mibs/MIBS/junose/Juniper-System-MIB

3623 lines
150 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- *****************************************************************************
-- Juniper-System-MIB
--
-- Juniper Networks Enterprise MIB
-- E-series System MIB
--
-- Copyright (c) 2002-2008 Juniper Networks, Inc. All Rights Reserved.
-- *****************************************************************************
Juniper-System-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32,
Gauge32, TimeTicks
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString, TruthValue, DateAndTime
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
PhysicalIndex, entPhysicalDescr
FROM ENTITY-MIB
KBytes
FROM HOST-RESOURCES-MIB
InterfaceIndexOrZero
FROM IF-MIB
juniMibs
FROM Juniper-MIBs
JuniEnable, JuniTimeFilter
FROM Juniper-TC;
juniSystemMIB MODULE-IDENTITY
LAST-UPDATED "200806111101Z" -- 11-Jun-08 07:01 AM EDT
ORGANIZATION "Juniper Networks, Inc."
CONTACT-INFO
" Juniper Networks, Inc.
Postal: 10 Technology Park Drive
Westford, MA 01886-3146
USA
Tel: +1 978 589 5800
Email: mib@Juniper.net"
DESCRIPTION
"The MIB objects for managing a Juniper E-series (JUNOSe) system. This
MIB complements the ENTITY-MIB.entPhysicalTable by providing the
system's physical information in a format that is more user friendly and
provides additional elements not found in the Entity MIB, including
state information, parameters for configuring the system and additional
notifications.
There are two families of E-series hardware systems supported by this
MIB:
ERX - first generation E-series systems
ES2 - second generation E-series systems "
-- Revision History
REVISION "200806111101Z" -- 11-Jun-08 07:01 AM EDT - JUNOSe 10.0
DESCRIPTION
"Added es2Lm10s support."
REVISION "200805051241Z" -- 05-May-08 08:41 AM EDT - JUNOSe 9.2
DESCRIPTION
"Add ISSU Support for ERX-1440."
REVISION "200705071012Z" -- 07-May-07 06:12 AM EDT - JUNOSe 9.0
DESCRIPTION
"Add ISSU support."
REVISION "200612182125Z" -- 18-Dec-06 04:25 PM EST - JUNOSe 8.3
DESCRIPTION
"Add LM10 Access Support."
REVISION "200611240913Z" -- 24-Nov-06 04:13 AM EST - JUNOSe 8.2
DESCRIPTION
"Add suppot for ES2 primary modules SRP-120 and SFM-120 for E120."
REVISION "200605180831Z" -- 18-May-06 02:01 PM EST - JUNOSe 8.0
DESCRIPTION
"Add last 5 seconds, 1 minute and 5 minutes avergae CPU utilzation
support."
REVISION "200601061817Z" -- 06-Jan-06 01:17 PM EST - JUNOSe main
DESCRIPTION
"Add LM10 Access Support."
REVISION "200512160721Z" -- 16-Dec-05 12:51 PM EST - JUNOSe main
DESCRIPTION
"Changed maximum value of juniSystemHighMemUtilThreshold from 100 to 99
and maximum value of juniSystemAbatedMemUtilThreshold from 99 to 98."
REVISION "200511182230Z" -- 18-Nov-05 05:30 PM EST - JUNOSe 7.3
DESCRIPTION
"Add CPU utilization statitics table support."
REVISION "200509151414Z" -- 15-Sep-05 10:14 AM EDT - JUNOSe 7.2
DESCRIPTION
"Add LM10 Uplink Support."
REVISION "200508191748Z" -- 29-Jul-05 01:48 PM EDT - JUNOSe main
DESCRIPTION
"Add Ge8 support."
REVISION "200507291748Z" -- 29-Jul-05 01:48 PM EDT - JUNOSe 7.0.1
DESCRIPTION
"conform to REX Naming Document, renamed various ES2 module types
and deleted ones that didn't belong."
REVISION "200505181810Z" -- 18-May-05 02:10 PM EDT - JUNOSe 7.0.0
DESCRIPTION
"Updated JuniSystemModuleType TC and created JuniSystemSlotLevel TC."
REVISION "200505041810Z" -- 04-May-05 02:10 PM EDT - JUNOSe 7.0.0
DESCRIPTION
"Added GE-HDE support."
REVISION "200501311813Z" -- 31-Jan-05 02:13 PM EDT - JUNOSe 5.1.5
DESCRIPTION
"Added KByte memory capacity object to notification."
REVISION "200412311013Z" -- 31-Dec-04 05:13 AM EST - JUNOSe main
DESCRIPTION
"Updated for second generation E-series router."
REVISION "200412291010Z" -- 29-Dec-04 05:10 AM EST - JUNOSe 6.1
DESCRIPTION
"Updated SystemTimingSelector TC and related timing objects."
REVISION "200405251813Z" -- 25-May-04 02:13 PM EDT - JUNOSe 6.1
DESCRIPTION
"Added support for the Fe8 FX IOA."
REVISION "200401072246Z" -- 07-Jan-04 05:46 PM EST - JUNOSe 6.0
DESCRIPTION
"Added support for the second generation E-series hardware
architecture."
REVISION "200311242059Z" -- 24-Nov-03 03:59 PM EST - JUNOSe 5.3
DESCRIPTION
"Added Hybrid Primary Module and Hybrid IOA modules.
Added GE2 Primary Module and GE2 IOA module."
REVISION "200311241939Z" -- 24-Nov-03 02:39 PM EST - JUNOSe 5.2
DESCRIPTION
"Added resource utilization notification enable/disable.
Added KByte memory capacilty object."
REVISION "200307221410Z" -- 22-Jul-03 10:10 AM EDT - JUNOSe 5.1
DESCRIPTION
"Added ERX-310 support."
REVISION "200301272122Z" -- 27-Jan-03 04:22 PM EST - JUNOSe 5.0
DESCRIPTION
"Replaced Unisphere names with Juniper names.
Added resource utilization notification support."
REVISION "200210172101Z" -- 17-Oct-02 05:01 PM EDT - JUNOSe 4.1
DESCRIPTION
"Initial version of this MIB module."
::= { juniMibs 2 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Textual conventions
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
JuniSystemModuleType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The 'personality' type of a module found in an E-series system. Some
primary modules (e.g., line cards) have only one personality; that is
they only accept one personality of other level modules (e.g. I/O
adapters) in the same slot and are always configured in the same way.
Other modules are multi-personality and will behave differently
depending on the other level modules they are operating with, and
therefore cannot be configured without knowing the other level module
type(s). Type values in this table include both. Types that are
multi-personality are noted by [MP] and types that are personality-only
are noted by [PO]. Use the ENTITY-MIB to deretmine the actual hardware
type of a module with personality-only type.
unknown Unknown module type
ERX primary modules:
erxSrp ERX Switch/Route Processor
erxCt3 ERX 3 port Channelized T3
erxOc3 ERX 2 port OC3 SONET/SDH
erxUt3Atm ERX 3 port Unchannelized T3 ATM
erxUt3Frame ERX 3 port Unchannelized T3 Frame
erxUe3Atm ERX 3 port Unchannelized E3 ATM
erxUe3Frame ERX 3 port Uncahnnelized E3 Frame
erxCe1 ERX 20 port Channelized E1
erxCt1 ERX 24 port Channelized T1
erxDpfe ERX 2 port Fast Ethernet
erxOc12Pos ERX 1 port OC12 POS
erxOc12Atm ERX 1 port OC12 ATM
erxOc3Pos ERX 4 port OC3 POS
erxOc3Atm ERX 4 port OC3 ATM
erxGe ERX 1 port Gigabit Ethernet [PO]
erxFe8 ERX 8 port Fast Ethernet [PO]
erxOc3oc12Pos ERX OC3/OC12 POS [MP]
erxOc3oc12Atm ERX OC3/OC12 ATM [MP]
erxCoc3oc12 ERX Channelized OC3/OC12 [MP]
erxCoc3 ERX 4 port Channelized OC3 [PO]
erxCoc12 ERX 1 port Channelized OC12 [PO]
erxOc12Server ERX 1 port OC12 Tunnel Server
erxHssi ERX 3 port High Speed Serial Interface
erxGeFe ERX Gigabit Ethernet / Fast Ethernet [MP]
erxCt3P12 ERX 12 port Channelized T3
erxV35 ERX 16 port X.21/V.35
erxUt3f12 ERX 12 port Unchannelized T3 Frame [PO]
erxUe3f12 ERX 12 port Unchannelized E3 Frame [PO]
erxCoc12F3 ERX 1 port OC12 channelized to T3/E3 [PO]
erxCoc3F3 ERX 4 port OC3 channelized to T3/E3 [PO]
erxCocxF3 ERX OC3/OC12 channelized to T3/E3 [MP]
erxVts ERX Virtual Tunnel Server
erxOc48 ERX 1 port OC48 SONET/SDH
erxUt3Atm4 ERX 4 port Unchannelized T3/E3 ATM [PO]
erxHybrid ERX ATM / POS / Gigabit Ethernet Hybrid [MP]
erxOc3AtmGe ERX 2 port OC3 ATM 1 port Gigabit Ethernet [PO]
erxOc3AtmPos ERX 2 port OC3 ATM 2 port OC3 POS [PO]
erxGe2 ERX 2 port Gigabit Ethernet
erxGeHde ERX 2/8 port Gigabit Ethernet
ERX I/O adapter (IOA) modules:
erxSrpIoa ERX Switch/Route Processor IOA
erxCt1Ioa ERX 24 port channelized T1/J1 IOA
erxCe1Ioa ERX 20 port channelized E1 IOA
erxCe1TIoa ERX 20 port channelized E1 Telco IOA
erxCt3Ioa ERX 3 port channelized T3/E3 IOA
erxE3Ioa ERX 3 port E3 IOA
erxOc3Mm2Ioa ERX 2 port OC3 multi-mode IOA
erxOc3Sm2Ioa ERX 2 port OC3 single-mode IOA
erxOc3Mm4Ioa ERX 4 port OC3 multi-mode IOA
erxOc3SmIr4Ioa ERX 4 port OC3 single-mode
intermediate-reach IOA
erxOc3SmLr4Ioa ERX 4 port OC3 single-mode long-reach IOA
erxCOc3Mm4Ioa ERX 4 port channelized OC3 multi-mode IOA
erxCOc3SmIr4Ioa ERX 4 port channelized OC3 single-mode
intermediate-reach IOA
erxCOc3SmLr4Ioa ERX 4 port channelized OC3 single-mode
long-reach IOA
erxOc12Mm1Ioa ERX 1 port OC12 multi-mode IOA
erxOc12SmIr1Ioa ERX 1 port OC12 single-mode
intermediate-reach IOA
erxOc12SmLr1Ioa ERX 1 port OC12 single-mode long-reach IOA
erxCOc12Mm1Ioa ERX 1 port channelized OC12 multi-mode IOA
erxCOc12SmIr1Ioa ERX 1 port channelized OC12 single-mode
intermediate-reach IOA
erxCOc12SmLr1Ioa ERX 1 port channelized OC12 single-mode
long-reach IOA
erxFe2Ioa ERX 2 port 10/100 Fast Ethernet IOA
erxFe8Ioa ERX 8 port 10/100 Fast Ethernet IOA
erxGeMm1Ioa ERX 1 port Gigabit Ethernet multi-mode IOA
erxGeSm1Ioa ERX 1 port Gigabit Ethernet single-mode
IOA
erxHssiIoa ERX 3 port High Speed Serial Interface IOA
erxCt3P12Ioa ERX 12 port channelized and unchannelized
T3 IOA
erxV35Ioa ERX 16 port X2.1/V3.5 IOA
erxGeSfpIoa ERX 1 port Gigabit Ethernet SFP IOA
erxUe3P12Ioa ERX 12 port unchannelized E3 IOA
erxT3Atm4Ioa ERX 4 port T3 ATM IOA
erxCOc12Mm1ApsIoa ERX 1 port channelized OC12 multi-mode APS
(1+1) IOA
erxCOc12SmIr1ApsIoa ERX 1 port channelized OC12 single-mode
intermediate-reach APS (1+1) IOA
erxCOc12SmLr1ApsIoa ERX 1 port channelized OC12 single-mode
long-reach APS (1+1) IOA
erxOc12Mm1ApsIoa ERX 1 port OC12 multi-mode APS (1+1) IOA
erxOc12SmIr1ApsIoa ERX 1 port OC12 single-mode
intermediate-reach APS (1+1) IOA
erxOc12SmLr1ApsIoa ERX 1 port OC12 single-mode long-reach APS
(1+1) IOA
erxCOc12AtmPosMm1Ioa ERX 1 port channelized OC12 multi-mode
ATM/POS IOA
erxCOc12AtmPosSmIr1Ioa ERX 1 port channelized OC12 single-mode
intermediate-reach ATM/POS IOA
erxCOc12AtmPosSmLr1Ioa ERX 1 port channelized OC12 single-mode
long-reach ATM/POS IOA
erxCOc12AtmPosMm1ApsIoa ERX 1 port channelized OC12 multi-mode
ATM/POS APS (1+1) IOA
erxCOc12AtmPosSmIr1ApsIoa ERX 1 port channelized OC12 single-mode
intermediate-reach ATM/POS APS (1+1) IOA
erxCOc12AtmPosSmLr1ApsIoa ERX 1 port channelized OC12 single-mode
long-reach ATM/POS APS (1+1) IOA
erxT1E1RedundantIoa ERX T1/E1 redundant midplane spare IOA
erxT3E3RedundantIoa ERX T3/E3 redundant midplane spare IOA
erxCt3RedundantIoa ERX channelized T3 redundant midplane
spare IOA
erxOcxRedundantIoa ERX OC3/OC12 redundant midplane spare IOA
erxCOcxRedundantIoa ERX channelized OC3/OC12 redundant
midplane spare IOA
erxOc3Mm4ApsIoa ERX 4 port OC3 multi-mode APS (1+1) IOA
erxOc3SmIr4ApsIoa ERX 4 port OC3 single-mode
intermediate-reach APS (1+1) IOA
erxOc3SmLr4ApsIoa ERX 4 port OC3 single-mode long-reach APS
(1+1) IOA
erxOc48Ioa ERX 1 port OC48/STM16 IOA
erxOc3Atm2Ge1Ioa ERX 2 port OC3 ATM 1 port GE IOA
erxOc3Atm2Pos2Ioa ERX 2 port OC3 ATM 2 port OC3 POS IOA
erxGe2Ioa ERX 2 port Gigabit Ethernet IOA
erxFe8FxIoa ERX 8 port 100 Fast Ethernet SFP IOA
erxGe8Ioa ERX 8 port Gigabit Ethernet IOA
ES2 primary modules:
e320Srp100 ES2 100Gb System Route Processor with integrated
fabric slice
e320Sfm100 ES2 100Gb Switch Fabric Slice
es2Lm4 ES2 4Gb (series 1) Line Module(LM).
es2Lm10Uplink ES2 10Gb (series 2) Uplink Line Module(LM).
es2Lm10 ES2 10Gb (series 3) Line Module(LM).
e320Srp320 ES2 320Gb System Route Processor with integrated
fabric slice
e320Sfm320 ES2 320Gb Switch Fabric Slice
es2Lm10s ES2 10Gb (series 4) Line Module(LM).
ES2 I/O adapter (IOA) modules:
e320SrpIoa ES2 system resource processor IOA
es2Ge4S1Ioa ES2 4 port Gigabit Ethernet S1 IOA
es2Oc48Stm16PosS1Ioa ES2 OC48/STM16 POS S1 IOA
es2ServiceS1Ioa ES2 Service S1 IOA
es2Oc3Stm1x8AtmS1Ioa ES2 OC3/STM1-8 ATM S1 IOA
es2RedundancyS1Ioa ES2 Redundancy S1 IOA
es2Oc12Stm4x2PosS1Ioa ES2 OC12/STM4-2 POS S1 IOA
es2Oc12Stm4x2AtmS1Ioa ES2 OC12/STM4-2 ATM S1 IOA
es2dash10GeS1Ioa ES2 10GE-1 SR S1 IOA
es2Ge8S1Ioa ES2 8 port Gigabit Ethernet S1 IOA
es2dash10GePrS2Ioa ES2 10GE-1 Port Redundancy S2 IOA
es2Ge20S2Ioa ES2 20 port Gigabit Ethernet S2 IOA
ES2 primary modules for E120:
e120Srp120 ES2 120Gb System Route Processor with integrated
fabric slice
e120Sfm120 ES2 120Gb Switch Fabric Slice"
SYNTAX INTEGER {
unknown(0),
-- ERX primary module types
erxSrp(1),
erxCt3(2),
erxOc3(3),
erxUt3Atm(4),
erxUt3Frame(5),
erxUe3Atm(6),
erxUe3Frame(7),
erxCe1(8),
erxCt1(9),
erxDpfe(10),
erxOc12Pos(11),
erxOc12Atm(12),
erxOc3Pos(13),
erxOc3Atm(14),
erxGe(15),
erxFe8(16),
erxOc3oc12Pos(17),
erxOc3oc12Atm(18),
erxCoc3oc12(19),
erxCoc3(20),
erxCoc12(21),
erxOc12Server(22),
erxHssi(23),
erxGeFe(24),
erxCt3P12(25),
erxV35(26),
erxUt3f12(27),
erxUe3f12(28),
erxCoc12F3(29),
erxCoc3F3(30),
erxCocxF3(31),
erxVts(32),
erxOc48(33),
erxUt3Atm4(34),
erxHybrid(35),
erxOc3AtmGe(36),
erxOc3AtmPos(37),
erxGe2(38),
erxGeHde(39),
-- ERX I/O adapter (IOA) module types
erxSrpIoa(1024),
erxCt1Ioa(1025),
erxCe1Ioa(1026),
erxCe1TIoa(1027),
erxCt3Ioa(1028),
erxE3Ioa(1029),
erxOc3Mm2Ioa(1030),
erxOc3Sm2Ioa(1031),
erxOc3Mm4Ioa(1032),
erxOc3SmIr4Ioa(1033),
erxOc3SmLr4Ioa(1034),
erxCOc3Mm4Ioa(1035),
erxCOc3SmIr4Ioa(1036),
erxCOc3SmLr4Ioa(1037),
erxOc12Mm1Ioa(1038),
erxOc12SmIr1Ioa(1039),
erxOc12SmLr1Ioa(1040),
erxCOc12Mm1Ioa(1041),
erxCOc12SmIr1Ioa(1042),
erxCOc12SmLr1Ioa(1043),
erxFe2Ioa(1044),
erxFe8Ioa(1045),
erxGeMm1Ioa(1046),
erxGeSm1Ioa(1047),
erxHssiIoa(1048),
erxCt3P12Ioa(1049),
erxV35Ioa(1050),
erxGeSfpIoa(1051),
erxUe3P12Ioa(1052),
erxT3Atm4Ioa(1053),
erxCOc12Mm1ApsIoa(1054),
erxCOc12SmIr1ApsIoa(1055),
erxCOc12SmLr1ApsIoa(1056),
erxOc12Mm1ApsIoa(1057),
erxOc12SmIr1ApsIoa(1058),
erxOc12SmLr1ApsIoa(1059),
erxCOc12AtmPosMm1Ioa(1060),
erxCOc12AtmPosSmIr1Ioa(1061),
erxCOc12AtmPosSmLr1Ioa(1062),
erxCOc12AtmPosMm1ApsIoa(1063),
erxCOc12AtmPosSmIr1ApsIoa(1064),
erxCOc12AtmPosSmLr1ApsIoa(1065),
erxT1E1RedundantIoa(1066),
erxT3E3RedundantIoa(1067),
erxCt3RedundantIoa(1068),
erxOcxRedundantIoa(1069),
erxCOcxRedundantIoa(1070),
erxOc3Mm4ApsIoa(1071),
erxOc3SmIr4ApsIoa(1072),
erxOc3SmLr4ApsIoa(1073),
erxOc48Ioa(1074),
erxOc3Atm2Ge1Ioa(1075),
erxOc3Atm2Pos2Ioa(1076),
erxGe2Ioa(1077),
erxFe8FxIoa(1078),
erxGe8Ioa(1079),
-- ES2 primary module types
e320Srp100(2048),
e320Sfm100(2049),
es2Lm4(2050),
es2Lm10Uplink(2051),
es2Lm10(2052),
e320Srp320(2053),
e320Sfm320(2054),
es2Lm10s(2055),
-- ES2 I/O adapter (IOA) module types
e320SrpIoa(3072),
es2Ge4S1Ioa(3073),
es2Oc48Stm16PosS1Ioa(3074),
es2ServiceS1Ioa(3075),
es2Oc3Stm1x8AtmS1Ioa(3076),
es2RedundancyS1Ioa(3077),
es2Oc12Stm4x2PosS1Ioa(3078),
es2Oc12Stm4x2AtmS1Ioa(3079),
es2dash10GeS1Ioa(3080),
es2Ge8S1Ioa(3081),
es2dash10GePrS2Ioa(3082),
es2Ge20S2Ioa(3083) ,
-- ES2 primary module types for E120
e120Srp120(4096),
e120Sfm120(4097) }
JuniSystemSlotLevel ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The relative position of a module or sub-module 'container' within a
slot. The upper limit of valid values is juniSystemMaxModulesPerSlot.
A module or sub-module in the lowest numbered level for a particular
slot is considered to be the 'primary' module for that slot.
For the first generation E-series (ERX) platform family:
level 1 - SRP or line card module
level 2 - I/O adapter module
For the second generation E-series platform family:
level 1 - Forwarding module or SRP sub-module
level 2 - Switch fabric slice (SFS) sub-module or module
level 3 - Bay 0 I/O adapter
level 4 - Bay 1 I/O adapter "
SYNTAX Integer32 (1..4)
JuniSystemSlotType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The type of 'container' for holding a module or sub-module found in an
E-series chassis.
The slot type may be for a 'sub-module' where there are multiple logical
functions on a single hardware module. For example, the second
generation SRP hardware module (slot 6 or 7 on an E320) contains both a
System Resource Processor (SRP) sub-module (level 1 position) and a
Switch Fabric Slice (SFS) sub-module (level 2 position).
noSlot The slot does not exist
ERX system slot types:
erxSrpSlot ERX switch/route processor module slot
erxLcmSlot ERX line card module slot
erxSrpIoaSlot ERX switch/route processor I/O adapter slot
erxLcIoaSlot ERX line card I/O adapter slot
Second generation E-series (ES2) system slot types:
es2SrpSlot ES2 system resource processor sub-module slot
es2SfsSlot ES2 switch fabric module or sub-module slot
es2FmSlot ES2 forwarding module slot
es2SrpIoaSlot ES2 system resource processor I/O adapter slot
es2FIoaSlot ES2 forwarding I/O adapter slot "
SYNTAX INTEGER {
noSlot(0),
-- ERX system slot types
erxSrpSlot(1),
erxLcmSlot(2),
erxSrpIoaSlot(3),
erxLcIoaSlot(4),
-- ES2 system slot types
es2SrpSlot(16),
es2SfsSlot(17),
es2FmSlot(18),
es2SrpIoaSlot(19),
es2FIoaSlot(20) }
JuniSystemTimingSelector ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The system timing selector.
primary - the primary timing selector
secondary - the secondary timing selector
tertiary - the tertiary timing selector
error - the error in timing selector"
SYNTAX INTEGER {
primary(1),
secondary(2),
tertiary(3),
error(4)}
JuniSystemLocationType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The location information class that is used to understand the encoding
of the associated location instance information. An object with this
syntax is always paired with an object that uses the JuniSystemLocation
syntax.
system - all resources on the system
slot - all resources associated with a particular slot "
SYNTAX INTEGER {
system(1),
slot(2) }
JuniSystemLocation ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The location instance information that is encoded according to the
rules for the associated location information class. An object with
this syntax is always paired with an object that uses the
JuniSystemLocationType syntax.
system - a zero length string: { ''H }
slot - a single octet (see juniSystemSlotNumber) "
SYNTAX OCTET STRING (SIZE(0..16))
JuniSystemTaskName ::= TEXTUAL-CONVENTION
DISPLAY-HINT "100a"
STATUS current
DESCRIPTION
"Name of the task. Represents textual information taken from the
NVT ASCII character set. The character repertoire of the string is
restricted to printable, non-whitespace characters (codes 33 through
126)."
REFERENCE
"RFC 854: NVT ASCII character set."
SYNTAX OCTET STRING (SIZE(1..100))
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- MIB Structure
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemTrap OBJECT IDENTIFIER ::= { juniSystemMIB 0 }
juniSystemObjects OBJECT IDENTIFIER ::= { juniSystemMIB 1 }
juniSystemConformance OBJECT IDENTIFIER ::= { juniSystemMIB 2 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Managed objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemGeneral OBJECT IDENTIFIER ::= { juniSystemObjects 1 }
juniSystemSubsystem OBJECT IDENTIFIER ::= { juniSystemObjects 2 }
juniSystemModule OBJECT IDENTIFIER ::= { juniSystemObjects 3 }
juniSystemPort OBJECT IDENTIFIER ::= { juniSystemObjects 4 }
juniSystemTiming OBJECT IDENTIFIER ::= { juniSystemObjects 5 }
juniSystemFabric OBJECT IDENTIFIER ::= { juniSystemObjects 6 }
juniSystemNvs OBJECT IDENTIFIER ::= { juniSystemObjects 7 }
juniSystemPower OBJECT IDENTIFIER ::= { juniSystemObjects 8 }
juniSystemTemperature OBJECT IDENTIFIER ::= { juniSystemObjects 9 }
juniSystemUtilization OBJECT IDENTIFIER ::= { juniSystemObjects 10 }
juniSystemIssu OBJECT IDENTIFIER ::= { juniSystemObjects 11 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- General operational software system objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version identification of currently executing system-wide operational
software."
::= { juniSystemGeneral 1 }
juniSystemSwBuildDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Build date of currently executing system-wide operational software
version."
::= { juniSystemGeneral 2 }
juniSystemMemUtilPct OBJECT-TYPE
SYNTAX Integer32 (-1..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of memory utilization on the primary system processor. A
value of -1 indicates the utilization is unknown."
::= { juniSystemGeneral 3 }
juniSystemMemCapacity OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total memory capacity in bytes of the primary system processor. If
the memory capacity is greater than 2147483647, a -1 value is returned,
and the actual memory capacity (in number of bytes divided by 1024) is
returned in juniSystemMemKBytesCapacity."
::= { juniSystemGeneral 4 }
juniSystemMemKBytesCapacity OBJECT-TYPE
SYNTAX KBytes
UNITS "KBytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total memory capacity in kilo-bytes (1024 bytes) of the primary
system processor."
::= { juniSystemGeneral 23 }
juniSystemHighMemUtilThreshold OBJECT-TYPE
SYNTAX Integer32 (1..99)
UNITS "percent"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of memory utilization in the primary system processor, where,
if reached for the first time after a high memory threshold reset, a
high memory utilization event notification will be sent to the
management entity on this system. A high memory threshold reset occurs
when the system is initialized (booted) or the memory utilization falls
below the value in juniSystemAbatedMemUtilThreshold.
The value of this object must always be greater than the value of
juniSystemAbatedMemUtilThreshold."
DEFVAL { 85 }
::= { juniSystemGeneral 5 }
juniSystemAbatedMemUtilThreshold OBJECT-TYPE
SYNTAX Integer32 (0..98)
UNITS "percent"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of memory utilization in the primary system processor that is
used to determine when to send an abated memory utilization event
notification to the management entity on this system. The abated memory
utilization event occurs if a high memory threshold reset has not
occurred since the last high memory threshold event, and then the memory
utilization falls to or below the value of this object. The abated
memory utilization event then triggers a high memory threshold reset.
The value of this object must always be less than the value of
juniSystemHighMemUtilThreshold."
DEFVAL { 75 }
::= { juniSystemGeneral 6 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- General software system reload configuration objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemBootConfigControl OBJECT-TYPE
SYNTAX INTEGER {
file(0),
fileOnce(1),
factoryDefaults(2),
runningConfiguration(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System boot configuration control:
file - On a system reboot use the configuration
settings specified by the
juniSystemBootConfigFile. The
juniSystemBootConfigControl and
juniSystemBootConfigFile must be specified
together in the same set request PDU.
fileOnce - On the next system reboot use the
configuration settings specified by the
juniSystemBootConfigFile. Do not continue
to use this file after using it once; on
subsequent reboots use the running
configuration. The
juniSystemBootConfigControl and
juniSystemBootConfigFile must be specified
together in the same set request PDU.
factoryDefaults - On the next system reboot use the factory
default settings. On subsequent reboots use
the running configuration.
runningConfiguration - On a system reboot use the current
configuration settings."
::= { juniSystemGeneral 7 }
juniSystemBootBackupConfigControl OBJECT-TYPE
SYNTAX INTEGER {
file(0),
factoryDefaults(1),
none(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System boot backup configuration control is used to determine the
configuration to be used when the boot logic chooses backup mode:
file - On a system reboot in backup mode use the
configuration settings specified by the
juniSystemBootBackupConfigFile. If this option
is specified, juniSystemBootBackupConfigFile,
juniSystemBootBackupReleaseFile and this object
must be specified together in the same set
request PDU.
factoryDefaults - On a system reboot in backup mode use the
factory default configuration settings. If this
option is specified,
juniSystemBootBackupReleaseFile and this object
must be specified together in the same set
request PDU.
none - Disallow the boot logic from using the backup
release file and configuration (i.e., disable
backup mode)."
::= { juniSystemGeneral 8 }
juniSystemBootForceBackupControl OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System boot force backup control:
off - On the next system reboot do not force the boot logic to
choose backup mode.
on - On the next system reboot force the boot logic to choose
backup mode.
Attempting to set this object to on(1) while the
juniSystemBootBackupConfigControl is set to none(2) will result in an
error."
::= { juniSystemGeneral 9 }
juniSystemBootAutoRevertControl OBJECT-TYPE
SYNTAX INTEGER {
default(0),
never(1),
set(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system boot auto-revert control is used to determine when the boot
logic should choose backup mode based of the reboot history:
default - Use the default auto-revert tolerances: 3 reboots in 30
minutes.
never - Never auto-revert to backup mode.
set - Use the auto-revert tolerances specified by
juniSystemBootAutoRevertCountTolerance and
juniSystemBootAutoRevertTimeTolerance, which must be
specified in the same PDU as this object when this value
is specified."
::= { juniSystemGeneral 10 }
juniSystemBootAutoRevertCountTolerance OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967294)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The auto-revert reboot count tolerance, used in conjunction with the
value of juniSystemBootAutoRevertTimeTolerance when
juniSystemBootAutoRevertControl is set to set(2) in the same PDU. For
example, if this object is set to 4 and
juniSystemBootAutoRevertTimeTolerance is set to 1200, then the boot
logic will choose backup mode if 4 system reboots occur within 20
minutes. This object cannot be set to zero, but may contain a zero
value when juniSystemBootAutoRevertControl is set to never(1)."
::= { juniSystemGeneral 11 }
juniSystemBootAutoRevertTimeTolerance OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967294)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The auto-revert reboot time tolerance, used in conjunction with the
value of juniSystemBootAutoRevertCountTolerance when
juniSystemBootAutoRevertControl is set to set(2) in the same PDU. This
object cannot be set to zero, but will contain a zero value when
juniSystemBootAutoRevertControl is set to never(1)."
::= { juniSystemGeneral 12 }
juniSystemBootReleaseFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system-wide boot release file name, with extension '.rel'. On a
set operation, if there is no file found with the name specified, then
an error is returned."
::= { juniSystemGeneral 13 }
juniSystemBootConfigFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system-wide boot configuration file name. This object and the
juniSystemBootConfigControl object set to file(0) or fileOnce(1) must be
specified together in the same set request PDU. If
juniSystemBootConfigControl is file(0), only file names with extension
'.cnf' are allowed. If juniSystemBootConfigControl is fileOnce(1), only
file names with extensions '.cnf' or '.scr' are allowed. On a set
operation, if the extension is not appropriate or there is no file found
with the name specified, then an error is returned. If
juniSystemBootConfigControl is not set to file(0) or fileOnce(1) then a
get operation for this object will return a zero-length string."
DEFVAL { "" }
::= { juniSystemGeneral 14 }
juniSystemBootBackupReleaseFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system-wide backup boot release file name, with extension '.rel'.
A zero-length string indicates that there is no backup release file so
the primary release file (juniSystemBootReleaseFile) will be used. On a
set operation if there is no file found with the name specified, then an
error is returned. The juniSystemBootBackupConfigControl object with a
valid value other than none(2) must be specified together with this
object in the same set request PDU, and if the
juniSystemBootBackupConfigControl is set to file(0) then a valid
juniSystemBootBackupConfigFile must also be included in the set request
PDU."
DEFVAL { "" }
::= { juniSystemGeneral 15 }
juniSystemBootBackupConfigFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system-wide backup boot configuration file name, with extension
'.cnf'. The juniSystemBootBackupReleaseFile object, the
juniSystemBootBackupConfigControl object set to file(0), and this object
must be specified together in the same set request PDU. On a set
operation, if there is no file found with the name specified, then an
error is returned. If juniSystemBootBackupConfigControl is not set to
file(0) then a get operation for this object will return a zero-length
string."
DEFVAL { "" }
::= { juniSystemGeneral 16 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- System-wide module redundancy control objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemRedundancyRevertControl OBJECT-TYPE
SYNTAX INTEGER {
off(0),
immediate(1),
timeOfDay(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Global control for reverting primary modules back from their active
redundant spare modules:
off - Disable global reverts of redundant modules.
immediate - All redundant module pairs are to revert as soon as the
primary module is ready to enter the online state.
timeOfDay - All redundant module pairs are to revert at the time
specified by juniSystemRevertTimeOfDay, relative to
midnight based on the system clock time. This object
must be set concurrently with juniSystemRevertTimeOfDay
when this value is specified.
Note that this only applies to modules that have
juniSystemModuleRedundancySupport set to true(1)."
::= { juniSystemGeneral 17 }
juniSystemRedundancyRevertTimeOfDay OBJECT-TYPE
SYNTAX Integer32 (0..86399)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of seconds past midnight local time on any given day at
which time redundant slot reverts are allowed to occur. This object
must be set concurrently with juniSystemRevertControl { timeOfDay }."
::= { juniSystemGeneral 18 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Subsystem objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemSubsystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemSubsystemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of subsystems. A subsystem supports a 'family' of module types;
that is, each module type is supported by a particular software
subsystem. For example, the ERX channelized T1 line card (CT1-FULL) is
supported by the 'ct1' subsystem."
::= { juniSystemSubsystem 1 }
juniSystemSubsystemEntry OBJECT-TYPE
SYNTAX JuniSystemSubsystemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry containing information pertaining to a subsystem.
Subsystem information takes precedence over system-wide information, but
not over individual module information."
INDEX { juniSystemSubsystemIndex }
::= { juniSystemSubsystemTable 1 }
JuniSystemSubsystemEntry ::= SEQUENCE {
juniSystemSubsystemIndex Integer32,
juniSystemSubsystemName DisplayString,
juniSystemSubsystemBootReleaseFile DisplayString,
juniSystemSubsystemBootBackupReleaseFile DisplayString }
juniSystemSubsystemIndex OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Arbitrary subsystem identification number."
::= { juniSystemSubsystemEntry 1 }
juniSystemSubsystemName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the subsystem."
::= { juniSystemSubsystemEntry 2 }
juniSystemSubsystemBootReleaseFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The boot release file name for this subsystem, with extension '.rel'.
If a file name is specified (a non-zero-length string), then this
release file takes precedence over the system-wide boot release file
(juniSystemBootReleaseFile) just for modules of the type specified by
the subsystem name. On a set operation, if there is no file that
matches the name specified, then an inconsistentValue error will be
returned. Setting this object to a zero-length string deconfigures the
subsystem-specific backup release file."
DEFVAL { "" }
::= { juniSystemSubsystemEntry 3 }
juniSystemSubsystemBootBackupReleaseFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The backup boot release file name for this subsystem, with extension
'.rel'. If a file name is specified (a non-zero-length string), then
this release file takes precedence over the system-wide boot backup
release file (juniSystemBootBackupReleaseFile) just for modules of the
type specified by the subsystem name. This object cannot be set unless
the system has a backup file, which means that
juniSystemBootBackupReleaseFile must contain a file name (a
non-zero-length string). On a set operation, if there is no file that
matches the name specified, then an inconsistentValue error will be
returned. Setting this object to a zero-length string deconfigures the
subsystem-specific backup release file."
DEFVAL { "" }
::= { juniSystemSubsystemEntry 4 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Module Slot objects
-- A slot represents a position in a chassis that contains one or more phisical
-- modules (printed circuit boards) and/or sub-modules that operate together as
-- a functional unit.
-- A sub-module is a functionally independent portion of a physical module.
-- One physical module may contain more than one sub-module.
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemMaxSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest number assigned to a slot in the system. In a particular
hardware model, module slots have fixed numbers assigned to them, even
though in some instances there may be no actual slots associated with a
particular number. In all cases there is a maximum slot number that
will never be exceeded:
2 for ERX-3xx models
6 for ERX-7xx models
13 for ERX-14xx models
16 for E320 models
Note that slot numbers are zero-based."
::= { juniSystemModule 1 }
juniSystemMaxModulesPerSlot OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of modules and sub-modules (different levels) that
can be associated with a slot number in the system. This value is
constant for a particular hardware platform family. The number of
levels is 2 for a first generation E-series (ERX) platform and is 4 for
a second generation E-series platform.
For the first generation E-series (ERX) platform family:
level 1 - SRP or line card module
level 2 - I/O adapter module
For the second generation E-series platform family:
level 1 - Forwarding module or SRP sub-module
level 2 - Switch fabric slice (SFS) sub-module or module
level 3 - Bay 0 I/O adapter
level 4 - Bay 1 I/O adapter "
::= { juniSystemModule 2 }
juniSystemSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of system module slot physical container configuration
information."
::= { juniSystemModule 3 }
juniSystemSlotEntry OBJECT-TYPE
SYNTAX JuniSystemSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry describing the physical status of a system module slot
container, which is designated by its slot and level positions. There
is an entry in this table for all index pairs from { 0, 1 } to the
maximum for each index, { juniSystemMaxSlotNumber,
juniSystemMaxModulesPerSlot }, even if there is no corresponding module
slot container in the system. A request for an index value outside this
range will result in a 'no such' response."
INDEX { juniSystemSlotNumber,
juniSystemSlotLevel }
::= { juniSystemSlotTable 1 }
JuniSystemSlotEntry ::= SEQUENCE {
juniSystemSlotNumber Integer32,
juniSystemSlotLevel JuniSystemSlotLevel,
juniSystemSlotStatus INTEGER,
juniSystemSlotType JuniSystemSlotType }
juniSystemSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The slot number. The actual upper limit of valid values is
juniSystemMaxSlotNumber. Note that slot numbers are zero-based."
::= { juniSystemSlotEntry 1 }
juniSystemSlotLevel OBJECT-TYPE
SYNTAX JuniSystemSlotLevel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The relative position of a module or sub-module 'container' within a
slot."
::= { juniSystemSlotEntry 2 }
juniSystemSlotStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
noSlotContainer(1),
empty(2),
moduleNotPresent(3),
modulePresent(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the module slot container.
unknown - The existence of a container cannot be
determined
noSlotContainer - The physical container does not exist
empty - No module is present and no configuration
information is available for this container
moduleNotPresent - A module is configured but it is not currently
in its container
modulePresent - A module is inserted in the container "
::= { juniSystemSlotEntry 3 }
juniSystemSlotType OBJECT-TYPE
SYNTAX JuniSystemSlotType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The category of modules that can be configured for the container."
::= { juniSystemSlotEntry 4 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Module Status objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of system module and sub-module information. In this table, a
module refers to a physical module (board) or a sub-module.
A physical board may contain a single module or multiple sub-modules.
For example, an ERX line card is a single module and appears as single
entry in this table. An I/O adapter is a module that doesn't provide
any operaitonal state information and it also appears as a single entry
in this table. A second generation E-series SRP/SFS hardware module
contains two sub-modules, each with its own operational state
information: a System Resource Processor (SRP) sub-module and a Switch
Fabric Slice (SFS) sub-module, which appear as two separate entries in
this table, one for each sub-module."
::= { juniSystemModule 4 }
juniSystemModuleEntry OBJECT-TYPE
SYNTAX JuniSystemModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry that provides information about a specific system module
or sub-module in a particular module location. There are only entries
in this table for module locations that report a juniSystemSlotStatus of
moduleNotPresent(3) or modulePresent(4)."
INDEX { juniSystemSlotNumber,
juniSystemSlotLevel }
::= { juniSystemModuleTable 1 }
JuniSystemModuleEntry ::= SEQUENCE {
juniSystemModuleOperStatus INTEGER,
juniSystemModuleDisableReason INTEGER,
juniSystemModuleLastChange TimeTicks,
juniSystemModuleCurrentType JuniSystemModuleType,
juniSystemModuleExpectedType JuniSystemModuleType,
juniSystemModuleDescr DisplayString,
juniSystemModuleSlotSpan Integer32,
juniSystemModulePortCount Integer32,
juniSystemModuleSerialNumber DisplayString,
juniSystemModuleAssemblyPartNumber DisplayString,
juniSystemModuleAssemblyRev DisplayString,
juniSystemModulePhysicalIndex PhysicalIndex,
juniSystemModuleSoftwareSupport TruthValue,
juniSystemModuleRedundancySupport TruthValue,
juniSystemModuleLevelSpan Integer32 }
juniSystemModuleOperStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
notPresent(1),
disabled(2),
hardwareError(3),
booting(4),
initializing(5),
online(6),
standby(7),
inactive(8),
notResponding(9) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational status of the module (or sub-module):
unknown - The status of the module cannot be determined
notPresent - No hardware is currently present but there was a
module previously configured in this position (see
juniSystemModuleExpectedType);
juniSystemModuleCurrentType is unknown(0)
disabled - Disable for the reason specified in
juniSystemModuleDisableReason
hardwareError - Not operational due to a hardware failure
booting - In the process of booting
initializing - In the process of initialing
online - Fully operational
standby - In redundant standby mode
inactive - In redundant inactive mode
notResponding - Unable to communicate with the rest of the system "
::= { juniSystemModuleEntry 1 }
juniSystemModuleDisableReason OBJECT-TYPE
SYNTAX INTEGER {
none(0),
unknown(1),
assessing(2),
admin(3),
typeMismatch(4),
fabricLimit(5),
imageError(6) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the condition causing the module (or sub-module) to be
disabled:
none - Value when the module is not disabled
unknown - Unknown reason for disablement
assessing - The module content is being assessed (transient
initialization state)
admin - The module is administratively disabled
typeMismatch - The current module personality conflicts with
configuration associated with a different (expected)
module personality that previously occupied the slot
fabricLimit - Module resource requirements exceed available fabric
capacity
imageError - Software image for the module is missing or invalid"
::= { juniSystemModuleEntry 2 }
juniSystemModuleLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the value of juniSystemModuleOperStatus
last changed."
::= { juniSystemModuleEntry 3 }
juniSystemModuleCurrentType OBJECT-TYPE
SYNTAX JuniSystemModuleType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The personality of this module based on the combination of modules that
are currently inserted in the slot. This could be different from the
personality reported in juniSystemModuleExpectedType, in which case it
may be necessary to set juniSystemModuleControl for the module in the
primary level to 'flush' before the set of modules in this slot can be
made operational."
::= { juniSystemModuleEntry 4 }
juniSystemModuleExpectedType OBJECT-TYPE
SYNTAX JuniSystemModuleType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The personality for this module position based on the combination of
modules that were inserted in this slot when it was last configured.
The value of this object will be different than the value of
juniSystemModuleCurrentType when the value of juniSystemModuleOperStatus
is disabled(2) and the value of juniSystemModuleDisableReason is
typeMismatch(4). After one or more modules is removed from a slot,
configuration information associated with the slot (its 'personality')
may persist, inhibiting the operation of a different combination of
modules in the slot (when new modules are inserted) until
juniSystemModuleControl for the slot's primary module is set to
flush(1)."
::= { juniSystemModuleEntry 5 }
juniSystemModuleDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of the expected module in this slot."
::= { juniSystemModuleEntry 6 }
juniSystemModuleSlotSpan OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of slot positions that the expected module spans. Most
modules are only one slot wide, but some require extra space or
backplane resources. These modules are identified as being in the lower
numbered slot and spanning across the higher numbered slot(s)."
::= { juniSystemModuleEntry 7 }
juniSystemModulePortCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of physical ports supported by the expected module type in
this slot."
::= { juniSystemModuleEntry 8 }
juniSystemModuleSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of the expected module in this slot. The serial
number of the current module may be found in this module's
entPhysicalSerialNum. A serial number is for a hardware board, so if
there is more than one sub-module on a board, their serial numbers will
all be the same."
DEFVAL { "" }
::= { juniSystemModuleEntry 9 }
juniSystemModuleAssemblyPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part number of the expected module in this slot. The part number
of the current module may be found in this module's
entPhysicalModelName. A part number is for a hardware board, so if
there is more than one sub-module on a board, their part numbers will
all be the same."
DEFVAL { "" }
::= { juniSystemModuleEntry 10 }
juniSystemModuleAssemblyRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The revision level of the expected module in this slot. The revision
level of the current module may be found in this module's
entPhysicalHardwareRev. A revision level is for a hardware board, so if
there is more than one sub-module on a board, their revision levels will
all be the same."
DEFVAL { "" }
::= { juniSystemModuleEntry 11 }
juniSystemModulePhysicalIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entPhysicalIndex value assigned to the module. The
ENTITY-MIB.entPhysicalTable contains additional information about this
module that can be retrieved using this index. An entPhysicalIndex is
for a hardware board, so if there is more than one sub-module on a
board, their entPhysicalIndex values will all be the same."
::= { juniSystemModuleEntry 12 }
juniSystemModuleSoftwareSupport OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indicator as to whether this module or sub-module has operational
state information that can be managed. If the value of this object is
true(1), then there is an entry for this module or sub-module in the
juniSystemModuleSoftwareTable."
::= { juniSystemModuleEntry 13 }
juniSystemModuleRedundancySupport OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indicator as to whether this module or sub-module is part of a
redundancy group. If the value of this object is true(1), then there is
an entry for this module or sub-module in the
juniSystemModuleRedundancyTable."
::= { juniSystemModuleEntry 14 }
juniSystemModuleLevelSpan OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of level positions that the expected module spans. Most
modules are only one level 'high', but some require extra space or
backplane resources. These modules are identified as being in the lower
numbered level and spanning across the higher numbered level(s)."
::= { juniSystemModuleEntry 15 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Module Software objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemModuleSoftwareTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemModuleSoftwareEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of system module software information. This includes the
version of the software running on the particular module, the running
software's use of the modules resources and the modules operational
state.
Some module types don't contain loadable software (they execute
'firmware') but include support for some of the objects in this table.
For example, the E320 SFS (es2Sfs) modules only support
juniSystemModuleAdminStatus and juniSystemModuleControl. Appropriate
'default' values are returned for the other objects.
Some module types don't contain any software related information (e.g.,
ERX I/O adapters do not) in which case their value of
juniSystemModuleSoftwareSupport will be false and there will not be a
corresponding entry in this table."
::= { juniSystemModule 5 }
juniSystemModuleSoftwareEntry OBJECT-TYPE
SYNTAX JuniSystemModuleSoftwareEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry that provides software information about a specific
system module in a particular slot location."
INDEX { juniSystemSlotNumber,
juniSystemSlotLevel }
::= { juniSystemModuleSoftwareTable 1 }
JuniSystemModuleSoftwareEntry ::= SEQUENCE {
juniSystemModuleSoftwareVersion DisplayString,
juniSystemModuleCpuUtilPct Integer32,
juniSystemModuleMemUtilPct Integer32,
juniSystemModuleAdminStatus JuniEnable,
juniSystemModuleControl INTEGER,
juniSystemModuleBootReleaseFile DisplayString,
juniSystemModuleBootBackupReleaseFile DisplayString,
juniSystemModuleCpuFiveSecUtilPct Integer32,
juniSystemModuleCpuOneMinAvgPct Integer32,
juniSystemModuleCpuFiveMinAvgPct Integer32 }
juniSystemModuleSoftwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version identification of the currently executing operational software
on this module. If the module is in a state where the software version
is not known (e.g., module type mismatch), then the value of this object
will be a zero-length string."
::= { juniSystemModuleSoftwareEntry 2 }
juniSystemModuleCpuUtilPct OBJECT-TYPE
SYNTAX Integer32 (-1..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last available module CPU utilization percentage. A value of -1
indicates the utilization is unknown. This value is calculated over
a 5 second period."
::= { juniSystemModuleSoftwareEntry 3 }
juniSystemModuleMemUtilPct OBJECT-TYPE
SYNTAX Integer32 (-1..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of module memory utilization. A value of -1 indicates the
utilization is unknown."
::= { juniSystemModuleSoftwareEntry 4 }
juniSystemModuleAdminStatus OBJECT-TYPE
SYNTAX JuniEnable
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Provides administrative control to enable/disable the module. This
object is read-only for certain types of modules."
::= { juniSystemModuleSoftwareEntry 5 }
juniSystemModuleControl OBJECT-TYPE
SYNTAX INTEGER {
noOperation(0),
flush(1),
reset(2),
resetBackup(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Administrative control of this slot:
noOperation - Setting this value has no effect.
flush - Flushes the configuration associated with a module
type that previously occupied this slot. Used to
explicitly confirm that the slot is now empty, or
contains a different card type. The module must be
disabled when this value is asserted. See the
description for juniSystemModuleDisableReason.
reset - Resets the module.
resetBackup - Resets the module using the backup release file.
Get operations on this variable always return noOperation. Module types
that do not support these operations simply ignore them."
::= { juniSystemModuleSoftwareEntry 6 }
juniSystemModuleBootReleaseFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The boot release file name for this slot, with extension '.rel'. If a
file name is specified (not a zero-length string), then this release
file takes precedence over the subsystem boot release file
(juniSystemSubsystemBootReleaseFile) and the system-wide boot release
file (juniSystemBootReleaseFile) for just the module in this slot.
Some module types (e.g., ERX SRP modules) don't allow this object to be
set. On a set operation, if there is no file that matches the name
specified, then an inconsistentValue error will be returned. Setting
this object to a zero-length string deconfigures the slot-specific
primary release file."
DEFVAL { "" }
::= { juniSystemModuleSoftwareEntry 7 }
juniSystemModuleBootBackupReleaseFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The backup boot release file name for this slot, with extension '.rel'.
If a file name is specified (a non-zero-length string), then this
release file takes precedence over the subsystem boot backup release
file (juniSystemSubsystemBootBackupReleaseFile) and the system-wide boot
backup release file (juniSystemBootBackupReleaseFile) for just the
module in this slot.
This object cannot be set unless the system has a backup file, which
mean that juniSystemBootBackupReleaseFile must contain a file name (a
non-zero-length string). Some module types (e.g., ERX SRP modules)
don't allow this object to be set. On a set operation, if there is no
file that matches the name specified, then an inconsistentValue error
will be returned. Setting this object to a zero-length string
deconfigures the slot-specific backup release file."
DEFVAL { "" }
::= { juniSystemModuleSoftwareEntry 8 }
juniSystemModuleCpuFiveSecUtilPct OBJECT-TYPE
SYNTAX Integer32 (-1..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of average CPU utilization for the last five sec for this
module. A value of -1 indicates the utilization is unknown."
::= { juniSystemModuleSoftwareEntry 9 }
juniSystemModuleCpuOneMinAvgPct OBJECT-TYPE
SYNTAX Integer32 (-1..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of average CPU utilization for the last one minute for this
module. A value of -1 indicates the utilization is unknown."
::= { juniSystemModuleSoftwareEntry 10 }
juniSystemModuleCpuFiveMinAvgPct OBJECT-TYPE
SYNTAX Integer32 (-1..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage of average CPU utilization for the last five minutes for
this module. A value of -1 indicates the utilization is unknown."
::= { juniSystemModuleSoftwareEntry 11 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Module Redundancy objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemModuleRedundancyTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemModuleRedundancyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of system module redundancy information. Note that modules
that do not support redundancy information will not appear in this
table."
::= { juniSystemModule 6 }
juniSystemModuleRedundancyEntry OBJECT-TYPE
SYNTAX JuniSystemModuleRedundancyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry that provides information about a specific system module
in a particular slot location."
INDEX { juniSystemSlotNumber,
juniSystemSlotLevel }
::= { juniSystemModuleRedundancyTable 1 }
JuniSystemModuleRedundancyEntry ::= SEQUENCE {
juniSystemModuleRedundancyGroupId Unsigned32,
juniSystemModuleRedundancySpare TruthValue,
juniSystemModuleRedundancyAssociatedSlot Integer32,
juniSystemModuleRedundancyLockout JuniEnable,
juniSystemModuleRedundancyRevertControl INTEGER,
juniSystemModuleRedundancyRevertTime DateAndTime }
juniSystemModuleRedundancyGroupId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the redundancy group as derived from hardware settings."
::= { juniSystemModuleRedundancyEntry 1 }
juniSystemModuleRedundancySpare OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True only if this module is a spare redundant module."
::= { juniSystemModuleRedundancyEntry 2 }
juniSystemModuleRedundancyAssociatedSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If this module is a primary redundant module, then the module at the
same slot level with the slot number identified by this variable is the
spare module that serves as this module's backup.
If this module is an active spare redundant module, then the module in
the slot identified by this variable is the primary module for which
this module is the spare.
If this module is an inactive spare redundant module, then the value of
this object is the slot number of the spare itself (the same value as
the first index)."
::= { juniSystemModuleRedundancyEntry 3 }
juniSystemModuleRedundancyLockout OBJECT-TYPE
SYNTAX JuniEnable
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Provides administrative control to enable/disable redundancy protection
for the module in this slot."
::= { juniSystemModuleRedundancyEntry 4 }
juniSystemModuleRedundancyRevertControl OBJECT-TYPE
SYNTAX INTEGER {
off(0),
immediate(1),
timeAndDate(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Per-module control for reverting a primary module back from its active
redundant spare module:
off - Disable reverting to the primary module.
immediate - Revert as soon as this primary module is ready to
enter the online state.
timeAndDate - Revert to this primary module at time specified by
juniSystemModuleRedundancyRevertTime, provided it is
in the inactive state.
This control only applies to primary modules; spare modules can only be
set to off(0)."
::= { juniSystemModuleRedundancyEntry 5 }
juniSystemModuleRedundancyRevertTime OBJECT-TYPE
SYNTAX DateAndTime (SIZE(8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The date and time associated with the timeAndDate (delayed) revert
operation. Only the local format for DateAndTime is supported. On a
set operation, if the time specified is prior to the current time, then
an inconsistent value error is returned.This object must be set concurrently
with juniSystemModuleRedundancyRevertControl { timeAndDate(2) }."
::= { juniSystemModuleRedundancyEntry 6 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- I/O Port objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of system physical I/O ports. The information in this table
reflects the ports for the expected module type in each slot; in event
of a module mismatch, this table permits navigation of the existing
configuration of the expected module type."
::= { juniSystemPort 1 }
juniSystemPortEntry OBJECT-TYPE
SYNTAX JuniSystemPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry describing a physical port of the system."
INDEX { juniSystemSlotNumber,
juniSystemSlotLevel,
juniSystemPortNumber }
::= { juniSystemPortTable 1 }
JuniSystemPortEntry ::= SEQUENCE {
juniSystemPortNumber Integer32,
juniSystemPortIfIndex InterfaceIndexOrZero,
juniSystemPortPhysicalIndex PhysicalIndex }
juniSystemPortNumber OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port number of this physical port, relative to the slot in which it
resides. Each physical port is uniquely distinguished by its slot
number, slot level and port number. Port numbers are zero-based."
::= { juniSystemPortEntry 1 }
juniSystemPortIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex of the Interfaces MIB ifTable entry corresponding to this
physical port; if zero, the ifIndex is unknown or does not exist."
::= { juniSystemPortEntry 2 }
juniSystemPortPhysicalIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entPhysicalIndex value assigned to this port. This index may be
use to retrieve other information about the port, such as description
and type, from the ENTITY-MIB.entPhysicalTable."
::= { juniSystemPortEntry 3 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Timing objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemAdminTimingSource OBJECT-TYPE
SYNTAX JuniSystemTimingSelector
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative timing source for the system. This variable is used
to select the desired timing source to be either primary, secondary or
tertiary. Setting this variable will cause the system to change to the
specified timing source, provided it is currently available. Setting
this value to error(4) is not allowed.
The system periodically monitors the status of the three timing sources.
If the systems current timing source fails, the system will
automatically downgrade to the next timing source. If the system is
configured to automatically upgrade (juniSystemTimingAutoUpgrade is set
to enable(1)) the system will switch back to the timing source indicated
by this variable when it becomes available.
A timing source failure can be detected by comparing the operational and
administrative timing sources. If they are not equal, the system has
swapped timing sources because the administratively set timing source is
in the error state."
::= { juniSystemTiming 1 }
juniSystemOperTimingSource OBJECT-TYPE
SYNTAX JuniSystemTimingSelector
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational timing source for the system. The system periodically
monitors the status of three timing sources, primary, secondary and
tertiary. If the systems current timing source fails, the system will
automatically downgrade to the next timing source. If the system is
configured to automatically upgrade (juniSystemTimingAutoUpgrade is set
to enable(1)) the system will switch back to the higher timing source
when it becomes available."
::= { juniSystemTiming 2 }
juniSystemTimingAutoUpgrade OBJECT-TYPE
SYNTAX JuniEnable
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the automatic timing selector upgrade. Setting
this object to disable(0) will prevent automatic upgrade to the next
highest timing selector. Setting this object to enable(1) will enable
the automatic upgrade of timing selectors."
DEFVAL { enable }
::= { juniSystemTiming 3 }
juniSystemTimingSelectorTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemTimingSelectorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of system timing selectors. This table only contains entries for
the primary, secondary and tertiary selecors."
::= { juniSystemTiming 4 }
juniSystemTimingSelectorEntry OBJECT-TYPE
SYNTAX JuniSystemTimingSelectorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry describing a system timing selector."
INDEX { juniSystemTimingSelectorIndex }
::= { juniSystemTimingSelectorTable 1 }
JuniSystemTimingSelectorEntry ::= SEQUENCE {
juniSystemTimingSelectorIndex JuniSystemTimingSelector,
juniSystemTimingSourceType INTEGER,
juniSystemTimingSourceIfIndex InterfaceIndexOrZero,
juniSystemTimingSourceLine INTEGER,
juniSystemTimingWorkingStatus INTEGER,
juniSystemTimingProtectedStatus INTEGER }
juniSystemTimingSelectorIndex OBJECT-TYPE
SYNTAX JuniSystemTimingSelector
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The system timing selector index associated with this entry. There are
valid indexes for selector types primary(1), secondary(2), tertiary(3)."
::= { juniSystemTimingSelectorEntry 1 }
juniSystemTimingSourceType OBJECT-TYPE
SYNTAX INTEGER {
timingInterfaceIfIndex(1),
timingInternal(2),
timingLine(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system timing source type for this entry. This object must be set
to timingInterfaceIfIndex(1) when setting the
juniSystemTimingSourceIfIndex object or timingLine(3) when setting the
juniSystemTimingSourceLine object. Also, if the value of this object is
set to timingInternal(2), no other objects should be set, otherwise the
agent will return an error."
::= { juniSystemTimingSelectorEntry 2 }
juniSystemTimingSourceIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ifIndex of the interface selected as the system timing source. If
the juniSystemTimingSourceType object is not timingInterfaceIfIndex(1),
then reading this object will return a zero value. The agent will not
accept a set to this object unless the juniSystemTimingSourceType object
is set to timingInterfaceIfIndex(1)."
DEFVAL { 0 }
::= { juniSystemTimingSelectorEntry 3 }
juniSystemTimingSourceLine OBJECT-TYPE
SYNTAX INTEGER {
timingSourceLineUndefined(0),
timingSourceLineE1PortA(1),
timingSourceLineE1PortB(2),
timingSourceLineT1PortA(3),
timingSourceLineT1PortB(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The line type timing source for this entry. If the
juniSystemTimingSourceType object is not timingLine(3), then reading
this object will return timingSourceLineUndefined(0). The agent will
not accept a set to this object unless the juniSystemTimingSourceType
object is set to timingLine(3). Attempting to set this object to
timingSourceLineUndefined(0) will always return an inconsistantValue
error. Attempting to set this object to a value that is not supported
on the type of system running the agent will result in an
inconsistantValue error."
DEFVAL { timingSourceLineUndefined }
::= { juniSystemTimingSelectorEntry 4 }
juniSystemTimingWorkingStatus OBJECT-TYPE
SYNTAX INTEGER {
timingStatusOk(1),
timingStatusError(2),
timingStatusUnknown(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status associated with the working (normal) source of this system
timing working selector."
::= { juniSystemTimingSelectorEntry 5 }
juniSystemTimingProtectedStatus OBJECT-TYPE
SYNTAX INTEGER {
timingStatusOk(1),
timingStatusError(2),
timingStatusUnknown(3),
sourceNotProtected(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status associated with the protected (backup) source of this system
timing selector. If the system doesn't support protected timing
sources, then sourceNotProtected(4) will be returned."
::= { juniSystemTimingSelectorEntry 6 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Fabric objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemFabricSpeed OBJECT-TYPE
SYNTAX Unsigned32
UNITS "gigabits per second"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The speed of switching fabric, in gigabits per second."
::= { juniSystemFabric 1 }
juniSystemFabricRev OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fabric revision number. If unknown, a zero-length string is
reported."
::= { juniSystemFabric 2 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Non-Volatile Storage status objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemNvsCount OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of non-volatile storage (NVS) 'flash' cards in the system."
::= { juniSystemNvs 1 }
juniSystemNvsTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemNvsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of NVS status information."
::= { juniSystemNvs 2 }
juniSystemNvsEntry OBJECT-TYPE
SYNTAX JuniSystemNvsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry that provides the status information for a NVS flash
card."
INDEX { juniSystemNvsIndex }
::= { juniSystemNvsTable 1 }
JuniSystemNvsEntry ::= SEQUENCE {
juniSystemNvsIndex Integer32,
juniSystemNvsStatus INTEGER,
juniSystemNvsCapacity Unsigned32,
juniSystemNvsUtilPct Integer32,
juniSystemNvsPhysicalIndex PhysicalIndex }
juniSystemNvsIndex OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index number of the NVS flash card. There is an entry in this
table for all values of this index in the range of 1 to the value of
juniSystemNvsCount."
::= { juniSystemNvsEntry 1 }
juniSystemNvsStatus OBJECT-TYPE
SYNTAX INTEGER {
notPresent(0),
writeProtected(1),
volumeError(2),
nearCapacity(3),
ok(4),
noConfigSpace(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of non-volatile storage (NVS):
notPresent - The SRP or the flash card is not accessible.
writeProtected - NVS is write-protected.
volumeError - Status poll of NVS failed.
nearCapacity - Utilization exceeds 85% of NVS capacity.
ok - NVS is fully operational with ample capacity.
noConfigSpace - Utilization exceeds the ability to save the
running configuration."
::= { juniSystemNvsEntry 2 }
juniSystemNvsCapacity OBJECT-TYPE
SYNTAX Unsigned32
UNITS "megabytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The capacity of NVS storage in megabytes."
::= { juniSystemNvsEntry 3 }
juniSystemNvsUtilPct OBJECT-TYPE
SYNTAX Integer32 (-1..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of NVS storage used. A value of -1 indicates NVS
utilization is unknown."
::= { juniSystemNvsEntry 4 }
juniSystemNvsPhysicalIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entPhysicalIndex value assigned to this NVS flash card. This index
may be use to retrieve other information about the NVS flash card, such
as description and type, from the ENTITY-MIB.entPhysicalTable."
::= { juniSystemNvsEntry 5 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Power element objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemPowerCount OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of power elements in the system."
::= { juniSystemPower 1 }
juniSystemPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of status variables for the system power elements."
::= { juniSystemPower 2 }
juniSystemPowerEntry OBJECT-TYPE
SYNTAX JuniSystemPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry describing status of a system power element."
INDEX { juniSystemPowerIndex }
::= { juniSystemPowerTable 1 }
JuniSystemPowerEntry ::= SEQUENCE {
juniSystemPowerIndex Integer32,
juniSystemPowerStatus INTEGER,
juniSystemPowerPhysicalIndex PhysicalIndex }
juniSystemPowerIndex OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index number of the power element. There is an entry in this table
for all values of this index in the range of 1 to the value of
juniSystemPowerCount."
::= { juniSystemPowerEntry 1 }
juniSystemPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
notPresent(0),
inactive(1),
good(2),
failed(3),
sensorFailed(4),
unknown(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the power element:
notPresent - The power element is removed from the chassis.
inactive - No power is available from this element.
good - Power is available from this element.
failed - The power element is not working.
sensorFailed - The power element sensor has failed.
unknown - The status of the power element is not availiable."
::= { juniSystemPowerEntry 2 }
juniSystemPowerPhysicalIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entPhysicalIndex value assigned to this power element. This index
may be use to retrieve other information about the power element, such
as description and type, from the ENTITY-MIB.entPhysicalTable."
::= { juniSystemPowerEntry 3 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Temperature control (fan subsystem) objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemFanCount OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of fan subsystems that may be present in the system.
This is a fixed number for each product type."
::= { juniSystemTemperature 1 }
juniSystemFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of status of the system's fan subsystems."
::= { juniSystemTemperature 2 }
juniSystemFanEntry OBJECT-TYPE
SYNTAX JuniSystemFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry describing status of a fan subsystem."
INDEX { juniSystemFanIndex }
::= { juniSystemFanTable 1 }
JuniSystemFanEntry ::= SEQUENCE {
juniSystemFanIndex Integer32,
juniSystemFanStatus INTEGER,
juniSystemFanPhysicalIndex PhysicalIndex }
juniSystemFanIndex OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index number of the fan subsystem. This is a number in the range
of 1 to the value of juniSystemFanCount."
::= { juniSystemFanEntry 1 }
juniSystemFanStatus OBJECT-TYPE
SYNTAX INTEGER {
failed(0),
ok(1),
warning(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of fan subsystem.
failed - The fan subsystem has a critical failure, or has been
removed, and is now non-operational.
ok - All components are operational.
warning - The fan subsystem has a non-critical failure."
::= { juniSystemFanEntry 2 }
juniSystemFanPhysicalIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entPhysicalIndex value assigned to this fan subsystem. This index
may be use to retrieve other information about the fan subsystem, such
as description and type, from the ENTITY-MIB.entPhysicalTable."
::= { juniSystemFanEntry 3 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Temperature sensor objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemTempCount OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of possible temperature sensors in the system."
::= { juniSystemTemperature 3 }
juniSystemTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of status of the system's temperature sensors."
::= { juniSystemTemperature 4 }
juniSystemTempEntry OBJECT-TYPE
SYNTAX JuniSystemTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry describing status of a temperature sensor. Sensors are
located throughout the system. The ENTITY_MIB.entPhysicalTable provides
detailed information about the location of each sensor. The index for a
table entry is fixed based on a product-specific algorithm that uses the
maximum number of sensors that may be on any module type associated with
each of the available slots. This means that entries for sensors
associated with empty slots and the 'extra' sensors on modules that have
less than the maximum number of sensors for the slot type will have a
notPresent status."
INDEX { juniSystemTempIndex }
::= { juniSystemTempTable 1 }
JuniSystemTempEntry ::= SEQUENCE {
juniSystemTempIndex Integer32,
juniSystemTempStatus INTEGER,
juniSystemTempValue Integer32,
juniSystemTempPhysicalIndex Integer32 }
juniSystemTempIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary number to uniquely identify the temperature sensor."
::= { juniSystemTempEntry 1 }
juniSystemTempStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
failed(1),
tooLow(2),
nominal(3),
tooHigh(4),
tooLowWarning(5),
tooHighWarning(6) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a temperature sensor:
unknown - sensor is not present or is not accessible
failed - sensor is broken
tooLow - temperature is below nominal range
nominal - temperature is within nominal range
tooHigh - temperature is above nominal range
tooLowWarning - temperature is near the nominal lower limit
tooHighWarning - temperature is near the nominal upper limit "
::= { juniSystemTempEntry 2 }
juniSystemTempValue OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature measured by this sensor in degrees Celsius. This
measurement is valid only if the value of the corresponding
juniSystemTempStatus is tooLow, nominal or tooHigh."
::= { juniSystemTempEntry 3 }
juniSystemTempPhysicalIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The entPhysicalIndex value assigned to this temperature sensor. If the
temperature sensor is not present this object will return a value of 0.
For non-zero values this index may be used to retrieve other information
about the temperature sensor from the ENTITY-MIB.entPhysicalTable, such
as description and location."
::= { juniSystemTempEntry 4 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Thermal protection objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemTempProtectionStatus OBJECT-TYPE
SYNTAX INTEGER {
off(0),
monitoring(1),
inHoldOff(2),
activatedHoldOffExpired(3),
activatedTempTooHigh(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Thermal Protection status:
off - No thermal protection.
monitoring - Monitoring.
inHoldOff - Hold off time has begun.
activatedHoldOffExpired - Hold off time has expired; the system
is in thermal protection mode.
activatedTempTooHigh - The temperature is too high, the system
is in thermal protection mode."
::= { juniSystemTemperature 5 }
juniSystemTempProtectionHoldOffTime OBJECT-TYPE
SYNTAX Integer32 (0..1200)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time, in seconds, before the system enters Thermal Protection mode
after a critical thermal failure is detected."
DEFVAL { 150 }
::= { juniSystemTemperature 6 }
juniSystemTempProtectionHoldOffTimeRemaining OBJECT-TYPE
SYNTAX Integer32 (0..1200)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time remaining, in seconds, before the system enters Thermal
Protection mode while the ThermalProtectionStatus is set to inHoldOff.
The value decrements every second until it reaches zero, and the status
changes to activatedHoldOffExpired. When ThermalProtectionStatus is not
inHoldOff or activatedHoldOffExpired, the value is set to the hold off
time."
DEFVAL { 150 }
::= { juniSystemTemperature 7 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Resource utilization objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
--
-- Resource utilization status table
--
juniSystemUtilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of status of the utilization of system resources. It is an
implementation option as to which resources (if any) are supported in
this table. It is also an implementation option as to whether the
threshold objects are supported for a particular instance."
::= { juniSystemUtilization 1 }
juniSystemUtilizationEntry OBJECT-TYPE
SYNTAX JuniSystemUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry describing the status of the utilization of a system
resource."
INDEX { juniSystemUtilizationResourceType,
juniSystemUtilizationResourceSubType,
juniSystemUtilizationLocationType,
juniSystemUtilizationLocation }
::= { juniSystemUtilizationTable 1 }
JuniSystemUtilizationEntry ::= SEQUENCE {
juniSystemUtilizationResourceType INTEGER,
juniSystemUtilizationResourceSubType Integer32,
juniSystemUtilizationLocationType JuniSystemLocationType,
juniSystemUtilizationLocation JuniSystemLocation,
juniSystemUtilizationMaxCapacity Gauge32,
juniSystemUtilizationCurrentValue Gauge32,
juniSystemUtilizationThresholdRising Gauge32,
juniSystemUtilizationThresholdFalling Gauge32,
juniSystemUtilizationHoldDownTime Gauge32 }
juniSystemUtilizationResourceType OBJECT-TYPE
SYNTAX INTEGER {
interface(1),
memory(2) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This index identifies a type of enumerated value that is used for the
juniSystemUtilizationResourceSubType. See the DESCRIPTION for
juniSystemUtilizationResourceSubType for the mapping of Type to SubType
enumeration and the corresponding units of measure used for each type of
resource."
::= { juniSystemUtilizationEntry 1 }
juniSystemUtilizationResourceSubType OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This index uses an enumerated value that is different for each value of
juniSystemUtilizationResourceType. The following table shows the
mapping of Type to SubType enumeration and the corresponding units of
measure used for each type of resource.
Type SubType Units
-----------+-------------------------------+----------------------------
interface Juniper-UNI-IF-MIB.juniIfType number of interfaces
memory SNMPv2-TC.StorageType HOST-RESOURCES-MIB.KBytes "
::= { juniSystemUtilizationEntry 2 }
juniSystemUtilizationLocationType OBJECT-TYPE
SYNTAX JuniSystemLocationType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This index element identifies the format of the location information so
that the juniSystemUtilizationLocation index element can be properly
interpreted."
::= { juniSystemUtilizationEntry 3 }
juniSystemUtilizationLocation OBJECT-TYPE
SYNTAX JuniSystemLocation
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This index is used to specify the resource instance based on its
location. Its value is interpreted based on the location type
identified by the juniSystemUtilizationLocationType index element."
::= { juniSystemUtilizationEntry 4 }
juniSystemUtilizationMaxCapacity OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of units of the resource the system can support.
See the DESCRIPTION of juniSystemUtilizationResourceSubType for what
constitutes a unit of value for this object.
Note that for some resources this value may not always be achievable due
to other resource constraints."
::= { juniSystemUtilizationEntry 5 }
juniSystemUtilizationCurrentValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current number of units of the resource in the system.
See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
constitutes a unit of value for this object.
Note that some resource types may have instances that do not consume any
limited resources and therefore are not included in this count (e.g. IP
loopback interfaces do not consume routing resources and therefore don't
have a capacity limit, whereas 'external' IP interfaces do)."
::= { juniSystemUtilizationEntry 6 }
juniSystemUtilizationThresholdRising OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value (risingVal), which, in conjunction with
juniSystemUtilizationHoldDownTime (holdTime) and
juniSystemUtilizationThresholdFalling (fallingVal), is used to decide
when to trigger an event indicating that the resource utilization,
juniSystemUtilizationCurrentValue (currentVal), is approaching or has
reached its maximum capacity, juniSystemUtilizationMaxCapacity (maxVal).
See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
constitutes a unit of value for this object.
The value of fallingVal must be less than the value of this object.
This object provides one element in the formula used to determine when
to send a utilization notification. If the currentVal rises to equal
the risingVal and no other utilization event (either rising or falling)
has been triggered within the holdTime, or if the holdTime for a falling
threshold notification expires and the currentVal is at or above the
risingVal, then and only then is a rising threshold utilization
notification sent.
The following pseudo-code states the algorithm more precisely.
When the resource is created or initialized ( currentVal == 0 ):
lastTrapType = none;
lastTrapTime = 0;
When currentVal increments (increases):
if ( currentVal == risingVal &&
lastTrapTime + holdTime <= currentTime ) {
triggerUtilizationTrapRising();
lastTrapType = rising;
lastTrapTime = currentTime; }
When currentVal decrements (decreases):
if ( currentVal == fallingVal &&
lastTrapTime + holdTime <= currentTime ) {
triggerUtilizationTrapFalling();
lastTrapType = falling;
lastTrapTime = currentTime; }
When the rising threshold value is modified:
if ( currentVal < oldRisingVal &&
currentVal >= newRisingVal &&
lastTrapTime + holdTime <= currentTime )
triggerUtilizationTrapRising();
lastTrapType = rising;
lastTrapTime = currentTime; }
When the falling threshold value is modified:
if ( currentVal > oldFallingVal &&
currentVal <= newFallingVal &&
lastTrapTime + holdTime <= currentTime )
triggerUtilizationTrapFalling();
lastTrapType = falling;
lastTrapTime = currentTime; }
When a hold-down time expires (lastTrapTime + holdTime == currentTime):
switch ( lastTrapType ) {
case rising:
if ( currentVal <= fallingVal ) {
triggerUtilizationTrapFalling();
lastTrapType = falling;
lastTrapTime = currentTime; }
else {
lastTrapType = none; }
break;
case falling:
if ( currentVal >= risingVal ) {
triggerUtilizationTrapRising();
lastTrapType = rising;
lastTrapTime = currentTime; }
else {
lastTrapType = none; }
break; } "
::= { juniSystemUtilizationEntry 7 }
juniSystemUtilizationThresholdFalling OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value (fallingVal), which, in conjunction with
juniSystemUtilizationHoldDownTime (holdTime) and
juniSystemUtilizationThresholdRising (risingVal), is used to decide when
to trigger an event indicating that the resource utilization,
juniSystemUtilizationCurrentValue (currentVal), has fallen to or below
this level after having exceeded this value.
See the DESCRIPTION for juniSystemUtilizationResourceSubType for what
constitutes a unit of value for this object.
The value of this object must be less than the value of risingVal.
This object provides one element in the formula used to determine when
to send a utilization notification. If the currentVal falls to equal
the fallingVal and no other utilization event (either rising or falling)
has been triggered within the holdTime, or if the holdTime for a rising
threshold notification expires and the currentVal is at or below the
fallingVal, then and only then is a falling threshold utilization
notification sent.
The pseudo-code in the juniSystemUtilizationThresholdRising DESCRIPTION
states the algorithm more precisely."
::= { juniSystemUtilizationEntry 8 }
juniSystemUtilizationHoldDownTime OBJECT-TYPE
SYNTAX Gauge32
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The hold-down time (holdTime) used in conjunction with
juniSystemUtilizationThresholdRising (risingVal) and
juniSystemUtilizationThresholdFalling (fallingVal) to decide when to
trigger an event indicating that the resource utilization,
juniSystemUtilizationCurrentValue (currentVal), has reached or surpassed
one of the thresholds.
This object provides one element in the formula used to determine when
to send a utilization notification. If the resource utilization
increases to the rising threshold value but a prior rising or falling
utilization event has been triggered within this hold-down time then no
rising threshold utilization notification may be sent at that time. If
the resource utilization decreases to the falling threshold value but a
prior rising or falling utilization event has been triggered within this
hold-down time then no falling threshold utilization notification may be
sent at that time. However, if the end of a hold-down period for a
rising threshold utilization notification is reached and the current
value is at or below the falling threshold value, then a falling
threshold notification is sent and the hold-down timer is restarted.
Likewise, if the end of a hold-down period for a falling threshold
utilization notification is reached and the current value is at or above
the rising threshold value, then a rising threshold notification is sent
and the hold-down timer is restarted.
The pseudo-code in the juniSystemUtilizationThresholdRising DESCRIPTION
states the algorithm more precisely."
::= { juniSystemUtilizationEntry 9 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Task profiling (process cpu utilization) objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemCpuUtilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemCpuUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of status of the cpu utilization by various tasks."
::= { juniSystemUtilization 2 }
juniSystemCpuUtilizationEntry OBJECT-TYPE
SYNTAX JuniSystemCpuUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry describing cpu utilization of a particular task."
INDEX { juniSystemCpuUtilizationTimeMark,
juniSystemCpuUtilizationTaskName }
::= { juniSystemCpuUtilizationTable 1 }
JuniSystemCpuUtilizationEntry ::= SEQUENCE {
juniSystemCpuUtilizationTimeMark JuniTimeFilter,
juniSystemCpuUtilizationTaskName JuniSystemTaskName,
juniSystemCpuUtilizationInvoked Integer32,
juniSystemCpuUtilizationInvokationPerSec Integer32,
juniSystemCpuUtilizationTotalRunningTime Integer32,
juniSystemCpuUtilizationPercentageRunningTime Integer32,
juniSystemCpuUtilizationAverageTimePerInvokation Integer32,
juniSystemCpuUtilizationFiveSecondUtilization Integer32,
juniSystemCpuUtilizationOneMinuteUtilization Integer32,
juniSystemCpuUtilizationFiveMinuteUtilization Integer32,
juniSystemCpuUtilizationNumberOfInstances Integer32 }
juniSystemCpuUtilizationTimeMark OBJECT-TYPE
SYNTAX JuniTimeFilter
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A TimeFilter for this task profile entry. Allows GetNext and GetBulk
to find task profile rows which have changed since a specified
value of sysUptime."
REFERENCE
"Refer to RFC 2021 for the definition of the TimeFilter, its usage and
implementation notes."
::= { juniSystemCpuUtilizationEntry 1 }
juniSystemCpuUtilizationTaskName OBJECT-TYPE
SYNTAX JuniSystemTaskName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Task name associated with this task profile entry."
::= { juniSystemCpuUtilizationEntry 2 }
juniSystemCpuUtilizationInvoked OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times task associated with this task profile
entry being invoked."
::= { juniSystemCpuUtilizationEntry 3 }
juniSystemCpuUtilizationInvokationPerSec OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rate of invokation for the task associated with this task
profile entry."
::= { juniSystemCpuUtilizationEntry 4 }
juniSystemCpuUtilizationTotalRunningTime OBJECT-TYPE
SYNTAX Integer32
UNITS "milli Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total running time for the task associated with this task
profile entry."
::= { juniSystemCpuUtilizationEntry 5 }
juniSystemCpuUtilizationPercentageRunningTime OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Percentage running time for the task associated with this task
profile entry."
::= { juniSystemCpuUtilizationEntry 6 }
juniSystemCpuUtilizationAverageTimePerInvokation OBJECT-TYPE
SYNTAX Integer32
UNITS "micro Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average running time per invokation for the task associated
with this task profile entry."
::= { juniSystemCpuUtilizationEntry 7 }
juniSystemCpuUtilizationFiveSecondUtilization OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Utilization in terms of percentage during the five seconds measurement
interval for the task associated with this task profile entry."
::= { juniSystemCpuUtilizationEntry 8 }
juniSystemCpuUtilizationOneMinuteUtilization OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Utilization in terms of percentage during the one minute measurement
interval for the task associated with this task profile entry."
::= { juniSystemCpuUtilizationEntry 9 }
juniSystemCpuUtilizationFiveMinuteUtilization OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Utilization in terms of percentage during the five minutes measurement
interval for the task associated with this task profile entry."
::= { juniSystemCpuUtilizationEntry 10 }
juniSystemCpuUtilizationNumberOfInstances OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of instances consolidated for CPU utilization calculation in this
task profile entry."
::= { juniSystemCpuUtilizationEntry 11 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- ISSU objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemIssuState OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
initializing(2),
initialized(3),
upgrading(4),
stopping(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the system with respect to ISSU upgrade:
idle - ISSU is currently idle
initializing - ISSU initialization is in-progress
initialized - ISSU has successfully initialized
upgrading - ISSU is currently upgrading to the new armed release
stopping - ISSU is currently in the process of stopping
This object is supported on the second generation E-series
platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
releases. This object is also supported on ERX-1440 in JUNOSe 9.2
and subsequent system releases."
::= { juniSystemIssu 1 }
juniSystemIssuRunningReleaseFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The currently running release file name, with extension '.rel'.
The system was booted last time with this release file.
This object is supported on the second generation E-series
platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
releases. This object is also supported on ERX-1440 in JUNOSe 9.2
and subsequent system releases."
::= { juniSystemIssu 2 }
juniSystemIssuArmedReleaseFile OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The currently armed release file name, with extension '.rel'.
The system will be booted with this release file, after ISSU (if
it is not aborted).
This object is supported on the second generation E-series
platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
releases. This object is also supported on ERX-1440 in JUNOSe 9.2
and subsequent system releases."
::= { juniSystemIssu 3 }
juniSystemIssuStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
warning(2),
error(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the system with respect to ISSU upgrade.
ok - no error or warning found
warning - at least one upgrade warning found, upgrade is possible
error - at least one upgrade error found, upgrade is not possible
This object is supported on the second generation E-series
platform family (E320 & E120) in JUNOSe 9.0 and subsequent system
releases. This object is also supported on ERX-1440 in JUNOSe 9.2
and subsequent system releases."
::= { juniSystemIssu 4 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- ISSU upgrade Criteria
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemIssuCriteriaTable OBJECT-TYPE
SYNTAX SEQUENCE OF JuniSystemIssuCriteriaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Table of criteria for an ISSU initialization.
This table will be empty for unsupported platforms. These objects
are supported on the second generation E-series platform
family (E320 & E120) in JUNOSe 9.0 and subsequent system releases.
This object is also supported on ERX-1440 in JUNOSe 9.2 and
subsequent system releases."
::= { juniSystemIssu 5 }
juniSystemIssuCriteriaEntry OBJECT-TYPE
SYNTAX JuniSystemIssuCriteriaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table entry describing the criteria for an ISSU initialization."
INDEX { juniSystemIssuCriteriaIndex }
::= { juniSystemIssuCriteriaTable 1 }
JuniSystemIssuCriteriaEntry ::= SEQUENCE {
juniSystemIssuCriteriaIndex Integer32,
juniSystemIssuCriteriaDescription DisplayString,
juniSystemIssuCriteriaStatus INTEGER }
juniSystemIssuCriteriaIndex OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index associated with an entry of the system ISSU Criteria Table."
::= { juniSystemIssuCriteriaEntry 1 }
juniSystemIssuCriteriaDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"To initialize ISSU, few criteria need to be met. If these criteria
were not met, ISSU cannot be initialized. This object provides the
criteria details."
::= { juniSystemIssuCriteriaEntry 2 }
juniSystemIssuCriteriaStatus OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
conditional(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"To initialize ISSU, few criteria need to be met. If these criteria
were not met, ISSU cannot be initialized. This object indicates
whether a criteria has met. It will be conditional when that the
user can choose to accept the consequences of proceeding with ISSU
with non-ideal operating conditions."
::= { juniSystemIssuCriteriaEntry 3 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notification control objects
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemMemUtilTrapEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the sending of primary system processor memory utilization
events. Setting the value of this object to true(1) will cause system
memory utilization event notifications, if they occur, to be sent to the
management entity on this system. Setting the value of this object to
false(2) will disable memory utilization event notifications."
DEFVAL { false }
::= { juniSystemGeneral 19 }
juniSystemReloadSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"In a juniSystemReloadCommand notification, this object indicates the
number of the slot that is being reloaded. Note that slot numbers are
zero-based."
::= { juniSystemGeneral 20 }
juniSystemUtilizationThresholdDirection OBJECT-TYPE
SYNTAX INTEGER {
rising(1),
falling(2) }
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The type of resource utilization notification being sent. See the
DESCRIPTIONs for the juniSystemUtilizationTable elements for details on
what conditions trigger a resource utilization notification."
::= { juniSystemGeneral 21 }
juniSystemUtilizationTrapEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the sending of system resource utilization threshold
notifications. Setting the value of this object to true(1) will allow
resource utilization threshold event notifications, if they occur, to be
sent to the management entity on this system. Setting the value of this
object to false(2) will disable resource utilization threshold
utilization event notifications."
DEFVAL { true }
::= { juniSystemGeneral 22 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Notifications
--
-- The juniSystemTrap OBJECT IDENTIFIER is used to define SNMPv2 notifications
-- that may be translated into SNMPv1 traps.
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemHighMemUtil NOTIFICATION-TYPE
OBJECTS {
juniSystemMemCapacity,
juniSystemMemUtilPct,
juniSystemAbatedMemUtilThreshold,
juniSystemHighMemUtilThreshold,
juniSystemMemKBytesCapacity }
STATUS current
DESCRIPTION
"Report system memory utilization has met the conditions of
juniSystemHighMemUtilThreshold. If the memory capacity is greater than
2147483647, a -1 value is returned in juniSystemMemCapacity, and the
actual memory capacity in units of 1024 bytes is returned in
juniSystemMemKBytesCapacity."
::= { juniSystemTrap 1 }
juniSystemAbatedMemUtil NOTIFICATION-TYPE
OBJECTS {
juniSystemMemCapacity,
juniSystemMemUtilPct,
juniSystemAbatedMemUtilThreshold,
juniSystemHighMemUtilThreshold,
juniSystemMemKBytesCapacity }
STATUS current
DESCRIPTION
"Reports system memory utilization has met the conditions of
juniSystemAbatedMemUtilThreshold. If the memory capacity is greater
than 2147483647, a -1 value is returned in juniSystemMemCapacity, and
the actual memory capacity in units of 1024 bytes is returned in
juniSystemMemKBytesCapacity."
::= { juniSystemTrap 2 }
juniSystemModuleOperStatusChange NOTIFICATION-TYPE
OBJECTS {
juniSystemModuleCurrentType,
juniSystemModuleAdminStatus,
juniSystemModuleOperStatus,
juniSystemModuleDisableReason,
juniSystemModuleDescr }
STATUS current
DESCRIPTION
"Reports a status change for a module. This trap is generated on a
transition into a stable state (online or disabled) or on a transition
out of online. If redundancy is supported for the module
(juniSystemModuleRedundancySupported is true(1)), then the
juniSystemModuleSpareServer and juniSystemModuleAssociatedSlot objects
are also included in the notification."
::= { juniSystemTrap 3 }
juniSystemPowerStatusChange NOTIFICATION-TYPE
OBJECTS {
entPhysicalDescr,
juniSystemPowerStatus }
STATUS current
DESCRIPTION
"Reports a change in the status of a power element."
::= { juniSystemTrap 4 }
juniSystemFanStatusChange NOTIFICATION-TYPE
OBJECTS {
entPhysicalDescr,
juniSystemFanStatus }
STATUS current
DESCRIPTION
"Reports a transition between the three states of the fan subsystem.
When the fan subsystem transitions to the failed state the Thermal
Protection hold off time begins."
::= { juniSystemTrap 5 }
juniSystemTempStatusChange NOTIFICATION-TYPE
OBJECTS {
juniSystemTempStatus }
STATUS current
DESCRIPTION
"Reports a change in the temperature status. When the status
transitions to the tooHigh state the system enters Thermal Protection
mode."
::= { juniSystemTrap 6 }
juniSystemTempProtectionStatusChange NOTIFICATION-TYPE
OBJECTS {
juniSystemTempProtectionStatus,
juniSystemTempProtectionHoldOffTimeRemaining }
STATUS current
DESCRIPTION
"Notification about changes in the state of Thermal Protection. This
notification is sent when the tempProtectionStatus changes. It is also
sent when the holdOffTimeRemaining is 50% of the holdOffTime."
::= { juniSystemTrap 7 }
juniSystemReloadCommand NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Notification indicating that a slot or the entire system is about to
restart due to a system console reload command. If the reload is only
on an individual slot then the following object is included in the
notification:
juniSystemReloadSlotNumber "
::= { juniSystemTrap 8 }
juniSystemUtilizationThreshold NOTIFICATION-TYPE
OBJECTS {
juniSystemUtilizationThresholdDirection,
juniSystemUtilizationMaxCapacity,
juniSystemUtilizationCurrentValue,
juniSystemUtilizationThresholdRising,
juniSystemUtilizationThresholdFalling,
juniSystemUtilizationHoldDownTime }
STATUS current
DESCRIPTION
"Notification indicating that a system resource's utilization has met
the conditions of juniSystemUtilizationThresholdDirection. See the
DESCRIPTIONs for the juniSystemUtilizationTable elements for details on
what conditions trigger a resource utilization notification."
::= { juniSystemTrap 9 }
juniSystemIssuStateChange NOTIFICATION-TYPE
OBJECTS {
juniSystemIssuState }
STATUS current
DESCRIPTION
"Notification about changes in the status, in case of ISSU upgrade.
This notification is sent when the juniSystemIssuState changes. The
trap parameter will indicate the current value of the
juniSystemIssuState.
This notification is supported on the second generation E-series
platform family (E320 & E120) from 9.0 release onwards. This
object is also supported on ERX-1440 in JUNOSe 9.2 and
subsequent system releases."
::= { juniSystemTrap 10 }
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Conformance information
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
juniSystemCompliances OBJECT IDENTIFIER ::= { juniSystemConformance 1 }
juniSystemGroups OBJECT IDENTIFIER ::= { juniSystemConformance 2 }
--
-- compliance statements
--
juniSystemCompliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities that implement the Juniper
E-series System MIB. This statement became obsolete when system
resource utilization support was added."
MODULE -- this module
MANDATORY-GROUPS {
juniSystemGeneralGroup,
juniSystemSubsystemGroup,
juniSystemModuleGroup,
juniSystemPortGroup,
juniSystemTimingGroup,
juniSystemFabricGroup,
juniSystemNvsGroup,
juniSystemPowerGroup,
juniSystemTemperatureGroup,
juniSystemNotificationObjectsGroup,
juniSystemNotificationGroup }
::= { juniSystemCompliances 1 } -- JUNOSe 4.1
juniSystemCompliance2 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities that implement the Juniper
E-series System MIB. This statement became obsolete when the system
resource utilization trap enabled and the KByte memory capacilty objects
were added."
MODULE -- this module
MANDATORY-GROUPS {
juniSystemGeneralGroup,
juniSystemSubsystemGroup,
juniSystemModuleGroup,
juniSystemPortGroup,
juniSystemTimingGroup,
juniSystemFabricGroup,
juniSystemNvsGroup,
juniSystemPowerGroup,
juniSystemTemperatureGroup,
juniSystemUtilizationGroup,
juniSystemNotificationObjectsGroup,
juniSystemNotificationGroup2 }
OBJECT juniSystemUtilizationMaxCapacity
MIN-ACCESS accessible-for-notify
DESCRIPTION
"This object is only required to be included in the
juniSystemUtilizationThreshold notifications."
OBJECT juniSystemUtilizationCurrentValue
MIN-ACCESS accessible-for-notify
DESCRIPTION
"This object is only required to be included in the
juniSystemUtilizationThreshold notifications."
OBJECT juniSystemUtilizationThresholdRising
MIN-ACCESS accessible-for-notify
DESCRIPTION
"This object may have a fixed value in a particular
implementation and is therefore only required to be included
in the juniSystemUtilizationThreshold notifications."
OBJECT juniSystemUtilizationThresholdFalling
MIN-ACCESS accessible-for-notify
DESCRIPTION
"This object may have a fixed value in a particular
implementation and is therefore only required to be included
in the juniSystemUtilizationThreshold notifications."
OBJECT juniSystemUtilizationHoldDownTime
MIN-ACCESS accessible-for-notify
DESCRIPTION
"This object may have a fixed value in a particular
implementation and is therefore only required to be included
in the juniSystemUtilizationThreshold notifications."
::= { juniSystemCompliances 2 } -- JUNOSe 5.0
juniSystemCompliance3 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities that implement the Juniper
E-series System MIB. This statement became obsolete when the module
level span object was added."
MODULE -- this module
MANDATORY-GROUPS {
juniSystemGeneralGroup2,
juniSystemSubsystemGroup,
juniSystemModuleGroup,
juniSystemPortGroup,
juniSystemTimingGroup,
juniSystemFabricGroup,
juniSystemNvsGroup,
juniSystemPowerGroup,
juniSystemTemperatureGroup,
juniSystemUtilizationGroup,
juniSystemNotificationObjectsGroup,
juniSystemNotificationGroup2 }
::= { juniSystemCompliances 3 } -- JUNOSe 5.2
juniSystemCompliance4 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities that implement the Juniper
E-series System MIB."
MODULE -- this module
MANDATORY-GROUPS {
juniSystemGeneralGroup2,
juniSystemSubsystemGroup,
juniSystemModuleGroup2,
juniSystemPortGroup,
juniSystemTimingGroup,
juniSystemFabricGroup,
juniSystemNvsGroup,
juniSystemPowerGroup,
juniSystemTemperatureGroup,
juniSystemUtilizationGroup,
juniSystemNotificationObjectsGroup,
juniSystemNotificationGroup2 }
::= { juniSystemCompliances 4 } -- JUNOSe 6.0
juniSystemCompliance5 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"Obsolete compliance statement for entities that implement the Juniper
E-series System MIB."
MODULE -- this module
MANDATORY-GROUPS {
juniSystemGeneralGroup2,
juniSystemSubsystemGroup,
juniSystemModuleGroup2,
juniSystemPortGroup,
juniSystemTimingGroup,
juniSystemFabricGroup,
juniSystemNvsGroup,
juniSystemPowerGroup,
juniSystemTemperatureGroup,
juniSystemUtilizationGroup2,
juniSystemNotificationObjectsGroup,
juniSystemNotificationGroup2 }
::= { juniSystemCompliances 5 } -- JUNOSe 7.3
juniSystemCompliance6 MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for entities that implement the Juniper
E-series System MIB."
MODULE -- this module
MANDATORY-GROUPS {
juniSystemGeneralGroup2,
juniSystemSubsystemGroup,
juniSystemModuleGroup3,
juniSystemPortGroup,
juniSystemTimingGroup,
juniSystemFabricGroup,
juniSystemNvsGroup,
juniSystemPowerGroup,
juniSystemTemperatureGroup,
juniSystemUtilizationGroup2,
juniSystemNotificationObjectsGroup,
juniSystemNotificationGroup2 }
::= { juniSystemCompliances 6 } -- JUNOSe 8.0
juniSystemCompliance7 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities that implement the Juniper
E-series System MIB."
MODULE -- this module
MANDATORY-GROUPS {
juniSystemGeneralGroup2,
juniSystemSubsystemGroup,
juniSystemModuleGroup3,
juniSystemPortGroup,
juniSystemTimingGroup,
juniSystemFabricGroup,
juniSystemNvsGroup,
juniSystemPowerGroup,
juniSystemTemperatureGroup,
juniSystemUtilizationGroup2,
juniSystemNotificationObjectsGroup,
juniSystemIssuGroup,
juniSystemNotificationGroup3 }
::= { juniSystemCompliances 7 } -- JUNOSe 9.0
--
-- units of conformance
--
juniSystemGeneralGroup OBJECT-GROUP
OBJECTS {
juniSystemSwVersion,
juniSystemSwBuildDate,
juniSystemMemUtilPct,
juniSystemMemCapacity,
juniSystemHighMemUtilThreshold,
juniSystemAbatedMemUtilThreshold,
juniSystemMemUtilTrapEnable,
juniSystemBootConfigControl,
juniSystemBootBackupConfigControl,
juniSystemBootForceBackupControl,
juniSystemBootAutoRevertControl,
juniSystemBootAutoRevertCountTolerance,
juniSystemBootAutoRevertTimeTolerance,
juniSystemBootReleaseFile,
juniSystemBootConfigFile,
juniSystemBootBackupReleaseFile,
juniSystemBootBackupConfigFile,
juniSystemRedundancyRevertControl,
juniSystemRedundancyRevertTimeOfDay }
STATUS obsolete
DESCRIPTION
"Obsolete collection of management objects providing system-wide
software status and control information in a Juniper E-series product.
This group became obsolete when the system resource utilization
threshold trap enable/disable and the KByte memory capacilty objects
were added."
::= { juniSystemGroups 1 } -- JUNOSe 4.1
juniSystemSubsystemGroup OBJECT-GROUP
OBJECTS {
juniSystemSubsystemName,
juniSystemSubsystemBootReleaseFile,
juniSystemSubsystemBootBackupReleaseFile }
STATUS current
DESCRIPTION
"A collection of management objects providing subsystem software control
information in a Juniper E-series product."
::= { juniSystemGroups 2 } -- JUNOSe 4.1
juniSystemModuleGroup OBJECT-GROUP
OBJECTS {
juniSystemMaxSlotNumber,
juniSystemMaxModulesPerSlot,
juniSystemSlotStatus,
juniSystemSlotType,
juniSystemModuleOperStatus,
juniSystemModuleDisableReason,
juniSystemModuleLastChange,
juniSystemModuleCurrentType,
juniSystemModuleExpectedType,
juniSystemModuleDescr,
juniSystemModuleSlotSpan,
juniSystemModulePortCount,
juniSystemModuleSerialNumber,
juniSystemModuleAssemblyPartNumber,
juniSystemModuleAssemblyRev,
juniSystemModulePhysicalIndex,
juniSystemModuleSoftwareSupport,
juniSystemModuleRedundancySupport,
juniSystemModuleSoftwareVersion,
juniSystemModuleCpuUtilPct,
juniSystemModuleMemUtilPct,
juniSystemModuleAdminStatus,
juniSystemModuleControl,
juniSystemModuleBootReleaseFile,
juniSystemModuleBootBackupReleaseFile,
juniSystemModuleRedundancyGroupId,
juniSystemModuleRedundancySpare,
juniSystemModuleRedundancyAssociatedSlot,
juniSystemModuleRedundancyLockout,
juniSystemModuleRedundancyRevertControl,
juniSystemModuleRedundancyRevertTime }
STATUS obsolete
DESCRIPTION
"Obsolete collection of management objects that provide system module
information in a Juniper E-series product. This group became obsolete
when the module level span object was added."
::= { juniSystemGroups 3 } -- JUNOSe 4.1
juniSystemPortGroup OBJECT-GROUP
OBJECTS {
juniSystemPortPhysicalIndex,
juniSystemPortIfIndex }
STATUS current
DESCRIPTION
"A collection of management objects providing physical I/O port
information in a Juniper E-series product."
::= { juniSystemGroups 4 } -- JUNOSe 4.1
juniSystemTimingGroup OBJECT-GROUP
OBJECTS {
juniSystemAdminTimingSource,
juniSystemOperTimingSource,
juniSystemTimingAutoUpgrade,
juniSystemTimingSourceType,
juniSystemTimingSourceIfIndex,
juniSystemTimingSourceLine,
juniSystemTimingWorkingStatus,
juniSystemTimingProtectedStatus }
STATUS current
DESCRIPTION
"A collection of management objects providing system timing source
information in a Juniper E-series product."
::= { juniSystemGroups 5 } -- JUNOSe 4.1
juniSystemFabricGroup OBJECT-GROUP
OBJECTS {
juniSystemFabricSpeed,
juniSystemFabricRev }
STATUS current
DESCRIPTION
"A collection of management objects providing system fabric information
in a Juniper E-series product."
::= { juniSystemGroups 6 } -- JUNOSe 4.1
juniSystemNvsGroup OBJECT-GROUP
OBJECTS {
juniSystemNvsCount,
juniSystemNvsPhysicalIndex,
juniSystemNvsStatus,
juniSystemNvsCapacity,
juniSystemNvsUtilPct }
STATUS current
DESCRIPTION
"A collection of management objects providing system non-volatile
storage (NVS) information in a Juniper E-series product."
::= { juniSystemGroups 7 } -- JUNOSe 4.1
juniSystemPowerGroup OBJECT-GROUP
OBJECTS {
juniSystemPowerCount,
juniSystemPowerPhysicalIndex,
juniSystemPowerStatus }
STATUS current
DESCRIPTION
"A collection of management objects providing system power element
information in a Juniper E-series product."
::= { juniSystemGroups 8 } -- JUNOSe 4.1
juniSystemTemperatureGroup OBJECT-GROUP
OBJECTS {
juniSystemFanCount,
juniSystemFanPhysicalIndex,
juniSystemFanStatus,
juniSystemTempCount,
juniSystemTempStatus,
juniSystemTempValue,
juniSystemTempPhysicalIndex,
juniSystemTempProtectionStatus,
juniSystemTempProtectionHoldOffTime,
juniSystemTempProtectionHoldOffTimeRemaining }
STATUS current
DESCRIPTION
"A collection of management objects providing system temperature control
information in a Juniper E-series product."
::= { juniSystemGroups 9 } -- JUNOSe 4.1
juniSystemNotificationObjectsGroup OBJECT-GROUP
OBJECTS {
juniSystemReloadSlotNumber }
STATUS current
DESCRIPTION
"A collection of management objects providing system information for
notification in a Juniper E-series product."
::= { juniSystemGroups 10 } -- JUNOSe 4.1
juniSystemNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
juniSystemHighMemUtil,
juniSystemAbatedMemUtil,
juniSystemModuleOperStatusChange,
juniSystemPowerStatusChange,
juniSystemFanStatusChange,
juniSystemTempStatusChange,
juniSystemTempProtectionStatusChange,
juniSystemReloadCommand }
STATUS obsolete
DESCRIPTION
"Obsolete collection of notifications for system events in a Juniper
E-series product. This group became obsolete when the system resource
utilization notification was added."
::= { juniSystemGroups 11 } -- JUNOSe 4.1
juniSystemUtilizationGroup OBJECT-GROUP
OBJECTS {
juniSystemUtilizationMaxCapacity,
juniSystemUtilizationCurrentValue,
juniSystemUtilizationThresholdRising,
juniSystemUtilizationThresholdFalling,
juniSystemUtilizationHoldDownTime,
juniSystemUtilizationThresholdDirection }
STATUS obsolete
DESCRIPTION
"Obsolete collection of management objects providing system resource
utilization information and notification control for a Juniper E-series
product."
::= { juniSystemGroups 12 } -- JUNOSe 5.0
juniSystemNotificationGroup2 NOTIFICATION-GROUP
NOTIFICATIONS {
juniSystemHighMemUtil,
juniSystemAbatedMemUtil,
juniSystemModuleOperStatusChange,
juniSystemPowerStatusChange,
juniSystemFanStatusChange,
juniSystemTempStatusChange,
juniSystemTempProtectionStatusChange,
juniSystemReloadCommand,
juniSystemUtilizationThreshold }
STATUS obsolete
DESCRIPTION
"A collection of notifications for system events in a Juniper E-series
product."
::= { juniSystemGroups 13 } -- JUNOSe 5.0
juniSystemGeneralGroup2 OBJECT-GROUP
OBJECTS {
juniSystemSwVersion,
juniSystemSwBuildDate,
juniSystemMemUtilPct,
juniSystemMemCapacity,
juniSystemMemKBytesCapacity,
juniSystemHighMemUtilThreshold,
juniSystemAbatedMemUtilThreshold,
juniSystemMemUtilTrapEnable,
juniSystemUtilizationTrapEnable,
juniSystemBootConfigControl,
juniSystemBootBackupConfigControl,
juniSystemBootForceBackupControl,
juniSystemBootAutoRevertControl,
juniSystemBootAutoRevertCountTolerance,
juniSystemBootAutoRevertTimeTolerance,
juniSystemBootReleaseFile,
juniSystemBootConfigFile,
juniSystemBootBackupReleaseFile,
juniSystemBootBackupConfigFile,
juniSystemRedundancyRevertControl,
juniSystemRedundancyRevertTimeOfDay }
STATUS current
DESCRIPTION
"A collection of management objects providing system-wide software
status and control information in a Juniper E-series product."
::= { juniSystemGroups 14 } -- JUNOSe 5.2
juniSystemModuleGroup2 OBJECT-GROUP
OBJECTS {
juniSystemMaxSlotNumber,
juniSystemMaxModulesPerSlot,
juniSystemSlotStatus,
juniSystemSlotType,
juniSystemModuleOperStatus,
juniSystemModuleDisableReason,
juniSystemModuleLastChange,
juniSystemModuleCurrentType,
juniSystemModuleExpectedType,
juniSystemModuleDescr,
juniSystemModuleSlotSpan,
juniSystemModulePortCount,
juniSystemModuleSerialNumber,
juniSystemModuleAssemblyPartNumber,
juniSystemModuleAssemblyRev,
juniSystemModulePhysicalIndex,
juniSystemModuleSoftwareSupport,
juniSystemModuleRedundancySupport,
juniSystemModuleLevelSpan,
juniSystemModuleSoftwareVersion,
juniSystemModuleCpuUtilPct,
juniSystemModuleMemUtilPct,
juniSystemModuleAdminStatus,
juniSystemModuleControl,
juniSystemModuleBootReleaseFile,
juniSystemModuleBootBackupReleaseFile,
juniSystemModuleRedundancyGroupId,
juniSystemModuleRedundancySpare,
juniSystemModuleRedundancyAssociatedSlot,
juniSystemModuleRedundancyLockout,
juniSystemModuleRedundancyRevertControl,
juniSystemModuleRedundancyRevertTime }
STATUS obsolete
DESCRIPTION
"A collection of management objects that provide system module
information in a Juniper E-series product."
::= { juniSystemGroups 15 } -- JUNOSe 6.0
juniSystemUtilizationGroup2 OBJECT-GROUP
OBJECTS {
juniSystemUtilizationMaxCapacity,
juniSystemUtilizationCurrentValue,
juniSystemUtilizationThresholdRising,
juniSystemUtilizationThresholdFalling,
juniSystemUtilizationHoldDownTime,
juniSystemUtilizationThresholdDirection,
juniSystemCpuUtilizationTaskName,
juniSystemCpuUtilizationInvoked,
juniSystemCpuUtilizationInvokationPerSec,
juniSystemCpuUtilizationTotalRunningTime,
juniSystemCpuUtilizationPercentageRunningTime,
juniSystemCpuUtilizationAverageTimePerInvokation,
juniSystemCpuUtilizationFiveSecondUtilization,
juniSystemCpuUtilizationOneMinuteUtilization,
juniSystemCpuUtilizationFiveMinuteUtilization,
juniSystemCpuUtilizationNumberOfInstances }
STATUS current
DESCRIPTION
"A collection of management objects providing system resource
utilization information and notification control for a Juniper E-series
product."
::= { juniSystemGroups 16 } -- JUNOSe 7.3
juniSystemModuleGroup3 OBJECT-GROUP
OBJECTS {
juniSystemMaxSlotNumber,
juniSystemMaxModulesPerSlot,
juniSystemSlotStatus,
juniSystemSlotType,
juniSystemModuleOperStatus,
juniSystemModuleDisableReason,
juniSystemModuleLastChange,
juniSystemModuleCurrentType,
juniSystemModuleExpectedType,
juniSystemModuleDescr,
juniSystemModuleSlotSpan,
juniSystemModulePortCount,
juniSystemModuleSerialNumber,
juniSystemModuleAssemblyPartNumber,
juniSystemModuleAssemblyRev,
juniSystemModulePhysicalIndex,
juniSystemModuleSoftwareSupport,
juniSystemModuleRedundancySupport,
juniSystemModuleLevelSpan,
juniSystemModuleSoftwareVersion,
juniSystemModuleCpuUtilPct,
juniSystemModuleMemUtilPct,
juniSystemModuleAdminStatus,
juniSystemModuleControl,
juniSystemModuleBootReleaseFile,
juniSystemModuleBootBackupReleaseFile,
juniSystemModuleCpuFiveSecUtilPct,
juniSystemModuleCpuOneMinAvgPct,
juniSystemModuleCpuFiveMinAvgPct,
juniSystemModuleRedundancyGroupId,
juniSystemModuleRedundancySpare,
juniSystemModuleRedundancyAssociatedSlot,
juniSystemModuleRedundancyLockout,
juniSystemModuleRedundancyRevertControl,
juniSystemModuleRedundancyRevertTime }
STATUS current
DESCRIPTION
"A collection of management objects that provide system module
information in a Juniper E-series product."
::= { juniSystemGroups 17 } -- JUNOSe 8.0
juniSystemIssuGroup OBJECT-GROUP
OBJECTS {
juniSystemIssuState,
juniSystemIssuArmedReleaseFile,
juniSystemIssuRunningReleaseFile,
juniSystemIssuStatus,
juniSystemIssuCriteriaDescription,
juniSystemIssuCriteriaStatus }
STATUS current
DESCRIPTION
"A collection of management objects that provide ISSU related
information in a Juniper E-series product."
::= { juniSystemGroups 18 } -- JUNOSe 9.0
juniSystemNotificationGroup3 NOTIFICATION-GROUP
NOTIFICATIONS {
juniSystemHighMemUtil,
juniSystemAbatedMemUtil,
juniSystemModuleOperStatusChange,
juniSystemPowerStatusChange,
juniSystemFanStatusChange,
juniSystemTempStatusChange,
juniSystemTempProtectionStatusChange,
juniSystemReloadCommand,
juniSystemUtilizationThreshold,
juniSystemIssuStateChange }
STATUS current
DESCRIPTION
"A collection of notifications for system events in a Juniper E-series
product."
::= { juniSystemGroups 19 } -- JUNOSe 9.0
END