mibs/MIBS/cambium/CAMBIUM-PTP250-MIB

1306 lines
40 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
CAMBIUM-PTP250-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, IpAddress,
enterprises
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
DisplayString
FROM SNMPv2-TC;
cambium MODULE-IDENTITY
LAST-UPDATED "201212070935Z"
ORGANIZATION "Cambium Networks"
CONTACT-INFO
"Post: Bill Jones
Cambium Networks Ltd.
Unit B2,
Linhay Business Park,
Eastern Road,
Ashburton,
Devon.
TQ13 7UP
United Kingdom
Phone: +44 (0) 1364 655 500
Email: bill.jones@cambiumnetworks.com"
DESCRIPTION
"MIB for PTP250"
REVISION "201212070935Z"
DESCRIPTION "PTP250-02-13:
sNMPTrapVersion moved into the sNMPTrapTable."
REVISION "201110181047Z"
DESCRIPTION "PTP250-02-00"
::= { enterprises 17713 }
-- Groups in cambium
ptp OBJECT IDENTIFIER ::= { cambium 1 }
ptmp OBJECT IDENTIFIER ::= { cambium 2 }
ptp250 OBJECT IDENTIFIER ::= { cambium 250 }
-- Groups in ptp250
configuration OBJECT IDENTIFIER ::= { ptp250 1 }
ethernet OBJECT IDENTIFIER ::= { ptp250 2 }
licence OBJECT IDENTIFIER ::= { ptp250 3 }
management OBJECT IDENTIFIER ::= { ptp250 4 }
phyStatus OBJECT IDENTIFIER ::= { ptp250 5 }
alarms OBJECT IDENTIFIER ::= { ptp250 6 }
smtp OBJECT IDENTIFIER ::= { ptp250 7 }
snmpControl OBJECT IDENTIFIER ::= { ptp250 8 }
ntp OBJECT IDENTIFIER ::= { ptp250 9 }
versions OBJECT IDENTIFIER ::= { ptp250 10 }
pubStats OBJECT IDENTIFIER ::= { ptp250 11 }
ptpGroups OBJECT IDENTIFIER ::= { ptp250 98 }
ptpTraps OBJECT IDENTIFIER ::= { ptp250 99 }
ptpTrapPrefix OBJECT IDENTIFIER ::= { ptpTraps 0 }
-- Compliance information
--
ptpCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the Cambium Networks PTP MIB"
MODULE -- this module
MANDATORY-GROUPS { configurationGroup
, ethernetGroup
, licenceGroup
, managementGroup
, phyStatusGroup
, alarmsGroup
, smtpGroup
, snmpControlGroup
, ntpGroup
, versionsGroup
, pubStatsGroup
, notificationsGroup
}
::= { ptp250 97 }
configurationGroup OBJECT-GROUP
OBJECTS { iPAddress
, subnetMask
, gatewayIPAddress
, masterSlaveMode
, maximumTransmitPower
, antennaGain
, cableLoss
, channelBandwidth
, remoteIPAddress
, remoteMACAddress
, linkName
, siteName
, band
, configuredModulationMode
, configuredRange
, channelSelection
, vlanTagging
, vlanId
, vlanPriority
, fixedModMode
, dualPayload
}
STATUS current
DESCRIPTION "The configuration object group."
::= { ptpGroups 5 }
ethernetGroup OBJECT-GROUP
OBJECTS { dataPortAutoNegotiation
, dataPortAutoNegAdvertisement
, dataPortStatus
, dataPortSpeedAndDuplex
}
STATUS current
DESCRIPTION "The ethernet object group."
::= { ptpGroups 6 }
licenceGroup OBJECT-GROUP
OBJECTS { regionCode
, productVariant
, productName
}
STATUS current
DESCRIPTION "The licence object group."
::= { ptpGroups 8 }
managementGroup OBJECT-GROUP
OBJECTS { installArmState
, tFTPServerIPAddress
, tFTPServerPortNumber
, tFTPSoftwareUpgradeFileName
, tFTPSoftwareUpgradeStatus
, tFTPSoftwareUpgradeStatusText
, tFTPSoftwareUpgradeStatusAdditionalText
}
STATUS current
DESCRIPTION "The management object group."
::= { ptpGroups 9 }
phyStatusGroup OBJECT-GROUP
OBJECTS { receivePower
, vectorError
, transmitPower
, linkLoss
, currentChannel
, extendedChannel
, receiveModulationMode
, transmitModulationMode
, currentFreqMHz
, extendedFreqMHz
, signalStrengthRatio
, searchState
, noiseFloor
, radarDetectChannel
, measuredRange
}
STATUS current
DESCRIPTION "The phyStatus object group."
::= { ptpGroups 12 }
alarmsGroup OBJECT-GROUP
OBJECTS { noWirelessChannelAvailable
}
STATUS current
DESCRIPTION "The alarms object group."
::= { ptpGroups 13 }
smtpGroup OBJECT-GROUP
OBJECTS { sMTPServerIPAddress
, sMTPServerPortNumber
, sMTPSourceEmailAddress
, sMTPDestinationEmailAddress
, sMTPEnabledMessages
}
STATUS current
DESCRIPTION "The smtp object group."
::= { ptpGroups 15 }
snmpControlGroup OBJECT-GROUP
OBJECTS { sNMPCommunityTableNumber
, sNMPTrapTableNumber
, sNMPEnabledTraps
, sNMPTrapIPAddress
, sNMPTrapPortNumber
, sNMPCommunityString
, sNMPCommunityAccess
, sNMPCommunityOid
, sNMPTrapCommunity
, sNMPTrapVersion
}
STATUS current
DESCRIPTION "The snmpControl object group."
::= { ptpGroups 16 }
ntpGroup OBJECT-GROUP
OBJECTS { nTPState
, nTPPollInterval
, nTPSync
, nTPLastSync
, systemClock
, timeZone
, nTPServerIp
, nTPServerPortNumber
}
STATUS current
DESCRIPTION "The ntp object group."
::= { ptpGroups 17 }
versionsGroup OBJECT-GROUP
OBJECTS { softwareVersion
, hardwareVersion
, bootVersion
}
STATUS current
DESCRIPTION "The versions object group."
::= { ptpGroups 19 }
pubStatsGroup OBJECT-GROUP
OBJECTS { receiveDataRate
, transmitDataRate
, aggregateDataRate
, wirelessLinkStatus
}
STATUS current
DESCRIPTION "The pubStats object group."
::= { ptpGroups 20 }
notificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { dataPortStatusTrap
, installArmStateTrap
, noWirelessChannelAvailableTrap
, linkStatusTrap
, radarDetectTrap
}
STATUS current
DESCRIPTION "The notifications group."
::= { ptpGroups 99 }
SNMPCommunityTableEntry ::=
SEQUENCE { sNMPCommunityTableIndex INTEGER
, sNMPCommunityString OCTET STRING
, sNMPCommunityAccess INTEGER
, sNMPCommunityOid OBJECT IDENTIFIER
}
sNMPCommunityTable OBJECT-TYPE
SYNTAX SEQUENCE OF SNMPCommunityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SNMP community string configuration table."
::= { snmpControl 2 }
sNMPCommunityTableEntry OBJECT-TYPE
SYNTAX SNMPCommunityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table SNMPCommunityTable"
INDEX { sNMPCommunityTableIndex }
::= { sNMPCommunityTable 1 }
SNMPTrapTableEntry ::=
SEQUENCE { sNMPTrapTableIndex INTEGER
, sNMPTrapIPAddress IpAddress
, sNMPTrapPortNumber INTEGER
, sNMPTrapCommunity OCTET STRING
, sNMPTrapVersion INTEGER
}
sNMPTrapTable OBJECT-TYPE
SYNTAX SEQUENCE OF SNMPTrapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SNMP trap configuration table."
::= { snmpControl 4 }
sNMPTrapTableEntry OBJECT-TYPE
SYNTAX SNMPTrapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table SNMPTrapTable"
INDEX { sNMPTrapTableIndex }
::= { sNMPTrapTable 1 }
-- Configuration group attribute definitions
--
iPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internet protocol (IP) address. This address is used by
the family of Internet protocols to uniquely identify
the unit on a network."
::= { configuration 1 }
subnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A subnet allows the flow of network traffic between
hosts to be segregated based on a network
configuration. By organizing hosts into
logical groups, subnetting can improve network
security and performance."
::= { configuration 2 }
gatewayIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address of a computer on the current network that
is currently acting as a network gateway. A gateway
acts as an entrance / exit to packets from / to
other networks."
::= { configuration 3 }
remoteMACAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the PTP wireless unit forming the other
end of the PTP link"
::= { configuration 4 }
masterSlaveMode OBJECT-TYPE
SYNTAX INTEGER {
slave(0),
master(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PTP wireless link operates using a master and slave
relationship"
::= { configuration 5 }
maximumTransmitPower OBJECT-TYPE
SYNTAX Integer32 (-15..27)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmit power the wireless unit is permitted to
use when establishing and maintaining the wireless
link"
::= { configuration 6 }
antennaGain OBJECT-TYPE
SYNTAX Integer32 (0..610)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Antenna Gain. Expressed in 10ths of dBi. NB: This
attribute is ignored for variants with an
integral antenna."
::= { configuration 7 }
cableLoss OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss in the cable between the ODU and the antenna.
Expressed in 10ths of dB. NB: This attribute is
ignored for variants with an integral antenna."
::= { configuration 8 }
channelBandwidth OBJECT-TYPE
SYNTAX INTEGER {
bw20MHz(0),
bw40MHz(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The selected bandwidth of the transmit and
receive radio channels"
::= { configuration 9 }
remoteIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP Address of the peer wireless unit"
::= { configuration 10 }
linkName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the PTP link allocated by the System
Administrator. Used to establish a
connection with the correct PTP wireless unit
at the other end of the link. NOTE: The link name MUST
be the same at both ends of the PTP link."
::= { configuration 11 }
siteName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field contains a user-provided description of the
site name together with any additional notes"
::= { configuration 12 }
configuredModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modBpskHalf(0),
modQpskHalf(1),
modQpskThreeQuarters(2),
mod16QamHalf(3),
mod16QamThreeQuarters(4),
mod64QamTwoThirds(5),
mod64QamThreeQuarters(6),
mod64QamFiveSixths(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fixed modulation mode or maximum adaptive modulation mode
to be used by the wireless link"
::= { configuration 13 }
band OBJECT-TYPE
SYNTAX INTEGER {
unset(0),
freq5400MHz(1),
freq5800MHz(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The frequency band to be
used by the wireless link"
::= { configuration 14 }
configuredRange OBJECT-TYPE
SYNTAX Integer32 (0..5400)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Configured distance between the two peer wireless units
expressed in hundredths of a kilometer."
::= { configuration 15 }
channelSelection OBJECT-TYPE
SYNTAX BITS {
channum100(0),
channum104(1),
channum108(2),
channum112(3),
channum116(4),
channum120(5),
channum124(6),
channum128(7),
channum132(8),
channum136(9),
channum140(10),
channum149(11),
channum153(12),
channum157(13),
channum161(14),
channum165(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The channels selected for use by the user. The
current channel will be selected from this list."
::= { configuration 16 }
vlanTagging OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether or not to use VLAN tagging for management."
::= { configuration 17 }
vlanId OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN ID for management."
::= { configuration 18 }
vlanPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VLAN priority for management."
::= { configuration 19 }
fixedModMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If disabled, allows automatic modulation mode selection."
::= { configuration 22 }
dualPayload OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If enabled, allows dual payload modulation modes to be selected."
::= { configuration 23 }
-- Ethernet group attribute definitions
--
dataPortAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This controls whether the local Ethernet interface
configuration is automatically negotiated
or forced."
::= { ethernet 1 }
dataPortAutoNegAdvertisement OBJECT-TYPE
SYNTAX BITS {
negInvalid(0),
neg10MbpsHalfDuplex(1),
neg10MbpsFullDuplex(2),
neg100MbpsHalfDuplex(3),
neg100MbpsFullDuplex(4),
neg1000MbpsFullDuplex(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This sets the different Ethernet configurations that
will be advertised during auto negotiation."
::= { ethernet 2 }
dataPortStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
up(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the Ethernet link. NB: a change of
state may generate an SNMP trap and/or SMTP email
alert"
::= { ethernet 3 }
dataPortSpeedAndDuplex OBJECT-TYPE
SYNTAX INTEGER {
speed1000MbpsFullDuplex(0),
speed100MbpsFullDuplex(1),
speed100MbpsHalfDuplex(2),
speed10MbpsFullDuplex(3),
speed10MbpsHalfDuplex(4),
speedUnknown6(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed and duplex of the Ethernet link"
::= { ethernet 4 }
-- Licence group attribute definitions
--
regionCode OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The region code prohibits the wireless unit from
operating outside the regulated limits.
NB: a change of state may generate an SNMP trap
and/or SMTP email alert"
::= { licence 1 }
productVariant OBJECT-TYPE
SYNTAX INTEGER {
ptpXX400Full(0),
ptpXX400Deprecated1(1),
ptpXX400Deprecated2(2),
ptpXX400Lite(3),
spare1(4),
ptpXX300(5),
spare2(6),
spare3(7),
ptpXX500FullDeprecated(8),
ptpXX500LiteDeprecated(9),
ptpXX500(10),
ptpXX600Lite(11),
ptpXX600Full(12),
spare5(13),
spare6(14),
ptp800(15),
ptp250(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The product variant"
::= { licence 2 }
productName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the product variant"
::= { licence 3 }
-- Management group attribute definitions
--
installArmState OBJECT-TYPE
SYNTAX INTEGER {
disarmed(0),
armed(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the unit is being installed. NB: a change
of state may generate an SNMP trap and/or SMTP email
alert"
::= { management 1 }
tFTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP address of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 2 }
tFTPServerPortNumber OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 3 }
tFTPSoftwareUpgradeFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Filename of the Software Upgrade to be loaded from the
TFTP Server"
::= { management 4 }
tFTPSoftwareUpgradeStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
uploadinprogress(1),
uploadsuccessfulprogrammingFLASH(2),
upgradesuccessfulreboottorunthenewsoftwareimage(3),
upgradefailed(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the TFTP Software upgrade process"
::= { management 5 }
tFTPSoftwareUpgradeStatusText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Descriptive text describing the status of the TFTP
Software upgrade process, including any error
details"
::= { management 6 }
tFTPSoftwareUpgradeStatusAdditionalText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Any additional text describing the status of the TFTP
Software upgrade process, including any error
details"
::= { management 7 }
-- PhyStatus group attribute definitions
--
receivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive power expressed in tenths of a dBm"
::= { phyStatus 1 }
vectorError OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vector error measurement compares the received
signal's IQ modulation characteristics to an
ideal signal to determine the composite error
vector magnitude. The value represented by this
attribute is the average vector error over the
previous second expressed in tenths of a dB"
::= { phyStatus 2 }
transmitPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit power expressed in tenths of a dBm"
::= { phyStatus 3 }
linkLoss OBJECT-TYPE
SYNTAX Integer32 (-500..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wireless link loss expressed in tenths of a dB"
::= { phyStatus 5 }
currentChannel OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active channel"
::= { phyStatus 6 }
extendedChannel OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current extended channel in 40MHz mode"
::= { phyStatus 7 }
receiveModulationMode OBJECT-TYPE
SYNTAX INTEGER {
acquisition(0),
modBpskHalfSingle(1),
modQpskHalfSingle(2),
modQpskThreeQuartersSingle(3),
mod16QamHalfSingle(4),
mod16QamThreeQuartersSingle(5),
mod64QamTwoThirdsSingle(6),
mod64QamThreeQuartersSingle(7),
mod64QamFiveSixthsSingle(8),
modBpskHalfDual(9),
modQpskHalfDual(10),
modQpskThreeQuartersDual(11),
mod16QamHalfDual(12),
mod16QamThreeQuartersDual(13),
mod64QamTwoThirdsDual(14),
mod64QamThreeQuartersDual(15),
mod64QamFiveSixthsDual(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active receive modulation mode"
::= { phyStatus 8 }
transmitModulationMode OBJECT-TYPE
SYNTAX INTEGER {
acquisition(0),
modBpskHalfSingle(1),
modQpskHalfSingle(2),
modQpskThreeQuartersSingle(3),
mod16QamHalfSingle(4),
mod16QamThreeQuartersSingle(5),
mod64QamTwoThirdsSingle(6),
mod64QamThreeQuartersSingle(7),
mod64QamFiveSixthsSingle(8),
modBpskHalfDual(9),
modQpskHalfDual(10),
modQpskThreeQuartersDual(11),
mod16QamHalfDual(12),
mod16QamThreeQuartersDual(13),
mod64QamTwoThirdsDual(14),
mod64QamThreeQuartersDual(15),
mod64QamFiveSixthsDual(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active transmit modulation mode"
::= { phyStatus 9 }
currentFreqMHz OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current channel frequency expressed in integer MHz"
::= { phyStatus 11 }
extendedFreqMHz OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Extended channel frequency expressed in integer MHz"
::= { phyStatus 12 }
signalStrengthRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal strength ratio (Vertical / Horizontal) : the
number of dB larger the Vertical antenna input is
than the Horizontal antenna input expressed in
tenths of a dB"
::= { phyStatus 13 }
searchState OBJECT-TYPE
SYNTAX INTEGER {
up(0),
registering(1),
acquiring(2),
searching(3),
radarCAC(4),
initialising(5),
noChannels(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Search status of the wireless unit. 'Registering' means
that the unit has locked to an OFDM signal, and the
wireless link is up. 'Searching' means that no
wireless signal has been detected. 'Acquiring'
means that a wireless signal has been detected, but
the unit has not locked to an OFDM signal."
::= { phyStatus 14 }
noiseFloor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Noise floor expressed in tenths of a dBm"
::= { phyStatus 15 }
radarDetectChannel OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Channel on which Radar has been detected.
(Note that this variable is accessible-for-notify only)."
::= { phyStatus 16 }
measuredRange OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured distance between the two peer wireless units
expressed in tenths of Km."
::= { phyStatus 17 }
-- Alarms group attribute definitions
--
noWirelessChannelAvailable OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
noWirelessChannelAvailable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Spectrum Management was unable to locate a suitable
wireless channel to operate on"
::= { alarms 1 }
-- Smtp group attribute definitions
--
sMTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP address of the SMTP server"
::= { smtp 1 }
sMTPServerPortNumber OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port number of the SMTP server"
::= { smtp 2 }
sMTPSourceEmailAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 'from' email address used when constructing the
automatically generated e-mail message"
::= { smtp 3 }
sMTPDestinationEmailAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The 'to' email address used when constructing the
automatically generated e-mail message"
::= { smtp 4 }
sMTPEnabledMessages OBJECT-TYPE
SYNTAX BITS {
dataPortUpDown(0),
wirelessLinkUpDown(1),
coldStart(2),
radarDetect(3),
installArmState(4),
noChannelAvailable(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This controls which SMTP messages the unit will send"
::= { smtp 5 }
-- SnmpControl group attribute definitions
--
sNMPCommunityTableNumber OBJECT-TYPE
SYNTAX Integer32 (2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the sNMPCommunityTable."
::= { snmpControl 1 }
sNMPTrapTableNumber OBJECT-TYPE
SYNTAX Integer32 (2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the sNMPTrapTable."
::= { snmpControl 3 }
sNMPEnabledTraps OBJECT-TYPE
SYNTAX BITS {
dataPortUpDown(0),
wirelessLinkUpDown(1),
coldStart(2),
radarDetect(3),
installArmState(4),
noChannelAvailable(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This controls which SNMP Traps the unit will send"
::= { snmpControl 6 }
-- SNMPCommunityTable group attribute definitions
--
sNMPCommunityTableIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SNMP community value, used to index the SNMPCommunityTable."
::= { sNMPCommunityTableEntry 1 }
sNMPCommunityString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The community string for this entry"
::= { sNMPCommunityTableEntry 2 }
sNMPCommunityAccess OBJECT-TYPE
SYNTAX INTEGER {
readOnly(0),
readWrite(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether this community allows read-only or read-write access"
::= { sNMPCommunityTableEntry 3 }
sNMPCommunityOid OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OID at which the root of this community's subtree starts"
::= { sNMPCommunityTableEntry 4 }
-- SNMPTrapTable group attribute definitions
--
sNMPTrapTableIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SNMP trap value, used to index the SNMPTrapTable."
::= { sNMPTrapTableEntry 1 }
sNMPTrapIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address to which all SNMP Traps are sent."
::= { sNMPTrapTableEntry 2 }
sNMPTrapPortNumber OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Destination port for SNMP Traps (default=162). A value
of 0 will disable the trap receiver."
::= { sNMPTrapTableEntry 3 }
sNMPTrapCommunity OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The community string for this trap entry"
::= { sNMPTrapTableEntry 4 }
sNMPTrapVersion OBJECT-TYPE
SYNTAX INTEGER {
v1(0),
v2c(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP protocol version for this trap entry"
::= { sNMPTrapTableEntry 5 }
-- Ntp group attribute definitions
--
nTPState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NTP control state"
::= { ntp 1 }
nTPPollInterval OBJECT-TYPE
SYNTAX Integer32 (60..43200)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The NTP server polling interval"
::= { ntp 2 }
nTPSync OBJECT-TYPE
SYNTAX INTEGER {
noSync(0),
inSync(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If NTP Sync fails then check the server settings in the
Remote Management page, or disable NTP"
::= { ntp 3 }
nTPLastSync OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last NTP sync time"
::= { ntp 4 }
systemClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System clock presented as local time"
::= { ntp 5 }
timeZone OBJECT-TYPE
SYNTAX INTEGER {
gmtMinus1200(0),
gmtMinus1130(1),
gmtMinus1100(2),
gmtMinus1030(3),
gmtMinus1000(4),
gmtMinus0930(5),
gmtMinus0900(6),
gmtMinus0830(7),
gmtMinus0800(8),
gmtMinus0730(9),
gmtMinus0700(10),
gmtMinus0630(11),
gmtMinus0600(12),
gmtMinus0530(13),
gmtMinus0500(14),
gmtMinus0430(15),
gmtMinus0400(16),
gmtMinus0330(17),
gmtMinus0300(18),
gmtMinus0230(19),
gmtMinus0200(20),
gmtMinus0130(21),
gmtMinus0100(22),
gmtMinus0030(23),
gmtZero(24),
gmtPlus0030(25),
gmtPlus0100(26),
gmtPlus0130(27),
gmtPlus0200(28),
gmtPlus0230(29),
gmtPlus0300(30),
gmtPlus0330(31),
gmtPlus0400(32),
gmtPlus0430(33),
gmtPlus0500(34),
gmtPlus0530(35),
gmtPlus0600(36),
gmtPlus0630(37),
gmtPlus0700(38),
gmtPlus0730(39),
gmtPlus0800(40),
gmtPlus0830(41),
gmtPlus0900(42),
gmtPlus0930(43),
gmtPlus1000(44),
gmtPlus1030(45),
gmtPlus1100(46),
gmtPlus1130(47),
gmtPlus1200(48),
gmtPlus1230(49),
gmtPlus1300(50)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time zone offsets from Greenwich Mean Time (GMT)"
::= { ntp 6 }
nTPServerIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the NTP server IP address."
::= { ntp 7 }
nTPServerPortNumber OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port number of the NTP server"
::= { ntp 8 }
-- Versions group attribute definitions
--
softwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current software version"
::= { versions 1 }
hardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware platform version"
::= { versions 2 }
bootVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Boot code software version"
::= { versions 3 }
-- PubStats group attribute definitions
--
receiveDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(tenths of Mbps)"
::= { pubStats 1 }
transmitDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(tenths of Mbps)"
::= { pubStats 2 }
aggregateDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(tenths of Mbps)"
::= { pubStats 3 }
wirelessLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
up(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the wireless link"
::= { pubStats 4 }
-- Enterprise NOTIFICATION definitions
--
dataPortStatusTrap NOTIFICATION-TYPE
OBJECTS { dataPortStatus }
STATUS current
DESCRIPTION
"Status of the Ethernet link has changed."
::= { ptpTrapPrefix 1 }
installArmStateTrap NOTIFICATION-TYPE
OBJECTS { installArmState }
STATUS current
DESCRIPTION
"Unit install arm state has changed"
::= { ptpTrapPrefix 2 }
noWirelessChannelAvailableTrap NOTIFICATION-TYPE
OBJECTS { noWirelessChannelAvailable }
STATUS current
DESCRIPTION
"Wireless channel availability has changed"
::= { ptpTrapPrefix 3 }
linkStatusTrap NOTIFICATION-TYPE
OBJECTS { wirelessLinkStatus }
STATUS current
DESCRIPTION
"Wireless link status has changed"
::= { ptpTrapPrefix 4 }
radarDetectTrap NOTIFICATION-TYPE
OBJECTS { radarDetectChannel }
STATUS current
DESCRIPTION
"Radar has been detected on one or more channels"
::= { ptpTrapPrefix 5 }
END