CT-CMMPHYS-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
-- ct-cmmphys-mib.txt
|
||
|
-- Revision: 01.00.00
|
||
|
-- Part Number:
|
||
|
-- Date: December 16, 1998
|
||
|
|
||
|
-- Cabletron Systems, Inc.
|
||
|
-- 35 Industrial Way, P.O. Box 5005
|
||
|
-- Rochester, NH 03867-0505
|
||
|
-- (603) 332-9400
|
||
|
-- support@ctron.com
|
||
|
|
||
|
-- This module provides an enterprise-specific CMM container MIB.
|
||
|
--
|
||
|
-- This module will be extended, as needed.
|
||
|
--
|
||
|
|
||
|
-- Goals and Philosophy
|
||
|
--
|
||
|
-- The purpose of this MIB is to provide a central repository of all
|
||
|
-- information pertaining to the configuration, operation, status,
|
||
|
-- and health of a CMM board and its CMM modules. The goal of these
|
||
|
-- values is to facilitate troubleshooting problems at the level of
|
||
|
-- a CMM board or CMM module. The intended audience for this
|
||
|
-- information includes customers, field engineers, and developers.
|
||
|
|
||
|
-- Cabletron Systems reserves the right to make changes in
|
||
|
-- specification and other information contained in this document
|
||
|
-- without prior notice. The reader should consult Cabletron Systems
|
||
|
-- to determine whether any such changes have been made.
|
||
|
--
|
||
|
-- In no event shall Cabletron Systems be liable for any incidental,
|
||
|
-- indirect, special, or consequential damages whatsoever (including
|
||
|
-- but not limited to lost profits) arising out of or related to this
|
||
|
-- document or the information contained in it, even if Cabletron
|
||
|
-- Systems has been advised of, known, or should have known, the
|
||
|
-- possibility of such damages.
|
||
|
--
|
||
|
-- Cabletron grants vendors, end-users, and other interested parties
|
||
|
-- a non-exclusive license to use this Specification in connection
|
||
|
-- with the management of Cabletron products.
|
||
|
|
||
|
-- Copyright December 98 Cabletron Systems
|
||
|
|
||
|
IMPORTS
|
||
|
OBJECT-TYPE
|
||
|
FROM RFC-1212
|
||
|
DisplayString,ifIndex
|
||
|
FROM RFC1213-MIB
|
||
|
IpAddress,Counter,Gauge
|
||
|
FROM RFC1155-SMI
|
||
|
ctCMM
|
||
|
FROM CTRON-MIB-NAMES
|
||
|
mBusBoardID
|
||
|
FROM CT-HSIMPHYS-MIB;
|
||
|
|
||
|
--=============== Group Definitions ===================
|
||
|
|
||
|
-- This is just a dummy value to get this to compile correctly for now.
|
||
|
|
||
|
cmmModemInfo OBJECT IDENTIFIER ::= { ctCMM 1 }
|
||
|
|
||
|
--================================================================
|
||
|
|
||
|
-- This MIB module uses the extended OBJECT-TYPE macro as defined
|
||
|
-- RFC 1212
|
||
|
|
||
|
--================= CMM Board-Level Info ===================
|
||
|
cmmBoardTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CmmBoardEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of CMM boards present in this unit."
|
||
|
::= { cmmModemInfo 1 }
|
||
|
|
||
|
cmmBoardEntry OBJECT-TYPE
|
||
|
SYNTAX CmmBoardEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A CMM board present in this unit."
|
||
|
INDEX { mBusBoardID }
|
||
|
::= { cmmBoardTable 1 }
|
||
|
|
||
|
|
||
|
CmmBoardEntry ::=
|
||
|
SEQUENCE {
|
||
|
cmmBoardType OBJECT IDENTIFIER,
|
||
|
cmmNumModules INTEGER,
|
||
|
cmmModuleNumModems INTEGER,
|
||
|
cmmTFTPServer IpAddress,
|
||
|
cmmUpgradePath DisplayString,
|
||
|
cmmUpgradeFlag INTEGER,
|
||
|
cmmCommitFlag INTEGER,
|
||
|
cmmModemResetLimit INTEGER,
|
||
|
cmmModemResetTime INTEGER,
|
||
|
cmmOutgoingInactivityTimeout INTEGER,
|
||
|
cmmIncomingInactivityTimeout INTEGER,
|
||
|
cmmAsyncBaseOrigATCmdStr DisplayString,
|
||
|
cmmAsyncBaseAnswerATCmdStr DisplayString,
|
||
|
cmmAsyncOrigStrModifier DisplayString,
|
||
|
cmmAsyncAnswerStrModifier DisplayString,
|
||
|
cmmAsyncOperOrigATCmdStr DisplayString,
|
||
|
cmmAsyncOperAnswerATCmdStr DisplayString,
|
||
|
cmmHdlcBaseOrigATCmdStr DisplayString,
|
||
|
cmmHdlcBaseAnswerATCmdStr DisplayString,
|
||
|
cmmHdlcOrigStrModifier DisplayString,
|
||
|
cmmHdlcAnswerStrModifier DisplayString,
|
||
|
cmmHdlcOperOrigATCmdStr DisplayString,
|
||
|
cmmHdlcOperAnswerATCmdStr DisplayString,
|
||
|
cmmBoardAdminStatus INTEGER,
|
||
|
cmmBoardOperStatus INTEGER
|
||
|
}
|
||
|
|
||
|
cmmBoardType OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object uniquely defines the CMM
|
||
|
board type - a vendor's authoritative identification
|
||
|
for a module. By convention, this value is allocated
|
||
|
within the SMI enterprises subtree(1.3.6.1.4.1), and
|
||
|
provides an easy and unambiguous means for determining
|
||
|
the type of board."
|
||
|
::= { cmmBoardEntry 1 }
|
||
|
|
||
|
cmmNumModules OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the number of CMM modules
|
||
|
contained on this physical CMM circuit board."
|
||
|
::= { cmmBoardEntry 2 }
|
||
|
|
||
|
cmmModuleNumModems OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Number of modems per CMM module."
|
||
|
::= { cmmBoardEntry 3 }
|
||
|
|
||
|
cmmTFTPServer OBJECT-TYPE
|
||
|
SYNTAX IpAddress
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the IP address of the TFTP
|
||
|
server where the object code for CMM modules resides.
|
||
|
This object is persistent."
|
||
|
::= { cmmBoardEntry 4 }
|
||
|
|
||
|
cmmUpgradePath OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the path to the object code
|
||
|
for CMM modules on the TFTP server. This object is
|
||
|
persistent."
|
||
|
::= { cmmBoardEntry 5 }
|
||
|
|
||
|
cmmUpgradeFlag OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
true(1),
|
||
|
false(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is a flag that indicates whether
|
||
|
or not to upgrade the software for the CMM modules on the
|
||
|
board. This object is persistent."
|
||
|
::= { cmmBoardEntry 6 }
|
||
|
|
||
|
cmmCommitFlag OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
true(1),
|
||
|
false(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is a flag that indicates whether
|
||
|
or not to commit the software for the CMM modules on the
|
||
|
board. This object is persistent."
|
||
|
::= { cmmBoardEntry 7 }
|
||
|
|
||
|
cmmModemResetLimit OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the number of times that a
|
||
|
modem can be reset within a given time span before it is
|
||
|
declared to be faulty. If the value is 0 then the modem
|
||
|
will never be declared faulty. This object is persistent."
|
||
|
::= { cmmBoardEntry 8 }
|
||
|
|
||
|
cmmModemResetTime OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the time span (in minutes)
|
||
|
during which the given number of resets must occur before
|
||
|
the modem is declared to be faulty. This object is
|
||
|
persistent."
|
||
|
::= { cmmBoardEntry 9 }
|
||
|
|
||
|
cmmOutgoingInactivityTimeout OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the duration (in seconds) of a
|
||
|
period of inactivity before an outgoing call is terminated.
|
||
|
This object is persistent."
|
||
|
::= { cmmBoardEntry 10 }
|
||
|
|
||
|
cmmIncomingInactivityTimeout OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the duration (in seconds) of a
|
||
|
period of inactivity before an incoming call is terminated.
|
||
|
This object is persistent."
|
||
|
::= { cmmBoardEntry 11 }
|
||
|
|
||
|
cmmAsyncBaseOrigATCmdStr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the default or base set of AT
|
||
|
commands to be used when originating an async call."
|
||
|
::= { cmmBoardEntry 12 }
|
||
|
|
||
|
cmmAsyncBaseAnswerATCmdStr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the default or base set of AT
|
||
|
commands to be used when answering an async call."
|
||
|
::= { cmmBoardEntry 13 }
|
||
|
|
||
|
cmmAsyncOrigStrModifier OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is a set of additional AT commands
|
||
|
to be used when originating an async call. This object is
|
||
|
persistent."
|
||
|
::= { cmmBoardEntry 14 }
|
||
|
|
||
|
cmmAsyncAnswerStrModifier OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is a set of additional AT commands
|
||
|
to be used when answering an async call. This object is
|
||
|
persistent."
|
||
|
::= { cmmBoardEntry 15 }
|
||
|
|
||
|
cmmAsyncOperOrigATCmdStr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the operative set of AT commands
|
||
|
to be used when originating an async call. It includes the
|
||
|
base string, the modifier string, and the call timeout value."
|
||
|
::= { cmmBoardEntry 16 }
|
||
|
|
||
|
cmmAsyncOperAnswerATCmdStr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the operative set of AT commands
|
||
|
to be used when answering an async call. It includes the
|
||
|
base string, the modifier string, and the call timeout value."
|
||
|
::= { cmmBoardEntry 17 }
|
||
|
|
||
|
cmmHdlcBaseOrigATCmdStr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the default or base set of AT
|
||
|
commands to be used when originating an HDLC call."
|
||
|
::= { cmmBoardEntry 18 }
|
||
|
|
||
|
cmmHdlcBaseAnswerATCmdStr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the default or base set of AT
|
||
|
commands to be used when answering an HDLC call."
|
||
|
::= { cmmBoardEntry 19 }
|
||
|
|
||
|
cmmHdlcOrigStrModifier OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is a set of additional AT commands
|
||
|
to be used when originating an HDLC call. This object is
|
||
|
persistent."
|
||
|
::= { cmmBoardEntry 20 }
|
||
|
|
||
|
cmmHdlcAnswerStrModifier OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is a set of additional AT commands
|
||
|
to be used when answering an HDLC call. This object is
|
||
|
persistent."
|
||
|
::= { cmmBoardEntry 21 }
|
||
|
|
||
|
cmmHdlcOperOrigATCmdStr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the operative set of AT commands
|
||
|
to be used when originating an HDLC call. It includes the
|
||
|
base string, the modifier string, and the call timeout value."
|
||
|
::= { cmmBoardEntry 22 }
|
||
|
|
||
|
cmmHdlcOperAnswerATCmdStr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the operative set of AT commands
|
||
|
to be used when answering an HDLC call. It includes the
|
||
|
base string, the modifier string, and the call timeout value."
|
||
|
::= { cmmBoardEntry 23 }
|
||
|
|
||
|
cmmBoardAdminStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
down(1),
|
||
|
leave-service(2),
|
||
|
up(3),
|
||
|
upgrade(4)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the administrative status
|
||
|
of the CMM board.
|
||
|
|
||
|
down(1) -- all modems that belong to this board are to be
|
||
|
removed from service immediately
|
||
|
leave-service(2) -- each modem that belongs to this board is
|
||
|
to be removed from service at the completion
|
||
|
of its current call, if any
|
||
|
up(3) -- each modem that belongs to this module is to become
|
||
|
available for accepting calls
|
||
|
upgrade(4) -- all modules that belong to this board are to be
|
||
|
reloaded with new software and restarted"
|
||
|
::= { cmmBoardEntry 24 }
|
||
|
|
||
|
cmmBoardOperStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
initializing(1),
|
||
|
active(2),
|
||
|
leaving-service(3),
|
||
|
out-of-service(4),
|
||
|
faulty(5),
|
||
|
impaired(6)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the operational status of
|
||
|
the CMM board.
|
||
|
|
||
|
initializing(1) -- all modules that belong to this board are booting
|
||
|
up or in the process of a software upgrade
|
||
|
active(2) -- all modules that belong to this board are available
|
||
|
for accepting calls
|
||
|
leaving-service(3) -- all modules that belong to this board are
|
||
|
functional but are no longer available for
|
||
|
accepting calls (Existing calls are allowed
|
||
|
to terminate normally.)
|
||
|
out-of-service(4) -- none of the modules that belong to this board
|
||
|
are available for accepting calls nor do they
|
||
|
have any existing calls
|
||
|
faulty(5) -- all modules that belong to this board are unusable
|
||
|
impaired(6) -- the board is otherwise active but one or more
|
||
|
modules are in the out-of-service, initializing,
|
||
|
testing, faulty, or impaired states"
|
||
|
::= { cmmBoardEntry 25 }
|
||
|
|
||
|
--================= CMM Module-Level Info ===================
|
||
|
cmmModuleTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CmmModuleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of CMM modules present on each CMM board in this unit"
|
||
|
::= { cmmModemInfo 2 }
|
||
|
|
||
|
cmmModuleEntry OBJECT-TYPE
|
||
|
SYNTAX CmmModuleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is a CMM module that is
|
||
|
present in this unit"
|
||
|
INDEX { mBusBoardID, cmmModuleID }
|
||
|
::= { cmmModuleTable 1 }
|
||
|
|
||
|
CmmModuleEntry ::=
|
||
|
SEQUENCE {
|
||
|
cmmModuleID INTEGER,
|
||
|
cmmDpramSize INTEGER,
|
||
|
cmmSdramSize INTEGER,
|
||
|
cmmCpuType INTEGER,
|
||
|
cmmCpuSpeed INTEGER,
|
||
|
cmmCpuFwRev DisplayString,
|
||
|
cmmEpldId DisplayString,
|
||
|
cmmEpldRev DisplayString,
|
||
|
cmmNumBadModems INTEGER,
|
||
|
cmmModuleOperStatus INTEGER,
|
||
|
cmmModuleAdminStatus INTEGER
|
||
|
}
|
||
|
|
||
|
cmmModuleID OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is an index that uniquely identifies
|
||
|
the CMM module within the physical CMM board."
|
||
|
::= { cmmModuleEntry 1 }
|
||
|
|
||
|
cmmDpramSize OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Size of the DPRAM (in bytes) on the CMM module."
|
||
|
::= { cmmModuleEntry 2 }
|
||
|
|
||
|
cmmSdramSize OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Size of the SDRAM (in bytes) on the CMM module."
|
||
|
::= { cmmModuleEntry 3 }
|
||
|
|
||
|
cmmCpuType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown(1),
|
||
|
hitachish3(2),
|
||
|
hitachish4(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"CPU type on the CMM module."
|
||
|
::= { cmmModuleEntry 4 }
|
||
|
|
||
|
cmmCpuSpeed OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The speed of the CPU (in Megahertz) on the CMM module."
|
||
|
::= { cmmModuleEntry 5 }
|
||
|
|
||
|
cmmCpuFwRev OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Revision of the CPU firmware on the CMM module. This code
|
||
|
is a product of RSA."
|
||
|
::= { cmmModuleEntry 6 }
|
||
|
|
||
|
cmmEpldId OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"EPLD ID on the CMM module. (Read from the Altera chip.)"
|
||
|
::= { cmmModuleEntry 7 }
|
||
|
|
||
|
cmmEpldRev OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Revision of the EPLD firmware on the CMM module. This
|
||
|
code is produced by Cabletron."
|
||
|
::= { cmmModuleEntry 8 }
|
||
|
|
||
|
cmmNumBadModems OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the number of bad modems
|
||
|
on the CMM module."
|
||
|
::= { cmmModuleEntry 9 }
|
||
|
|
||
|
cmmModuleAdminStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
down(1),
|
||
|
leave-service(2),
|
||
|
up(3),
|
||
|
run-diagnostics(4),
|
||
|
reset(5),
|
||
|
faulty(6)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the administrative status
|
||
|
of the CMM module.
|
||
|
|
||
|
down(1) -- all modems that belong to this module are to be
|
||
|
removed from service immediately
|
||
|
leave-service(2) -- each modem that belongs to this module is
|
||
|
to be removed from service at the completion
|
||
|
of its current call, if any
|
||
|
up(3) -- each modem that belongs to this module is to become
|
||
|
available for accepting calls
|
||
|
run-diagnostics(4) -- all modems that belong to this module are
|
||
|
to run a series of comprehensive on-line
|
||
|
diagnostic tests
|
||
|
reset(5) -- the entire module is to be physically reset
|
||
|
faulty(6) -- the entire module is to be immediately removed from
|
||
|
service and considered unusable"
|
||
|
::= { cmmModuleEntry 10 }
|
||
|
|
||
|
cmmModuleOperStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
initializing(1),
|
||
|
active(2),
|
||
|
leaving-service(3),
|
||
|
out-of-service(4),
|
||
|
faulty(5),
|
||
|
impaired(6)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of this object is the operational status of
|
||
|
the CMM module.
|
||
|
|
||
|
initializing(1) -- the module is booting up or in the process of
|
||
|
a software upgrade
|
||
|
active(2) -- all modems that belong to this module are available
|
||
|
for accepting calls
|
||
|
leaving-service(3) -- all modems that belong to this module are
|
||
|
functional but are no longer available for
|
||
|
accepting calls (Existing calls are allowed
|
||
|
to terminate normally.)
|
||
|
out-of-service(4) -- none of the modems that belong to this module
|
||
|
are available for accepting calls nor do they
|
||
|
have any existing calls
|
||
|
faulty(5) -- the module has been removed from service by an NMS and
|
||
|
is considered to be unusable
|
||
|
impaired(6) -- the module is otherwise active but one or more
|
||
|
modems are in the out-of-service, initializing,
|
||
|
testing, or faulty states"
|
||
|
::= { cmmModuleEntry 11 }
|
||
|
|
||
|
|
||
|
--================= CMM Modem-Level Info ===================
|
||
|
cmmModemTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CmmModemEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of modems present on each CMM module on each CMM board
|
||
|
in this unit"
|
||
|
::= { cmmModemInfo 3 }
|
||
|
|
||
|
cmmModemEntry OBJECT-TYPE
|
||
|
SYNTAX CmmModemEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains data for a single CMM modem."
|
||
|
INDEX { ifIndex }
|
||
|
::= { cmmModemTable 1 }
|
||
|
|
||
|
CmmModemEntry ::=
|
||
|
SEQUENCE {
|
||
|
cmmBoardID INTEGER,
|
||
|
cmmModemID INTEGER,
|
||
|
cmmIFNum INTEGER,
|
||
|
cmmSessionNum INTEGER,
|
||
|
cmmDdpPartNum DisplayString,
|
||
|
cmmDdpRevLevel DisplayString,
|
||
|
cmmDdpFwRev DisplayString,
|
||
|
cmmDDPInterrupts Counter,
|
||
|
cmmRxFlowCtlEvts Counter,
|
||
|
cmmTxFlowCtlEvts Counter,
|
||
|
cmmCallStatus INTEGER,
|
||
|
cmmCallOrigin INTEGER,
|
||
|
cmmRobbedBitDetected DisplayString,
|
||
|
cmmCorrectionType INTEGER,
|
||
|
cmmCompressionType INTEGER,
|
||
|
cmmRxRate INTEGER,
|
||
|
cmmTxRate INTEGER,
|
||
|
cmmEncoding INTEGER,
|
||
|
cmmFraming INTEGER,
|
||
|
cmmInitialConnectRate INTEGER,
|
||
|
cmmMaxHostWindows INTEGER,
|
||
|
cmmMaxCmmWindows INTEGER,
|
||
|
cmmNumOutHostAcks Gauge,
|
||
|
cmmNumOutCmmAcks Gauge,
|
||
|
cmmToNetworkOctets Counter,
|
||
|
cmmFromNetworkOctets Counter,
|
||
|
cmmToHostOctets Counter,
|
||
|
cmmFromHostOctets Counter,
|
||
|
cmmToNetworkFrames Counter,
|
||
|
cmmFromNetworkFrames Counter,
|
||
|
cmmOversizeFrames Counter,
|
||
|
cmmOverrunErrors Counter,
|
||
|
cmmCRCErrors Counter,
|
||
|
cmmAbortedFrames Counter,
|
||
|
cmmRetrainEvents Counter,
|
||
|
cmmARAEvents Counter,
|
||
|
cmmARAFlag INTEGER,
|
||
|
cmmCarrierLossEvents Counter,
|
||
|
cmmCarrierLossFlag INTEGER,
|
||
|
cmmRcvSignalLevel INTEGER,
|
||
|
cmmRcvSignalEQM INTEGER,
|
||
|
cmmTDMSlot INTEGER,
|
||
|
cmmResetModemStats INTEGER,
|
||
|
cmmModemAdminStatus INTEGER,
|
||
|
cmmModemOperStatus INTEGER
|
||
|
}
|
||
|
|
||
|
cmmBoardID OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the logical number of the CMM board to which
|
||
|
the modem belongs."
|
||
|
::= { cmmModemEntry 1 }
|
||
|
|
||
|
cmmModemID OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the logical number of the modem on the CMM
|
||
|
module to which the modem belongs."
|
||
|
::= { cmmModemEntry 2 }
|
||
|
|
||
|
cmmIFNum OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of the instance of the Interface
|
||
|
MIB that is associated with this modem."
|
||
|
::= { cmmModemEntry 3 }
|
||
|
|
||
|
cmmSessionNum OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the session number that is associated with
|
||
|
this modem. Session numbers are assigned, starting with 1, from
|
||
|
the first modem on the first module of the first CMM board and
|
||
|
continuing through the last modem of the last module of the last
|
||
|
CMM board."
|
||
|
::= { cmmModemEntry 4 }
|
||
|
|
||
|
cmmDdpPartNum OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Part number of the DDP controller on the CMM module.
|
||
|
(Read from the DDP chip.)"
|
||
|
::= { cmmModemEntry 5 }
|
||
|
|
||
|
cmmDdpRevLevel OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Revision level of the DDP controller on the CMM module.
|
||
|
(Read from the DDP chip.)"
|
||
|
::= { cmmModemEntry 6 }
|
||
|
|
||
|
cmmDdpFwRev OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Revison of the DDP controller firmware on the CMM module.
|
||
|
This code is produced by Rockwell."
|
||
|
::= { cmmModemEntry 7 }
|
||
|
|
||
|
cmmDDPInterrupts OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of interrupts received by the CMM
|
||
|
transfer manager since initialization."
|
||
|
::= { cmmModemEntry 8 }
|
||
|
|
||
|
cmmRxFlowCtlEvts OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of received flow control events."
|
||
|
::= { cmmModemEntry 9 }
|
||
|
|
||
|
cmmTxFlowCtlEvts OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of transmitted flow control events."
|
||
|
::= { cmmModemEntry 10 }
|
||
|
|
||
|
cmmCallStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
idle(1),
|
||
|
connected(2),
|
||
|
retraining(3),
|
||
|
dropping(4),
|
||
|
local-test(5),
|
||
|
remote-test(6)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the current call status."
|
||
|
::= { cmmModemEntry 11 }
|
||
|
|
||
|
cmmCallOrigin OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
answer(1),
|
||
|
originate(2)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains an enumerated value that indicates whether
|
||
|
the call originated locally or remotely."
|
||
|
::= { cmmModemEntry 12 }
|
||
|
|
||
|
cmmRobbedBitDetected OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the robbed bit signalling pattern that was
|
||
|
detected by the modem or 0 if none."
|
||
|
::= { cmmModemEntry 13 }
|
||
|
|
||
|
cmmCorrectionType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
no-ec(1),
|
||
|
detection(2),
|
||
|
mnp(3),
|
||
|
hanging-up(4),
|
||
|
speed-matching(5),
|
||
|
lapm(6),
|
||
|
mnp10(7)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains an enumerated value that indicates the type
|
||
|
of error correction that was negotiated."
|
||
|
::= { cmmModemEntry 14 }
|
||
|
|
||
|
cmmCompressionType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
none(1),
|
||
|
mnp-class-5(2),
|
||
|
v42bis-tx-only(3),
|
||
|
v42bis-rx-only(4),
|
||
|
v42bis(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains an enumerated value that indicates the type
|
||
|
of data compression that was negotiated."
|
||
|
::= { cmmModemEntry 15 }
|
||
|
|
||
|
cmmRxRate OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the current receive rate."
|
||
|
::= { cmmModemEntry 16 }
|
||
|
|
||
|
cmmTxRate OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the current transmit rate."
|
||
|
::= { cmmModemEntry 17 }
|
||
|
|
||
|
cmmEncoding OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
u-law(1),
|
||
|
a-law(2)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the current PCM encoding type."
|
||
|
::= { cmmModemEntry 18 }
|
||
|
|
||
|
cmmFraming OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
pseudo-framing(1),
|
||
|
hdlc-framing(2),
|
||
|
ppp-async(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the current framing type."
|
||
|
::= { cmmModemEntry 19 }
|
||
|
|
||
|
cmmInitialConnectRate OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the initial connect rate (in BPS) or the session."
|
||
|
::= { cmmModemEntry 20 }
|
||
|
|
||
|
cmmMaxHostWindows OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the maximum number of host windows."
|
||
|
::= { cmmModemEntry 21 }
|
||
|
|
||
|
cmmMaxCmmWindows OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the maximum number of CMM windows."
|
||
|
::= { cmmModemEntry 22 }
|
||
|
|
||
|
cmmNumOutHostAcks OBJECT-TYPE
|
||
|
SYNTAX Gauge
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of host window acks that
|
||
|
have not been processed by the CMM side."
|
||
|
::= { cmmModemEntry 23 }
|
||
|
|
||
|
cmmNumOutCmmAcks OBJECT-TYPE
|
||
|
SYNTAX Gauge
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of CMM window acks that
|
||
|
have not been processed by the host side."
|
||
|
::= { cmmModemEntry 24 }
|
||
|
|
||
|
cmmToNetworkOctets OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of data bytes transmitted
|
||
|
(modem -> central office switch)."
|
||
|
::= { cmmModemEntry 25 }
|
||
|
|
||
|
cmmFromNetworkOctets OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of data bytes received
|
||
|
(central office switch -> modem)."
|
||
|
::= { cmmModemEntry 26 }
|
||
|
|
||
|
cmmToHostOctets OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of data bytes transmitted
|
||
|
(modem -> m-bus host)."
|
||
|
::= { cmmModemEntry 27 }
|
||
|
|
||
|
cmmFromHostOctets OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of data bytes received
|
||
|
(m-bus host -> modem)."
|
||
|
::= { cmmModemEntry 28 }
|
||
|
|
||
|
cmmToNetworkFrames OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of frames transmitted
|
||
|
(modem -> central office switch)."
|
||
|
::= { cmmModemEntry 29 }
|
||
|
|
||
|
cmmFromNetworkFrames OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of frames received
|
||
|
(central office switch -> modem)."
|
||
|
::= { cmmModemEntry 30 }
|
||
|
|
||
|
cmmOversizeFrames OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of HDLC frames received that were
|
||
|
greater than the maximum permissible size."
|
||
|
::= { cmmModemEntry 31 }
|
||
|
|
||
|
cmmOverrunErrors OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of HDLC overrun errors."
|
||
|
::= { cmmModemEntry 32 }
|
||
|
|
||
|
cmmCRCErrors OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of HDLC CRC errors."
|
||
|
::= { cmmModemEntry 33 }
|
||
|
|
||
|
cmmAbortedFrames OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of HDLC frames that were aborted
|
||
|
while they were being received."
|
||
|
::= { cmmModemEntry 34 }
|
||
|
|
||
|
cmmRetrainEvents OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of times that retrain and
|
||
|
renegotiation events have occurred since initialization."
|
||
|
::= { cmmModemEntry 35 }
|
||
|
|
||
|
cmmARAEvents OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of times that automatic
|
||
|
rate adaption events have occurred."
|
||
|
::= { cmmModemEntry 36 }
|
||
|
|
||
|
cmmARAFlag OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
true(1),
|
||
|
false(2)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains a flag that indicates whether or not
|
||
|
an ARA event has occurred during the current session."
|
||
|
::= { cmmModemEntry 37 }
|
||
|
|
||
|
cmmCarrierLossEvents OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of times that carrier loss
|
||
|
events have occurred."
|
||
|
::= { cmmModemEntry 38 }
|
||
|
|
||
|
cmmCarrierLossFlag OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
true(1),
|
||
|
false(2)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains a flag that indicates whether or not a
|
||
|
carrier loss event has occurred during the current session."
|
||
|
::= { cmmModemEntry 39 }
|
||
|
|
||
|
cmmRcvSignalLevel OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the receive signal level."
|
||
|
::= { cmmModemEntry 40 }
|
||
|
|
||
|
cmmRcvSignalEQM OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the receive signal EQM."
|
||
|
::= { cmmModemEntry 41 }
|
||
|
|
||
|
cmmTDMSlot OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the number of the TDM slot used by this
|
||
|
session."
|
||
|
::= { cmmModemEntry 42 }
|
||
|
|
||
|
cmmResetModemStats OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
true(1),
|
||
|
false(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object is used to reset the statistics pertaining to
|
||
|
the selected modem. If written with the value 'true', the
|
||
|
statistics will be reset. If written with the value 'false',
|
||
|
no action will be taken. Its value will always be read as
|
||
|
'false'."
|
||
|
::= { cmmModemEntry 43 }
|
||
|
|
||
|
cmmModemAdminStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
down(1),
|
||
|
leave-service(2),
|
||
|
up(3),
|
||
|
run-diagnostics(4),
|
||
|
reset(5),
|
||
|
faulty(6)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the administrative status of a modem.
|
||
|
|
||
|
down(1) -- the modem is to be removed from service immediately
|
||
|
leave-service(2) -- the modem is to be removed from service at
|
||
|
the completion of its current call, if any
|
||
|
up(3) -- the modem is to become available for accepting calls
|
||
|
run-diagnostics(4) -- the modem is to run a series of
|
||
|
comprehensive on-line diagnostic tests
|
||
|
reset(5) -- the modem is to be physically reset
|
||
|
faulty(6) -- the modem is to be immediately removed from
|
||
|
service and considered unusable"
|
||
|
::= { cmmModemEntry 44 }
|
||
|
|
||
|
cmmModemOperStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
initializing(1),
|
||
|
idle(2),
|
||
|
active(3),
|
||
|
leaving-service(4),
|
||
|
out-of-service(5),
|
||
|
testing(6),
|
||
|
faulty(7),
|
||
|
resetting(8)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the operational status of a modem.
|
||
|
|
||
|
initializing(1) -- the module to which the modem belongs is booting
|
||
|
up or in the process of a software upgrade
|
||
|
idle(2) -- the modem is available for accepting calls but has no
|
||
|
call in place
|
||
|
active(3) -- the modem is not available for accepting calls because
|
||
|
it already has one in place
|
||
|
leaving-service(4) -- the modem is functional but is no longer
|
||
|
available for accepting calls (Existing calls
|
||
|
are allowed to terminate normally.)
|
||
|
out-of-service(5) -- the modem is neither available for accepting
|
||
|
calls nor does it have a call in place
|
||
|
testing(6) -- the modem is running a series of comprehensive on-line
|
||
|
diagnostic tests
|
||
|
faulty(7) -- the modem has been removed from service by an NMS or
|
||
|
due to a hardware or software failure and is considered
|
||
|
to be unusable
|
||
|
resetting(8) -- the modem is executing a reset sequence"
|
||
|
::= { cmmModemEntry 45 }
|
||
|
|
||
|
--================= Free-Form AT Command Group ===================
|
||
|
|
||
|
cmmFreeFormAtCmdGroup OBJECT IDENTIFIER ::= { cmmModemInfo 5 }
|
||
|
|
||
|
cmmATCommand OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the user-defined AT command string. It
|
||
|
can contain up to 256 characters, including a carriage return
|
||
|
that will automatically be inserted and a NULL terminator."
|
||
|
::= { cmmFreeFormAtCmdGroup 1 }
|
||
|
|
||
|
cmmSelectedModem OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the ID of the modem to which the free-form
|
||
|
AT command string should be sent."
|
||
|
::= { cmmFreeFormAtCmdGroup 2 }
|
||
|
|
||
|
cmmATCmdStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
sending(1),
|
||
|
not-sending(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object allows the free-form AT command string to be sent
|
||
|
and allows the status of the command string to be examined."
|
||
|
::= { cmmFreeFormAtCmdGroup 3 }
|
||
|
|
||
|
cmmATCmdResult OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object contains the result string from issuing the
|
||
|
free-form AT command ."
|
||
|
::= { cmmFreeFormAtCmdGroup 4 }
|
||
|
|
||
|
END
|