mibs/MIBS/opengear/OG-STATUS-MIB

901 lines
21 KiB
Plaintext
Raw Normal View History

2023-12-05 12:25:34 +01:00
-- =====================================================================
-- == OG-STATUS-MIB: ==
-- == Opengear status Management Information Base ==
-- == ==
-- == (c) Copyright 2010-2014 Opengear Inc. ==
-- =====================================================================
OG-STATUS-MIB DEFINITIONS ::= BEGIN
IMPORTS
opengear
FROM OG-SMI-MIB
MODULE-IDENTITY, OBJECT-TYPE
FROM SNMPv2-SMI
Integer32
FROM SNMPv2-SMI
Counter64
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
DisplayString
FROM SNMPv2-TC;
ogStatus MODULE-IDENTITY
LAST-UPDATED "201308160000Z"
ORGANIZATION "Opengear Inc."
CONTACT-INFO
"Opengear Inc.
630 West 9560 South, Suite A,
Sandy, UT 84070
support@opengear.com"
DESCRIPTION
"Legacy Opengear status and alert MIB"
REVISION "201308160000Z"
DESCRIPTION
"Add UPS RPC outlet tables add extra stats for serial ports."
REVISION "201308110000Z"
DESCRIPTION
"Add DIO tables for status and current alerts."
REVISION "201008150000Z"
DESCRIPTION
"Fix type mismatch for serial signal states."
REVISION "201001110000Z"
DESCRIPTION
"Initial revision"
::= { opengear 16 }
ogSerialPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's serial port statistics table."
::= { ogStatus 1 }
ogSerialPortStatusEntry OBJECT-TYPE
SYNTAX SerialPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A console serial port entry"
INDEX { ogSerialPortStatusIndex }
::= { ogSerialPortStatusTable 1 }
SerialPortStatusEntry ::= SEQUENCE {
ogSerialPortStatusIndex Integer32,
ogSerialPortStatusPort Integer32,
ogSerialPortStatusRxBytes Counter64,
ogSerialPortStatusTxBytes Counter64,
ogSerialPortStatusSpeed Integer32,
ogSerialPortStatusDCD INTEGER,
ogSerialPortStatusDTR INTEGER,
ogSerialPortStatusDSR INTEGER,
ogSerialPortStatusCTS INTEGER,
ogSerialPortStatusRTS INTEGER,
ogSerialPortStatusLabel DisplayString
}
ogSerialPortStatusIndex OBJECT-TYPE
SYNTAX Integer32(0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the serial port table of this status"
::= { ogSerialPortStatusEntry 1 }
ogSerialPortStatusPort OBJECT-TYPE
SYNTAX Integer32(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port number"
::= { ogSerialPortStatusEntry 2 }
ogSerialPortStatusRxBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port bytes received"
::= { ogSerialPortStatusEntry 3 }
ogSerialPortStatusTxBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port bytes transmitted"
::= { ogSerialPortStatusEntry 4 }
ogSerialPortStatusSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port speed in bits per second"
::= { ogSerialPortStatusEntry 5 }
ogSerialPortStatusDCD OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the DCD signal."
::= { ogSerialPortStatusEntry 6 }
ogSerialPortStatusDTR OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the DTR signal."
::= { ogSerialPortStatusEntry 7 }
ogSerialPortStatusDSR OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the DSR signal."
::= { ogSerialPortStatusEntry 8 }
ogSerialPortStatusCTS OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the CTS signal."
::= { ogSerialPortStatusEntry 9 }
ogSerialPortStatusRTS OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the RTS signal."
::= { ogSerialPortStatusEntry 10 }
ogSerialPortStatusLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The label of the port"
::= { ogSerialPortStatusEntry 11 }
ogSerialPortActiveUsersTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialPortActiveUsersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's serial port users table."
::= { ogStatus 2 }
ogSerialPortActiveUsersEntry OBJECT-TYPE
SYNTAX SerialPortActiveUsersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A user logged in on the serial port"
INDEX { ogSerialPortActiveUsersIndex }
::= { ogSerialPortActiveUsersTable 1 }
SerialPortActiveUsersEntry ::= SEQUENCE {
ogSerialPortActiveUsersIndex Integer32,
ogSerialPortActiveUsersPort Integer32,
ogSerialPortActiveUsersName DisplayString,
ogSerialPortActiveUsersPortLabel DisplayString
}
ogSerialPortActiveUsersIndex OBJECT-TYPE
SYNTAX Integer32(0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the serial port active users table"
::= { ogSerialPortActiveUsersEntry 1 }
ogSerialPortActiveUsersPort OBJECT-TYPE
SYNTAX Integer32(1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port number"
::= { ogSerialPortActiveUsersEntry 2 }
ogSerialPortActiveUsersName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the user logged in on the port."
::= { ogSerialPortActiveUsersEntry 3 }
ogSerialPortActiveUsersPortLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The label of the port being accessed"
::= { ogSerialPortActiveUsersEntry 4 }
ogRpcStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpcStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's RPC table."
::= { ogStatus 3 }
ogRpcStatusEntry OBJECT-TYPE
SYNTAX RpcStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RPC status entry"
INDEX { ogRpcStatusIndex }
::= { ogRpcStatusTable 1 }
RpcStatusEntry ::= SEQUENCE {
ogRpcStatusIndex Integer32,
ogRpcStatusName DisplayString,
ogRpcStatusMaxTemp Integer32,
ogRpcStatusAlertCount Integer32
}
ogRpcStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the RPC status table"
::= { ogRpcStatusEntry 1 }
ogRpcStatusName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the RPC device."
::= { ogRpcStatusEntry 2 }
ogRpcStatusMaxTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum temperature on the RPC"
::= { ogRpcStatusEntry 3 }
ogRpcStatusAlertCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of alerts triggered on the RPC"
::= { ogRpcStatusEntry 4 }
ogEmdStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmdStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's EMD table."
::= { ogStatus 4 }
ogEmdStatusEntry OBJECT-TYPE
SYNTAX EmdStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EMD status entry"
INDEX { ogEmdStatusIndex }
::= { ogEmdStatusTable 1 }
EmdStatusEntry ::= SEQUENCE {
ogEmdStatusIndex Integer32,
ogEmdStatusName DisplayString,
ogEmdStatusTemp Integer32,
ogEmdStatusHumidity Integer32,
ogEmdStatusAlertCount Integer32
}
ogEmdStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the EMD status table"
::= { ogEmdStatusEntry 1 }
ogEmdStatusName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the EMD device."
::= { ogEmdStatusEntry 2 }
ogEmdStatusTemp OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current temperature on the EMD"
::= { ogEmdStatusEntry 3 }
ogEmdStatusHumidity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Humidity sensor on the EMD"
::= { ogEmdStatusEntry 4 }
ogEmdStatusAlertCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of alerts triggered on the EMD"
::= { ogEmdStatusEntry 5 }
ogDioStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DioStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ths Digital I/O status table."
::= { ogStatus 5 }
ogDioStatusEntry OBJECT-TYPE
SYNTAX DioStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Digital I/O status entry"
INDEX { ogDioStatusIndex }
::= { ogDioStatusTable 1 }
DioStatusEntry ::= SEQUENCE {
ogDioStatusIndex Integer32,
ogDioStatusName DisplayString,
ogDioStatusType INTEGER,
ogDioStatusDirection INTEGER,
ogDioStatusState INTEGER,
ogDioStatusCounter Counter64,
ogDioStatusTriggerMode INTEGER
}
ogDioStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the Digital I/O status table"
::= { ogDioStatusEntry 1 }
ogDioStatusName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of this Digital I/O."
::= { ogDioStatusEntry 2 }
ogDioStatusType OBJECT-TYPE
SYNTAX INTEGER {
ttlInputOutput(0),
highVoltageOutput(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Digital I/O type (TTL Input/Output or High-Voltage Output)."
::= { ogDioStatusEntry 3 }
ogDioStatusDirection OBJECT-TYPE
SYNTAX INTEGER {
output(0),
input(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of the Digital I/O (Input or Output)"
::= { ogDioStatusEntry 4 }
ogDioStatusState OBJECT-TYPE
SYNTAX INTEGER {
low(0),
high(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The electrical state value of the Digital I/O (Low or High)"
::= { ogDioStatusEntry 5 }
ogDioStatusCounter OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The trigger counter of this Digital I/O"
::= { ogDioStatusEntry 6 }
ogDioStatusTriggerMode OBJECT-TYPE
SYNTAX INTEGER {
invalid(0),
risingEdge(1),
fallingEdge(2),
risingFallingEdge(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Trigger Mode of the Digital I/O"
::= { ogDioStatusEntry 7 }
-- alert status
ogSignalAlertStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SignalAlertStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's serial port signal table."
::= { ogStatus 6 }
ogSignalAlertStatusEntry OBJECT-TYPE
SYNTAX SignalAlertStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A console signal entry"
INDEX { ogSignalAlertStatusIndex }
::= { ogSignalAlertStatusTable 1 }
SignalAlertStatusEntry ::= SEQUENCE {
ogSignalAlertStatusIndex Integer32,
ogSignalAlertStatusPort Integer32,
ogSignalAlertStatusLabel DisplayString,
ogSignalAlertStatusSignalName DisplayString,
ogSignalAlertStatusState INTEGER
}
ogSignalAlertStatusIndex OBJECT-TYPE
SYNTAX Integer32(0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the signal table of this alert"
::= { ogSignalAlertStatusEntry 1 }
ogSignalAlertStatusPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port number on which the signal change occurred"
::= { ogSignalAlertStatusEntry 2 }
ogSignalAlertStatusLabel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The label for the serial port where the signal applies."
::= { ogSignalAlertStatusEntry 3 }
ogSignalAlertStatusSignalName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The particular signal which changed"
::= { ogSignalAlertStatusEntry 4 }
ogSignalAlertStatusState OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal state"
::= { ogSignalAlertStatusEntry 5 }
ogEnvAlertStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnvAlertStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's serial port signal table."
::= { ogStatus 7 }
ogEnvAlertStatusEntry OBJECT-TYPE
SYNTAX EnvAlertStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A console environment entry"
INDEX { ogEnvAlertStatusIndex }
::= { ogEnvAlertStatusTable 1 }
EnvAlertStatusEntry ::= SEQUENCE {
ogEnvAlertStatusIndex Integer32,
ogEnvAlertStatusDevice DisplayString,
ogEnvAlertStatusSensor DisplayString,
ogEnvAlertStatusOutlet Integer32,
ogEnvAlertStatusValue Integer32,
ogEnvAlertStatusOldValue Integer32,
ogEnvAlertStatusStatus Integer32
}
ogEnvAlertStatusIndex OBJECT-TYPE
SYNTAX Integer32(0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the environment alert status"
::= { ogEnvAlertStatusEntry 1 }
ogEnvAlertStatusDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The device the environment alert occurred on."
::= { ogEnvAlertStatusEntry 2 }
ogEnvAlertStatusSensor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sensor the environment alert occurred on."
::= { ogEnvAlertStatusEntry 3 }
ogEnvAlertStatusOutlet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Outlet of the environment status"
::= { ogEnvAlertStatusEntry 4 }
ogEnvAlertStatusValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of the environment status"
::= { ogEnvAlertStatusEntry 5 }
ogEnvAlertStatusOldValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Previous value of the environment status"
::= { ogEnvAlertStatusEntry 6 }
ogEnvAlertStatusStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"status value of the environment status"
::= { ogEnvAlertStatusEntry 7 }
ogNutAlertStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF NutAlertStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's NUT (UPS) alert table."
::= { ogStatus 8 }
ogNutAlertStatusEntry OBJECT-TYPE
SYNTAX NutAlertStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A NUT (UPS) entry"
INDEX { ogNutAlertStatusIndex }
::= { ogNutAlertStatusTable 1 }
NutAlertStatusEntry ::= SEQUENCE {
ogNutAlertStatusIndex Integer32,
ogNutAlertStatusPort Integer32,
ogNutAlertStatusName DisplayString,
ogNutAlertStatusHost DisplayString,
ogNutAlertStatusStatus DisplayString
}
ogNutAlertStatusIndex OBJECT-TYPE
SYNTAX Integer32(0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the NUT (UPS) alert status"
::= { ogNutAlertStatusEntry 1 }
ogNutAlertStatusPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port of the NUT (UPS) alert"
::= { ogNutAlertStatusEntry 2 }
ogNutAlertStatusName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the NUT (UPS) alert."
::= { ogNutAlertStatusEntry 3 }
ogNutAlertStatusHost OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The host of the NUT (UPS) alert."
::= { ogNutAlertStatusEntry 4 }
ogNutAlertStatusStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the NUT (UPS) alert."
::= { ogNutAlertStatusEntry 5 }
ogDataAlertStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DataAlertStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Data Usage alert table."
::= { ogStatus 9 }
ogDataAlertStatusEntry OBJECT-TYPE
SYNTAX DataAlertStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Data Usage entry"
INDEX { ogDataAlertStatusIndex }
::= { ogDataAlertStatusTable 1 }
DataAlertStatusEntry ::= SEQUENCE {
ogDataAlertStatusIndex Integer32,
ogDataAlertStatusBytes Integer32,
ogDataAlertStatusSeconds Integer32,
ogDataAlertStatusDevice DisplayString,
ogDataAlertStatusState INTEGER
}
ogDataAlertStatusIndex OBJECT-TYPE
SYNTAX Integer32(0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the data usage alert"
::= { ogDataAlertStatusEntry 1 }
ogDataAlertStatusBytes OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes exceeded during the time period"
::= { ogDataAlertStatusEntry 2 }
ogDataAlertStatusSeconds OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time in seconds over which the number of bytes was exceeded"
::= { ogDataAlertStatusEntry 3 }
ogDataAlertStatusDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique name for the interface the alert occurred on."
::= { ogDataAlertStatusEntry 4 }
ogDataAlertStatusState OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the data alert."
::= { ogDataAlertStatusEntry 5 }
ogDioAlertStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DioAlertStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ths Digital I/O current alert table."
::= { ogStatus 10 }
ogDioAlertStatusEntry OBJECT-TYPE
SYNTAX DioAlertStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Digital I/O current alert entry"
INDEX { ogDioAlertStatusIndex }
::= { ogDioAlertStatusTable 1 }
DioAlertStatusEntry ::= SEQUENCE {
ogDioAlertStatusIndex Integer32,
ogDioAlertStatusName DisplayString,
ogDioAlertStatusValue INTEGER,
ogDioAlertStatusOldValue INTEGER,
ogDioAlertStatusTriggered INTEGER
}
ogDioAlertStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the Digital I/O Input alert table"
::= { ogDioAlertStatusEntry 1 }
ogDioAlertStatusName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Digital I/O Input which the alert occurred on."
::= { ogDioAlertStatusEntry 2 }
ogDioAlertStatusValue OBJECT-TYPE
SYNTAX INTEGER {
open(0),
closed(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current value of the Digital I/O Input (Open or Closed)"
::= { ogDioAlertStatusEntry 3 }
ogDioAlertStatusOldValue OBJECT-TYPE
SYNTAX INTEGER {
open(0),
closed(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Previous value of the Digital I/O Input (Open or Closed)"
::= { ogDioAlertStatusEntry 4 }
ogDioAlertStatusTriggered OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Trigger status value of the Digital I/O"
::= { ogDioAlertStatusEntry 5 }
-- end alert status
-- conformance information
ogStatusConformance OBJECT IDENTIFIER ::= { ogStatus 65535 }
ogStatusCompliances OBJECT IDENTIFIER ::= { ogStatusConformance 1 }
ogStatusGroups OBJECT IDENTIFIER ::= { ogStatusConformance 2 }
-- compliance statements
ogStatusCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the Opengear status MIB."
MODULE -- this module
MANDATORY-GROUPS { ogBasicStatusGroup, ogBasicAlertStatusGroup }
::= { ogStatusCompliances 1 }
-- units of conformance
ogBasicStatusGroup OBJECT-GROUP
OBJECTS {
ogSerialPortStatusPort,
ogSerialPortStatusRxBytes,
ogSerialPortStatusTxBytes,
ogSerialPortStatusSpeed,
ogSerialPortStatusDCD,
ogSerialPortStatusDTR,
ogSerialPortStatusDSR,
ogSerialPortStatusCTS,
ogSerialPortStatusRTS,
ogSerialPortStatusLabel,
ogSerialPortActiveUsersPort,
ogSerialPortActiveUsersName,
ogSerialPortActiveUsersPortLabel,
ogRpcStatusName,
ogRpcStatusMaxTemp,
ogRpcStatusAlertCount,
ogEmdStatusName,
ogEmdStatusTemp,
ogEmdStatusHumidity,
ogEmdStatusAlertCount,
ogDioStatusName,
ogDioStatusType,
ogDioStatusDirection,
ogDioStatusState,
ogDioStatusCounter,
ogDioStatusTriggerMode
}
STATUS current
DESCRIPTION
"A collection of objects to retrieve Opengear statistics."
::= { ogStatusGroups 1 }
ogBasicAlertStatusGroup OBJECT-GROUP
OBJECTS {
ogSignalAlertStatusPort,
ogSignalAlertStatusLabel,
ogSignalAlertStatusSignalName,
ogSignalAlertStatusState,
ogEnvAlertStatusDevice,
ogEnvAlertStatusSensor,
ogEnvAlertStatusOutlet,
ogEnvAlertStatusValue,
ogEnvAlertStatusOldValue,
ogEnvAlertStatusStatus,
ogNutAlertStatusPort,
ogNutAlertStatusName,
ogNutAlertStatusHost,
ogNutAlertStatusStatus,
ogDataAlertStatusBytes,
ogDataAlertStatusSeconds,
ogDataAlertStatusDevice,
ogDataAlertStatusState,
ogDioAlertStatusName,
ogDioAlertStatusValue,
ogDioAlertStatusOldValue,
ogDioAlertStatusTriggered
}
STATUS current
DESCRIPTION
"A collection of objects to retrieve Opengear alert status."
::= { ogStatusGroups 2 }
END