mibs/MIBS/comware/HH3C-MPLSOAM-PS-MIB

302 lines
10 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- ==================================================================
-- Copyright (C) 2005 New H3C Tech. Co., Ltd. All rights reserved.
--
-- Description: MPLSOAM PS(protection switching) MIB
-- Reference:
-- Version: V1.0
-- History:
-- V1.0 2007-03-31 Created by LiXufu ID: 05023
-- ==================================================================
HH3C-MPLSOAM-PS-MIB DEFINITIONS ::= BEGIN
IMPORTS
hh3cCommon
FROM HH3C-OID-MIB
Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
TruthValue, RowStatus
FROM SNMPv2-TC;
hh3cMplsOamPs MODULE-IDENTITY
LAST-UPDATED "200703310000Z" -- March 31, 2007 at 00:00 GMT
ORGANIZATION
"New H3C Tech. Co., Ltd."
CONTACT-INFO
"Platform Team New H3C Tech. Co., Ltd.
Hai-Dian District Beijing P.R. China
http://www.h3c.com
Zip:100085
"
DESCRIPTION
"This MIB contains objects to configure mpls
protect-switch module."
::= { hh3cCommon 80 }
-- ==================================================================
--
-- ======================= definition begin =========================
--
-- ==================================================================
hh3cMplsOamPsScalarGroup OBJECT IDENTIFIER ::= { hh3cMplsOamPs 1 }
hh3cMplsOamPsTrapOpen OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether mpls protect-switch trap is globally enabled.
false: disable;
true: enable"
DEFVAL { false }
::= { hh3cMplsOamPsScalarGroup 1 }
hh3cMplsOamPsTable OBJECT IDENTIFIER ::= { hh3cMplsOamPs 2 }
hh3cMplsPsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hh3cMplsPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table specifies per-protection-group MPLS PS
capability and associated information."
::= { hh3cMplsOamPsTable 1 }
hh3cMplsPsEntry OBJECT-TYPE
SYNTAX Hh3cMplsPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table is created by an LSR for every
protection group capable of supporting mpls ps."
INDEX
{
hh3cMplsPsIndex
}
::= { hh3cMplsPsTable 1 }
Hh3cMplsPsEntry ::= SEQUENCE
{
hh3cMplsPsIndex Integer32,
hh3cMplsPsGroupID Integer32,
hh3cMplsPsWorkLspName OCTET STRING,
hh3cMplsPsProtectLspName OCTET STRING,
hh3cMplsPsRevertiveMode Integer32,
hh3cMplsPsWTR Integer32,
hh3cMplsPsHoldOff Integer32,
hh3cMplsPsSwitchCondition Integer32,
hh3cMplsPsWorkLspDetectState Integer32,
hh3cMplsPsWorkLspUpDownState Integer32,
hh3cMplsPsProtLspDetectState Integer32,
hh3cMplsPsProtLspUpDownState Integer32,
hh3cMplsPsSwitchResult Integer32,
hh3cMplsPsRowStatus RowStatus
}
hh3cMplsPsIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a unique index for an entry in the mplspsEntry."
::= { hh3cMplsPsEntry 1 }
hh3cMplsPsGroupID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is a unique group id for an entry in the mplspsEntry.
One protect-switch group is composed of one working static-lsp
and one protection static-lsp."
::= { hh3cMplsPsEntry 2 }
hh3cMplsPsWorkLspName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The name of the working static-lsp."
::= { hh3cMplsPsEntry 3 }
hh3cMplsPsProtectLspName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The name of the protection static-lsp."
::= { hh3cMplsPsEntry 4 }
hh3cMplsPsRevertiveMode OBJECT-TYPE
SYNTAX Integer32(1..2)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Revertive mode is a protection switching mode where revertive
action (switch back to the working LSP) is taken after the
working LSP is repaired. And switching does not occur in a
non-revertive mode.
1: revertive;
2: non-revertive;"
::= { hh3cMplsPsEntry 5 }
hh3cMplsPsWTR OBJECT-TYPE
SYNTAX Integer32
UNITS "30s"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Wait to Restore timer is only applicable for the revertive mode
and applies to a working LSP, it prevents reversion back to
select the working LSP until the Wait to Restore timer has
expired.
The default value is 12 minutes. step is 30s."
::= { hh3cMplsPsEntry 6 }
hh3cMplsPsHoldOff OBJECT-TYPE
SYNTAX Integer32
UNITS "100ms"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The time between declaration of signal degrade or signal fail,
and the initialization of the protection switching algorithm.
Step is 100ms, maximum is 10s."
::= { hh3cMplsPsEntry 7 }
hh3cMplsPsSwitchCondition OBJECT-TYPE
SYNTAX Integer32(1..9)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The current switch condition of the protection group.
1: clear, this command clears all of the externally
initiated switch commands listed below;
2: lockout of protection, fix the selector position on the
working LSP, Prevents the selector from switching to the
protection LSP when it is selecting the working LSP.
Switches the selector from the protection to the working LSP
when it is selecting the protection LSP;
3: forced protection, switches the selector from the working LSP
to the protection LSP (unless a higher priority switch
request (i.e., LoP) is in effect);
4: signal fail, for 1:1, Signal Fail (SF) is declared when the
source of the protection domain enters the Defect State by
receiving a BDI packet (from the return LSP or out of band).
5: manual switch for working-lsp, switches the selector from the
working LSP to the protection LSP (unless an equal or higher
priority switch request (i.e., LoP, FS, SF or MS) is in
effect);
6: manual switch for protection-lsp, switches the selector from
the protection LSP to the working LSP (unless an equal or
higher priority switch request (i.e., LoP, FS, SF or MS) is
in effect).
7: WTR-timer, a configurable timer which is used to delay before
reversion;
8: HoldOff-timer, the time between declaration of signal degrade
or signal fail, and the initialization of the protection
switching algorithm;
9: Others;
The pripority of the commands are:
clear > lockout of protection > force switch > manual switch for working
lsp = manual switch for protection lsp"
::= { hh3cMplsPsEntry 8 }
hh3cMplsPsWorkLspDetectState OBJECT-TYPE
SYNTAX Integer32(1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of working static-lsp state in one protection group,
whether it is in defect:
1: it is out of defect;
2: it enters defect."
::= { hh3cMplsPsEntry 9 }
hh3cMplsPsWorkLspUpDownState OBJECT-TYPE
SYNTAX Integer32(1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of working static-lsp state in one protection group,
whether it is up or down:
1: it is in up state;
2: it is in down state."
::= { hh3cMplsPsEntry 10 }
hh3cMplsPsProtLspDetectState OBJECT-TYPE
SYNTAX Integer32(1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of protection static-lsp state in one protection group,
whether it is in detection:
1: it is out of defect;
2: it enters defect."
::= { hh3cMplsPsEntry 11 }
hh3cMplsPsProtLspUpDownState OBJECT-TYPE
SYNTAX Integer32(1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of protection static-lsp state in one protection group,
whether it is up or down:
1: it is in up state;
2: it is in down state."
::= { hh3cMplsPsEntry 12 }
hh3cMplsPsSwitchResult OBJECT-TYPE
SYNTAX Integer32(1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Which tunnel is used to transfer the data stream.
1: working static-lsp;
2: protection static-lsp."
::= { hh3cMplsPsEntry 13 }
hh3cMplsPsRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is responsible for managing the creation,
deletion and modification of rows, which support active
status and CreatAndGo, destroy operation.
To create a new row, hh3cMplsPsGroupID, hh3cMplsPsWorkLspName,
hh3cMplsPsProtectLspName, hh3cMplsPsRevertiveMode, hh3cMplsPsWTR
and hh3cMplsPsHoldOff must be specified."
::= { hh3cMplsPsEntry 14 }
hh3cMplsOamPsNotifications OBJECT IDENTIFIER ::= { hh3cMplsOamPs 3 }
hh3cMplsPsSwitchPtoW NOTIFICATION-TYPE
OBJECTS
{
hh3cMplsPsWorkLspName,
hh3cMplsPsProtectLspName,
hh3cMplsPsSwitchResult
}
STATUS current
DESCRIPTION
"This notification is generated when switching from
protection-lsp to working-lsp occured."
::= { hh3cMplsOamPsNotifications 1 }
hh3cMplsPsSwitchWtoP NOTIFICATION-TYPE
OBJECTS
{
hh3cMplsPsWorkLspName,
hh3cMplsPsProtectLspName,
hh3cMplsPsSwitchResult
}
STATUS current
DESCRIPTION
"This notification is generated when switching from woking-lsp
to protection-lsp occured."
::= { hh3cMplsOamPsNotifications 2 }
END