-- Juniper-FRAME-RELAY-MIB
|
||
|
--
|
||
|
-- Juniper Networks Enterprise MIB
|
||
|
-- Frame Relay MIB
|
||
|
--
|
||
|
-- Copyright (c) 1998, 1999 Redstone Communications, Inc.
|
||
|
-- Copyright (c) 2000 Unisphere Networks, Inc.
|
||
|
-- Copyright (c) 2002 Juniper Networks, Inc.
|
||
|
-- Copyright (c) 2004 Juniper Networks, Inc.
|
||
|
-- All Rights Reserved.
|
||
|
-- *****************************************************************************
|
||
|
|
||
|
Juniper-FRAME-RELAY-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32, TimeTicks
|
||
|
FROM SNMPv2-SMI
|
||
|
TEXTUAL-CONVENTION, RowStatus, TimeStamp
|
||
|
FROM SNMPv2-TC
|
||
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
||
|
FROM SNMPv2-CONF
|
||
|
InterfaceIndex, InterfaceIndexOrZero
|
||
|
FROM IF-MIB
|
||
|
DLCI
|
||
|
FROM FRAME-RELAY-DTE-MIB
|
||
|
juniMibs
|
||
|
FROM Juniper-MIBs
|
||
|
JuniNextIfIndex
|
||
|
FROM Juniper-TC;
|
||
|
|
||
|
juniFrameRelayMIB MODULE-IDENTITY
|
||
|
LAST-UPDATED "200212131435Z" -- 13-Dec-02 09:35 AM EST
|
||
|
ORGANIZATION "Juniper Networks, Inc."
|
||
|
CONTACT-INFO
|
||
|
" Juniper Networks, Inc.
|
||
|
Postal: 10 Technology Park Drive
|
||
|
Westford MA 01886-3146
|
||
|
USA
|
||
|
Tel: +1 978 589 5800
|
||
|
Email: mib@Juniper.net"
|
||
|
DESCRIPTION
|
||
|
"The Frame Relay MIB for the Juniper Networks enterprise."
|
||
|
-- Revision History
|
||
|
REVISION "200212131435Z" -- 13-Dec-02 09:35 AM EST - JUNOSe 5.0
|
||
|
DESCRIPTION
|
||
|
"Replaced Unisphere names with Juniper names.
|
||
|
Added multi-link support."
|
||
|
REVISION "200009261730Z" -- 26-Sep-00 01:30 PM EDT - JUNOSe 3.0
|
||
|
DESCRIPTION
|
||
|
"Make it SMIv2 conformant."
|
||
|
REVISION "9906010000Z" -- 01-Jun-99 - JUNOSe 1.1
|
||
|
DESCRIPTION
|
||
|
"Add support for NNI behavior."
|
||
|
REVISION "9811130000Z" -- 13-Nov-98 - JUNOSe 1.0
|
||
|
DESCRIPTION
|
||
|
"Initial version of this MIB module."
|
||
|
::= { juniMibs 10 }
|
||
|
|
||
|
|
||
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||
|
-- Textual conventions
|
||
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||
|
JuniFrMlFrBundleName ::= TEXTUAL-CONVENTION
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"MLFR Bundle name. The bundle name is a characteristic of a MLFR frame
|
||
|
relay interface.
|
||
|
|
||
|
Represents textual information taken from the NVT ASCII graphics
|
||
|
character set (codes 32 through 126)."
|
||
|
REFERENCE
|
||
|
"RFC 854: NVT ASCII character set."
|
||
|
SYNTAX OCTET STRING (SIZE(0..32))
|
||
|
|
||
|
|
||
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||
|
-- Managed objects
|
||
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||
|
juniFrObjects OBJECT IDENTIFIER ::= { juniFrameRelayMIB 1 }
|
||
|
|
||
|
--
|
||
|
-- This MIB contains managed objects for each of two interface
|
||
|
-- layers: Frame Relay interfaces, and Frame Relay subinterfaces.
|
||
|
-- For each of these layers, management objects are provided to
|
||
|
-- query for an available interface index, and to create/delete
|
||
|
-- interfaces of that type. Creating/deleting these interface
|
||
|
-- types using this MIB has the side effect of creating/deleting
|
||
|
-- corresponding entries in the Interface MIB ifTable/ifXTable,
|
||
|
-- and in the Juniper Enterprise Interface MIB juniIfTable.
|
||
|
--
|
||
|
juniFrIfLayer OBJECT IDENTIFIER ::= { juniFrObjects 1 }
|
||
|
juniFrSubIfLayer OBJECT IDENTIFIER ::= { juniFrObjects 2 }
|
||
|
juniFrMlFr OBJECT IDENTIFIER ::= { juniFrObjects 3 }
|
||
|
|
||
|
|
||
|
-- /////////////////////////////////////////////////////////////////////////////
|
||
|
--
|
||
|
-- Frame Relay Interface Layer
|
||
|
--
|
||
|
-- This layer is managed with the following elements:
|
||
|
--
|
||
|
-- o NextIfIndex (generator for Frame Relay IfIndex selection)
|
||
|
-- o DLCMI Table (creation/configuration/deletion of Frame Relay interfaces)
|
||
|
-- o DLCMI Statistics Table (Frame Relay interface statistics)
|
||
|
-- o Circuit Table (status of Frame Relay circuits)
|
||
|
--
|
||
|
-- /////////////////////////////////////////////////////////////////////////////
|
||
|
--
|
||
|
-- IfIndex selection for creating new Frame Relay interfaces
|
||
|
--
|
||
|
juniFrNextIfIndex OBJECT-TYPE
|
||
|
SYNTAX JuniNextIfIndex
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Coordinate ifIndex value allocation for entries in juniFrDlcmiTable.
|
||
|
|
||
|
A GET of this object returns the next available ifIndex value to be used
|
||
|
to create an entry in the associated interface table; or zero, if no
|
||
|
valid ifIndex value is available. This object also returns a value of
|
||
|
zero when it is the lexicographic successor of a varbind presented in an
|
||
|
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
|
||
|
that ifIndex allocation is unintended.
|
||
|
|
||
|
Successive GETs will typically return different values, thus avoiding
|
||
|
collisions among cooperating management clients seeking to create table
|
||
|
entries simultaneously."
|
||
|
::= { juniFrIfLayer 1 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- The Frame Relay DLCMI Table
|
||
|
--
|
||
|
juniFrDlcmiTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF JuniFrDlcmiEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The Parameters for the Data Link Connection Management Interface for
|
||
|
the frame relay service on this interface.
|
||
|
|
||
|
This table represents a superset of functionality specified in the
|
||
|
FRAME-RELAY-DTE-MIB. In particular, it adds attributes that permit the
|
||
|
interface to operate as a network-side (DCE) interface."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.617-1991, Annex D"
|
||
|
::= { juniFrIfLayer 2 }
|
||
|
|
||
|
juniFrDlcmiEntry OBJECT-TYPE
|
||
|
SYNTAX JuniFrDlcmiEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The Parameters for a particular Data Link Connection Management
|
||
|
Interface.
|
||
|
|
||
|
Creating/deleting entries in this table causes corresponding entries for
|
||
|
be created/deleted in ifTable/ifXTable/juniIfTable, and
|
||
|
juniFrDlcmiStatsTable.
|
||
|
|
||
|
Creating/deleting user-side (DTE) entries in this table also causes
|
||
|
coresponding entries to be created/deleted in
|
||
|
FRAME-RELAY-DTE-MIB.frDlcmiTable.
|
||
|
|
||
|
The organization and definitions of objects in this table are
|
||
|
intentionally aligned closely to those in FRAME-RELAY-DTE-MIB."
|
||
|
INDEX { juniFrDlcmiIfIndex }
|
||
|
::= { juniFrDlcmiTable 1 }
|
||
|
|
||
|
JuniFrDlcmiEntry ::= SEQUENCE {
|
||
|
juniFrDlcmiIfIndex InterfaceIndex,
|
||
|
juniFrDlcmiState INTEGER,
|
||
|
juniFrDlcmiAddress INTEGER,
|
||
|
juniFrDlcmiAddressLen INTEGER,
|
||
|
juniFrDlcmiPollingInterval Integer32,
|
||
|
juniFrDlcmiFullEnquiryInterval Integer32,
|
||
|
juniFrDlcmiErrorThreshold Integer32,
|
||
|
juniFrDlcmiMonitoredEvents Integer32,
|
||
|
juniFrDlcmiMaxSupportedVCs DLCI,
|
||
|
juniFrDlcmiMulticast INTEGER,
|
||
|
juniFrDlcmiStatus INTEGER,
|
||
|
juniFrDlcmiRowStatus RowStatus,
|
||
|
juniFrDlcmiLowerIfIndex InterfaceIndexOrZero,
|
||
|
juniFrDlcmiRole INTEGER,
|
||
|
juniFrDlcmiDcePollingInterval Integer32,
|
||
|
juniFrDlcmiDceErrorThreshold Integer32,
|
||
|
juniFrDlcmiDceMonitoredEvents Integer32,
|
||
|
juniFrDlcmiMultilinkFrBundleName JuniFrMlFrBundleName }
|
||
|
|
||
|
juniFrDlcmiIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndex
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ifIndex value of the corresponding ifEntry."
|
||
|
::= { juniFrDlcmiEntry 1 }
|
||
|
|
||
|
juniFrDlcmiState OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
noLmiConfigured(1),
|
||
|
lmiRev1(2),
|
||
|
ansiT1617D(3), -- ANSI T1.617 Annex D
|
||
|
ansiT1617B(4), -- ANSI T1.617 Annex B
|
||
|
itut933A(5), -- ITU-T Q933 Annex A
|
||
|
ansiT1617D1994(6) } -- ANSI T1.617a-1994 Annex D
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable states which Data Link Connection Management scheme is
|
||
|
active (and by implication, what DLCI it uses) on the Frame Relay
|
||
|
interface."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.617-1991, American National Standard
|
||
|
T1.617a-1994, ITU-T Recommendation Q.933 (03/93)."
|
||
|
::= { juniFrDlcmiEntry 2 }
|
||
|
|
||
|
juniFrDlcmiAddress OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
q921(1), -- 13 bit DLCI
|
||
|
q922March90(2), -- 11 bit DLCI
|
||
|
q922November90(3), -- 10 bit DLCI
|
||
|
q922(4) } -- Final Standard
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable states which address format is in use on the Frame Relay
|
||
|
interface."
|
||
|
DEFVAL { q922 }
|
||
|
::= { juniFrDlcmiEntry 3 }
|
||
|
|
||
|
juniFrDlcmiAddressLen OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
twoOctets(2),
|
||
|
threeOctets(3),
|
||
|
fourOctets(4) }
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable states the address length in octets. In the case of Q922
|
||
|
format, the length indicates the entire length of the address including
|
||
|
the control portion."
|
||
|
DEFVAL { twoOctets }
|
||
|
::= { juniFrDlcmiEntry 4 }
|
||
|
|
||
|
juniFrDlcmiPollingInterval OBJECT-TYPE
|
||
|
SYNTAX Integer32 (5..30)
|
||
|
UNITS "seconds"
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This is the number of seconds between successive status enquiry
|
||
|
messages sent by the DTE.
|
||
|
|
||
|
Pertains to DTE/NNI operation only. This parameter can be reconfigured
|
||
|
only when the Frame Relay interface is acting as a DTE or NNI."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.617-1991, Section D.7 Timer T391."
|
||
|
DEFVAL { 10 }
|
||
|
::= { juniFrDlcmiEntry 5 }
|
||
|
|
||
|
juniFrDlcmiFullEnquiryInterval OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..255)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of status enquiry intervals that pass before issuance of a full
|
||
|
status enquiry message.
|
||
|
|
||
|
Pertains to DTE/NNI operation only. This parameter can be reconfigured
|
||
|
only when the Frame Relay interface is acting as a DTE or NNI."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.617-1991, Section D.7 Counter N391."
|
||
|
DEFVAL { 6 }
|
||
|
::= { juniFrDlcmiEntry 6 }
|
||
|
|
||
|
juniFrDlcmiErrorThreshold OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..10)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The minimum number of errors that must be observed within the number of
|
||
|
events specified by juniFrDlcmiMonitoredEvents, to declare the interface
|
||
|
down.
|
||
|
|
||
|
'error' is lack of receipt of a Status, in response to an issued Status
|
||
|
Enquiry, within the Polling Interval (T391).
|
||
|
|
||
|
Pertains to DTE/NNI operation only. This parameter can be reconfigured
|
||
|
only when the Frame Relay interface is acting as a DTE or NNI."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.617-1991, Section D.5.1 Counter N392."
|
||
|
DEFVAL { 3 }
|
||
|
::= { juniFrDlcmiEntry 7 }
|
||
|
|
||
|
juniFrDlcmiMonitoredEvents OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..10)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of status polling intervals over which the error threshold
|
||
|
is counted. For example, if within 'MonitoredEvents' number of events
|
||
|
the station receives 'ErrorThreshold' number of errors, the interface is
|
||
|
marked as down.
|
||
|
|
||
|
'status polling interval' is specified by juniFrDlcmiPollingInterval.
|
||
|
|
||
|
Pertains to DTE/NNI operation only. This parameter can be reconfigured
|
||
|
only when the Frame Relay interface is acting as a DTE or NNI."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.617-1991, Section D.5.2 Counter N393."
|
||
|
DEFVAL { 4 }
|
||
|
::= { juniFrDlcmiEntry 8 }
|
||
|
|
||
|
juniFrDlcmiMaxSupportedVCs OBJECT-TYPE
|
||
|
SYNTAX DLCI
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The maximum number of Virtual Circuits allowed for this interface.
|
||
|
Usually dictated by the Frame Relay network.
|
||
|
|
||
|
In response to a SET, if a value less than zero or higher than the
|
||
|
agent's maximal capability is configured, the agent should respond
|
||
|
badValue."
|
||
|
::= { juniFrDlcmiEntry 9 }
|
||
|
|
||
|
juniFrDlcmiMulticast OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
nonBroadcast(1),
|
||
|
broadcast(2) }
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This indicates whether the Frame Relay interface is using a multicast
|
||
|
service."
|
||
|
DEFVAL { nonBroadcast }
|
||
|
::= { juniFrDlcmiEntry 10 }
|
||
|
|
||
|
juniFrDlcmiStatus OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
running(1), -- init complete, system running
|
||
|
fault(2), -- error threshold exceeded
|
||
|
initializing(3) } -- system start up
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This indicates the status of the Frame Relay interface as determined by
|
||
|
the performance of the DLCMI. If no DLCMI is running, the Frame Relay
|
||
|
interface will stay in the running state indefinitely."
|
||
|
::= { juniFrDlcmiEntry 11 }
|
||
|
|
||
|
juniFrDlcmiRowStatus OBJECT-TYPE
|
||
|
SYNTAX RowStatus
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Controls creation/deletion of entries in this table according to the
|
||
|
RowStatus textual convention, constrained to support the following
|
||
|
values only:
|
||
|
createAndGo
|
||
|
destroy
|
||
|
|
||
|
To create an entry in this table, the following entry objects MUST be
|
||
|
explicitly configured:
|
||
|
juniFrDlcmiRowStatus
|
||
|
juniFrDlcmiState
|
||
|
juniFrDlcmiMaxSupportedVCs
|
||
|
juniFrDlcmiLowerIfIndex
|
||
|
juniFrDlcmiRole
|
||
|
juniFrDlcmiMultilinkFrBundleName (Only for multilink frame relay)
|
||
|
|
||
|
In addition, when creating an entry the following conditions must hold:
|
||
|
|
||
|
A value for juniFrDlcmiIndex must have been determined previously,
|
||
|
by reading juniFrNextIfIndex.
|
||
|
|
||
|
The interface identified by juniFrDlcmiLowerIfIndex must exist, and
|
||
|
must be an interface type that permits layering of Frame Relay above
|
||
|
it.
|
||
|
|
||
|
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
|
||
|
destroyed as a result of creating/destroying an entry in this table. If
|
||
|
juniFrDlcmiRole is dte(0), a corresponding entry is created/deleted in
|
||
|
frDlcmiTable."
|
||
|
::= { juniFrDlcmiEntry 12 }
|
||
|
|
||
|
juniFrDlcmiLowerIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndexOrZero
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ifIndex of an interface over which this Frame Relay interface is to
|
||
|
be layered. A value of zero indicates no layering. An implementation
|
||
|
may choose to require that a nonzero value be configured at entry
|
||
|
creation. In case of multilink frame relay support, it will be
|
||
|
multilink frame relay interface's ifIndex."
|
||
|
::= { juniFrDlcmiEntry 13 }
|
||
|
|
||
|
juniFrDlcmiRole OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
dte(0),
|
||
|
dce(1),
|
||
|
nni(2) }
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Specifies the role this interface assumes with respect to the remote
|
||
|
end.
|
||
|
|
||
|
When acting as a DTE, the following objects are not relevant:
|
||
|
juniFrDlcmiDcePollingInterval
|
||
|
juniFrDlcmiDceErrorThreshold
|
||
|
juniFrDlcmiDceMonitoredEvents
|
||
|
|
||
|
When acting as a DCE, the following objects are not relevant:
|
||
|
juniFrDlcmiPollingInterval
|
||
|
juniFrDlcmiFullEnquiryInterval
|
||
|
juniFrDlcmiErrorThreshold
|
||
|
juniFrDlcmiMonitoredEvents "
|
||
|
::= { juniFrDlcmiEntry 14 }
|
||
|
|
||
|
juniFrDlcmiDcePollingInterval OBJECT-TYPE
|
||
|
SYNTAX Integer32 (5..30)
|
||
|
UNITS "seconds"
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
|
||
|
"The number of seconds within which a DCE expects to receive a Status
|
||
|
Enquiry from the DTE.
|
||
|
|
||
|
This value corresponds to the T392 timer.
|
||
|
|
||
|
Pertains to DCE/NNI operation only. This parameter can be reconfigured
|
||
|
only when the Frame Relay interface is acting as a DCE or NNI."
|
||
|
DEFVAL { 15 }
|
||
|
::= { juniFrDlcmiEntry 15 }
|
||
|
|
||
|
juniFrDlcmiDceErrorThreshold OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..10)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The minimum number of errors that must be observed within the number of
|
||
|
events specified by juniFrDlcmiDceMonitoredEvents, to declare the
|
||
|
interface down.
|
||
|
|
||
|
'error' is lack of receipt of a Status Enquiry within the interval
|
||
|
specified by juniFrDlcmiDcePollingInterval (T392).
|
||
|
|
||
|
Pertains to DCE/NNI operation only. This parameter can be reconfigured
|
||
|
only when the Frame Relay interface is acting as a DCE or NNI."
|
||
|
DEFVAL { 2 }
|
||
|
::= { juniFrDlcmiEntry 16 }
|
||
|
|
||
|
juniFrDlcmiDceMonitoredEvents OBJECT-TYPE
|
||
|
SYNTAX Integer32 (1..10)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of DCE polling intervals over which accumulated errors are
|
||
|
counted against the threshold specified in juniFrDlcmiDceErrorThreshold.
|
||
|
|
||
|
If, within this number of events, the number of errors equals or exceeds
|
||
|
the threshold, the interface is declared down.
|
||
|
|
||
|
The 'DCE polling interval' is specified by
|
||
|
juniFrDlcmiDcePollingInterval.
|
||
|
|
||
|
Pertains to DCE/NNI operation only. This parameter can be reconfigured
|
||
|
only when the Frame Relay interface is acting as a DCE or NNI."
|
||
|
DEFVAL { 2 }
|
||
|
::= { juniFrDlcmiEntry 17 }
|
||
|
|
||
|
juniFrDlcmiMultilinkFrBundleName OBJECT-TYPE
|
||
|
SYNTAX JuniFrMlFrBundleName
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This represents multilink frame relay bundle name. This object must be
|
||
|
configured to associate the bundle name to the frame relay major
|
||
|
interface to support the multilink frame relay encapsulation. For
|
||
|
non-multilink frame relay, bundle name configuration is not valid and
|
||
|
will be ignored."
|
||
|
DEFVAL { "" }
|
||
|
::= { juniFrDlcmiEntry 18 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- The Frame Relay Data Link Connection Management Interface (DLCMI) Statistics
|
||
|
-- Table
|
||
|
--
|
||
|
juniFrDlcmiStatsTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF JuniFrDlcmiStatsEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The statistics for the Data Link Connection Management Interface for
|
||
|
the frame relay service on this interface."
|
||
|
::= { juniFrIfLayer 3 }
|
||
|
|
||
|
juniFrDlcmiStatsEntry OBJECT-TYPE
|
||
|
SYNTAX JuniFrDlcmiStatsEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The statistics for a particular Data Link Connection Management
|
||
|
Interface.
|
||
|
|
||
|
Statistics are not relevant while the juniFrDlcmiState has the value
|
||
|
'noLmiConfigured'.
|
||
|
|
||
|
The DTE statistics are relevant when the corresponding juniFrDlcmiRole
|
||
|
is DTE.
|
||
|
|
||
|
The DTE statistics are relevant when the corresponding juniFrDlcmiRole
|
||
|
is DCE."
|
||
|
INDEX { juniFrDlcmiIfIndex }
|
||
|
::= { juniFrDlcmiStatsTable 1 }
|
||
|
|
||
|
JuniFrDlcmiStatsEntry ::= SEQUENCE {
|
||
|
juniFrDlcmiStatsDteEnquiries Counter32,
|
||
|
juniFrDlcmiStatsDteFullEnquiries Counter32,
|
||
|
juniFrDlcmiStatsDteEnquiryResponses Counter32,
|
||
|
juniFrDlcmiStatsDteFullEnquiryResponses Counter32,
|
||
|
juniFrDlcmiStatsDteAsyncUpdates Counter32,
|
||
|
juniFrDlcmiStatsDteUnknownRxMessages Counter32,
|
||
|
juniFrDlcmiStatsDteLossOfSequences Counter32,
|
||
|
juniFrDlcmiStatsDteNoResponseTimeouts Counter32,
|
||
|
|
||
|
juniFrDlcmiStatsDceEnquiries Counter32,
|
||
|
juniFrDlcmiStatsDceFullEnquiries Counter32,
|
||
|
juniFrDlcmiStatsDceEnquiryResponses Counter32,
|
||
|
juniFrDlcmiStatsDceFullEnquiryResponses Counter32,
|
||
|
juniFrDlcmiStatsDceAsyncUpdates Counter32,
|
||
|
juniFrDlcmiStatsDceUnknownRxMessages Counter32,
|
||
|
juniFrDlcmiStatsDceLossOfSequences Counter32,
|
||
|
juniFrDlcmiStatsDceNoResponseTimeouts Counter32,
|
||
|
|
||
|
juniFrDlcmiStatsDiscontinuityTime TimeTicks }
|
||
|
|
||
|
juniFrDlcmiStatsDteEnquiries OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of Status Enquiries sent (as DTE)."
|
||
|
::= { juniFrDlcmiStatsEntry 1 }
|
||
|
|
||
|
juniFrDlcmiStatsDteFullEnquiries OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of Full Enquiries sent (as DTE)."
|
||
|
::= { juniFrDlcmiStatsEntry 2 }
|
||
|
|
||
|
juniFrDlcmiStatsDteEnquiryResponses OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of Status Enquiry responses received (as DTE)."
|
||
|
::= { juniFrDlcmiStatsEntry 3 }
|
||
|
|
||
|
juniFrDlcmiStatsDteFullEnquiryResponses OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of Full Enquiry responses received (as DTE)."
|
||
|
::= { juniFrDlcmiStatsEntry 4 }
|
||
|
|
||
|
juniFrDlcmiStatsDteAsyncUpdates OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of Asynchronous Updates received (as DTE)."
|
||
|
::= { juniFrDlcmiStatsEntry 5 }
|
||
|
|
||
|
juniFrDlcmiStatsDteUnknownRxMessages OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of unknown messages received (as DTE)."
|
||
|
::= { juniFrDlcmiStatsEntry 6 }
|
||
|
|
||
|
juniFrDlcmiStatsDteLossOfSequences OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of times a discontinuity in sequence numbering of received
|
||
|
messages was detected (as DTE)."
|
||
|
::= { juniFrDlcmiStatsEntry 7 }
|
||
|
|
||
|
juniFrDlcmiStatsDteNoResponseTimeouts OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of timer expirations awaiting a Status message (as DTE)."
|
||
|
::= { juniFrDlcmiStatsEntry 8 }
|
||
|
|
||
|
juniFrDlcmiStatsDceEnquiries OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of Status Enquiries received (as DCE.)"
|
||
|
::= { juniFrDlcmiStatsEntry 9 }
|
||
|
|
||
|
juniFrDlcmiStatsDceFullEnquiries OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of Full Enquiries received (as DCE)."
|
||
|
::= { juniFrDlcmiStatsEntry 10 }
|
||
|
|
||
|
juniFrDlcmiStatsDceEnquiryResponses OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of Status Enquiry responses sent (as DCE)."
|
||
|
::= { juniFrDlcmiStatsEntry 11 }
|
||
|
|
||
|
juniFrDlcmiStatsDceFullEnquiryResponses OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of Full Enquiry responses sent (as DCE)."
|
||
|
::= { juniFrDlcmiStatsEntry 12 }
|
||
|
|
||
|
juniFrDlcmiStatsDceAsyncUpdates OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of Asynchronous Updates sent (as DCE)."
|
||
|
::= { juniFrDlcmiStatsEntry 13 }
|
||
|
|
||
|
juniFrDlcmiStatsDceUnknownRxMessages OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of unknown messages received (as DCE)."
|
||
|
::= { juniFrDlcmiStatsEntry 14 }
|
||
|
|
||
|
juniFrDlcmiStatsDceLossOfSequences OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of times a discontinuity in sequence numbering of received
|
||
|
messages was detected (as DCE)."
|
||
|
::= { juniFrDlcmiStatsEntry 15 }
|
||
|
|
||
|
juniFrDlcmiStatsDceNoResponseTimeouts OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of timer expirations awaiting a Status Enquiry (as DCE)."
|
||
|
::= { juniFrDlcmiStatsEntry 16 }
|
||
|
|
||
|
juniFrDlcmiStatsDiscontinuityTime OBJECT-TYPE
|
||
|
SYNTAX TimeTicks
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
|
||
|
"Value of sysUpTime at the most recent event that caused a discontinuity
|
||
|
in the monotonic operation of any of the counters in this entry. Such
|
||
|
disruption might be caused by:
|
||
|
Hardware insertion/removal.
|
||
|
Reconfiguration of juniFrDlcmiState.
|
||
|
Reconfiguration of juniFrDlcmiRole.
|
||
|
|
||
|
Conclusions can be drawn from successive polls of an entry's counters
|
||
|
only if the value of this object, simultaneously retrieved in those
|
||
|
polls, remains unchanged."
|
||
|
::= { juniFrDlcmiStatsEntry 17 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- Frame Relay Circuit Table
|
||
|
--
|
||
|
juniFrCircuitTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF JuniFrCircuitEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A table containing information about specific Data Link Connections
|
||
|
(DLC) or virtual circuits.
|
||
|
|
||
|
This table mirrors the structure of FRAME-RELAY-DTE-MIB.frCircuitTable,
|
||
|
for the purpose of enumerating circuits on both DTE and DCE Frame Relay
|
||
|
interfaces."
|
||
|
::= { juniFrIfLayer 4 }
|
||
|
|
||
|
juniFrCircuitEntry OBJECT-TYPE
|
||
|
SYNTAX JuniFrCircuitEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The information regarding a single Data Link Connection.
|
||
|
Discontinuities in the counters contained in this table are indicated by
|
||
|
the value in juniFrCircuitCreationTime."
|
||
|
INDEX { juniFrCircuitIfIndex,
|
||
|
juniFrCircuitDlci }
|
||
|
::= { juniFrCircuitTable 1 }
|
||
|
|
||
|
JuniFrCircuitEntry ::= SEQUENCE {
|
||
|
juniFrCircuitIfIndex InterfaceIndex,
|
||
|
juniFrCircuitDlci DLCI,
|
||
|
juniFrCircuitState INTEGER,
|
||
|
juniFrCircuitReceivedFECNs Counter32,
|
||
|
juniFrCircuitReceivedBECNs Counter32,
|
||
|
juniFrCircuitSentFrames Counter32,
|
||
|
juniFrCircuitSentOctets Counter32,
|
||
|
juniFrCircuitReceivedFrames Counter32,
|
||
|
juniFrCircuitReceivedOctets Counter32,
|
||
|
juniFrCircuitCreationTime TimeStamp,
|
||
|
juniFrCircuitLastTimeChange TimeStamp,
|
||
|
juniFrCircuitCommittedBurst Integer32,
|
||
|
juniFrCircuitExcessBurst Integer32,
|
||
|
juniFrCircuitThroughput Integer32,
|
||
|
juniFrCircuitMulticast INTEGER,
|
||
|
juniFrCircuitType INTEGER,
|
||
|
juniFrCircuitDiscards Counter32,
|
||
|
juniFrCircuitReceivedDEs Counter32,
|
||
|
juniFrCircuitSentDEs Counter32,
|
||
|
juniFrCircuitLogicalIfIndex InterfaceIndex,
|
||
|
juniFrCircuitRowStatus RowStatus,
|
||
|
juniFrCircuitSentFECNs Counter32,
|
||
|
juniFrCircuitSentBECNs Counter32 }
|
||
|
|
||
|
juniFrCircuitIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndex
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ifIndex Value of the ifEntry this virtual circuit is layered onto."
|
||
|
::= { juniFrCircuitEntry 1 }
|
||
|
|
||
|
juniFrCircuitDlci OBJECT-TYPE
|
||
|
SYNTAX DLCI
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The Data Link Connection Identifier for this virtual circuit."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.618-1991, Section 3.3.6"
|
||
|
::= { juniFrCircuitEntry 2 }
|
||
|
|
||
|
juniFrCircuitState OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
invalid(1),
|
||
|
active(2),
|
||
|
inactive(3) }
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indicates whether the particular virtual circuit is operational. In
|
||
|
the absence of a Data Link Connection Management Interface, virtual
|
||
|
circuit entries (rows) may be created by setting virtual circuit state
|
||
|
to 'active', or deleted by changing Circuit state to 'invalid'.
|
||
|
|
||
|
Whether or not the row actually disappears is left to the
|
||
|
implementation, so this object may actually read as 'invalid' for some
|
||
|
arbitrary length of time. It is also legal to set the state of a
|
||
|
virtual circuit to 'inactive' to temporarily disable a given circuit.
|
||
|
|
||
|
The use of 'invalid' is deprecated in this SNMP Version 2 MIB, in favor
|
||
|
of juniFrCircuitRowStatus."
|
||
|
DEFVAL { active }
|
||
|
::= { juniFrCircuitEntry 3 }
|
||
|
|
||
|
juniFrCircuitReceivedFECNs OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of frames received from the network indicating forward
|
||
|
congestion since the virtual circuit was created. This occurs when the
|
||
|
remote DTE sets the FECN flag, or when a switch in the network enqueues
|
||
|
the frame to a trunk whose transmission queue is congested."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.618-1991, Section 3.3.3"
|
||
|
::= { juniFrCircuitEntry 4 }
|
||
|
|
||
|
juniFrCircuitReceivedBECNs OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of frames received from the network indicating backward
|
||
|
congestion since the virtual circuit was created. This occurs when the
|
||
|
remote DTE sets the BECN flag, or when a switch in the network receives
|
||
|
the frame from a trunk whose transmission queue is congested."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.618-1991, Section 3.3.4"
|
||
|
::= { juniFrCircuitEntry 5 }
|
||
|
|
||
|
juniFrCircuitSentFrames OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of frames sent from this virtual circuit since it was
|
||
|
created."
|
||
|
::= { juniFrCircuitEntry 6 }
|
||
|
|
||
|
juniFrCircuitSentOctets OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of octets sent from this virtual circuit since it was
|
||
|
created. Octets counted are the full frame relay header and the
|
||
|
payload, but do not include the flag characters or CRC."
|
||
|
::= { juniFrCircuitEntry 7 }
|
||
|
|
||
|
juniFrCircuitReceivedFrames OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of frames received over this virtual circuit since it was
|
||
|
created."
|
||
|
::= { juniFrCircuitEntry 8 }
|
||
|
|
||
|
juniFrCircuitReceivedOctets OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of octets received over this virtual circuit since it was
|
||
|
created. Octets counted include the full frame relay header, but do not
|
||
|
include the flag characters or the CRC."
|
||
|
::= { juniFrCircuitEntry 9 }
|
||
|
|
||
|
juniFrCircuitCreationTime OBJECT-TYPE
|
||
|
SYNTAX TimeStamp
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of sysUpTime when the virtual circuit was created, whether by
|
||
|
the Data Link Connection Management Interface or by a SetRequest."
|
||
|
::= { juniFrCircuitEntry 10 }
|
||
|
|
||
|
juniFrCircuitLastTimeChange OBJECT-TYPE
|
||
|
SYNTAX TimeStamp
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The value of sysUpTime when last there was a change in the virtual
|
||
|
circuit state"
|
||
|
::= { juniFrCircuitEntry 11 }
|
||
|
|
||
|
juniFrCircuitCommittedBurst OBJECT-TYPE
|
||
|
SYNTAX Integer32 (0..2147483647)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates the maximum amount of data, in bits, that the
|
||
|
network agrees to transfer under normal conditions, during the
|
||
|
measurement interval. A value of zero (the default) indicates no
|
||
|
commitment."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.617-1991, Section 6.5.19"
|
||
|
DEFVAL { 0 }
|
||
|
::= { juniFrCircuitEntry 12 }
|
||
|
|
||
|
juniFrCircuitExcessBurst OBJECT-TYPE
|
||
|
SYNTAX Integer32 (0..2147483647)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This variable indicates the maximum amount of uncommitted data bits
|
||
|
that the network will attempt to deliver over the measurement interval.
|
||
|
|
||
|
By default, if not configured when creating the entry, the Excess
|
||
|
Information Burst Size is set to the value of ifSpeed."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.617-1991, Section 6.5.19"
|
||
|
::= { juniFrCircuitEntry 13 }
|
||
|
|
||
|
juniFrCircuitThroughput OBJECT-TYPE
|
||
|
SYNTAX Integer32 (0..2147483647)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Throughput is the average number of 'Frame Relay Information Field'
|
||
|
bits transferred per second across a user network interface in one
|
||
|
direction, measured over the measurement interval.
|
||
|
|
||
|
If the configured committed burst rate and throughput are both non-zero,
|
||
|
the measurement interval, T, is
|
||
|
|
||
|
T = juniFrCircuitCommittedBurst / juniFrCircuitThroughput.
|
||
|
|
||
|
If the configured committed burst rate and throughput are both zero, the
|
||
|
measurement interval, T, is
|
||
|
|
||
|
T = juniFrCircuitExcessBurst / ifSpeed
|
||
|
|
||
|
A value of zero (the default) for throughput indicates no commitment."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.617-1991, Section 6.5.19"
|
||
|
DEFVAL { 0 }
|
||
|
::= { juniFrCircuitEntry 14 }
|
||
|
|
||
|
juniFrCircuitMulticast OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
unicast(1),
|
||
|
oneWay(2),
|
||
|
twoWay(3),
|
||
|
nWay(4) }
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This indicates whether this VC is used as a unicast VC (i.e. not
|
||
|
multicast) or the type of multicast service subscribed to."
|
||
|
REFERENCE
|
||
|
"Frame Relay PVC Multicast Service and Protocol Description
|
||
|
Implementation: FRF.7 Frame Relay Forum Technical Committe October 21,
|
||
|
1994"
|
||
|
DEFVAL { unicast }
|
||
|
::= { juniFrCircuitEntry 15 }
|
||
|
|
||
|
juniFrCircuitType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
static(1),
|
||
|
dynamic(2) }
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Indication of whether the VC was manually created (static), or
|
||
|
dynamically created (dynamic) via the data link control management
|
||
|
interface."
|
||
|
::= { juniFrCircuitEntry 16 }
|
||
|
|
||
|
juniFrCircuitDiscards OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The number of inbound frames dropped because of format errors, or
|
||
|
because the VC is inactive."
|
||
|
::= { juniFrCircuitEntry 17 }
|
||
|
|
||
|
juniFrCircuitReceivedDEs OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of frames received from the network indicating that they were
|
||
|
eligible for discard since the virtual circuit was created. This occurs
|
||
|
when the remote DTE sets the DE flag, or when in remote DTE's switch
|
||
|
detects that the frame was received as Excess Burst data."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.618-1991, Section 3.3.4"
|
||
|
::= { juniFrCircuitEntry 18 }
|
||
|
|
||
|
juniFrCircuitSentDEs OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of frames sent to the network indicating that they were eligible
|
||
|
for discard since the virtual circuit was created. This occurs when the
|
||
|
local DTE sets the DE flag, indicating that during Network congestion
|
||
|
situations those frames should be discarded in preference of other
|
||
|
frames sent without the DE bit set."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.618-1991, Section 3.3.4"
|
||
|
::= { juniFrCircuitEntry 19 }
|
||
|
|
||
|
juniFrCircuitLogicalIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndex
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Normally the same value as frDlcmiIfIndex, but different when an
|
||
|
implementation associates a virtual ifEntry with a DLC or set of DLCs in
|
||
|
order to associate higher layer objects such as the ipAddrEntry with a
|
||
|
subset of the virtual circuits on a Frame Relay interface. The type of
|
||
|
such ifEntries is defined by the higher layer object; for example, if
|
||
|
PPP/Frame Relay is implemented, the ifType of this ifEntry would be PPP.
|
||
|
If it is not so defined, as would be the case with an ipAddrEntry, it
|
||
|
should be of type Other."
|
||
|
::= { juniFrCircuitEntry 20 }
|
||
|
|
||
|
juniFrCircuitRowStatus OBJECT-TYPE
|
||
|
SYNTAX RowStatus
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This object is used to create a new row or modify or destroy an
|
||
|
existing row in the manner described in the definition of the RowStatus
|
||
|
textual convention. Writable objects in the table may be written in any
|
||
|
RowStatus state."
|
||
|
::= { juniFrCircuitEntry 21 }
|
||
|
|
||
|
juniFrCircuitSentFECNs OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of frames sent to the network indicating forward congestion
|
||
|
since the virtual circuit was created. This occurs when the remote DTE
|
||
|
sets the FECN flag, or when a switch in the network enqueues the frame
|
||
|
to a trunk whose transmission queue is congested."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.618-1991, Section 3.3.3"
|
||
|
::= { juniFrCircuitEntry 22 }
|
||
|
|
||
|
juniFrCircuitSentBECNs OBJECT-TYPE
|
||
|
SYNTAX Counter32
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Number of frames sent to the network indicating backward congestion
|
||
|
since the virtual circuit was created. This occurs when the remote DTE
|
||
|
sets the BECN flag, or when a switch in the network receives the frame
|
||
|
from a trunk whose transmission queue is congested."
|
||
|
REFERENCE
|
||
|
"American National Standard T1.618-1991, Section 3.3.4"
|
||
|
::= { juniFrCircuitEntry 23 }
|
||
|
|
||
|
|
||
|
-- /////////////////////////////////////////////////////////////////////////////
|
||
|
--
|
||
|
-- Frame Relay Subinterface Layer
|
||
|
--
|
||
|
-- This layer is managed with the following elements:
|
||
|
--
|
||
|
-- o NextIfIndex (generator for Frame Relay subinterface IfIndex selection)
|
||
|
-- o SubIf Table (creation/configuration/deletion of Frame Relay subinterfaces)
|
||
|
-- o SubIf Circuit Table (creation/deletion of circuits associated with
|
||
|
-- subinterfaces)
|
||
|
--
|
||
|
-- /////////////////////////////////////////////////////////////////////////////
|
||
|
--
|
||
|
-- IfIndex selection for creating new Frame Relay Subinterfaces
|
||
|
--
|
||
|
juniFrSubIfNextIfIndex OBJECT-TYPE
|
||
|
SYNTAX JuniNextIfIndex
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Coordinate ifIndex value allocation for entries in juniFrSubIfTable.
|
||
|
|
||
|
A GET of this object returns the next available ifIndex value to be used
|
||
|
to create an entry in the associated interface table; or zero, if no
|
||
|
valid ifIndex value is available. This object also returns a value of
|
||
|
zero when it is the lexicographic successor of a varbind presented in an
|
||
|
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
|
||
|
that ifIndex allocation is unintended.
|
||
|
|
||
|
Successive GETs will typically return different values, thus avoiding
|
||
|
collisions among cooperating management clients seeking to create table
|
||
|
entries simultaneously."
|
||
|
::= { juniFrSubIfLayer 1 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- The Frame Relay Subinterface Table
|
||
|
--
|
||
|
juniFrSubIfTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF JuniFrSubIfEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table contains entries for Frame Relay Subinterfaces present in
|
||
|
the system."
|
||
|
::= { juniFrSubIfLayer 2 }
|
||
|
|
||
|
juniFrSubIfEntry OBJECT-TYPE
|
||
|
SYNTAX JuniFrSubIfEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Each entry describes the characteristics of a Frame Relay Subinterface.
|
||
|
Creating/deleting entries in this table causes corresponding entries for
|
||
|
be created /deleted in ifTable/ifXTable/juniIfTable."
|
||
|
INDEX { juniFrSubIfIndex }
|
||
|
::= { juniFrSubIfTable 1 }
|
||
|
|
||
|
JuniFrSubIfEntry ::= SEQUENCE {
|
||
|
juniFrSubIfIndex InterfaceIndex,
|
||
|
juniFrSubIfRowStatus RowStatus,
|
||
|
juniFrSubIfLowerIfIndex InterfaceIndexOrZero,
|
||
|
juniFrSubIfId Integer32 }
|
||
|
|
||
|
juniFrSubIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndex
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ifIndex of the Frame Relay Subinterface. When creating entries in
|
||
|
this table, suitable values for this object are determined by reading
|
||
|
juniFrSubNextIfIndex."
|
||
|
::= { juniFrSubIfEntry 1 }
|
||
|
|
||
|
juniFrSubIfRowStatus OBJECT-TYPE
|
||
|
SYNTAX RowStatus
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Controls creation/deletion of entries in this table according to the
|
||
|
RowStatus textual convention, constrained to support the following
|
||
|
values only:
|
||
|
createAndGo
|
||
|
destroy
|
||
|
|
||
|
To create an entry in this table, the following entry objects MUST be
|
||
|
explicitly configured:
|
||
|
juniFrSubIfRowStatus
|
||
|
juniFrSubIfLowerIfIndex
|
||
|
|
||
|
In addition, when creating an entry the following conditions must hold:
|
||
|
|
||
|
A value for juniFrSubIfIndex must have been determined previously,
|
||
|
by reading juniFrSubIfNextIfIndex.
|
||
|
|
||
|
The interface identified by juniFrSubIfLowerIfIndex must exist, and
|
||
|
must be a Frame Relay interface.
|
||
|
|
||
|
A positive value configured for juniFrSubIfId must not already be
|
||
|
assigned to another subinterface layered onto the same underlying
|
||
|
Frame Relay interface.
|
||
|
|
||
|
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
|
||
|
destroyed as a result of creating/destroying an entry in this table."
|
||
|
::= { juniFrSubIfEntry 2 }
|
||
|
|
||
|
juniFrSubIfLowerIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndexOrZero
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ifIndex of a Frame Relay interface over which this Frame Relay
|
||
|
Subinterface is to be layered. A value of zero indicates no layering.
|
||
|
An implementation may choose to require that a nonzero value be
|
||
|
configured at entry creation."
|
||
|
::= { juniFrSubIfEntry 3 }
|
||
|
|
||
|
juniFrSubIfId OBJECT-TYPE
|
||
|
SYNTAX Integer32 (-1..2147483647)
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"An integer identifier for the Frame Relay subinterface, used in
|
||
|
conjunction with the command-line interface. It is provided here for
|
||
|
cross-reference purposes only.
|
||
|
|
||
|
The value must be unique among subinterfaces configured on the same
|
||
|
underlying Frame Relay interface.
|
||
|
|
||
|
If this object is not configured, or is configured with a value of -1, a
|
||
|
nonzero value will be allocated internally and can be retrieved from
|
||
|
this object after table entry creation has succeeded.
|
||
|
|
||
|
A value of zero for this object is reserved for future use."
|
||
|
DEFVAL { -1 }
|
||
|
::= { juniFrSubIfEntry 4 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- The Frame Relay Subinterface Circuit Table
|
||
|
--
|
||
|
juniFrSubIfCktTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF JuniFrSubIfCktEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table contains entries for Frame Relay circuits configured on
|
||
|
Frame Relay Subinterfaces present in the system.
|
||
|
|
||
|
An implementation may constrain the number of circuits permitted to be
|
||
|
configured per Frame Relay Subinterface; in particular, an
|
||
|
implementation may restrict each Frame Relay Subinterface to have a
|
||
|
single circuit.
|
||
|
|
||
|
Attributes in this entry can only be configured at entry creation, and
|
||
|
remain fixed for the lifetime of the entry."
|
||
|
::= { juniFrSubIfLayer 3 }
|
||
|
|
||
|
juniFrSubIfCktEntry OBJECT-TYPE
|
||
|
SYNTAX JuniFrSubIfCktEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Each entry describes the characteristics of a Frame Relay Subinterface
|
||
|
circuit."
|
||
|
INDEX { juniFrSubIfIndex,
|
||
|
juniFrSubIfCktDlci }
|
||
|
::= { juniFrSubIfCktTable 1 }
|
||
|
|
||
|
JuniFrSubIfCktEntry ::= SEQUENCE {
|
||
|
juniFrSubIfCktDlci DLCI,
|
||
|
juniFrSubIfCktRowStatus RowStatus }
|
||
|
|
||
|
juniFrSubIfCktDlci OBJECT-TYPE
|
||
|
SYNTAX DLCI
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The DLCI of the Frame Relay circuit used by this subinterface."
|
||
|
::= { juniFrSubIfCktEntry 1 }
|
||
|
|
||
|
juniFrSubIfCktRowStatus OBJECT-TYPE
|
||
|
SYNTAX RowStatus
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Controls creation/deletion of entries in this table according to the
|
||
|
RowStatus textual convention, constrained to support the following
|
||
|
values only:
|
||
|
createAndGo
|
||
|
destroy
|
||
|
|
||
|
To create an entry in this table, the following entry objects MUST be
|
||
|
explicitly configured:
|
||
|
juniFrSubIfCktRowStatus "
|
||
|
::= { juniFrSubIfCktEntry 2 }
|
||
|
|
||
|
|
||
|
-- /////////////////////////////////////////////////////////////////////////////
|
||
|
--
|
||
|
-- Multi-Link Frame Relay (MLFR)
|
||
|
--
|
||
|
-- This section defines objects used to manage the MLFR.
|
||
|
--
|
||
|
-- /////////////////////////////////////////////////////////////////////////////
|
||
|
--
|
||
|
-- The MLFR BundleTable
|
||
|
--
|
||
|
juniFrMlFrBundleTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF JuniFrMlFrBundleEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table contains entries for MLFR bundles present in the system."
|
||
|
::= { juniFrMlFr 1 }
|
||
|
|
||
|
juniFrMlFrBundleEntry OBJECT-TYPE
|
||
|
SYNTAX JuniFrMlFrBundleEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Each entry describes the characteristics of a Multilink bundle."
|
||
|
INDEX { juniFrMlFrBundleName }
|
||
|
::= { juniFrMlFrBundleTable 1 }
|
||
|
|
||
|
JuniFrMlFrBundleEntry ::= SEQUENCE {
|
||
|
juniFrMlFrBundleName JuniFrMlFrBundleName,
|
||
|
juniFrMlFrBundleRowStatus RowStatus }
|
||
|
|
||
|
juniFrMlFrBundleName OBJECT-TYPE
|
||
|
SYNTAX JuniFrMlFrBundleName
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The administrative name of the multilink bundle associated with this
|
||
|
Frame Relay major interface."
|
||
|
::= { juniFrMlFrBundleEntry 1 }
|
||
|
|
||
|
juniFrMlFrBundleRowStatus OBJECT-TYPE
|
||
|
SYNTAX RowStatus
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The rowStatus for this entry. The following sets are supported:
|
||
|
createAndGo(4),
|
||
|
destroy(6)
|
||
|
|
||
|
The following values can be read from this object:
|
||
|
active(1) "
|
||
|
::= { juniFrMlFrBundleEntry 2 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- IfIndex selection for creating new MLFR Link interfaces
|
||
|
-- in juniFrMlFrLinkConfigTable.
|
||
|
--
|
||
|
juniFrMlFrNextLinkIfIndex OBJECT-TYPE
|
||
|
SYNTAX JuniNextIfIndex
|
||
|
MAX-ACCESS read-only
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Coordinate ifIndex value allocation for entries in
|
||
|
juniFrMlFrLinkConfigTable.
|
||
|
|
||
|
A GET of this object returns the next available ifIndex value to be used
|
||
|
to create an entry in the associated interface table; or zero, if no
|
||
|
valid ifIndex value is available. This object also returns a value of
|
||
|
zero when it is the lexicographic successor of a varbind presented in an
|
||
|
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
|
||
|
that ifIndex allocation is unintended.
|
||
|
|
||
|
Successive GETs will typically return different values, thus avoiding
|
||
|
collisions among cooperating management clients seeking to create table
|
||
|
entries simultaneously."
|
||
|
::= { juniFrMlFr 2 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- The MLFR Link Configuration Table
|
||
|
--
|
||
|
juniFrMlFrLinkConfigTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF JuniFrMlFrLinkConfigEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table contains entries for FR link interfaces present in the
|
||
|
system to be added to the multilink bundles."
|
||
|
::= { juniFrMlFr 3 }
|
||
|
|
||
|
juniFrMlFrLinkConfigEntry OBJECT-TYPE
|
||
|
SYNTAX JuniFrMlFrLinkConfigEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Each entry describes the characteristics of FR link interface.
|
||
|
Creating/deleting entries in this table causes corresponding entries for
|
||
|
be created/deleted in ifTable/ifXTable/juniIfTable."
|
||
|
INDEX { juniFrMlFrLinkConfigIfIndex }
|
||
|
::= { juniFrMlFrLinkConfigTable 1 }
|
||
|
|
||
|
JuniFrMlFrLinkConfigEntry ::= SEQUENCE {
|
||
|
juniFrMlFrLinkConfigIfIndex InterfaceIndex,
|
||
|
juniFrMlFrLinkConfigLowerIfIndex InterfaceIndexOrZero,
|
||
|
juniFrMlFrLinkConfigRowStatus RowStatus }
|
||
|
|
||
|
juniFrMlFrLinkConfigIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndex
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ifIndex of the FR link interface. When creating entries in this
|
||
|
table, suitable values for this object are determined by reading
|
||
|
juniFrMlFrNextLinkIfIndex."
|
||
|
::= { juniFrMlFrLinkConfigEntry 1 }
|
||
|
|
||
|
juniFrMlFrLinkConfigLowerIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndexOrZero
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ifIndex of an interface over which this FR link interface is to be
|
||
|
layered. A value of zero indicates no layering. An implementation may
|
||
|
choose to require that a non-zero value be configured at entry
|
||
|
creation."
|
||
|
::= { juniFrMlFrLinkConfigEntry 2 }
|
||
|
|
||
|
juniFrMlFrLinkConfigRowStatus OBJECT-TYPE
|
||
|
SYNTAX RowStatus
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Controls creation/deletion of entries in this table according to the
|
||
|
RowStatus textual convention, constrained to support the following
|
||
|
values only:
|
||
|
createAndGo
|
||
|
destroy
|
||
|
|
||
|
To create an entry in this table, the following entry objects MUST be
|
||
|
explicitly configured:
|
||
|
juniFrMlFrLinkConfigRowStatus
|
||
|
juniFrMlFrLinkConfigLowerIfIndex
|
||
|
|
||
|
In addition, when creating an entry the following conditions must hold:
|
||
|
|
||
|
A value for juniFrMlFrLinkConfigIfIndex must have been determined
|
||
|
previously, by reading juniFrMlFrNextIfIndex.
|
||
|
|
||
|
The interface identified by juniFrMlFrLinkConfigLowerIfIndex must
|
||
|
exist.
|
||
|
|
||
|
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
|
||
|
destroyed as a result of creating/destroying an entry in this table."
|
||
|
::= { juniFrMlFrLinkConfigEntry 3 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- The MLFR Major interface Configuration Table
|
||
|
--
|
||
|
juniFrMlFrMajorConfigTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF JuniFrMlFrMajorConfigEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table contains entries for FR major interfaces present in the
|
||
|
system which are associated with multilink bundles."
|
||
|
::= { juniFrMlFr 4 }
|
||
|
|
||
|
juniFrMlFrMajorConfigEntry OBJECT-TYPE
|
||
|
SYNTAX JuniFrMlFrMajorConfigEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Each entry describes the characteristics of FR major interface which
|
||
|
have association with the MLFR bundles. Creating/deleting entries in
|
||
|
this table causes corresponding entries for be created/deleted in
|
||
|
ifTable/ifXTable/juniIfTable."
|
||
|
INDEX { juniFrMlFrMajorConfigIfIndex }
|
||
|
::= { juniFrMlFrMajorConfigTable 1 }
|
||
|
|
||
|
JuniFrMlFrMajorConfigEntry ::= SEQUENCE {
|
||
|
juniFrMlFrMajorConfigIfIndex InterfaceIndex,
|
||
|
juniFrMlFrMajorConfigLowerIfIndex InterfaceIndex,
|
||
|
juniFrMlFrMajorBundleName JuniFrMlFrBundleName,
|
||
|
juniFrMlFrMajorRowStatus RowStatus }
|
||
|
|
||
|
juniFrMlFrMajorConfigIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndex
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ifIndex of the FR Major interface. When creating entries in this
|
||
|
table, suitable values for this object are determined by reading already
|
||
|
created FR Major interface values.
|
||
|
|
||
|
Each multilink bundle will be associated with one FR major interface.
|
||
|
This association will be done at the creation of FR major interface
|
||
|
(juniFrDlcmiTable) specifying its lower interfce binding as FR link
|
||
|
ifIndex(juniFrMlFrLinkConfigTable) and the multilink bundle name."
|
||
|
::= { juniFrMlFrMajorConfigEntry 1 }
|
||
|
|
||
|
juniFrMlFrMajorConfigLowerIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndex
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ifIndex of a FR link interface over which this FR Major interface
|
||
|
is to be layered. On sets, the value of this object must equal on of
|
||
|
the previously created FR link interfaces created in the
|
||
|
juniFrMlFrLinkConfigTable. On gets, the value of this object is the
|
||
|
lexicographically least FR link interface in a potential bundle of FR
|
||
|
link interfaces."
|
||
|
::= { juniFrMlFrMajorConfigEntry 2 }
|
||
|
|
||
|
juniFrMlFrMajorBundleName OBJECT-TYPE
|
||
|
SYNTAX JuniFrMlFrBundleName
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The MLFR bundle name administratively assigned."
|
||
|
::= { juniFrMlFrMajorConfigEntry 3 }
|
||
|
|
||
|
juniFrMlFrMajorRowStatus OBJECT-TYPE
|
||
|
SYNTAX RowStatus
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Controls creation/deletion of entries in this table according to the
|
||
|
RowStatus textual convention, constrained to support the following
|
||
|
values only:
|
||
|
createAndGo
|
||
|
destroy
|
||
|
|
||
|
To create an entry in this table, the following entry objects MUST be
|
||
|
explicitly configured:
|
||
|
juniFrMlFrMajorConfigLowerIfIndex
|
||
|
juniFrMlFrMajorBundleName
|
||
|
juniFrMlFrMajorConfigRowStatus
|
||
|
|
||
|
In addition, when creating an entry the following conditions must hold:
|
||
|
|
||
|
The interface identified by juniFrMlFrMajorConfigIndex must exist by
|
||
|
a creation request to the juniFrDlcmiTable.
|
||
|
|
||
|
The interface identified by juniFrMlFrMajorConfigLowerIfIndex must
|
||
|
exist by a creation request to the juniFrMlFrLinkConfigTable.
|
||
|
|
||
|
The bundleName specified in juniFrMlFrMajorBundleName must have
|
||
|
been created first in the juniFrMlFrBundleTable.
|
||
|
|
||
|
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
|
||
|
destroyed as a result of creating/destroying an entry in this table. "
|
||
|
::= { juniFrMlFrMajorConfigEntry 4 }
|
||
|
|
||
|
|
||
|
--
|
||
|
-- The MLFR Link Bind Table
|
||
|
--
|
||
|
juniFrMlFrLinkBindTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF JuniFrMlFrLinkBindEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"This table contains entries for FR Link interfaces to FR major
|
||
|
interfaces bindings associated with multilink bundles."
|
||
|
::= { juniFrMlFr 5 }
|
||
|
|
||
|
juniFrMlFrLinkBindEntry OBJECT-TYPE
|
||
|
SYNTAX JuniFrMlFrLinkBindEntry
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Each entry describes the FR link interface to FR major interface
|
||
|
bindingsi associated with multilink bundles."
|
||
|
INDEX { juniFrMlFrBindMajorIfIndex,
|
||
|
juniFrMlFrBindLinkIfIndex }
|
||
|
::= { juniFrMlFrLinkBindTable 1 }
|
||
|
|
||
|
JuniFrMlFrLinkBindEntry ::= SEQUENCE {
|
||
|
juniFrMlFrBindMajorIfIndex InterfaceIndex,
|
||
|
juniFrMlFrBindLinkIfIndex InterfaceIndex,
|
||
|
juniFrMlFrBindRowStatus RowStatus }
|
||
|
|
||
|
juniFrMlFrBindMajorIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndex
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ifIndex of the FR major interface associated with multilink."
|
||
|
::= { juniFrMlFrLinkBindEntry 1 }
|
||
|
|
||
|
juniFrMlFrBindLinkIfIndex OBJECT-TYPE
|
||
|
SYNTAX InterfaceIndex
|
||
|
MAX-ACCESS not-accessible
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The ifIndex of a FR link interface bound by the FR major interface
|
||
|
defined by juniFrMlFrBindMajorIfIndex."
|
||
|
::= { juniFrMlFrLinkBindEntry 2 }
|
||
|
|
||
|
juniFrMlFrBindRowStatus OBJECT-TYPE
|
||
|
SYNTAX RowStatus
|
||
|
MAX-ACCESS read-create
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"Controls creation/deletion of entries in this table according to the
|
||
|
RowStatus textual convention, constrained to support the following
|
||
|
values only:
|
||
|
createAndGo
|
||
|
destroy
|
||
|
|
||
|
To create an entry in this table, the following entry objects MUST be
|
||
|
explicitly configured:
|
||
|
juniFrMlFrBindRowStatus
|
||
|
|
||
|
In addition, when creating an entry the following conditions must hold:
|
||
|
|
||
|
The interfaces identified by juniFrMlFrBindNetworkIfIndex and
|
||
|
juniFrMlFrBindLinkIfIndex must be created in the
|
||
|
juniFrMlFrMajorConfigTable and juniFrMlFrLinkConfigTable
|
||
|
respectively.
|
||
|
|
||
|
A MLFR bundle must be associated with the juniFrMlFrMajorIfIndex and
|
||
|
exist in the juniFrMibFrBundleTable.
|
||
|
|
||
|
A corresponding entry in ifStackTable is created/destroyed as a result
|
||
|
of creating/destroying an entry in this table.
|
||
|
Note: This table is read-only table for now. To add links to bundle
|
||
|
make use of juniFrMlFrMajorConfigTable."
|
||
|
::= { juniFrMlFrLinkBindEntry 3 }
|
||
|
|
||
|
|
||
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||
|
-- Notifications
|
||
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||
|
-- No notifications are defined in this MIB. Placeholders follow.
|
||
|
-- juniFrTrapControl OBJECT IDENTIFIER ::= { juniFrameRelayMIB 2 }
|
||
|
-- juniFrTraps OBJECT IDENTIFIER ::= { juniFrameRelayMIB 3 }
|
||
|
-- juniFrTrapPrefix OBJECT IDENTIFIER ::= { juniFrTraps 0 }
|
||
|
|
||
|
|
||
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||
|
-- Conformance information
|
||
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||
|
juniFrConformance OBJECT IDENTIFIER ::= { juniFrameRelayMIB 4 }
|
||
|
juniFrCompliances OBJECT IDENTIFIER ::= { juniFrConformance 1 }
|
||
|
juniFrGroups OBJECT IDENTIFIER ::= { juniFrConformance 2 }
|
||
|
|
||
|
--
|
||
|
-- compliance statements
|
||
|
--
|
||
|
juniFrCompliance MODULE-COMPLIANCE
|
||
|
STATUS obsolete
|
||
|
DESCRIPTION
|
||
|
"Obsolete compliance statement for entities that implement the Juniper
|
||
|
Frame Relay MIB. This statement became obsolete when multi-link frame
|
||
|
relay support was added."
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS {
|
||
|
juniFrGroup,
|
||
|
juniFrSubIfGroup }
|
||
|
::= { juniFrCompliances 1 } -- JUNOSe 1.0
|
||
|
|
||
|
juniFrCompliance2 MODULE-COMPLIANCE
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"The compliance statement for entities that implement the Juniper Frame
|
||
|
Relay MIB."
|
||
|
MODULE -- this module
|
||
|
MANDATORY-GROUPS {
|
||
|
juniFrGroup2,
|
||
|
juniFrSubIfGroup,
|
||
|
juniFrMlFrGroup }
|
||
|
::= { juniFrCompliances 2 } -- JUNOSe 5.0
|
||
|
|
||
|
|
||
|
--
|
||
|
-- units of conformance
|
||
|
--
|
||
|
juniFrGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
juniFrNextIfIndex,
|
||
|
|
||
|
juniFrDlcmiIfIndex,
|
||
|
juniFrDlcmiState,
|
||
|
juniFrDlcmiAddress,
|
||
|
juniFrDlcmiAddressLen,
|
||
|
juniFrDlcmiPollingInterval,
|
||
|
juniFrDlcmiFullEnquiryInterval,
|
||
|
juniFrDlcmiErrorThreshold,
|
||
|
juniFrDlcmiMonitoredEvents,
|
||
|
juniFrDlcmiMaxSupportedVCs,
|
||
|
juniFrDlcmiMulticast,
|
||
|
juniFrDlcmiStatus,
|
||
|
juniFrDlcmiRowStatus,
|
||
|
juniFrDlcmiLowerIfIndex,
|
||
|
juniFrDlcmiRole,
|
||
|
juniFrDlcmiDcePollingInterval,
|
||
|
juniFrDlcmiDceErrorThreshold,
|
||
|
juniFrDlcmiDceMonitoredEvents,
|
||
|
|
||
|
juniFrDlcmiStatsDteEnquiries,
|
||
|
juniFrDlcmiStatsDteFullEnquiries,
|
||
|
juniFrDlcmiStatsDteEnquiryResponses,
|
||
|
juniFrDlcmiStatsDteFullEnquiryResponses,
|
||
|
juniFrDlcmiStatsDteAsyncUpdates,
|
||
|
juniFrDlcmiStatsDteUnknownRxMessages,
|
||
|
juniFrDlcmiStatsDteLossOfSequences,
|
||
|
juniFrDlcmiStatsDteNoResponseTimeouts,
|
||
|
juniFrDlcmiStatsDceEnquiries,
|
||
|
juniFrDlcmiStatsDceFullEnquiries,
|
||
|
juniFrDlcmiStatsDceEnquiryResponses,
|
||
|
juniFrDlcmiStatsDceFullEnquiryResponses,
|
||
|
juniFrDlcmiStatsDceAsyncUpdates,
|
||
|
juniFrDlcmiStatsDceUnknownRxMessages,
|
||
|
juniFrDlcmiStatsDceLossOfSequences,
|
||
|
juniFrDlcmiStatsDceNoResponseTimeouts,
|
||
|
juniFrDlcmiStatsDiscontinuityTime,
|
||
|
|
||
|
juniFrCircuitState,
|
||
|
juniFrCircuitReceivedFECNs,
|
||
|
juniFrCircuitReceivedBECNs,
|
||
|
juniFrCircuitSentFrames,
|
||
|
juniFrCircuitSentOctets,
|
||
|
juniFrCircuitReceivedFrames,
|
||
|
juniFrCircuitReceivedOctets,
|
||
|
juniFrCircuitCreationTime,
|
||
|
juniFrCircuitLastTimeChange,
|
||
|
juniFrCircuitCommittedBurst,
|
||
|
juniFrCircuitExcessBurst,
|
||
|
juniFrCircuitThroughput,
|
||
|
juniFrCircuitMulticast,
|
||
|
juniFrCircuitType,
|
||
|
juniFrCircuitDiscards,
|
||
|
juniFrCircuitReceivedDEs,
|
||
|
juniFrCircuitSentDEs,
|
||
|
juniFrCircuitLogicalIfIndex,
|
||
|
juniFrCircuitRowStatus,
|
||
|
juniFrCircuitSentFECNs,
|
||
|
juniFrCircuitSentBECNs }
|
||
|
STATUS obsolete
|
||
|
DESCRIPTION
|
||
|
"Obsolete collection of objects providing management of Frame Relay
|
||
|
interfaces in a Juniper product. This group became obsolete when
|
||
|
multi-link frame relay support was added."
|
||
|
::= { juniFrGroups 1 }
|
||
|
|
||
|
juniFrSubIfGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
juniFrSubIfNextIfIndex,
|
||
|
|
||
|
juniFrSubIfRowStatus,
|
||
|
juniFrSubIfLowerIfIndex,
|
||
|
juniFrSubIfId,
|
||
|
|
||
|
juniFrSubIfCktRowStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of objects providing management of Frame Relay
|
||
|
subinterfaces in a Juniper product."
|
||
|
::= { juniFrGroups 2 }
|
||
|
|
||
|
juniFrGroup2 OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
juniFrNextIfIndex,
|
||
|
|
||
|
juniFrDlcmiIfIndex,
|
||
|
juniFrDlcmiState,
|
||
|
juniFrDlcmiAddress,
|
||
|
juniFrDlcmiAddressLen,
|
||
|
juniFrDlcmiPollingInterval,
|
||
|
juniFrDlcmiFullEnquiryInterval,
|
||
|
juniFrDlcmiErrorThreshold,
|
||
|
juniFrDlcmiMonitoredEvents,
|
||
|
juniFrDlcmiMaxSupportedVCs,
|
||
|
juniFrDlcmiMulticast,
|
||
|
juniFrDlcmiStatus,
|
||
|
juniFrDlcmiRowStatus,
|
||
|
juniFrDlcmiLowerIfIndex,
|
||
|
juniFrDlcmiRole,
|
||
|
juniFrDlcmiDcePollingInterval,
|
||
|
juniFrDlcmiDceErrorThreshold,
|
||
|
juniFrDlcmiDceMonitoredEvents,
|
||
|
juniFrDlcmiMultilinkFrBundleName,
|
||
|
|
||
|
juniFrDlcmiStatsDteEnquiries,
|
||
|
juniFrDlcmiStatsDteFullEnquiries,
|
||
|
juniFrDlcmiStatsDteEnquiryResponses,
|
||
|
juniFrDlcmiStatsDteFullEnquiryResponses,
|
||
|
juniFrDlcmiStatsDteAsyncUpdates,
|
||
|
juniFrDlcmiStatsDteUnknownRxMessages,
|
||
|
juniFrDlcmiStatsDteLossOfSequences,
|
||
|
juniFrDlcmiStatsDteNoResponseTimeouts,
|
||
|
juniFrDlcmiStatsDceEnquiries,
|
||
|
juniFrDlcmiStatsDceFullEnquiries,
|
||
|
juniFrDlcmiStatsDceEnquiryResponses,
|
||
|
juniFrDlcmiStatsDceFullEnquiryResponses,
|
||
|
juniFrDlcmiStatsDceAsyncUpdates,
|
||
|
juniFrDlcmiStatsDceUnknownRxMessages,
|
||
|
juniFrDlcmiStatsDceLossOfSequences,
|
||
|
juniFrDlcmiStatsDceNoResponseTimeouts,
|
||
|
juniFrDlcmiStatsDiscontinuityTime,
|
||
|
|
||
|
juniFrCircuitState,
|
||
|
juniFrCircuitReceivedFECNs,
|
||
|
juniFrCircuitReceivedBECNs,
|
||
|
juniFrCircuitSentFrames,
|
||
|
juniFrCircuitSentOctets,
|
||
|
juniFrCircuitReceivedFrames,
|
||
|
juniFrCircuitReceivedOctets,
|
||
|
juniFrCircuitCreationTime,
|
||
|
juniFrCircuitLastTimeChange,
|
||
|
juniFrCircuitCommittedBurst,
|
||
|
juniFrCircuitExcessBurst,
|
||
|
juniFrCircuitThroughput,
|
||
|
juniFrCircuitMulticast,
|
||
|
juniFrCircuitType,
|
||
|
juniFrCircuitDiscards,
|
||
|
juniFrCircuitReceivedDEs,
|
||
|
juniFrCircuitSentDEs,
|
||
|
juniFrCircuitLogicalIfIndex,
|
||
|
juniFrCircuitRowStatus,
|
||
|
juniFrCircuitSentFECNs,
|
||
|
juniFrCircuitSentBECNs }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of objects providing management of Frame Relay interfaces
|
||
|
in a Juniper product."
|
||
|
::= { juniFrGroups 3 }
|
||
|
|
||
|
juniFrMlFrGroup OBJECT-GROUP
|
||
|
OBJECTS {
|
||
|
juniFrMlFrBundleRowStatus,
|
||
|
|
||
|
juniFrMlFrNextLinkIfIndex,
|
||
|
|
||
|
juniFrMlFrLinkConfigLowerIfIndex,
|
||
|
juniFrMlFrLinkConfigRowStatus,
|
||
|
|
||
|
juniFrMlFrMajorConfigLowerIfIndex,
|
||
|
juniFrMlFrMajorBundleName,
|
||
|
juniFrMlFrMajorRowStatus,
|
||
|
|
||
|
juniFrMlFrBindRowStatus }
|
||
|
STATUS current
|
||
|
DESCRIPTION
|
||
|
"A collection of objects providing management of Multilink Frame Relay
|
||
|
in a Juniper product."
|
||
|
::= { juniFrGroups 4 }
|
||
|
|
||
|
END
|