CTRON-POWER-SUPPLY-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
-- ctron-power-supply-mib.txt The power supply MIB
|
||
|
-- Revision: 1.01.02
|
||
|
-- Part Number:
|
||
|
-- Date: March 26, 1997
|
||
|
|
||
|
-- Cabletron Systems, Inc.
|
||
|
-- 35 Industrial Way, P.O. Box 5005
|
||
|
-- Rochester, NH 03867-0505
|
||
|
-- (603) 332-9400
|
||
|
-- support@ctron.com
|
||
|
|
||
|
-- This module provides authoritative definitions for Cabletron's
|
||
|
-- enterprise-specific chassis MIB.
|
||
|
--
|
||
|
-- This module will be extended, as needed.
|
||
|
--
|
||
|
|
||
|
-- Cabletron Systems reserves the right to make changes in
|
||
|
-- specification and other information contained in this document
|
||
|
-- without prior notice. The reader should consult Cabletron Systems
|
||
|
-- to determine whether any such changes have been made.
|
||
|
--
|
||
|
-- In no event shall Cabletron Systems be liable for any incidental,
|
||
|
-- indirect, special, or consequential damages whatsoever (including
|
||
|
-- but not limited to lost profits) arising out of or related to this
|
||
|
-- document or the information contained in it, even if Cabletron
|
||
|
-- Systems has been advised of, known, or should have known, the
|
||
|
-- possibility of such damages.
|
||
|
--
|
||
|
-- Cabletron grants vendors, end-users, and other interested parties
|
||
|
-- a non-exclusive license to use this Specification in connection
|
||
|
-- with the management of Cabletron products.
|
||
|
|
||
|
-- Copyright August 95 Cabletron Systems
|
||
|
|
||
|
|
||
|
-- This MIB describes objects for MMAC+ style power supplies.
|
||
|
|
||
|
IMPORTS
|
||
|
ctps
|
||
|
FROM CTRON-MIB-NAMES
|
||
|
OBJECT-TYPE
|
||
|
FROM RFC-1212;
|
||
|
|
||
|
|
||
|
|
||
|
--=============== group definitions ===================
|
||
|
|
||
|
chPower OBJECT IDENTIFIER ::= { ctps 1 }
|
||
|
boardPower OBJECT IDENTIFIER ::= { ctps 2 }
|
||
|
psPower OBJECT IDENTIFIER ::= { ctps 3 }
|
||
|
bbuPower OBJECT IDENTIFIER ::= { ctps 4 }
|
||
|
termPower OBJECT IDENTIFIER ::= { ctps 5 }
|
||
|
|
||
|
--=============== chPower group ====================
|
||
|
|
||
|
-- Chassis Power Group
|
||
|
-- Implementation of the Chassis Power group is optional.
|
||
|
-- It needs to be supported when an EM is present and operational
|
||
|
-- in the chassis.
|
||
|
-- This group covers information on the chassis power available.
|
||
|
|
||
|
chPowerOperationalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
powerAC(1),
|
||
|
powerACRedundant(2),
|
||
|
powerDC(3),
|
||
|
powerDCRedundant(4),
|
||
|
battery(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object reflects the overall status of the chassis's
|
||
|
power supply in terms of how the power is being delivered
|
||
|
to the chassis."
|
||
|
::= { chPower 1 }
|
||
|
|
||
|
chPowerMainVoltageStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
powerOK(1),
|
||
|
overCurrent(2),
|
||
|
overVoltage(3),
|
||
|
underVoltage(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object reflects the state of the main voltage
|
||
|
rail within the chassis. The power on this rail may
|
||
|
be delivered by AC supplies, DC supplies or battery
|
||
|
supplies."
|
||
|
::= { chPower 2 }
|
||
|
|
||
|
chPowerMainVoltage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The voltage of the chassis's main voltage rail. This rail
|
||
|
carries power to all the modules in the chassis. It has
|
||
|
an allowable range of 40 volts to 60 volts DC. The value
|
||
|
of this object is the actual voltage * 10."
|
||
|
::= { chPower 3 }
|
||
|
|
||
|
chPowerTotalSupply OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The total power being supplied by the chassis's power
|
||
|
supplies to the chassis. The value of this object is the
|
||
|
actual watts."
|
||
|
::= { chPower 4 }
|
||
|
|
||
|
chPowerTotalLoad OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The total load being presented by the chassis to the
|
||
|
chassis's power supplies. The value of
|
||
|
this object is the actual watts."
|
||
|
::= { chPower 5 }
|
||
|
|
||
|
chPowerMaxSupply OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum power that could de supplied by the chassis's power
|
||
|
supplies to the chassis. The value of this object is the
|
||
|
actual watts."
|
||
|
::= { chPower 6 }
|
||
|
|
||
|
chPowerMaxLoad OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum load that could be presented by the chassis to the
|
||
|
chassis's power supplies. The value of
|
||
|
this object is the actual watts."
|
||
|
::= { chPower 7 }
|
||
|
|
||
|
chPowerTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF ChPowerEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of power lines or busses on the chassis's backplane."
|
||
|
::= { chPower 8 }
|
||
|
|
||
|
chPowerEntry OBJECT-TYPE
|
||
|
SYNTAX ChPowerEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A slot entry containing objects for a particular
|
||
|
module and associated power line."
|
||
|
INDEX { chPowerLineID }
|
||
|
::= { chPowerTable 1 }
|
||
|
|
||
|
ChPowerEntry ::=
|
||
|
SEQUENCE {
|
||
|
chPowerLineID
|
||
|
INTEGER,
|
||
|
chPowerLineType
|
||
|
OBJECT IDENTIFIER,
|
||
|
chPowerLineTotalSupply
|
||
|
INTEGER,
|
||
|
chPowerLineTotalLoad
|
||
|
INTEGER,
|
||
|
chPowerLineMaxSupply
|
||
|
INTEGER,
|
||
|
chPowerLineMaxLoad
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
chPowerLineID OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A unique value used to identify a particular power line on
|
||
|
the chassis's backplane."
|
||
|
::= { chPowerEntry 1 }
|
||
|
|
||
|
chPowerLineType OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The type of power. For example, a power line that supplies
|
||
|
DC current at a nominal voltage of 40 to 57 volts or a
|
||
|
power line that supplies AC current at a nominal volatge of
|
||
|
110v."
|
||
|
::= { chPowerEntry 2 }
|
||
|
|
||
|
chPowerLineTotalSupply OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The total power being supplied by the chassis's power
|
||
|
supplies to the chassis on this power line. The value
|
||
|
of this object is the actual watts."
|
||
|
::= { chPowerEntry 3 }
|
||
|
|
||
|
chPowerLineTotalLoad OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The total load being presented by the chassis to the
|
||
|
chassis's power supplies on this power line. This value
|
||
|
will be zero if unknown The value of this object is the
|
||
|
actual watts."
|
||
|
::= { chPowerEntry 4 }
|
||
|
|
||
|
chPowerLineMaxSupply OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum power that could de supplied by the chassis's power
|
||
|
supplies to the chassison this power line. The value of
|
||
|
this object is the actual watts."
|
||
|
::= { chPowerEntry 5 }
|
||
|
|
||
|
chPowerLineMaxLoad OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum load that could be presented by the chassis to the
|
||
|
chassis's power supplies on this power line. The value of
|
||
|
this object is the actual watts."
|
||
|
::= { chPowerEntry 6 }
|
||
|
|
||
|
chPowerDiagVoltageStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
powerOK(1),
|
||
|
overCurrent(2),
|
||
|
overVoltage(3),
|
||
|
underVoltage(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object reflects the state of the diag voltage
|
||
|
rail within the chassis."
|
||
|
::= { chPower 9 }
|
||
|
|
||
|
chPowerDiagVoltage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The voltage of the chassis's diag voltage rail. This rail
|
||
|
carries power to all the modules in the chassis. It has
|
||
|
an allowable range of 4.75 volts to 5.25 volts DC. The value
|
||
|
of this object is the actual voltage * 10."
|
||
|
::= { chPower 10 }
|
||
|
|
||
|
--=============== boardPower group ====================
|
||
|
|
||
|
-- Board Power Group
|
||
|
-- This group covers information on the use of power within the
|
||
|
-- chassis by the networking boards.
|
||
|
|
||
|
boardPowerSlotStatusTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF BoardPowerSlotStatusEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of networking modules installed in this chassis."
|
||
|
::= { boardPower 1 }
|
||
|
|
||
|
boardPowerSlotStatusEntry OBJECT-TYPE
|
||
|
SYNTAX BoardPowerSlotStatusEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A slot entry containing objects for a particular
|
||
|
module."
|
||
|
INDEX { boardPowerSlotStatusID }
|
||
|
::= { boardPowerSlotStatusTable 1 }
|
||
|
|
||
|
BoardPowerSlotStatusEntry ::=
|
||
|
SEQUENCE {
|
||
|
boardPowerSlotStatusID
|
||
|
INTEGER,
|
||
|
boardPowerOperationalStatus
|
||
|
INTEGER,
|
||
|
boardPowerAdminStatus
|
||
|
INTEGER,
|
||
|
boardPowerLocalAdminStatus
|
||
|
INTEGER,
|
||
|
boardPowerLocalStatus
|
||
|
INTEGER,
|
||
|
boardPowerShutdownAdmin
|
||
|
INTEGER,
|
||
|
boardPowerPriority
|
||
|
INTEGER,
|
||
|
boardPowerMaxInputPower
|
||
|
INTEGER,
|
||
|
boardPowerManagement
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
boardPowerSlotStatusID OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The slot number of a chassis slot in which this board is
|
||
|
installed. This object is similiar to chSlotID in the
|
||
|
Chassis MIB."
|
||
|
::= { boardPowerSlotStatusEntry 1 }
|
||
|
|
||
|
boardPowerOperationalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
powerOn(1),
|
||
|
powerOff(2),
|
||
|
reset(3),
|
||
|
overVoltage(4),
|
||
|
underVoltage(5),
|
||
|
overCurrent(6),
|
||
|
overCurrentShutdown(7),
|
||
|
temperatureShutdown(8),
|
||
|
remotePowerOff(9),
|
||
|
powerConservationShutdown(10),
|
||
|
frontPanelPowerOff(11)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object reflects the status of the module's
|
||
|
DC-DC converter power supply."
|
||
|
::= { boardPowerSlotStatusEntry 2 }
|
||
|
|
||
|
boardPowerAdminStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
powerOn(1),
|
||
|
powerOff(2),
|
||
|
reset(3)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object controls the operation of the module's
|
||
|
DC-DC power supply. If the value 3 is written to
|
||
|
this object then the value of the object will be
|
||
|
set to 1 after the reset is performed."
|
||
|
DEFVAL { powerOn }
|
||
|
::= { boardPowerSlotStatusEntry 3 }
|
||
|
|
||
|
boardPowerLocalAdminStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
localMode(1),
|
||
|
secureMode(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object controls the operation of the module's
|
||
|
front panel button. In local mode this button may
|
||
|
be used to locally control the operation of the
|
||
|
DC-DC converter, i.e. power on, power off and
|
||
|
reset. In secure mode a request the state of the
|
||
|
front panel button is reflected in the object
|
||
|
boardPowerOperationalStatus. In secure mode
|
||
|
the front panel button has no effect locally."
|
||
|
DEFVAL { localMode }
|
||
|
::= { boardPowerSlotStatusEntry 4 }
|
||
|
|
||
|
boardPowerLocalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
resetRequest(1),
|
||
|
powerDownRequest(2),
|
||
|
powerOnRequest(3),
|
||
|
normal(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object reflects the state of the module's front
|
||
|
panel button."
|
||
|
::= { boardPowerSlotStatusEntry 5 }
|
||
|
|
||
|
boardPowerShutdownAdmin OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
enabled(1),
|
||
|
disabled(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object controls whether or not the module should
|
||
|
auto power down due to an fault condition."
|
||
|
DEFVAL { disabled }
|
||
|
::= { boardPowerSlotStatusEntry 6 }
|
||
|
|
||
|
boardPowerPriority OBJECT-TYPE
|
||
|
SYNTAX INTEGER (1..14)
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The module's power-up and power down priority. This is a
|
||
|
value of 1 to 14 and is used to decide which modules are
|
||
|
allowed to power on in the event that power demand of the
|
||
|
chassis is greater than the total power supply. The default
|
||
|
value is 14, highest priority. When two modules have equal
|
||
|
priority then the module in the lowest slot wins."
|
||
|
DEFVAL { 14 }
|
||
|
::= { boardPowerSlotStatusEntry 7 }
|
||
|
|
||
|
boardPowerMaxInputPower OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum input power that this module is allowed
|
||
|
to consume. The value of this object is actual
|
||
|
watts."
|
||
|
::= { boardPowerSlotStatusEntry 8 }
|
||
|
|
||
|
boardPowerManagement OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
disabled(1),
|
||
|
enabled(2),
|
||
|
not-supported(7)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Module power management status."
|
||
|
DEFVAL { not-supported }
|
||
|
::= { boardPowerSlotStatusEntry 9 }
|
||
|
|
||
|
boardPowerSlotTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF BoardPowerSlotEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of networking modules and associated power lines
|
||
|
installed in this chassis."
|
||
|
::= { boardPower 2 }
|
||
|
|
||
|
boardPowerSlotEntry OBJECT-TYPE
|
||
|
SYNTAX BoardPowerSlotEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A slot entry containing objects for a particular
|
||
|
module and associated power line."
|
||
|
INDEX { boardPowerSlotID, boardPowerID }
|
||
|
::= { boardPowerSlotTable 1 }
|
||
|
|
||
|
BoardPowerSlotEntry ::=
|
||
|
SEQUENCE {
|
||
|
boardPowerSlotID
|
||
|
INTEGER,
|
||
|
boardPowerID
|
||
|
INTEGER,
|
||
|
boardPowerType
|
||
|
OBJECT IDENTIFIER,
|
||
|
boardPowerStatus
|
||
|
INTEGER,
|
||
|
boardPowerVoltage
|
||
|
INTEGER,
|
||
|
boardPowerCurrent
|
||
|
INTEGER,
|
||
|
boardPowerMaxVoltage
|
||
|
INTEGER,
|
||
|
boardPowerMinVoltage
|
||
|
INTEGER,
|
||
|
boardPowerMaxPower
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
boardPowerSlotID OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The slot number of a chassis slot in which this board is
|
||
|
installed. This object is similiar to chSlotID in the
|
||
|
Chassis MIB."
|
||
|
::= { boardPowerSlotEntry 1 }
|
||
|
|
||
|
boardPowerID OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A unique value used to identify a particular power line."
|
||
|
::= { boardPowerSlotEntry 2 }
|
||
|
|
||
|
boardPowerType OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The type of power. For example, a power line that supplies
|
||
|
DC current at a nominal voltage of 40 to 57 volts or a
|
||
|
power line that supplies AC current at a nominal volatge of
|
||
|
110v."
|
||
|
::= { boardPowerSlotEntry 3 }
|
||
|
|
||
|
boardPowerStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
powerOK(1),
|
||
|
powerOff(2),
|
||
|
overCurrent(3),
|
||
|
overVoltage(4),
|
||
|
underVoltage(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object reflects the status of this power line."
|
||
|
::= { boardPowerSlotEntry 4 }
|
||
|
|
||
|
boardPowerVoltage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The voltage reading for the power line. The value of this
|
||
|
object is actual voltage * 100."
|
||
|
::= { boardPowerSlotEntry 5 }
|
||
|
|
||
|
boardPowerCurrent OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current reading for the power line. The value of this
|
||
|
object is the actual amperage * 100. If this reading is not
|
||
|
implemented then value will be zero."
|
||
|
::= { boardPowerSlotEntry 6 }
|
||
|
|
||
|
boardPowerMaxVoltage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum voltage for this power line. If the voltage
|
||
|
reading for this power line is greater than this value
|
||
|
then the power line is considered to be in an overvolatge
|
||
|
condition. The value of this object is in voltage * 100."
|
||
|
::= { boardPowerSlotEntry 7 }
|
||
|
|
||
|
boardPowerMinVoltage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The minimum voltage for this power line. If the voltage
|
||
|
reading for this power line is less than this value
|
||
|
then the power line is considered to be in an undervolatge
|
||
|
condition. The value of this object is voltage * 100."
|
||
|
::= { boardPowerSlotEntry 8 }
|
||
|
|
||
|
boardPowerMaxPower OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum power for this power line. If the power calculated
|
||
|
for this power line is greater than this value then the
|
||
|
power line is considered to be in an overload condition.
|
||
|
The value of this object is in watts."
|
||
|
::= { boardPowerSlotEntry 9 }
|
||
|
|
||
|
--=============== psPower group ====================
|
||
|
|
||
|
-- AC and DC Power Supply Power Group
|
||
|
-- This group covers information on the use of power within the
|
||
|
-- chassis by the networking boards.
|
||
|
|
||
|
psPowerSlotStatusTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PsPowerSlotStatusEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of AC & DC power supplies installed in this chassis."
|
||
|
::= { psPower 1 }
|
||
|
|
||
|
psPowerSlotStatusEntry OBJECT-TYPE
|
||
|
SYNTAX PsPowerSlotStatusEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A slot entry containing objects for a particular
|
||
|
power supply."
|
||
|
INDEX { psPowerSlotStatusID }
|
||
|
::= { psPowerSlotStatusTable 1 }
|
||
|
|
||
|
PsPowerSlotStatusEntry ::=
|
||
|
SEQUENCE {
|
||
|
psPowerSlotStatusID
|
||
|
INTEGER,
|
||
|
psPowerOperationalStatus
|
||
|
INTEGER,
|
||
|
psPowerAdminStatus
|
||
|
INTEGER,
|
||
|
psPowerMaxOutputPower
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
psPowerSlotStatusID OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The slot number of a chassis slot in which this AC power
|
||
|
supply is installed. This object is similiar
|
||
|
to chSlotID in the Chassis MIB."
|
||
|
::= { psPowerSlotStatusEntry 1 }
|
||
|
|
||
|
psPowerOperationalStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
powerOn(1),
|
||
|
powerOff(2),
|
||
|
reset(3),
|
||
|
overVoltage(4),
|
||
|
underVoltage(5),
|
||
|
overCurrent(6),
|
||
|
overCurrentShutdown(7),
|
||
|
temperatureShutdown(8),
|
||
|
remotePowerOff(9)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object reflects the status of the module's
|
||
|
DC-DC converter power supply."
|
||
|
::= { psPowerSlotStatusEntry 2 }
|
||
|
|
||
|
psPowerAdminStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
powerOn(1),
|
||
|
powerOff(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object controls the operation of power supply."
|
||
|
DEFVAL { powerOn }
|
||
|
::= { psPowerSlotStatusEntry 3 }
|
||
|
|
||
|
psPowerMaxOutputPower OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum power that this power supply is allowed
|
||
|
to ouput. The value of this object is watts."
|
||
|
::= { psPowerSlotStatusEntry 4 }
|
||
|
|
||
|
psPowerSlotTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF PsPowerSlotEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of power supplies and associated power lines
|
||
|
installed in this chassis."
|
||
|
::= { psPower 2 }
|
||
|
|
||
|
psPowerSlotEntry OBJECT-TYPE
|
||
|
SYNTAX PsPowerSlotEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A slot entry containing objects for a particular
|
||
|
power line on a particular power supply."
|
||
|
INDEX { psPowerSlotID, psPowerID }
|
||
|
::= { psPowerSlotTable 1 }
|
||
|
|
||
|
PsPowerSlotEntry ::=
|
||
|
SEQUENCE {
|
||
|
psPowerSlotID
|
||
|
INTEGER,
|
||
|
psPowerID
|
||
|
INTEGER,
|
||
|
psPowerType
|
||
|
OBJECT IDENTIFIER,
|
||
|
psPowerStatus
|
||
|
INTEGER,
|
||
|
psPowerAdmin
|
||
|
INTEGER,
|
||
|
psPowerVoltage
|
||
|
INTEGER,
|
||
|
psPowerCurrent
|
||
|
INTEGER,
|
||
|
psPowerLineFrequency
|
||
|
INTEGER,
|
||
|
psPowerMaxVoltage
|
||
|
INTEGER,
|
||
|
psPowerMinVoltage
|
||
|
INTEGER,
|
||
|
psPowerMaxPower
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
psPowerSlotID OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The slot number of a chassis slot in which this Power
|
||
|
supply is installed. This object is similiar to
|
||
|
chSlotID in the Chassis MIB."
|
||
|
::= { psPowerSlotEntry 1 }
|
||
|
|
||
|
psPowerID OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A unique value used to identify a particular power line."
|
||
|
::= { psPowerSlotEntry 2 }
|
||
|
|
||
|
psPowerType OBJECT-TYPE
|
||
|
SYNTAX OBJECT IDENTIFIER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The type of power. For example, a power line that supplies
|
||
|
DC current at a nominal voltage of 40 to 57 volts or a
|
||
|
power line that supplies AC current at a nominal volatge of
|
||
|
110v."
|
||
|
::= { psPowerSlotEntry 3 }
|
||
|
|
||
|
psPowerStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
powerOK(1),
|
||
|
powerOff(2),
|
||
|
overCurrent(3),
|
||
|
overVoltage(4),
|
||
|
underVoltage(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object reflects the status of the power line."
|
||
|
::= { psPowerSlotEntry 4 }
|
||
|
|
||
|
psPowerAdmin OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
powerOn(1),
|
||
|
powerOff(2)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object controls the operation of power supply."
|
||
|
DEFVAL { powerOn }
|
||
|
::= { psPowerSlotEntry 5 }
|
||
|
|
||
|
psPowerVoltage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The voltage reading for the power line. The value of this
|
||
|
object is the actual voltage * 100."
|
||
|
::= { psPowerSlotEntry 6 }
|
||
|
|
||
|
psPowerCurrent OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current reading for the power line. The value of this
|
||
|
object is amperage * 100. If this reading is not implemented
|
||
|
then value will be zero."
|
||
|
::= { psPowerSlotEntry 7 }
|
||
|
|
||
|
psPowerLineFrequency OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The line frequency for the power line. The value of this
|
||
|
object is the actual frequency in Hertz * 10. If this
|
||
|
reading is not implemented then value will be zero."
|
||
|
::= { psPowerSlotEntry 8 }
|
||
|
|
||
|
psPowerMaxVoltage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum voltage for this power line. If the voltage
|
||
|
reading for this power line is greater than this value
|
||
|
then the power line is considered to be in an over volatge
|
||
|
condition. The value of this object is voltage * 100."
|
||
|
::= { psPowerSlotEntry 9 }
|
||
|
|
||
|
psPowerMinVoltage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The minimum voltage for this power line. If the voltage
|
||
|
reading for this power line is greater than this value
|
||
|
then the power line is considered to be in an over volatge
|
||
|
condition. The value of this object is voltage * 100."
|
||
|
::= { psPowerSlotEntry 10 }
|
||
|
|
||
|
psPowerMaxPower OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum power for this power line. If the power calculated
|
||
|
for this power line is greater than this value then the
|
||
|
power line is considered to be in an overload condition.
|
||
|
The value of this object is watts."
|
||
|
::= { psPowerSlotEntry 11 }
|
||
|
|
||
|
--=============== bbuPower group ====================
|
||
|
|
||
|
-- Battery Backup Unit Power Group
|
||
|
-- This group covers information on the use of power within the
|
||
|
-- chassis by the battery backup unit.
|
||
|
|
||
|
--=============== termPower group ====================
|
||
|
|
||
|
-- INB Termination Module Power Group
|
||
|
-- This group covers information on the use of power within the
|
||
|
-- chassis by the INB termination modules.
|
||
|
|
||
|
termPowerStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
powerOK(1),
|
||
|
overCurrent(2),
|
||
|
overVoltage(3),
|
||
|
underVolatge(4),
|
||
|
overPower(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object reflects the status of the chassis's termination
|
||
|
voltage rail."
|
||
|
::= { termPower 1 }
|
||
|
|
||
|
termPowerVoltage OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The voltage of the chassis's termination voltage rail.
|
||
|
This rail carries power to INB terminator cards in the
|
||
|
chassis. It has an allowalble range of 3.3 Volt + or -
|
||
|
5%.The value of this object is voltage * 100."
|
||
|
::= { termPower 2 }
|
||
|
|
||
|
termPowerCurrent OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current on the chassis's termination voltage rail.
|
||
|
The value of this object is the actual amperage * 100.
|
||
|
If this reading is not implemented then the value will
|
||
|
be zero."
|
||
|
::= { termPower 3 }
|
||
|
|
||
|
termPowerModule1Status OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
normal(1),
|
||
|
iNBaFault(2),
|
||
|
iNBbFault(3),
|
||
|
fault(4),
|
||
|
termModuleNotInstalled(5),
|
||
|
unknown(6)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object reflects the state of the INB termination
|
||
|
module number 1. A value of normal(1) reflects that
|
||
|
both busses are normal. A value of fault(4) reflects
|
||
|
that both busses are in a fault condition."
|
||
|
::= { termPower 4 }
|
||
|
|
||
|
termPowerModule2Status OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
normal(1),
|
||
|
iNBaFault(2),
|
||
|
iNBbFault(3),
|
||
|
fault(4),
|
||
|
termModuleNotInstalled(5),
|
||
|
unknown(6)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This object reflects the state of the INB termination
|
||
|
module number 2. A value of normal(1) reflects that
|
||
|
both busses are normal. A value of fault(4) reflects
|
||
|
that both busses are in a fault condition."
|
||
|
::= { termPower 5 }
|
||
|
|
||
|