LINKSYS-openflow-MIB DEFINITIONS ::= BEGIN
-- Title: LINKSYS open flow Configuration
-- Version: 7.50.00.00
-- Date: 24-November-2010
-- E-mail: yahal@linksys.com
--
IMPORTS
TruthValue, TEXTUAL-CONVENTION, TimeStamp,
DisplayString, DateAndTime, RowStatus FROM SNMPv2-TC
TimeTicks, IpAddress, NOTIFICATION-TYPE,
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32 FROM SNMPv2-SMI
rnd FROM LINKSYS-MIB;
rlOpenFlow OBJECT IDENTIFIER ::= { rnd 319 }
-------------------------------------------------------------------------------
rlOpenFlowSupported OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Open Flow support in the switch."
::= { rlOpenFlow 1 }
-------------------------------------------------------------------------------
rlOpenFlowTcpPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Open Flow TCP port."
DEFVAL { 6633 }
::= { rlOpenFlow 2 }
-------------------------------------------------------------------------------
rlOpenFlowServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Open Flow server IP address."
DEFVAL {'00000000'H}
::= { rlOpenFlow 3 }
-------------------------------------------------------------------------------
rlOpenFlowProtocolType OBJECT-TYPE
SYNTAX INTEGER {
tcp(0),
tls(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "OpenFlow protocol. tls or tcp.
The default value is tcp."
DEFVAL{ tcp }
::= { rlOpenFlow 4 }
-------------------------------------------------------------------------------
rlOpenFlowDefaultForwardAction OBJECT-TYPE
SYNTAX INTEGER {
forward(0),
drop(1),
toController(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "OpenFlow Forward Action to controller.
forward, drop or toController.
The default value is forward."
DEFVAL{ forward }
::= { rlOpenFlow 5 }
-------------------------------------------------------------------------------
rlOpenFlowEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OpenFlow global enable mode."
::= { rlOpenFlow 6 }
-------------------------------------------------------------------------------
rlOpenFlowEnableAfterReset OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OpenFlow global enable mode after reset."
DEFVAL { false }
::= { rlOpenFlow 7 }
END