mibs/MIBS/enterasys/CTINB-MIB

493 lines
17 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
CTINB-MIB DEFINITIONS ::= BEGIN
-- ctinb-info-mib
-- Revision: 01.00.00
-- Date: October 14, 1996
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- support@ctron.com
--
-- This module will be extended, as needed.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright August 96 Cabletron Systems
IMPORTS
Counter, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
ctINBinfo
FROM CTRON-MIB-NAMES ;
--
-- The inbMonarchsystem table represents the Monarch(INB mgr) information
-- on a per INB basis
--
--
inbMonarchSystem OBJECT IDENTIFIER ::= { ctINBinfo 1 }
inbMonarchSystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF InbMonarchSystemEntry
ACCESS not-accessible
STATUS mandatory
::= { inbMonarchSystem 1 }
inbMonarchSystemEntry OBJECT-TYPE
SYNTAX InbMonarchSystemEntry
ACCESS not-accessible
STATUS mandatory
INDEX { inbMonarchINB }
::= { inbMonarchSystemTable 1 }
InbMonarchSystemEntry ::=
SEQUENCE {
inbMonarchSystemINB
INTEGER,
inbMonarchStatusTimeStamp
TimeTicks,
inbMonarchBandwidth
INTEGER,
inbMonarchTDMSlotMode
INTEGER,
inbMonarchTDMSlotTotal
INTEGER,
inbMonarchSystemTDMSlotActual
INTEGER,
inbMonarchTDMSlotbandwidth
INTEGER
}
inbMonarchSystemINB OBJECT-TYPE
SYNTAX INTEGER{
inbA(1),
inbB(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Two physical INB's may exist on a module. This
object distinquishes which INB, INB-A or INB-B."
::= { inbMonarchSystemEntry 1 }
inbMonarchStatusTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object represents the value of sysUptime when
the Monarch last changed."
::= { inbMonarchSystemEntry 2 }
inbMonarchBandwidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bandwidth of this INB in Megabits."
::= { inbMonarchSystemEntry 3 }
inbMonarchTDMSlotMode OBJECT-TYPE
SYNTAX INTEGER {
automatic(1),
userPolicy(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The automatic TDM mode overides any preset TDM
allocation. All boards get an equal number of
pre-allocated TDM slots, adding up to 100% of total
INB bandwidth, and have Round Robin enabled. The
automatic mode will, in effect, provide each board
with a 1/(number of boards) minimum guarantee
INB bandwidth.
The userPolicy mode will have the per board policy
enforced. Each board will have a level of service
(TDM slots, Round Robin arbitration from the
inbMonarchTable) associated with it to take effect
when this object is set to user_policy. Newly
inserted boards will default to Round Robin and
share the remaining fixed INB bandwidth
(inbMonarchTDMSlotTotal - inbMonarchTDMSlotActual)."
::= { inbMonarchSystemEntry 4 }
inbMonarchTDMSlotTotal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object represents the total possible number of INB
backplane TDM slots."
::= { inbMonarchSystemEntry 5 }
inbMonarchSystemTDMSlotActual OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object represents the total number of allocated INB
backplane TDM slots. This is the sum of all instances of
inbMonarchTDMSlotRequest in userPolicy mode. In automatic
mode this number would represent the number of inserted
boards."
::= { inbMonarchSystemEntry 6 }
inbMonarchTDMSlotbandwidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object represents the bandwidth in bits that
each slot represents on the backplane."
::= { inbMonarchSystemEntry 7 }
--
-- The inbMonarchTable table represents the Monarch(INB mgr) configuration information
-- on a per board/slot basis
--
--
inbMonarch OBJECT IDENTIFIER ::= { ctINBinfo 2 }
inbMonarchTable OBJECT-TYPE
SYNTAX SEQUENCE OF InbMonarchEntry
ACCESS not-accessible
STATUS mandatory
::= { inbMonarch 1 }
inbMonarchEntry OBJECT-TYPE
SYNTAX InbMonarchEntry
ACCESS not-accessible
STATUS mandatory
INDEX { inbMonarchSlot,
inbMonarchINB }
::= { inbMonarchTable 1 }
InbMonarchEntry ::=
SEQUENCE {
inbMonarchSlot
INTEGER,
inbMonarchINB
INTEGER,
inbMonarchStatus
INTEGER,
inbMonarchLinkStatus
INTEGER,
inbMonarchLinkCapacity
INTEGER,
inbMonarchTDMSlotRequest
INTEGER,
inbMonarchTDMSlotActual
INTEGER,
inbMonarchRoundRobinControl
INTEGER
}
inbMonarchSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number containing this module."
::= { inbMonarchEntry 1 }
inbMonarchINB OBJECT-TYPE
SYNTAX INTEGER{
inbA(1),
inbB(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Two physical INB interfaces may exist on a module. This
object distinquishes which INB, INB-A or INB-B."
::= { inbMonarchEntry 2 }
inbMonarchStatus OBJECT-TYPE
SYNTAX INTEGER {
standBy(1),
sysUndefined(2),
operational(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Application state of the monarch application on this
module. Standby - indicates this module is not the
monarch but can be. SysUndefined - indicates this
module can not be monarch. Operational - says this
module is the monarch. "
::= { inbMonarchEntry 3 }
inbMonarchLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
linkUp(1),
linkDown(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object describes the state of the backplane. LinkUp
is when this INB detects the clock on the backplane.
LinkDown is when no backplane clock has been detected."
::= { inbMonarchEntry 4 }
inbMonarchLinkCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bandwidth capacity of this board in Megabytes."
::= { inbMonarchEntry 5 }
inbMonarchTDMSlotRequest OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is the number of fixed TDM slots requested
for this board . NOTE: new request will take effect the
next time the inbMonarchTDMSlotMode object is set to
userPolicy. NOTE: this value has no meaning when the
inbMonarchTDMSlotMode is automatic."
::= { inbMonarchEntry 6 }
inbMonarchTDMSlotActual OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is the actual number of fixed TDM slots
given to this board. In automatic mode, this value is the
total number of slots divided by the number of inserted
boards, in userPolicy mode, this reflects the
inbMonarchTDMSlotRequest value at the last time the
chassis entered userPolicy mode."
::= { inbMonarchEntry 7 }
inbMonarchRoundRobinControl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object enables or disable this INB the ability to
participate in the Round Robin arbitration phase."
::= { inbMonarchEntry 8 }
--
--
-- inbstats are the basic per board INB statistics
--
--
--
--
--
inbStats OBJECT IDENTIFIER ::= { ctINBinfo 3 }
inbStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF InbStatsEntry
ACCESS not-accessible
STATUS mandatory
::= { inbStats 1 }
inbStatsEntry OBJECT-TYPE
SYNTAX InbStatsEntry
ACCESS not-accessible
STATUS mandatory
INDEX { inbStatsSlot,
inbStatsINB }
::= { inbStatsTable 1 }
InbStatsEntry ::=
SEQUENCE {
inbStatsSlot
INTEGER,
inbStatsINB
INTEGER,
inbStatsIfindex
INTEGER,
inbStatsUniCastCells
Counter,
inbStatsMultiCastCells
Counter,
inbStatsBroadCastCells
Counter,
inbStatsXmitCells
Counter,
inbStatsRecvSeqErrs
Counter,
inbStatsRecvChksumErrs
Counter,
inbStatsxmitToFps
Counter,
inbStatsToFpsDrops
Counter,
inbStatsFromInbErrs
Counter,
inbStatsToINBDrops
Counter,
inbStatsToInbErrs
Counter
}
inbStatsSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number containing this module."
::= { inbStatsEntry 1 }
inbStatsINB OBJECT-TYPE
SYNTAX INTEGER {
inbA(1),
inbB(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Two physical INB interfaces may exist on a module. This
object distinquishes which INB, INB-A or INB-B."
::= { inbStatsEntry 2 }
inbStatsIfindex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interface number of the INB. The interface
identified by a particular value of this
object is the same interface as identified by the
same value of the ifIndex object defined in RFC 1213."
::= { inbStatsEntry 3 }
inbStatsUniCastCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of UniCast INB cells received from the backplane."
::= { inbStatsEntry 4 }
inbStatsMultiCastCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of multi-cast INB cells received from the backplane."
::= { inbStatsEntry 5 }
inbStatsBroadCastCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of broadcast INB cells received from the backplane."
::= { inbStatsEntry 6 }
inbStatsXmitCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of INB cells transmitted to the backplane."
::= { inbStatsEntry 7 }
inbStatsRecvSeqErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of pkts with sequence errors received from
the backplane."
::= { inbStatsEntry 8 }
inbStatsRecvChksumErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of pkts with checksum errors received from
the backplane."
::= { inbStatsEntry 9 }
inbStatsxmitToFps OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of transmit errors to FPS."
::= { inbStatsEntry 10 }
inbStatsToFpsDrops OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"INBC receive fifo full count. This represents the
number of cells that were not forwarded to the FPS."
::= { inbStatsEntry 11 }
inbStatsFromInbErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of INB receive errors from the backplane. This
includes FPSC xmit errors(inbStatsxmitToFps), INBC
receive sequence errors (inbStatsRecvSeqErrs)
and INBC checksum errors(inbStatsRecvChksumErrs)."
::= { inbStatsEntry 12 }
inbStatsToINBDrops OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of FPSC recv frame drop count. This represents
the number of frames that were not sent out on the INB
backplane."
::= { inbStatsEntry 13 }
inbStatsToInbErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of INB backplane transmit errors. This includes
FPSC receive timeout errors"
::= { inbStatsEntry 14 }
END