62 lines
1.3 KiB
Plaintext
62 lines
1.3 KiB
Plaintext
|
DKT-GENERIC-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32,
|
||
|
Counter32 FROM SNMPv2-SMI
|
||
|
OBJECT-GROUP FROM SNMPv2-CONF
|
||
|
dkt FROM DKT-MIB;
|
||
|
|
||
|
genericMIB MODULE-IDENTITY
|
||
|
LAST-UPDATED "200812170000Z"
|
||
|
ORGANIZATION "DKT A/S"
|
||
|
CONTACT-INFO
|
||
|
"postal: DKT A/S
|
||
|
Fanoevej 6
|
||
|
DK-4060 Kirke Saaby
|
||
|
Denmark
|
||
|
|
||
|
email: info@dktcomega.com"
|
||
|
DESCRIPTION "DKT GENERIC MIB."
|
||
|
::= { dkt 10 }
|
||
|
|
||
|
hwVersion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..100))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Version string for the HW"
|
||
|
::= { genericMIB 1 }
|
||
|
|
||
|
swVersion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE(0..100))
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Version string for the SW"
|
||
|
::= { genericMIB 2 }
|
||
|
|
||
|
reboot OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS write-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Set to 1 to reboot the device"
|
||
|
::= { genericMIB 3 }
|
||
|
|
||
|
|
||
|
genericModuleGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
hwVersion,
|
||
|
swVersion,
|
||
|
reboot
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The objects are related to all DKT modules."
|
||
|
::= { genericMIB 4 }
|
||
|
|
||
|
END
|
||
|
|
||
|
|
||
|
|