269 lines
6.7 KiB
Plaintext
269 lines
6.7 KiB
Plaintext
|
--
|
||
|
-- MODULE-IDENTITY
|
||
|
-- OrgName
|
||
|
-- Fortinet, Inc.
|
||
|
-- ContactInfo
|
||
|
-- Technical Support
|
||
|
-- e-mail: support@fortinet.com
|
||
|
-- http://www.fortinet.com
|
||
|
--
|
||
|
|
||
|
FORTINET-FORTIVOICE-MIB DEFINITIONS ::= BEGIN
|
||
|
IMPORTS
|
||
|
MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
|
||
|
FROM SNMPv2-CONF
|
||
|
DisplayString, TEXTUAL-CONVENTION
|
||
|
FROM SNMPv2-TC
|
||
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Gauge32,
|
||
|
IpAddress
|
||
|
FROM SNMPv2-SMI
|
||
|
ifIndex
|
||
|
FROM IF-MIB
|
||
|
FnBoolState, FnIndex, FnSessionProto, fortinet
|
||
|
FROM FORTINET-CORE-MIB;
|
||
|
|
||
|
fnFortiVoiceMib MODULE-IDENTITY
|
||
|
LAST-UPDATED "201401300000Z"
|
||
|
ORGANIZATION
|
||
|
"Fortinet Technologies, Inc."
|
||
|
CONTACT-INFO
|
||
|
"Technical Support
|
||
|
email: support@fortinet.com
|
||
|
http://www.fortinet.com
|
||
|
"
|
||
|
DESCRIPTION
|
||
|
"Inherit FORTINET-CORE-MIB, combine FortiVoice traps"
|
||
|
REVISION "201401300000Z"
|
||
|
DESCRIPTION
|
||
|
"MIB module for FortiVoice devices."
|
||
|
::= { fortinet 115 }
|
||
|
|
||
|
--
|
||
|
-- Textual conventions --
|
||
|
--
|
||
|
|
||
|
FvSysEventCodeVal ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"enumerated type for System component events."
|
||
|
SYNTAX INTEGER {
|
||
|
systemHalt (1),
|
||
|
systemReboot (2),
|
||
|
systemReload (3),
|
||
|
systemUpgrade (4),
|
||
|
guiUpgrade (5),
|
||
|
logDiskFormat (6),
|
||
|
storageDiskFormat (7)
|
||
|
}
|
||
|
|
||
|
FvHAEventIdVal ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"enumerated type for HA events."
|
||
|
SYNTAX INTEGER {
|
||
|
masterUnitSwitch (1),
|
||
|
slaveUnitSwitch (2),
|
||
|
unitShutdown (3)
|
||
|
}
|
||
|
|
||
|
FvHAModeVal ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"enumerated type for HA mode."
|
||
|
SYNTAX INTEGER {
|
||
|
off (0),
|
||
|
master (1),
|
||
|
slave (2)
|
||
|
}
|
||
|
|
||
|
|
||
|
--
|
||
|
--
|
||
|
--
|
||
|
|
||
|
fvTraps OBJECT IDENTIFIER ::= { fnFortiVoiceMib 0 }
|
||
|
fvSystem OBJECT IDENTIFIER ::= { fnFortiVoiceMib 1 }
|
||
|
fvSysHA OBJECT IDENTIFIER ::= { fvSystem 200 }
|
||
|
fvMIBConformance OBJECT IDENTIFIER ::= { fnFortiVoiceMib 600 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- fnFortiVoiceMib.fvSystem
|
||
|
--
|
||
|
|
||
|
fvSysModel OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION "System model string"
|
||
|
::= { fvSystem 1 }
|
||
|
|
||
|
fvSysSerial OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION "Device serial number"
|
||
|
::= { fvSystem 2 }
|
||
|
|
||
|
fvSysVersion OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 128 ) )
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION "Device firmware version"
|
||
|
::= { fvSystem 3 }
|
||
|
|
||
|
fvSysCpuUsage OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION "Instantaneous CPU usage"
|
||
|
::= { fvSystem 6 }
|
||
|
|
||
|
fvSysMemUsage OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION "Instantaneous memory utilization"
|
||
|
::= { fvSystem 7 }
|
||
|
|
||
|
fvSysLogDiskUsage OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION "Instantaneous log disk usage"
|
||
|
::= { fvSystem 8 }
|
||
|
|
||
|
fvSysStorageDiskUsage OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION "Instantaneous storage disk usage"
|
||
|
::= { fvSystem 9 }
|
||
|
|
||
|
fvSysEventCode OBJECT-TYPE
|
||
|
SYNTAX FvSysEventCodeVal
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION "System component events"
|
||
|
::= { fvSystem 11 }
|
||
|
|
||
|
fvHAEventId OBJECT-TYPE
|
||
|
SYNTAX FvHAEventIdVal
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION "HA event type ID"
|
||
|
::= { fvSystem 14 }
|
||
|
|
||
|
fvHAUnitIp OBJECT-TYPE
|
||
|
SYNTAX IpAddress
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION "Unit IP address where event occurs "
|
||
|
::= { fvSystem 15 }
|
||
|
|
||
|
fvHAEventReason OBJECT-TYPE
|
||
|
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION "The reason for the HA event"
|
||
|
::= { fvSystem 16 }
|
||
|
|
||
|
fvSysLoad OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION "Instantaneous system load"
|
||
|
::= { fvSystem 30 }
|
||
|
|
||
|
--
|
||
|
-- fnFortiVoiceMib.fvSystem.fvSysHA
|
||
|
--
|
||
|
|
||
|
fvHAMode OBJECT-TYPE
|
||
|
SYNTAX FvHAModeVal
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION "Configured HA mode"
|
||
|
::= { fvSysHA 1 }
|
||
|
|
||
|
fvHAEffectiveMode OBJECT-TYPE
|
||
|
SYNTAX FvHAModeVal
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION "Effective HA mode"
|
||
|
::= { fvSysHA 2 }
|
||
|
|
||
|
--
|
||
|
-- fnFortiVoiceMib.fvTraps
|
||
|
--
|
||
|
|
||
|
fvTrapStorageDiskHighThreshold NOTIFICATION-TYPE
|
||
|
OBJECTS { fvSysSerial}
|
||
|
STATUS current
|
||
|
DESCRIPTION "Trap being sent if the storage disk usage becomes too high"
|
||
|
::= { fvTraps 104 }
|
||
|
|
||
|
fvTrapSystemEvent NOTIFICATION-TYPE
|
||
|
OBJECTS { fvSysSerial, fvSysEventCode }
|
||
|
STATUS current
|
||
|
DESCRIPTION "Trap being sent when the system component halt, reboot, upgrade etc.,"
|
||
|
::= { fvTraps 201 }
|
||
|
|
||
|
fvTrapHAEvent NOTIFICATION-TYPE
|
||
|
OBJECTS { fvSysSerial, fvHAEventId, fvHAUnitIp, fvHAEventReason }
|
||
|
STATUS current
|
||
|
DESCRIPTION "Trap being sent when HA event occurs"
|
||
|
::= { fvTraps 203 }
|
||
|
|
||
|
--
|
||
|
-- fnFortiVoiceMib.fvMIBConformance
|
||
|
--
|
||
|
|
||
|
fvSystemConformanceGroup OBJECT-GROUP
|
||
|
OBJECTS { fvSysModel, fvSysSerial, fvSysVersion, fvSysCpuUsage, fvSysMemUsage,
|
||
|
fvSysLogDiskUsage, fvSysStorageDiskUsage, fvSysEventCode, fvSysLoad }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"object related to fortivoice system."
|
||
|
::= { fvMIBConformance 1 }
|
||
|
|
||
|
fvHAModeConformanceGroup OBJECT-GROUP
|
||
|
OBJECTS { fvHAMode, fvHAEffectiveMode }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"object related to fortivoice HA mode."
|
||
|
::= { fvMIBConformance 6 }
|
||
|
|
||
|
fvTrapsComplianceGroup NOTIFICATION-GROUP
|
||
|
NOTIFICATIONS {
|
||
|
fvTrapStorageDiskHighThreshold,
|
||
|
fvTrapSystemEvent,
|
||
|
fvTrapHAEvent
|
||
|
}
|
||
|
STATUS current
|
||
|
DESCRIPTION "Event notifications"
|
||
|
::= { fvMIBConformance 7 }
|
||
|
|
||
|
fvMIBCompliance MODULE-COMPLIANCE
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"the compliance statement for the application MIB."
|
||
|
|
||
|
MODULE -- this module
|
||
|
|
||
|
GROUP fvSystemConformanceGroup
|
||
|
DESCRIPTION
|
||
|
"this group is mandatory for all FortiVoice appliances supporting this MIB."
|
||
|
|
||
|
GROUP fvHAModeConformanceGroup
|
||
|
DESCRIPTION
|
||
|
"this group is mandatory for all FortiVoice appliances supporting this MIB."
|
||
|
|
||
|
GROUP fvTrapsComplianceGroup
|
||
|
DESCRIPTION
|
||
|
"this group is mandatory for all FortiVoice appliances supporting this MIB."
|
||
|
|
||
|
::= { fvMIBConformance 100 }
|
||
|
|
||
|
END
|