3959 lines
143 KiB
Plaintext
3959 lines
143 KiB
Plaintext
|
-- ****************************************************************************
|
||
|
--
|
||
|
-- System Information
|
||
|
-- Management Information Base for SNMP Network Management
|
||
|
--
|
||
|
--
|
||
|
-- Copyright 1992,2008 Hewlett-Packard Development Company, L.P.
|
||
|
--
|
||
|
-- Hewlett-Packard Company shall not be liable for technical or
|
||
|
-- editorial errors or omissions contained herein. The information in
|
||
|
-- this document is provided "as is" without warranty of any kind and
|
||
|
-- is subject to change without notice. The warranties for HP products
|
||
|
-- are set forth in the express limited warranty statements
|
||
|
-- accompanying such products. Nothing herein should be construed as
|
||
|
-- constituting an additional warranty.
|
||
|
--
|
||
|
-- Confidential computer software. Valid license from HP required for
|
||
|
-- possession, use or copying. Consistent with FAR 12.211 and 12.212,
|
||
|
-- Commercial Computer Software, Computer Software Documentation, and
|
||
|
-- Technical Data for Commercial Items are licensed to the U.S.
|
||
|
-- Government under vendor's standard commercial license.
|
||
|
--
|
||
|
-- Refer to the READMIB.RDM file for more information about the
|
||
|
-- organization of the information in the Compaq Enterprise.
|
||
|
--
|
||
|
-- The Compaq Enterprise number is 232.
|
||
|
-- The ASN.1 prefix to, and including the Compaq Enterprise is:
|
||
|
-- 1.3.6.1.4.1.232
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
CPQSINFO-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
compaq FROM CPQHOST-MIB
|
||
|
DisplayString FROM RFC1213-MIB
|
||
|
OBJECT-TYPE FROM RFC-1212
|
||
|
sysName FROM RFC1213-MIB
|
||
|
cpqHoTrapFlags FROM CPQHOST-MIB
|
||
|
TRAP-TYPE FROM RFC-1215;
|
||
|
|
||
|
|
||
|
-- compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
||
|
cpqSystemInfo OBJECT IDENTIFIER ::= { compaq 2 }
|
||
|
cpqSiMibRev OBJECT IDENTIFIER ::= { cpqSystemInfo 1 }
|
||
|
cpqSiComponent OBJECT IDENTIFIER ::= { cpqSystemInfo 2 }
|
||
|
|
||
|
cpqSiInterface OBJECT IDENTIFIER ::= { cpqSiComponent 1 }
|
||
|
cpqSiAsset OBJECT IDENTIFIER ::= { cpqSiComponent 2 }
|
||
|
cpqSiSecurity OBJECT IDENTIFIER ::= { cpqSiComponent 3 }
|
||
|
cpqSiSystemBoard OBJECT IDENTIFIER ::= { cpqSiComponent 4 }
|
||
|
cpqSiBoardRev OBJECT IDENTIFIER ::= { cpqSiComponent 5 }
|
||
|
cpqSiRackServer OBJECT IDENTIFIER ::= { cpqSiComponent 6 }
|
||
|
cpqSiVideo OBJECT IDENTIFIER ::= { cpqSiComponent 7 }
|
||
|
cpqSiMonitor OBJECT IDENTIFIER ::= { cpqSiComponent 8 }
|
||
|
cpqSiHotPlugSlot OBJECT IDENTIFIER ::= { cpqSiComponent 9 }
|
||
|
cpqSiSystemBattery OBJECT IDENTIFIER ::= { cpqSiComponent 10 }
|
||
|
cpqSiDockingStation OBJECT IDENTIFIER ::= { cpqSiComponent 11 }
|
||
|
cpqSiFru OBJECT IDENTIFIER ::= { cpqSiComponent 12 }
|
||
|
cpqSiRackEnclosure OBJECT IDENTIFIER ::= { cpqSiComponent 13 }
|
||
|
cpqSiServerBlade OBJECT IDENTIFIER ::= { cpqSiComponent 14 }
|
||
|
cpqSiRack OBJECT IDENTIFIER ::= { cpqSiComponent 15 }
|
||
|
cpqSiMP OBJECT IDENTIFIER ::= { cpqSiComponent 16 }
|
||
|
|
||
|
cpqSiOsCommon OBJECT IDENTIFIER ::= { cpqSiInterface 4 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information MIB Revision
|
||
|
-- ===============================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiMibRev Group (1.3.6.1.4.1.232.2.1)
|
||
|
--
|
||
|
-- Implementation of the MibRev group is mandatory for all Insight Agents
|
||
|
-- supporting the System Information MIB.
|
||
|
--
|
||
|
-- An Agent conforming to this document will return a
|
||
|
-- cpqSiMibRevMajor of one (1) and a cpqSiMibRevMinor of thirty-seven (39).
|
||
|
--
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiMibRevMajor OBJECT-TYPE
|
||
|
SYNTAX INTEGER (1..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The major revision level of the MIB.
|
||
|
|
||
|
A change in the major revision level represents a major change
|
||
|
in the architecture of the MIB. A change in the major revision
|
||
|
level may indicate a significant change in the information
|
||
|
supported and/or the meaning of the supported information,
|
||
|
correct interpretation of data may require a MIB document with
|
||
|
the same major revision level."
|
||
|
::= { cpqSiMibRev 1 }
|
||
|
|
||
|
cpqSiMibRevMinor OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The minor revision level of the MIB.
|
||
|
|
||
|
A change in the minor revision level may represent some minor
|
||
|
additional support, no changes to any pre-existing information
|
||
|
has occurred."
|
||
|
::= { cpqSiMibRev 2 }
|
||
|
|
||
|
cpqSiMibCondition OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2), -- default
|
||
|
degraded(3),
|
||
|
failed(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The overall condition.
|
||
|
|
||
|
This object represents the overall status of the server
|
||
|
information represented by this MIB."
|
||
|
::= { cpqSiMibRev 3 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Common
|
||
|
-- =========================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiInterface Group (1.3.6.1.4.1.232.2.2.1)
|
||
|
-- cpqSiOsCommon Group (1.3.6.1.4.1.232.2.2.1.4)
|
||
|
--
|
||
|
--
|
||
|
-- Implementation of the cpqSiOsCommon group is mandatory for all
|
||
|
-- Insight Agents that support the System Information MIB.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiOsCommonPollFreq OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Insight Agent's polling frequency.
|
||
|
|
||
|
The frequency, in seconds, at which the Insight Agent requests
|
||
|
information from the device driver. A frequency of zero (0)
|
||
|
indicates that the Insight Agent retrieves the information upon
|
||
|
request of a management station, it does not poll the device
|
||
|
driver at a specific interval.
|
||
|
|
||
|
If the poll frequency is zero (0) all attempts to write to this
|
||
|
object will fail. If the poll frequency is non-zero,
|
||
|
setting this value will change the polling frequency of the
|
||
|
Insight Agent. Setting the poll frequency to zero (0) will
|
||
|
always fail, an agent may also choose to fail any request to
|
||
|
change the poll frequency to a value that would severely impact
|
||
|
system performance."
|
||
|
::= { cpqSiOsCommon 1 }
|
||
|
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Common Module Table
|
||
|
-- ======================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiInterface Group (1.3.6.1.4.1.232.2.2.1)
|
||
|
-- cpqSiOsCommon Group (1.3.6.1.4.1.232.2.2.1.4)
|
||
|
-- cpqSiOsCommonModuleTable (1.3.6.1.4.1.232.2.2.1.4.2) deprecated
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiOsCommonModuleTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiOsCommonModuleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"A table of software modules that provide an interface to the
|
||
|
device this MIB describes."
|
||
|
::= { cpqSiOsCommon 2 }
|
||
|
|
||
|
cpqSiOsCommonModuleEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiOsCommonModuleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"A description of a software module that provides an interface
|
||
|
to the device this MIB describes."
|
||
|
INDEX { cpqSiOsCommonModuleIndex }
|
||
|
::= { cpqSiOsCommonModuleTable 1 }
|
||
|
|
||
|
CpqSiOsCommonModuleEntry ::= SEQUENCE {
|
||
|
cpqSiOsCommonModuleIndex INTEGER,
|
||
|
cpqSiOsCommonModuleName DisplayString,
|
||
|
cpqSiOsCommonModuleVersion DisplayString,
|
||
|
cpqSiOsCommonModuleDate OCTET STRING,
|
||
|
cpqSiOsCommonModulePurpose DisplayString
|
||
|
}
|
||
|
|
||
|
cpqSiOsCommonModuleIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"A unique index for this module description."
|
||
|
::= { cpqSiOsCommonModuleEntry 1 }
|
||
|
|
||
|
cpqSiOsCommonModuleName OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The module name."
|
||
|
::= { cpqSiOsCommonModuleEntry 2 }
|
||
|
|
||
|
cpqSiOsCommonModuleVersion OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..5))
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The module version in XX.YY format.
|
||
|
|
||
|
Where XX is the major version number and YY is the minor version
|
||
|
number. This field will be a null (size 0) string if the agent
|
||
|
cannot provide the module version."
|
||
|
::= { cpqSiOsCommonModuleEntry 3 }
|
||
|
|
||
|
cpqSiOsCommonModuleDate OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (7))
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The module date.
|
||
|
|
||
|
field octets contents range
|
||
|
===== ====== ======= =====
|
||
|
1 1-2 year 0..65536
|
||
|
2 3 month 1..12
|
||
|
3 4 day 1..31
|
||
|
4 5 hour 0..23
|
||
|
5 6 minute 0..59
|
||
|
6 7 second 0..60
|
||
|
(use 60 for leap-second)
|
||
|
|
||
|
|
||
|
This field will be set to year = 0 if the agent cannot provide
|
||
|
the module date. The hour, minute, and second field will be set
|
||
|
to zero (0) if they are not relevant. The year field is set
|
||
|
with the most significant octet first."
|
||
|
::= { cpqSiOsCommonModuleEntry 4 }
|
||
|
|
||
|
cpqSiOsCommonModulePurpose OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The purpose of the module described in this entry."
|
||
|
::= { cpqSiOsCommonModuleEntry 5 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Asset Group
|
||
|
-- ==============================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiAsset Group (1.3.6.1.4.1.232.2.2.2)
|
||
|
--
|
||
|
-- The cpqSiAsset group contains the serial numbers of any hardware
|
||
|
-- that supports asset management.
|
||
|
--
|
||
|
-- Implementation of the cpqSiAsset group is mandatory for all Insight
|
||
|
-- Agents that support the System Information MIB.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiSysSerialNum OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The serial number of the physical system unit.
|
||
|
|
||
|
The string will be empty if the system does not report the
|
||
|
serial number function."
|
||
|
::= { cpqSiAsset 1 }
|
||
|
|
||
|
cpqSiFormFactor OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown(1),
|
||
|
portable(2),
|
||
|
laptop(3),
|
||
|
desktop(4),
|
||
|
tower(5),
|
||
|
mini-tower(6),
|
||
|
rack-mount(7),
|
||
|
nultiboard-chasis(8)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The form factor of the system. Setting this variable to
|
||
|
unknown will fail."
|
||
|
::= { cpqSiAsset 2 }
|
||
|
|
||
|
cpqSiAssetTag OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The customer changeable identifier that is set to the system
|
||
|
serial number at the time of manufacture.
|
||
|
|
||
|
The string will be empty if the system does not report this
|
||
|
function."
|
||
|
::= { cpqSiAsset 3 }
|
||
|
|
||
|
cpqSiOwnershipTag OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..79))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This is a customer changeable identifier that will be
|
||
|
displayed by ROM at POST. This is an 80 byte standard
|
||
|
ASCII character string and is Administrator Password
|
||
|
protected.
|
||
|
|
||
|
An example could be:
|
||
|
Property of Hewlett-Packard Company
|
||
|
|
||
|
The string should be NULL terminated. This item will be
|
||
|
empty if the system does not report this function."
|
||
|
::= { cpqSiAsset 4 }
|
||
|
|
||
|
cpqSiSysServiceNum OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The service number of the system unit.
|
||
|
|
||
|
The string will be empty if the system does not report the
|
||
|
system service number."
|
||
|
::= { cpqSiAsset 5 }
|
||
|
|
||
|
cpqSiSysProductId OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The product id string of the system unit.
|
||
|
|
||
|
The string will be empty if the system does not report the
|
||
|
product id."
|
||
|
::= { cpqSiAsset 6 }
|
||
|
|
||
|
cpqSiAssetTagMaxLength OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
" Maximum allowed size in bytes of the asset tag."
|
||
|
|
||
|
::= { cpqSiAsset 7 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- Virtual System Information Table
|
||
|
-- ================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiAsset Group (1.3.6.1.4.1.232.2.2.2)
|
||
|
-- cpqSiVirtualSystemTable (1.3.6.1.4.1.232.2.2.2.8)
|
||
|
-- cpqSiVirtualSystemEntry (1.3.6.1.4.1.232.2.2.2.8.1)
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiVirtualSystemTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiVirtualSystemEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A table of virtual system information entries."
|
||
|
::= { cpqSiAsset 8 }
|
||
|
|
||
|
cpqSiVirtualSystemEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiVirtualSystemEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A virtual system information table entry."
|
||
|
INDEX { cpqSiVirtualSystemIndex }
|
||
|
::= { cpqSiVirtualSystemTable 1 }
|
||
|
|
||
|
CpqSiVirtualSystemEntry ::= SEQUENCE {
|
||
|
cpqSiVirtualSystemIndex INTEGER,
|
||
|
cpqSiVirtualSystemSerialNumber DisplayString,
|
||
|
cpqSiVirtualSystemUUID DisplayString
|
||
|
}
|
||
|
|
||
|
cpqSiVirtualSystemIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The unique index of the virtual system information entry."
|
||
|
::= { cpqSiVirtualSystemEntry 1 }
|
||
|
|
||
|
cpqSiVirtualSystemSerialNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The HP Virtual Serial Number for the computer system package. The Virtual
|
||
|
Serial Number is the system serial number exposed to the operating
|
||
|
system when running in an HP Virtual Connect environment. The Virtual
|
||
|
Serial Number presented here will correspond to the Virtual UUID at the
|
||
|
same index location."
|
||
|
::= { cpqSiVirtualSystemEntry 2 }
|
||
|
|
||
|
cpqSiVirtualSystemUUID OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The HP Virtual UUID for the computer system package. The Virtual
|
||
|
UUID is the UUID number exposed to the operating system when running
|
||
|
in an HP Virtual Connect environment. The Virtual UUID presented
|
||
|
here will correspond to the Virtual serial number at the same index
|
||
|
location."
|
||
|
::= { cpqSiVirtualSystemEntry 3 }
|
||
|
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Security Group
|
||
|
-- =================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiSecurity Group (1.3.6.1.4.1.232.2.2.3)
|
||
|
--
|
||
|
-- The Security group describes how the security features on your
|
||
|
-- computer are currently configured.
|
||
|
--
|
||
|
-- Implementation of the security group is mandatory for all agents that
|
||
|
-- support the System Information MIB.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiPowerOnPassword OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the power on password feature."
|
||
|
::= { cpqSiSecurity 1 }
|
||
|
|
||
|
cpqSiNetServerMode OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the network server mode feature."
|
||
|
::= { cpqSiSecurity 2 }
|
||
|
|
||
|
cpqSiQuickLockPassword OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the quicklock password feature."
|
||
|
::= { cpqSiSecurity 3 }
|
||
|
|
||
|
cpqSiQuickBlank OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the quick blank screen feature."
|
||
|
::= { cpqSiSecurity 4 }
|
||
|
|
||
|
cpqSiDisketteBootControl OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the diskette boot control feature."
|
||
|
::= { cpqSiSecurity 5 }
|
||
|
|
||
|
cpqSiSerialPortAControl OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the access control for the primary serial port
|
||
|
interface embedded in the system board."
|
||
|
::= { cpqSiSecurity 6 }
|
||
|
|
||
|
cpqSiSerialPortBControl OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the access control for the secondary serial port
|
||
|
interface embedded in the system board."
|
||
|
::= { cpqSiSecurity 7 }
|
||
|
|
||
|
cpqSiParallelPortControl OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the access control for the parallel port interface
|
||
|
embedded in the system board."
|
||
|
::= { cpqSiSecurity 8 }
|
||
|
|
||
|
cpqSiFloppyDiskControl OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the access control for the floppy diskette
|
||
|
interface embedded in the system board."
|
||
|
::= { cpqSiSecurity 9 }
|
||
|
|
||
|
cpqSiFixedDiskControl OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the access control for the fixed disk interface
|
||
|
embedded in the system board."
|
||
|
::= { cpqSiSecurity 10 }
|
||
|
|
||
|
cpqSiHoodRemovedTime OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Last detection of hood removed by Smart Hood Sensor."
|
||
|
|
||
|
::= { cpqSiSecurity 11 }
|
||
|
|
||
|
cpqSiHoodSensorConfiguration OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
notifyUser(3),
|
||
|
adminPasswordProtected(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This is the current configuration of the Smart Cover
|
||
|
sensor.
|
||
|
|
||
|
The following values are currently defined:
|
||
|
|
||
|
other(1)
|
||
|
Smart Cover sensor is not supported on this system or cannot
|
||
|
be determined by the Insight Agent. You may need to upgrade
|
||
|
your software.
|
||
|
|
||
|
disabled(2)
|
||
|
Smart Cover sensor will not detect a hood removal and
|
||
|
cpqSiHoodRemovedTime will not be updated.
|
||
|
|
||
|
notifyUser(3)
|
||
|
Smart Cover sensor will detect a hood removal and will display
|
||
|
a message at POST for the user.
|
||
|
|
||
|
adminPasswordProtected(4)
|
||
|
Smart Cover sensor will detect a hood removal and will display
|
||
|
a message at POST for the user to enter the Admin Password.
|
||
|
The system will not boot until proper password is entered."
|
||
|
::= { cpqSiSecurity 12 }
|
||
|
|
||
|
|
||
|
cpqSiSmartCoverLockStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
unlocked(2),
|
||
|
locked(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This is the current status of the Smart Cover
|
||
|
Lock. The following values are currently defined:
|
||
|
|
||
|
other(1)
|
||
|
Smart Cover Lock is not supported on this system or cannot
|
||
|
be determined by the Insight Agent. You may need to upgrade
|
||
|
your software.
|
||
|
|
||
|
unlocked(2)
|
||
|
Smart Cover Lock is not locked. The status will be set to
|
||
|
unlocked due to one of the following:
|
||
|
1. The system hood is removed, or
|
||
|
2. There is no administrator password set, or
|
||
|
3. The administrator manually sets status to unlock.
|
||
|
|
||
|
locked(3)
|
||
|
Smart Cover Lock is locked. The administrator password is
|
||
|
required to unlock the hood."
|
||
|
::= { cpqSiSecurity 13 }
|
||
|
|
||
|
cpqSiUSBPortControl OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3),
|
||
|
legacydisabled(4),
|
||
|
externalportdisabled(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the access control for the Universal
|
||
|
Serial Bus interface(s) embedded in the system
|
||
|
board.
|
||
|
|
||
|
other(1)
|
||
|
If Status could not be determined.
|
||
|
|
||
|
disabled(2)
|
||
|
USB interface is disable.
|
||
|
|
||
|
enabled(3)
|
||
|
USB interface is enable.
|
||
|
|
||
|
legacydisabled(4)
|
||
|
Legacy USB interface is disabled.
|
||
|
|
||
|
externalportdisabled(5)
|
||
|
External USB Ports are disabled."
|
||
|
::= { cpqSiSecurity 14 }
|
||
|
|
||
|
cpqSiVirtualSerialPortControl OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the access control for the virtual serial port interface
|
||
|
embedded in the system board."
|
||
|
::= { cpqSiSecurity 15 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information System Board Group
|
||
|
-- =====================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4)
|
||
|
--
|
||
|
-- The cpqSiSystemBoard group describe features of your computer
|
||
|
-- system board.
|
||
|
--
|
||
|
-- Implementation of the cpqSiSystemBoard group is mandatory for all agents
|
||
|
-- that support the System Information MIB.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiProductId OBJECT-TYPE
|
||
|
SYNTAX INTEGER (1..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The machine product ID.
|
||
|
|
||
|
This value indicates the product type of the system board
|
||
|
in this system. The value 127 will be given if the machine ID
|
||
|
cannot be determined. A value of 127 will also be used for the
|
||
|
special case of a machine containing neither EISA nor ISA slots."
|
||
|
::= { cpqSiSystemBoard 1 }
|
||
|
|
||
|
cpqSiProductName OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The machine product name.
|
||
|
|
||
|
The name of the machine used in this system."
|
||
|
::= { cpqSiSystemBoard 2 }
|
||
|
|
||
|
cpqSiAuxiliaryInput OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of the auxiliary input (pointing) device."
|
||
|
::= { cpqSiSystemBoard 4 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Memory Module Table
|
||
|
-- ======================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4)
|
||
|
-- cpqSiMemModuleTable (1.3.6.1.4.1.232.2.2.4.5)
|
||
|
-- cpqSiMemModuleEntry (1.3.6.1.4.1.232.2.2.4.5.1)
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
-- Deprecated this table in 8.20 time frame please use the
|
||
|
-- cpqHeResMem2ModuleTable tables to get value
|
||
|
|
||
|
cpqSiMemModuleTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiMemModuleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A table of memory module descriptions."
|
||
|
::= { cpqSiSystemBoard 5 }
|
||
|
|
||
|
cpqSiMemModuleEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiMemModuleEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A memory module description."
|
||
|
INDEX { cpqSiMemBoardIndex , cpqSiMemModuleIndex }
|
||
|
::= { cpqSiMemModuleTable 1 }
|
||
|
|
||
|
CpqSiMemModuleEntry ::= SEQUENCE {
|
||
|
cpqSiMemBoardIndex INTEGER,
|
||
|
cpqSiMemModuleIndex INTEGER,
|
||
|
cpqSiMemModuleSize INTEGER,
|
||
|
cpqSiMemModuleType INTEGER,
|
||
|
cpqSiMemModuleSpeed INTEGER, -- deprecated
|
||
|
cpqSiMemModuleTechnology INTEGER,
|
||
|
cpqSiMemModuleManufacturer DisplayString,
|
||
|
cpqSiMemModulePartNo DisplayString,
|
||
|
cpqSiMemModuleDate OCTET STRING,
|
||
|
cpqSiMemModuleSerialNo DisplayString,
|
||
|
cpqSiMemModuleECCStatus INTEGER,
|
||
|
cpqSiMemModuleHwLocation DisplayString,
|
||
|
cpqSiMemModuleFrequency INTEGER,
|
||
|
cpqSiMemModuleCellTablePtr INTEGER,
|
||
|
cpqSiMemModuleCellStatus INTEGER,
|
||
|
cpqSiMemModulePartNoMfgr DisplayString,
|
||
|
cpqSiMemModuleSerialNoMfgr DisplayString
|
||
|
}
|
||
|
|
||
|
cpqSiMemBoardIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The slot in which the memory board or cartridge is installed.
|
||
|
|
||
|
A value of 0 indicates memory installed directly on the
|
||
|
system board."
|
||
|
::= { cpqSiMemModuleEntry 1 }
|
||
|
|
||
|
cpqSiMemModuleIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The memory module number."
|
||
|
::= { cpqSiMemModuleEntry 2 }
|
||
|
|
||
|
cpqSiMemModuleSize OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Module memory size in kilobytes. A kilobyte of memory is
|
||
|
defined as 1024 bytes.
|
||
|
|
||
|
A size of 0 indicates the module is not present."
|
||
|
::= { cpqSiMemModuleEntry 3 }
|
||
|
|
||
|
cpqSiMemModuleType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
board(2),
|
||
|
cpqSingleWidthModule(3),
|
||
|
cpqDoubleWidthModule(4),
|
||
|
simm(5),
|
||
|
pcmcia(6),
|
||
|
compaq-specific(7),
|
||
|
dimm(8),
|
||
|
smallOutlineDimm(9),
|
||
|
rimm(10),
|
||
|
srimm(11),
|
||
|
fb-dimm(12)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Type of memory module installed. The value other(1) will be
|
||
|
given if the type is not known. The value board(2) will be
|
||
|
given if the memory module is permanently mounted (not modular)
|
||
|
on a system board or memory expansion board."
|
||
|
::= { cpqSiMemModuleEntry 4 }
|
||
|
|
||
|
cpqSiMemModuleSpeed OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"Module memory speed in nanoseconds. The value zero (0) will
|
||
|
be given if the module speed cannot be determined."
|
||
|
::= { cpqSiMemModuleEntry 5 }
|
||
|
|
||
|
cpqSiMemModuleTechnology OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
fastPageMode(2),
|
||
|
edoPageMode(3),
|
||
|
burstEdoPageMode(4),
|
||
|
synchronous(5),
|
||
|
rdram(6)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Technology type of memory module installed. The value other(1)
|
||
|
will be given if the technology is not known."
|
||
|
::= { cpqSiMemModuleEntry 6 }
|
||
|
|
||
|
cpqSiMemModuleManufacturer OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The memory module's manufacturer name.
|
||
|
|
||
|
This field will be a null (size 0) string if the manufacturer
|
||
|
name is not available."
|
||
|
::= { cpqSiMemModuleEntry 7 }
|
||
|
|
||
|
cpqSiMemModulePartNo OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The memory module's manufacturer part number.
|
||
|
|
||
|
This field will be a null (size 0) string if the manufacturer
|
||
|
part number is not available."
|
||
|
::= { cpqSiMemModuleEntry 8 }
|
||
|
|
||
|
cpqSiMemModuleDate OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (7))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The memory module date of manufacture.
|
||
|
|
||
|
field octets contents range
|
||
|
===== ====== ====================== ========
|
||
|
1 1-2 year 0..65536
|
||
|
2 3 month 1..12
|
||
|
3 4 day 1..31
|
||
|
4 5 hour 0..23
|
||
|
5 6 minute 0..59
|
||
|
6 7 second 0..60
|
||
|
(use 60 for leap-second)
|
||
|
|
||
|
This field will be set to year = 0 if the date of manufacture
|
||
|
is not available. The hour, minute, and second fields will
|
||
|
always be set to 0."
|
||
|
::= { cpqSiMemModuleEntry 9 }
|
||
|
|
||
|
cpqSiMemModuleSerialNo OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The memory module's serial number.
|
||
|
|
||
|
This field will be a null (size 0) string if the serial number
|
||
|
is not available."
|
||
|
::= { cpqSiMemModuleEntry 10 }
|
||
|
|
||
|
cpqSiMemModuleECCStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
degraded(3),
|
||
|
degradedModuleIndexUnknown(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This provides the current status of the correctable memory
|
||
|
errors for this memory module.
|
||
|
|
||
|
The following status values are supported:
|
||
|
|
||
|
other(1):
|
||
|
ECC is not supported on this memory module.
|
||
|
|
||
|
ok(2):
|
||
|
The correctable error count is below threshold.
|
||
|
|
||
|
degraded(3):
|
||
|
The correctable error count has exceeded threshold.
|
||
|
|
||
|
degradedModuleIndexUnknown(4):
|
||
|
The correctable error count has exceeded threshold.
|
||
|
The module index not available."
|
||
|
::= { cpqSiMemModuleEntry 11 }
|
||
|
|
||
|
cpqSiMemModuleHwLocation OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A text description of the hardware location, on complex
|
||
|
multi SBB hardware only, for the memory module.
|
||
|
A NULL string indicates that the hardware location could not
|
||
|
be determined or is irrelevant."
|
||
|
::= { cpqSiMemModuleEntry 12 }
|
||
|
|
||
|
|
||
|
cpqSiMemModuleFrequency OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The memory module frequency in MHz. The value zero (0) will
|
||
|
be given if the module frequency cannot be determined."
|
||
|
::= { cpqSiMemModuleEntry 13 }
|
||
|
|
||
|
cpqSiMemModuleCellTablePtr OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..15)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Index for the cell in cpqSeCellTable where the memory board is
|
||
|
installed."
|
||
|
::= { cpqSiMemModuleEntry 14 }
|
||
|
|
||
|
cpqSiMemModuleCellStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
deconfigured(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This provides the current status for this memory module.
|
||
|
|
||
|
The following status values are supported:
|
||
|
|
||
|
other(1):
|
||
|
The memory module status is not available
|
||
|
|
||
|
ok(2):
|
||
|
The memory module is active
|
||
|
|
||
|
deconfigured(3):
|
||
|
The memory module is not ready"
|
||
|
::= { cpqSiMemModuleEntry 15 }
|
||
|
|
||
|
|
||
|
cpqSiMemModulePartNoMfgr OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The memory module's manufacturer's part number.
|
||
|
|
||
|
This field will be a null (size 0) string if the manufacturer
|
||
|
part number is not available."
|
||
|
::= { cpqSiMemModuleEntry 16 }
|
||
|
|
||
|
cpqSiMemModuleSerialNoMfgr OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The memory module's manufacturer's serial number.
|
||
|
|
||
|
This field will be a null (size 0) string if the manufacturer
|
||
|
serial number is not available."
|
||
|
::= { cpqSiMemModuleEntry 17 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information System Board Group
|
||
|
-- =====================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4)
|
||
|
--
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiSystemId OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The System ID.
|
||
|
|
||
|
This value indicates the system ID of the system board
|
||
|
in this system. This ID replaces the product ID used in
|
||
|
older machines (cpqSiProductId). A value of 7Eh for the
|
||
|
cpqSiProductId indicates that the cpqSiSystemId should be
|
||
|
used to identify the system. A value of zero (0)
|
||
|
indicates that the system ID function is not supported on this
|
||
|
machine. In this case, the cpqSiProductId should be used to
|
||
|
identify the system."
|
||
|
::= { cpqSiSystemBoard 6 }
|
||
|
|
||
|
cpqSiSystemCpuId OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The System ID : CPU Component.
|
||
|
|
||
|
This value indicates the CPU type of the system board
|
||
|
in this system. A value of zero (0) indicates that the CPU
|
||
|
type cannot be determined."
|
||
|
::= { cpqSiSystemBoard 7 }
|
||
|
|
||
|
cpqSiFlashRomSupport OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
notSupported(2),
|
||
|
supported(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value indicates if this system supports flash upgradable
|
||
|
system ROM."
|
||
|
::= { cpqSiSystemBoard 8 }
|
||
|
|
||
|
cpqSiQuickTestRomDate OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (7))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value indicates the date of the current quick test ROM
|
||
|
image.
|
||
|
|
||
|
field octets contents range
|
||
|
===== ====== ======= =====
|
||
|
1 1-2 year 0..65536
|
||
|
2 3 month 1..12
|
||
|
3 4 day 1..31
|
||
|
4 5 hour 0..23
|
||
|
5 6 minute 0..59
|
||
|
6 7 second 0..60
|
||
|
(use 60 for leap-second)
|
||
|
|
||
|
|
||
|
This field will be set to year = 0 if quick test ROM is not
|
||
|
present. The hour, minute, and second field will be set
|
||
|
to zero (0) if they are not relevant. The year field is set
|
||
|
with the most significant octet first."
|
||
|
::= { cpqSiSystemBoard 9 }
|
||
|
|
||
|
cpqSiReboot OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
notAvailable(1),
|
||
|
available(2),
|
||
|
defaultOnlyAvailable(3),
|
||
|
rebootToCpqUtils(2693),
|
||
|
rebootToDefault(8115),
|
||
|
autoShutdown(9037)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"This object may contain the following values:
|
||
|
notAvailable(1)
|
||
|
the system does not support the reboot functionality.
|
||
|
Setting this object to notAvailable(1) has no effect.
|
||
|
|
||
|
available(2)
|
||
|
the system supports the both reboot to functionalities.
|
||
|
Setting this object to available(2) has no effect.
|
||
|
|
||
|
defaultOnlyAvailable(3)
|
||
|
the system supports the only the default reboot functionality.
|
||
|
Setting this object to available(3) has no effect.
|
||
|
|
||
|
rebootToCpqUtils(2693)
|
||
|
the system will reboot to the System Utilities if
|
||
|
the reboot functionality is available. If possible,
|
||
|
the agent will attempt to gracefully shutdown the
|
||
|
operating system before performing the reboot.
|
||
|
If this functionality is unavailable on this system
|
||
|
then all sets will have no effect.
|
||
|
|
||
|
rebootToDefault(8115)
|
||
|
the system will reboot and allow the default boot
|
||
|
process to occur if the reboot functionality is
|
||
|
available. If possible, the agent will attempt to
|
||
|
gracefully shutdown the operating system before
|
||
|
performing the reboot. If this functionality is
|
||
|
unavailable on this system then all sets will have
|
||
|
no effect.
|
||
|
|
||
|
autoShutdown(9037)
|
||
|
If possible, the agent will attempt to gracefully
|
||
|
shutdown the operating system. The agent will not
|
||
|
preform a reboot.
|
||
|
|
||
|
"
|
||
|
|
||
|
::= { cpqSiSystemBoard 10 }
|
||
|
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Processor Microcode Patch Table
|
||
|
-- ==================================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4)
|
||
|
-- cpqSiProcMicroPatchTable (1.3.6.1.4.1.232.2.2.4.11)
|
||
|
-- cpqSiProcMicroPatchEntry (1.3.6.1.4.1.232.2.2.4.11.1)
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiProcMicroPatchTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiProcMicroPatchEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This table lists the set of processor microcode patches that
|
||
|
the system ROM contains. During post, the ROM will apply the
|
||
|
appropriate patches to the CPU microcode. Scan this table to
|
||
|
ensure that a patch is being applied to a processor."
|
||
|
::= { cpqSiSystemBoard 11 }
|
||
|
|
||
|
cpqSiProcMicroPatchEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiProcMicroPatchEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"An entry describing one microcode patch contained in the system
|
||
|
ROM."
|
||
|
INDEX { cpqSiProcMicroPatchIndex }
|
||
|
::= { cpqSiProcMicroPatchTable 1 }
|
||
|
|
||
|
CpqSiProcMicroPatchEntry ::= SEQUENCE {
|
||
|
cpqSiProcMicroPatchIndex INTEGER,
|
||
|
cpqSiProcMicroPatchId INTEGER,
|
||
|
cpqSiProcMicroPatchDate OCTET STRING,
|
||
|
cpqSiProcMicroPatchFamily OCTET STRING }
|
||
|
|
||
|
cpqSiProcMicroPatchIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (1..255)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Index into the microcode patch table."
|
||
|
::= { cpqSiProcMicroPatchEntry 1 }
|
||
|
|
||
|
cpqSiProcMicroPatchId OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The ID of this particular CPU microcode patch."
|
||
|
::= { cpqSiProcMicroPatchEntry 2 }
|
||
|
|
||
|
cpqSiProcMicroPatchDate OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (7))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value indicates the date of this CPU microcode patch.
|
||
|
|
||
|
field octets contents range
|
||
|
===== ====== ======= =====
|
||
|
1 1-2 year 0..65536
|
||
|
2 3 month 1..12
|
||
|
3 4 day 1..31
|
||
|
4 5 hour 0..23
|
||
|
5 6 minute 0..59
|
||
|
6 7 second 0..60
|
||
|
(use 60 for leap-second)
|
||
|
|
||
|
NOTE: Year is stored in packed BCD. The most significant
|
||
|
part is in the second octet. For example:
|
||
|
1995 would be stored as 0x95 0x19.
|
||
|
|
||
|
The hour, minute, and second field will be set to zero (0)
|
||
|
if they are not relevant. The year field is set with the
|
||
|
most significant octet first."
|
||
|
::= { cpqSiProcMicroPatchEntry 3 }
|
||
|
|
||
|
cpqSiProcMicroPatchFamily OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (3))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The valid family/model/step of the processor that this CPU
|
||
|
microcode patch applies to.
|
||
|
|
||
|
field octets contents range
|
||
|
===== ====== ======= =====
|
||
|
1 1 CPU Step 0..255
|
||
|
2 2 CPU Model 0..255
|
||
|
3 3 CPU Family 0..255 "
|
||
|
::= { cpqSiProcMicroPatchEntry 4 }
|
||
|
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information System Board Group
|
||
|
-- =====================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4)
|
||
|
--
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiPowerMgmtStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
disabled(2),
|
||
|
enabled(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The state of power management."
|
||
|
::= { cpqSiSystemBoard 12 }
|
||
|
|
||
|
|
||
|
cpqSiRebootFlags OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Reboot Flags.
|
||
|
|
||
|
This is a collection of flags used to indicate the re-boot
|
||
|
options available. This integer is a bitmap, with each bit
|
||
|
indicating the availability of an option. If the bit is set
|
||
|
to 1, the option is available; otherwise it is not. Multiple
|
||
|
options are allowed.
|
||
|
|
||
|
NOTE: bit 31 is the most significant bit, bit 0 is the least
|
||
|
significant.
|
||
|
|
||
|
|
||
|
Status This is a collection of flags. Each bit has the
|
||
|
following meaning when it is on (1):
|
||
|
|
||
|
Bit 31: Execute Set
|
||
|
Bit 30-6: RESERVED
|
||
|
Bit 5: Boot to ROM Based Setup
|
||
|
Bit 4: RESERVED
|
||
|
Bit 3: Boot to OS
|
||
|
Bit 2: Boot to Utils
|
||
|
Bit 1: Warm Boot
|
||
|
Bit 0: Cold Boot"
|
||
|
|
||
|
|
||
|
|
||
|
::= { cpqSiSystemBoard 13 }
|
||
|
|
||
|
cpqSiMemErrorIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Placeholder for memory module number for ECC traps.
|
||
|
Represents the number of the memory module for which an ECC status
|
||
|
change has occurred. Set to 65535 if module number not available."
|
||
|
::= { cpqSiSystemBoard 14 }
|
||
|
|
||
|
cpqSiMemECCCondition OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
degraded(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This provides the current condition of the correctable memory
|
||
|
errors for the entire memory.
|
||
|
|
||
|
The following status values are supported:
|
||
|
|
||
|
other(1) :
|
||
|
ECC is not supported.
|
||
|
|
||
|
ok(2) :
|
||
|
The correctable error count is below threshold.
|
||
|
|
||
|
degraded(3) :
|
||
|
The correctable error count has exceeded threshold."
|
||
|
|
||
|
::= { cpqSiSystemBoard 15 }
|
||
|
|
||
|
cpqSiMemConfigChangeData OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..383))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Text string for the memory configuration change trap."
|
||
|
::= { cpqSiSystemBoard 16 }
|
||
|
|
||
|
cpqSiServerSystemId OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..8))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A Server System ID.
|
||
|
|
||
|
This value is used to uniquely identify systems via a unique
|
||
|
ID on systems that do not support the EISA bus."
|
||
|
::= { cpqSiSystemBoard 17 }
|
||
|
|
||
|
cpqSiPowerScheme OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unsupported(1),
|
||
|
other(2),
|
||
|
power-saver(3),
|
||
|
balanced(4),
|
||
|
high-performance(5),
|
||
|
user-defined(6)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The current active power plan or power scheme of the system."
|
||
|
::= { cpqSiSystemBoard 18 }
|
||
|
|
||
|
cpqSiPowerSchemeName OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The name of current active power plan or power scheme of the
|
||
|
system. When cpqSiPowerScheme has a value of user-defined(6), the
|
||
|
user defined name can be populated here."
|
||
|
::= { cpqSiSystemBoard 19 }
|
||
|
|
||
|
cpqSiCurrentPerformanceStatePointer OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Pointer to cpqSiPerfStateIndex in cpqSiPerfStateTable to indicate the current performance state of the system."
|
||
|
::= { cpqSiSystemBoard 20 }
|
||
|
|
||
|
cpqSiMinPerformanceState OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The slowest performance state by the selected power state policy."
|
||
|
::= { cpqSiSystemBoard 21 }
|
||
|
|
||
|
cpqSiMaxPerformanceState OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The fastest performance state supported by the selected power state policy."
|
||
|
::= { cpqSiSystemBoard 22 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- Performance State Table
|
||
|
-- ================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4)
|
||
|
-- cpqSiPerfStateTable (1.3.6.1.4.1.232.2.2.4.23)
|
||
|
-- cpqSiPerfStateEntry (1.3.6.1.4.1.232.2.2.4.23.1)
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiPerfStateTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiPerfStateEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A table of supported performance states of the system."
|
||
|
::= { cpqSiSystemBoard 23 }
|
||
|
|
||
|
cpqSiPerfStateEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiPerfStateEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"An entry describing a supported performance state of the system."
|
||
|
INDEX { cpqSiPerfStateIndex }
|
||
|
::= { cpqSiPerfStateTable 1 }
|
||
|
|
||
|
CpqSiPerfStateEntry ::= SEQUENCE {
|
||
|
cpqSiPerfStateIndex INTEGER,
|
||
|
cpqSiPerfState INTEGER,
|
||
|
cpqSiPerfStateCpuFrequency INTEGER,
|
||
|
cpqSiPerfStateCpuPower INTEGER
|
||
|
}
|
||
|
|
||
|
cpqSiPerfStateIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Index into the performance state table. cpqSiCurrentPerformanceStatePointer should point to one of these values."
|
||
|
::= { cpqSiPerfStateEntry 1 }
|
||
|
|
||
|
cpqSiPerfState OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0.. 65535)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Performance state number. A unique number assigned to a performance state instance."
|
||
|
::= { cpqSiPerfStateEntry 2 }
|
||
|
|
||
|
cpqSiPerfStateCpuFrequency OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The processor frequency in megahertz for this performance state instance."
|
||
|
::= { cpqSiPerfStateEntry 3 }
|
||
|
|
||
|
cpqSiPerfStateCpuPower OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..2147483647)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The processor power setting in milliwatts for this performance state instance."
|
||
|
::= { cpqSiPerfStateEntry 4 }
|
||
|
|
||
|
cpqSiTPMmodule OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
absent(2),
|
||
|
presentEnabled (3),
|
||
|
presentDisabled (4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This field will be populated if TPM module is present in the system board.
|
||
|
other(1)
|
||
|
No record of TPM exist.
|
||
|
absent(2)
|
||
|
TPM module is not present in the system.
|
||
|
presentEnabled(3)
|
||
|
TPM module is present in the system and currently enabled.
|
||
|
presentDisabled(4)
|
||
|
TPM module is present in the system and currently not enabled."
|
||
|
::= { cpqSiSystemBoard 24 }
|
||
|
|
||
|
cpqSiTrustedModuleType OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Bits[3:0] = Trusted Module Type:
|
||
|
1h = Not Specified
|
||
|
2h = TPM 1.2
|
||
|
3h = TPM 2.0
|
||
|
4h = TM 1.0
|
||
|
5h - 0Fh = Reserved."
|
||
|
|
||
|
::= { cpqSiSystemBoard 25 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Board Revision Group
|
||
|
-- =======================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiBoardRev Group (1.3.6.1.4.1.232.2.2.5)
|
||
|
--
|
||
|
-- The cpqSiBoardRev group describes the board revision information.
|
||
|
--
|
||
|
-- Implementation of the cpqSiBoardRev group is mandatory for all
|
||
|
-- agents that support the System Information MIB in a system that
|
||
|
-- supports the board revision feature.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiCurRevDate OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (8))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current board revision configuration date in MM/DD/YY
|
||
|
format. This is the date that the EISA Configuration Utility
|
||
|
was used to define the current configuration. This value will
|
||
|
contain 'N/A' if this system does not support this feature."
|
||
|
::= { cpqSiBoardRev 1 }
|
||
|
|
||
|
cpqSiPrevRevDate OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (8))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The previous board revision configuration date in MM/DD/YY
|
||
|
format. This is the date that the EISA Configuration Utility
|
||
|
was used to define the previous configuration. This value will
|
||
|
contain 'N/A' if this system does not support this feature."
|
||
|
::= { cpqSiBoardRev 2 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Board Revision Table
|
||
|
-- ========================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiBoardRev Group (1.3.6.1.4.1.232.2.2.5)
|
||
|
-- cpqSiBoardRevTable (1.3.6.1.4.1.232.2.2.5.3)
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiBoardRevTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiBoardRevEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A table of board revision descriptions."
|
||
|
::= { cpqSiBoardRev 3 }
|
||
|
|
||
|
cpqSiBoardRevEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiBoardRevEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A board revision description."
|
||
|
INDEX { cpqSiBoardRevSlotIndex, cpqSiBoardRevIndex }
|
||
|
::= { cpqSiBoardRevTable 1 }
|
||
|
|
||
|
CpqSiBoardRevEntry ::= SEQUENCE {
|
||
|
cpqSiBoardRevSlotIndex INTEGER,
|
||
|
cpqSiBoardRevIndex INTEGER,
|
||
|
cpqSiBoardRevId DisplayString,
|
||
|
cpqSiBoardRevCur DisplayString,
|
||
|
cpqSiBoardRevPrev DisplayString,
|
||
|
cpqSiBoardRevHwLocation DisplayString
|
||
|
}
|
||
|
|
||
|
cpqSiBoardRevSlotIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The slot in which the board described in this entry resides.
|
||
|
Zero (0) indicates the system board."
|
||
|
::= { cpqSiBoardRevEntry 1 }
|
||
|
|
||
|
cpqSiBoardRevIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A number that uniquely specifies which board in a specific slot
|
||
|
is described in this entry. Zero (0) indicates the main board
|
||
|
in this slot. Any other number indicates a daughter board or a
|
||
|
component of the main board."
|
||
|
::= { cpqSiBoardRevEntry 2 }
|
||
|
|
||
|
cpqSiBoardRevId OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..16))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A description of the board type. The defined types are:
|
||
|
|
||
|
Type
|
||
|
==============
|
||
|
System Board
|
||
|
Processor n (n = the processor number)
|
||
|
Memory n (n = the memory board number)
|
||
|
Slot n (n = the slot the board occupies)
|
||
|
|
||
|
Other types may be defined at a later date."
|
||
|
::= { cpqSiBoardRevEntry 3 }
|
||
|
|
||
|
cpqSiBoardRevCur OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..8))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current revision for the board described in this entry.
|
||
|
This value will be N/A if there is no current revision
|
||
|
information."
|
||
|
::= { cpqSiBoardRevEntry 4 }
|
||
|
|
||
|
cpqSiBoardRevPrev OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..8))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The revision for the board described in this entry prior to the
|
||
|
current configuration. This value will be N/A if there is no
|
||
|
previous revision information."
|
||
|
::= { cpqSiBoardRevEntry 5 }
|
||
|
|
||
|
cpqSiBoardRevHwLocation OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A text description of the hardware location, on complex
|
||
|
multi SBB hardware only, for the board.
|
||
|
A NULL string indicates that the hardware location could not
|
||
|
be determined or is irrelevant."
|
||
|
::= { cpqSiBoardRevEntry 6 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Firmware Revision Table
|
||
|
-- ==========================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiBoardRev Group (1.3.6.1.4.1.232.2.2.5)
|
||
|
-- cpqSiFirmwareRevTable (1.3.6.1.4.1.232.2.2.5.4)
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiFirmwareRevTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiFirmwareRevEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A table of firmware revision descriptions."
|
||
|
::= { cpqSiBoardRev 4 }
|
||
|
|
||
|
cpqSiFirmwareRevEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiFirmwareRevEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A firmware revision description."
|
||
|
INDEX { cpqSiFirmwareRevIndex }
|
||
|
::= { cpqSiFirmwareRevTable 1 }
|
||
|
|
||
|
CpqSiFirmwareRevEntry ::= SEQUENCE {
|
||
|
cpqSiFirmwareRevIndex INTEGER,
|
||
|
cpqSiFirmwareRevDesc DisplayString,
|
||
|
cpqSiFirmwareRevString DisplayString,
|
||
|
cpqSiFirmwareRevCellTablePtr INTEGER,
|
||
|
cpqSiFirmwareLocation DisplayString,
|
||
|
cpqSiFirmwareStatus INTEGER
|
||
|
}
|
||
|
|
||
|
cpqSiFirmwareRevIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Locally-unique index for this entry."
|
||
|
::= { cpqSiFirmwareRevEntry 1 }
|
||
|
|
||
|
cpqSiFirmwareRevDesc OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Description, e.g. SRM console, ARC console, System BIOS, etc."
|
||
|
::= { cpqSiFirmwareRevEntry 2 }
|
||
|
|
||
|
cpqSiFirmwareRevString OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Version number, possibly of the form Vx.y or Vx.y-z."
|
||
|
::= { cpqSiFirmwareRevEntry 3 }
|
||
|
|
||
|
cpqSiFirmwareRevCellTablePtr OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"Index for the cell in cpqSeCellTable where this firmware is located"
|
||
|
::= { cpqSiFirmwareRevEntry 4 }
|
||
|
|
||
|
cpqSiFirmwareLocation OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Description of which board the firmware is located in."
|
||
|
::= { cpqSiFirmwareRevEntry 5 }
|
||
|
|
||
|
cpqSiFirmwareStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown(1),
|
||
|
active(2),
|
||
|
inactive(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The current status for this firmware."
|
||
|
::= { cpqSiFirmwareRevEntry 6 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Firmware Configuration Table
|
||
|
-- ===============================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiBoardRev Group (1.3.6.1.4.1.232.2.2.5)
|
||
|
-- cpqSiFirmwareCfgTable (1.3.6.1.4.1.232.2.2.5.5)
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiFirmwareCfgTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiFirmwareCfgEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Table of soft switches and symbols maintained by the
|
||
|
firmware. May be operating system and/or option-specific
|
||
|
and will certainly be system-specific. This list is
|
||
|
intended to be easily extensible and support arbitrary
|
||
|
datatypes. It includes such switches as powerup options,
|
||
|
default dump device, etc.
|
||
|
Note - the string comparison for svrFwSymbolName is case
|
||
|
insensitive."
|
||
|
::= { cpqSiBoardRev 5 }
|
||
|
|
||
|
cpqSiFirmwareCfgEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiFirmwareCfgEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Each entry represents one variable or symbol maintained by
|
||
|
or stored by some instance of firmware in the system."
|
||
|
INDEX { cpqSiFirmwareCfgName }
|
||
|
::= { cpqSiFirmwareCfgTable 1 }
|
||
|
|
||
|
CpqSiFirmwareCfgEntry ::= SEQUENCE {
|
||
|
cpqSiFirmwareCfgName DisplayString,
|
||
|
cpqSiFirmwareCfgValue DisplayString
|
||
|
}
|
||
|
|
||
|
cpqSiFirmwareCfgName OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The firmware configuration symbol name as visible from the
|
||
|
console."
|
||
|
::= { cpqSiFirmwareCfgEntry 1 }
|
||
|
|
||
|
cpqSiFirmwareCfgValue OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The firmware configuration symbol value. Null if none
|
||
|
or unknown."
|
||
|
::= { cpqSiFirmwareCfgEntry 2 }
|
||
|
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Ups Shutdown Group
|
||
|
-- =====================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiRackServer Group (1.3.6.1.4.1.232.2.2.6)
|
||
|
--
|
||
|
-- The cpqSiRackServer group describes this system's role in a rack
|
||
|
-- family.
|
||
|
--
|
||
|
-- Implementation of the cpqSiRackServer group is mandatory for all
|
||
|
-- agents that support the System Information MIB in a system that
|
||
|
-- supports Rack Server features.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiRackServerShutdownRole OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
master(2),
|
||
|
slave(3)
|
||
|
}
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This entry describes this system's role in a rack-mounted
|
||
|
uninterruptible power supply family. The master both
|
||
|
communicates with the UPS and derives its power from the
|
||
|
UPS. The slave derives its power from the UPS, but does
|
||
|
not communicate with it."
|
||
|
::= { cpqSiRackServer 1 }
|
||
|
|
||
|
cpqSiRackServerMasterName OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..48))
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This entry describes the name of the master server in a
|
||
|
rack-mounted uninterruptible power supply family. A slave
|
||
|
system would communicate with this server to derive UPS
|
||
|
status."
|
||
|
::= { cpqSiRackServer 2 }
|
||
|
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Video Group
|
||
|
-- ==============================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiVideo Group (1.3.6.1.4.1.232.2.2.7)
|
||
|
--
|
||
|
-- The Video group describes the manageable video displays that are
|
||
|
-- attached to the system.
|
||
|
--
|
||
|
-- Implementation of the video group is mandatory for all agents that
|
||
|
-- support the System Information MIB when a manageable video display
|
||
|
-- is in the system.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiVideoEdidRaw OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (128))
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The raw value returned from the video EDID function."
|
||
|
::= { cpqSiVideo 1 }
|
||
|
|
||
|
cpqSiVideoDesc OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The manufacturer and model description of the video display."
|
||
|
::= { cpqSiVideo 2 }
|
||
|
|
||
|
cpqSiVideoSerialNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..32))
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The serial number of the video display."
|
||
|
::= { cpqSiVideo 3 }
|
||
|
|
||
|
cpqSiVideoManufactureDate OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (7))
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The date of manufacture of the video display in the following
|
||
|
format:
|
||
|
|
||
|
field octets contents range
|
||
|
===== ====== ======= =====
|
||
|
1 1-2 year 0..65536
|
||
|
2 3 month 1..12
|
||
|
3 4 day 1..31
|
||
|
4 5 hour 0..23
|
||
|
5 6 minute 0..59
|
||
|
6 7 second 0..60
|
||
|
(use 60 for leap-second)
|
||
|
|
||
|
This field will be set to year = 0 if the agent cannot provide
|
||
|
the date. The date information that is given resolves to a year
|
||
|
and week, so the hour, minute, and second field will be set to 0,
|
||
|
the month and day fields will give the monday of the week of
|
||
|
manufacture."
|
||
|
::= { cpqSiVideo 4 }
|
||
|
|
||
|
cpqSiVideoHeight OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The maximum image height of the video display in centimeters"
|
||
|
::= { cpqSiVideo 5 }
|
||
|
|
||
|
cpqSiVideoWidth OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The maximum image width of the video display in centimeters"
|
||
|
::= { cpqSiVideo 6 }
|
||
|
|
||
|
|
||
|
cpqSiVideoMaxHorPixel OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The number of horizontal pixels in the highest resolution video
|
||
|
mode supported."
|
||
|
::= { cpqSiVideo 7 }
|
||
|
|
||
|
|
||
|
cpqSiVideoMaxVertPixel OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The number of vertical pixels in the highest resolution video
|
||
|
mode supported."
|
||
|
::= { cpqSiVideo 8 }
|
||
|
|
||
|
|
||
|
cpqSiVideoMaxRefreshRate OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS deprecated
|
||
|
DESCRIPTION
|
||
|
"The video refresh rate in Hz of the highest resolution video
|
||
|
mode supported."
|
||
|
::= { cpqSiVideo 9 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Monitor Group
|
||
|
-- ================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiMonitor Group (1.3.6.1.4.1.232.2.2.8)
|
||
|
--
|
||
|
-- The Monitor group describes all manageable video displays
|
||
|
-- that are attached to the system.
|
||
|
--
|
||
|
-- Implementation of the monitor group is mandatory for all agents that
|
||
|
-- support the Compaq System Information MIB when a manageable
|
||
|
-- video display is in the system.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiMonitorOverallCondition OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
degraded(3),
|
||
|
failed(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the overall condition of the system's
|
||
|
monitor(s).
|
||
|
|
||
|
The following conditions are supported:
|
||
|
|
||
|
other(1)
|
||
|
The monitor does not support fault reporting or condition is
|
||
|
unknown.
|
||
|
|
||
|
ok(2)
|
||
|
The monitor is operating OK.
|
||
|
|
||
|
degraded(3)
|
||
|
The monitor has detected a fault. The monitor is still useable
|
||
|
but action should be taken to return the monitor to ok.
|
||
|
|
||
|
failed(4)
|
||
|
The monitor has detected a fault. The monitor will not
|
||
|
be useable. Action should be taken to replace the monitor."
|
||
|
::= { cpqSiMonitor 1 }
|
||
|
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Monitor Group
|
||
|
-- ================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiMonitor Group (1.3.6.1.4.1.232.2.2.8)
|
||
|
-- cpqSiMonitorTable (1.3.6.1.4.1.232.2.2.8.2)
|
||
|
-- cpqSiMonitorEntry (1.3.6.1.4.1.232.2.2.8.2.1)
|
||
|
--
|
||
|
-- The Monitor Table describes all manageable video displays
|
||
|
-- that are attached to the system.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiMonitorTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiMonitorEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A table of all video monitor descriptions connected to this
|
||
|
system."
|
||
|
::= { cpqSiMonitor 2 }
|
||
|
|
||
|
cpqSiMonitorEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiMonitorEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A video monitor description."
|
||
|
INDEX { cpqSiMonitorIndex }
|
||
|
::= { cpqSiMonitorTable 1 }
|
||
|
|
||
|
CpqSiMonitorEntry ::= SEQUENCE {
|
||
|
cpqSiMonitorIndex INTEGER,
|
||
|
cpqSiMonitorEdidRaw OCTET STRING,
|
||
|
cpqSiMonitorDesc DisplayString,
|
||
|
cpqSiMonitorSerialNumber DisplayString,
|
||
|
cpqSiMonitorManufactureDate OCTET STRING,
|
||
|
cpqSiMonitorHeight INTEGER,
|
||
|
cpqSiMonitorWidth INTEGER,
|
||
|
cpqSiMonitorMaxHorPixel INTEGER,
|
||
|
cpqSiMonitorMaxVertPixel INTEGER,
|
||
|
cpqSiMonitorMaxRefreshRate INTEGER,
|
||
|
cpqSiMonitorManufacturer DisplayString,
|
||
|
cpqSiMonitorThermalCondition INTEGER,
|
||
|
cpqSiMonitorOperationalCondition INTEGER,
|
||
|
cpqSiMonitorStatus INTEGER
|
||
|
}
|
||
|
|
||
|
cpqSiMonitorIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..15)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A unique index for each video display connected to the system."
|
||
|
|
||
|
::= { cpqSiMonitorEntry 1 }
|
||
|
|
||
|
cpqSiMonitorEdidRaw OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (128))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The raw value returned from the video EDID function."
|
||
|
::= { cpqSiMonitorEntry 2 }
|
||
|
|
||
|
cpqSiMonitorDesc OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The manufacturer and model description of the video display."
|
||
|
::= { cpqSiMonitorEntry 3 }
|
||
|
|
||
|
cpqSiMonitorSerialNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..32))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The serial number of the video display."
|
||
|
::= { cpqSiMonitorEntry 4 }
|
||
|
|
||
|
cpqSiMonitorManufactureDate OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (7))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The date of manufacture of the video display in the following
|
||
|
format:
|
||
|
|
||
|
field octets contents range
|
||
|
===== ====== ======= =====
|
||
|
1 1-2 year 0..65536
|
||
|
2 3 month 1..12
|
||
|
3 4 day 1..31
|
||
|
4 5 hour 0..23
|
||
|
5 6 minute 0..59
|
||
|
6 7 second 0..60
|
||
|
(use 60 for leap-second)
|
||
|
|
||
|
This field will be set to year = 0 if the agent cannot provide
|
||
|
the date. The date information that is given resolves to a year
|
||
|
and week, so the hour, minute, and second field will be set to 0,
|
||
|
the month and day fields will give the monday of the week of
|
||
|
manufacture."
|
||
|
::= { cpqSiMonitorEntry 5 }
|
||
|
|
||
|
cpqSiMonitorHeight OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum image height of the video display in centimeters"
|
||
|
::= { cpqSiMonitorEntry 6}
|
||
|
|
||
|
cpqSiMonitorWidth OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The maximum image width of the video display in centimeters"
|
||
|
::= { cpqSiMonitorEntry 7 }
|
||
|
|
||
|
|
||
|
cpqSiMonitorMaxHorPixel OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of horizontal pixels in the highest resolution video
|
||
|
mode supported."
|
||
|
::= { cpqSiMonitorEntry 8 }
|
||
|
|
||
|
cpqSiMonitorMaxVertPixel OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of vertical pixels in the highest resolution video mode
|
||
|
supported."
|
||
|
::= { cpqSiMonitorEntry 9 }
|
||
|
|
||
|
cpqSiMonitorMaxRefreshRate OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The video refresh rate in Hz of the highest resolution video mode
|
||
|
supported."
|
||
|
::= { cpqSiMonitorEntry 10 }
|
||
|
|
||
|
cpqSiMonitorManufacturer OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The manufacturer of the video display."
|
||
|
::= { cpqSiMonitorEntry 11 }
|
||
|
|
||
|
cpqSiMonitorThermalCondition OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
degraded(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This provides the condition of the monitor's internal temperature.
|
||
|
|
||
|
This value will be one of the following:
|
||
|
|
||
|
other(1)
|
||
|
Monitor thermal fault reporting is not supported by this monitor
|
||
|
or the Insight Agent does not recognize the status. You may
|
||
|
need to upgrade your software.
|
||
|
|
||
|
ok(2)
|
||
|
The internal temperature is within normal limits.
|
||
|
|
||
|
degraded(3)
|
||
|
The internal temperature is outside normal operating range."
|
||
|
::= { cpqSiMonitorEntry 12 }
|
||
|
|
||
|
cpqSiMonitorOperationalCondition OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
degraded(3),
|
||
|
failed(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This provides the condition of the monitor's operational features.
|
||
|
|
||
|
This condition value will be one of the following:
|
||
|
|
||
|
other(1)
|
||
|
Monitor operational fault reporting is not supported by this
|
||
|
monitor or the Insight Agent does not recognize the status.
|
||
|
You may need to upgrade your software.
|
||
|
|
||
|
ok(2)
|
||
|
The monitor is operating within normal limits.
|
||
|
|
||
|
degraded(3)
|
||
|
The monitor is not functioning within normal operating limits.
|
||
|
At least one of the operational features has become degraded.
|
||
|
|
||
|
failed(4)
|
||
|
The monitor is not functioning within normal operating limits.
|
||
|
At least one of the operational features has failed causing the
|
||
|
monitor to not be usable. The monitor should be replaced."
|
||
|
::= { cpqSiMonitorEntry 13 }
|
||
|
|
||
|
cpqSiMonitorStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
unknown(2),
|
||
|
ok(3),
|
||
|
thermalDegraded(4),
|
||
|
operationalFailure(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This provides the status of the monitor's fault reporting features.
|
||
|
|
||
|
This status value will be one of the following:
|
||
|
|
||
|
other(1)
|
||
|
Monitor fault reporting is not supported by this monitor or the
|
||
|
Insight Agent does not recognize the status. You may need to
|
||
|
upgrade your software.
|
||
|
|
||
|
unknown(2)
|
||
|
The monitor status is unknown because the monitor is
|
||
|
either in power saving mode or it has been turned off.
|
||
|
|
||
|
ok(3)
|
||
|
The monitor is operating within normal limits.
|
||
|
|
||
|
thermalDegraded(4)
|
||
|
The monitor's internal temperature is not functioning within
|
||
|
normal operating limits.
|
||
|
|
||
|
operationalFailure(5)
|
||
|
The monitor is not functioning within normal operating limits.
|
||
|
At least one of the operational features has failed.
|
||
|
The monitor should be replaced."
|
||
|
|
||
|
::= { cpqSiMonitorEntry 14 }
|
||
|
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Hot Plug Slot Group
|
||
|
-- ======================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiHotPlugSlot Group (1.3.6.1.4.1.232.2.2.9)
|
||
|
--
|
||
|
-- The cpqSiHotPlugSlot group describes the System Information Hot Plug
|
||
|
-- slot information.
|
||
|
--
|
||
|
-- Implementation of the cpqSiHotPlugSlot group is mandatory for all
|
||
|
-- agents that support the System Information MIB.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiHotPlugSlotSupported OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
notSupported(2),
|
||
|
supported(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies if this system supports the Hot
|
||
|
Pluggable Slot feature."
|
||
|
::= { cpqSiHotPlugSlot 1 }
|
||
|
|
||
|
cpqSiHotPlugSlotCondition OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
degraded(3),
|
||
|
failed(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the overall condition of the Hot Plug
|
||
|
Slot feature.
|
||
|
|
||
|
The Hot Plug condition is set as follows:
|
||
|
|
||
|
other(1)
|
||
|
When Hot Plug Slots are not supported or condition is unknown.
|
||
|
|
||
|
ok(2)
|
||
|
If there are no hot plug slots with a condition of degraded
|
||
|
or failed.
|
||
|
|
||
|
degraded(3)
|
||
|
If there are degraded slot entries but none failed.
|
||
|
|
||
|
failed(4)
|
||
|
If there are failed slot entries."
|
||
|
::= { cpqSiHotPlugSlot 2 }
|
||
|
|
||
|
cpqSiHotPlugSlotChangeCount OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value will be incremented each time a hot plug event
|
||
|
occurs resulting in a change in the hot plug slot table."
|
||
|
::= { cpqSiHotPlugSlot 3 }
|
||
|
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Hot Plug Slot Table
|
||
|
-- ======================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiHotPlugSlot Group (1.3.6.1.4.1.232.2.2.9)
|
||
|
-- cpqSiHotPlugSlotTable (1.3.6.1.4.1.232.2.2.9.4)
|
||
|
--
|
||
|
-- The cpqSiHotPlugSlot group describes the manageable Hot Plug
|
||
|
-- Slots in the system. This table will be missing if the system does
|
||
|
-- not support hot plug slots.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiHotPlugSlotTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiHotPlugSlotEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of Hot Plug Slot information entries."
|
||
|
::= { cpqSiHotPlugSlot 4 }
|
||
|
|
||
|
cpqSiHotPlugSlotEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiHotPlugSlotEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A description of a Hot Plug Slot."
|
||
|
INDEX { cpqSiHotPlugSlotChassis, cpqSiHotPlugSlotIndex }
|
||
|
::= { cpqSiHotPlugSlotTable 1 }
|
||
|
|
||
|
CpqSiHotPlugSlotEntry ::= SEQUENCE {
|
||
|
cpqSiHotPlugSlotChassis INTEGER,
|
||
|
cpqSiHotPlugSlotIndex INTEGER,
|
||
|
cpqSiHotPlugSlotBoardPresent INTEGER,
|
||
|
cpqSiHotPlugSlotPowerState INTEGER,
|
||
|
cpqSiHotPlugSlotBoardCondition INTEGER,
|
||
|
cpqSiHotPlugSlotErrorStatus INTEGER,
|
||
|
cpqSiHotPlugSlotHwLocation DisplayString
|
||
|
}
|
||
|
|
||
|
cpqSiHotPlugSlotChassis OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Chassis where this hot plug slot resides."
|
||
|
::= { cpqSiHotPlugSlotEntry 1 }
|
||
|
|
||
|
cpqSiHotPlugSlotIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The slot within the chassis for this hot plug slot."
|
||
|
::= { cpqSiHotPlugSlotEntry 2 }
|
||
|
|
||
|
cpqSiHotPlugSlotBoardPresent OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
present(2),
|
||
|
absent(3),
|
||
|
presentButSuspended(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value indicates whether a board is present(2) in or
|
||
|
absent(3) from the slot. A value of other(1) indicates
|
||
|
the information could not be obtained."
|
||
|
::= { cpqSiHotPlugSlotEntry 3 }
|
||
|
|
||
|
cpqSiHotPlugSlotPowerState OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
powerOn(2),
|
||
|
powerOff(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value is set to powerOn(2) when power is being supplied
|
||
|
to the slot and powerOff(3) when power is not being supplied.
|
||
|
A value of other(1) indicates the information could not be
|
||
|
obtained."
|
||
|
::= { cpqSiHotPlugSlotEntry 4 }
|
||
|
|
||
|
cpqSiHotPlugSlotBoardCondition OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
degraded(3),
|
||
|
failed(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the condition of the hot plug slot.
|
||
|
|
||
|
The hot plug condition is set as follows:
|
||
|
|
||
|
other(1)
|
||
|
When the condition could not be determined.
|
||
|
|
||
|
ok(2)
|
||
|
The slot is powered up and operating normally.
|
||
|
|
||
|
degraded(3)
|
||
|
If the board in the slot is not fully functioning.
|
||
|
|
||
|
failed(4)
|
||
|
If the slot is failed for any reason. See the status code
|
||
|
for more information on the failure."
|
||
|
::= { cpqSiHotPlugSlotEntry 5 }
|
||
|
|
||
|
cpqSiHotPlugSlotErrorStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
noError(1),
|
||
|
generalError(2),
|
||
|
wrongRevision(3),
|
||
|
wrongBoard(4),
|
||
|
cannotConfig(5),
|
||
|
powerFault(6),
|
||
|
unexpectedPowerLoss(7),
|
||
|
wrongSpeed(8),
|
||
|
functionalFailure(9)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the status of the hot plug slot.
|
||
|
|
||
|
The hot plug slot status is set as follows:
|
||
|
|
||
|
noError(1)
|
||
|
The slot is operating normally.
|
||
|
|
||
|
generalError(2)
|
||
|
A general error occurred.
|
||
|
|
||
|
wrongRevision(3)
|
||
|
The revision of the replacement adapter was different from
|
||
|
the original adapter.
|
||
|
|
||
|
wrongBoard(4)
|
||
|
The model of the replacement adapter was different from the
|
||
|
original adapter.
|
||
|
|
||
|
cannotConfig(5)
|
||
|
The adapter could not be configured.
|
||
|
|
||
|
powerFault(6)
|
||
|
A power fault occurred for the slot.
|
||
|
|
||
|
unexpectedPowerLoss(7)
|
||
|
Power was unexpectedly lost from the slot.
|
||
|
|
||
|
wrongSpeed(8)
|
||
|
The adapter cannot be run at the current bus speed.
|
||
|
|
||
|
functionlFailure(9)
|
||
|
The adapter is not functioning correctly. This may
|
||
|
be caused by a cabling problem."
|
||
|
::= { cpqSiHotPlugSlotEntry 6 }
|
||
|
|
||
|
cpqSiHotPlugSlotHwLocation OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A text description of the hardware location, on complex
|
||
|
multi SBB hardware only, for the hot plug slot.
|
||
|
A NULL string indicates that the hardware location could not
|
||
|
be determined or is irrelevant."
|
||
|
::= { cpqSiHotPlugSlotEntry 7 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information System Battery Group
|
||
|
-- =======================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiSystemBattery Group (1.3.6.1.4.1.232.2.2.10)
|
||
|
--
|
||
|
-- The cpqSiSystemBattery group describes information about the system
|
||
|
-- (portable) batteries that are used to power your system. These
|
||
|
-- are the rechargeable batteries.
|
||
|
--
|
||
|
--
|
||
|
-- Implementation of the cpqSiBattery group is mandatory for all
|
||
|
-- agents that support the System Information MIB.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
|
||
|
cpqSiSystemBatteryOverallCondition OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
degraded(3),
|
||
|
failed(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the overall condition of all of the
|
||
|
system batteries.
|
||
|
|
||
|
The following conditions are supported:
|
||
|
|
||
|
other(1)
|
||
|
The system does not use system batteries or the battery
|
||
|
condition is unknown.
|
||
|
|
||
|
ok(2)
|
||
|
All System Batteries are operating OK.
|
||
|
|
||
|
degraded(3)
|
||
|
One or more of the System Batteries has degraded. The
|
||
|
degraded battery will continue to function but should be
|
||
|
replaced.
|
||
|
|
||
|
failed(4)
|
||
|
One of more of the System Batteries has failed. The failed
|
||
|
battery is no longer usable. Action should be taken to replace
|
||
|
the battery."
|
||
|
::= { cpqSiSystemBattery 1 }
|
||
|
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information System Battery Group
|
||
|
-- =======================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiSystemBattery Group (1.3.6.1.4.1.232.2.2.10)
|
||
|
-- cpqSiSystemBatteryTable (1.3.6.1.4.1.232.2.2.10.2)
|
||
|
-- cpqSiSystemBatteryEntry (1.3.6.1.4.1.232.2.2.10.2.1)
|
||
|
--
|
||
|
-- The System Battery Table describes asset, physical, and status
|
||
|
-- information about the portable batteries powering your system.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiSysBatteryTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiSysBatteryEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A table of System Batteries."
|
||
|
::= { cpqSiSystemBattery 2 }
|
||
|
|
||
|
cpqSiSysBatteryEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiSysBatteryEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A system battery description."
|
||
|
INDEX { cpqSiSysBatteryIndex }
|
||
|
::= { cpqSiSysBatteryTable 1 }
|
||
|
|
||
|
CpqSiSysBatteryEntry ::= SEQUENCE {
|
||
|
cpqSiSysBatteryIndex INTEGER,
|
||
|
cpqSiSysBatteryModel DisplayString,
|
||
|
cpqSiSysBatterySerialNum DisplayString,
|
||
|
cpqSiSysBatteryAssetTag DisplayString,
|
||
|
cpqSiSysBatteryManufacturer DisplayString,
|
||
|
cpqSiSysBatteryDate OCTET STRING,
|
||
|
cpqSiSysBatterySmartVersion DisplayString,
|
||
|
cpqSiSysBatteryCondition INTEGER,
|
||
|
cpqSiSysBatteryStatus INTEGER,
|
||
|
cpqSiSysBatteryChemistry INTEGER,
|
||
|
cpqSiSysBatteryRemainingCap INTEGER,
|
||
|
cpqSiSysBatteryFirmwareRevision INTEGER,
|
||
|
cpqSiSysBatteryHardwareRevision INTEGER,
|
||
|
cpqSiSysBatteryFullCap INTEGER,
|
||
|
cpqSiSysBatteryDesignCap INTEGER,
|
||
|
cpqSiSysBatteryHwLocation DisplayString
|
||
|
}
|
||
|
|
||
|
cpqSiSysBatteryIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A unique index for this battery entry."
|
||
|
::= { cpqSiSysBatteryEntry 1 }
|
||
|
|
||
|
|
||
|
cpqSiSysBatteryModel OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The model name for this battery."
|
||
|
::= { cpqSiSysBatteryEntry 2 }
|
||
|
|
||
|
cpqSiSysBatterySerialNum OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The serial number for this battery."
|
||
|
::= { cpqSiSysBatteryEntry 3 }
|
||
|
|
||
|
cpqSiSysBatteryAssetTag OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This is the customer changeable battery identifier that is set
|
||
|
to this system battery's serial number at the time of
|
||
|
manufacture.
|
||
|
|
||
|
The string will be empty if the battery does support
|
||
|
this function."
|
||
|
::= { cpqSiSysBatteryEntry 4 }
|
||
|
|
||
|
cpqSiSysBatteryManufacturer OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The battery's manufacturer's name.
|
||
|
|
||
|
The string will be empty if the battery does support
|
||
|
this function."
|
||
|
::= { cpqSiSysBatteryEntry 5 }
|
||
|
|
||
|
|
||
|
cpqSiSysBatteryDate OBJECT-TYPE
|
||
|
SYNTAX OCTET STRING (SIZE (7))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The battery's manufacture date.
|
||
|
|
||
|
field octets contents range
|
||
|
===== ====== ======= =====
|
||
|
1 1-2 year 0..65536
|
||
|
2 3 month 1..12
|
||
|
3 4 day 1..31
|
||
|
4 5 hour 0..23
|
||
|
5 6 minute 0..59
|
||
|
6 7 second 0..60
|
||
|
(use 60 for leap-second)
|
||
|
|
||
|
This field will be set to year = 0 if the agent cannot provide
|
||
|
the module date. The hour, minute, and second field will be set
|
||
|
to zero (0) if they are not relevant. The year field is set
|
||
|
with the most significant octet first.
|
||
|
|
||
|
The string will be empty if the battery does support
|
||
|
this function."
|
||
|
::= { cpqSiSysBatteryEntry 6 }
|
||
|
|
||
|
cpqSiSysBatterySmartVersion OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The Smart Battery Data Specification version number supported by this
|
||
|
battery.
|
||
|
|
||
|
The string will be empty if the system battery does support
|
||
|
this function."
|
||
|
::= { cpqSiSysBatteryEntry 7 }
|
||
|
|
||
|
cpqSiSysBatteryCondition OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
degraded(3),
|
||
|
failed(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This provides the current condition of this system battery.
|
||
|
|
||
|
The following status values are supported:
|
||
|
|
||
|
other(1)
|
||
|
The battery does not support condition monitoring or
|
||
|
the Insight Agent cannot determine condition.
|
||
|
|
||
|
ok(2)
|
||
|
The battery is operating normally. No user action is
|
||
|
required.
|
||
|
|
||
|
degraded(3)
|
||
|
The battery is degraded. The battery is still usable
|
||
|
but should be replaced.
|
||
|
|
||
|
failed(4)
|
||
|
The battery has failed. The battery is no longer
|
||
|
usable and should be replaced soon."
|
||
|
::= { cpqSiSysBatteryEntry 8 }
|
||
|
|
||
|
cpqSiSysBatteryStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
capacityDegraded(3),
|
||
|
chargeFault(4),
|
||
|
batteryFailure(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This provides the current status of the battery.
|
||
|
|
||
|
The following status values are supported:
|
||
|
|
||
|
other(1):
|
||
|
This battery does not support status reporting.
|
||
|
|
||
|
ok(2):
|
||
|
The battery is operating ok.
|
||
|
|
||
|
User Action: No action required.
|
||
|
|
||
|
capacityDegraded(3):
|
||
|
Significant battery degradation has occurred.
|
||
|
The battery can no longer be fully recharged.
|
||
|
|
||
|
User Action:
|
||
|
If using multiple batteries, run the Power
|
||
|
Conservation Utility to identify the battery
|
||
|
location. Contact your System Administrator or
|
||
|
Authorized Reseller to order a replacement
|
||
|
battery.
|
||
|
|
||
|
chargeFault(4):
|
||
|
One or more batteries are not functioning properly.
|
||
|
|
||
|
User Action:
|
||
|
Make sure all batteries are operating in the
|
||
|
recommended temperature range. Check for foreign
|
||
|
objects in the battery slots. Remove and reinsert all
|
||
|
batteries to resume normal battery operation.
|
||
|
Contact your System Administrator or Authorized
|
||
|
Reseller if you are still experiencing problems.
|
||
|
|
||
|
batteryFailure(5):
|
||
|
The battery has failed and must be replaced.
|
||
|
|
||
|
User Action:
|
||
|
Contact your System Administrator or Authorized
|
||
|
Reseller to order a replacement battery. Recycle your
|
||
|
old battery. For proper disposal information, refer
|
||
|
to the documentation that came with your computer."
|
||
|
|
||
|
::= { cpqSiSysBatteryEntry 9 }
|
||
|
|
||
|
cpqSiSysBatteryChemistry OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
unknown(2),
|
||
|
lead-Acid(3),
|
||
|
nickel-Cadmium(4),
|
||
|
nickel-Metal-Hydride(5),
|
||
|
lithium-Ion(6),
|
||
|
zinc-Air(7),
|
||
|
lithium-Polymer(8)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The chemistry of the battery."
|
||
|
|
||
|
::= { cpqSiSysBatteryEntry 10 }
|
||
|
|
||
|
cpqSiSysBatteryRemainingCap OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This is a percentage of the battery's remaining capacity
|
||
|
from its design capacity.
|
||
|
|
||
|
If this attribute is not supported, 65535 is returned."
|
||
|
::= { cpqSiSysBatteryEntry 11 }
|
||
|
|
||
|
cpqSiSysBatteryFirmwareRevision OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This is the revision level of the firmware on the battery.
|
||
|
|
||
|
If this attribute is not supported, 255 is returned."
|
||
|
::= { cpqSiSysBatteryEntry 12 }
|
||
|
|
||
|
cpqSiSysBatteryHardwareRevision OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..255)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This is the revision level of the hardware on the battery.
|
||
|
|
||
|
If this attribute is not supported, 255 is returned."
|
||
|
::= { cpqSiSysBatteryEntry 13 }
|
||
|
|
||
|
cpqSiSysBatteryFullCap OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This is the mWatt-Hours of the battery's Full capacity on
|
||
|
the current charge.
|
||
|
|
||
|
If this attribute is not supported, 65535 is returned."
|
||
|
::= { cpqSiSysBatteryEntry 14 }
|
||
|
|
||
|
cpqSiSysBatteryDesignCap OBJECT-TYPE
|
||
|
SYNTAX INTEGER (0..65535)
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This is the mWatt-Hours of the battery's design capacity as
|
||
|
specified by the manufacturer.
|
||
|
|
||
|
If this attribute is not supported, 65535 is returned."
|
||
|
::= { cpqSiSysBatteryEntry 15 }
|
||
|
|
||
|
cpqSiSysBatteryHwLocation OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"A text description of the hardware location, on complex
|
||
|
multi SBB hardware only, for the battery.
|
||
|
A NULL string indicates that the hardware location could not
|
||
|
be determined or is irrelevant."
|
||
|
::= { cpqSiSysBatteryEntry 16 }
|
||
|
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Docking Station Group
|
||
|
-- ========================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiDockingStation Group (1.3.6.1.4.1.232.2.2.11)
|
||
|
--
|
||
|
-- The cpqsiDockingStation group describes the asset information
|
||
|
-- about portable docking stations.
|
||
|
--
|
||
|
--
|
||
|
-- Implementation of the cpqSiDockingStation group is mandatory for all
|
||
|
-- agents that support the System Information MIB.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiDockingStationStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
notSupported(1),
|
||
|
docked(2),
|
||
|
undocked(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the connection of the computer
|
||
|
system to a docking station.
|
||
|
|
||
|
The following connection states are supported:
|
||
|
|
||
|
notSupported(1)
|
||
|
This system does not interface to a docking station.
|
||
|
|
||
|
docked(2)
|
||
|
This system is connected to a docking station.
|
||
|
|
||
|
undocked(3)
|
||
|
This system is not connect to a docking station."
|
||
|
::= { cpqSiDockingStation 1}
|
||
|
|
||
|
cpqSiDockingStationSerialNum OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The serial number of the docking station.
|
||
|
|
||
|
The string will be empty if the docking station does not support a
|
||
|
serial or the system does not interface to a docking station."
|
||
|
::= { cpqSiDockingStation 2 }
|
||
|
|
||
|
cpqSiDockingStationModel OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The model name of the docking station.
|
||
|
|
||
|
The string will be empty if the docking station does not report the
|
||
|
model name or the system does not interface to a docking station."
|
||
|
::= { cpqSiDockingStation 3 }
|
||
|
|
||
|
cpqSiDockingStationAssetTag OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This is a customer changeable identifier that is set to the docking
|
||
|
station serial number at the time of manufacture.
|
||
|
|
||
|
The string will be empty if the docking station does not report an
|
||
|
asset tag or the system does not interface to a docking station."
|
||
|
::= { cpqSiDockingStation 4}
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information FRU Group
|
||
|
-- ============================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiFru Group (1.3.6.1.4.1.232.2.2.12)
|
||
|
--
|
||
|
-- The cpqsiFru group describes the Field Replaceable Units in the
|
||
|
-- server system.
|
||
|
--
|
||
|
--
|
||
|
-- Implementation of the cpqSiFru group is mandatory for all
|
||
|
-- Server Agents that support the System Information MIB.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiFruTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiFruEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Table of Field Replaceable Units of system, providing
|
||
|
inventory and asset control information. This table is
|
||
|
referenced from logical hardware descriptions elsewhere in
|
||
|
the MIB."
|
||
|
::= { cpqSiFru 1 }
|
||
|
|
||
|
cpqSiFruEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiFruEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Each entry represents a Field Replaceable Unit (FRU) of hardware."
|
||
|
INDEX { cpqSiFruIndex }
|
||
|
::= { cpqSiFruTable 1 }
|
||
|
|
||
|
CpqSiFruEntry ::=
|
||
|
SEQUENCE {
|
||
|
cpqSiFruIndex INTEGER,
|
||
|
cpqSiFruType INTEGER,
|
||
|
cpqSiFruDescr DisplayString,
|
||
|
cpqSiFruVendor DisplayString,
|
||
|
cpqSiFruPartNumber DisplayString,
|
||
|
cpqSiFruRevision DisplayString,
|
||
|
cpqSiFruFirmwareRevision DisplayString,
|
||
|
cpqSiFruSerialNumber DisplayString,
|
||
|
cpqSiFruAssetNo DisplayString,
|
||
|
cpqSiFruClass INTEGER,
|
||
|
cpqSiFruSlotNumber DisplayString,
|
||
|
cpqSiFruSubAssemblyNumber INTEGER,
|
||
|
cpqSiFruAssemblyNumber INTEGER,
|
||
|
cpqSiFruChassisNumber INTEGER,
|
||
|
cpqSiFruPositionNumber INTEGER,
|
||
|
cpqSiFruCabinetIDNumber INTEGER,
|
||
|
cpqSiFruSiteLocation INTEGER,
|
||
|
cpqSiFruDiagStatus INTEGER,
|
||
|
cpqSiFruExtendedDiagStatus INTEGER,
|
||
|
cpqSiFruCellTablePtr INTEGER,
|
||
|
cpqSiFruIOCTablePtr INTEGER,
|
||
|
cpqSiFruFileId DisplayString,
|
||
|
cpqSiFruScanRev DisplayString
|
||
|
}
|
||
|
|
||
|
cpqSiFruIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A locally-unique index value."
|
||
|
::= { cpqSiFruEntry 1 }
|
||
|
|
||
|
cpqSiFruType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown(1) ,
|
||
|
other(2) ,
|
||
|
motherBoard(3) ,
|
||
|
processor(4) ,
|
||
|
memoryCard(5) ,
|
||
|
memoryModule(6) ,
|
||
|
peripheralDevice(7) ,
|
||
|
systemBusBridge(8) ,
|
||
|
powerSupply(9) ,
|
||
|
chassis(10) ,
|
||
|
fan(11) ,
|
||
|
ioCard(12)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"General category of the type of FRU that this is."
|
||
|
::= { cpqSiFruEntry 2 }
|
||
|
|
||
|
cpqSiFruDescr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"More detailed description of FRU type, if known."
|
||
|
::= { cpqSiFruEntry 3 }
|
||
|
|
||
|
cpqSiFruVendor OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Manufacturer name or ID."
|
||
|
::= { cpqSiFruEntry 4 }
|
||
|
|
||
|
cpqSiFruPartNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Number by which this unit is orderable."
|
||
|
::= { cpqSiFruEntry 5 }
|
||
|
|
||
|
cpqSiFruRevision OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Version number of this unit. If artwork level is available, it will
|
||
|
appear as 'Artwork: XXX' following FRU version portion."
|
||
|
::= { cpqSiFruEntry 6 }
|
||
|
|
||
|
cpqSiFruFirmwareRevision OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The revision of the firmware, if any. Otherwise null."
|
||
|
::= { cpqSiFruEntry 7 }
|
||
|
|
||
|
cpqSiFruSerialNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The serial number of this unit's instance."
|
||
|
::= { cpqSiFruEntry 8 }
|
||
|
|
||
|
cpqSiFruAssetNo OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The asset number for this unit. This string may be limited."
|
||
|
::= { cpqSiFruEntry 9 }
|
||
|
|
||
|
cpqSiFruClass OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown(1) ,
|
||
|
other(2) ,
|
||
|
currentBoardInSlot(3) ,
|
||
|
priorBoardInSlot(4) ,
|
||
|
parentBoard(5) ,
|
||
|
priorParentBoard(6) ,
|
||
|
priorParentSystem(7)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Represents the status category of the unit."
|
||
|
::= { cpqSiFruEntry 10 }
|
||
|
|
||
|
cpqSiFruSlotNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Physical slot number of FRU."
|
||
|
::= { cpqSiFruEntry 11 }
|
||
|
|
||
|
cpqSiFruSubAssemblyNumber OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Subassembly containing this FRU. From FRU V5.0."
|
||
|
::= { cpqSiFruEntry 12 }
|
||
|
|
||
|
cpqSiFruAssemblyNumber OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Assembly containing this FRU. From FRU V5.0."
|
||
|
::= { cpqSiFruEntry 13 }
|
||
|
|
||
|
cpqSiFruChassisNumber OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Chassis containing this FRU. From FRU V5.0."
|
||
|
::= { cpqSiFruEntry 14 }
|
||
|
|
||
|
cpqSiFruPositionNumber OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Position in Chassis to help locate FRU. From FRU V5.0."
|
||
|
::= { cpqSiFruEntry 15 }
|
||
|
|
||
|
cpqSiFruCabinetIDNumber OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Cabinet number containing this FRU. From FRU V5.0."
|
||
|
::= { cpqSiFruEntry 16 }
|
||
|
|
||
|
cpqSiFruSiteLocation OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Site code for system containing this FRU. From FRU V5.0."
|
||
|
::= { cpqSiFruEntry 17 }
|
||
|
|
||
|
cpqSiFruDiagStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown(1),
|
||
|
ok(2),
|
||
|
degraded(3),
|
||
|
failed(4),
|
||
|
disabled(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Use system status values to describe current state of the
|
||
|
FRU."
|
||
|
::= { cpqSiFruEntry 18 }
|
||
|
|
||
|
cpqSiFruExtendedDiagStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Diagnostic Status value returned by Device Specific
|
||
|
diagnostics. Usually through a diagnostic status register
|
||
|
on the device. See product manual for bit descriptions."
|
||
|
::= { cpqSiFruEntry 19 }
|
||
|
|
||
|
cpqSiFruCellTablePtr OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Index for the cell in cpqSeCellTable where this FRU is physically located."
|
||
|
::= { cpqSiFruEntry 20 }
|
||
|
|
||
|
cpqSiFruIOCTablePtr OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Index for the I/O Chassis in cpqSeIOCTablePtr where this FRU is physically located"
|
||
|
::= { cpqSiFruEntry 21 }
|
||
|
|
||
|
cpqSiFruFileId OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This represents the FRU file identifier"
|
||
|
::= { cpqSiFruEntry 22 }
|
||
|
|
||
|
cpqSiFruScanRev OBJECT-TYPE
|
||
|
SYNTAX DisplayString (SIZE (0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This represents FRU scan revision"
|
||
|
::= { cpqSiFruEntry 23 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Rack and Enclosure Group
|
||
|
-- ===========================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiRackEnclosure Group (1.3.6.1.4.1.232.2.2.13)
|
||
|
--
|
||
|
-- The cpqSiRackEnclosure group indicates the availability of rack and/or
|
||
|
-- enclosure based systems.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiRackEnclosureMgrTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF CpqSiRackEnclosureMgrEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Table of possible rack and/or enclosure based systems."
|
||
|
::= { cpqSiRackEnclosure 1 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrEntry OBJECT-TYPE
|
||
|
SYNTAX CpqSiRackEnclosureMgrEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A entry for a rack and/or enclosure based system."
|
||
|
INDEX { cpqSiRackEnclosureMgrIndex }
|
||
|
::= { cpqSiRackEnclosureMgrTable 1 }
|
||
|
|
||
|
CpqSiRackEnclosureMgrEntry ::=
|
||
|
SEQUENCE {
|
||
|
cpqSiRackEnclosureMgrIndex INTEGER,
|
||
|
cpqSiRackEnclosureMgrType INTEGER,
|
||
|
cpqSiRackEnclosureMgrIpAddr DisplayString,
|
||
|
cpqSiRackEnclosureMgrWebLink DisplayString,
|
||
|
cpqSiRackEnclosureMgrCondition INTEGER,
|
||
|
cpqSiRackEnclosureMgrSerialNumber DisplayString,
|
||
|
cpqSiRackEnclosureMgrModel DisplayString,
|
||
|
cpqSiRackEnclosureMgrName DisplayString,
|
||
|
cpqSiRackEnclosureMgrFwRev DisplayString,
|
||
|
cpqSiRackEnclosureMgrProductID DisplayString,
|
||
|
cpqSiRackEnclosureMgrUUID DisplayString,
|
||
|
cpqSiRackEnclosureMgrMatrix INTEGER,
|
||
|
cpqSiRackEnclosureMgrMatrixID DisplayString
|
||
|
}
|
||
|
|
||
|
cpqSiRackEnclosureMgrIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A locally-unique index value."
|
||
|
::= { cpqSiRackEnclosureMgrEntry 1 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
noEnclosureManagement(2),
|
||
|
enclosureManagement(3),
|
||
|
onboardAdminManagement(4),
|
||
|
multiboardchassis(5)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"This value specifies the type of enclosure management.
|
||
|
|
||
|
other(1)
|
||
|
When the type not be determined.
|
||
|
|
||
|
noEnclosureManagement(2)
|
||
|
The server is part of a rack/enclosure managed system, but there
|
||
|
is no dedicated enclosure manager.
|
||
|
|
||
|
enclosureManagement(3)
|
||
|
The server is part of a rack/enclosure managed system with a
|
||
|
dedicated enclosure manager.
|
||
|
|
||
|
onboardAdminManagement(4)
|
||
|
The server is part of a rack/enclosure managed system with a
|
||
|
onboard Administrator.
|
||
|
|
||
|
multiboardchassis(5)
|
||
|
The server is part of a nultiple board chassis. "
|
||
|
::= { cpqSiRackEnclosureMgrEntry 2 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrIpAddr OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The IP address of the rack enclosure manager.
|
||
|
|
||
|
The string will be empty if the enclosure does not report the
|
||
|
information or it could not be determined."
|
||
|
::= { cpqSiRackEnclosureMgrEntry 3 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrWebLink OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The web link to the enclosure managers web based management
|
||
|
information for the enclosure.
|
||
|
|
||
|
The string will be empty if the enclosure does not report the
|
||
|
information or it could not be determined."
|
||
|
::= { cpqSiRackEnclosureMgrEntry 4 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrCondition OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
ok(2),
|
||
|
degraded(3),
|
||
|
failed(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The overall condition of the Enclosure. For more detailed
|
||
|
status information, follow the cpqSiEnclosureMgrWebLink through
|
||
|
the Web Management Agent interface.
|
||
|
|
||
|
other(1)
|
||
|
This is the default condition for systems when
|
||
|
cpqSiRackEnclosureMgrType has a value of
|
||
|
noEnclosureManagement(2).
|
||
|
|
||
|
When cpqSiRackEnclosureMgrType has a value of
|
||
|
enclosureManagement(3), this indicates the status of the
|
||
|
enclosure manager could not be determined.
|
||
|
|
||
|
ok(2)
|
||
|
The enclosure manager is in an ok state. Follow the
|
||
|
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
|
||
|
to manage the enclosure.
|
||
|
|
||
|
degraded(3)
|
||
|
The enclosure manager is in a degraded state. Follow the
|
||
|
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
|
||
|
to manage the enclosure.
|
||
|
|
||
|
failed(4)
|
||
|
The enclosure manager is in a failed state. Follow the
|
||
|
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
|
||
|
to manage the enclosure."
|
||
|
::= { cpqSiRackEnclosureMgrEntry 5 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrSerialNumber OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The serial number of the enclosure.
|
||
|
|
||
|
The string will be empty if the enclosure does not report the
|
||
|
information or it could not be determined."
|
||
|
::= { cpqSiRackEnclosureMgrEntry 6 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrModel OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The model name of the enclosure.
|
||
|
The string will be empty if it could not be determined."
|
||
|
::= { cpqSiRackEnclosureMgrEntry 7 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrName OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The name of the enclosure. This name logically groups together the
|
||
|
Blade servers installed in the same enclosure and it is shared
|
||
|
with the other servers in the enclosure.
|
||
|
The string will be empty if it could not be determined."
|
||
|
::= { cpqSiRackEnclosureMgrEntry 8 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrFwRev OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The Firmware revision of the Enclosure Manager/Onboard Administrator.
|
||
|
The string will be empty if it could not be determined."
|
||
|
::= { cpqSiRackEnclosureMgrEntry 9 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrProductID OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The Enclosure product identifier. The string will be empty
|
||
|
if it could not be determined."
|
||
|
::= { cpqSiRackEnclosureMgrEntry 10 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrUUID OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The Enclosure unique identifier. The string will be empty
|
||
|
if it could not be determined."
|
||
|
::= { cpqSiRackEnclosureMgrEntry 11 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrMatrix OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
" Value 0 not configured in a BladeSystem Matrix environment.
|
||
|
1 configured in a BladeSystem Matrix environment."
|
||
|
::= { cpqSiRackEnclosureMgrEntry 12 }
|
||
|
|
||
|
cpqSiRackEnclosureMgrMatrixID OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
" Value BladeSystem Matrix vX.Y.Z Where
|
||
|
X major version.
|
||
|
Y minor version.
|
||
|
Z update version.
|
||
|
Is only valid if cpqSiRackEnclosureMgrMatrix value is a 1.
|
||
|
By default is NULL"
|
||
|
::= { cpqSiRackEnclosureMgrEntry 13 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Server Blade Group
|
||
|
-- ===========================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiServerBlade Group (1.3.6.1.4.1.232.2.2.14)
|
||
|
--
|
||
|
-- The cpqsiServerBlade group describes the server Blade system.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiServerBladeEnclosureBayNumber OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"This value specifies the enclosure bay number occupied by the blade.
|
||
|
In case of a blade occupying multiple bays, this will be the lowest
|
||
|
enclosure bay number of all the bay numbers occupied by this balde"
|
||
|
::= { cpqSiServerBlade 1 }
|
||
|
|
||
|
cpqSiServerBladeHeight OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown(1),
|
||
|
halfHeightBlade(2),
|
||
|
fullHeightBlade(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Blade height is the Blade length.
|
||
|
|
||
|
unknown(1)
|
||
|
This indicates it could not be determined.
|
||
|
|
||
|
halfHeightBlade(2)
|
||
|
This indicates a half-height server Blade.
|
||
|
|
||
|
fullHeightBlade(3)
|
||
|
This indicates a full-height server Blade."
|
||
|
|
||
|
::= { cpqSiServerBlade 2 }
|
||
|
|
||
|
cpqSiServerBladeWidth OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown(1),
|
||
|
singleWide(2),
|
||
|
doubleWide(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"Width of the Blade in terms of Enclosure Bays. This pertain to the
|
||
|
Blade side that connects to the enclosure backplane."
|
||
|
::= { cpqSiServerBlade 3 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information Rack Group
|
||
|
-- ===========================================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiRack Group (1.3.6.1.4.1.232.2.2.15)
|
||
|
--
|
||
|
-- The cpqSiRack group describes the rack details.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiRackName OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The rack name. This name is used to logically group together
|
||
|
enclosures in a rack and it is shared with other enclosures
|
||
|
in the rack.
|
||
|
The string will be empty if it could not be determined."
|
||
|
::= { cpqSiRack 1 }
|
||
|
|
||
|
cpqSiRackUUID OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The rack unique identifier. The string will be empty
|
||
|
if it could be determined."
|
||
|
::= { cpqSiRack 2 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Information MP Group
|
||
|
-- ==============================
|
||
|
--
|
||
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
|
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
|
||
|
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
|
||
|
-- cpqSiMP Group (1.3.6.1.4.1.232.2.2.16)
|
||
|
--
|
||
|
-- The cpqSiMP group contains information about the Management Processor.
|
||
|
--
|
||
|
-- ****************************************************************************
|
||
|
|
||
|
cpqSiMPHostName OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The host name of the Management Processor.
|
||
|
The string will be empty if it could not be determined."
|
||
|
::= { cpqSiMP 1 }
|
||
|
|
||
|
cpqSiMPHealthStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unknown(1),
|
||
|
ok(2),
|
||
|
degraded(3),
|
||
|
failed(4)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS optional
|
||
|
DESCRIPTION
|
||
|
"The health status of the Management Processor."
|
||
|
::= { cpqSiMP 2 }
|
||
|
|
||
|
-- ****************************************************************************
|
||
|
-- System Info MIB Trap Definitions
|
||
|
-- ================================
|
||
|
--
|
||
|
-- The SNMP trap messages must not be bigger than 484 octets (bytes).
|
||
|
--
|
||
|
-- Trap support in an SNMP agent implementation is optional. An SNMP
|
||
|
-- agent implementation may support all, some, or none of the traps.
|
||
|
-- If traps are supported, The user should be provided with the option of
|
||
|
-- disabling traps.
|
||
|
-- **************************************************************************
|
||
|
|
||
|
cpqSiHoodRemoved TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags }
|
||
|
DESCRIPTION
|
||
|
"System hood is removed.
|
||
|
|
||
|
The hood status has been set to removed. The
|
||
|
system's hood is not in a properly installed state. This
|
||
|
situation may result in improper cooling of the system due
|
||
|
to air flow changes caused by the missing hood.
|
||
|
|
||
|
User Action: Replace the cover (hood), ensure the system's cover
|
||
|
is properly installed. Verify the system is in working order."
|
||
|
|
||
|
--#TYPE "System hood is removed (2001)"
|
||
|
--#SUMMARY "Hood is removed from unit."
|
||
|
--#ARGUMENTS {}
|
||
|
--#SEVERITY MAJOR
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE DEGRADED
|
||
|
--#SIMPLE_SEVERITY MAJOR
|
||
|
--#HWSTATUS_CATEGORY NONE
|
||
|
--#ACTION "Replace the cover, ensuring it is properly installed. Verify the system is in working order."
|
||
|
|
||
|
::= 2001
|
||
|
|
||
|
cpqSiMonitorConditionOK TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
|
||
|
DESCRIPTION
|
||
|
"Fault reporting features have returned to within their normal
|
||
|
operating range for the monitor indicated by cpqSiMonitorIndex.
|
||
|
The monitor's condition has been set to OK.
|
||
|
|
||
|
User Action: None."
|
||
|
|
||
|
--#TYPE "Monitor Condition OK (2002)"
|
||
|
--#SUMMARY "The monitor's condition has been set to OK."
|
||
|
--#ARGUMENTS {}
|
||
|
--#SEVERITY INFORMATIONAL
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE OPERATIONAL
|
||
|
--#SIMPLE_SEVERITY OK
|
||
|
--#HWSTATUS_CATEGORY NONE
|
||
|
::= 2002
|
||
|
|
||
|
|
||
|
cpqSiMonitorConditionDegraded TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
|
||
|
DESCRIPTION
|
||
|
"A fault reporting feature has exceeded normal limits for
|
||
|
the monitor indicated by the cpqSiMonitorIndex. The monitor's
|
||
|
condition is degraded due to the internal temperature exceeding
|
||
|
normal operating limits. The monitor is still useable, but
|
||
|
action should be taken to return the condition to OK.
|
||
|
|
||
|
User Action: Physically check for obstructions to air flow around
|
||
|
the monitor. Check the thermostat in the room that the system
|
||
|
occupies. Allow the monitor to cool by turning off the monitor
|
||
|
for 5 minutes then turn the monitor back on. After the monitor
|
||
|
cools, another alarm indicating an improving condition, such as
|
||
|
Monitor OK, will be issued."
|
||
|
|
||
|
--#TYPE "Monitor Condition Degraded (2003)"
|
||
|
--#SUMMARY "The monitor's condition has been set to degraded."
|
||
|
--#ARGUMENTS {}
|
||
|
--#SEVERITY MINOR
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE DEGRADED
|
||
|
--#SIMPLE_SEVERITY MAJOR
|
||
|
--#HWSTATUS_CATEGORY NONE
|
||
|
|
||
|
::= 2003
|
||
|
|
||
|
cpqSiMonitorConditionFailed TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
|
||
|
DESCRIPTION
|
||
|
"A fault reporting feature has exceeded normal limits in the
|
||
|
monitor indicated by the cpqSiMonitorIndex. The monitor's
|
||
|
condition has been set to failed due to an operational feature
|
||
|
exceeding normal operating limits. The monitor will not be
|
||
|
useable and should be replaced.
|
||
|
|
||
|
User Action: Make a note of the monitor model number and serial
|
||
|
number. Replace the monitor.
|
||
|
|
||
|
Refer to the appropriate Maintenance and Service Guide for
|
||
|
detailed information on a component replacement."
|
||
|
|
||
|
--#TYPE "Monitor Condition Failed (2004)"
|
||
|
--#SUMMARY "The monitor's condition has been set to failed."
|
||
|
--#ARGUMENTS {}
|
||
|
--#SEVERITY CRITICAL
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE NONOPERATIONAL
|
||
|
--#SIMPLE_SEVERITY CRITICAL
|
||
|
--#HWSTATUS_CATEGORY NONE
|
||
|
--#ACTION "Replace the failed monitor."
|
||
|
|
||
|
::= 2004
|
||
|
|
||
|
cpqSiCorrMemErrStatusDegraded TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMemErrorIndex }
|
||
|
DESCRIPTION
|
||
|
"Correctable memory error count has exceeded the threshold for the
|
||
|
memory module indicated by the 'cpqSiMemErrorIndex' variable.
|
||
|
The appropriate cpqSiMemModuleECCStatus has been set to degraded.
|
||
|
|
||
|
User Action: For Desktops, the System Administrator should run
|
||
|
the F10 Diagnostics on this system and select RAM LONG TEST. If
|
||
|
it is determined that a module needs replacing, schedule
|
||
|
maintenance for the system and replace the failed memory module.
|
||
|
|
||
|
Refer to the appropriate Maintenance and Service Guide for detailed
|
||
|
information on a component replacement."
|
||
|
|
||
|
--#TYPE "Excessive Correctable Memory Errors (2005)"
|
||
|
--#SUMMARY "The memory module %d ECC status has been set to degraded."
|
||
|
--#ARGUMENTS {3}
|
||
|
--#SEVERITY MINOR
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE DEGRADED
|
||
|
--#SIMPLE_SEVERITY MAJOR
|
||
|
--#HWSTATUS_CATEGORY MEMORY
|
||
|
--#ACTION "Schedule maintenance for the system and replace the failing memory module."
|
||
|
|
||
|
::= 2005
|
||
|
|
||
|
cpqSiCorrMemErrStatusOk TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMemErrorIndex }
|
||
|
DESCRIPTION
|
||
|
"Correctable memory error count is now below the threshold for the
|
||
|
memory module indicated by the 'cpqSiMemErrorIndex' variable. The
|
||
|
appropriate cpqSiMemModuleECCStatus has been set to ok.
|
||
|
|
||
|
User Action: None."
|
||
|
|
||
|
--#TYPE "Correctable Memory Errors Count OK (2006)"
|
||
|
--#SUMMARY "The memory module %d ECC status has been set to ok."
|
||
|
--#ARGUMENTS {3}
|
||
|
--#SEVERITY INFORMATIONAL
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE OPERATIONAL
|
||
|
--#SIMPLE_SEVERITY OK
|
||
|
--#HWSTATUS_CATEGORY MEMORY
|
||
|
|
||
|
::= 2006
|
||
|
|
||
|
cpqSiMemConfigChange TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMemConfigChangeData }
|
||
|
DESCRIPTION
|
||
|
"A memory configuration change has occurred. CpqSiMemConfigChangeData
|
||
|
will indicate which memory modules slots have changed.
|
||
|
|
||
|
User Action: You may want to verify a valid reason for a memory
|
||
|
configuration to have occurred. If system issuing the alert is
|
||
|
a Desktop running NT, the memory configuration change information
|
||
|
is also logged in the NT System Log."
|
||
|
|
||
|
--#TYPE "Memory modules have changed (2007)"
|
||
|
--#SUMMARY "The system's memory configuration has changed."
|
||
|
--#ARGUMENTS {}
|
||
|
--#SEVERITY INFORMATIONAL
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE OPERATIONAL
|
||
|
--#SIMPLE_SEVERITY OK
|
||
|
--#HWSTATUS_CATEGORY MEMORY
|
||
|
::= 2007
|
||
|
|
||
|
cpqSiHotPlugSlotBoardRemoved TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiHotPlugSlotChassis,
|
||
|
cpqSiHotPlugSlotIndex }
|
||
|
DESCRIPTION
|
||
|
"Hot Plug Slot Board Removed.
|
||
|
|
||
|
A Hot Plug Slot Board has been removed from the specified
|
||
|
chassis and slot.
|
||
|
|
||
|
User Action: None."
|
||
|
|
||
|
--#TYPE "Hot Plug Slot Board Removed (2008)"
|
||
|
--#SUMMARY "Hot plug slot board removed from chassis %d, slot %d."
|
||
|
--#ARGUMENTS {2, 3}
|
||
|
--#SEVERITY INFORMATIONAL
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE OPERATIONAL
|
||
|
--#SIMPLE_SEVERITY OK
|
||
|
--#HWSTATUS_CATEGORY NONE
|
||
|
--#LIFECYCLE
|
||
|
|
||
|
::= 2008
|
||
|
|
||
|
cpqSiHotPlugSlotBoardInserted TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiHotPlugSlotChassis,
|
||
|
cpqSiHotPlugSlotIndex }
|
||
|
DESCRIPTION
|
||
|
"Hot Plug Slot Board Inserted.
|
||
|
|
||
|
A Hot Plug Slot Board has been inserted into the specified
|
||
|
chassis and slot.
|
||
|
|
||
|
User Action: None."
|
||
|
|
||
|
--#TYPE "Hot Plug Slot Board Inserted (2009)"
|
||
|
--#SUMMARY "Hot plug slot board inserted into chassis %d, slot %d."
|
||
|
--#ARGUMENTS {2, 3}
|
||
|
--#SEVERITY INFORMATIONAL
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE OPERATIONAL
|
||
|
--#SIMPLE_SEVERITY OK
|
||
|
--#HWSTATUS_CATEGORY NONE
|
||
|
--#LIFECYCLE
|
||
|
|
||
|
::= 2009
|
||
|
|
||
|
cpqSiHotPlugSlotPowerUpFailed TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiHotPlugSlotChassis,
|
||
|
cpqSiHotPlugSlotIndex, cpqSiHotPlugSlotErrorStatus }
|
||
|
DESCRIPTION
|
||
|
"Hot Plug Slot Board Failed Power-Up.
|
||
|
|
||
|
A Hot Plug Slot Board has failed to power-up in the specified
|
||
|
chassis and slot.
|
||
|
|
||
|
User Action: Insure the board and all cables are installed
|
||
|
correctly and the board type and revision are the same as
|
||
|
the replaced board."
|
||
|
|
||
|
--#TYPE "Hot Plug Slot Board Failed (2010)"
|
||
|
--#SUMMARY "Hot plug slot board failed in chassis %d, slot %d, error %d."
|
||
|
--#ARGUMENTS {2, 3, 4}
|
||
|
--#SEVERITY CRITICAL
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE FAILED
|
||
|
--#SIMPLE_SEVERITY CRITICAL
|
||
|
--#HWSTATUS_CATEGORY NONE
|
||
|
--#ACTION "Ensure the board and all cables are installed correctly and that the board type and revision are the same as the replaced board."
|
||
|
|
||
|
::= 2010
|
||
|
|
||
|
cpqSiSysBatteryFailure TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
|
||
|
cpqSiSysBatterySerialNum }
|
||
|
DESCRIPTION
|
||
|
"The battery indicated by cpqSiSysBatteryIndex has failed
|
||
|
and must be replaced.
|
||
|
|
||
|
User Action: Contact your System Administrator or
|
||
|
Authorized Reseller to order a replacement battery.
|
||
|
Recycle your old battery. For proper disposal information,
|
||
|
refer to the documentation that came with your computer."
|
||
|
|
||
|
--#TYPE "Battery Failure (2011)"
|
||
|
--#SUMMARY "Battery %d has failed."
|
||
|
--#ARGUMENTS {2}
|
||
|
--#SEVERITY MAJOR
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE DEGRADED
|
||
|
--#SIMPLE_SEVERITY MAJOR
|
||
|
--#HWSTATUS_CATEGORY NONE
|
||
|
--#ACTION "Replace the failed battery."
|
||
|
|
||
|
::= 2011
|
||
|
|
||
|
cpqSiSysBatteryChargingDegraded TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
|
||
|
cpqSiSysBatterySerialNum }
|
||
|
DESCRIPTION
|
||
|
"Significant battery degradation has occurred with battery
|
||
|
indicated by cpqSiSysBatteryIndex. The battery can
|
||
|
no longer be fully recharged.
|
||
|
|
||
|
User Action: If using multiple batteries, run
|
||
|
the Power Conservation Utility to identify the
|
||
|
battery location. Contact your System Administrator
|
||
|
or Authorized Reseller to order a replacement
|
||
|
battery."
|
||
|
|
||
|
--#TYPE "Battery Charging Degradation (2012)"
|
||
|
--#SUMMARY "Battery %d has degraded charging capacity."
|
||
|
--#ARGUMENTS {2}
|
||
|
--#SEVERITY MAJOR
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE DEGRADED
|
||
|
--#SIMPLE_SEVERITY MAJOR
|
||
|
--#HWSTATUS_CATEGORY NONE
|
||
|
--#ACTION "Replace the failing battery."
|
||
|
::= 2012
|
||
|
|
||
|
|
||
|
cpqSiSysBatteryCalibrationError TRAP-TYPE
|
||
|
ENTERPRISE compaq
|
||
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
|
||
|
cpqSiSysBatterySerialNum }
|
||
|
DESCRIPTION
|
||
|
"Calibration is needed with battery
|
||
|
indicated by cpqSiSysBatteryIndex. The battery can
|
||
|
not correctly indicate capacity.
|
||
|
|
||
|
User Action: Run the Power Conservation Utility. Contact
|
||
|
your System Administrator or Authorized Reseller to
|
||
|
order a replacement battery."
|
||
|
|
||
|
--#TYPE "Battery Calibration Error (2013)"
|
||
|
--#SUMMARY "Battery %d has calibration error."
|
||
|
--#ARGUMENTS {2}
|
||
|
--#SEVERITY MAJOR
|
||
|
--#TIMEINDEX 99
|
||
|
--#STATE DEGRADED
|
||
|
--#SIMPLE_SEVERITY MAJOR
|
||
|
--#HWSTATUS_CATEGORY NONE
|
||
|
--#ACTION "Replace the failing battery."
|
||
|
::= 2013
|
||
|
|
||
|
END
|