-- ** Filename: PRVT-OEM1-PARAMS-MIB
|
|||
|
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
|
|||
|
-- ** Purpose: Private MIB
|
|||
|
-- *********************************************************************
|
|||
|
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
|
|||
|
-- WARNING:
|
|||
|
--
|
|||
|
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
|
|||
|
--
|
|||
|
-- This file is the property of BATM Advanced Communications.
|
|||
|
-- BATM Advanced Communications retains all title and
|
|||
|
-- ownership in the Specification, including any revisions.
|
|||
|
|
|||
|
-- BATM Advanced Communications grants all interested parties a non-exclusive
|
|||
|
-- license to use and distribute an unmodified copy of this
|
|||
|
-- Specification in connection with management of BATM Advanced Communications
|
|||
|
-- and Telco Systems<6D>products, and without fee, provided that the following
|
|||
|
-- conditions are met:
|
|||
|
-- 1. Redistributions of this specification must retain the above copyright
|
|||
|
-- notice, this list of conditions and the following disclaimer.
|
|||
|
-- 2. Redistributions in binary form must reproduce the above copyright
|
|||
|
-- notice, this list of conditions and the following disclaimer in the
|
|||
|
-- documentation and/or other materials provided with the distribution.
|
|||
|
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
|
|||
|
-- or promote products derived from this specification without specific prior written
|
|||
|
-- permission.
|
|||
|
--
|
|||
|
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
|
|||
|
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
|
|||
|
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
|
|||
|
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
|
|||
|
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
|
|||
|
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
|
|||
|
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
|
|||
|
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
|
|||
|
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
|
|||
|
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
|
|||
|
PRVT-OEM1-PARAMS-MIB DEFINITIONS ::= BEGIN
|
|||
|
|
|||
|
IMPORTS
|
|||
|
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
|
|||
|
|
|||
|
DisplayString FROM SNMPv2-TC
|
|||
|
|
|||
|
switch FROM PRVT-SWITCH-MIB;
|
|||
|
|
|||
|
prvtOem1ParamsMIB MODULE-IDENTITY
|
|||
|
LAST-UPDATED "200612270000Z"
|
|||
|
ORGANIZATION "BATM Advanced Communication"
|
|||
|
CONTACT-INFO
|
|||
|
|
|||
|
"BATM/Telco Systems Support team
|
|||
|
Email:
|
|||
|
For North America: techsupport@telco.com
|
|||
|
For North Europe: support@batm.de, info@batm.de
|
|||
|
For the rest of the world: techsupport@telco.com"
|
|||
|
|
|||
|
DESCRIPTION
|
|||
|
"Initial version. This MIB will provied a way to read
|
|||
|
specific device parameters"
|
|||
|
|
|||
|
-- Revision history.
|
|||
|
REVISION "200612270000Z"
|
|||
|
DESCRIPTION
|
|||
|
"Initial revision history"
|
|||
|
|
|||
|
|
|||
|
::= { switch 2110 }
|
|||
|
|
|||
|
-- MIB objects
|
|||
|
|
|||
|
prvtOem1ParamsObjects OBJECT IDENTIFIER ::= { prvtOem1ParamsMIB 1 }
|
|||
|
prvtOem1ParamsNotifications OBJECT IDENTIFIER ::= { prvtOem1ParamsMIB 2 }
|
|||
|
prvtOem1ParamsConformance OBJECT IDENTIFIER ::= { prvtOem1ParamsMIB 3 }
|
|||
|
|
|||
|
prvtSerialNumber OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Device serial number"
|
|||
|
::= { prvtOem1ParamsObjects 1 }
|
|||
|
|
|||
|
prvtAssemblyNumber OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Device assembly number"
|
|||
|
::= { prvtOem1ParamsObjects 2 }
|
|||
|
|
|||
|
prvtHardwareRevision OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Device hardware revision"
|
|||
|
::= { prvtOem1ParamsObjects 3 }
|
|||
|
|
|||
|
prvtSwitchRevision OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Switch revision"
|
|||
|
::= { prvtOem1ParamsObjects 4 }
|
|||
|
|
|||
|
prvtSwitchVersion OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Switch version"
|
|||
|
::= { prvtOem1ParamsObjects 5 }
|
|||
|
|
|||
|
prvtSwitchEdition OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Switch edition"
|
|||
|
::= { prvtOem1ParamsObjects 6 }
|
|||
|
|
|||
|
prvtSwitchRepair OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Switch repair"
|
|||
|
::= { prvtOem1ParamsObjects 7 }
|
|||
|
|
|||
|
prvtHardwareAddress OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Switch hardware address"
|
|||
|
::= { prvtOem1ParamsObjects 8 }
|
|||
|
|
|||
|
prvtCabinetRow OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Cabinet row location"
|
|||
|
::= { prvtOem1ParamsObjects 9 }
|
|||
|
|
|||
|
prvtCabinetColumn OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Cabinet column location"
|
|||
|
::= { prvtOem1ParamsObjects 10 }
|
|||
|
|
|||
|
prvtChassisVerticalDeviation OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Chassis vertical deviation location"
|
|||
|
::= { prvtOem1ParamsObjects 11 }
|
|||
|
|
|||
|
prvtChassisHorizontalDeviatioin OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Chassis horizontal deviation location"
|
|||
|
::= { prvtOem1ParamsObjects 12 }
|
|||
|
|
|||
|
prvtCabinetHMSNumber OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Cabinet HMS number"
|
|||
|
::= { prvtOem1ParamsObjects 13 }
|
|||
|
|
|||
|
prvtSubrackHMSNumber OBJECT-TYPE
|
|||
|
SYNTAX DisplayString
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Subrack HMS number"
|
|||
|
::= { prvtOem1ParamsObjects 14 }
|
|||
|
|
|||
|
prvtModelNumber OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Model number"
|
|||
|
::= { prvtOem1ParamsObjects 15 }
|
|||
|
|
|||
|
prvtPluginUID OBJECT-TYPE
|
|||
|
SYNTAX INTEGER
|
|||
|
MAX-ACCESS read-only
|
|||
|
STATUS current
|
|||
|
DESCRIPTION
|
|||
|
"Plugin UID"
|
|||
|
::= { prvtOem1ParamsObjects 16 }
|
|||
|