-- Box Services MIB overview:
-- Box Services MIB falls under lb6m MIB node of the private subtree.
NETGEAR-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN
-- Netgear Inc NETGEAR Box Services MIB
-- Copyright Netgear Inc(2004-2008) All rights reserved.
-- This SNMP Management Information Specification
-- embodies Netgear Inc's confidential and proprietary
-- intellectual property. Netgear Inc retains all title
-- and ownership in the Specification including any revisions.
-- This Specification is supplied "AS IS", Netgear Inc
-- makes no warranty, either expressed or implied,
-- as to the use, operation, condition, or performance of the
-- Specification.
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Unsigned32, Integer32 FROM SNMPv2-SMI
TEXTUAL-CONVENTION FROM SNMPv2-TC
DisplayString FROM RFC1213-MIB
lb6m FROM QUANTA-LB6M-REF-MIB;
fastPathBoxServices MODULE-IDENTITY
LAST-UPDATED "201101260000Z" -- 26 Jan 2011 12:00:00 GMT
ORGANIZATION "Netgear Inc"
CONTACT-INFO ""
DESCRIPTION
"The Netgear Private MIB for NETGEAR Box Services Feature."
-- Revision history.
REVISION
"201101260000Z" -- 26 Jan 2011 12:00:00 GMT
DESCRIPTION
"Postal address updated."
REVISION
"200802220000Z" -- 22 Feb 2008 12:00:00 GMT
DESCRIPTION
"Netgear branding related changes."
::= { lb6m 43 }
BoxsTemperatureStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The temperature state"
SYNTAX INTEGER {
low(0),
normal(1),
warning(2),
critical(3),
shutdown(4),
notpresent(5),
notoperational(6)
}
--**************************************************************************************
-- boxServicesGroup
--
-- This group provides configuration and status of the Box Services
-- feature.
--
--**************************************************************************************
boxServicesGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 1 }
--**************************************************************************************
-- Some scalars
boxServicesNormalTempRangeMin OBJECT-TYPE
SYNTAX Integer32 (-100..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Lower boundary of normal temperature range."
DEFVAL { 0 }
::= { boxServicesGroup 1 }
boxServicesNormalTempRangeMax OBJECT-TYPE
SYNTAX Integer32 (-100..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Upper boundary of normal temperature range."
DEFVAL { 45 }
::= { boxServicesGroup 2 }
boxServicesTemperatureTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range"
DEFVAL { enable }
::= { boxServicesGroup 3 }
boxServicesPSMStateTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable or disable Power Supply Module state change trap."
DEFVAL { enable }
::= { boxServicesGroup 4 }
boxServicesFanStateTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Enable or disable Fan state change trap."
DEFVAL { enable }
::= { boxServicesGroup 5 }
boxServicesThermalShutdownSensor OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The number of the sensor which initiated thermal shutdown."
::= { boxServicesGroup 13 }
boxServicesThermalShutdownTemperature OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The temperature of the sensor which initiated thermal shutdown."
::= { boxServicesGroup 14 }
--**************************************************************************************
-- boxServicesFans
boxServicesFansTable OBJECT-TYPE
SYNTAX SEQUENCE OF BoxServicesFansEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fan"
::= { boxServicesGroup 6 }
boxServicesFansEntry OBJECT-TYPE
SYNTAX BoxServicesFansEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Box Services Fan Entry"
INDEX { boxServicesFanUnitIndex , boxServicesFansIndex }
::= { boxServicesFansTable 1 }
BoxServicesFansEntry ::= SEQUENCE {
boxServicesFanUnitIndex
Unsigned32,
boxServicesFansIndex
Integer32,
boxServicesFanItemType
INTEGER,
boxServicesFanItemState
INTEGER,
boxServicesFanSpeed
OCTET STRING,
boxServicesFanDutyLevel
OCTET STRING
}
boxServicesFanUnitIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit index for an entry in the Box Services Fan Table"
::= { boxServicesFansEntry 6 }
boxServicesFansIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index of fan table entry"
::= { boxServicesFansEntry 1 }
boxServicesFanItemType OBJECT-TYPE
SYNTAX INTEGER {
fixed(1),
removable(2),
fixedAC(3),
removableDC(4),
fixedDC(5),
removableAC(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of fan"
::= { boxServicesFansEntry 2 }
boxServicesFanItemState OBJECT-TYPE
SYNTAX INTEGER {
notpresent(1),
operational(2),
failed(3),
powering(4),
nopower(5),
notpowering(6),
incompatible(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of fan. nopower(4) - This state means the fan is present but no AC is connected."
::= { boxServicesFansEntry 3 }
boxServicesFanSpeed OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (13))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The speed of fan"
::= { boxServicesFansEntry 4}
boxServicesFanDutyLevel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (13))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The duty level of fan, in percents"
::= { boxServicesFansEntry 5}
--**************************************************************************************
-- boxServicesPowSupplies
boxServicesPowSuppliesTable OBJECT-TYPE
SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Power supply"
::= { boxServicesGroup 7 }
boxServicesPowSuppliesEntry OBJECT-TYPE
SYNTAX BoxServicesPowSuppliesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Box Services Power Supply Entry"
INDEX { boxServicesPowerSuppUnitIndex, boxServicesPowSupplyIndex }
::= { boxServicesPowSuppliesTable 1 }
BoxServicesPowSuppliesEntry ::= SEQUENCE {
boxServicesPowerSuppUnitIndex
Unsigned32,
boxServicesPowSupplyIndex
Integer32,
boxServicesPowSupplyItemType
INTEGER,
boxServicesPowSupplyItemState
INTEGER
}
boxServicesPowerSuppUnitIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit index for an entry in the Box Services Power Supply Table"
::= { boxServicesPowSuppliesEntry 4 }
boxServicesPowSupplyIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index of power supply table entry"
::= { boxServicesPowSuppliesEntry 1 }
boxServicesPowSupplyItemType OBJECT-TYPE
SYNTAX INTEGER {
fixed(1),
removable(2),
fixedAC(3),
removableDC(4),
fixedDC(5),
removableAC(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of power supply"
::= { boxServicesPowSuppliesEntry 2 }
boxServicesPowSupplyItemState OBJECT-TYPE
SYNTAX INTEGER {
notpresent(1),
operational(2),
failed(3),
powering(4),
nopower(5),
notpowering(6),
incompatible(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of power supply. nopower(5) - This state means the power supply is present but no AC is connected.
incompatible(7) - This state is possible on boards capable of pluggable Power supplies"
::= { boxServicesPowSuppliesEntry 3 }
--**************************************************************************************
-- boxServicesTempSensors
boxServicesTempSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Temperature sensor"
::= { boxServicesGroup 8 }
boxServicesTempSensorsEntry OBJECT-TYPE
SYNTAX BoxServicesTempSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Box Services Temperature Sensor Entry"
INDEX { boxServicesUnitIndex, boxServicesTempSensorIndex }
::= { boxServicesTempSensorsTable 1 }
BoxServicesTempSensorsEntry ::= SEQUENCE {
boxServicesUnitIndex
Unsigned32,
boxServicesTempSensorIndex
Unsigned32,
boxServicesTempSensorType
INTEGER,
boxServicesTempSensorState
BoxsTemperatureStatus,
boxServicesTempSensorTemperature
Integer32
}
boxServicesUnitIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit index for an entry in the Box Services Temperature Sensor Table"
::= { boxServicesTempSensorsEntry 1 }
boxServicesTempSensorIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index of temperature sensor table entry"
::= { boxServicesTempSensorsEntry 2 }
boxServicesTempSensorType OBJECT-TYPE
SYNTAX INTEGER {
fixed(1),
removable(2),
fixedAC(3),
removableDC(4),
fixedDC(5),
removableAC(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of temperature sensor"
::= { boxServicesTempSensorsEntry 3 }
boxServicesTempSensorState OBJECT-TYPE
SYNTAX BoxsTemperatureStatus
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The state of temperature sensor"
::= { boxServicesTempSensorsEntry 4 }
boxServicesTempSensorTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature value reported by sensor"
::= { boxServicesTempSensorsEntry 5 }
boxServicesTempUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF BoxServicesTempUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Temperature status table"
::= { boxServicesGroup 15 }
boxServicesTempUnitEntry OBJECT-TYPE
SYNTAX BoxServicesTempUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Box Services Temperature Unit Entry"
INDEX { boxServicesTempUnitIndex }
::= { boxServicesTempUnitTable 1 }
BoxServicesTempUnitEntry ::= SEQUENCE {
boxServicesTempUnitIndex
Unsigned32,
boxServicesTempUnitState
BoxsTemperatureStatus,
boxServicesTempUnitTemperature
Integer32
}
boxServicesTempUnitIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit index for an entry in the Box Services Temperature Unit Table"
::= { boxServicesTempUnitEntry 1 }
boxServicesTempUnitState OBJECT-TYPE
SYNTAX BoxsTemperatureStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature state of the unit"
::= { boxServicesTempUnitEntry 2 }
boxServicesTempUnitTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest temperature currently reported by any sensor on the unit"
::= { boxServicesTempUnitEntry 3 }
--**************************************************************************************
-- boxServicesNotificationsGroup
--
-- This group provides notification definitions for the Box Services
-- feature.
--
--**************************************************************************************
boxServicesNotificationsGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 2 }
--**************************************************************************************
-- boxServices notification definitions
boxsItemStateChangeEvent OBJECT-TYPE
SYNTAX INTEGER {
insertion(1),
removal(2),
becomeoperational(3),
failure(4),
losepower(5)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This event describes states of the fan or power supply.
insertion - hot-pluggable fan or power supply was inserted
removal - hot-pluggable fan or power supply was removed
becomeoperational - fan or power supply became operational after failure state
failure - fan or power supply failure happened, i.e. it is not able to perform its functions
losepower - a power supply was operational, but the power to it has been disconnected or has failed"
::= { boxServicesNotificationsGroup 1 }
boxsTemperatureChangeEvent OBJECT-TYPE
SYNTAX INTEGER {
abovethreshold(1),
belowthreshold(2),
withinnormalrange(3)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This event describes change of the temperature.
To avoid flipping on boundary conditions, it is allowed to send the trap
taking into account some margin around thresholds.
abovethreshold - temperature increased and crossed upper threshold value
belowthreshold - temperature decreased and crossed lower threshold value
withinnormalrange - temperature returned to normal range (between threshold)"
::= { boxServicesNotificationsGroup 2 }
boxsTemperatureStatusCurrentEvent OBJECT-TYPE
SYNTAX BoxsTemperatureStatus
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This event describes the current status of a switch."
::= { boxServicesNotificationsGroup 3 }
boxsTemperatureStatusPreviousEvent OBJECT-TYPE
SYNTAX BoxsTemperatureStatus
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This event describes the previous status of a switch."
::= { boxServicesNotificationsGroup 4 }
--**************************************************************************************
-- Traps
--**************************************************************************************
fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 }
boxsFanStateChange NOTIFICATION-TYPE
OBJECTS {
boxServicesFansIndex,
boxsItemStateChangeEvent
}
STATUS current
DESCRIPTION
"Trap is sent when fan state change happens."
::= { fastPathBoxServicesTraps 1 }
boxsPowSupplyStateChange NOTIFICATION-TYPE
OBJECTS {
boxServicesPowSupplyIndex,
boxsItemStateChangeEvent
}
STATUS current
DESCRIPTION
"Trap is sent when power supply state change happens."
::= { fastPathBoxServicesTraps 2 }
boxsTemperatureChange NOTIFICATION-TYPE
OBJECTS {
boxServicesTempSensorIndex,
boxsTemperatureChangeEvent
}
STATUS obsolete
DESCRIPTION
"Trap is sent when temperature is changing and crossing any of the thresholds"
::= { fastPathBoxServicesTraps 3 }
boxsThermalShutdown NOTIFICATION-TYPE
OBJECTS {
boxServicesThermalShutdownSensor,
boxServicesThermalShutdownTemperature
}
STATUS current
DESCRIPTION
"Trap is sent when thermal shutdown is initiated."
::= { fastPathBoxServicesTraps 4 }
boxsTemperatureStateChange NOTIFICATION-TYPE
OBJECTS {
boxServicesTempUnitIndex,
boxsTemperatureStatusCurrentEvent,
boxsTemperatureStatusPreviousEvent
}
STATUS current
DESCRIPTION
"Trap is sent when the system temperature crosses a threshold.
To avoid rapid flapping between states, a hysteresis may
be applied."
::= { fastPathBoxServicesTraps 5 }
--**************************************************************************************
-- Locator LED manage group
--
-- This group provides manage definitions for the Locator LED feature.
--
--**************************************************************************************
boxsLocatorLedConfigGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 4 }
boxsLocatorLedUnit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Spesifies unit number where Locator LED should blink on.
This is write-only value. It always returns '0' on request
if the Locator Led feature is supported."
::= { boxsLocatorLedConfigGroup 1 }
boxsLocatorLedTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates time period in seconds for Locator LED blinking.
The range is from 20 to 3600 seconds.
The dafault value is 20 seconds.
This is write-only value. It always returns '0' on request
if the Locator Led feature is supported."
DEFVAL { 20 }
::= { boxsLocatorLedConfigGroup 2 }
boxsLocatorLedEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Starts the Locator LED blinking.
If boxsLocatorLedUnit has not been set current(manager) unit number will be used.
If boxsLocatorLedTime has not been set default value(20 seconds) will be used.
This is write-only value. It always returns '0' on request
if the Locator Led feature is supported."
::= { boxsLocatorLedConfigGroup 3 }
END