mibs/MIBS/junose/Juniper-FRAME-RELAY-MIB

1791 lines
64 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- *****************************************************************************
-- Juniper-FRAME-RELAY-MIB
--
-- Juniper Networks Enterprise MIB
-- Frame Relay MIB
--
-- Copyright (c) 1998, 1999 Redstone Communications, Inc.
-- Copyright (c) 2000 Unisphere Networks, Inc.
-- Copyright (c) 2002 Juniper Networks, Inc.
-- Copyright (c) 2004 Juniper Networks, Inc.
-- All Rights Reserved.
-- *****************************************************************************
Juniper-FRAME-RELAY-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32, TimeTicks
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus, TimeStamp
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
InterfaceIndex, InterfaceIndexOrZero
FROM IF-MIB
DLCI
FROM FRAME-RELAY-DTE-MIB
juniMibs
FROM Juniper-MIBs
JuniNextIfIndex
FROM Juniper-TC;
juniFrameRelayMIB MODULE-IDENTITY
LAST-UPDATED "200212131435Z" -- 13-Dec-02 09:35 AM EST
ORGANIZATION "Juniper Networks, Inc."
CONTACT-INFO
" Juniper Networks, Inc.
Postal: 10 Technology Park Drive
Westford MA 01886-3146
USA
Tel: +1 978 589 5800
Email: mib@Juniper.net"
DESCRIPTION
"The Frame Relay MIB for the Juniper Networks enterprise."
-- Revision History
REVISION "200212131435Z" -- 13-Dec-02 09:35 AM EST - JUNOSe 5.0
DESCRIPTION
"Replaced Unisphere names with Juniper names.
Added multi-link support."
REVISION "200009261730Z" -- 26-Sep-00 01:30 PM EDT - JUNOSe 3.0
DESCRIPTION
"Make it SMIv2 conformant."
REVISION "9906010000Z" -- 01-Jun-99 - JUNOSe 1.1
DESCRIPTION
"Add support for NNI behavior."
REVISION "9811130000Z" -- 13-Nov-98 - JUNOSe 1.0
DESCRIPTION
"Initial version of this MIB module."
::= { juniMibs 10 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Textual conventions
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
JuniFrMlFrBundleName ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"MLFR Bundle name. The bundle name is a characteristic of a MLFR frame
relay interface.
Represents textual information taken from the NVT ASCII graphics
character set (codes 32 through 126)."
REFERENCE
"RFC 854: NVT ASCII character set."
SYNTAX OCTET STRING (SIZE(0..32))
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Managed objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniFrObjects OBJECT IDENTIFIER ::= { juniFrameRelayMIB 1 }
--
-- This MIB contains managed objects for each of two interface
-- layers: Frame Relay interfaces, and Frame Relay subinterfaces.
-- For each of these layers, management objects are provided to
-- query for an available interface index, and to create/delete
-- interfaces of that type. Creating/deleting these interface
-- types using this MIB has the side effect of creating/deleting
-- corresponding entries in the Interface MIB ifTable/ifXTable,
-- and in the Juniper Enterprise Interface MIB juniIfTable.
--
juniFrIfLayer OBJECT IDENTIFIER ::= { juniFrObjects 1 }
juniFrSubIfLayer OBJECT IDENTIFIER ::= { juniFrObjects 2 }
juniFrMlFr OBJECT IDENTIFIER ::= { juniFrObjects 3 }
-- /////////////////////////////////////////////////////////////////////////////
--
-- Frame Relay Interface Layer
--
-- This layer is managed with the following elements:
--
-- o NextIfIndex (generator for Frame Relay IfIndex selection)
-- o DLCMI Table (creation/configuration/deletion of Frame Relay interfaces)
-- o DLCMI Statistics Table (Frame Relay interface statistics)
-- o Circuit Table (status of Frame Relay circuits)
--
-- /////////////////////////////////////////////////////////////////////////////
--
-- IfIndex selection for creating new Frame Relay interfaces
--
juniFrNextIfIndex OBJECT-TYPE
SYNTAX JuniNextIfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Coordinate ifIndex value allocation for entries in juniFrDlcmiTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously."
::= { juniFrIfLayer 1 }
--
-- The Frame Relay DLCMI Table
--
juniFrDlcmiTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniFrDlcmiEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Parameters for the Data Link Connection Management Interface for
the frame relay service on this interface.
This table represents a superset of functionality specified in the
FRAME-RELAY-DTE-MIB. In particular, it adds attributes that permit the
interface to operate as a network-side (DCE) interface."
REFERENCE
"American National Standard T1.617-1991, Annex D"
::= { juniFrIfLayer 2 }
juniFrDlcmiEntry OBJECT-TYPE
SYNTAX JuniFrDlcmiEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Parameters for a particular Data Link Connection Management
Interface.
Creating/deleting entries in this table causes corresponding entries for
be created/deleted in ifTable/ifXTable/juniIfTable, and
juniFrDlcmiStatsTable.
Creating/deleting user-side (DTE) entries in this table also causes
coresponding entries to be created/deleted in
FRAME-RELAY-DTE-MIB.frDlcmiTable.
The organization and definitions of objects in this table are
intentionally aligned closely to those in FRAME-RELAY-DTE-MIB."
INDEX { juniFrDlcmiIfIndex }
::= { juniFrDlcmiTable 1 }
JuniFrDlcmiEntry ::= SEQUENCE {
juniFrDlcmiIfIndex InterfaceIndex,
juniFrDlcmiState INTEGER,
juniFrDlcmiAddress INTEGER,
juniFrDlcmiAddressLen INTEGER,
juniFrDlcmiPollingInterval Integer32,
juniFrDlcmiFullEnquiryInterval Integer32,
juniFrDlcmiErrorThreshold Integer32,
juniFrDlcmiMonitoredEvents Integer32,
juniFrDlcmiMaxSupportedVCs DLCI,
juniFrDlcmiMulticast INTEGER,
juniFrDlcmiStatus INTEGER,
juniFrDlcmiRowStatus RowStatus,
juniFrDlcmiLowerIfIndex InterfaceIndexOrZero,
juniFrDlcmiRole INTEGER,
juniFrDlcmiDcePollingInterval Integer32,
juniFrDlcmiDceErrorThreshold Integer32,
juniFrDlcmiDceMonitoredEvents Integer32,
juniFrDlcmiMultilinkFrBundleName JuniFrMlFrBundleName }
juniFrDlcmiIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex value of the corresponding ifEntry."
::= { juniFrDlcmiEntry 1 }
juniFrDlcmiState OBJECT-TYPE
SYNTAX INTEGER {
noLmiConfigured(1),
lmiRev1(2),
ansiT1617D(3), -- ANSI T1.617 Annex D
ansiT1617B(4), -- ANSI T1.617 Annex B
itut933A(5), -- ITU-T Q933 Annex A
ansiT1617D1994(6) } -- ANSI T1.617a-1994 Annex D
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable states which Data Link Connection Management scheme is
active (and by implication, what DLCI it uses) on the Frame Relay
interface."
REFERENCE
"American National Standard T1.617-1991, American National Standard
T1.617a-1994, ITU-T Recommendation Q.933 (03/93)."
::= { juniFrDlcmiEntry 2 }
juniFrDlcmiAddress OBJECT-TYPE
SYNTAX INTEGER {
q921(1), -- 13 bit DLCI
q922March90(2), -- 11 bit DLCI
q922November90(3), -- 10 bit DLCI
q922(4) } -- Final Standard
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable states which address format is in use on the Frame Relay
interface."
DEFVAL { q922 }
::= { juniFrDlcmiEntry 3 }
juniFrDlcmiAddressLen OBJECT-TYPE
SYNTAX INTEGER {
twoOctets(2),
threeOctets(3),
fourOctets(4) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable states the address length in octets. In the case of Q922
format, the length indicates the entire length of the address including
the control portion."
DEFVAL { twoOctets }
::= { juniFrDlcmiEntry 4 }
juniFrDlcmiPollingInterval OBJECT-TYPE
SYNTAX Integer32 (5..30)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the number of seconds between successive status enquiry
messages sent by the DTE.
Pertains to DTE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DTE or NNI."
REFERENCE
"American National Standard T1.617-1991, Section D.7 Timer T391."
DEFVAL { 10 }
::= { juniFrDlcmiEntry 5 }
juniFrDlcmiFullEnquiryInterval OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of status enquiry intervals that pass before issuance of a full
status enquiry message.
Pertains to DTE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DTE or NNI."
REFERENCE
"American National Standard T1.617-1991, Section D.7 Counter N391."
DEFVAL { 6 }
::= { juniFrDlcmiEntry 6 }
juniFrDlcmiErrorThreshold OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The minimum number of errors that must be observed within the number of
events specified by juniFrDlcmiMonitoredEvents, to declare the interface
down.
'error' is lack of receipt of a Status, in response to an issued Status
Enquiry, within the Polling Interval (T391).
Pertains to DTE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DTE or NNI."
REFERENCE
"American National Standard T1.617-1991, Section D.5.1 Counter N392."
DEFVAL { 3 }
::= { juniFrDlcmiEntry 7 }
juniFrDlcmiMonitoredEvents OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of status polling intervals over which the error threshold
is counted. For example, if within 'MonitoredEvents' number of events
the station receives 'ErrorThreshold' number of errors, the interface is
marked as down.
'status polling interval' is specified by juniFrDlcmiPollingInterval.
Pertains to DTE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DTE or NNI."
REFERENCE
"American National Standard T1.617-1991, Section D.5.2 Counter N393."
DEFVAL { 4 }
::= { juniFrDlcmiEntry 8 }
juniFrDlcmiMaxSupportedVCs OBJECT-TYPE
SYNTAX DLCI
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of Virtual Circuits allowed for this interface.
Usually dictated by the Frame Relay network.
In response to a SET, if a value less than zero or higher than the
agent's maximal capability is configured, the agent should respond
badValue."
::= { juniFrDlcmiEntry 9 }
juniFrDlcmiMulticast OBJECT-TYPE
SYNTAX INTEGER {
nonBroadcast(1),
broadcast(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This indicates whether the Frame Relay interface is using a multicast
service."
DEFVAL { nonBroadcast }
::= { juniFrDlcmiEntry 10 }
juniFrDlcmiStatus OBJECT-TYPE
SYNTAX INTEGER {
running(1), -- init complete, system running
fault(2), -- error threshold exceeded
initializing(3) } -- system start up
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates the status of the Frame Relay interface as determined by
the performance of the DLCMI. If no DLCMI is running, the Frame Relay
interface will stay in the running state indefinitely."
::= { juniFrDlcmiEntry 11 }
juniFrDlcmiRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrDlcmiRowStatus
juniFrDlcmiState
juniFrDlcmiMaxSupportedVCs
juniFrDlcmiLowerIfIndex
juniFrDlcmiRole
juniFrDlcmiMultilinkFrBundleName (Only for multilink frame relay)
In addition, when creating an entry the following conditions must hold:
A value for juniFrDlcmiIndex must have been determined previously,
by reading juniFrNextIfIndex.
The interface identified by juniFrDlcmiLowerIfIndex must exist, and
must be an interface type that permits layering of Frame Relay above
it.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table. If
juniFrDlcmiRole is dte(0), a corresponding entry is created/deleted in
frDlcmiTable."
::= { juniFrDlcmiEntry 12 }
juniFrDlcmiLowerIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex of an interface over which this Frame Relay interface is to
be layered. A value of zero indicates no layering. An implementation
may choose to require that a nonzero value be configured at entry
creation. In case of multilink frame relay support, it will be
multilink frame relay interface's ifIndex."
::= { juniFrDlcmiEntry 13 }
juniFrDlcmiRole OBJECT-TYPE
SYNTAX INTEGER {
dte(0),
dce(1),
nni(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the role this interface assumes with respect to the remote
end.
When acting as a DTE, the following objects are not relevant:
juniFrDlcmiDcePollingInterval
juniFrDlcmiDceErrorThreshold
juniFrDlcmiDceMonitoredEvents
When acting as a DCE, the following objects are not relevant:
juniFrDlcmiPollingInterval
juniFrDlcmiFullEnquiryInterval
juniFrDlcmiErrorThreshold
juniFrDlcmiMonitoredEvents "
::= { juniFrDlcmiEntry 14 }
juniFrDlcmiDcePollingInterval OBJECT-TYPE
SYNTAX Integer32 (5..30)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of seconds within which a DCE expects to receive a Status
Enquiry from the DTE.
This value corresponds to the T392 timer.
Pertains to DCE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DCE or NNI."
DEFVAL { 15 }
::= { juniFrDlcmiEntry 15 }
juniFrDlcmiDceErrorThreshold OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The minimum number of errors that must be observed within the number of
events specified by juniFrDlcmiDceMonitoredEvents, to declare the
interface down.
'error' is lack of receipt of a Status Enquiry within the interval
specified by juniFrDlcmiDcePollingInterval (T392).
Pertains to DCE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DCE or NNI."
DEFVAL { 2 }
::= { juniFrDlcmiEntry 16 }
juniFrDlcmiDceMonitoredEvents OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of DCE polling intervals over which accumulated errors are
counted against the threshold specified in juniFrDlcmiDceErrorThreshold.
If, within this number of events, the number of errors equals or exceeds
the threshold, the interface is declared down.
The 'DCE polling interval' is specified by
juniFrDlcmiDcePollingInterval.
Pertains to DCE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DCE or NNI."
DEFVAL { 2 }
::= { juniFrDlcmiEntry 17 }
juniFrDlcmiMultilinkFrBundleName OBJECT-TYPE
SYNTAX JuniFrMlFrBundleName
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This represents multilink frame relay bundle name. This object must be
configured to associate the bundle name to the frame relay major
interface to support the multilink frame relay encapsulation. For
non-multilink frame relay, bundle name configuration is not valid and
will be ignored."
DEFVAL { "" }
::= { juniFrDlcmiEntry 18 }
--
-- The Frame Relay Data Link Connection Management Interface (DLCMI) Statistics
-- Table
--
juniFrDlcmiStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniFrDlcmiStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for the Data Link Connection Management Interface for
the frame relay service on this interface."
::= { juniFrIfLayer 3 }
juniFrDlcmiStatsEntry OBJECT-TYPE
SYNTAX JuniFrDlcmiStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a particular Data Link Connection Management
Interface.
Statistics are not relevant while the juniFrDlcmiState has the value
'noLmiConfigured'.
The DTE statistics are relevant when the corresponding juniFrDlcmiRole
is DTE.
The DTE statistics are relevant when the corresponding juniFrDlcmiRole
is DCE."
INDEX { juniFrDlcmiIfIndex }
::= { juniFrDlcmiStatsTable 1 }
JuniFrDlcmiStatsEntry ::= SEQUENCE {
juniFrDlcmiStatsDteEnquiries Counter32,
juniFrDlcmiStatsDteFullEnquiries Counter32,
juniFrDlcmiStatsDteEnquiryResponses Counter32,
juniFrDlcmiStatsDteFullEnquiryResponses Counter32,
juniFrDlcmiStatsDteAsyncUpdates Counter32,
juniFrDlcmiStatsDteUnknownRxMessages Counter32,
juniFrDlcmiStatsDteLossOfSequences Counter32,
juniFrDlcmiStatsDteNoResponseTimeouts Counter32,
juniFrDlcmiStatsDceEnquiries Counter32,
juniFrDlcmiStatsDceFullEnquiries Counter32,
juniFrDlcmiStatsDceEnquiryResponses Counter32,
juniFrDlcmiStatsDceFullEnquiryResponses Counter32,
juniFrDlcmiStatsDceAsyncUpdates Counter32,
juniFrDlcmiStatsDceUnknownRxMessages Counter32,
juniFrDlcmiStatsDceLossOfSequences Counter32,
juniFrDlcmiStatsDceNoResponseTimeouts Counter32,
juniFrDlcmiStatsDiscontinuityTime TimeTicks }
juniFrDlcmiStatsDteEnquiries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Status Enquiries sent (as DTE)."
::= { juniFrDlcmiStatsEntry 1 }
juniFrDlcmiStatsDteFullEnquiries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Full Enquiries sent (as DTE)."
::= { juniFrDlcmiStatsEntry 2 }
juniFrDlcmiStatsDteEnquiryResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Status Enquiry responses received (as DTE)."
::= { juniFrDlcmiStatsEntry 3 }
juniFrDlcmiStatsDteFullEnquiryResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Full Enquiry responses received (as DTE)."
::= { juniFrDlcmiStatsEntry 4 }
juniFrDlcmiStatsDteAsyncUpdates OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Asynchronous Updates received (as DTE)."
::= { juniFrDlcmiStatsEntry 5 }
juniFrDlcmiStatsDteUnknownRxMessages OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of unknown messages received (as DTE)."
::= { juniFrDlcmiStatsEntry 6 }
juniFrDlcmiStatsDteLossOfSequences OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times a discontinuity in sequence numbering of received
messages was detected (as DTE)."
::= { juniFrDlcmiStatsEntry 7 }
juniFrDlcmiStatsDteNoResponseTimeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of timer expirations awaiting a Status message (as DTE)."
::= { juniFrDlcmiStatsEntry 8 }
juniFrDlcmiStatsDceEnquiries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Status Enquiries received (as DCE.)"
::= { juniFrDlcmiStatsEntry 9 }
juniFrDlcmiStatsDceFullEnquiries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Full Enquiries received (as DCE)."
::= { juniFrDlcmiStatsEntry 10 }
juniFrDlcmiStatsDceEnquiryResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Status Enquiry responses sent (as DCE)."
::= { juniFrDlcmiStatsEntry 11 }
juniFrDlcmiStatsDceFullEnquiryResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Full Enquiry responses sent (as DCE)."
::= { juniFrDlcmiStatsEntry 12 }
juniFrDlcmiStatsDceAsyncUpdates OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Asynchronous Updates sent (as DCE)."
::= { juniFrDlcmiStatsEntry 13 }
juniFrDlcmiStatsDceUnknownRxMessages OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of unknown messages received (as DCE)."
::= { juniFrDlcmiStatsEntry 14 }
juniFrDlcmiStatsDceLossOfSequences OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times a discontinuity in sequence numbering of received
messages was detected (as DCE)."
::= { juniFrDlcmiStatsEntry 15 }
juniFrDlcmiStatsDceNoResponseTimeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of timer expirations awaiting a Status Enquiry (as DCE)."
::= { juniFrDlcmiStatsEntry 16 }
juniFrDlcmiStatsDiscontinuityTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of sysUpTime at the most recent event that caused a discontinuity
in the monotonic operation of any of the counters in this entry. Such
disruption might be caused by:
Hardware insertion/removal.
Reconfiguration of juniFrDlcmiState.
Reconfiguration of juniFrDlcmiRole.
Conclusions can be drawn from successive polls of an entry's counters
only if the value of this object, simultaneously retrieved in those
polls, remains unchanged."
::= { juniFrDlcmiStatsEntry 17 }
--
-- Frame Relay Circuit Table
--
juniFrCircuitTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniFrCircuitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about specific Data Link Connections
(DLC) or virtual circuits.
This table mirrors the structure of FRAME-RELAY-DTE-MIB.frCircuitTable,
for the purpose of enumerating circuits on both DTE and DCE Frame Relay
interfaces."
::= { juniFrIfLayer 4 }
juniFrCircuitEntry OBJECT-TYPE
SYNTAX JuniFrCircuitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The information regarding a single Data Link Connection.
Discontinuities in the counters contained in this table are indicated by
the value in juniFrCircuitCreationTime."
INDEX { juniFrCircuitIfIndex,
juniFrCircuitDlci }
::= { juniFrCircuitTable 1 }
JuniFrCircuitEntry ::= SEQUENCE {
juniFrCircuitIfIndex InterfaceIndex,
juniFrCircuitDlci DLCI,
juniFrCircuitState INTEGER,
juniFrCircuitReceivedFECNs Counter32,
juniFrCircuitReceivedBECNs Counter32,
juniFrCircuitSentFrames Counter32,
juniFrCircuitSentOctets Counter32,
juniFrCircuitReceivedFrames Counter32,
juniFrCircuitReceivedOctets Counter32,
juniFrCircuitCreationTime TimeStamp,
juniFrCircuitLastTimeChange TimeStamp,
juniFrCircuitCommittedBurst Integer32,
juniFrCircuitExcessBurst Integer32,
juniFrCircuitThroughput Integer32,
juniFrCircuitMulticast INTEGER,
juniFrCircuitType INTEGER,
juniFrCircuitDiscards Counter32,
juniFrCircuitReceivedDEs Counter32,
juniFrCircuitSentDEs Counter32,
juniFrCircuitLogicalIfIndex InterfaceIndex,
juniFrCircuitRowStatus RowStatus,
juniFrCircuitSentFECNs Counter32,
juniFrCircuitSentBECNs Counter32 }
juniFrCircuitIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex Value of the ifEntry this virtual circuit is layered onto."
::= { juniFrCircuitEntry 1 }
juniFrCircuitDlci OBJECT-TYPE
SYNTAX DLCI
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Data Link Connection Identifier for this virtual circuit."
REFERENCE
"American National Standard T1.618-1991, Section 3.3.6"
::= { juniFrCircuitEntry 2 }
juniFrCircuitState OBJECT-TYPE
SYNTAX INTEGER {
invalid(1),
active(2),
inactive(3) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the particular virtual circuit is operational. In
the absence of a Data Link Connection Management Interface, virtual
circuit entries (rows) may be created by setting virtual circuit state
to 'active', or deleted by changing Circuit state to 'invalid'.
Whether or not the row actually disappears is left to the
implementation, so this object may actually read as 'invalid' for some
arbitrary length of time. It is also legal to set the state of a
virtual circuit to 'inactive' to temporarily disable a given circuit.
The use of 'invalid' is deprecated in this SNMP Version 2 MIB, in favor
of juniFrCircuitRowStatus."
DEFVAL { active }
::= { juniFrCircuitEntry 3 }
juniFrCircuitReceivedFECNs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames received from the network indicating forward
congestion since the virtual circuit was created. This occurs when the
remote DTE sets the FECN flag, or when a switch in the network enqueues
the frame to a trunk whose transmission queue is congested."
REFERENCE
"American National Standard T1.618-1991, Section 3.3.3"
::= { juniFrCircuitEntry 4 }
juniFrCircuitReceivedBECNs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames received from the network indicating backward
congestion since the virtual circuit was created. This occurs when the
remote DTE sets the BECN flag, or when a switch in the network receives
the frame from a trunk whose transmission queue is congested."
REFERENCE
"American National Standard T1.618-1991, Section 3.3.4"
::= { juniFrCircuitEntry 5 }
juniFrCircuitSentFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent from this virtual circuit since it was
created."
::= { juniFrCircuitEntry 6 }
juniFrCircuitSentOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets sent from this virtual circuit since it was
created. Octets counted are the full frame relay header and the
payload, but do not include the flag characters or CRC."
::= { juniFrCircuitEntry 7 }
juniFrCircuitReceivedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames received over this virtual circuit since it was
created."
::= { juniFrCircuitEntry 8 }
juniFrCircuitReceivedOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of octets received over this virtual circuit since it was
created. Octets counted include the full frame relay header, but do not
include the flag characters or the CRC."
::= { juniFrCircuitEntry 9 }
juniFrCircuitCreationTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the virtual circuit was created, whether by
the Data Link Connection Management Interface or by a SetRequest."
::= { juniFrCircuitEntry 10 }
juniFrCircuitLastTimeChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when last there was a change in the virtual
circuit state"
::= { juniFrCircuitEntry 11 }
juniFrCircuitCommittedBurst OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the maximum amount of data, in bits, that the
network agrees to transfer under normal conditions, during the
measurement interval. A value of zero (the default) indicates no
commitment."
REFERENCE
"American National Standard T1.617-1991, Section 6.5.19"
DEFVAL { 0 }
::= { juniFrCircuitEntry 12 }
juniFrCircuitExcessBurst OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the maximum amount of uncommitted data bits
that the network will attempt to deliver over the measurement interval.
By default, if not configured when creating the entry, the Excess
Information Burst Size is set to the value of ifSpeed."
REFERENCE
"American National Standard T1.617-1991, Section 6.5.19"
::= { juniFrCircuitEntry 13 }
juniFrCircuitThroughput OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Throughput is the average number of 'Frame Relay Information Field'
bits transferred per second across a user network interface in one
direction, measured over the measurement interval.
If the configured committed burst rate and throughput are both non-zero,
the measurement interval, T, is
T = juniFrCircuitCommittedBurst / juniFrCircuitThroughput.
If the configured committed burst rate and throughput are both zero, the
measurement interval, T, is
T = juniFrCircuitExcessBurst / ifSpeed
A value of zero (the default) for throughput indicates no commitment."
REFERENCE
"American National Standard T1.617-1991, Section 6.5.19"
DEFVAL { 0 }
::= { juniFrCircuitEntry 14 }
juniFrCircuitMulticast OBJECT-TYPE
SYNTAX INTEGER {
unicast(1),
oneWay(2),
twoWay(3),
nWay(4) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This indicates whether this VC is used as a unicast VC (i.e. not
multicast) or the type of multicast service subscribed to."
REFERENCE
"Frame Relay PVC Multicast Service and Protocol Description
Implementation: FRF.7 Frame Relay Forum Technical Committe October 21,
1994"
DEFVAL { unicast }
::= { juniFrCircuitEntry 15 }
juniFrCircuitType OBJECT-TYPE
SYNTAX INTEGER {
static(1),
dynamic(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indication of whether the VC was manually created (static), or
dynamically created (dynamic) via the data link control management
interface."
::= { juniFrCircuitEntry 16 }
juniFrCircuitDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of inbound frames dropped because of format errors, or
because the VC is inactive."
::= { juniFrCircuitEntry 17 }
juniFrCircuitReceivedDEs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames received from the network indicating that they were
eligible for discard since the virtual circuit was created. This occurs
when the remote DTE sets the DE flag, or when in remote DTE's switch
detects that the frame was received as Excess Burst data."
REFERENCE
"American National Standard T1.618-1991, Section 3.3.4"
::= { juniFrCircuitEntry 18 }
juniFrCircuitSentDEs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames sent to the network indicating that they were eligible
for discard since the virtual circuit was created. This occurs when the
local DTE sets the DE flag, indicating that during Network congestion
situations those frames should be discarded in preference of other
frames sent without the DE bit set."
REFERENCE
"American National Standard T1.618-1991, Section 3.3.4"
::= { juniFrCircuitEntry 19 }
juniFrCircuitLogicalIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Normally the same value as frDlcmiIfIndex, but different when an
implementation associates a virtual ifEntry with a DLC or set of DLCs in
order to associate higher layer objects such as the ipAddrEntry with a
subset of the virtual circuits on a Frame Relay interface. The type of
such ifEntries is defined by the higher layer object; for example, if
PPP/Frame Relay is implemented, the ifType of this ifEntry would be PPP.
If it is not so defined, as would be the case with an ipAddrEntry, it
should be of type Other."
::= { juniFrCircuitEntry 20 }
juniFrCircuitRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or modify or destroy an
existing row in the manner described in the definition of the RowStatus
textual convention. Writable objects in the table may be written in any
RowStatus state."
::= { juniFrCircuitEntry 21 }
juniFrCircuitSentFECNs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames sent to the network indicating forward congestion
since the virtual circuit was created. This occurs when the remote DTE
sets the FECN flag, or when a switch in the network enqueues the frame
to a trunk whose transmission queue is congested."
REFERENCE
"American National Standard T1.618-1991, Section 3.3.3"
::= { juniFrCircuitEntry 22 }
juniFrCircuitSentBECNs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames sent to the network indicating backward congestion
since the virtual circuit was created. This occurs when the remote DTE
sets the BECN flag, or when a switch in the network receives the frame
from a trunk whose transmission queue is congested."
REFERENCE
"American National Standard T1.618-1991, Section 3.3.4"
::= { juniFrCircuitEntry 23 }
-- /////////////////////////////////////////////////////////////////////////////
--
-- Frame Relay Subinterface Layer
--
-- This layer is managed with the following elements:
--
-- o NextIfIndex (generator for Frame Relay subinterface IfIndex selection)
-- o SubIf Table (creation/configuration/deletion of Frame Relay subinterfaces)
-- o SubIf Circuit Table (creation/deletion of circuits associated with
-- subinterfaces)
--
-- /////////////////////////////////////////////////////////////////////////////
--
-- IfIndex selection for creating new Frame Relay Subinterfaces
--
juniFrSubIfNextIfIndex OBJECT-TYPE
SYNTAX JuniNextIfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Coordinate ifIndex value allocation for entries in juniFrSubIfTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously."
::= { juniFrSubIfLayer 1 }
--
-- The Frame Relay Subinterface Table
--
juniFrSubIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniFrSubIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for Frame Relay Subinterfaces present in
the system."
::= { juniFrSubIfLayer 2 }
juniFrSubIfEntry OBJECT-TYPE
SYNTAX JuniFrSubIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of a Frame Relay Subinterface.
Creating/deleting entries in this table causes corresponding entries for
be created /deleted in ifTable/ifXTable/juniIfTable."
INDEX { juniFrSubIfIndex }
::= { juniFrSubIfTable 1 }
JuniFrSubIfEntry ::= SEQUENCE {
juniFrSubIfIndex InterfaceIndex,
juniFrSubIfRowStatus RowStatus,
juniFrSubIfLowerIfIndex InterfaceIndexOrZero,
juniFrSubIfId Integer32 }
juniFrSubIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the Frame Relay Subinterface. When creating entries in
this table, suitable values for this object are determined by reading
juniFrSubNextIfIndex."
::= { juniFrSubIfEntry 1 }
juniFrSubIfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrSubIfRowStatus
juniFrSubIfLowerIfIndex
In addition, when creating an entry the following conditions must hold:
A value for juniFrSubIfIndex must have been determined previously,
by reading juniFrSubIfNextIfIndex.
The interface identified by juniFrSubIfLowerIfIndex must exist, and
must be a Frame Relay interface.
A positive value configured for juniFrSubIfId must not already be
assigned to another subinterface layered onto the same underlying
Frame Relay interface.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table."
::= { juniFrSubIfEntry 2 }
juniFrSubIfLowerIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex of a Frame Relay interface over which this Frame Relay
Subinterface is to be layered. A value of zero indicates no layering.
An implementation may choose to require that a nonzero value be
configured at entry creation."
::= { juniFrSubIfEntry 3 }
juniFrSubIfId OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An integer identifier for the Frame Relay subinterface, used in
conjunction with the command-line interface. It is provided here for
cross-reference purposes only.
The value must be unique among subinterfaces configured on the same
underlying Frame Relay interface.
If this object is not configured, or is configured with a value of -1, a
nonzero value will be allocated internally and can be retrieved from
this object after table entry creation has succeeded.
A value of zero for this object is reserved for future use."
DEFVAL { -1 }
::= { juniFrSubIfEntry 4 }
--
-- The Frame Relay Subinterface Circuit Table
--
juniFrSubIfCktTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniFrSubIfCktEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for Frame Relay circuits configured on
Frame Relay Subinterfaces present in the system.
An implementation may constrain the number of circuits permitted to be
configured per Frame Relay Subinterface; in particular, an
implementation may restrict each Frame Relay Subinterface to have a
single circuit.
Attributes in this entry can only be configured at entry creation, and
remain fixed for the lifetime of the entry."
::= { juniFrSubIfLayer 3 }
juniFrSubIfCktEntry OBJECT-TYPE
SYNTAX JuniFrSubIfCktEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of a Frame Relay Subinterface
circuit."
INDEX { juniFrSubIfIndex,
juniFrSubIfCktDlci }
::= { juniFrSubIfCktTable 1 }
JuniFrSubIfCktEntry ::= SEQUENCE {
juniFrSubIfCktDlci DLCI,
juniFrSubIfCktRowStatus RowStatus }
juniFrSubIfCktDlci OBJECT-TYPE
SYNTAX DLCI
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DLCI of the Frame Relay circuit used by this subinterface."
::= { juniFrSubIfCktEntry 1 }
juniFrSubIfCktRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrSubIfCktRowStatus "
::= { juniFrSubIfCktEntry 2 }
-- /////////////////////////////////////////////////////////////////////////////
--
-- Multi-Link Frame Relay (MLFR)
--
-- This section defines objects used to manage the MLFR.
--
-- /////////////////////////////////////////////////////////////////////////////
--
-- The MLFR BundleTable
--
juniFrMlFrBundleTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniFrMlFrBundleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for MLFR bundles present in the system."
::= { juniFrMlFr 1 }
juniFrMlFrBundleEntry OBJECT-TYPE
SYNTAX JuniFrMlFrBundleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of a Multilink bundle."
INDEX { juniFrMlFrBundleName }
::= { juniFrMlFrBundleTable 1 }
JuniFrMlFrBundleEntry ::= SEQUENCE {
juniFrMlFrBundleName JuniFrMlFrBundleName,
juniFrMlFrBundleRowStatus RowStatus }
juniFrMlFrBundleName OBJECT-TYPE
SYNTAX JuniFrMlFrBundleName
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The administrative name of the multilink bundle associated with this
Frame Relay major interface."
::= { juniFrMlFrBundleEntry 1 }
juniFrMlFrBundleRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The rowStatus for this entry. The following sets are supported:
createAndGo(4),
destroy(6)
The following values can be read from this object:
active(1) "
::= { juniFrMlFrBundleEntry 2 }
--
-- IfIndex selection for creating new MLFR Link interfaces
-- in juniFrMlFrLinkConfigTable.
--
juniFrMlFrNextLinkIfIndex OBJECT-TYPE
SYNTAX JuniNextIfIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Coordinate ifIndex value allocation for entries in
juniFrMlFrLinkConfigTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously."
::= { juniFrMlFr 2 }
--
-- The MLFR Link Configuration Table
--
juniFrMlFrLinkConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniFrMlFrLinkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for FR link interfaces present in the
system to be added to the multilink bundles."
::= { juniFrMlFr 3 }
juniFrMlFrLinkConfigEntry OBJECT-TYPE
SYNTAX JuniFrMlFrLinkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of FR link interface.
Creating/deleting entries in this table causes corresponding entries for
be created/deleted in ifTable/ifXTable/juniIfTable."
INDEX { juniFrMlFrLinkConfigIfIndex }
::= { juniFrMlFrLinkConfigTable 1 }
JuniFrMlFrLinkConfigEntry ::= SEQUENCE {
juniFrMlFrLinkConfigIfIndex InterfaceIndex,
juniFrMlFrLinkConfigLowerIfIndex InterfaceIndexOrZero,
juniFrMlFrLinkConfigRowStatus RowStatus }
juniFrMlFrLinkConfigIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the FR link interface. When creating entries in this
table, suitable values for this object are determined by reading
juniFrMlFrNextLinkIfIndex."
::= { juniFrMlFrLinkConfigEntry 1 }
juniFrMlFrLinkConfigLowerIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex of an interface over which this FR link interface is to be
layered. A value of zero indicates no layering. An implementation may
choose to require that a non-zero value be configured at entry
creation."
::= { juniFrMlFrLinkConfigEntry 2 }
juniFrMlFrLinkConfigRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrMlFrLinkConfigRowStatus
juniFrMlFrLinkConfigLowerIfIndex
In addition, when creating an entry the following conditions must hold:
A value for juniFrMlFrLinkConfigIfIndex must have been determined
previously, by reading juniFrMlFrNextIfIndex.
The interface identified by juniFrMlFrLinkConfigLowerIfIndex must
exist.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table."
::= { juniFrMlFrLinkConfigEntry 3 }
--
-- The MLFR Major interface Configuration Table
--
juniFrMlFrMajorConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniFrMlFrMajorConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for FR major interfaces present in the
system which are associated with multilink bundles."
::= { juniFrMlFr 4 }
juniFrMlFrMajorConfigEntry OBJECT-TYPE
SYNTAX JuniFrMlFrMajorConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the characteristics of FR major interface which
have association with the MLFR bundles. Creating/deleting entries in
this table causes corresponding entries for be created/deleted in
ifTable/ifXTable/juniIfTable."
INDEX { juniFrMlFrMajorConfigIfIndex }
::= { juniFrMlFrMajorConfigTable 1 }
JuniFrMlFrMajorConfigEntry ::= SEQUENCE {
juniFrMlFrMajorConfigIfIndex InterfaceIndex,
juniFrMlFrMajorConfigLowerIfIndex InterfaceIndex,
juniFrMlFrMajorBundleName JuniFrMlFrBundleName,
juniFrMlFrMajorRowStatus RowStatus }
juniFrMlFrMajorConfigIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the FR Major interface. When creating entries in this
table, suitable values for this object are determined by reading already
created FR Major interface values.
Each multilink bundle will be associated with one FR major interface.
This association will be done at the creation of FR major interface
(juniFrDlcmiTable) specifying its lower interfce binding as FR link
ifIndex(juniFrMlFrLinkConfigTable) and the multilink bundle name."
::= { juniFrMlFrMajorConfigEntry 1 }
juniFrMlFrMajorConfigLowerIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex of a FR link interface over which this FR Major interface
is to be layered. On sets, the value of this object must equal on of
the previously created FR link interfaces created in the
juniFrMlFrLinkConfigTable. On gets, the value of this object is the
lexicographically least FR link interface in a potential bundle of FR
link interfaces."
::= { juniFrMlFrMajorConfigEntry 2 }
juniFrMlFrMajorBundleName OBJECT-TYPE
SYNTAX JuniFrMlFrBundleName
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The MLFR bundle name administratively assigned."
::= { juniFrMlFrMajorConfigEntry 3 }
juniFrMlFrMajorRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrMlFrMajorConfigLowerIfIndex
juniFrMlFrMajorBundleName
juniFrMlFrMajorConfigRowStatus
In addition, when creating an entry the following conditions must hold:
The interface identified by juniFrMlFrMajorConfigIndex must exist by
a creation request to the juniFrDlcmiTable.
The interface identified by juniFrMlFrMajorConfigLowerIfIndex must
exist by a creation request to the juniFrMlFrLinkConfigTable.
The bundleName specified in juniFrMlFrMajorBundleName must have
been created first in the juniFrMlFrBundleTable.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table. "
::= { juniFrMlFrMajorConfigEntry 4 }
--
-- The MLFR Link Bind Table
--
juniFrMlFrLinkBindTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniFrMlFrLinkBindEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains entries for FR Link interfaces to FR major
interfaces bindings associated with multilink bundles."
::= { juniFrMlFr 5 }
juniFrMlFrLinkBindEntry OBJECT-TYPE
SYNTAX JuniFrMlFrLinkBindEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describes the FR link interface to FR major interface
bindingsi associated with multilink bundles."
INDEX { juniFrMlFrBindMajorIfIndex,
juniFrMlFrBindLinkIfIndex }
::= { juniFrMlFrLinkBindTable 1 }
JuniFrMlFrLinkBindEntry ::= SEQUENCE {
juniFrMlFrBindMajorIfIndex InterfaceIndex,
juniFrMlFrBindLinkIfIndex InterfaceIndex,
juniFrMlFrBindRowStatus RowStatus }
juniFrMlFrBindMajorIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of the FR major interface associated with multilink."
::= { juniFrMlFrLinkBindEntry 1 }
juniFrMlFrBindLinkIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ifIndex of a FR link interface bound by the FR major interface
defined by juniFrMlFrBindMajorIfIndex."
::= { juniFrMlFrLinkBindEntry 2 }
juniFrMlFrBindRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrMlFrBindRowStatus
In addition, when creating an entry the following conditions must hold:
The interfaces identified by juniFrMlFrBindNetworkIfIndex and
juniFrMlFrBindLinkIfIndex must be created in the
juniFrMlFrMajorConfigTable and juniFrMlFrLinkConfigTable
respectively.
A MLFR bundle must be associated with the juniFrMlFrMajorIfIndex and
exist in the juniFrMibFrBundleTable.
A corresponding entry in ifStackTable is created/destroyed as a result
of creating/destroying an entry in this table.
Note: This table is read-only table for now. To add links to bundle
make use of juniFrMlFrMajorConfigTable."
::= { juniFrMlFrLinkBindEntry 3 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notifications
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- No notifications are defined in this MIB. Placeholders follow.
-- juniFrTrapControl OBJECT IDENTIFIER ::= { juniFrameRelayMIB 2 }
-- juniFrTraps OBJECT IDENTIFIER ::= { juniFrameRelayMIB 3 }
-- juniFrTrapPrefix OBJECT IDENTIFIER ::= { juniFrTraps 0 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Conformance information
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniFrConformance OBJECT IDENTIFIER ::= { juniFrameRelayMIB 4 }
juniFrCompliances OBJECT IDENTIFIER ::= { juniFrConformance 1 }
juniFrGroups OBJECT IDENTIFIER ::= { juniFrConformance 2 }
--
-- compliance statements
--
juniFrCompliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities that implement the Juniper
Frame Relay MIB. This statement became obsolete when multi-link frame
relay support was added."
MODULE -- this module
MANDATORY-GROUPS {
juniFrGroup,
juniFrSubIfGroup }
::= { juniFrCompliances 1 } -- JUNOSe 1.0
juniFrCompliance2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities that implement the Juniper Frame
Relay MIB."
MODULE -- this module
MANDATORY-GROUPS {
juniFrGroup2,
juniFrSubIfGroup,
juniFrMlFrGroup }
::= { juniFrCompliances 2 } -- JUNOSe 5.0
--
-- units of conformance
--
juniFrGroup OBJECT-GROUP
OBJECTS {
juniFrNextIfIndex,
juniFrDlcmiIfIndex,
juniFrDlcmiState,
juniFrDlcmiAddress,
juniFrDlcmiAddressLen,
juniFrDlcmiPollingInterval,
juniFrDlcmiFullEnquiryInterval,
juniFrDlcmiErrorThreshold,
juniFrDlcmiMonitoredEvents,
juniFrDlcmiMaxSupportedVCs,
juniFrDlcmiMulticast,
juniFrDlcmiStatus,
juniFrDlcmiRowStatus,
juniFrDlcmiLowerIfIndex,
juniFrDlcmiRole,
juniFrDlcmiDcePollingInterval,
juniFrDlcmiDceErrorThreshold,
juniFrDlcmiDceMonitoredEvents,
juniFrDlcmiStatsDteEnquiries,
juniFrDlcmiStatsDteFullEnquiries,
juniFrDlcmiStatsDteEnquiryResponses,
juniFrDlcmiStatsDteFullEnquiryResponses,
juniFrDlcmiStatsDteAsyncUpdates,
juniFrDlcmiStatsDteUnknownRxMessages,
juniFrDlcmiStatsDteLossOfSequences,
juniFrDlcmiStatsDteNoResponseTimeouts,
juniFrDlcmiStatsDceEnquiries,
juniFrDlcmiStatsDceFullEnquiries,
juniFrDlcmiStatsDceEnquiryResponses,
juniFrDlcmiStatsDceFullEnquiryResponses,
juniFrDlcmiStatsDceAsyncUpdates,
juniFrDlcmiStatsDceUnknownRxMessages,
juniFrDlcmiStatsDceLossOfSequences,
juniFrDlcmiStatsDceNoResponseTimeouts,
juniFrDlcmiStatsDiscontinuityTime,
juniFrCircuitState,
juniFrCircuitReceivedFECNs,
juniFrCircuitReceivedBECNs,
juniFrCircuitSentFrames,
juniFrCircuitSentOctets,
juniFrCircuitReceivedFrames,
juniFrCircuitReceivedOctets,
juniFrCircuitCreationTime,
juniFrCircuitLastTimeChange,
juniFrCircuitCommittedBurst,
juniFrCircuitExcessBurst,
juniFrCircuitThroughput,
juniFrCircuitMulticast,
juniFrCircuitType,
juniFrCircuitDiscards,
juniFrCircuitReceivedDEs,
juniFrCircuitSentDEs,
juniFrCircuitLogicalIfIndex,
juniFrCircuitRowStatus,
juniFrCircuitSentFECNs,
juniFrCircuitSentBECNs }
STATUS obsolete
DESCRIPTION
"Obsolete collection of objects providing management of Frame Relay
interfaces in a Juniper product. This group became obsolete when
multi-link frame relay support was added."
::= { juniFrGroups 1 }
juniFrSubIfGroup OBJECT-GROUP
OBJECTS {
juniFrSubIfNextIfIndex,
juniFrSubIfRowStatus,
juniFrSubIfLowerIfIndex,
juniFrSubIfId,
juniFrSubIfCktRowStatus }
STATUS current
DESCRIPTION
"A collection of objects providing management of Frame Relay
subinterfaces in a Juniper product."
::= { juniFrGroups 2 }
juniFrGroup2 OBJECT-GROUP
OBJECTS {
juniFrNextIfIndex,
juniFrDlcmiIfIndex,
juniFrDlcmiState,
juniFrDlcmiAddress,
juniFrDlcmiAddressLen,
juniFrDlcmiPollingInterval,
juniFrDlcmiFullEnquiryInterval,
juniFrDlcmiErrorThreshold,
juniFrDlcmiMonitoredEvents,
juniFrDlcmiMaxSupportedVCs,
juniFrDlcmiMulticast,
juniFrDlcmiStatus,
juniFrDlcmiRowStatus,
juniFrDlcmiLowerIfIndex,
juniFrDlcmiRole,
juniFrDlcmiDcePollingInterval,
juniFrDlcmiDceErrorThreshold,
juniFrDlcmiDceMonitoredEvents,
juniFrDlcmiMultilinkFrBundleName,
juniFrDlcmiStatsDteEnquiries,
juniFrDlcmiStatsDteFullEnquiries,
juniFrDlcmiStatsDteEnquiryResponses,
juniFrDlcmiStatsDteFullEnquiryResponses,
juniFrDlcmiStatsDteAsyncUpdates,
juniFrDlcmiStatsDteUnknownRxMessages,
juniFrDlcmiStatsDteLossOfSequences,
juniFrDlcmiStatsDteNoResponseTimeouts,
juniFrDlcmiStatsDceEnquiries,
juniFrDlcmiStatsDceFullEnquiries,
juniFrDlcmiStatsDceEnquiryResponses,
juniFrDlcmiStatsDceFullEnquiryResponses,
juniFrDlcmiStatsDceAsyncUpdates,
juniFrDlcmiStatsDceUnknownRxMessages,
juniFrDlcmiStatsDceLossOfSequences,
juniFrDlcmiStatsDceNoResponseTimeouts,
juniFrDlcmiStatsDiscontinuityTime,
juniFrCircuitState,
juniFrCircuitReceivedFECNs,
juniFrCircuitReceivedBECNs,
juniFrCircuitSentFrames,
juniFrCircuitSentOctets,
juniFrCircuitReceivedFrames,
juniFrCircuitReceivedOctets,
juniFrCircuitCreationTime,
juniFrCircuitLastTimeChange,
juniFrCircuitCommittedBurst,
juniFrCircuitExcessBurst,
juniFrCircuitThroughput,
juniFrCircuitMulticast,
juniFrCircuitType,
juniFrCircuitDiscards,
juniFrCircuitReceivedDEs,
juniFrCircuitSentDEs,
juniFrCircuitLogicalIfIndex,
juniFrCircuitRowStatus,
juniFrCircuitSentFECNs,
juniFrCircuitSentBECNs }
STATUS current
DESCRIPTION
"A collection of objects providing management of Frame Relay interfaces
in a Juniper product."
::= { juniFrGroups 3 }
juniFrMlFrGroup OBJECT-GROUP
OBJECTS {
juniFrMlFrBundleRowStatus,
juniFrMlFrNextLinkIfIndex,
juniFrMlFrLinkConfigLowerIfIndex,
juniFrMlFrLinkConfigRowStatus,
juniFrMlFrMajorConfigLowerIfIndex,
juniFrMlFrMajorBundleName,
juniFrMlFrMajorRowStatus,
juniFrMlFrBindRowStatus }
STATUS current
DESCRIPTION
"A collection of objects providing management of Multilink Frame Relay
in a Juniper product."
::= { juniFrGroups 4 }
END