-- File Name : EquipmentCommon_MIB.mib
|
||
|
-- Version : 1.01.00
|
||
|
-- Date : May 1, 2015
|
||
|
-- Author : DragonWave Inc.
|
||
|
|
||
|
EQUIPMENT-COMMON-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
|
||
|
Counter64, IpAddress, Integer32, TimeTicks, Counter32, Unsigned32
|
||
|
FROM SNMPv2-SMI
|
||
|
TEXTUAL-CONVENTION, DisplayString, DateAndTime,
|
||
|
TimeStamp
|
||
|
FROM SNMPv2-TC
|
||
|
equipmentCommon
|
||
|
FROM DWI-HARMONY-PRIVATE-MIB;
|
||
|
|
||
|
-- Not supported : Opaque
|
||
|
-- [RFC2578]
|
||
|
-- [RFC2579]
|
||
|
--
|
||
|
-- Module Identity
|
||
|
--
|
||
|
|
||
|
equipmentCommonMib MODULE-IDENTITY
|
||
|
LAST-UPDATED "200901210000Z"
|
||
|
ORGANIZATION
|
||
|
"DragonWave Inc."
|
||
|
CONTACT-INFO
|
||
|
""
|
||
|
DESCRIPTION
|
||
|
"This MIB Module defines a notification log mechanism and a current alarm list."
|
||
|
|
||
|
REVISION "200901210000Z"
|
||
|
DESCRIPTION
|
||
|
"Initial Revision"
|
||
|
|
||
|
REVISION "201501051615Z"
|
||
|
DESCRIPTION
|
||
|
"Corrected EquipmentAlarmActiveTable index order."
|
||
|
::= { equipmentCommon 100 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- History of MIB Changes
|
||
|
--
|
||
|
--
|
||
|
--
|
||
|
-- Textual conventions
|
||
|
--
|
||
|
|
||
|
EnableType ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enabled/Disabled"
|
||
|
SYNTAX INTEGER {
|
||
|
disabled (0),
|
||
|
enabled (1)
|
||
|
}
|
||
|
|
||
|
|
||
|
--
|
||
|
-- Node definitions
|
||
|
--
|
||
|
|
||
|
equipmentCommonObjects OBJECT IDENTIFIER ::= { equipmentCommon 1 }
|
||
|
equipmentConfigLog OBJECT IDENTIFIER ::= { equipmentCommonObjects 1 }
|
||
|
equipmentLog OBJECT IDENTIFIER ::= { equipmentCommonObjects 2 }
|
||
|
equipmentAlarmList OBJECT IDENTIFIER ::= { equipmentCommonObjects 3 }
|
||
|
equipmentSnmpTrap OBJECT IDENTIFIER ::= { equipmentCommonObjects 4 }
|
||
|
equipmentPseudoEventsObjects OBJECT IDENTIFIER ::= { equipmentCommon 2 }
|
||
|
equipmentMirrorObjects OBJECT IDENTIFIER ::= { equipmentCommon 3 }
|
||
|
|
||
|
--
|
||
|
-- Object definitions: configuration section
|
||
|
--
|
||
|
|
||
|
equipmentEventLogEntryLimit OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum number of notification entries that may be held
|
||
|
in EventLogTable."
|
||
|
DEFVAL { 4096 }
|
||
|
::= { equipmentConfigLog 1 }
|
||
|
|
||
|
--
|
||
|
-- Object definitions: event log section
|
||
|
--
|
||
|
|
||
|
equipmentEventLogLastEntry OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of equipmentEventLogIndex at the time of the last
|
||
|
creation of an entry in the equipmentEventLogTable."
|
||
|
::= { equipmentLog 1 }
|
||
|
|
||
|
--
|
||
|
-- Event Notification Log Table (inspired by RFC 3014)
|
||
|
--
|
||
|
|
||
|
equipmentEventLogTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF EquipmentEventLogEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A table of Notification log entries."
|
||
|
::= { equipmentLog 2 }
|
||
|
|
||
|
equipmentEventLogEntry OBJECT-TYPE
|
||
|
SYNTAX EquipmentEventLogEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A Notification log entry. Entries appear in this table
|
||
|
when Notifications occur. They are removed to make way
|
||
|
for new entries due to lack of resources or the values of
|
||
|
equipmentEventLogEntryLimit.If adding an entry would exceed
|
||
|
equipmentEventLogEntryLimit the oldest entry in that log SHOULD
|
||
|
be removed to make room for the new one."
|
||
|
INDEX { equipmentEventLogIndex }
|
||
|
::= { equipmentEventLogTable 1 }
|
||
|
|
||
|
EquipmentEventLogEntry ::= SEQUENCE {
|
||
|
equipmentEventLogIndex
|
||
|
Unsigned32,
|
||
|
equipmentEventLogTime
|
||
|
TimeStamp,
|
||
|
equipmentEventLogDateAndTime
|
||
|
DateAndTime,
|
||
|
equipmentEventLogNotificationID
|
||
|
OBJECT IDENTIFIER,
|
||
|
equipmentEventLogVariables
|
||
|
Unsigned32
|
||
|
}
|
||
|
|
||
|
equipmentEventLogIndex OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..4294967295)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A monotonically increasing integer for the sole purpose of
|
||
|
indexing entries within the log. When it reaches the
|
||
|
maximum value,the agent wraps the value back to 1.
|
||
|
This number should correspond to the number of notifications
|
||
|
sent by the agent."
|
||
|
::= { equipmentEventLogEntry 1 }
|
||
|
|
||
|
equipmentEventLogTime OBJECT-TYPE
|
||
|
SYNTAX TimeStamp
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of sysUpTime when the entry was placed in the log."
|
||
|
::= { equipmentEventLogEntry 2 }
|
||
|
|
||
|
equipmentEventLogDateAndTime OBJECT-TYPE
|
||
|
SYNTAX DateAndTime
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The local date and time when the entry was logged, useful when browsing the MIB."
|
||
|
::= { equipmentEventLogEntry 3 }
|
||
|
|
||
|
equipmentEventLogNotificationID OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The NOTIFICATION-TYPE object identifier of the Notification that
|
||
|
occurred."
|
||
|
::= { equipmentEventLogEntry 4 }
|
||
|
|
||
|
equipmentEventLogVariables OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of variables in equipmentEventLogVariableTable for this
|
||
|
logged notification."
|
||
|
::= { equipmentEventLogEntry 5 }
|
||
|
|
||
|
--
|
||
|
-- Event Log variable Table
|
||
|
--
|
||
|
|
||
|
equipmentEventLogVariableTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF EquipmentEventLogVariableEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A table of variables to go with Notification log entries."
|
||
|
::= { equipmentLog 3 }
|
||
|
|
||
|
equipmentEventLogVariableEntry OBJECT-TYPE
|
||
|
SYNTAX EquipmentEventLogVariableEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A Notification log entry variable.
|
||
|
|
||
|
Entries appear in this table when there are variables in
|
||
|
the varbind list of a Notification in equipmentEventLogTable."
|
||
|
INDEX { equipmentEventLogIndex,
|
||
|
equipmentEventLogVariableIndex }
|
||
|
::= { equipmentEventLogVariableTable 1 }
|
||
|
|
||
|
EquipmentEventLogVariableEntry ::= SEQUENCE {
|
||
|
equipmentEventLogVariableIndex
|
||
|
Unsigned32,
|
||
|
equipmentEventLogVariableID
|
||
|
OBJECT IDENTIFIER,
|
||
|
equipmentEventLogVariableValueType
|
||
|
INTEGER,
|
||
|
equipmentEventLogVariableCounter32Val
|
||
|
Counter32,
|
||
|
equipmentEventLogVariableUnsigned32Val
|
||
|
Unsigned32,
|
||
|
equipmentEventLogVariableTimeTicksVal
|
||
|
TimeTicks,
|
||
|
equipmentEventLogVariableInteger32Val
|
||
|
Integer32,
|
||
|
equipmentEventLogVariableOctetStringVal
|
||
|
OCTET STRING,
|
||
|
equipmentEventLogVariableIpAddressVal
|
||
|
IpAddress,
|
||
|
equipmentEventLogVariableOidVal
|
||
|
OBJECT IDENTIFIER,
|
||
|
equipmentEventLogVariableCounter64Val
|
||
|
Counter64
|
||
|
}
|
||
|
|
||
|
equipmentEventLogVariableIndex OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..4294967295)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A monotonically increasing integer, starting at 1 for a given
|
||
|
equipmentEventLogIndex, for indexing variables within the logged
|
||
|
Event Notification."
|
||
|
::= { equipmentEventLogVariableEntry 1 }
|
||
|
|
||
|
equipmentEventLogVariableID OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The variable's object identifier."
|
||
|
::= { equipmentEventLogVariableEntry 2 }
|
||
|
|
||
|
equipmentEventLogVariableValueType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
counter32 (1),
|
||
|
unsigned32 (2),
|
||
|
timeTicks (3),
|
||
|
integer32 (4),
|
||
|
ipAddress (5),
|
||
|
octetString (6),
|
||
|
objectId (7),
|
||
|
counter64 (8)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The type of the value. One and only one of the value
|
||
|
objects that follow must be instantiated, based on this type."
|
||
|
::= { equipmentEventLogVariableEntry 3 }
|
||
|
|
||
|
-- Not supported: opaque(9)
|
||
|
|
||
|
equipmentEventLogVariableCounter32Val OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value when equipmentEventLogVariableValueType is 'counter32'."
|
||
|
::= { equipmentEventLogVariableEntry 4 }
|
||
|
|
||
|
equipmentEventLogVariableUnsigned32Val OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value when equipmentEventLogVariableValueType is 'unsigned32'."
|
||
|
::= { equipmentEventLogVariableEntry 5 }
|
||
|
|
||
|
equipmentEventLogVariableTimeTicksVal OBJECT-TYPE
|
||
|
SYNTAX TimeTicks
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value when equipmentEventLogVariableValueType is 'timeTicks'."
|
||
|
::= { equipmentEventLogVariableEntry 6 }
|
||
|
|
||
|
equipmentEventLogVariableInteger32Val OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value when equipmentEventLogVariableValueType is 'integer32'."
|
||
|
::= { equipmentEventLogVariableEntry 7 }
|
||
|
|
||
|
equipmentEventLogVariableOctetStringVal OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value when equipmentEventLogVariableValueType is 'octetString'."
|
||
|
::= { equipmentEventLogVariableEntry 8 }
|
||
|
|
||
|
equipmentEventLogVariableIpAddressVal OBJECT-TYPE
|
||
|
SYNTAX IpAddress
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value when equipmentEventLogVariableValueType is 'ipAddress'.
|
||
|
Although this seems to be unfriendly for IPv6, we
|
||
|
have to recognize that there are a number of older
|
||
|
MIBs that do contain an IPv4 format address, known
|
||
|
as IpAddress.
|
||
|
|
||
|
IPv6 addresses are represented using TAddress or
|
||
|
InetAddress, and so the underlying datatype is
|
||
|
OCTET STRING, and their value would be stored in
|
||
|
the equipmentEventLogVariableOctetStringVal column."
|
||
|
::= { equipmentEventLogVariableEntry 9 }
|
||
|
|
||
|
equipmentEventLogVariableOidVal OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value when equipmentEventLogVariableValueType is 'objectId'."
|
||
|
::= { equipmentEventLogVariableEntry 10 }
|
||
|
|
||
|
equipmentEventLogVariableCounter64Val OBJECT-TYPE
|
||
|
SYNTAX Counter64
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value when equipmentEventLogVariableValueType is 'counter64'."
|
||
|
::= { equipmentEventLogVariableEntry 11 }
|
||
|
|
||
|
--
|
||
|
-- Opaque type not supported
|
||
|
--
|
||
|
-- equipmentEventLogVariableOpaqueVal OBJECT-TYPE
|
||
|
-- SYNTAX Opaque
|
||
|
-- MAX-ACCESS read-only
|
||
|
-- STATUS current
|
||
|
-- DESCRIPTION
|
||
|
-- "The value when equipmentEventLogVariableValueType is 'opaque'."
|
||
|
-- ::= { equipmentEventLogVariableEntry 12 }
|
||
|
--
|
||
|
-- Object definitions: active alarm list section
|
||
|
--
|
||
|
--
|
||
|
-- Active Alarm Table
|
||
|
--
|
||
|
|
||
|
equipmentAlarmActiveLastChanged OBJECT-TYPE
|
||
|
SYNTAX TimeTicks
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of sysUpTime at the time of the last
|
||
|
creation or deletion of an entry in the equipmentAlarmActiveTable.
|
||
|
Useful in case of polling (no traps mechanism used).
|
||
|
If the number of entries has been unchanged since the
|
||
|
last re-initialization, then this object contains a zero value."
|
||
|
::= { equipmentAlarmList 1 }
|
||
|
|
||
|
equipmentAlarmActiveRowCounter OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of active alarms row in the table."
|
||
|
::= { equipmentAlarmList 2 }
|
||
|
|
||
|
equipmentAlarmActiveTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF EquipmentAlarmActiveEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A table of Active Alarms entries."
|
||
|
::= { equipmentAlarmList 3 }
|
||
|
|
||
|
equipmentAlarmActiveEntry OBJECT-TYPE
|
||
|
SYNTAX EquipmentAlarmActiveEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Entries appear in this table when alarms are raised. They
|
||
|
are removed when the alarm is cleared."
|
||
|
INDEX { equipmentAlarmActiveIndex,
|
||
|
equipmentAlarmActiveTime }
|
||
|
::= { equipmentAlarmActiveTable 1 }
|
||
|
|
||
|
EquipmentAlarmActiveEntry ::= SEQUENCE {
|
||
|
equipmentAlarmActiveIndex
|
||
|
Unsigned32,
|
||
|
equipmentAlarmActiveTime
|
||
|
TimeStamp,
|
||
|
equipmentAlarmActiveDateAndTime
|
||
|
DateAndTime,
|
||
|
equipmentAlarmActiveName
|
||
|
DisplayString,
|
||
|
equipmentAlarmActiveID
|
||
|
Integer32,
|
||
|
equipmentAlarmActiveInstance
|
||
|
Unsigned32,
|
||
|
equipmentAlarmActiveTrapOID
|
||
|
OBJECT IDENTIFIER,
|
||
|
equipmentAlarmActiveSeverity
|
||
|
INTEGER,
|
||
|
equipmentAlarmActiveConditionId
|
||
|
DisplayString
|
||
|
}
|
||
|
|
||
|
equipmentAlarmActiveIndex OBJECT-TYPE
|
||
|
SYNTAX Unsigned32 (1..4294967295)
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A strictly monotonically increasing integer which
|
||
|
acts as the index of entries within the named alarm
|
||
|
list. It wraps back to 1 after it reaches its
|
||
|
maximum value."
|
||
|
::= { equipmentAlarmActiveEntry 1 }
|
||
|
|
||
|
equipmentAlarmActiveTime OBJECT-TYPE
|
||
|
SYNTAX TimeStamp
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of sysUpTime when the entry was placed in the list.
|
||
|
This object facilitates retrieving all instances of
|
||
|
alarms that have been raised or have changed state
|
||
|
since a given point in time."
|
||
|
::= { equipmentAlarmActiveEntry 2 }
|
||
|
|
||
|
equipmentAlarmActiveDateAndTime OBJECT-TYPE
|
||
|
SYNTAX DateAndTime
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The local date and time when the error occurred.
|
||
|
|
||
|
This object facilitates retrieving all instances of
|
||
|
alarms that have been raised or have changed state
|
||
|
since a given point in time.
|
||
|
|
||
|
Implementations MUST include the offset from UTC,
|
||
|
if available. Implementation in environments in which
|
||
|
the UTC offset is not available is NOT RECOMMENDED."
|
||
|
::= { equipmentAlarmActiveEntry 3 }
|
||
|
|
||
|
equipmentAlarmActiveName OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the active alarm name."
|
||
|
::= { equipmentAlarmActiveEntry 4 }
|
||
|
|
||
|
equipmentAlarmActiveID OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the active alarm ID which is the index to the alarm configuration table defined in product specific MIB."
|
||
|
::= { equipmentAlarmActiveEntry 5 }
|
||
|
|
||
|
equipmentAlarmActiveInstance OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
""
|
||
|
::= { equipmentAlarmActiveEntry 6 }
|
||
|
|
||
|
equipmentAlarmActiveTrapOID OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The MIB object identifier of the alarm (contained in an Alarm Notification
|
||
|
type object) that is occurring."
|
||
|
::= { equipmentAlarmActiveEntry 7 }
|
||
|
|
||
|
equipmentAlarmActiveSeverity OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
warning (1),
|
||
|
minor (2),
|
||
|
major (3),
|
||
|
critical (4)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object indicates the active alarm severity."
|
||
|
::= { equipmentAlarmActiveEntry 8 }
|
||
|
|
||
|
equipmentAlarmActiveConditionId OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
""
|
||
|
::= { equipmentAlarmActiveEntry 9 }
|
||
|
|
||
|
--
|
||
|
-- Opaque type not supported
|
||
|
--
|
||
|
-- equipmentAlarmActiveSourceOpaqueVal OBJECT-TYPE
|
||
|
-- SYNTAX Opaque
|
||
|
-- MAX-ACCESS read-only
|
||
|
-- STATUS current
|
||
|
-- DESCRIPTION
|
||
|
-- "The value when value type is 'opaque'.It is coded as follows:
|
||
|
-- code: OCTET STRING(SIZE(1)), fixed to 1 (structure identifier);
|
||
|
-- type: INTEGER, see equipmentEventLogVariableValueType values;
|
||
|
-- value: ASN.1 basic encoding rule"
|
||
|
-- ::= { equipmentAlarmActiveEntry 5 }
|
||
|
--
|
||
|
-- Object definitions: trap counter and timestamp
|
||
|
--
|
||
|
|
||
|
equipmentOutTrapsCounter OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The counter of the output traps.
|
||
|
It increases by one every time a new trap is sent to all the managers configured
|
||
|
in the relevant table. In this way its value is the number of notification events
|
||
|
occurred since the last agent reset and every manager that reads this value can understand
|
||
|
whether some event has been lost or not.
|
||
|
(Note that in general this counter differs from the RFC1213 snmpOutTraps, that counts the
|
||
|
number of Trap PDUs sent). When the logging mechanism is enabled, it corresponds to the index in the eventlog table"
|
||
|
::= { equipmentSnmpTrap 1 }
|
||
|
|
||
|
equipmentLastOutTrapTimeStamp OBJECT-TYPE
|
||
|
SYNTAX TimeStamp
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of sysUpTime when the last trap was sent."
|
||
|
::= { equipmentSnmpTrap 2 }
|
||
|
|
||
|
equipmentTrapInfo OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A string representing additional info that can be used as the varbind in trap. "
|
||
|
::= { equipmentSnmpTrap 3 }
|
||
|
|
||
|
--
|
||
|
-- Object definitions: pseudo-events support
|
||
|
--
|
||
|
|
||
|
equipmentConfChangeOid OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The OID of the last node changed. It is sent to the managers in order to
|
||
|
notify a configuration change."
|
||
|
::= { equipmentPseudoEventsObjects 1 }
|
||
|
|
||
|
equipmentConfChangeMode OBJECT-TYPE
|
||
|
SYNTAX EnableType
|
||
|
MAX-ACCESS read-write
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Enable/Disable of sending ConfChange Trap.
|
||
|
STORAGE: permanent."
|
||
|
DEFVAL { enabled }
|
||
|
::= { equipmentPseudoEventsObjects 2 }
|
||
|
|
||
|
equipmentConfChangeNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { equipmentConfChangeOid,
|
||
|
equipmentOutTrapsCounter }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Notification of configuration change."
|
||
|
::= { equipmentPseudoEventsObjects 3 }
|
||
|
|
||
|
--
|
||
|
-- Object definitions: mirror-traps support
|
||
|
--
|
||
|
|
||
|
equipmentMirrorFlag OBJECT-TYPE
|
||
|
SYNTAX Integer32 (0..65535)
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Fixed to 1=mirror trap"
|
||
|
::= { equipmentMirrorObjects 1 }
|
||
|
|
||
|
equipmentMirrorColdStart NOTIFICATION-TYPE
|
||
|
OBJECTS { equipmentMirrorFlag,
|
||
|
equipmentOutTrapsCounter }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A coldStart trap signifies that the SNMP entity,
|
||
|
supporting a notification originator application, is
|
||
|
reinitializing itself and that its configuration may
|
||
|
have been altered."
|
||
|
::= { equipmentMirrorObjects 2 }
|
||
|
END
|
||
|
|
||
|
|