAccess OBJECT IDENTIFIER ::= { snIpx 9 }
|
||
|
snIpxIfSapAccess OBJECT IDENTIFIER ::= { snIpx 10 }
|
||
|
snIpxPortAddr OBJECT IDENTIFIER ::= { snIpx 11 }
|
||
|
snIpxPortCounters OBJECT IDENTIFIER ::= { snIpx 12 }
|
||
|
|
||
|
-- IPX General MIBs
|
||
|
|
||
|
snIpxRoutingMode OBJECT-TYPE
|
||
|
SYNTAX RtrStatus
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enabled/Disabled System IPX Routing Mode status."
|
||
|
::= { snIpxGen 1 }
|
||
|
|
||
|
snIpxNetBiosFilterMode OBJECT-TYPE
|
||
|
SYNTAX RtrStatus
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enabled/Disabled NetBios Filter Mode status."
|
||
|
::= { snIpxGen 2 }
|
||
|
|
||
|
|
||
|
snIpxClearCache OBJECT-TYPE
|
||
|
SYNTAX ClearStatus
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"clear(1) will clear cache table."
|
||
|
::= { snIpxGen 3 }
|
||
|
|
||
|
snIpxClearRoute OBJECT-TYPE
|
||
|
SYNTAX ClearStatus
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"clear(1) will clear ipx route table."
|
||
|
::= { snIpxGen 4 }
|
||
|
|
||
|
snIpxClearTrafficCnts OBJECT-TYPE
|
||
|
SYNTAX ClearStatus
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"clear(1) will clear ipx all traffic counters.
|
||
|
- snIpxRcvPktsCnt, snIpxFwdPktsCnt,
|
||
|
snIpxRcvDropPktsCnt, snIpxTxDropPktsCnt,
|
||
|
snIpxRcvFiltPktsCnt, snIpxTxFiltPktsCnt."
|
||
|
::= { snIpxGen 5 }
|
||
|
|
||
|
|
||
|
snIpxRcvPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX incoming packets counter."
|
||
|
::= { snIpxGen 6 }
|
||
|
|
||
|
|
||
|
snIpxTxPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX Outgoing packets counter."
|
||
|
::= { snIpxGen 7 }
|
||
|
|
||
|
|
||
|
snIpxFwdPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX forwarding packets counter."
|
||
|
::= { snIpxGen 8 }
|
||
|
|
||
|
snIpxRcvDropPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX receiving drop packets counter."
|
||
|
::= { snIpxGen 9 }
|
||
|
|
||
|
snIpxRcvFiltPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX receiving filter packets counter."
|
||
|
::= { snIpxGen 10 }
|
||
|
|
||
|
snIpxRipGblFiltList OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING(SIZE(0..32))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An IPX RIP Global Filter List. Null value indicates no filter list."
|
||
|
::= { snIpxGen 11 }
|
||
|
|
||
|
snIpxRipFiltOnAllPort OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
valid(1),
|
||
|
deleteAllInBound(2),
|
||
|
deleteAllOutBound(3),
|
||
|
addAllInBound(4),
|
||
|
addAllOutBound(5)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Apply the IPX RIP Global filter list snIpxRipGblFiltList to
|
||
|
all interfaces. This object is used to add all RIP filter
|
||
|
lists and delete all RIP filter lists to/from all ports.
|
||
|
Prior to sending this command, snIpxRipGblFiltList must be ready.
|
||
|
The values that can be written are:
|
||
|
deleteAllInBound(2)...delete all in-bound filter lists from all ports.
|
||
|
deleteAllOutBound(3)..delete all out-bound filter lists from all ports.
|
||
|
addAllInBound(4)......add all in-bound filter lists to all ports.
|
||
|
addAllOutBound(5).....add all out-bound filter lists to all ports.
|
||
|
|
||
|
If set operation is failed, then a SET with
|
||
|
value of (2)or(3) returns error 'GenError'.
|
||
|
Deleted(2)&(3) go away immediately.
|
||
|
The following values can be returned on reads:
|
||
|
noSuch(0)...no such operation yet.
|
||
|
valid(1)....set operation is done and is valid"
|
||
|
|
||
|
::= { snIpxGen 12 }
|
||
|
|
||
|
snIpxSapGblFiltList OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING(SIZE(0..32))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An IPX SAP Global Filter List. Null value indicates no filter list"
|
||
|
::= { snIpxGen 13 }
|
||
|
|
||
|
|
||
|
snIpxSapFiltOnAllPort OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
valid(1),
|
||
|
deleteAllInBound(2),
|
||
|
deleteAllOutBound(3),
|
||
|
addAllInBound(4),
|
||
|
addAllOutBound(5)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Apply the IPX SAP Global filter list snIpxSapGblFiltList to
|
||
|
all interfaces. This object is used to add all RIP filter
|
||
|
lists and delete all SAP filter lists to/from all ports.
|
||
|
Prior to sending this command, snIpxSapGblFiltList must be ready.
|
||
|
The values that can be written are:
|
||
|
deleteAllInBound(2)...delete all in-bound filter lists from all ports.
|
||
|
deleteAllOutBound(3)..delete all out-bound filter lists from all ports.
|
||
|
addAllInBound(4)......add all in-bound filter lists to all ports.
|
||
|
addAllOutBound(5).....add all out-bound filter lists to all ports.
|
||
|
|
||
|
If set operation is failed, then a SET with
|
||
|
value of (2)or(3) returns error 'GenError'.
|
||
|
Deleted(2)&(3) go away immediately.
|
||
|
The following values can be returned on reads:
|
||
|
noSuch(0)...no such operation yet.
|
||
|
valid(1)....set operation is done and is valid"
|
||
|
::= { snIpxGen 14 }
|
||
|
|
||
|
snIpxTxDropPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX transmitting drop packets counter."
|
||
|
::= { snIpxGen 15 }
|
||
|
|
||
|
snIpxTxFiltPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX transmitting filter packets counter."
|
||
|
::= { snIpxGen 16 }
|
||
|
|
||
|
|
||
|
-- IPX Cache table
|
||
|
|
||
|
snIpxCacheTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SnIpxCacheEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX Cache table."
|
||
|
::= { snIpxCache 1 }
|
||
|
|
||
|
snIpxCacheEntry OBJECT-TYPE
|
||
|
SYNTAX SnIpxCacheEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the IPX Cache table."
|
||
|
INDEX { snIpxCacheIndex }
|
||
|
::= { snIpxCacheTable 1 }
|
||
|
|
||
|
SnIpxCacheEntry ::= SEQUENCE {
|
||
|
snIpxCacheIndex
|
||
|
Integer32,
|
||
|
snIpxCacheNetNum
|
||
|
NetNumber,
|
||
|
snIpxCacheNode
|
||
|
PhysAddress,
|
||
|
snIpxCacheOutFilter
|
||
|
RtrStatus,
|
||
|
snIpxCacheEncap
|
||
|
INTEGER,
|
||
|
snIpxCachePort
|
||
|
PortIndex
|
||
|
}
|
||
|
|
||
|
snIpxCacheIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The table index for a IPX Cache entry."
|
||
|
::= { snIpxCacheEntry 1 }
|
||
|
|
||
|
|
||
|
snIpxCacheNetNum OBJECT-TYPE
|
||
|
SYNTAX NetNumber
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Cache Network number."
|
||
|
::= { snIpxCacheEntry 2 }
|
||
|
|
||
|
snIpxCacheNode OBJECT-TYPE
|
||
|
SYNTAX PhysAddress
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Cache Node Number."
|
||
|
::= { snIpxCacheEntry 3 }
|
||
|
|
||
|
snIpxCacheOutFilter OBJECT-TYPE
|
||
|
SYNTAX RtrStatus
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Cache Outbound Filter is ether disabled(0) or enabled(1)."
|
||
|
::= { snIpxCacheEntry 4 }
|
||
|
|
||
|
snIpxCacheEncap OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ethernetII(1),
|
||
|
ethernet8022(2),
|
||
|
ethernet8023(3),
|
||
|
ethernetSnap(4)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The IPX encapsulation frame type."
|
||
|
::= { snIpxCacheEntry 5 }
|
||
|
|
||
|
|
||
|
snIpxCachePort OBJECT-TYPE
|
||
|
SYNTAX PortIndex
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX Router Port number."
|
||
|
::= { snIpxCacheEntry 6 }
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
-- IPX route table
|
||
|
|
||
|
snIpxRouteTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SnIpxRouteEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX route table."
|
||
|
::= { snIpxRoute 1 }
|
||
|
|
||
|
snIpxRouteEntry OBJECT-TYPE
|
||
|
SYNTAX SnIpxRouteEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the IPX route table."
|
||
|
INDEX { snIpxRouteIndex }
|
||
|
::= { snIpxRouteTable 1 }
|
||
|
|
||
|
SnIpxRouteEntry ::= SEQUENCE {
|
||
|
snIpxRouteIndex
|
||
|
Integer32,
|
||
|
snIpxDestNetNum
|
||
|
NetNumber,
|
||
|
snIpxFwdRouterNode
|
||
|
PhysAddress,
|
||
|
snIpxDestHopCnts
|
||
|
Integer32,
|
||
|
snIpxRouteMetric
|
||
|
Integer32,
|
||
|
snIpxDestPort
|
||
|
Integer32
|
||
|
}
|
||
|
|
||
|
snIpxRouteIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The table index for a IPX route entry."
|
||
|
::= { snIpxRouteEntry 1 }
|
||
|
|
||
|
snIpxDestNetNum OBJECT-TYPE
|
||
|
SYNTAX NetNumber
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Destination Network number."
|
||
|
::= { snIpxRouteEntry 2 }
|
||
|
|
||
|
snIpxFwdRouterNode OBJECT-TYPE
|
||
|
SYNTAX PhysAddress
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Forward Router Node Number."
|
||
|
::= { snIpxRouteEntry 3 }
|
||
|
|
||
|
snIpxDestHopCnts OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of hops to reach the
|
||
|
destination."
|
||
|
::= { snIpxRouteEntry 4 }
|
||
|
|
||
|
snIpxRouteMetric OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The metrics to next hop router."
|
||
|
::= { snIpxRouteEntry 5 }
|
||
|
|
||
|
snIpxDestPort OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The destination port."
|
||
|
::= { snIpxRouteEntry 6 }
|
||
|
|
||
|
|
||
|
-- IPX Server table
|
||
|
|
||
|
snIpxServerTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SnIpxServerEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX Server table."
|
||
|
::= { snIpxServer 1 }
|
||
|
|
||
|
snIpxServerEntry OBJECT-TYPE
|
||
|
SYNTAX SnIpxServerEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the IPX Server table."
|
||
|
INDEX { snIpxServerIndex }
|
||
|
::= { snIpxServerTable 1 }
|
||
|
|
||
|
SnIpxServerEntry ::= SEQUENCE {
|
||
|
snIpxServerIndex
|
||
|
Integer32,
|
||
|
snIpxServerType
|
||
|
Integer32,
|
||
|
snIpxServerNetNum
|
||
|
NetNumber,
|
||
|
snIpxServerNode
|
||
|
PhysAddress,
|
||
|
snIpxServerSocket
|
||
|
Integer32,
|
||
|
snIpxServerHopCnts
|
||
|
Integer32,
|
||
|
snIpxServerName
|
||
|
OCTET STRING
|
||
|
}
|
||
|
|
||
|
snIpxServerIndex OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The table index for a IPX Server entry."
|
||
|
::= { snIpxServerEntry 1 }
|
||
|
|
||
|
|
||
|
snIpxServerType OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX Server Type."
|
||
|
::= { snIpxServerEntry 2 }
|
||
|
|
||
|
snIpxServerNetNum OBJECT-TYPE
|
||
|
SYNTAX NetNumber
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Server Network number."
|
||
|
::= { snIpxServerEntry 3 }
|
||
|
|
||
|
snIpxServerNode OBJECT-TYPE
|
||
|
SYNTAX PhysAddress
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Server Node Number."
|
||
|
::= { snIpxServerEntry 4 }
|
||
|
|
||
|
snIpxServerSocket OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Server Socket Number."
|
||
|
::= { snIpxServerEntry 5 }
|
||
|
|
||
|
snIpxServerHopCnts OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of intervening networks to reach the
|
||
|
server."
|
||
|
::= { snIpxServerEntry 6 }
|
||
|
|
||
|
|
||
|
snIpxServerName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING(SIZE(0..47))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX Server Name."
|
||
|
::= { snIpxServerEntry 7 }
|
||
|
|
||
|
|
||
|
|
||
|
-- IPX Forward Filter table
|
||
|
|
||
|
snIpxFwdFilterTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SnIpxFwdFilterEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX Forward Filter table."
|
||
|
::= { snIpxFwdFilter 1 }
|
||
|
|
||
|
snIpxFwdFilterEntry OBJECT-TYPE
|
||
|
SYNTAX SnIpxFwdFilterEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the IPX Forward Filter table."
|
||
|
INDEX { snIpxFwdFilterIdx }
|
||
|
::= { snIpxFwdFilterTable 1 }
|
||
|
|
||
|
SnIpxFwdFilterEntry ::= SEQUENCE {
|
||
|
snIpxFwdFilterIdx
|
||
|
Integer32,
|
||
|
snIpxFwdFilterAction
|
||
|
Action,
|
||
|
snIpxFwdFilterSocket
|
||
|
Integer32,
|
||
|
snIpxFwdFilterSrcNet
|
||
|
NetNumber,
|
||
|
snIpxFwdFilterSrcNode
|
||
|
PhysAddress,
|
||
|
snIpxFwdFilterDestNet
|
||
|
NetNumber,
|
||
|
snIpxFwdFilterDestNode
|
||
|
PhysAddress,
|
||
|
snIpxFwdFilterRowStatus
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
snIpxFwdFilterIdx OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The filter ID for a filter entry."
|
||
|
::= { snIpxFwdFilterEntry 1 }
|
||
|
|
||
|
snIpxFwdFilterAction OBJECT-TYPE
|
||
|
SYNTAX Action
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Action to take if the ipx packet match
|
||
|
with this filter."
|
||
|
::= { snIpxFwdFilterEntry 2 }
|
||
|
|
||
|
snIpxFwdFilterSocket OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX Forward Filter Socket Number."
|
||
|
::= { snIpxFwdFilterEntry 3 }
|
||
|
|
||
|
snIpxFwdFilterSrcNet OBJECT-TYPE
|
||
|
SYNTAX NetNumber
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Source Network Number."
|
||
|
::= { snIpxFwdFilterEntry 4 }
|
||
|
|
||
|
snIpxFwdFilterSrcNode OBJECT-TYPE
|
||
|
SYNTAX PhysAddress
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Source Node Number."
|
||
|
::= { snIpxFwdFilterEntry 5 }
|
||
|
|
||
|
snIpxFwdFilterDestNet OBJECT-TYPE
|
||
|
SYNTAX NetNumber
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Destination Network Number."
|
||
|
::= { snIpxFwdFilterEntry 6 }
|
||
|
|
||
|
snIpxFwdFilterDestNode OBJECT-TYPE
|
||
|
SYNTAX PhysAddress
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Destination Node Number."
|
||
|
::= { snIpxFwdFilterEntry 7 }
|
||
|
|
||
|
snIpxFwdFilterRowStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
invalid(1),
|
||
|
valid(2),
|
||
|
delete(3),
|
||
|
create(4),
|
||
|
modify(5)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to create and
|
||
|
delete row in the table and control
|
||
|
if they are used. The values
|
||
|
that can be written are:
|
||
|
delete(3)...deletes the row
|
||
|
create(4)...creates a new row
|
||
|
modify(5)...modifies an exsisting row
|
||
|
|
||
|
If the row exists, then a SET with
|
||
|
value of create(4) returns error
|
||
|
'badValue'. Deleted rows go away
|
||
|
immediately. The following values
|
||
|
can be returned on reads:
|
||
|
noSuch(0)...no such row
|
||
|
invalid(1)...Setting it to 'invalid' has the effect of
|
||
|
rendering it inoperative..
|
||
|
valid(2)....the row exists and is valid"
|
||
|
::= { snIpxFwdFilterEntry 8 }
|
||
|
|
||
|
|
||
|
|
||
|
-- IPX RIP Filter table
|
||
|
|
||
|
snIpxRipFilterTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SnIpxRipFilterEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX RIP Filter table."
|
||
|
::= { snIpxRipFilter 1 }
|
||
|
|
||
|
snIpxRipFilterEntry OBJECT-TYPE
|
||
|
SYNTAX SnIpxRipFilterEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the IPX RIP Filter table."
|
||
|
INDEX { snIpxRipFilterId }
|
||
|
::= { snIpxRipFilterTable 1 }
|
||
|
|
||
|
SnIpxRipFilterEntry ::= SEQUENCE {
|
||
|
snIpxRipFilterId
|
||
|
Integer32,
|
||
|
snIpxRipFilterAction
|
||
|
Action,
|
||
|
snIpxRipFilterNet
|
||
|
NetNumber,
|
||
|
snIpxRipFilterMask
|
||
|
NetNumber,
|
||
|
snIpxRipFilterRowStatus
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
snIpxRipFilterId OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The filter ID for a filter entry."
|
||
|
::= { snIpxRipFilterEntry 1 }
|
||
|
|
||
|
snIpxRipFilterAction OBJECT-TYPE
|
||
|
SYNTAX Action
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Action to take if the ipx packet match
|
||
|
with this filter."
|
||
|
::= { snIpxRipFilterEntry 2 }
|
||
|
|
||
|
snIpxRipFilterNet OBJECT-TYPE
|
||
|
SYNTAX NetNumber
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX RIP Filter Network number."
|
||
|
::= { snIpxRipFilterEntry 3 }
|
||
|
|
||
|
snIpxRipFilterMask OBJECT-TYPE
|
||
|
SYNTAX NetNumber
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX RIP Filter Network/Subnet Mask."
|
||
|
::= { snIpxRipFilterEntry 4 }
|
||
|
|
||
|
|
||
|
snIpxRipFilterRowStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
invalid(1),
|
||
|
valid(2),
|
||
|
delete(3),
|
||
|
create(4),
|
||
|
modify(5)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to create and
|
||
|
delete row in the table and control
|
||
|
if they are used. The values
|
||
|
that can be written are:
|
||
|
delete(3)...deletes the row
|
||
|
create(4)...creates a new row
|
||
|
modify(5)...modifies an exsisting row
|
||
|
|
||
|
If the row exists, then a SET with
|
||
|
value of create(4) returns error
|
||
|
'badValue'. Deleted rows go away
|
||
|
immediately. The following values
|
||
|
can be returned on reads:
|
||
|
noSuch(0)...no such row
|
||
|
invalid(1)...Setting it to 'invalid' has the effect of
|
||
|
rendering it inoperative..
|
||
|
valid(2)....the row exists and is valid"
|
||
|
::= { snIpxRipFilterEntry 5 }
|
||
|
|
||
|
|
||
|
|
||
|
-- IPX SAP Filter table
|
||
|
|
||
|
snIpxSapFilterTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SnIpxSapFilterEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX SAP Filter table."
|
||
|
::= { snIpxSapFilter 1 }
|
||
|
|
||
|
snIpxSapFilterEntry OBJECT-TYPE
|
||
|
SYNTAX SnIpxSapFilterEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the IPX SAP Filter table."
|
||
|
INDEX { snIpxSapFilterId }
|
||
|
::= { snIpxSapFilterTable 1 }
|
||
|
|
||
|
SnIpxSapFilterEntry ::= SEQUENCE {
|
||
|
snIpxSapFilterId
|
||
|
Integer32,
|
||
|
snIpxSapFilterAction
|
||
|
Action,
|
||
|
snIpxSapFilterType
|
||
|
Integer32,
|
||
|
snIpxSapFilterName
|
||
|
OCTET STRING,
|
||
|
snIpxSapFilterRowStatus
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
snIpxSapFilterId OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The filter ID for a filter entry."
|
||
|
::= { snIpxSapFilterEntry 1 }
|
||
|
|
||
|
snIpxSapFilterAction OBJECT-TYPE
|
||
|
SYNTAX Action
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Action to take if the ipx packet match
|
||
|
with this filter."
|
||
|
::= { snIpxSapFilterEntry 2 }
|
||
|
|
||
|
snIpxSapFilterType OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX SAP Filter type to be matched."
|
||
|
::= { snIpxSapFilterEntry 3 }
|
||
|
|
||
|
snIpxSapFilterName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING(SIZE(0..47))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX SAP Filter Name."
|
||
|
::= { snIpxSapFilterEntry 4 }
|
||
|
|
||
|
|
||
|
snIpxSapFilterRowStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
invalid(1),
|
||
|
valid(2),
|
||
|
delete(3),
|
||
|
create(4),
|
||
|
modify(5)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to create and
|
||
|
delete row in the table and control
|
||
|
if they are used. The values
|
||
|
that can be written are:
|
||
|
delete(3)...deletes the row
|
||
|
create(4)...creates a new row
|
||
|
modify(5)...modifies an exsisting row
|
||
|
|
||
|
If the row exists, then a SET with
|
||
|
value of create(4) returns error
|
||
|
'badValue'. Deleted rows go away
|
||
|
immediately. The following values
|
||
|
can be returned on reads:
|
||
|
noSuch(0)...no such row
|
||
|
invalid(1)...Setting it to 'invalid' has the effect of
|
||
|
rendering it inoperative..
|
||
|
valid(2)....the row exists and is valid"
|
||
|
::= { snIpxSapFilterEntry 5 }
|
||
|
|
||
|
|
||
|
-- IPX IF Forward Access table
|
||
|
|
||
|
snIpxIfFwdAccessTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SnIpxIfFwdAccessEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX IF Forward Access table."
|
||
|
::= { snIpxIfFwdAccess 1 }
|
||
|
|
||
|
snIpxIfFwdAccessEntry OBJECT-TYPE
|
||
|
SYNTAX SnIpxIfFwdAccessEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the IPX Forward Access table."
|
||
|
INDEX { snIpxIfFwdAccessPort, snIpxIfFwdAccessDir }
|
||
|
::= { snIpxIfFwdAccessTable 1 }
|
||
|
|
||
|
SnIpxIfFwdAccessEntry ::= SEQUENCE {
|
||
|
snIpxIfFwdAccessPort
|
||
|
Integer32,
|
||
|
snIpxIfFwdAccessDir
|
||
|
INTEGER,
|
||
|
snIpxIfFwdAccessFilterList
|
||
|
OCTET STRING,
|
||
|
snIpxIfFwdAccessRowStatus
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
snIpxIfFwdAccessPort OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The IPX interface to which the Forward Filter applies."
|
||
|
::= { snIpxIfFwdAccessEntry 1 }
|
||
|
|
||
|
snIpxIfFwdAccessDir OBJECT-TYPE
|
||
|
SYNTAX INTEGER { in(1), out(2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The access direction of incoming packet filter
|
||
|
or outgoing packet filter."
|
||
|
::= { snIpxIfFwdAccessEntry 2 }
|
||
|
|
||
|
snIpxIfFwdAccessFilterList OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING(SIZE(1..32))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An IPX IF Forward Filter List."
|
||
|
::= { snIpxIfFwdAccessEntry 3 }
|
||
|
|
||
|
|
||
|
snIpxIfFwdAccessRowStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
invalid(1),
|
||
|
valid(2),
|
||
|
delete(3),
|
||
|
create(4),
|
||
|
modify(5)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to create and
|
||
|
delete row in the table and control
|
||
|
if they are used. The values
|
||
|
that can be written are:
|
||
|
delete(3)...deletes the row
|
||
|
create(4)...creates a new row
|
||
|
modify(5)...modifies an exsisting row
|
||
|
|
||
|
If the row exists, then a SET with
|
||
|
value of create(4) returns error
|
||
|
'badValue'. Deleted rows go away
|
||
|
immediately. The following values
|
||
|
can be returned on reads:
|
||
|
noSuch(0)...no such row
|
||
|
invalid(1)...Setting it to 'invalid' has the effect of
|
||
|
rendering it inoperative..
|
||
|
valid(2)....the row exists and is valid"
|
||
|
::= { snIpxIfFwdAccessEntry 4 }
|
||
|
|
||
|
|
||
|
|
||
|
-- IPX IF RIP Access table
|
||
|
|
||
|
snIpxIfRipAccessTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SnIpxIfRipAccessEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX IF RIP Access table."
|
||
|
::= { snIpxIfRipAccess 1 }
|
||
|
|
||
|
snIpxIfRipAccessEntry OBJECT-TYPE
|
||
|
SYNTAX SnIpxIfRipAccessEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the IPX Forward Access table."
|
||
|
INDEX { snIpxIfRipAccessPort, snIpxIfRipAccessDir }
|
||
|
::= { snIpxIfRipAccessTable 1 }
|
||
|
|
||
|
SnIpxIfRipAccessEntry ::= SEQUENCE {
|
||
|
snIpxIfRipAccessPort
|
||
|
Integer32,
|
||
|
snIpxIfRipAccessDir
|
||
|
INTEGER,
|
||
|
snIpxIfRipAccessFilterList
|
||
|
OCTET STRING,
|
||
|
snIpxIfRipAccessRowStatus
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
snIpxIfRipAccessPort OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The IPX interface to which the RIP Filter applies."
|
||
|
::= { snIpxIfRipAccessEntry 1 }
|
||
|
|
||
|
snIpxIfRipAccessDir OBJECT-TYPE
|
||
|
SYNTAX INTEGER { in(1), out(2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The access direction of incoming packet filter
|
||
|
or outgoing packet filter."
|
||
|
::= { snIpxIfRipAccessEntry 2 }
|
||
|
|
||
|
snIpxIfRipAccessFilterList OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING(SIZE(1..32))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An IPX IF RIP Access Filter List."
|
||
|
::= { snIpxIfRipAccessEntry 3 }
|
||
|
|
||
|
|
||
|
snIpxIfRipAccessRowStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
invalid(1),
|
||
|
valid(2),
|
||
|
delete(3),
|
||
|
create(4),
|
||
|
modify(5)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to create and
|
||
|
delete row in the table and control
|
||
|
if they are used. The values
|
||
|
that can be written are:
|
||
|
delete(3)...deletes the row
|
||
|
create(4)...creates a new row
|
||
|
modify(5)...modifies an exsisting row
|
||
|
|
||
|
If the row exists, then a SET with
|
||
|
value of create(4) returns error
|
||
|
'badValue'. Deleted rows go away
|
||
|
immediately. The following values
|
||
|
can be returned on reads:
|
||
|
noSuch(0)...no such row
|
||
|
invalid(1)...Setting it to 'invalid' has the effect of
|
||
|
rendering it inoperative..
|
||
|
valid(2)....the row exists and is valid"
|
||
|
::= { snIpxIfRipAccessEntry 4 }
|
||
|
|
||
|
|
||
|
-- IPX IF SAP Access table
|
||
|
|
||
|
snIpxIfSapAccessTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SnIpxIfSapAccessEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX IF RIP Access table."
|
||
|
::= { snIpxIfSapAccess 1 }
|
||
|
|
||
|
snIpxIfSapAccessEntry OBJECT-TYPE
|
||
|
SYNTAX SnIpxIfSapAccessEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the IPX Forward Access table."
|
||
|
INDEX { snIpxIfSapAccessPort, snIpxIfSapAccessDir }
|
||
|
::= { snIpxIfSapAccessTable 1 }
|
||
|
|
||
|
SnIpxIfSapAccessEntry ::= SEQUENCE {
|
||
|
snIpxIfSapAccessPort
|
||
|
Integer32,
|
||
|
snIpxIfSapAccessDir
|
||
|
INTEGER,
|
||
|
snIpxIfSapAccessFilterList
|
||
|
OCTET STRING,
|
||
|
snIpxIfSapAccessRowStatus
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
snIpxIfSapAccessPort OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The IPX interface to which the SAP Filter applies."
|
||
|
::= { snIpxIfSapAccessEntry 1 }
|
||
|
|
||
|
snIpxIfSapAccessDir OBJECT-TYPE
|
||
|
SYNTAX INTEGER { in(1), out(2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The access direction of incoming packet filter
|
||
|
or outgoing packet filter."
|
||
|
::= { snIpxIfSapAccessEntry 2 }
|
||
|
|
||
|
snIpxIfSapAccessFilterList OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING(SIZE(1..32))
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An IPX IF SAP Access Filter List."
|
||
|
::= { snIpxIfSapAccessEntry 3 }
|
||
|
|
||
|
|
||
|
snIpxIfSapAccessRowStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
invalid(1),
|
||
|
valid(2),
|
||
|
delete(3),
|
||
|
create(4),
|
||
|
modify(5)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to create and
|
||
|
delete row in the table and control
|
||
|
if they are used. The values
|
||
|
that can be written are:
|
||
|
delete(3)...deletes the row
|
||
|
create(4)...creates a new row
|
||
|
modify(5)...modifies an exsisting row
|
||
|
|
||
|
If the row exists, then a SET with
|
||
|
value of create(4) returns error
|
||
|
'badValue'. Deleted rows go away
|
||
|
immediately. The following values
|
||
|
can be returned on reads:
|
||
|
noSuch(0)...no such row
|
||
|
invalid(1)...Setting it to 'invalid' has the effect of
|
||
|
rendering it inoperative..
|
||
|
valid(2)....the row exists and is valid"
|
||
|
::= { snIpxIfSapAccessEntry 4 }
|
||
|
|
||
|
|
||
|
-- ipx interface address table
|
||
|
|
||
|
snIpxPortAddrTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SnIpxPortAddrEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX port address table."
|
||
|
::= { snIpxPortAddr 1 }
|
||
|
|
||
|
snIpxPortAddrEntry OBJECT-TYPE
|
||
|
SYNTAX SnIpxPortAddrEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the IPX Port Address table."
|
||
|
INDEX { snIpxPortAddrPort, snIpxPortAddrEncap }
|
||
|
::= { snIpxPortAddrTable 1 }
|
||
|
|
||
|
SnIpxPortAddrEntry ::= SEQUENCE {
|
||
|
snIpxPortAddrPort
|
||
|
PortIndex,
|
||
|
snIpxPortAddrEncap
|
||
|
INTEGER,
|
||
|
snIpxPortAddrNetNum
|
||
|
NetNumber,
|
||
|
snIpxPortAddrRowStatus
|
||
|
INTEGER,
|
||
|
snIpxPortAddrNetBiosFilterMode
|
||
|
RtrStatus
|
||
|
}
|
||
|
|
||
|
|
||
|
snIpxPortAddrPort OBJECT-TYPE
|
||
|
SYNTAX PortIndex
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The port index for port address entry."
|
||
|
::= { snIpxPortAddrEntry 1 }
|
||
|
|
||
|
snIpxPortAddrEncap OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
ethernet8022(1),
|
||
|
ethernet8023(2),
|
||
|
ethernetII(3),
|
||
|
ethernetSnap(4)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The IPX encapsulation type.
|
||
|
ethernet8022(1), ethernet8023(2),
|
||
|
ethernetII(3), ethernetSnap(4)
|
||
|
Note: Each Network Number can be assigned with one unique Frame type; Otherwise,
|
||
|
a SNMP-SET error will be returned."
|
||
|
::= { snIpxPortAddrEntry 2 }
|
||
|
|
||
|
snIpxPortAddrNetNum OBJECT-TYPE
|
||
|
SYNTAX NetNumber
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An unique Network number for the IPX interface port."
|
||
|
::= { snIpxPortAddrEntry 3 }
|
||
|
|
||
|
snIpxPortAddrRowStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
invalid(1),
|
||
|
valid(2),
|
||
|
delete(3),
|
||
|
create(4),
|
||
|
modify(5)
|
||
|
}
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to create and
|
||
|
delete row in the table and control
|
||
|
if they are used. The values
|
||
|
that can be written are:
|
||
|
delete(3)...deletes the row
|
||
|
create(4)...creates a new row
|
||
|
modify(5)...modifies an exsisting row
|
||
|
|
||
|
If the row exists, then a SET with
|
||
|
value of create(4) returns error
|
||
|
'badValue'. Deleted rows go away
|
||
|
immediately. The following values
|
||
|
can be returned on reads:
|
||
|
noSuch(0)...no such row
|
||
|
invalid(1)...Setting it to 'invalid' has the effect of
|
||
|
rendering it inoperative..
|
||
|
valid(2)....the row exists and is valid"
|
||
|
::= { snIpxPortAddrEntry 4 }
|
||
|
|
||
|
snIpxPortAddrNetBiosFilterMode OBJECT-TYPE
|
||
|
SYNTAX RtrStatus
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enabled/Disabled NetBios Filter Mode status per Port Address entry."
|
||
|
::= { snIpxPortAddrEntry 5 }
|
||
|
|
||
|
|
||
|
-- ipx port counters table
|
||
|
|
||
|
snIpxPortCountersTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF SnIpxPortCountersEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX port Counters table."
|
||
|
::= { snIpxPortCounters 1 }
|
||
|
|
||
|
snIpxPortCountersEntry OBJECT-TYPE
|
||
|
SYNTAX SnIpxPortCountersEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An entry in the IPX Port Counters table."
|
||
|
INDEX { snIpxPortCountersPort }
|
||
|
::= { snIpxPortCountersTable 1 }
|
||
|
|
||
|
SnIpxPortCountersEntry ::= SEQUENCE {
|
||
|
snIpxPortCountersPort
|
||
|
PortIndex,
|
||
|
snIpxPortCountersRcvPktsCnt
|
||
|
Counter32,
|
||
|
snIpxPortCountersTxPktsCnt
|
||
|
Counter32,
|
||
|
snIpxPortCountersFwdPktsCnt
|
||
|
Counter32,
|
||
|
snIpxPortCountersRcvDropPktsCnt
|
||
|
Counter32,
|
||
|
snIpxPortCountersTxDropPktsCnt
|
||
|
Counter32,
|
||
|
snIpxPortCountersRcvFiltPktsCnt
|
||
|
Counter32,
|
||
|
snIpxPortCountersTxFiltPktsCnt
|
||
|
Counter32
|
||
|
}
|
||
|
|
||
|
|
||
|
snIpxPortCountersPort OBJECT-TYPE
|
||
|
SYNTAX PortIndex
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The port index for port Counters entry."
|
||
|
::= { snIpxPortCountersEntry 1 }
|
||
|
|
||
|
snIpxPortCountersRcvPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX incoming packets counter for the interface."
|
||
|
::= { snIpxPortCountersEntry 2 }
|
||
|
|
||
|
|
||
|
snIpxPortCountersTxPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX Outgoing packets counter for the interface."
|
||
|
::= { snIpxPortCountersEntry 3 }
|
||
|
|
||
|
|
||
|
snIpxPortCountersFwdPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX forwarding packets counter for the interface."
|
||
|
::= { snIpxPortCountersEntry 4 }
|
||
|
|
||
|
snIpxPortCountersRcvDropPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX receiving drop packets counter for the interface."
|
||
|
::= { snIpxPortCountersEntry 5 }
|
||
|
|
||
|
snIpxPortCountersTxDropPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX transmitting drop packets counter for the interface."
|
||
|
::= { snIpxPortCountersEntry 6 }
|
||
|
|
||
|
snIpxPortCountersRcvFiltPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX receiving filter packets counter for the interface."
|
||
|
::= { snIpxPortCountersEntry 7 }
|
||
|
|
||
|
snIpxPortCountersTxFiltPktsCnt OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"IPX transmitting filter packets counter for the interface."
|
||
|
::= { snIpxPortCountersEntry 8 }
|
||
|
|
||
|
|
||
|
|
||
|
END
|
||
|
|