814 lines
26 KiB
Plaintext
814 lines
26 KiB
Plaintext
|
GIGAMON-SNMP-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
--
|
||
|
-- Gigamon MIB objects for agent module
|
||
|
--
|
||
|
|
||
|
IMPORTS
|
||
|
MODULE-IDENTITY, OBJECT-TYPE, enterprises, Integer32, Unsigned32,
|
||
|
NOTIFICATION-TYPE FROM SNMPv2-SMI
|
||
|
sysLocation FROM RFC1213-MIB
|
||
|
TEXTUAL-CONVENTION, DisplayString,
|
||
|
PhysAddress, TimeStamp FROM SNMPv2-TC;
|
||
|
|
||
|
gigamonSnmp MODULE-IDENTITY
|
||
|
LAST-UPDATED "201805150000Z"
|
||
|
ORGANIZATION "www.gigamon.com"
|
||
|
CONTACT-INFO
|
||
|
"postal: Gigamon LLC
|
||
|
598 Gibraltar Drive
|
||
|
Milpitas, CA 95035
|
||
|
|
||
|
email: support@gigamon.com"
|
||
|
DESCRIPTION
|
||
|
"Top-level infrastructure of Gigamon's MIB objects for
|
||
|
GigaVUE-212, GigaVUE-420, GigaVUE-2404,
|
||
|
GigaVUE-HD and GigaVUE-TA1"
|
||
|
|
||
|
-- HISTORY
|
||
|
REVISION "201805150000Z"
|
||
|
DESCRIPTION
|
||
|
" Fixed smilint errors"
|
||
|
|
||
|
REVISION "201309250000Z"
|
||
|
DESCRIPTION
|
||
|
"Added powerSupply OID to gigamonSystem MIB group"
|
||
|
|
||
|
REVISION "201304150000Z"
|
||
|
DESCRIPTION
|
||
|
"Added 'license-mismatch' to gigamonSnmpNotifModuleOperationType"
|
||
|
|
||
|
REVISION "201212040000Z"
|
||
|
DESCRIPTION
|
||
|
"Added 'up' to gigamonSnmpNotifModuleOperationType"
|
||
|
|
||
|
REVISION "201205090000Z"
|
||
|
DESCRIPTION
|
||
|
"Added new information found under gigamonSystem MIB group
|
||
|
1) Updated GigaVUE product line support:
|
||
|
(a) Added GigaVUE-TA1
|
||
|
(b) Removed G-TAP and GigaVUE-MP
|
||
|
2) Added speed40000 and speed100000 in gigamonSnmpPortLinkSpeed
|
||
|
for representing 40G and 100G port speed"
|
||
|
|
||
|
REVISION "201203270000Z"
|
||
|
DESCRIPTION
|
||
|
"Added 'shutdown' to gigamonSnmpNotifModuleOperationType"
|
||
|
|
||
|
REVISION "201103250000Z"
|
||
|
DESCRIPTION
|
||
|
"Added the following notifications:
|
||
|
- gigamonSnmpCpuUtilHighNotification
|
||
|
- gigamonSnmpUnexpectedShutdownNotification
|
||
|
- gigamonSnmpDiskSpaceLowNotification"
|
||
|
|
||
|
REVISION "201103240000Z"
|
||
|
DESCRIPTION
|
||
|
"Added G-TAP support"
|
||
|
|
||
|
REVISION "201103030000Z"
|
||
|
DESCRIPTION
|
||
|
"Added GigaVUE-HD support"
|
||
|
|
||
|
REVISION "201007101000Z"
|
||
|
DESCRIPTION
|
||
|
"Created notification definitions. First draft"
|
||
|
|
||
|
::= { enterprises 26866 }
|
||
|
|
||
|
--
|
||
|
-- Gigamon's enterprise-specific management objects
|
||
|
--
|
||
|
-- top level structure
|
||
|
--
|
||
|
-- GigaVUE product line - GigaVUE-212, GigaVUE-420, GigaVUE-2404,
|
||
|
-- GigaVUE-HD, GigaVUE-TA1
|
||
|
gigamonSnmpNotifications OBJECT IDENTIFIER ::= { gigamonSnmp 1 }
|
||
|
gigamonGigaVUE OBJECT IDENTIFIER ::= { gigamonSnmpNotifications 1 }
|
||
|
gigamonSnmpNotificationObjects OBJECT IDENTIFIER
|
||
|
::= { gigamonSnmpNotifications 2 }
|
||
|
|
||
|
gigamonSystem OBJECT IDENTIFIER ::= { gigamonSnmp 2 }
|
||
|
|
||
|
------------------------------------------
|
||
|
-- System Information
|
||
|
------------------------------------------
|
||
|
manufacturer OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the manufacturer name of the system."
|
||
|
::= { gigamonSystem 1 }
|
||
|
|
||
|
model OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the model name of the system."
|
||
|
::= { gigamonSystem 2 }
|
||
|
|
||
|
name OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the name of the system."
|
||
|
::= { gigamonSystem 3 }
|
||
|
|
||
|
serialNumber OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the serial number of the system."
|
||
|
::= { gigamonSystem 4 }
|
||
|
|
||
|
systemDescription OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the description of the system."
|
||
|
::= { gigamonSystem 5 }
|
||
|
|
||
|
version OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the software version of the system."
|
||
|
::= { gigamonSystem 6 }
|
||
|
|
||
|
chassisModelNumber OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the chassis model number of the system."
|
||
|
::= { gigamonSystem 7 }
|
||
|
|
||
|
chassisSerialNumber OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the chassis serial number of the system."
|
||
|
::= { gigamonSystem 8 }
|
||
|
|
||
|
bladeSerialNumbers OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the blade serial numbers in the system."
|
||
|
::= { gigamonSystem 9 }
|
||
|
|
||
|
firmwareVersion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the firmware version of the system."
|
||
|
::= { gigamonSystem 10 }
|
||
|
|
||
|
hardwareVersion OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the hardware version of the system."
|
||
|
::= { gigamonSystem 11 }
|
||
|
|
||
|
cpuRAMSize OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the CPU RAM size of the system."
|
||
|
::= { gigamonSystem 12 }
|
||
|
|
||
|
cpuUtilization OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the CPU utilization of the system."
|
||
|
::= { gigamonSystem 13 }
|
||
|
|
||
|
fans OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the fans in the system."
|
||
|
::= { gigamonSystem 14 }
|
||
|
|
||
|
temperatureSensors OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the temperature sensors in the system."
|
||
|
::= { gigamonSystem 15 }
|
||
|
|
||
|
powerSupply OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Displays the power supplies in the system."
|
||
|
::= { gigamonSystem 16 }
|
||
|
|
||
|
----
|
||
|
|
||
|
-- Product Type Information
|
||
|
gigamonProducts OBJECT IDENTIFIER ::= { gigamonSnmp 3 }
|
||
|
gigamonGV2404 OBJECT IDENTIFIER ::= { gigamonProducts 1 }
|
||
|
gigamonGV420 OBJECT IDENTIFIER ::= { gigamonProducts 2 }
|
||
|
gigamonGV212 OBJECT IDENTIFIER ::= { gigamonProducts 3 }
|
||
|
gigamonGV216 OBJECT IDENTIFIER ::= { gigamonProducts 4 }
|
||
|
|
||
|
----
|
||
|
|
||
|
------------------------------------------
|
||
|
-- Objects used in Gigamon Notifications
|
||
|
------------------------------------------
|
||
|
gigamonSnmpNotifLevel OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
information(1),
|
||
|
minor(2),
|
||
|
major(3),
|
||
|
critical(4)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"It acts as a payload for the level of Gigamon's Notifications."
|
||
|
::= { gigamonSnmpNotificationObjects 1 }
|
||
|
|
||
|
gigamonSnmpNotifDescription OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"It acts as a payload for the description of Gigamon's Notifications.
|
||
|
The value is to describe the reason for the notification."
|
||
|
::= { gigamonSnmpNotificationObjects 2 }
|
||
|
|
||
|
gigamonSnmpNotifOpType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
read(1),
|
||
|
write(2),
|
||
|
delete(3),
|
||
|
validate(4),
|
||
|
change(5)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"It specifies the type of operation of Gigamon's Notifications."
|
||
|
::= { gigamonSnmpNotificationObjects 3 }
|
||
|
|
||
|
gigamonSnmpNotifPortName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The alpha-numerical name of a port shown in Gigamon's Notifications."
|
||
|
::= { gigamonSnmpNotificationObjects 4 }
|
||
|
|
||
|
gigamonSnmpNotifPortLinkStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
down(0),
|
||
|
up(1)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"It indicates port link status of Gigamon's Notifications."
|
||
|
::= { gigamonSnmpNotificationObjects 5 }
|
||
|
|
||
|
gigamonSnmpNotifTAPRelayStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
none(0),
|
||
|
passive(1),
|
||
|
active(2)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"It indicates TAP relay status of Gigamon's Notifications."
|
||
|
::= { gigamonSnmpNotificationObjects 6 }
|
||
|
|
||
|
gigamonSnmpNotifRxTxType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
rx(0),
|
||
|
tx(1)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"It indicates Incoming/RX or outgoing/TX packets"
|
||
|
::= { gigamonSnmpNotificationObjects 7 }
|
||
|
|
||
|
gigamonSnmpNotifRxTxErrorType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
under-size(0),
|
||
|
fragments(1),
|
||
|
obsolete(2),
|
||
|
jabbers(3),
|
||
|
crc-align(4),
|
||
|
unknown(5)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"It indicates RX/TX error type of Gigamon's Notifications."
|
||
|
::= { gigamonSnmpNotificationObjects 8 }
|
||
|
|
||
|
gigamonSnmpNotifCounter OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"32-bit Counter."
|
||
|
::= { gigamonSnmpNotificationObjects 9 }
|
||
|
|
||
|
gigamonSnmpNotifFirmwareName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Name of GigaVUE firmware."
|
||
|
::= { gigamonSnmpNotificationObjects 10 }
|
||
|
|
||
|
gigamonSnmpNotifModuleOperationType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
removed(0),
|
||
|
inserted(1),
|
||
|
changed(2),
|
||
|
mismatch(3),
|
||
|
shutdown(4),
|
||
|
up(5),
|
||
|
license-mismatch(6)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"It indicates the operation performed on module"
|
||
|
::= { gigamonSnmpNotificationObjects 11 }
|
||
|
|
||
|
gigamonSnmpNotifModuleName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Module name of GigaVUE module"
|
||
|
::= { gigamonSnmpNotificationObjects 12 }
|
||
|
|
||
|
gigamonNotifSlotNumber OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
mid-plane(0),
|
||
|
slot-1(1),
|
||
|
slot-2(2),
|
||
|
slot-3(3),
|
||
|
gigaLink-Back(4),
|
||
|
daughter-Card(5),
|
||
|
slot-4(10),
|
||
|
slot-5(11),
|
||
|
slot-6(12),
|
||
|
slot-7(13),
|
||
|
slot-8(14),
|
||
|
slot-CC1(15),
|
||
|
slot-CC2(16)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Slot number"
|
||
|
::= { gigamonSnmpNotificationObjects 13 }
|
||
|
|
||
|
gigamonSnmpNotifUserName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"User login name typed in"
|
||
|
::= { gigamonSnmpNotificationObjects 14 }
|
||
|
|
||
|
gigamonSnmpNotifFileName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Saved configuration file name"
|
||
|
::= { gigamonSnmpNotificationObjects 15 }
|
||
|
|
||
|
gigamonNotifPowerStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
failure(-1),
|
||
|
abnormal(0),
|
||
|
normal(1)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Power Status"
|
||
|
::= { gigamonSnmpNotificationObjects 16 }
|
||
|
|
||
|
gigamonSnmpNotifHardWareName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Description of Hardware"
|
||
|
::= { gigamonSnmpNotificationObjects 17 }
|
||
|
|
||
|
gigamonSnmpNotifGigaVUE420SlotNumber OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
mid-plane(0),
|
||
|
expansion-slot-1(1),
|
||
|
expansion-slot-2(2),
|
||
|
expansion-slot-3(3),
|
||
|
expansion-slot-4(4),
|
||
|
expansion-slot-5(5),
|
||
|
x1-slot(6),
|
||
|
x2-slot(7),
|
||
|
x3-slot(8),
|
||
|
x4-slot(9)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Slot number"
|
||
|
::= { gigamonSnmpNotificationObjects 18 }
|
||
|
|
||
|
gigamonSnmpNotifFanName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Name of fan"
|
||
|
::= { gigamonSnmpNotificationObjects 19 }
|
||
|
|
||
|
gigamonNotifFanStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
failure(-1),
|
||
|
abnormal(0),
|
||
|
normal(1)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Fan Status"
|
||
|
::= { gigamonSnmpNotificationObjects 20 }
|
||
|
|
||
|
gigamonSnmpNotifUtilizationAlarm OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
below(0),
|
||
|
exceed(1)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"It indicates over-threshold port utilization alarm of Gigamon's Notifications."
|
||
|
::= { gigamonSnmpNotificationObjects 21 }
|
||
|
|
||
|
gigamonSnmpNotifUtilizationThreshold OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Utilization threshold percentage"
|
||
|
::= { gigamonSnmpNotificationObjects 22 }
|
||
|
|
||
|
gigamonSnmpBatteryLevel OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
batteryChargeComplete(0),
|
||
|
downBelow75(1),
|
||
|
downBelow50(2),
|
||
|
downBelow25(3),
|
||
|
shutDownSystem(4)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
" battery level:
|
||
|
0 - battery charge complete
|
||
|
1 - battery level has been down below 75%
|
||
|
2 - battery level has been down below 50%
|
||
|
3 - battery level has been down below 25%
|
||
|
4 - battery level has down to 15% or below and shutting down the system "
|
||
|
::= { gigamonSnmpNotificationObjects 23 }
|
||
|
|
||
|
gigamonSnmpPortLinkSpeed OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
notApply(0),
|
||
|
speed10(1),
|
||
|
speed100(2),
|
||
|
speed1000(3),
|
||
|
speed10000(4),
|
||
|
speed40000(5),
|
||
|
speed100000(6)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
" port link speed:
|
||
|
0 - Not Apply if link is down
|
||
|
1 - 10 Mbps
|
||
|
2 - 100 Mbps
|
||
|
3 - 1000 Mbps
|
||
|
4 - 10000 Mbps
|
||
|
5 - 40000 Mbps
|
||
|
6 - 100000 Mbps "
|
||
|
::= { gigamonSnmpNotificationObjects 24 }
|
||
|
|
||
|
gigamonSnmpPortLinkDuplex OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
notApply(0),
|
||
|
full(1),
|
||
|
half(2)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
" port link duplex:
|
||
|
0 - Not Apply if link is down
|
||
|
1 - full duplex
|
||
|
2 - half duplex "
|
||
|
::= { gigamonSnmpNotificationObjects 25 }
|
||
|
|
||
|
gigamonSnmpNotifCpuIndex OBJECT-TYPE
|
||
|
SYNTAX Unsigned32
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Index of CPU, starting from 0"
|
||
|
::= { gigamonSnmpNotificationObjects 26 }
|
||
|
|
||
|
gigamonSnmpNotifFsMountPoint OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Mount point for this filesystem"
|
||
|
::= { gigamonSnmpNotificationObjects 27 }
|
||
|
|
||
|
gigamonSnmpPowerSource OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
mainPower(0),
|
||
|
poe(1),
|
||
|
power48V(2)
|
||
|
}
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
" power source:
|
||
|
0 - main power
|
||
|
1 - poe(Power over Ethernet)
|
||
|
2 - -48V Power "
|
||
|
::= { gigamonSnmpNotificationObjects 28 }
|
||
|
|
||
|
gigamonSnmpNotifBpsUnitName OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Name of BPS unit"
|
||
|
::= { gigamonSnmpNotificationObjects 29 }
|
||
|
|
||
|
gigamonSnmpNotifBpsFailoverStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
primary(0),
|
||
|
secondary(1)
|
||
|
}
|
||
|
MAX-ACCESS accessible-for-notify
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Inline-bypass active unit change"
|
||
|
::= { gigamonSnmpNotificationObjects 30 }
|
||
|
|
||
|
---------------------------
|
||
|
-- Gigamon Notifications
|
||
|
---------------------------
|
||
|
gigamonSnmpResetSystemNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"System reset notification triggered by cold or warm start."
|
||
|
::= { gigamonGigaVUE 1 }
|
||
|
|
||
|
gigamonSnmpUserAuthFailNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifUserName}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Failure in user login operation is the triggered Event."
|
||
|
::= { gigamonGigaVUE 2 }
|
||
|
|
||
|
gigamonSnmpFirmwareChangeNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifFirmwareName }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Firmware Change notification is the Edge/Level Triggered Event."
|
||
|
::= { gigamonGigaVUE 3 }
|
||
|
|
||
|
gigamonSnmpConfigSaveNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifFileName }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Config save notification is the Edge/Level Triggered Event."
|
||
|
::= { gigamonGigaVUE 4 }
|
||
|
|
||
|
gigamonSnmpModuleChangeNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifModuleOperationType,
|
||
|
gigamonSnmpNotifModuleName,
|
||
|
gigamonNotifSlotNumber }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"GigaVUE HW module swapping is the triggered Event."
|
||
|
::= { gigamonGigaVUE 5 }
|
||
|
|
||
|
gigamonSnmpPacketDropNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifPortName,
|
||
|
gigamonSnmpNotifCounter }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Packet Drop notification is the Edge/Level Triggered Event."
|
||
|
::= { gigamonGigaVUE 6 }
|
||
|
|
||
|
|
||
|
gigamonSnmpTapRelayChangeNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifPortName,
|
||
|
gigamonSnmpNotifTAPRelayStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"TAP relay change notification is the Edge/Level Triggered Event."
|
||
|
::= { gigamonGigaVUE 7 }
|
||
|
|
||
|
gigamonSnmpPortLinkChangeNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifPortName,
|
||
|
gigamonSnmpNotifPortLinkStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Port link status change notification is the Edge/Level Triggered Event."
|
||
|
::= { gigamonGigaVUE 8 }
|
||
|
|
||
|
gigamonSnmpRxTxErrorNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifPortName,
|
||
|
gigamonSnmpNotifRxTxType,
|
||
|
gigamonSnmpNotifRxTxErrorType,
|
||
|
gigamonSnmpNotifCounter }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Packet receive/transmit error notification is the Edge/Level Triggered Event."
|
||
|
::= { gigamonGigaVUE 9 }
|
||
|
|
||
|
gigamonPowerChangeNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonNotifPowerStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Power supply status change notification is the Edge/Level Triggered Event."
|
||
|
::= { gigamonGigaVUE 10 }
|
||
|
|
||
|
gigamonFanChangeNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifFanName,
|
||
|
gigamonNotifFanStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Fan status change notification is the Edge/Level Triggered Event."
|
||
|
::= { gigamonGigaVUE 11 }
|
||
|
|
||
|
gigamonSnmpOverThresholdChangeNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifPortName,
|
||
|
gigamonSnmpNotifUtilizationAlarm,
|
||
|
gigamonSnmpNotifUtilizationThreshold }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Utilization alarm notification is the Edge/Level Triggered Event."
|
||
|
::= { gigamonGigaVUE 12 }
|
||
|
|
||
|
gigamonSnmpBatteryLevelChangeNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpBatteryLevel }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Battery level down notification."
|
||
|
::= { gigamonGigaVUE 13 }
|
||
|
|
||
|
gigamonLinkSpeedStatusChangeNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifPortName,
|
||
|
gigamonSnmpPortLinkSpeed,
|
||
|
gigamonSnmpPortLinkDuplex,
|
||
|
gigamonSnmpNotifPortLinkStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Link status or speed change notification. "
|
||
|
::= { gigamonGigaVUE 14 }
|
||
|
|
||
|
gigamonPowerSourceChangeNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpPowerSource,
|
||
|
gigamonNotifPowerStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Power source or status change notification."
|
||
|
::= { gigamonGigaVUE 15 }
|
||
|
|
||
|
gigamonSnmpCpuUtilHighNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifCpuIndex,
|
||
|
gigamonSnmpNotifUtilizationThreshold }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The average CPU utilization in the past minute has gone
|
||
|
above the acceptable threshold"
|
||
|
::= { gigamonGigaVUE 16 }
|
||
|
|
||
|
gigamonSnmpUnexpectedShutdownNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The system has shut down unexpectedly"
|
||
|
::= { gigamonGigaVUE 17 }
|
||
|
|
||
|
gigamonSnmpDiskSpaceLowNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifFsMountPoint }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Free space in one of the filesystems is low"
|
||
|
::= { gigamonGigaVUE 18 }
|
||
|
|
||
|
gigamonSnmpWatchdogResetNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription}
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"System reset notification triggered by watchdog timer."
|
||
|
::= { gigamonGigaVUE 19 }
|
||
|
|
||
|
gigamonSnmpBpsFailoverNotification NOTIFICATION-TYPE
|
||
|
OBJECTS { gigamonSnmpNotifHardWareName,
|
||
|
gigamonSnmpNotifLevel,
|
||
|
gigamonSnmpNotifDescription,
|
||
|
gigamonSnmpNotifBpsUnitName,
|
||
|
gigamonSnmpNotifBpsFailoverStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Inline-bypass active unit change notification is the Edge/Level Triggered Event."
|
||
|
::= { gigamonGigaVUE 20 }
|
||
|
|
||
|
END
|