mibs/MIBS/hpmsm/COLUBRIS-TOOLS-MIB.my

219 lines
7.1 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- ****************************************************************************
-- COLUBRIS-TOOLS-MIB definitions
--
-- Copyright (c) 2004, Colubris Networks, Inc.
-- All Rights Reserved.
--
-- Colubris Networks Tools MIB file.
--
-- ****************************************************************************
COLUBRIS-TOOLS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Unsigned32
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
InterfaceIndex
FROM IF-MIB
colubrisMgmtV2
FROM COLUBRIS-SMI
ColubrisNotificationEnable
FROM COLUBRIS-TC
;
colubrisToolsMIB MODULE-IDENTITY
LAST-UPDATED "200402200000Z"
ORGANIZATION "Colubris Networks, Inc."
CONTACT-INFO "Colubris Networks
Postal: 200 West Street Ste 300
Waltham, Massachusetts 02451-1121
UNITED STATES
Phone: +1 781 684 0001
Fax: +1 781 684 0009
E-mail: cn-snmp@colubris.com"
DESCRIPTION "Colubris Networks Tools MIB module."
::= { colubrisMgmtV2 12 }
-- colubrisToolsMIBObjects definition
colubrisToolsMIBObjects OBJECT IDENTIFIER ::= { colubrisToolsMIB 1 }
-- IP Trace groups
traceToolConfig OBJECT IDENTIFIER ::= { colubrisToolsMIBObjects 1 }
-- IP Trace configuration
traceInterface OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the interface to apply the trace to."
::= { traceToolConfig 1 }
traceCaptureDestination OBJECT-TYPE
SYNTAX INTEGER
{
local(1),
remote(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies if the traces shall be stored locally on the device
or remotely on a distant system.
'local': Stores the traces locally on the device.
'remote': Stores the traces in a remote file specified
by traceCaptureDestinationURL."
::= { traceToolConfig 2 }
traceCaptureDestinationURL OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the URL of the file that trace data will be sent to.
If a valid URL is not defined, the trace data cannot be sent
and will be discarded."
::= { traceToolConfig 3 }
traceTimeout OBJECT-TYPE
SYNTAX Unsigned32 (0..99999)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the amount of time the trace will capture data.
Once this limit is reached, the trace automatically stops."
DEFVAL { 600 }
::= { traceToolConfig 4 }
traceNumberOfPackets OBJECT-TYPE
SYNTAX Unsigned32 (0..99999)
UNITS "packets"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the maximum number of packets (IP datagrams) the
trace should capture. Once this limit is reached, the trace
automatically stops."
DEFVAL { 100 }
::= { traceToolConfig 5 }
tracePacketSize OBJECT-TYPE
SYNTAX Unsigned32 (68..4096)
UNITS "bytes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the maximum number of bytes to capture for each
packet. The remaining data is discarded."
DEFVAL { 128 }
::= { traceToolConfig 6 }
traceCaptureFilter OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the packet filter to use to capture data.
The filter expression has the same format and behavior
as the expression parameter used by the well-known
TCPDUMP command."
::= { traceToolConfig 7 }
traceCaptureStatus OBJECT-TYPE
SYNTAX INTEGER
{
stop(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IP Trace tool action trigger.
'stop': Stops the trace tool from functioning. If any
capture was previously started it will end up.
if no capture was started, 'stop' has no effect.
'start': Starts to capture the packets following the
critera specified in the management tool and
in this MIB."
DEFVAL { stop }
::= { traceToolConfig 8 }
traceNotificationEnabled OBJECT-TYPE
SYNTAX ColubrisNotificationEnable
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies if IP trace notifications are generated."
DEFVAL { disable }
::= { traceToolConfig 9 }
-- IP trace notifications
colubrisToolsMIBNotificationPrefix OBJECT IDENTIFIER ::= { colubrisToolsMIB 2 }
colubrisToolsMIBNotifications OBJECT IDENTIFIER ::= { colubrisToolsMIBNotificationPrefix 0 }
traceStatusNotification NOTIFICATION-TYPE
OBJECTS {
traceCaptureStatus
}
STATUS current
DESCRIPTION "Sent when the user triggers the IP Trace tool either by starting
a new trace or stopping an existing session."
--#SUMMARY "IP Trace status trap: %d"
--#ARGUMENTS { 0 }
--#SEVERITY INFORMATIONAL
--#CATEGORY "Colubris Networks Alarms"
::= { colubrisToolsMIBNotifications 1 }
-- conformance information
colubrisToolsMIBConformance OBJECT IDENTIFIER ::= { colubrisToolsMIB 3 }
colubrisToolsMIBCompliances OBJECT IDENTIFIER ::= { colubrisToolsMIBConformance 1 }
colubrisToolsMIBGroups OBJECT IDENTIFIER ::= { colubrisToolsMIBConformance 2 }
-- compliance statements
colubrisToolsMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "The compliance statement for entities which implement
the Colubris Networks Tools MIB."
MODULE MANDATORY-GROUPS
{
colubrisToolsMIBGroup,
colubrisToolsNotificationGroup
}
::= { colubrisToolsMIBCompliances 1 }
-- units of conformance
colubrisToolsMIBGroup OBJECT-GROUP
OBJECTS {
traceInterface,
traceCaptureDestination,
traceCaptureDestinationURL,
traceTimeout,
traceNumberOfPackets,
tracePacketSize,
traceCaptureFilter,
traceCaptureStatus,
traceNotificationEnabled
}
STATUS current
DESCRIPTION "A collection of objects providing the Tools MIB capability."
::= { colubrisToolsMIBGroups 1 }
colubrisToolsNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
traceStatusNotification
}
STATUS current
DESCRIPTION "A collection of supported notifications."
::= { colubrisToolsMIBGroups 2 }
END