mibs/MIBS/dragonwave/EQUIPMENT-COMMON-MIB

620 lines
18 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- File Name : EquipmentCommon_MIB.mib
-- Version : 1.01.00
-- Date : May 1, 2015
-- Author : DragonWave Inc.
EQUIPMENT-COMMON-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
Counter64, IpAddress, Integer32, TimeTicks, Counter32, Unsigned32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString, DateAndTime,
TimeStamp
FROM SNMPv2-TC
equipmentCommon
FROM DWI-HARMONY-PRIVATE-MIB;
-- Not supported : Opaque
-- [RFC2578]
-- [RFC2579]
--
-- Module Identity
--
equipmentCommonMib MODULE-IDENTITY
LAST-UPDATED "200901210000Z"
ORGANIZATION
"DragonWave Inc."
CONTACT-INFO
""
DESCRIPTION
"This MIB Module defines a notification log mechanism and a current alarm list."
REVISION "200901210000Z"
DESCRIPTION
"Initial Revision"
REVISION "201501051615Z"
DESCRIPTION
"Corrected EquipmentAlarmActiveTable index order."
::= { equipmentCommon 100 }
--
-- History of MIB Changes
--
--
--
-- Textual conventions
--
EnableType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enabled/Disabled"
SYNTAX INTEGER {
disabled (0),
enabled (1)
}
--
-- Node definitions
--
equipmentCommonObjects OBJECT IDENTIFIER ::= { equipmentCommon 1 }
equipmentConfigLog OBJECT IDENTIFIER ::= { equipmentCommonObjects 1 }
equipmentLog OBJECT IDENTIFIER ::= { equipmentCommonObjects 2 }
equipmentAlarmList OBJECT IDENTIFIER ::= { equipmentCommonObjects 3 }
equipmentSnmpTrap OBJECT IDENTIFIER ::= { equipmentCommonObjects 4 }
equipmentPseudoEventsObjects OBJECT IDENTIFIER ::= { equipmentCommon 2 }
equipmentMirrorObjects OBJECT IDENTIFIER ::= { equipmentCommon 3 }
--
-- Object definitions: configuration section
--
equipmentEventLogEntryLimit OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of notification entries that may be held
in EventLogTable."
DEFVAL { 4096 }
::= { equipmentConfigLog 1 }
--
-- Object definitions: event log section
--
equipmentEventLogLastEntry OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of equipmentEventLogIndex at the time of the last
creation of an entry in the equipmentEventLogTable."
::= { equipmentLog 1 }
--
-- Event Notification Log Table (inspired by RFC 3014)
--
equipmentEventLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF EquipmentEventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Notification log entries."
::= { equipmentLog 2 }
equipmentEventLogEntry OBJECT-TYPE
SYNTAX EquipmentEventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Notification log entry. Entries appear in this table
when Notifications occur. They are removed to make way
for new entries due to lack of resources or the values of
equipmentEventLogEntryLimit.If adding an entry would exceed
equipmentEventLogEntryLimit the oldest entry in that log SHOULD
be removed to make room for the new one."
INDEX { equipmentEventLogIndex }
::= { equipmentEventLogTable 1 }
EquipmentEventLogEntry ::= SEQUENCE {
equipmentEventLogIndex
Unsigned32,
equipmentEventLogTime
TimeStamp,
equipmentEventLogDateAndTime
DateAndTime,
equipmentEventLogNotificationID
OBJECT IDENTIFIER,
equipmentEventLogVariables
Unsigned32
}
equipmentEventLogIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A monotonically increasing integer for the sole purpose of
indexing entries within the log. When it reaches the
maximum value,the agent wraps the value back to 1.
This number should correspond to the number of notifications
sent by the agent."
::= { equipmentEventLogEntry 1 }
equipmentEventLogTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the entry was placed in the log."
::= { equipmentEventLogEntry 2 }
equipmentEventLogDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local date and time when the entry was logged, useful when browsing the MIB."
::= { equipmentEventLogEntry 3 }
equipmentEventLogNotificationID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The NOTIFICATION-TYPE object identifier of the Notification that
occurred."
::= { equipmentEventLogEntry 4 }
equipmentEventLogVariables OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of variables in equipmentEventLogVariableTable for this
logged notification."
::= { equipmentEventLogEntry 5 }
--
-- Event Log variable Table
--
equipmentEventLogVariableTable OBJECT-TYPE
SYNTAX SEQUENCE OF EquipmentEventLogVariableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of variables to go with Notification log entries."
::= { equipmentLog 3 }
equipmentEventLogVariableEntry OBJECT-TYPE
SYNTAX EquipmentEventLogVariableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Notification log entry variable.
Entries appear in this table when there are variables in
the varbind list of a Notification in equipmentEventLogTable."
INDEX { equipmentEventLogIndex,
equipmentEventLogVariableIndex }
::= { equipmentEventLogVariableTable 1 }
EquipmentEventLogVariableEntry ::= SEQUENCE {
equipmentEventLogVariableIndex
Unsigned32,
equipmentEventLogVariableID
OBJECT IDENTIFIER,
equipmentEventLogVariableValueType
INTEGER,
equipmentEventLogVariableCounter32Val
Counter32,
equipmentEventLogVariableUnsigned32Val
Unsigned32,
equipmentEventLogVariableTimeTicksVal
TimeTicks,
equipmentEventLogVariableInteger32Val
Integer32,
equipmentEventLogVariableOctetStringVal
OCTET STRING,
equipmentEventLogVariableIpAddressVal
IpAddress,
equipmentEventLogVariableOidVal
OBJECT IDENTIFIER,
equipmentEventLogVariableCounter64Val
Counter64
}
equipmentEventLogVariableIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A monotonically increasing integer, starting at 1 for a given
equipmentEventLogIndex, for indexing variables within the logged
Event Notification."
::= { equipmentEventLogVariableEntry 1 }
equipmentEventLogVariableID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The variable's object identifier."
::= { equipmentEventLogVariableEntry 2 }
equipmentEventLogVariableValueType OBJECT-TYPE
SYNTAX INTEGER {
counter32 (1),
unsigned32 (2),
timeTicks (3),
integer32 (4),
ipAddress (5),
octetString (6),
objectId (7),
counter64 (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the value. One and only one of the value
objects that follow must be instantiated, based on this type."
::= { equipmentEventLogVariableEntry 3 }
-- Not supported: opaque(9)
equipmentEventLogVariableCounter32Val OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value when equipmentEventLogVariableValueType is 'counter32'."
::= { equipmentEventLogVariableEntry 4 }
equipmentEventLogVariableUnsigned32Val OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value when equipmentEventLogVariableValueType is 'unsigned32'."
::= { equipmentEventLogVariableEntry 5 }
equipmentEventLogVariableTimeTicksVal OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value when equipmentEventLogVariableValueType is 'timeTicks'."
::= { equipmentEventLogVariableEntry 6 }
equipmentEventLogVariableInteger32Val OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value when equipmentEventLogVariableValueType is 'integer32'."
::= { equipmentEventLogVariableEntry 7 }
equipmentEventLogVariableOctetStringVal OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value when equipmentEventLogVariableValueType is 'octetString'."
::= { equipmentEventLogVariableEntry 8 }
equipmentEventLogVariableIpAddressVal OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value when equipmentEventLogVariableValueType is 'ipAddress'.
Although this seems to be unfriendly for IPv6, we
have to recognize that there are a number of older
MIBs that do contain an IPv4 format address, known
as IpAddress.
IPv6 addresses are represented using TAddress or
InetAddress, and so the underlying datatype is
OCTET STRING, and their value would be stored in
the equipmentEventLogVariableOctetStringVal column."
::= { equipmentEventLogVariableEntry 9 }
equipmentEventLogVariableOidVal OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value when equipmentEventLogVariableValueType is 'objectId'."
::= { equipmentEventLogVariableEntry 10 }
equipmentEventLogVariableCounter64Val OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value when equipmentEventLogVariableValueType is 'counter64'."
::= { equipmentEventLogVariableEntry 11 }
--
-- Opaque type not supported
--
-- equipmentEventLogVariableOpaqueVal OBJECT-TYPE
-- SYNTAX Opaque
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value when equipmentEventLogVariableValueType is 'opaque'."
-- ::= { equipmentEventLogVariableEntry 12 }
--
-- Object definitions: active alarm list section
--
--
-- Active Alarm Table
--
equipmentAlarmActiveLastChanged OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time of the last
creation or deletion of an entry in the equipmentAlarmActiveTable.
Useful in case of polling (no traps mechanism used).
If the number of entries has been unchanged since the
last re-initialization, then this object contains a zero value."
::= { equipmentAlarmList 1 }
equipmentAlarmActiveRowCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of active alarms row in the table."
::= { equipmentAlarmList 2 }
equipmentAlarmActiveTable OBJECT-TYPE
SYNTAX SEQUENCE OF EquipmentAlarmActiveEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Active Alarms entries."
::= { equipmentAlarmList 3 }
equipmentAlarmActiveEntry OBJECT-TYPE
SYNTAX EquipmentAlarmActiveEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries appear in this table when alarms are raised. They
are removed when the alarm is cleared."
INDEX { equipmentAlarmActiveIndex,
equipmentAlarmActiveTime }
::= { equipmentAlarmActiveTable 1 }
EquipmentAlarmActiveEntry ::= SEQUENCE {
equipmentAlarmActiveIndex
Unsigned32,
equipmentAlarmActiveTime
TimeStamp,
equipmentAlarmActiveDateAndTime
DateAndTime,
equipmentAlarmActiveName
DisplayString,
equipmentAlarmActiveID
Integer32,
equipmentAlarmActiveInstance
Unsigned32,
equipmentAlarmActiveTrapOID
OBJECT IDENTIFIER,
equipmentAlarmActiveSeverity
INTEGER,
equipmentAlarmActiveConditionId
DisplayString
}
equipmentAlarmActiveIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A strictly monotonically increasing integer which
acts as the index of entries within the named alarm
list. It wraps back to 1 after it reaches its
maximum value."
::= { equipmentAlarmActiveEntry 1 }
equipmentAlarmActiveTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of sysUpTime when the entry was placed in the list.
This object facilitates retrieving all instances of
alarms that have been raised or have changed state
since a given point in time."
::= { equipmentAlarmActiveEntry 2 }
equipmentAlarmActiveDateAndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local date and time when the error occurred.
This object facilitates retrieving all instances of
alarms that have been raised or have changed state
since a given point in time.
Implementations MUST include the offset from UTC,
if available. Implementation in environments in which
the UTC offset is not available is NOT RECOMMENDED."
::= { equipmentAlarmActiveEntry 3 }
equipmentAlarmActiveName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the active alarm name."
::= { equipmentAlarmActiveEntry 4 }
equipmentAlarmActiveID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the active alarm ID which is the index to the alarm configuration table defined in product specific MIB."
::= { equipmentAlarmActiveEntry 5 }
equipmentAlarmActiveInstance OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { equipmentAlarmActiveEntry 6 }
equipmentAlarmActiveTrapOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MIB object identifier of the alarm (contained in an Alarm Notification
type object) that is occurring."
::= { equipmentAlarmActiveEntry 7 }
equipmentAlarmActiveSeverity OBJECT-TYPE
SYNTAX INTEGER {
warning (1),
minor (2),
major (3),
critical (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the active alarm severity."
::= { equipmentAlarmActiveEntry 8 }
equipmentAlarmActiveConditionId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { equipmentAlarmActiveEntry 9 }
--
-- Opaque type not supported
--
-- equipmentAlarmActiveSourceOpaqueVal OBJECT-TYPE
-- SYNTAX Opaque
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The value when value type is 'opaque'.It is coded as follows:
-- code: OCTET STRING(SIZE(1)), fixed to 1 (structure identifier);
-- type: INTEGER, see equipmentEventLogVariableValueType values;
-- value: ASN.1 basic encoding rule"
-- ::= { equipmentAlarmActiveEntry 5 }
--
-- Object definitions: trap counter and timestamp
--
equipmentOutTrapsCounter OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter of the output traps.
It increases by one every time a new trap is sent to all the managers configured
in the relevant table. In this way its value is the number of notification events
occurred since the last agent reset and every manager that reads this value can understand
whether some event has been lost or not.
(Note that in general this counter differs from the RFC1213 snmpOutTraps, that counts the
number of Trap PDUs sent). When the logging mechanism is enabled, it corresponds to the index in the eventlog table"
::= { equipmentSnmpTrap 1 }
equipmentLastOutTrapTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the last trap was sent."
::= { equipmentSnmpTrap 2 }
equipmentTrapInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A string representing additional info that can be used as the varbind in trap. "
::= { equipmentSnmpTrap 3 }
--
-- Object definitions: pseudo-events support
--
equipmentConfChangeOid OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OID of the last node changed. It is sent to the managers in order to
notify a configuration change."
::= { equipmentPseudoEventsObjects 1 }
equipmentConfChangeMode OBJECT-TYPE
SYNTAX EnableType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable of sending ConfChange Trap.
STORAGE: permanent."
DEFVAL { enabled }
::= { equipmentPseudoEventsObjects 2 }
equipmentConfChangeNotification NOTIFICATION-TYPE
OBJECTS { equipmentConfChangeOid,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"Notification of configuration change."
::= { equipmentPseudoEventsObjects 3 }
--
-- Object definitions: mirror-traps support
--
equipmentMirrorFlag OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fixed to 1=mirror trap"
::= { equipmentMirrorObjects 1 }
equipmentMirrorColdStart NOTIFICATION-TYPE
OBJECTS { equipmentMirrorFlag,
equipmentOutTrapsCounter }
STATUS current
DESCRIPTION
"A coldStart trap signifies that the SNMP entity,
supporting a notification originator application, is
reinitializing itself and that its configuration may
have been altered."
::= { equipmentMirrorObjects 2 }
END