139 lines
3.8 KiB
Plaintext
139 lines
3.8 KiB
Plaintext
|
-- MIB created 10/11/99 20:28:39, by
|
||
|
-- SMIC (the next generation) version 1.6.29, November 22, 1994.
|
||
|
|
||
|
IBM-FRAMERELAY-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
-- From file: "ibmframerelay.mi2"
|
||
|
-- Compile options "G A T M"
|
||
|
|
||
|
IMPORTS
|
||
|
Counter32, Integer32, IpAddress, Gauge32
|
||
|
FROM SNMPv2-SMI-v1
|
||
|
OBJECT-TYPE
|
||
|
FROM RFC-1212
|
||
|
DisplayString
|
||
|
FROM SNMPv2-TC-v1
|
||
|
enterprises
|
||
|
FROM RFC1155-SMI
|
||
|
ifIndex
|
||
|
FROM RFC1213-MIB
|
||
|
frCircuitIfIndex, frCircuitDlci
|
||
|
FROM RFC1315-MIB;
|
||
|
|
||
|
ibmIROCfrcircuit OBJECT IDENTIFIER ::= { enterprises ibm(2) ibmProd(6) ibmIROC(119) ibmIROCrouting(4) ibmIROCroutingfr(4) 5 }
|
||
|
-- MODULE-IDENTITY
|
||
|
-- LastUpdated
|
||
|
-- 9902171200Z
|
||
|
-- OrgName
|
||
|
-- IBM
|
||
|
-- ContactInfo
|
||
|
-- Randy Worzella
|
||
|
-- IBM Corporation
|
||
|
-- 800 Park Offices Drive
|
||
|
-- FBWA/664
|
||
|
-- P.O. Box 12195
|
||
|
-- Research Triangle Park, NC 27709, USA
|
||
|
-- Tel: 1 919 254 2202
|
||
|
-- E-mail: worzella@us.ibm.com
|
||
|
-- Descr
|
||
|
-- This MIB module contains enterprise specific definitions for
|
||
|
-- frame relay circuit management.
|
||
|
|
||
|
ibmframerelayPVCTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF IbmframerelayPVCEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A table providing PVC information and the capabiilty
|
||
|
to clear counters."
|
||
|
::= { ibmIROCfrcircuit 1 }
|
||
|
|
||
|
ibmframerelayPVCEntry OBJECT-TYPE
|
||
|
SYNTAX IbmframerelayPVCEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Entry identifying a particular permanent virtual circuit."
|
||
|
INDEX { frCircuitIfIndex, frCircuitDlci }
|
||
|
::= { ibmframerelayPVCTable 1 }
|
||
|
|
||
|
IbmframerelayPVCEntry ::= SEQUENCE {
|
||
|
ibmframerelayPVCCircName DisplayString,
|
||
|
ibmframerelayPVCTimesActive Counter32,
|
||
|
ibmframerelayPVCTimesInactive Counter32,
|
||
|
ibmframerelayPVCTimesCongested Counter32,
|
||
|
ibmframerelayPVCTxQueued Gauge32,
|
||
|
ibmframerelayPVCTxDropped Counter32,
|
||
|
ibmframerelayPVCClearAll Integer32
|
||
|
}
|
||
|
|
||
|
ibmframerelayPVCCircName OBJECT-TYPE
|
||
|
SYNTAX DisplayString
|
||
|
-- Rsyntax OCTET STRING(SIZE(0..255))
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The name string assigned to this PVC."
|
||
|
::= { ibmframerelayPVCEntry 1 }
|
||
|
|
||
|
ibmframerelayPVCTimesActive OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The times this PVC entered active state as
|
||
|
reported by frCircuitState."
|
||
|
::= { ibmframerelayPVCEntry 2 }
|
||
|
|
||
|
ibmframerelayPVCTimesInactive OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The times this PVC entered inactive state as
|
||
|
reported by frCircuitState."
|
||
|
::= { ibmframerelayPVCEntry 3 }
|
||
|
|
||
|
ibmframerelayPVCTimesCongested OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The times this PVC has become congested."
|
||
|
::= { ibmframerelayPVCEntry 4 }
|
||
|
|
||
|
ibmframerelayPVCTxQueued OBJECT-TYPE
|
||
|
SYNTAX Gauge32
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current number of frames queued for transmission
|
||
|
and waiting for space on the device transmit queue."
|
||
|
::= { ibmframerelayPVCEntry 5 }
|
||
|
|
||
|
ibmframerelayPVCTxDropped OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of frames discarded because they could
|
||
|
not be transmitted due to output queue overflow."
|
||
|
::= { ibmframerelayPVCEntry 6 }
|
||
|
|
||
|
ibmframerelayPVCClearAll OBJECT-TYPE
|
||
|
SYNTAX Integer32
|
||
|
ACCESS read-write
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"When SET to a value of 0, all the frame relay
|
||
|
counters for this PVC are cleared.
|
||
|
|
||
|
When READ, this object always returns a value of 0,
|
||
|
since this object is intended as a trigger, rather than
|
||
|
providing information."
|
||
|
::= { ibmframerelayPVCEntry 7 }
|
||
|
|
||
|
|
||
|
END
|
||
|
|