-- UBQS-ENTITY-MIB : Ubiquoss FRU Control MIB file
--
-- June 2009, Hyung Eun Park
--
-- Copyright (c) 2009 by Ubiquoss, Corp.
-- All rights reserved.
--
-- *****************************************************************
--
UBQS-ENTITY-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION,
DisplayString,
TimeStamp,
TruthValue
FROM SNMPv2-TC
entPhysicalIndex,
entPhysicalName,
entPhysicalDescr,
entPhysicalContainedIn
FROM ENTITY-MIB
ubiMgmtv2
FROM UBQS-SMI;
ubiEntityMIB MODULE-IDENTITY
LAST-UPDATED "200906160000Z"
ORGANIZATION "Ubiquoss Corp."
CONTACT-INFO
" Ubiquoss
Customer Service
Postal: 24F Milennium B/D,
467-12, Dogok-Dong,
GangNam-Gu, Seoul 135-270
Korea
Tel: 82-2-2190-3100"
DESCRIPTION
"The UBQS-ENTITY-MIB is used to monitor
and configure operational status of
Field Replaceable Units (FRUs) and other managable
physical entities of the system listed in the
Entity-MIB (RFC 2737) entPhysicalTable."
::= { ubiMgmtv2 3 }
-- ***********************************************************
-- TEXTUAL-CONVENTION
-- Define the composed syntax
-- ***********************************************************
ModuleOperType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Operational module states. Valid values are :
unknown(1) Module is not in one of other states
normal operational states:
ok(2) Module is operational.
disabled(3) Module is administratively disabled.
selfTest(6) Module is performing selfTest.
failure states:
failed(7) Module has failed due to some condition
not stated above.
dormant(12) Module is waiting for an external or
internal event to become operational.
"
SYNTAX INTEGER {
other(1),
ok(2),
disabled(3)
}
UbiSensorDataType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"sensor measurement data types. valid values are:
other(1): a measure other than those listed below
unknown(2): unknown measurement, or
arbitrary, relative numbers
volts(3): electric potential
amperes(4): electric current
celsius(5): temperature
dBm(6): dB relative to 1mW of power
percentRH(8): percent relative humidity
rpm(9): shaft revolutions per minute
cmm(10),: cubic meters per minute (airflow)
truthvalue(11): value takes { true(1), false(2) }
specialEnum(12): value takes user defined enumerated values
watts(13): power
hertz(14): frequency
"
SYNTAX INTEGER {
other(1),
unknown(2),
volts(3),
amperes(4),
celsius(5),
dBm(6),
percentRH(8),
rpm(9),
cmm(10),
truthvalue(11),
specialEnum(12),
watts(13),
hertz(14)
}
UbiSensorDataScale ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"International System of Units (SI) prefixes."
SYNTAX INTEGER {
yocto(1), -- 10^-24
zepto(2), -- 10^-21
atto(3), -- 10^-18
femto(4), -- 10^-15
pico(5), -- 10^-12
nano(6), -- 10^-9
micro(7), -- 10^-6
milli(8), -- 10^-3
units(9), -- 10^0
kilo(10), -- 10^3
mega(11), -- 10^6
giga(12), -- 10^9
tera(13), -- 10^12
exa(14), -- 10^15
peta(15), -- 10^18
zetta(16), -- 10^21
yotta(17) -- 10^24
}
UbiSensorPrecision ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"When in the range 1 to 9, SensorPrecision is the number
of decimal places in the fractional part of
a SensorValue fixed-point number. When in the range -8 to
-1, SensorPrecision is the number of accurate digits in
a SensorValue fixed-point number.
SensorPrecision is 0 for non-fixed-point numbers.
Agent implementors must choose a value for SensorPrecision
so that the precision and accuracy of a SensorValue is
correctly indicated.
For example, a temperature sensor that can measure 0o to
100o C in 0.1o increments, +/- 0.05o, would have a
SensorPrecision of 1, a SensorDataScale of units(0), and a
SensorValue ranging from 0 to 1000.
The SensorValue would be interpreted as (degrees C * 10).
If that temperature sensor's precision were 0.1o but its
accuracy were only +/- 0.5o, then the SensorPrecision would
be 0. The SensorValue would be interpreted as degrees C.
Another example: a fan rotation speed sensor that measures RPM
from 0 to 10,000 in 100 RPM increments, with an accuracy of
+50/-37 RPM, would have a SensorPrecision of -2, a
SensorDataScale of units(9), and a SensorValue ranging from 0
to 10000. The 10s and 1s digits of SensorValue would always
be 0.
"
SYNTAX INTEGER (-8..9)
UbiSensorValue_cisco ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"For sensors that measure voltsAC, voltsDC,
amperes, watts, hertz, celsius, cmm
this item is a fixed point number ranging from
-999,999,999 to +999,999,999. Use the value
-1000000000 to indicate underflow. Use the value
+1000000000 to indicate overflow. Use SensorPrecision
to indicate how many fractional digits the SensorValue
has.
For sensors that measure percentRH, this item
is a number ranging from 0 to 100.
For sensors that measure rpm, this item
can take only nonnegative values, 0..999999999.
For sensors of type truthvalue, this item
can take only two values: true(1), false(2).
For sensors of type specialEnum, this item
can take any value in the range (-1000000000..1000000000),
but the meaning of each value is specific to the
sensor.
For sensors of type other and unknown,
this item can take any value in the range
(-1000000000..1000000000), but the meaning of the values
are specific to the sensor.
Use Entity-MIB entPhysicalTable.entPhysicalVendorType
to learn about the sensor type.
"
SYNTAX INTEGER (-1000000000..1000000000)
UbiSensorValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represent the sensor value"
SYNTAX OCTET STRING
UbiTcIdentifier ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
""
SYNTAX INTEGER {
unknown(0),
other(1),
gbic(2),
module(3),
sfp(4),
xbi(5),
xenpak(6),
xfp(7),
xff(8),
xfp_e(9),
xpak(10),
x2(11)
}
UbiTcEncodingType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
""
SYNTAX INTEGER {
unknown(0),
other(1),
enc_64b(2),
enc_4b5b(3),
enc_8b10b(4),
enc_sonet(5),
enc_nrz(6),
enc_rz(7),
enc_manchester(8)
}
UbiTcConnectorType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
""
SYNTAX INTEGER {
unknown(0),
other(1),
sc(2),
fiber_style1_copper(3),
fiber_stype2_copper(4),
bnc_tnc(5),
fiber_coaxial(6),
fiberjack(7),
lc(8),
mt_rj(9),
sg(10),
optical_pigtail(11),
hssdc2(12),
copper_pigtail(13)
}
-- ***********************************************************
-- ubiEntityMIB
-- ***********************************************************
ubiEntityMIBObjects OBJECT IDENTIFIER ::= { ubiEntityMIB 1 }
ubiEntityMIBNotificationPrefix OBJECT IDENTIFIER ::= { ubiEntityMIB 2 }
ubiEntityMIBConformance OBJECT IDENTIFIER ::= { ubiEntityMIB 3 }
ubiEntityNotificationEnables OBJECT IDENTIFIER ::= { ubiEntityMIBObjects 1 }
ubiExtSlot OBJECT IDENTIFIER ::= { ubiEntityMIBObjects 4 }
ubiTransceiver OBJECT IDENTIFIER ::= { ubiEntityMIBObjects 5 }
ubiFruNotifications OBJECT IDENTIFIER ::= { ubiEntityMIBNotificationPrefix 0 }
ubiEntitySensorNotifications OBJECT IDENTIFIER ::= { ubiEntityMIBNotificationPrefix 1 }
-- ***********************************************************
-- ubiEntityEnableFruControlNotification
-- ***********************************************************
ubiFRUControlEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates whether the system
produces the following notifications:
ubiEntityFRUInserted, ubiEntityFRURemoved.
A false value will prevent these notifications
from being generated."
DEFVAL { false }
::= { ubiEntityNotificationEnables 1 }
ubiEntSensorThresholdNotificationEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates whether the system
produces the following notification:
ubiEntSensorThreshold.
A false value will prevent these notifications
from being generated."
DEFVAL { false }
::= { ubiEntityNotificationEnables 2 }
-- ***********************************************************
-- ubiEntityModuleTable
-- ***********************************************************
ubiModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF UbiModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per module entity."
::= { ubiEntityMIBObjects 2 }
ubiModuleEntry OBJECT-TYPE
SYNTAX UbiModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular module entity."
INDEX { entPhysicalIndex }
::= { ubiModuleTable 1 }
UbiModuleEntry ::= SEQUENCE {
ubiModuleId INTEGER,
ubiModuleType DisplayString,
ubiModuleOperStatus ModuleOperType,
ubiModuleStatusLastChangeTime TimeStamp,
ubiModuleSerialNumber DisplayString,
ubiModuleSlotNumber Integer32,
ubiModulePortNumber Integer32,
ubiModuleAction INTEGER,
}
ubiModuleId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique module ID."
::= { ubiModuleEntry 1 }
ubiModuleType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The textual type of this module."
::= { ubiModuleEntry 2 }
ubiModuleOperStatus OBJECT-TYPE
SYNTAX ModuleOperType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational state of this module."
::= { ubiModuleEntry 3 }
ubiModuleStatusLastChangeTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when ubiModuleOperStatus
is changed."
::= { ubiModuleEntry 4 }
ubiModuleSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of this module."
::= { ubiModuleEntry 5 }
ubiModuleSlotNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is determined by the number of slot
where the module is located."
::= { ubiModuleEntry 6 }
ubiModulePortNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is determined by the number of port
where the module is located."
::= { ubiModuleEntry 7 }
ubiModuleAction OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object, when read, returns one of the
following results:
other(1): module permanently enabled
Setting this object to one of the acceptable values
gives the following results:
other(1): gives an error
reset(2): resets the module's control logic
Setting this object to any other values results in
an error."
::= { ubiModuleEntry 8 }
-- ***********************************************************
-- ubiSlotEntity
-- ***********************************************************
ubiSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF UbiSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per slot entity."
::= { ubiEntityMIBObjects 3 }
ubiSlotEntry OBJECT-TYPE
SYNTAX UbiSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular slot entity."
INDEX { entPhysicalIndex }
::= { ubiSlotTable 1 }
UbiSlotEntry ::= SEQUENCE {
ubiSlotModuleId INTEGER,
ubiSlotId INTEGER,
ubiSlotType DisplayString,
ubiSlotOperStatus ModuleOperType,
ubiSlotPortNumber Integer32,
ubiSlotSerialNumber DisplayString
}
ubiSlotModuleId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique module ID."
::= { ubiSlotEntry 1 }
ubiSlotId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique slot ID."
::= { ubiSlotEntry 2 }
ubiSlotType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The textual type of this slot."
::= { ubiSlotEntry 3 }
ubiSlotOperStatus OBJECT-TYPE
SYNTAX ModuleOperType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this slot."
::= { ubiSlotEntry 4 }
ubiSlotPortNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is determined by the number of port
where the slot is located."
::= { ubiSlotEntry 5 }
ubiSlotSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The serial number of this slot."
::= { ubiSlotEntry 6 }
-- ***********************************************************
-- ubiExtSlotTable
-- ***********************************************************
ubiIEEE1588SlotOperStatus OBJECT-TYPE
SYNTAX INTEGER {
equip(1),
unequip(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational status of the slot for
IEEE 1588 specification."
::= { ubiExtSlot 1 }
ubiMngSlotOperStatus OBJECT-TYPE
SYNTAX INTEGER {
equip(1),
unequip(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational status of the slot for
mng specification."
::= { ubiExtSlot 2 }
-- ***********************************************************
-- ubiTransceiver
-- ***********************************************************
ubiTransceiverMonitoring OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates whether the system produces
the log and notification for transceiver sensor."
::= { ubiTransceiver 3 }
-- ***********************************************************
-- ubiEntitySensorTable
-- ***********************************************************
ubiEntitySensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF UbiEntitySensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects which provide information
about the transceiver sensor of physical entity."
::= { ubiTransceiver 1 }
ubiEntitySensorEntry OBJECT-TYPE
SYNTAX UbiEntitySensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable
to the transceiver sensor of a particular physical entity."
INDEX { entPhysicalIndex }
::= { ubiEntitySensorTable 1 }
UbiEntitySensorEntry ::= SEQUENCE {
ubiEntSensorType UbiSensorDataType,
ubiEntSensorScale UbiSensorDataScale,
ubiEntSensorValue UbiSensorValue,
ubiEntSensorEventStatus INTEGER,
ubiEntSensorEventUpdateTime TimeStamp,
ubiEntSensorAlarmHighThreshold UbiSensorValue,
ubiEntSensorWarningHighThreshold UbiSensorValue,
ubiEntSensorWarningLowThreshold UbiSensorValue,
ubiEntSensorAlarmLowThreshold UbiSensorValue,
--ubiEntSensorPrecision UbiSensorPrecision,
ubiEntSensorName DisplayString
}
ubiEntSensorType OBJECT-TYPE
SYNTAX UbiSensorDataType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the type of data reported
by the entSensorValue.
valid values are:
other(1): a measure other than those listed below
unknown(2): unknown measurement, or
arbitrary, relative numbers
voltsAC(3): electric potential
voltsDC(4): electric potential
amperes(5): electric current
celsius(6): temperature
dBm(7): dB relative to 1mW of power
"
::= { ubiEntitySensorEntry 1 }
ubiEntSensorScale OBJECT-TYPE
SYNTAX UbiSensorDataScale
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the exponent to apply
to sensor values reported by entSensorValue."
::= { ubiEntitySensorEntry 2 }
-- ubiEntSensorPrecision OBJECT-TYPE
-- SYNTAX UbiSensorPrecision
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- ""
-- ::= { ubiEntitySensorEntry 3 }
ubiEntSensorValue OBJECT-TYPE
SYNTAX UbiSensorValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable reports the most recent measurement seen
by the sensor."
::= { ubiEntitySensorEntry 3 }
ubiEntSensorEventStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0),
normal(1),
highAlarm(2),
highWarning(3),
lowWarning(4),
lowAlarm(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the present
current event status of the sensor."
::= { ubiEntitySensorEntry 4 }
ubiEntSensorEventUpdateTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the status of
entity sensor is changed."
::= { ubiEntitySensorEntry 5 }
ubiEntSensorAlarmHighThreshold OBJECT-TYPE
SYNTAX UbiSensorValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates the value of
the high alarm threshold."
::= { ubiEntitySensorEntry 6 }
ubiEntSensorWarningHighThreshold OBJECT-TYPE
SYNTAX UbiSensorValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates the value of
the high warning threshold."
::= { ubiEntitySensorEntry 7 }
ubiEntSensorWarningLowThreshold OBJECT-TYPE
SYNTAX UbiSensorValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates the value of
the low warning threshold."
::= { ubiEntitySensorEntry 8 }
ubiEntSensorAlarmLowThreshold OBJECT-TYPE
SYNTAX UbiSensorValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates the value of
the low alarm threshold."
::= { ubiEntitySensorEntry 9 }
ubiEntSensorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the name of
the sensor entity."
::= { ubiEntitySensorEntry 10 }
-- ***********************************************************
-- ubiTransceiverInfoTable
-- ***********************************************************
ubiTransceiverInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF UbiTransceiverInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects which provide information
about the transceiver of physical entity."
::= { ubiTransceiver 2 }
ubiTransceiverInfoEntry OBJECT-TYPE
SYNTAX UbiTransceiverInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable
to the transceiver of a particular physical entity."
INDEX { entPhysicalIndex }
::= { ubiTransceiverInfoTable 1 }
UbiTransceiverInfoEntry ::= SEQUENCE {
ubiTcIdentifier UbiTcIdentifier,
ubiTcVendorOUI DisplayString,
ubiTcVendorName DisplayString,
ubiTcVendorPartNumber DisplayString,
ubiTcVendorRevisionLevel DisplayString,
ubiTcVendorSerialNumber DisplayString,
ubiTcVendorManufacturingDate DisplayString,
ubiTcWaveLength Integer32,
ubiTcConnector UbiTcConnectorType,
ubiTcLength Integer32,
}
ubiTcIdentifier OBJECT-TYPE
SYNTAX UbiTcIdentifier
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the transceiver indentifier.
valid value are:
unknown(0),
other(1),
gbic(2),
module(3),
sfp(4),
xbi(5),
xenpak(6),
xfp(7),
xff(8),
xfp_e(9),
xpak(10),
x2(11)
"
::= { ubiTransceiverInfoEntry 1 }
ubiTcVendorOUI OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates a textual string containing
information about the IEEE company ID of transceiver vendor"
::= { ubiTransceiverInfoEntry 2 }
ubiTcVendorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the
transceiver name."
::= { ubiTransceiverInfoEntry 3 }
ubiTcVendorPartNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the
part number of the transceiver."
::= { ubiTransceiverInfoEntry 4 }
ubiTcVendorRevisionLevel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the
revision level of the transceiver part number."
::= { ubiTransceiverInfoEntry 5 }
ubiTcVendorSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates a textual string containing
information about the transceiver serial number."
::= { ubiTransceiverInfoEntry 6 }
ubiTcVendorManufacturingDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates a manufacturing date
of transceiver"
::= { ubiTransceiverInfoEntry 7 }
ubiTcWaveLength OBJECT-TYPE
SYNTAX Integer32
UNITS "Nanometer"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates a wave length
of transceiver."
::= { ubiTransceiverInfoEntry 8 }
ubiTcConnector OBJECT-TYPE
SYNTAX UbiTcConnectorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates a connector type
of transceiver."
::= { ubiTransceiverInfoEntry 9 }
ubiTcLength OBJECT-TYPE
SYNTAX Integer32
UNITS "Meter"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates a length
of transceiver."
::= { ubiTransceiverInfoEntry 10 }
-- ***********************************************************
-- ubiEntityFRUMIBNotificationPrefix
-- ***********************************************************
ubiFRUInserted NOTIFICATION-TYPE
OBJECTS {
entPhysicalContainedIn,
entPhysicalDescr,
entPhysicalName
}
STATUS current
DESCRIPTION
"The ubiEntityFRUInserted notification indicates that a FRU was
inserted. The varbind for this notification indicates the
entPhysicalIndex of the inserted FRU, and the entPhysicalIndex
of the FRU's container."
::= { ubiFruNotifications 1 }
ubiFRURemoved NOTIFICATION-TYPE
OBJECTS {
entPhysicalContainedIn,
entPhysicalDescr,
entPhysicalName
}
STATUS current
DESCRIPTION
"The ubiEntityFRURemoved notification indicates that a FRU was
removed. The varbind for this notification indicates the
entPhysicalIndex of the removed FRU, and the entPhysicalIndex
of the FRU's container."
::= { ubiFruNotifications 2 }
-- ***********************************************************
-- ubiDdmMIBNotificationPrefix
-- ***********************************************************
ubiEntSensorThreshold NOTIFICATION-TYPE
OBJECTS {
entPhysicalDescr,
ubiEntSensorEventStatus,
ubiEntSensorValue,
ubiEntSensorAlarmHighThreshold,
ubiEntSensorWarningHighThreshold,
ubiEntSensorWarningLowThreshold,
ubiEntSensorAlarmLowThreshold,
}
STATUS current
DESCRIPTION
"The ubiEntSensorThreshold notification indicates that
the status of transceiver sensor was changed."
::= { ubiEntitySensorNotifications 1 }
-- ***********************************************************
-- ubiEntityMIBConformance
-- ***********************************************************
-- conformance information
ubiEntityMIBCompliances OBJECT IDENTIFIER ::= { ubiEntityMIBConformance 1 }
ubiEntityMIBGroups OBJECT IDENTIFIER ::= { ubiEntityMIBConformance 2 }
--
-- compliance statements
--
ubiEntityMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"An Entity-MIB implementation can implement this group to
provide FRU status and control."
MODULE -- this module
MANDATORY-GROUPS {
ubiEntityMIBModuleGroup,
ubiEntityMIBSlotGroup,
ubiEntityMIBNotificationGroup,
ubiEntiryMIBIEEE1588SlotGroup,
ubiEntityMIBTransceiverGroup
}
GROUP ubiEntityMIBModuleGroup
DESCRIPTION
"The ubiEntityMIBModuleGroup must be implemented for
FRUs that are of module type."
GROUP ubiEntityMIBSlotGroup
DESCRIPTION
"The ubiEntityMIBSlotGroup must be
implemented for FRUs that of slot type"
GROUP ubiEntityMIBNotificationGroup
DESCRIPTION
"The ubiEntityMIBNotificationGroup must be
implemented for FRUs that have notification"
GROUP ubiEntiryMIBIEEE1588SlotGroup
DESCRIPTION
"The ubiEntiryMIBIEEE1588SlotGroup must be
implemented for FRUs that of slot for
IEEE 1588 specification."
GROUP ubiEntityMIBTransceiverGroup
DESCRIPTION
"The ubiEntityMIBTransceiverGroup must be implemented
for transceiver."
::= { ubiEntityMIBCompliances 1 }
-- units of conformance
ubiEntityMIBModuleGroup OBJECT-GROUP
OBJECTS {
ubiEntityModuleAdminStatus,
ubiEntityModuleOperStatus,
ubiEntityModuleStatusLastChangeTime
}
STATUS current
DESCRIPTION
"The collection of objects which are used to get the
operational state and redundancy state of the modules"
::= { ubiEntityMIBGroups 1 }
ubiEntitySlotGroup NOTIFICATION-GROUP
NOTIFICATIONS { ubiEntitySlotOperStatus }
STATUS current
DESCRIPTION
"The collection of objects which are used to get the
operational state and redundancy state of the slot."
::= { ubiEntityMIBGroups 2 }
ubiEntityMIBNotificationGroup OBJECT-GROUP
OBJECTS {
ubiEntityEnableFruControlNotification,
ubiEntityFRUInserted,
ubiEntityFRURemoved
}
STATUS current
DESCRIPTION
"TThe collection of objects which are
used to send a notification."
::= { ubiEntityMIBGroups 3 }
ubiEntiryMIBIEEE1588SlotGroup OBJECT-GROUP
OBJECTS {
ubiIEEE1588SlotOperStatus
}
STATUS current
DESCRIPTION
"The collection of objects which are used to get the
operational state of the slot for IEEE 1588."
::= { ubiEntityMIBGroups 4 }
ubiEntityMIBTransceiverGroup OBJECT-GROUP
OBJECTS {
ubiEntSensorType,
ubiEntSensorScale,
ubiEntSensorValue,
ubiEntSensorEventStatus,
ubiEntSensorEventUpdateTime,
ubiEntSensorAlarmHighThreshold,
ubiEntSensorWarningHighThreshold,
ubiEntSensorWarningLowThreshold ,
ubiEntSensorAlarmLowThreshold,
ubiTcIdentifier,
ubiTcVendorOUI,
ubiTcVendorName,
ubiTcVendorPartNumber,
ubiTcVendorRevisionLevel,
ubiTcVendorSerialNumber,
ubiTcVendorManufacturingDate,
ubiTcWaveLength ,
ubiTcConnector,
ubiTcLength
}
STATUS current
DESCRIPTION
"The collection of objects which are used to get the
information of transceiver."
::= { ubiEntityMIBGroups 5 }
END